HomeMy WebLinkAboutAPPROVED DM 5V PRODUCT APPROVAL2115/2021 Florida Building Code Online
r
zr. ^wY1
BCIS Home Log In User rReglstrateon Hot Topics j Submit Surcharge StaLs Facts ; Publications Cpntact Us i, BCIS Site Map Links ', Search J.
b
c3
01i
Product Approval
US>:R: Public User
Product Approval Menu > Product or ApyliL3tian Search > 64gplication List > Application Detail
FL #
*L27499-R3
�..�'._ Application Type FP YP
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer ynamic Metals
Address/phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category %k>R fing
Subcategory 'XMetal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A. Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
F 7499 R3 COI Dyn_COI.t f
Standard
Year
TAS 100
1995
TAS 110
2000
TAS 125
2003
https://www.floridabuilding,org/pr/pr_app-.dtl.aSPXPAram=wGEVXQwtDauHUlr2Ywe'/7hCzc('AnAREi-1ei9nvnnanc-)FOi-)furoiAlAWn.,---....I.._..n^..-,., .11
2/15/2021 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page 0
12/17/2020
12/19/2020
12/26/2020
02/09/2021
0 4 Page 1/ 2 0 4)
FL #
Modei, Number or Name
Description
Z7499.1
DM Class 1000 1" Nailstrip
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
_
snap fit seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
FL27499 R3 II N5516HZ pdf
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Evall.pdf
Created by Independent Third Party: Yes
27499.2
DM Class 1000 1" Nailstrip,
..032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Limits of Use
Installation Instructions
I
Approved for use in HVHZ: Yes
FL27499 R3 II NSA16HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eva] report for Limits of Use.
FL27499 R3 AE DM Eval2 pdf
Created by Independent Third Party: Yes
27499.3 DM Class 1050 1 1/2" Nailstrip
�
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
_
Limits of Use
seams.
Installation Instructions
Approved for use in HVHZ: Yes
]Evaluation
FL27499 R3 II NSA19H pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Eva[3 pdf
_
Created by Independent Third Party: Yes i
27499.4
DM Class 1050 1 1/2" Nailstrip
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL27499 R3 II NSSI9HZ pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
i
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports j
Other: Please see Eva] report for Limits of Use.
FL27499 R3 AE DM Eva14 pdf
_ ]Created
by Independent Third Party: Yes
27499.5
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II DM Dwg52.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
i
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval Report for Dmits of Use.
FL27499 R3 AE DM Eva152 pdf i
_
Created by Independent Third Party: Yes
27499.6
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with I" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL27499 R3 II DM Dwg62.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL27499 83 AE DM Eva]62 pdf
Limits of Use. _
Created by Independent Third Party: Yes
27499.7
DM Class 1150 1" Mechanical Seam
26. Ga. Galvalume coated steel roof panel, 21" wide, with 1"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II DM Dwg72.ndf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
https:gwww.floridabui]ding.org/pdpr_app dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCenABo3%2hkMR°G2f^7,2fun VJAV0 ,..—,. j—..on..,o1, „�
2/15/2021
Florida Building Code Online
Impact Resistant: N/A
Created by independent Third Party, Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL27499 R3 AE DM Eval72.pdf
Limits of Use,
f Crated by Independent Third Party: Yes
127499.8 1 DM Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 20" wide, with 1 1/2" standing
Seam seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II 1SMSA 0H2 pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes i
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Evaliipdf
Created by Independent Third Party: Yes
27499.9 I DM Class 1500 1 1/2" Mechanical 116 oz. Copper roof panel, 16" wide, with 1 1/2" standing
Seam seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 II 15MSCHZ,pjaf
Approved for use outside HVHZ: Yes I Verified By: Scott Wolters 62354
Impact Resistant: N/A ! Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports 1
Other: Please see Eval report for Limits of Use. FL27499 R3 AE DM Eva[9.pdf 1
Created by Independent Third Party: Yes
27499.10 DM Class 1500 1 1/2" Mechanical ( 26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
1 __ _._.. Seam standing seams. I
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II 15MSS16 6HZ pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Crated by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eva[ report for Limits of Use.
FL27499 R3 AE DM Eva110 pdf
Created by Independent Third Party: Yes
27499.11 Se Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 16" wide,,with 1 1/2" standing I
Seam seams. i
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 II 15MSA16HZ pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. I FL27499 R3 AE DM Eval11 pdf
Created by Independent Third Party: Yes
27499.12 IDM am24 Ga. dass 1500 1 1/2" Mechanical I stanng seams. S coated steel roof panel, 16" wide, with 1 1/2"
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eva] report for Limits of Use.
27499.13 DM Class 1500 1 1/2" Mechanical
Seam,
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
27499.14 DM Class 1750 1 3/4" Snaplock
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation instructions
FL27499 R3 IT ISMS516HZ pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R3 AE DM Eva]12.pdf
Created by Independent Third Party: Yes
24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2"
standing seams.
installation Instructions
FL27499 R3 II 15MSS20HZ pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 93 AE DM Eva113 pAf
Created by Independent Third Party: Yes
24 Ga. Galvalume coated steel roof panel, 18" wide, with 1
3/4" Snaplock seems, attached to metal deck.
Installation Instructions
FL27499 R3 II SLSI8BDH2 pdf
Verified By: Scott Wolters, P.E. FLPE4 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 93 AE DM E a1j4 {Ldf
Created by Independent Third Party: Yes
27499,15 DM Class 1750 1 3/4" Snaplock .032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams, attached to metal deck.
https://www.floridabuilding.org/pripr app_dtl.aspx?param=wGEVXQvdDquHOE2Ywe%2bOsCeDABo3%2hkM8^/2f"/
2/15/2021
Florida Building Code Online
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II SLAI8BDHZ pdf
1 Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eva[ report for Limits of Use.
FL27499 R3 AE DM EvallS.pdf
Created by Independent Third Party: Yes
27499.16
DM Class 1750 1 3/4- Snaplock
.032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II SLAI8HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes l
Design Pressure: N/A
Evaluation Reports
Other; Please see Eva[ report for Limits of Use.
FL27499 R3 AE DM Eva]16 pdf
Created by Independent Third Party: Yes
27499.17
DM Class 1750 1 3/4" Snaplock
24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4"
Snaplock seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II SLS18H2 pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eva[ report for Limits of Use.
FL27499 R3 AE DM Eva117.pdf
Created by Independent Third Party: Yes
II�27499.18
DM Class 2000 2" Mechanical Seam
.032 Aluminum roof panel, 18" wide, with 2" standing seams.
IILimits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II 2MSA18HZ pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure; N/A
Evaluation Reports
Other: Please see Eva] report for Limits of Use.
FL27499 R3 AE DM Eva118 pdf
Created by Independent Third Party: Yes
27499.19 DM Class 2000 2" Mechanical Seam
24 Ga. galvalume coated steel roof panel, 18" wide, with 2" .
Lstanding
—
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II 2MSS18HZ.p-df
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Evall9.pdf
Created by Independent Third Party: Yes
27499.20
DM Class 500 5V Crimp
26 Ga. galvalume coated steel roof panel, 24" wide, with Sv
crimp.
Limits of Use
Installation Instructions
Approved for use in HVHZ; Yes
FL27499 R3 II DM Dwg20.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other; Please see Eva[ report for Limits of Use.
FL27499 R3 AE DM Eval2tipdf
Created by Independent Third Party: Yes
Go to Page 14
m
Contact Us :: 2601 Bloir Stone Road, Tallahassee F132399 Phone, 850-487-1824
The State of Florida is an A vEEO employer. g,gl; M 200>-2013 State f FI id :: Privacy statement :: Aaessibiiity Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this endty- Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to section 455.275(I),
Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
product Approval Accepts:
® of ht[Y
https:llwww.floridabuilding,orglprlpr app_Atf.aspx?param=wGEVXQvADauHOE2Ywe%2bOsCenABnlp/2hkMr-A9PI9fKTPWAI<Cl,.. n.n.ln„.on,.,orz nlc
2/15/2021
Florida Building Code Online
Credit Card
Sate
https://w .floridabUilding.om/pr/pr app dfl.asox?oaraM-wGEVXOwron,]HOF9vwp.049hn�cPnna„ailhlllloI IM 1�11Aievo ............. ..........o.� �,�
WOLTERS ENGINEERING
ENGINEERING. DRAFTING, CONSULTING
15211 97th Road N
West Palm Beach, FL 33412
Ph1Fx:t561) 225-1982
1071 ymm-agn
gleam
RODUCT: DM CLASS 500 26 GA, GALVALUME 5V CRIMP 24" WIDE
ROOF PANEL (FLPA# 27499.20)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM Class 500 Series 26 Ga, Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507.4 and 1518.9 of the Th Edition (2020) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004-
02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "5VS-HZ° dated 8/15/19, signed and sealed by Scott Wolters, PE.
2, Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary
R Priest, PE.
4, Supplemental Calculations to support °5VS-HZ" drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 24" (nominal)
Fastener Spacing across panel: 12" (at Overlaps & Center Rib)
Min, Slope: HVHZ: 2712"
Non-HVHZ: %112° (with Lap Sealant)
3"112" (no Lap Sealant)
C�CIALI?I�i IN Ihtl'�'i I'' :15'!%1N� C,UP'iA,INWrI,i-5, . 0�,::FpON'C5, g vilN�;lWS
Field
Perimeter & Corner
Installation
Installation
_Max. Design Pressure:
117.75 psf
_ _
-206 psf
Fastener Spacing:
4" From Ends, 16" Max. O.C.
4" From Ends, 8" Max. O.C.
Min Panel Fasteners:
#10x1 /2' HiLo HWH Screw
_
#10x1 %' HE HWH Screw
with Weather -seal Washer
with Weather -seal Washer
Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current
fire directory listing for fire ratings of this roofing system assembly as well
as the location of the fire barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ, 1" round plastic caps meeting the requirements of
FBC Section 1507.1.1.1, may be used to prevent galvanic reactions.
Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section
1507.1.1.1 (min).
(or)
Any underlayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, V round plastic caps meeting the requirements of
FBC Section 1507.1.1.1 may be used to prevent galvanic reactions.
Minimum Substrate: l' (15/32" min) 4-ply CDX Plywood or 3/d' solid wood planks S.G. _ .42
min, nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
"�QN..171NG iN IPA 'C1 `15"U" Q1�rAINWA > �;O rpO'7t5 & N.�, SOWS
4. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
5. Where required by the Florida Building Code, panels shall be
permanently labeled with the manufacturer's name and/or logo, and the
following statement, "Dynamic Metals FL #27499.20, DM Class 500".
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 31d party QA provider, to the dimensions shown on Drawing 5VS-HZ:
SSQ-6800617 SSQ-5150216 SSQ-6810617
SSQ-6690517 SSQ-4560615 SSQ2-2310920
5VC-0490718 5VC-0360516 SSQ2-2320920
Re -Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel
may be installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1511 of the Florida Building Code.
If ,you have any questions or need more information concerning this approval, please contact me.
Thank you,
y ®rh-
Y�lc S235a
Scot�
FLPE#62354 `
�, STA7.E ' CCa
:;fiw3 %�2� y-�. of •`u��
FCI,N,l/IN6IN hA
171�1 931=
- ---------
4p
-- ---------
----- ------
� .v.��\\