Loading...
HomeMy WebLinkAboutAPPROVED DM 5V PRODUCT APPROVAL2115/2021 Florida Building Code Online r zr. ^wY1 BCIS Home Log In User rReglstrateon Hot Topics j Submit Surcharge StaLs Facts ; Publications Cpntact Us i, BCIS Site Map Links ', Search J. b c3 01i Product Approval US>:R: Public User Product Approval Menu > Product or ApyliL3tian Search > 64gplication List > Application Detail FL # *L27499-R3 �..�'._ Application Type FP YP Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer ynamic Metals Address/phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772)872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category %k>R fing Subcategory 'XMetal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code F 7499 R3 COI Dyn_COI.t f Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 https://www.floridabuilding,org/pr/pr_app-.dtl.aSPXPAram=wGEVXQwtDauHUlr2Ywe'/7hCzc('AnAREi-1ei9nvnnanc-)FOi-)furoiAlAWn.,---....I.._..n^..-,., .11 2/15/2021 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page 0 12/17/2020 12/19/2020 12/26/2020 02/09/2021 0 4 Page 1/ 2 0 4) FL # Modei, Number or Name Description Z7499.1 DM Class 1000 1" Nailstrip 26 Ga. galvalume coated steel roof panel, 16" wide, with 1" _ snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL27499 R3 II N5516HZ pdf Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R3 AE DM Evall.pdf Created by Independent Third Party: Yes 27499.2 DM Class 1000 1" Nailstrip, ..032" Aluminum roof panel, 16" wide, with 1" snap fit seams. Limits of Use Installation Instructions I Approved for use in HVHZ: Yes FL27499 R3 II NSA16HZ.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva] report for Limits of Use. FL27499 R3 AE DM Eval2 pdf Created by Independent Third Party: Yes 27499.3 DM Class 1050 1 1/2" Nailstrip � .032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit _ Limits of Use seams. Installation Instructions Approved for use in HVHZ: Yes ]Evaluation FL27499 R3 II NSA19H pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Reports Other: Please see Eval report for Limits of Use. FL27499 R3 AE DM Eva[3 pdf _ Created by Independent Third Party: Yes i 27499.4 DM Class 1050 1 1/2" Nailstrip 24 Ga. Galvalume coated steel roof panel, 19" wide, with 1 1/2" snap fit seams Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL27499 R3 II NSSI9HZ pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354 i Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports j Other: Please see Eva] report for Limits of Use. FL27499 R3 AE DM Eva14 pdf _ ]Created by Independent Third Party: Yes 27499.5 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II DM Dwg52.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 i Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval Report for Dmits of Use. FL27499 R3 AE DM Eva152 pdf i _ Created by Independent Third Party: Yes 27499.6 DM Class 1150 1" Mechanical Seam .032" Aluminum roof panel, 21" wide, with I" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: No FL27499 R3 II DM Dwg62.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499 83 AE DM Eva]62 pdf Limits of Use. _ Created by Independent Third Party: Yes 27499.7 DM Class 1150 1" Mechanical Seam 26. Ga. Galvalume coated steel roof panel, 21" wide, with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II DM Dwg72.ndf Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394 https:gwww.floridabui]ding.org/pdpr_app dtl.aspx?param=wGEVXQwtDquHOE2Ywe%2bOsCenABo3%2hkMR°G2f^7,2fun VJAV0 ,..—,. j—..on..,o1, „� 2/15/2021 Florida Building Code Online Impact Resistant: N/A Created by independent Third Party, Yes Design Pressure: N/A Evaluation Reports Other: Please see Installation Drawings and Eval Report for FL27499 R3 AE DM Eval72.pdf Limits of Use, f Crated by Independent Third Party: Yes 127499.8 1 DM Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 20" wide, with 1 1/2" standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II 1SMSA 0H2 pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes i Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R3 AE DM Evaliipdf Created by Independent Third Party: Yes 27499.9 I DM Class 1500 1 1/2" Mechanical 116 oz. Copper roof panel, 16" wide, with 1 1/2" standing Seam seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II 15MSCHZ,pjaf Approved for use outside HVHZ: Yes I Verified By: Scott Wolters 62354 Impact Resistant: N/A ! Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports 1 Other: Please see Eval report for Limits of Use. FL27499 R3 AE DM Eva[9.pdf 1 Created by Independent Third Party: Yes 27499.10 DM Class 1500 1 1/2" Mechanical ( 26 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2" 1 __ _._.. Seam standing seams. I Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II 15MSS16 6HZ pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Crated by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R3 AE DM Eva110 pdf Created by Independent Third Party: Yes 27499.11 Se Class 1500 1 1/2" Mechanical .032" Aluminum roof panel, 16" wide,,with 1 1/2" standing I Seam seams. i Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II 15MSA16HZ pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. I FL27499 R3 AE DM Eval11 pdf Created by Independent Third Party: Yes 27499.12 IDM am24 Ga. dass 1500 1 1/2" Mechanical I stanng seams. S coated steel roof panel, 16" wide, with 1 1/2" Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eva] report for Limits of Use. 27499.13 DM Class 1500 1 1/2" Mechanical Seam, Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. 27499.14 DM Class 1750 1 3/4" Snaplock Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Please see Eval report for Limits of Use. Installation instructions FL27499 R3 IT ISMS516HZ pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 R3 AE DM Eva]12.pdf Created by Independent Third Party: Yes 24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2" standing seams. installation Instructions FL27499 R3 II 15MSS20HZ pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 93 AE DM Eva113 pAf Created by Independent Third Party: Yes 24 Ga. Galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seems, attached to metal deck. Installation Instructions FL27499 R3 II SLSI8BDH2 pdf Verified By: Scott Wolters, P.E. FLPE4 62354 Created by Independent Third Party: Yes Evaluation Reports FL27499 93 AE DM E a1j4 {Ldf Created by Independent Third Party: Yes 27499,15 DM Class 1750 1 3/4" Snaplock .032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams, attached to metal deck. https://www.floridabuilding.org/pripr app_dtl.aspx?param=wGEVXQvdDquHOE2Ywe%2bOsCeDABo3%2hkM8^/2f"/ 2/15/2021 Florida Building Code Online Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II SLAI8BDHZ pdf 1 Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R3 AE DM EvallS.pdf Created by Independent Third Party: Yes 27499.16 DM Class 1750 1 3/4- Snaplock .032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II SLAI8HZ.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes l Design Pressure: N/A Evaluation Reports Other; Please see Eva[ report for Limits of Use. FL27499 R3 AE DM Eva]16 pdf Created by Independent Third Party: Yes 27499.17 DM Class 1750 1 3/4" Snaplock 24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II SLS18H2 pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eva[ report for Limits of Use. FL27499 R3 AE DM Eva117.pdf Created by Independent Third Party: Yes II�27499.18 DM Class 2000 2" Mechanical Seam .032 Aluminum roof panel, 18" wide, with 2" standing seams. IILimits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II 2MSA18HZ pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure; N/A Evaluation Reports Other: Please see Eva] report for Limits of Use. FL27499 R3 AE DM Eva118 pdf Created by Independent Third Party: Yes 27499.19 DM Class 2000 2" Mechanical Seam 24 Ga. galvalume coated steel roof panel, 18" wide, with 2" . Lstanding — seams. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL27499 R3 II 2MSS18HZ.p-df Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R3 AE DM Evall9.pdf Created by Independent Third Party: Yes 27499.20 DM Class 500 5V Crimp 26 Ga. galvalume coated steel roof panel, 24" wide, with Sv crimp. Limits of Use Installation Instructions Approved for use in HVHZ; Yes FL27499 R3 II DM Dwg20.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other; Please see Eva[ report for Limits of Use. FL27499 R3 AE DM Eval2tipdf Created by Independent Third Party: Yes Go to Page 14 m Contact Us :: 2601 Bloir Stone Road, Tallahassee F132399 Phone, 850-487-1824 The State of Florida is an A vEEO employer. g,gl; M 200>-2013 State f FI id :: Privacy statement :: Aaessibiiity Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this endty- Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to section 455.275(I), Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . product Approval Accepts: ® of ht[Y https:llwww.floridabuilding,orglprlpr app_Atf.aspx?param=wGEVXQvADauHOE2Ywe%2bOsCenABnlp/2hkMr-A9PI9fKTPWAI<Cl,.. n.n.ln„.on,.,orz nlc 2/15/2021 Florida Building Code Online Credit Card Sate https://w .floridabUilding.om/pr/pr app dfl.asox?oaraM-wGEVXOwron,]HOF9vwp.049hn�cPnna„ailhlllloI IM 1�11Aievo ............. ..........o.� �,� WOLTERS ENGINEERING ENGINEERING. DRAFTING, CONSULTING 15211 97th Road N West Palm Beach, FL 33412 Ph1Fx:t561) 225-1982 1071 ymm-agn gleam RODUCT: DM CLASS 500 26 GA, GALVALUME 5V CRIMP 24" WIDE ROOF PANEL (FLPA# 27499.20) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD WEST PALM BEACH, FL 33411 To all concerned, The DM Class 500 Series 26 Ga, Galvalume 5V Crimp 24" Wide Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the Th Edition (2020) Florida Building Code. The panel has been tested per TAS 100 and TAS 125 by Intertek with results shown in test reports G3443.38-450-44 and H2686.02- 450-44, and per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports VLS-004- 02-01 and VLS-005-02-01. Technical Documentation: 1. Drawing "5VS-HZ° dated 8/15/19, signed and sealed by Scott Wolters, PE. 2, Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary R Priest, PE. 4, Supplemental Calculations to support °5VS-HZ" drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 24" (nominal) Fastener Spacing across panel: 12" (at Overlaps & Center Rib) Min, Slope: HVHZ: 2712" Non-HVHZ: %112° (with Lap Sealant) 3"112" (no Lap Sealant) C�CIALI?I�i IN Ihtl'�'i I'' :15'!%1N� C,UP'iA,INWrI,i-5, . 0�,::FpON'C5, g vilN�;lWS Field Perimeter & Corner Installation Installation _Max. Design Pressure: 117.75 psf _ _ -206 psf Fastener Spacing: 4" From Ends, 16" Max. O.C. 4" From Ends, 8" Max. O.C. Min Panel Fasteners: #10x1 /2' HiLo HWH Screw _ #10x1 %' HE HWH Screw with Weather -seal Washer with Weather -seal Washer Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note #2 below) Note: Outside of the HVHZ, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami -Dade NOA Note: Outside of the HVHZ, V round plastic caps meeting the requirements of FBC Section 1507.1.1.1 may be used to prevent galvanic reactions. Minimum Substrate: l' (15/32" min) 4-ply CDX Plywood or 3/d' solid wood planks S.G. _ .42 min, nailed to 2x rafters spaced 24" max. on center with 8d ring -shank nails spaced 6" on center. Note: The wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. "�QN..171NG iN IPA 'C1 `15"U" Q1�rAINWA > �;O rpO'7t5 & N.�, SOWS 4. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 5. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL #27499.20, DM Class 500". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 31d party QA provider, to the dimensions shown on Drawing 5VS-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ-4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re -Roofing: The DM Class 500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If ,you have any questions or need more information concerning this approval, please contact me. Thank you, y ®rh- Y�lc S235a Scot� FLPE#62354 ` �, STA7.E ' CCa :;fiw3 %�2� y-�. of •`u�� FCI,N,l/IN6IN hA 171�1 931= - --------- 4p -- --------- ----- ------ � .v.��\\