Loading...
HomeMy WebLinkAboutShwinco Sliding Door Drawings 12519.2 REVISIONS REV DESCRIPTION DATE APPROVED A ADDED NEW CLASS DETAIL 06/15/2021 R.L. NOTES: 15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE REQUIREMENTS OF THE FLORIDA BUILDING CODE. INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING THROUGH FRAME OR STRAP INTO WOOD FRAMING OR 2X BUCK USE #10 TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 1 7. FOR ANCHORING THROUGH FRAME OR STRAP INTO MASONRY/CONCRETE USE 3/1 6" 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1 -1/2" UNITS MUST BE ANCHORED TAPCCNS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/4" MINIMUM EMBEDMENT INTO THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION SUBSTRATE WITH 2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. AND INSTALLATION DETAILS. 5. WHERE WOOD BUCK THICKNESS IS 1 -1/2" OR GREATER, BUCK SHALL BE SECURELY 18. FOR ANCHORING THROUGH FRAME OR STRAP INTO METAL STRUCTURE USE #10 SMS OR FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. DETAILS. 19. ALL FASTENERS TO BE CORROSION RESISTANT. 6. WHERE 1 X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED 20. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND UNIT FRAME INTERIOR FACE SO THAT FULL FRAME SUPPORT SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: IS PROVIDED. A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: GROUT FILLED BLOCK PER ASTM C90 WITH Fm=2,COOPSI MINIMUM. EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/1 6" OR D. METAL STRUCTURE: STEEL 1 8GA (.048") FY=33KS1/FU=52K& OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". ALUMINUM 6063-7`5 FU=30K& .1 25" THICK MINIMUM 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE 21 . APPROVED CONFIGURATIONS: OX, XC, XX, OXX, COX, XOO, OXO, XOX AND XXO. OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1 .6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11 . FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300, SEE SHEET 12 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED: 0613012021 SNWINCO ARCHITECTURAL PRODUCTS, LLC ��� wlilillw// 171 JET SERVICES WAY t�;,\S .R�• ��'dJ�f/� DOTHAN, AL 36303 ��v•y\G�Ns qLp SERIES 9700 VINYL SGD 12080 *■ p $q •�*�_ OXX IMPACT ' - TABLE OF CONTENTS NOTES j w TAT OF �'�� SHEET N0. DESCRIPTION fig•�' DRAWN: DWG NO. REV �� L RlD�; 1 NOTES RALE DATE OS s03592 A a�w� 2 3 ELEVATIONS NTS 07/21/2020 1 OF 12 t II l l 4 11 INSTALLATION DETAILS L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 12 COMPONENTS 434-688-0609 rllomasgIrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED A ADDED NEW CLASS DETAIL 06/15/2021 R.L. 1 47" FRAME WIDTH 1 47" FRAME WIDTH 6" MAX 1 2" MAX O.C. (2) ANCHORS 6" MAX 6" MAX 1 1 " MAX O.C. (1) ANCHOR 6" MAX PER LOCATION PER STRAP 6" MAX 6" MAX 18" 18" MAX MAX O.C. O.C. 96 0 X X 96 X X FRAME FRAME HEIGHT I=> a HEIGHT I > a 6" MAX 6" MAX SERIES 9700 VINYL SGD OXX SERIES 9700 VINYL SGD OXX EXTERIOR VIEW WITH 314"OR 3 314"SILL RISER EXTERIOR VIEW FRAME INSTALLATION DESIGN PRESSURE RATING IMPACT RATING STRAP INSTALLATION +60.OPSF LARGE MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4 NOTES: SIGNED: 0613012021 1. PANEL SIZE:49 3/8"X 93 1/4" 2. PANEL D.L.O.:381/4"x82118" SNWINCO ARCHITECTURAL PRODUCTS, LLC ,,�I��tlldtl�l/�� 171 JET SERVICES WAY t�;,\S .R.• L 0'dl�f/� DOTHAN, AL 36303 � •y�GENs9�,�� SERIES 9700 VINYL SGD 12080 *■ p 81 •�*�_ OXX IMPACT '' - ELEVATIONS 0 w TAT OF � p� DRAWN: DWG NO. REV ��;A.��L/R���.+•�`�� HARDWARE SCHEDULE R.L. 08-03592 A z�/sis�� B. (2)STEEL RO SINGLE ER BYI HS&D AT EACH BOTTOM CORNER OF ACC IVE PANEL LE AT LOCKSTILE,40 1/2"FROM SILL SCALE NTS DATE 07/21�2020 sHEET 2 OF 1 2 II,////1116 \\ C. ALUMINUM REINFORCEMENTAT PANEL TOP, BOTTOMAND JAMBS L.ROBERTO LOMAS P.E. D. ALUMINUM REINFORCEMENT(2"x2"xl/8")AT INTERIOR OF INTERLOCK AND ASTRAGAL 1432 WOODFORD RD LEWISVILLE,NC 27023 Luis R. Lomas P.E. E. ALUMINUM REINFORCEMENT(2"X2"X1/4")AT INTERLOCK EXTERIOR 434-688-0609 rllomasglrlomaspe.com FL No.: 62514 REVISIONS REV DESCRIPTION DATE APPROVED A ADDED NEW CLASS DETAIL 06/15/2021 R.L. 149 1/2" FIN TO FIN 1 1/4" 1 47" FRAME WIDTH 4" MAX 8" MAX O.C. 4" MAX . . . . . . . . . . . . . . . . . . . 4" MAX 1 6" MAX O.C. 96 O X X FRAM E HEIGHT I=> a 4" MAX SERIES 9700 VINYL SGD OXX EXTERIOR VIEW FIN INSTALLATION FOR RATINGS AND NOTES SEE SHEET 2 SIGNED: 0613012021 F.L. O ARCHITECTURAL PRODUCTS, LLC �������tltrrr���� 171 JET SERVICES WAY t�;,\S .R�• ��'dJ�f/� DOTHAN, AL 36303 ��v•y�GENsgs�� SERIES 9700 VINYL SGD 12080 *■ p $q •�*�_ OXX IMPACT ' - ELEVATIONS 0 w TAT Q �'p� DWG N0. REV DATE 08 s03592 A 07/21/2020 3 OF 12 Il II l Iti L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com Igir REVISIONS REV DESCRIPTION DATE APPROVED 1/2" MIN. A ADDED NEW GLASS DETAIL 06/15/2021 R.L. EDGE DISTANCE WOOD FRAMING 1 1/4" MIN. OR 2X BUCK EMBEDMENT 1 1/4" MIN. 1/4" MAX. BY OTHERS EMBEDMENT SHIM SPACE �Q �a 0 BACKER ROD D n & APPROVED 0 o IJ 1/4" MAX. SEALANT � SHIM SPACE 1/2" MIN. ° EDGE DISTANCE ° INTERIOR #10 WOOD SCREW #10 WOOD 0 SCREW Oa ° a WOOD FRAMING OR 2X BUCK o EXTERIOR INTERIOR BY OTHERS BACKER ROD EXTERIOR & APPROVED JAMB INSTALLATION DETAIL SEALANT WOOD FRAMING OR 2X BUCK INSTALLATION 0 � 0 SILL TO BE SET IN A BED OF APPROVED SEALANT #10 WOOD SCREW NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN BACKER ROD FOR CLARITY. & APPROVED 0 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN SEALANT ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH 0 FID 1/4" MAX. FMA/AAMA/WDMA PROTOCOLS WOOD FRAMING ��� °�� SHIM SPACE OR 2X BUCK SIGNED: 06/30/2021 BY OTHERS 1 1/4" MIN EMBEDMENT FSHWINCO ARCNITLCTURAL PRODUCTS, LLC ,, RlitLri����� 171 JET SERVICES WAY `ti; �5 Doi DOTHAN, AL 36303 ��v•y\GENsgs�� 1/2" MIN SERIES 9700 VINYL SGD 12080 *■ p $q ��*�_ EDGE DISTANCE OXX IMPACT FRAME INSTALLATION DETAILS 0 w TAT OF �� VERTICAL CROSS SECTION DRAWN: DWG NO. REV �'�`�•:�L�RID�;.��`�� WOOD FRAMING OR 2X BUCK INSTALLATION R. Al- SCALE 08 s03592 A /�sS'� E[�', N DATE TS 07/21/2020 4 OF 12 /1II1II L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED 1/2" MIN. A ADDED NEW GLASS DETAIL 06/15/2021 R.L. EDGE DISTANCE METAL 1/4" MAX. STRUCTURE SHIM SPACE 1/4" MAX. BY OTHERS SHIM SPACE BACKER ROD D & APPROVED o ado SEALANT o 1/2" MIN. 0 EDGE DISTANCE INTERIOR #10 SMS OR #10 SMS OR �� SELF DRILLING SELF DRILLINGLLI Oa SCREW SCREW a a METAL STRUCTURE EXTERIOR INTERIOR BY OTHERS BACKER ROD EXTERIOR & APPROVED JAMB INSTALLATION DETAIL SEALANT METAL STRUCTURE INSTALLATION 0 � 0 ❑ O ❑ o SILL TO BE SET IN A BED OF APPROVED SEALANT #10 SMS OR NOTES: SELF DRILLING SCREW 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN BACKER ROD FOR CLARITY. & APPROVED 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN SEALANT ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH p p 1/4" MAX. FMA/AAMA/WDMA PROTOCOLS METAL ��� ��� SHIM SPACE STRUCTURE SIGNED: 06/30/2021 BY OTHERS [L. O ARCNITLCTURAL PRODUCTS, LLC ��Nollillw// 171 JET SERVICES WAY t�;,\S .R�• ��'dJ�f/� DOTHAN, AL 36303 Z�v•y�G�Nsgs�� 1/2" MIN SERIES 9700 VINYL SGD 12080 *■ p $q ••*�_ EDGE DISTANCE OXX IMPACT FRAME INSTALLATION DETAILS o , TAT O F c�� VERTICAL CROSS SECTION crr DWG NO. REV METAL STRUCTURE INSTALLATION �� �ORID 0DATE 08 s03592 A /J�si7/00 AL}Ea�07/21/2020 5 OF 12 r II l I L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS 2 3/8 2 MIN. REV DESCRIPTION DATE APPROVED SEPARATION EDGE DISTANCE A ADDED NEW GLASS DETAIL 06/15/2021 R.L. MASONRY/ CONCRETE BY OTHERS Al ° a° d a 1 3/4" MIN. OPTIONAL 1 X BUCK a ° ° EMBEDMENT SEE NOTES 3 — 7 1 3/4" MIN. 1/4" MAX. SHEET 1 + EMBEDMENT SHIM SPACE ° BACKER ROD 0 1/4" MAX. o 2" ° & APPROVED MIN. SEALANT o 0 SHIM SPACE EDGE ° a DISTANCE a ° INTERIOR 2 3/8„ o 3/16" TAPCON SEPARATIONIV L n—va- 3/16" TAPCON 4 °� 'T OPTIONAL 1 X BUCK EXTERIOR INTERIOR SEE NOTES 3 — 7 SHEET 1 ° EXTERIOR MASONRY/CONCRETE JAMB INSTALLATION DETAIL BY OTHERS CONCRETE/MASONRYINSTALLATION Y BACKER ROD & APPROVED SEALANT SILL TO BE SET N A BED OF APPROVED SEALANT 3/16" TAPCON NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN BACKER ROD FOR CLARITY. & APPROVED 0 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN SEALANT ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH FID r� Q 1/4" MAX. FMA/AAMA/WDMA PROTOCOLS OPTIONAL 1 X BUCK SHIM SPACE SEE NOTES 3 — 7 SIGNED: 06/30/2021 SHEET 1 �� SHWINCO ARCHITECTURAL PRODUCTS, LLC MASONRY/ ° 1 3/4' MIN 171 JET SERVICES WAY '.t�; \�? .R.• L til�f/��� Q EMBEDMENT DOTHAN, AL 36303 v■ ti�G�Ns�gs CONCRETE BY OTHERS SERIES 9700 VINYL SGD 12080 *■ p 81 •�*�_ OXX IMPACT 2 3/8" 2" MIN FRAME INSTALLATION DETAILS jq TAT OF ' cr~ SEPARATION EDGE DISTANCE ��, •■ n :4r�� DRAWN: DWG NO. REV sRMot' SR CALE 08 s03592 A �l��S�nNAL}Ea��� VERTICAL CROSS SECTION N DATE TS 07/21/2020 6 OF 12 CONCRETE/MASONRY INSTALLATION L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED 1/2" MIN. A ADDED NEW GLASS DETAIL 06/15/2021 R.L. EDGE DISTANCE 1 1/4" MIN. 1/4" MAX. 1 1/4" MIN. EMBEDMENT SHIM SPACE WOOD FRAMING OR 2X BUCK EMBEDMENT BY OTHERS L�n�QQQQQQoQQQ 1/2" MIN. BACKER ROD D o EDGE DISTANCE & APPROVED SEALANT g 1/4" MAX. a SHIM SPACE #10 WOOD D SCREW UB INTERIOR #10 WOOD SCREW STRAP Q� STRAP a oLL O E � a o a o o� � WOOD FRAMING OR 2X BUCK o EXTERIOR INTERIOR BY OTHERS BACKER ROD EXTERIOR & APPROVED JAMB INSTALLATION DETAIL SEALANT WOOD FRAMING OR 2X BUCK INSTALLATION 0 � 0 0 0 0 0 SILL TO BE SET IN A BED OF APPROVED SEALANT STRAP NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN BACKER ROD #10 WOOD SCREW FOR CLARITY. & APPROVED 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN SEALANT a 1/4" MAX. ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH SHIM SPACE FMA/AAMA/WDMA PROTOCOLS WOOD FRAMING ��a� QQ'�Qa OR 2X BUCK SIGNED: 06/30/2021 BY OTHERS 1 1/4" MIN EMBEDMENT SHWINCO ARCHITECTURAL PRODUCTS, LLC ;��o lilill p// 171 JET DOTHAN, VICES WAY _.t��y`G E �A AL 36303 1/2" MIN SERIES 9700 VINYL SGD 12080 *■ p $q ��*�_ EDGE DISTANCE OXX IMPACT STRAP INSTALLATION DETAILS 0 w TAT OF �� VERTICAL CROSS SECTION DRAWN: DWG NO. RE v �'�`�•:�L0RMot' WOOD FRAMING OR 2X BUCK INSTALLATION R.E DATE 08 s03592 A ��/�sAL NTS 07/21/2020 7 1 7-OF 12 !r II l Iti L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED 1/2" MIN. A ADDED NEW GLASS DETAIL 06/15/2021 R.L. EDGE DISTANCE 1/4" MAX. SHIM SPACE METAL 1/4" MAX. STRUCTURE SHIM SPACE BY OTHERS �nJQQQL�QQ D 1/2" MIN. BACKER ROD D o 10 SMS OR EDGE DISTANCE & APPROVED duo SEALANT Q ° SELF DRILLING #10 SMS OR Q SCREW SELF DRILLING U� INTERIOR SCREW STRAP STRAP Q� °Q a Q � a o a o °� 0 METAL STRUCTURE EXTERIOR INTERIOR BY OTHERS BACKER ROD EXTERIOR & APPROVED JAMB INSTALLATION DETAIL SEALANT METAL STRUCTURE INSTALLATION 0 � 0 SILL TO BE SET IN A BED OF APPROVED SEALANT STRAP NOTES: 1 0 SMS OR 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN BACKER ROD SELF DRILLING FOR CLARITY. & APPROVED SCREW 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN SEALANT ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH D o 1/4" MAX. FMA/AAMA/WDMA PROTOCOLS METAL ��Qp ���� SHIM SPACE STRUCTURE SIGNED: 06/30/2021 BY OTHERS F.L. O ARCHITECTURAL PRODUCTS, LLC ��� wlilillw/�� 171 JET SERVICES WAY tN;,\S .R�• ��'dJ�f/� DOTHAN, AL 36303 Z�v•y�G�Nsgs�� 1/2" MIN SERIES 9700 VINYL SGD 12080 *■ p $q ••*�_ EDGE DISTANCE OXX IMPACT ' - STRAP INSTALLATION DETAILS o , TA OF c�� VERTICAL CROSS SECTION crr DWG NO. REV METAL STRUCTURE INSTALLATION ��RID DATE08s03592 A �07/21/2020 8 OF 12 r II l I L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L N o.: 6 2 51 4 434-688-0609 rllomasglrlomaspe.com REVISIONS 11 2 MIN. REV DESCRIPTION DATE APPROVED EDGE DISTANCE MASONRY/ A ADDED NEW GLASS DETAIL 06/15/2021 R.L. CONCRETE BY OTHERS °° a ° 1 3/4" MIN. 1/4" MAX. OPTIONAL 1 X BUCK EMBEDMENT SHIM SPACE 1 3/4" MIN. ° °° � � EMBEDMENT SEE NOTES 3 — 7 ° SHEET 1 QQ 2 MIN.QQ�QQaQQQp "QQ BACKER ROD D o EDGE DISTANCE 1/4" MAX. & APPROVED ° ado SHIM SPACE SEALANT ° ° 3/16" TAPCON a 3/16" TAPCON o OB INTERIOR STRAP o STRAP ° l OPTIONAL 1 X BUCK LL] LLLJ 0( SEE NOTES 3 — 7 SHEET 1 ° v 0 MASONRY/ CONCRETE o EXTERIOR INTERIOR BY OTHERS EXTERIOR BACKER ROD JAMB INSTALLATION DETAIL 1 1[ & APPROVED CONCRETE/MASONRY INSTALLATION 0 SEALANT SILL TO BE SET IN A BED OF APPROVED SEALANT STRAP NOTES: LJ 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN BACKER ROD 3/16" TAPCON FOR CLARITY. & APPROVED 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN SEALANT ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH D o a 1/4" MAX. FMA/AAMA/WDMA PROTOCOLS OPTIONAL 1 X BUCK ��Qp ���� SHIM SPACE SEE NOTES 3 — 7 SIGNED: 06/30/2021 SHEET 1 SHWINCO ARCHITECTURAL PRODUCTS, LLC �o wlilillw/�� MASONRY/ a ° ° ° 1 3/4" MIN 171 JET SERVICES WAY .t�; \�? .R�• �0til�f/�� CONCRETE EMBEDMENT DOTHAN, AL 36303 BY OTHERS ° • SERIES 9700 VINYL SGD 12080 -*a y0 OXX IMPACT ' - 2" MIN INSTALLATION DETAILS 0 w TAT OF •'�� EDGE DISTANCE �0.6 . 4r� DRAWN: DWG N0. REVzi �� ;�L�R�D�;• \��� VERTICAL CROSS SECTION R.L. 08-03592 A /ii/' S'/0 VAL CONCRETE/MASONRY INSTALLATION SCALE NTS DATE 07/21/2020 SHEET 9 OF 12 �/1/11II110�� L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS APPROVED REV DESCRIPTION DATE APPROVED SEALANT 1 1/4" MIN. A ADDED NEW GLASS DETAIL 06/15/2021 R.L. BEHIND FIN EMBEDMENT WOOD #8 WOOD FRAMING SCREW BY OTHERS 7/16" MIN pQ�� Q 1/4" MAX EDGE DISTANCE D Qp n° n SHIM SPACE 1/4" MAX SHIM SPACE 0 WOOD FRAMING BY OTHERS #8 WOOD SCREW INTERIOR a� 1 1/4" o Oa ° O O MIN. Sul Sul EMBEDMENT1 D� a d INTERIOR APPROVED EXTERIOR SEALANT EXTERIOR BEHIND F I N 7/16" MIN EDGE DISTANCE o o JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 0 0 0 0 NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN 0 ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH n p o FMA/AAMA/WDMA PROTOCOLS o `UIM 1/4" MAX SIGNED: 0613012021 SHIM SPACE SHWINCO ARCHITECTURAL PRODUCTS, LLC �o wlilillw// 7/16" MIN 171 JET SERVICES WAY .tti;�\�? .R-• ��ti19/�� DOTHAN, AL 36303 v•+ �G�fY�+ .•S EDGE DISTANCE WOOD ti FRAMING SERIES 9700 VINYL SGD 12080 *• 0V$q#8 WOOD WOOD SCREW 1 1/4" MIN. BY OTHERS OXX IMPACT ��• i cr; FIN INSTALLATION DETAILS TATeO'FAPPROVED EMBEDMENT 0; SEALANT DRAWN: DWG NO. REV BEHIND FIN VERTICAL CROSS SECTION R.L. 08-03592 A WOOD FRAMING OR 2X BUCK INSTALLATION SCALE NTS DATE 07/21/2020 SHEET 10 OF 12 L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS APPROVED REV DESCRIPTION DATE APPROVED SEALANT BEHIND FIN A ADDED NEW GLASS DETAIL 06/15/2021 R.L. METAL STRUCTURE #8 SMS OR BY OTHERS SELF DRILLING SCREW EDGE DISTANCE MIINCE l� nJ 0 Qp� Q SHIM SPACE 1/4" MAX Q METAL STRUCTURE SHIM SPACE o BY OTHERS ago a 0 8 SMS OR INTERIOR SELF DRILLING SCREW INTERIOR rc EXTERIOR APPROVED EXTERIOR SEALANT BEHIND FIN 7/16" MIN EDGE DISTANCE o o JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION ❑ O ❑ O NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH FBC RESIDENTIAL AND BUILDING AND WITH FMA/AAMA/WDMA PROTOCOLS `UI U 1/4" MAX s H I M SPACE SIGNED: 06/30/2021 FR.L. O ARCNITLCTURAL PRODUCTS, LLC ��� wlilillw/�� 7/16" MIN 171 JET SERVICES WAY tNS .R�• ��'dl�f/� EDGE DISTANCE DOTHAN, AL 36303 ��v+'�GEIY�+'•9cA�� #8 SMS OR BYTAL OTHERS STRUCTURE � 4- �?;gf SERIES 9700 VINYL SGD 12080SELF DRILLING OXX IMPACTSCREW FIN INSTALLATION DETAILS OF •'�� 4r APPROVED DWG NO. REV i��~ R`D�• SEALANT VERTICAL CROSS SECTION 08-03592 A BEHIND FIN METAL STRUCTURE INSTALLATION DATE sHEET ��� nMAL 07/21/2020 11 OF 12 L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS aae e�� a INTERIOR REV DESCRIPTION DATE APPROVED 00 oo �a �� oo A ADDED NEW GLASS DETAIL 06/1 5/2021 R.L. �000 0 o p00000�anod pao oa �o 0o ao oa �o 0o q �a 1 3/4" 4 1/16,> o0 0o ao 00 �p moo EXTERIOR a� 5 1 6 14 T rr�=- HORIZONTAL CROSS SECTION tFIN FRAME 3/1 6" STRAP FOR REFERENCE ONLY, SEE SHEETS 4-11 FOR INSTALLATION DETAILS PVC.070"THICK GALVANIZED STEEL.065"THICK 5 7/8" 3/4„ 2„ 2 5/8" 1/2" 3/8" 2" COVER +1 7/8 PVC.060"THICK 1 � � REINFORCEMENT (`—J�-1��a71 IL���o7��a� 1 3/4" � ALUMINUM 1/8"THICK GLAZING BEAD C� REINFORCEMENT 2 15/16" PVC.050"THICK FINLESS FRAME ALUMINUM 1/8"THICK PVC.070"THICK 5 7/8" 1 9/16 2 1/4" ° 11/16" 1 7/8" 5 7/1 6" 0 � 4 3/4 o O 3 9/16" 3 5/16" 2 11/16" FIN FRAME a D PVC.070"THICK SASH FRAME SASH REINFORCEMENT INTERLOCK ASTRAGAL SILL RISER PVC.070"THICK ALUMINUM.090"THICK PVC.060"THICK PVC.070"THICK ALUMINUM.070"THICK 1 15/16" 1 " 1 " 3/1 6" H.S. 13/16" EXTERIOR 3/16" HS EXTERIOR 0.075" VANCEVA SIGNED: 0613012021 qii4 0.075" PVB BY EASTMAN � BY EASTMAN SHWINCC ARCHITECTURAL PRODUCTS, LLC ����titrrr�/ TRACK 1/4" TEMP 3/16" HS 3/16" TEMP 3/16" H.S. 171 JET SERVICES WAY ����\5 R.. L�4J7�f/ ALUMINUM.060"THICK �� � + ` • ` .DOTHAN -9 , AL 36303 DURASEAL DURASEAL v,•ti�G N�+�; BY QUANEX BY TRUSEAL 1 15/16" SERIES 9700 VINYL SGD 12080 INTERIOR INTERIOR OXX IMPACT Tad 0 , crz 7/8" BITE 0 7/8" BITE COMPONENTS . �� DOW 995 DRAWN: DWG NO. REV ��� •r�ZORl��;. 1 1/4" ❑ DOW 995 ❑ s��`S► �y SETTING BLOCK SETTING BLOCK RA E DATE 08 s03592 A / n E 598000CA BY PTI 598000CA BY PTI NTS 07/21/2020 12 OF 12 Il II l Itil RISER GLAZING DETAIL A EPDM 80 DURO GLAZING DETAIL B EPDM 80 DURO L.ROBERTOLOMASP.E. ALUMINUM.060"THICK 1432 WOODFORD RD LEWISVILLE,NC 27023 Luis R. Lomas P.E. 434-688-0609 rllomasga lrlomaspe.com FL No.: 62514