Loading...
HomeMy WebLinkAboutRevisions L 11OF190 pastnay 601 716 :DDD7S 1 8886-98L-ZLL :(aWIZAV10n1 Q)9IOHd t86t£ dIZ 31S lZiOd LIO 16 3210W119 MS t866 :SSHUC[C V 2:f HO-13M lnvd :AVVVN �I�iOIZVIAi2IO,dI�II 2I��I�IOl�i�/.L��.LIH02I�' :XV3 0900-9££-ZLL :aINILAV(I)HNOHd t86t£ :dIZ -u ULV.LS 31On-1 1S- iOd :A LID co 311nS OAl9 lsd Ms WZ:SSUIQQd OlW1NOIN)I2JVIN �iVN :molLvwuodml WI(IrlIIISRIUmmo r!7��T 7r �7 I XV3 0900-9££-ZLL :(al�LIJAV(I) 9NOHd test£ :dIZ id :R.LV.LS 31On-i is i�:jOd :A.LIO £06 311nS Onl9 lsd Ms WZ :SSa2IQ(lV 01-iViNOIN)1adw :HWVN SUF[IJIZVfIO 'ONI'S3I12:i3d021d 310ni is 12iOd :MIVN SS9ISfIS 0za£ :# 'L2I�� 00 aIDfl'I •.LS zLo£9at.090 # 'I2I��/1J�2I I330�ZV LS WOILVWHOINI2IOZ3vdjL oD JNIMVZ:IO 510nO'3(100 AE)IJDN3'f-lHnNVN ON O3SIAAH SNOISIAa-H .LDaf02id do AIOILdraDsaa QA'IIV.Lau Z86t£ld'302�31d 12�Od P^I9lasunS Z169 :SSa2IQQV aZIS/mol LVD01 NOI1dWUOJN1103f021d SNOISIAM IIW213d Minna MOd NOI.LV011dd`d £556-Z9b(Z11) Z999-Z86ti£l3`30N31d 12103 3nN3AV dINIONIA 00£Z NIOISIAI I NOI.LV'IfI9ad AQOO'8 ONIIQ'IIflg SADIA2HAS ,LA UUJOrlaAaQ IY 9NINNVrld i i # :aHA NOISIAAH 6££o-6OLZ :Qa'IId al u I :ArINO asfl axiAo i- I Load Short Form Job: Air Calcs LLC Date: Aug Aug 06,Zozo House By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:\,ic4dlyrm@aircalcs.com i Project • • For: Shockley Residence,Air Conditioning Unlimited 5912 Sunset Blvd,Fort Pierce,FL 34982 Design Information Htg Cig Infiltration Outside db(°F) 41 90 Method Simplified 5 Construction quality Average Inside db( F) 70 7 q ty 9 Design TD(°F) 29 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(grAb) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S301A AHRI ref Coil ASPT39C14A AHRI ref 201785799 Efficiency 100 EFF Efficiency 13.0 EER,15.5 SEER Heating input 5.6 kW Sensible cooling 19600 Btuh Heating output 19097 Btuh Latent cooling 8400 Btuh Temperature rise 19 °F Total cooling 28000 Btuh Actual airflow 933 cfm Actual airflow 933 cfm Airflowfactor 0.049 cfm/Btuh Airflowfactor 0.051 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.78 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) i WIC 29 900 275 44 14 M Bath 44 1390 523 68 27 Master Bedroom 179 2677 2213 131 113 Foyer 42 0 0 0 0 Pantry 14 0 0 0 0 Great Room 258 3999 4725 196 242 Bath 47 587 284 29 15 Lin 6 0 0 0 0 Bed 3 167 2896 2083 142 107 Bed 2 151 2935 2117 144 108 Hall 40 0 0 0 0 DR/Kt 256 3703 6034 181 309 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2021-Nov-0513:19:21 WI'IghtsOft®I—Z7- Right-Sute®Uriversa1202121.0.08RSU27054 Page 1 ACCK ...s\WrightsoftHVAC15912SLrwt Blvd PSLPropnp Calc=MJ8 Front Door faces:N i House d 1232 19088 18254 933 933 Other equip loads 1349 716 Equip.@ 0.95 RSM 18098 Latent cooling 5434 TOTALS 1232 20437 23532 933 933 i i I Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft® 2021-Nov-05 13:1921 Right-Sute®Uriversal 2021 21.0.08 RSU27054 Page 2 MrigHsoft HVAC\5912 Suset Blvd PSL Propnp Calc=MJB Frord Door faces:N i • Building Analysis Job: Aug 1300 Air Calcs, LLC g Y Date: Aug 06,2020 House By. Vicki Lynne Nisa Air Calcs, LLC 7I 50 Hidden Hammod<LR Vero Beach,FL32966 Phone:772.800.8413 Email:,Acldlyrm@aircalcs.com I Project • • For. Shockley Residence,Air Conditioning Unlimited 5912 Sunset Blvd,Fort Pierce,FL 34982 I Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 2A 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh %of load Walls 3.1 3944 19.3 ventilation Glazing 17.9 2331 11.4 Wall Doors 3.7 77 0.4 ucts Ceilings 1.0 1221 6.0 Floors 3.8 4732 23.2 Infiltration 2.3 2588 12.7 Glazin Ducts 4193 20.5 Piping 0 0 other Humidification 0 0 Ceilings Infiltration Ventilation 1349 6.6 Adjustments 0 Total 20437 100.0 Floors Component Btuh/ftz Btuh %of load Walls 1.8 2299 12.1 Walls Ventilation Glazing 28.2 3676 19.4 Doors 3.7 78 0.4 nternal Gains Ceilings 1.8 2224 11.7 Floors 0 0 0 Glazin Infiltration 0.6 702 3.7 Ducts 4754 25.1 Ventilation 716 3.8 y Internal gains 4520 23.8 other Blower 0 0 Ceilings Adjustments 0 Ducts Total 1 1 18970 100.0 Infiltration Latent Cooling Load=5434 Btuh Overall U-value=0.109 Btuh/ft�-°F Data entries checked. wrightsoft- 2021-Nov-0513:19:21 Riga-Sute@ Universal 2021 21.0.08 RSU27054 Page 1 ACCK ..s\WrightsoftHVAC15912S<nsetBlvdPSLProp.np Calc=MJ8 FrontDoorfaces:N Component Constructions Job: Aug1300 'Air Calks, LLC p Date: Aug 06,zozo House By. Vicki Lynne Nisa Air Calcs, LLC 7I 50 Hidden Hammock Ln,Vero Beach,FL32966 Phona:772.800.8413 Email:vicWlyrre@aircalcs.com I Project Information For: Shockley Residence,Air Conditioning Unlimited 5912 Sunset Blvd,Fort Pierce,FL 34982 I Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD(°F) 29 15 Latitude: 280N Relative humidity(%,) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 g gs Or Area U-value Inul R Ht HTM Loss CI HTM Gain Construction descriptions • ft' BtuWft'°F ft'-F/Btuh Btutdft' Btuh BtuWft' Btuh iWalls Blk Wall,Stucco Ext,R-4.1 Ext Bd Ins,8"Thk, 1/2"Gyp Bd Int Fnsh n 105 0.109 5.1 3.15 330 2.02 211 e 410 0.109 5.1 3.15 1292 2.02 826 s 217 0.109 5.1 3.15 685 2.02 438 w 253 0.109 5.1 3.15 796 2.02 509 all 985 0.109 5.1 3.15 3102 2.02 1984 Frm Wall Ext Knee Wall,Stucco Ext,R,30 Cav Ins,1/2"Gyp Bd Int Fnsh, w 9 0.055 30.0 1.61 14 0.76 7 2N6"Wd Frm,16"OC Stud Partitions Frm Wall,1/2"Gyp.Bd Ext,R-11 Cav Ins, 1/2"Gyp Bd Int Fnsh,2N4",16" 282 0.101 11.0 2.94 827 1.09 308 OC Stud Windows Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); n 4 0.580 0 16.8 67 11.4 45 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(2 ft window ht,1 ft sep.);6.89 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); e 9 0.580 0 16.8 151 27.6 248 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(3 ft window ht,1 ft sep.);6.89 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); e 31 0.580 0 16.8 525 27.6 860 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(5.2 ft Wndow ht,1 ft sep.);6.89 ft head ht Impact,Clear Lowe,TEMP:Impact,Clear Lowe,TEMP;NFRC rated a 40 0.650 0 18.9 746 32.2 1275 (SHGC=0.21);foreground=green grass(0.23);1 ft overhang(6.6 ft window ht, 1 ft sep.);6.89 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.22); w 16 0.620 0 18.0 280 26.7 416 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(5.2 ft window ht,1 ft sep.);6.89 ft head ht w 31 0.620 0 18.0 561 26.7 832 all 47 0.620 0 18.0 841 26.7 1248 wrightsoft` 2021-Nov-0513:19:21 Right-Stite@)Uriversal 202l 21.O.O8 RSU27054 Page 1 s1W dgNsoft HVAC\5912 Strti et Blvd PSL Propnp Calc=MJ8 Front Door faces:N I I Doors Fbrgls Door w 21 0.127 7.0 3.69 77 3.73 78 Ceilings Attic,Shngl Roof,R•30 Ceil Ins,1/2"Gyp Bd Int Fnsh 1232 0.034 30.0 0.99 1221 1.80 2224 Floors On Grade Depth,Tile Flr Fnsh 165 0.989 0 28.7 4732 0 0 -114k wrightsoft® 2021-Nov-0513:19:21 <r.k•a�,,rA. Right-Sate®Uriversal 2021 21.0.08 RSU27054 Page 2 MrigffsoftHVAM912Suset Blvd PSLProp.nQ Calc=MJB Fror6 Door faces:N Project Summary Job: 4ir Calcs, LLC 1 ry Aug Date: Aug 06,zozo House By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock LR Vero Beach,FL32966 Phone:772.800.8413 Email:vicldlyrm@aircalcs.com Project • • For: Shockley Residence,Air Conditioningg Unlimited 5912 Sunset Blvd,Fort Pierce,FL 34J82 Notes: Design Information Weather: St Lucie Co Intl,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 29 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 57 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14895 Btuh Structure 13500 Btuh Ducts 4193 Btuh Ducts 4754 Btuh Central vent(42 cfm) 1349 Btuh Central vent(42 cfm) 716 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20437 Btuh Use manufacturer's data n Rate/swin multipplier 0.95 Infiltration Equipmen sensiN load 18098 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2404 Btuh Ducts 1395 Btuh Central vent(42 cfm) 1635 Btuh Heating Cooling Outside air Area(ft2) 1232 1232 Equipment latent load 5434 Btuh Uolume(ft3) 10828 10828 Airchanges/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 23532 Btuh Equiv AVF(cfm) 81 42 Req.total capacity at 0.70 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S301A AHRI ref Coil ASPT39C14A AHRI ref 201785799 Efficiency 100 EFF Efficiency 13.0 EER,15.5 SEER Heating input 5.6 kW Sensible cooling 19600 Btuh Heating output 19097 Btuh Latentcooling 8400 Btuh Temperature rise 19 °F Total cooling 28000 Btuh Actual airflow 933 cfm Actual airflow 933 cfm Airflowfactor 0.049 cfm/Btuh Airflowfactor 0.051 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -F- wri_ghtsoTt® 2021-Nov-0513:19:21 •�T•^ °� RighFSute®Unversal 2021 21.0.08 RSU27054 Page 1 sUrighrsoft HVAQ5912 Sunset Blvd PSL PropnQ Calc=MJ8 Front Door faces:N 9 I I 00 Air Calcs, LLC Right-M Worksheet Job: Aug hIOUSe Date: A Aug 06,2020 By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vicidlyme@aircaks.com i 1 Room name House WIC 2 E)posed wall 165.0 ft 10.8 ft 3 Room height 8.8 ft d 82 ft heat/cool 4 Room dimensions 5.5 x 5.3 ft 5 Room area 1232.3 ft 28.9 ft Ty Construction U-value Or HTM Area (f 2) Load Area (f 2) Load number (Btuh/t22F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 V1/ . Blk Wall,Stucco FAQ 0.109 n 3.15 2.02 109 105 330 211 -43 43 136 -7 -G Impact Clear LowQ Ob80 n _16.82 :-11.37 4 0 _. _ 67 45 _0 0 0 . _ 0 Blk Wall,Stucco 6d 0.109 a 3.15 2.02 490 410 1292 826 0 0 0 0 impact,Clear Lowe 0.580 a 16.82 27.57 9 0 151 248 0 0 0 0 11 Impact,Clear Lowe 0.580 a 16.82 27.57 31 0 525 860 0 0 0 0 Impact Clearl-ow-e,. 0.650 _e 18.85 32.19 , 40 0 746 1275 0 0 0 0. W- Blk Wall,Stucco Ext 0.109 s 3.15 ._ 2.02 217 217 685 _- 438 _ 0 0 0 Blk Wall,Stu000 Ext 0.109 w 3.15 2.02 320 253 796 509 0 0 0 0 Impact,Clear Lowe 0.620 w 17.98 26.67 16 0 280 416 0 0 0 0 Impact,Clear Lowe 0.620 w 17.98 26.67 31 0 561 832 0 0 0 0 Fbrols Door _. 0.127 w 3.69 _ 3.73 21 _ 21 _77 78 0 0 0. _ 0 w Ffm Wall Ext Knee Wa 0.055 iv 1.61 0.76 9 9 -. 14 7 0 0 6 0 P Frm Wall,12-Gyp,B 0.101 - 1.09 282 . 282 _827 _ 308 45 45 132 _49 C_ _ At6g Shngl Roof,R. 0.o34 0.99 ,- 1.80 1232 1232 .1221 _2224 29 _ _ 29 _ _ 29 52 F On Grade Depth,Tile 0.989 28.68 0.00 1232 165 4732 0 29 11 308 0 6 c)AED excursion 0 -11 Envelope loss/gain 12307 8278 605 177 12 a) Infiltration 2588 702 97 26 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 4 920 0 0 Applianceslother 3600 0 Subtotal(lines 6 to 13) 14895 13500 702 203 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 14895 13500 702 203 1151 Duct loads 128% 35% 4193 4754 28% 35%1 198 72 Total room load 19088 18254 900 275 Air required(dm) 933 933 44 14 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -�- wrigF�tsoR� 2021-Nov-0513:19:21 Right-Sute®Universal 2021 21.0.08 RSU27054 Page 1 MrightsoftHVAC15912 Sunset Blvd PSL Prop rup Calc=MJ8 FrontDoorfaces:N Air Calcs, LLC Right-M Worksheet Job: 1300 HouseDate: Aug 06,2020 By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vicldlynne@aircalcs.com 1 Room name M Bath Master Bedroom 2 Exposed wall 13.5 ft 27.0 ft 3 Room height 82 ft heat/cool 82 ft heaY000l 4 Room dimensions 5.5 x 8.0 ft 13.5 x 13.3 ft 5 Room area 44.0 ft 178.9 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ft=) Load number (Btuhrft'°F) (Btuhift-) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 VtJ Blk Wall,Stu' End 0.10-9 66 n 3.15 . 2.02 62 :194 124 6 6 0 _L-_ 0 _G ImpadClearLow-e 0.580 n 16.82 11.37 4 - _ 0 67 45 0 0 _ 0 0 Blk Wall,Stucco Ext 0.109 a 3.15 2.02 45 45 142 91 111 95 300 192 Impact,Clear Lowe 0.580 e 16.82 27.57 0 0 0 0 0 0 0 0 11 Impact,Clear Lowe 0.580 a 16.82 27.57 0 0 0 0 16 0 262 430 �i Imnact.Clear Lowe, 0.650 _ e 18.85- .32.19 0 0 0 0 0 0 0 0 W- BIk Wan,Stucco Ext- _ .o.109 -s _3.15. 2.02 0 - _0 0 _ 0 ... 0 0--- - . . 0 .. 0 Blk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 FbrglsDoor - 0.127 ._w 3.69 . .. 3.73 _ ._ 0 0 0 0 0 0 ...,- 0 .. 0 W- _ Frm Wall Ei KneeWa _ 0.055 _w._ 1.61 0.76 0 0, 0 0 0 0 _ 0 0 P Frm Wall,1C2"Gyp.B 0.101 2.94 1.09 0 _0 . _ 0 0 111 111, ,-._ 325 121 C. Attic Shngl Rogf,R- _ __ 0.034__ -_ 0.99 1,80 44 ._ 44 _ ,. 44_ 79 179 179 _ 177 323 F , .On Grade_Depth,Tile 0989 28.68 0.00 44 14 387 0 179 27 - 774 0 6 c)AED excursion -21 3 Envelope losstgain 834 319 1839 1068 12 a) Infiltration 250 68 250 68 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 500 Subtotal lines 6 to 13 1084 387 20( ) 89 1636 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1084 387 2089 1636 1151 Dud loads 1 28% 35% 305 136 28% 35%1 588 576 Total room load 1390 523 2677 2213 Air required(dm) 68 27 1311 113 I Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �It wrigF�tsofi� 2021-Nov-0513:19:21 RiACACNght-S ited)Urrversa12021 21.0.08 RSU27054 Page 2 MrigttsoftWACl5912Suset Blvd PSLPropnp Cale=W8 Front Door faces:N I Air Calcs, LLC Ri ht-M Worksheet Job: 1300 House By. Aug 06,2020 By. Vicki Lynne Nisa Air Calcs, LLC I 7550 Hidden Hammock Lq Vero Beach,FL 32966 Phone:772.800.8413 Email:vicidlyrme@aircalcs.com i 1 Room name Foyer Pantry 2 Exposed well 13.0 It 0 It 3 Room height 9.5 ft heaV000l 82 ft heaUmol 4 Room dimensions 6.0 x 7.0 ft 4.0 x 3.5 It 5 Room area 42.0 ft' 14.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ftz) Load number (B1uhAt'-'F) (BtuhAt') or perimeter (ft) (Btuh) or perimeter (ft) (BTuh) Heat I Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 Vr Blk V Iall,Stu000 F)d 0.109 n 3.15 2.62 0 6 6 0 0 0 0 6 - C Impac,Clear Lowme 0.580 n 16.82 11.37 _ 0 _, 0 _ 0 0 0 --0 0' 0 0 Blk Wall,Stucco Ed 0.109 a 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 a 16.82 27.57 0 0 0 0 0 0 0 0 11 Impad,Clear Low-e 0.580 a 16.82 27.57 0 0 0 0 0 0 0 0 vl� Impact,Clear Lowe, 0.650 a 18.85- 32.19 -_ 0 0 0 0 0 -0 0 0 W- Blk Wall,Stucco Ext 0.109 .s 3.15- 2.02 0 0 -. -_ 0 - 0 0 0 - . . 0 - 0 Blk Wall,Stucco E)d 0.109 w 3.15 2.02 48 27 85 54 0 0 b 0 Impact,Clear Lowe 0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 _.._ Fbrols Door....._ . , . _0.127 _w 3.69. 3.73 21 -. 21 .. _ .. .77_ 78 0 0 -0 0 W Frm Wall F)d Knee Wa 0.055 w 1.61 -0.76 .- 9 9 - 14 7 0 0 0 0 P Frm Wall,Ia-Gyp.B 0.101 2.94 1.09 67 67 _ 195 73 0 0 _ 0 _ _-0 C Attic,Shin Roof,R 0.034 _ 0.99 1.80 42 - 42 42 _76 14 _ 14 .- 14 _ - 25 F On Grade Depth,Tile 0.989 28.68 0.00 42 13 373 0 - 14 0 0 0 6 c)AED excursion -17 -1 Envelope loss/gain 787 271 14 24 12 a) Infiltration 129 35 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal(lines 6 to 13) 916 306 14 24 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistri bution -916 -306 -14 -24 14 Subtotal 0 0 0 0 15 Ductloads 28% 35% 0 0 28% 35% 0 0 Total room load 0 0 0 0 Air required(dm) 0 0 1 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -PFF- wr7ghtsotF!- Right-Sute®Universal 2021 21.0.08 RSU27054 2021-Nov-0513:19:21Page 3 s\WdgtgsoftHVAC\5912Suzet Blvd PSLProp.np Cale=MA Front Door faces:N i !Air Calcs, LLC Right-J®Worksheet Job: 1300 House By. Aug 06,2020 By. Vicki Lynne Nisa Air Calcs, LLC i 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:viddlyrre@aircalcs.com 1 Room name Great Room Bath 2 Exposed mall 20.3 ft 5.5 ft 3 Room height 9.5 ft heaNcool 82 ft heaUcool 4 Room dimensions 1.0 x 258.0 ft 5.5 x 8.5 ft 5 Room area 258.0 T 46.8 ft Ty Construction U-value Or HTM Area OF) Load Area (ft 2) Load number (BtuhAt'°F) (BtuhAt') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vf/ Blk Wall,Stucco Ext 1-11 0.109 n 3.15 IM 6 0 0 0 0 0 0 0 L-C lmpad ClearLow*e- 0.580 n 16.82 11,37 0 0 - 0 0 0 0 0 0 Blk Wall,Stucco Ext 0.109 a 3.15 2.02 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 a 16.82 27.57 0 0 0 0 0 0 0 0 11 Impact,ClearLow-e 0.580 a 16.82 27.57 0 0 0 0 0 0 0 0 Impact ClearLow-e, _0.650 .e 18.85 32.19 0 0 0 0 0 0 0 0 W Blk Wall,Stu000 Ext, 0.109 s 3.15 2.02 0 -0 - 0 0 0 0 _ _ 0 _0 �j Blk Wall,Stucco Ext 6.109 w 3.15 2.02 133 102 321 205 45 45 142 91 I-C Impact,Clear Lowe 0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 !�pG Impact Clear Lowe 0.620 w 17.98 26.67 31 0 561 832 0 0 0 0 FbrglsDoor 0.127. w 3.69 3.73 0 . 0 - .0 0 0 0 0 0 W -- Frm Wall Ext Knee Wa_ 0.055 w 1..61 .._0.76 -. 0 -0_ 0 0 .0 0 0 0 P Frm Wa11,1I2"Gyp.B 0.101 2.94 1.09 59 59 _174 65 0 0 0 0 C Attic,5hngl Roof R 0,034 0.99. 1.80 _ 258 258 -_ 256 466 47 47 _ 46 .8_4 F On Grade Deptli,Tile 0.989 28.68 - 0.00 _ 258 20 581 _0 47 6 _ 158 0 i 6 c)AED excursion 159 -11 Envelope loss/gain 1893 1726 346 165 12 a) Infiltration 301 82 102 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 900 0 Subtotal(lines 6 to 13) 2193 3168 448 192 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 927 327 10 17 14 Subtotal 3121 3495 458 210 15 Duct loads 1 28% 35% 879 1231 28% 35%1 129 74 Total room load 3999 4725 587 284 Air required(dm) 1 1 196 242 29 15 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsoR' 2021-Nov-0513:19:21 ACCA R ght-Sute®U rversa12021 21.0.08 RSU27054 Page 4 slWdgltsoftHVAC15912 Sunset Blvd PSLPropnQ Calc=MJ8 Front Door faces:N i I !Air Calcs, LLC Right-J®W.orksheet Job: 1300 House Date: Aug 06,2020 j By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vicdlyrre@aircalcs.com 1 Room name Lin Bed 3 2 Exposed well 0 ft 25.5 It 3 Room height 8.2 It heaUceol 82 ft heat/oocl 4 Room dimensions 2.0 x 3.0 ft 1.0 x 167J It 5 Room area 6.0 ft2 167.1 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (T) Load number (Btuh/t'-F) (BtuhAt') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 T Blk Wall,Stucco E)d 0.169 n 3.15 2.02 0 0 _ 0 _o 0 0 0 0 �--G Impact,Clear Lowe 0.580 _n 16.82 _ 11.37 0 - 0 0 0 0 0 0 0 Blk Wall,Stucco Ext 0.109 a 3.15 2.02 0 0 0 0 111 95 300 192 Impact,Clear Low-e 0.580 a 16.82 27.57 0 0 0 0 0 0 0 0 11 Impact,Clear Low-e 0.580 a 16.82 27.57 0 0 0 0 16 0 262 430 vh Impact,Clear Lowe, . 0.650 ._e_ 18.85. 32.19 - 0..- 0 0 _ 0 , . 0 0 .. 0 0 ',W ` Blk Wall,Slpoc Exf _ 0.109 s 3.15 2.02 0 - _ 0 _ 0 _ 0 ._, 98 98 , 310 198, L�bBlk Wall,Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Low-e0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 Impact,Clear Low-e0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 FbrglsDoor, 0.127 w -. 3.69 _ 3.73 0 0 0 - 0 W Frm Wall ExtKnee Wa 0.055 w 1.61. _ _ 0.76 ..0 -0 0 0 .,, 0 0 0 .0 P Frm Wall,10"Gyp.B- 0.101 - 2.94 1.09 0 0 0 0 0 0 0 0 - - - - ... . C„ Attic Shngl Roof,R; 0.034 -_. 0.99 _ 1.80 6 6 6 _ _ _ 11 167 _ 167 ,-. 166 302 F On Grade_Depth,Tile 0.989 - 28.68 0.00 6 0 0 0 167 06 _ 731 6 6 c)AED excursion -1 10 Envelope loss/gain 6 10 1769 1131 12 a) Infiltration 0 0 473 128 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianceslother 0 250 Subtotal(lines 6 to 13) 6 10 12242 1510 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -6 -10 18 31 j 14 Subtotal 0 0 2260 1541 15 Ductloads 128% 35% 0 0 28% 35% 636 543 Total room load 0 0 2896 2083 Air required(cfm) 0 0 142 107 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -!'}F wrigtitsoft� 2021-Nov-0513:19:21 Right-Suite®Universal 2021 21.0.08 RSU27054 Page 5 sUrightsoft HVAC15912 Suset Blvd PSL Prop nup Calc=MJ8 Front Door faces:N i Air Calcs, LLC Right-J®Worksheet Job: 1300 i House Date: Aug 06,2020 By. Vicki Lynne Nisa Air CaIGs, LLC i 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:viddlyme@aircalcs.00m 1 Room name Bed 2 Hall 2 E)posed%wil 26.0 ft 0 It 3 Room height 8.2 It heat/cool 82 ft heaUcool 4 Room dimensions 1.0 x 150.9 It 1.0 x 39.5 ft 5 Room area 150.9 ft' 39.5 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (BtuhAt''F) (BtuhAt') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 1V Blk Wall,Stucco D� 6.109 n 3.15 2.02 0 0 0 0 0 0 0 0 _ _Impact Clear Lower- 0.580 __n_ 16.82 11.37 -0 0 0 0. _0 0 0 0 Blk Wall,Stucco Ext 0.109 a 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Low-e 0.580 a 16.82 27.57 0 0 0 0 0 0 0 0 11 Impact,Clear Lowe 0.580 a 16.82 27.57 0 0 0 0 0 0 0 0 Impact Clear Low e.-, 0.650 e _18.85_ 32.19 0 0 _ 0 0, 0 0 0, 0 W Blk.Wall,Stucco FA _ 0.109 s 3.15 _ 2.02 119 119. 375 - 246 0 0 0 _0 VUBlk Wall,Stucco Ext 6.169 w 3.15 2.02 94 79 248 159 6 0 0 0 Impact,Clear Lowe 0.620 w 17.98 26.67 16 0 280 416 0 0 0 0 Impact,Clear Low-e 0.620 w 17.98 26.67 0 0 0 0 0 0 0 0 FbrglsDoor _ _. 0.127 w 3.69-- _ ,3.73 0 0 0 0 . 0 .0 _ 0 0 W ., FrM Wall.bd Knee Wa 0.055 w_,. , 1.6.1 0.76 0 .0 _._0 _. ,0 _0 - 0 0 0 P Frm Wall,1/2_Gyp_B - 0101 2.94, 1.09 0 0 0 0 0 0 0 0 C _ Attic Shngl Roof,R_- 0034. _= _ _ 0.99 1.80 151 151 150 _ - 272 40 40 _ -.39 _ 71- F On Grade Depth,Tile.- 0.989 28.68 0.00 151 26 746 0 ,.- 40 0 0 0 6 c)AED excursion 81 -4 Envelope losstgain 1798 1168 39 68 12 a) Infiltration 482 131 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 250 1 0 Subtotal(lines 6 to 13) 2280 1549 39168 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 17 39 -68 14 Subtotal 2290 1566 0 0 15 Dud loads 28% 35% 645 551 28% 35% 0 0 Total room load 2935 2117 0 0 Air required(cfm) 1 144 108 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -� wrigtitsoft- 2021-Nov-0513:1921 Right-Suite®Universal 2021 21.0.08 RSU27054 Page 6 sUrightsoftHVACl5912 Sunset Blvd PSLPropxp Calc=MJ8 Front Door faces:N i i Air Calcs, LLC Right-J®Worksheet Job: 1300 Date: Aug 06,2020 House i By. Vicki Lynne Nisa Air Calcs, LLC i 7550 Hidden Hammock Ln,Vero Beady FL32966 Phone:772.800.8413 Email:,,icldlyrre@aircaics.com 1 Room name DRXjt 2 Exposed well 23.5 ft 3 Room height 9.5 It heall000l 4 Room dimensions 1.0 x 256.3 ft 5 Room area 256.3 ftz Ty Construction U-value Or HTM Area (ft) Load Area Load number (BtuhAt'--°F) (BtuhAt) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 VI/ Blk Wall,Shi000 Ext 0.109 n 3.15 2.02 0 0 0 0 _._-(' Impacl Clear Lowe. Ob80 n 16.82. ..11,37 -.0-_ _ _,0 . 0 .: 0 Blk Wall,Stucco Ext 0.109 a 3.15 2.02 223 175 550 352 Impact Clear Lowe 0.580 a 16.82 27.57 9 0 151 248 11 Impact,Clear Lowe 0.580 a 16.82 27.57 0 0 0 0 Imnad Clear Low-e,_ 1.650 _e 18..85 32.19 __- 40. 0 746 _. -1275 W_ Blk Wall,Stucco EA - 0.1.09 s 3.15_ _ 2.02 00 0 0 _ Blk Wall,Stucco 6d 0.109 w 3.15 2.02 0 0 0 0 Impact,Clear Lowe 0.620 w 17.98 26.67 0 0 0 0 Impact Clear Low-e 0.620 w 17.98 26.67 0 0 0 0 FbrglsDoor _-_ 0.127 w 3.69 3.73 _ 0 0 - 0 0 W Fmn Wall Ed Knee Wa 0.055 _w 1.61 0.76 0 0 0 . 0 P _ Frm Wall,-1f2"Gyp.B 0.101 2.94 1.09 0 0 0 0 C _ _ Atha Shngl Roof,R 0.034 -.- _0,99._. 1.80 256 _ 256 - _ 254 462_ F_ _._ On,Grade Depth,Tile U89 - 28.68 0.00 256 - _. _ 24 674 0 I - - 6 c)AED excursion -187 Envelope losstgain 2376 2150 12 a) Infiltration 505 137 b) Room ventilation 0 0 13 Intemal gains Occupants @ 230 2 460 Applianoes(other 1700 Subtotal(lines 6 to 13) 2881 4447 Less e)temal load 0 0 Less transfer 0 0 Redistribution 9 16 14 Subtotal 2890 4463 151 Dudloads 1 28% 35% 814 1571 Total room load 3703 6034 Air required(cfm) 1 1 181 309 i Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -*Ir cur➢ghtsoft- 2021-Nov-0513:19:21 Right-Suite@ Universal2021 21.0.08 RSU27054 Page 7 sUrightsoft HVAC\5912 Suset Blvd PSL Prop.nip Calc=MJ8 Front Door faces:N Job: 1300 !Air Calcs, LLC Duct System Summary Date: Aug 06,2020 House By. Vicki Lynne Nisa Air Calcs, LLC i 7550 Hidden Hammock Ln,Vero Beadi,FL32966 Phone:772.800.8413 Email:vicWlyme@aircalcs.com i I Project Information For: Shockley Residence,Air Conditioning Unlimited 5912 Sunset Blvd,Fort Pierce,FL 34982 Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.70 in H2O 0.70 in H2O Supply/return available pressure 0.574/0.126 in H2O 0.574/0.126 in H2O Lowestfriction rate 0.167 in/100ft 0.167 in/100ft Actual airflow 933 cfrn 933 cfin Total effective length(TEL) 420 ft SupplyBranch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk �I Bath h 587 34 17 0.168 4.0 Ox 0 VIFx 41.6 300.0 st3 Bed 2 h 2935 172 130 0.169 8.0 Ox 0 VIFx 40.0 300.0 st3 Bed 3 h 2896 170 128 0.167 8.0 Ox 0 VIFx 44.7 300.0 st3 DWt c 3017 109 185 0.254 7.0 Ox0 VIFx 26.4 200.0 st1 DRxit-A c 3017 109 185 0.253 7.0 Ox 0 V1Fx 27.1 200.0 st1 Great Room c 2363 117 145 0.252 7.0 OXO VIFx 28.3 200.0 st1 Great Room-A c 2363 117 145 0.255 7.0 Ox 0 VIFx 25.1 200.0 st1 M Bath h 1390 82 32 0.271 6.0 Ox 0 VI Fx 12.2 200.0 st2 MasterBedroom h 2677 157 136 0.265 7.0 Ox0 VIFx 16.9 200.0 st2 WIC h 900 53 17 0.269 4.0 Ox 0 VIFx 13.4 200.0 st2 I SupplyDetail Table I ' Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 PeakAVF 377 275 0.167 690 10.0 0 x 0 VinlFlx SO st1 PeakAVF 829 935 0.167 875 14.0 0 x 0 VinlFlx st2 PeakAVF 291 185 0.265 660 9.0 0 x 0 VinlFlx A&- wrightsoftm 2021-Nov-05 13:19:22 .aw•,o t.,.. n.,�, RghtSdte@ universal 2021 21.0.08 RSU27054 Page 1 �� .s\W dghtsoft HVAC15912 Suset Blvd PSL Prop.np Calc=MJ8 Frort Door faces:N i i Return Branch • Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (Cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb5 Ox 0 172 130 75.4 0.167 493 8.0 Ox 0 VI Fx rt1 rb6 Ox 0 170 128 74.5 0.168 487 8.0 Ox 0 VI Fx rt1 rb7 Ox 0 210 153 39.7 0.316 601 8.0 Ox 0 VI Fx rb4 Ox 0 568 710 72.0 0.174 508 16.0 Ox 0 VI Fx rt1 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rt1 PeakAVF 910 967 0.167 547 18.0 0 x 0 VinlFlx I i I I i -lii-wrightsofta 2021-Nov-0513:19:22 RiglI-SUte®Urrversal202121.0.08RSU27054 Page .s\WogNsoftWACt5912Suset Blvd PSLPropnp Calc=MJ8 Fror6Doorfaces:N i i i Job: 1300 Air Calcs, LLC Manual S Compliance Report Date: Aug 06,2020 House By. Vicki Lynne Nisa i Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Emall:,Addlynne@aircalcs.com I Project Information For: Shockley Residence,Air Conditioning Unlimited 5912 Sunset Blvd,Fort Pierce,FL 34982 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 18970 Btuh Entering coil DB: 76.7°F Outdoor design WB: 77.4°F Latent gain: 5434 Btuh Entering coil WB: 63.9°F Indoor design DB: 75.0°F Total gain: 24404 Btuh Indoor RH: 50% Estimated airflow: 933 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Goodman Mfg. Model: GSX16S301A+ASPT39C14A Actual airflow: 933 cfm Sensible capacity: 19600 Btuh 103%of load Latent capacity: 8400 Btuh 155%of load Total capacity: 28000 Btuh 115%ofload SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 41.0°F Heat loss: 20437 Btuh Entering coil DB: 68.2°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Elecstrip Manufacturer. Model: Actual airflow: 933 cfm Output capacity: 5.6 kW 93%of load Temp.rise: 50 °F Meets all requirements ofACCA Manual S. i I ti Wrvghtsoft® 2021-Nov-0513:19:22 ^. ,nw•ie« �eur �p, Right-Sate®Universal 2021 21.0.08 RSU27054 Page 1 �'� ...MrighisoftHVAQ5912Suset Blvd PSLPropnQ Calc=W8 FrontDoorfaces:N _I N Le-11 i 189 Cm 1flt Jn 31'--. e<vy .c.u.. � Q PP AL WALL SECTION Q R.tQx^ - LL a a � O a w Cr _ F FLOOR PLAN C �1 u o i( Job#: 1300 Scale: 1 :229 Performed by Vicki Lynne Nisa for: Air Calcs, LLC Page 1 Shockley Residence 7550 Hidden Hammock Ln Right-Suite®Universal 2021 5912 Sunset Blvd Vero Beach,FL 32966 21.0.08 RSU27054 Fort Pierce,FL 34982 Phone:772.800.8413 2021-Nov-0513:18:46 vickilynne@aircalcs.com AC\5912 Sunset Blvd PSL Prop.rup I FORM R40,-�-2017 . RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance)Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include: ❑ This Checklist ❑ A FORM 405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page). ❑ An input summary checklist that can be used for field verification(usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) ;Required prior to CO for the Performance method: i ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table 402.4.1.1 -one page) i I ❑ A completed Form 2017 Envelope Leakage Test Report(usually one page). Section R402.4 or R402.4.1.2 f exceptions may apply. I ❑ If FORM R405 duct leakage type indicates anything other than "default leakage" then a completed FORM R405 Duct Leakage Test Report(usually one page). I —rYF wrightSaftO Rig Universal 2021 21.0.08 RSU27054 Rig Florida 2017 Section 405.4.1 compliant SoftA el Nov-05 13Page ff Page 1 ...s\Wnghtsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJS Front Door faces: N I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Shockley Residence Builder Name: PSL Prop Street: 5912 Sunset Blvd Permit Office: City,State,Zip: Fort Pierce,FL 34982 Permit Number: Owner: Shockley Residence Jurisdiction: St Lucie Design Location: FL,St Lucie Co Intl County: St Lucie(Florida Climate Zone 2) .New construction or existing New(From Plans) 9. Wall types (1427 ft2) Insulation(R) Area(ft2) 2.Single family or multiple family Single-Family a. Blk Wall,Stucco Ext,R-4.1 Ext 4.1 1136.10 1 b. Frm Wall,1/2"Gyp.Bd Ext,R-11 11.0 281.67 3.Number of units,if multiple family 1 c. Frm Wall Ext Knee Wall,Stucco E 30.0 9.00 4.Number of bedrooms 3 d. N/A 1 10. Ceiling types (1232 ft2) Insulation(R) Area(ft2) 5.Is this a worst case? Yes a. Attic,Shngl Roof,R-30 Ceil Ins 30.0 1232.25 6. Conditioned floor area above grade(ft2) 1232.25 b. N/A Conditioned floor area below grade(ft2) 0 c. N/A 7. Windows 131 ft2 Description A ft2 11.Ducts R Area(ft2) ( ) Area( ) a Sup:House Attic,Ret:House Attic,AH:Uncond Garage 6.0 260.38 a.U-Factor: Sgl Impact,0.580 44.20 b. SHGC: 0.24 b.U-Factor: Sgl Impact,0.620 46.80 12.Cooling systems kBtu/hr Efficiency SHGC: 0.22 a.Split air conditioner 28.0 SEER:15.5 c.U-Factor: Sgl Impact,0.650 39.60 b• SHGC: 0.21 13.Heating systems kBtu/hr Efficiency d.U-Factor: a.Electric strip 19.1 AFUE:100.0 SHGC: b• Area Weighted Average Overhang Depth: 1.000 ft 14.Hot water systems Area Weighted Average SHGC: 0.224 a.Electric conventional(40 gal) Cap:40 gal EF:0.96 8. Floor types(1232.25 ft2) Insulation(R) Area(ft2) b.Conservation features a. On Grade Depth,Tile Fir Fnsh 0.0 1232.25 (None) b. N/A c. N/A 15.Credits None (Glass/Floor area: 0.106 Total Proposed Modified Loads: 43.35 pggS Total Baseline Loads: 44.38 I hereby certify that the plans and specifications covered by Review of the plans and specifications 'tVIE Sf this calculation are in compliance with the Florida Energy covered by this calculation indicates p� 4 compliance with the Florida Energy �' �,,�•' -a �.c•. Code. Code.Before construction is completed, �i 'L , °,,'" PREPARED BY: this building will be inspected for war:. �f • compliance with Section 553.908 " �= DATE: 11/05/2021 67 Florida Statutes. ' I hereby certify that this building,as d gn -,is in compliance with the Florida En rg od cQD H� 4 OWNER/AG NT: BUILDING OFFICIAL: DATE: DATE: I -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). 2021-Nov-05 13:10:42 wrightsoft Right-Suite@ Universal2021 21.0.08 RSU27054 Right-Energy@ Florida2017 Section405.4.1 Compliant Software Paget ,lutdv ln�i.e.t,�empq ...s\Wrightsoft HVAC15912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N I FORM R405-2017 Building Input Summary Report PROJECT Title: Shockley Residence Bedrooms: 3 Address type: Street address Building Type: FLAsBullt Bathrooms: 2 Loft Owner: Shockley Residence Conditioned Area: 1232 Block/Subdivision: #of Units: 1 Total Stories: 1 Platbook: Builder Name: PSL Prop Worst Case: Yes Street: 5912 Sunset Blvd Permit Office: Rotate An le: 0 County: St Lucie Jurisdiction: St Lucie Cross Ventilation: No City, State,Zip: Fort Pierce, FL 34982 Family Type: Single-Family Whole House Fan: No New/Existing: New(From Plans) Terrain: Ocean/Lake Year Construct: Shielding: Suburban Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp ✓ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,St Lucie Cc Intl FL-Fort-Pierce 2 41 90 70 75 486 57 Low BLOCKS # Name Area Volume 1 House 1232.25 ft2 10827.58 ft3 SPACES # Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 WIC 28.88 ft2 236.77 ft3 No 0 0 1 Yes Yes Yes 2 M Bath 44.00 ft2 360.80 ft' No 0 0 1 Yes Yes Yes 3 Master Bedroom 178.88 ft2 1466.77 ft' No 0 1 1 Yes Yes Yes 4 Foyer 42.00 ft2 399.00 ft3 No 0 0 1 Yes Yes Yes 5 Pantry 14.00 ft2 114.80 ft3 No 0 0 1 Yes Yes Yes 6 Great Room 258.00 ft2 2451.00 fe No 2 0 1 Yes Yes Yes 7 Bath 46.75 ft2 383.35 ft3 No 0 0 1 Yes Yes Yes 8 Lin 6.00 ft2 49.20 ft' No 0 0 1 Yes Yes Yes 9 Bed 3 167.13 ft2 1370.42 ft' No 0 1 1 Yes Yes Yes 10 Bed 2 150.88 ft2 1237.17 ft3 No 0 1 1 Yes Yes Yes 11 Hall 39.50 ft2 323.90 ft3 No 0 0 1 Yes Yes Yes 12 DR/Kit 256.25 ft2 2434.38 ft' Yes 2 0 1 Yes Yes Yes FLOORS (Total Exposed Area=1232 sq.ft.) ✓ # Floor Type Space Perimeter R-Value Area LI-Factor Tile Wood Carpet 1 On Grade Depth,Tile Fir Fnsh WIC 11 ft 0 28.88 ft2 0.989 1.0 0 0 2 On Grade Depth,Tile Flr Fnsh M Bath 14 ft 0 44.00 ft2 0.989 1.0 0 0 3 On Grade Depth,Tile Flr Fnsh Master Bedroom 27 ft 0 178.88 ft2 0.989 1.0 0 0 j 4 On Grade Depth,Tile Fir Fnsh Foyer 13 ft 0 42.00 ft2 0.989 1.0 0 0 5 On Grade Depth,Tile Fir Fnsh Pantry 0 ft 0 14.00 ft2 0.989 1.0 0 0 6 On Grade Depth,Tile Fir Fnsh Great Room 20 ft 0 258.00 ft2 0.989 1.0 0 0 7 On Grade Depth,Tile Fir Fnsh Bath 6 ft 0 46.75 ft2 0.989 1.0 0 0 8 On Grade Depth,Tile Fir Fnsh Lin 0 ft 0 6.00 ft2 0.989 1.0 0 0 9 On Grade Depth,Tile Fir Fnsh Bed 3 26 ft 0 167.13 ft2 0.989 1.0 0 0 10 On Grade Depth,Tile Fir Fnsh Bed 2 26 ft 0 150.88 ft2 0.989 1.0 0 0 11 On Grade Depth,Tile Fir Fnsh Hall 0 ft 0 39.50 ft2 0.989 1.0 0 0 12 On Grade Depth,Tile Fir Fnsh DR/Kit 24 ft 0 256.25 ft2 0.989 1.0 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch ✓ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip RoofAsph 1378 ft2 Medium 0.75 No 0.90 No 0 27 2 Hip RoofAsph 441 ft2 Medium 0.75 No 0.90 No 0 27 ATTIC ✓ # TVpe Ventilation Vent Ratio 1 in Area RBS IRCC 1 Full attic Vented 300 1232.25ft2 N N 2 Full attic Vented 300 394.25 ft2 N N 2021-Nov-05 13:10:42 W1q9htS0ft" Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy@ Florida 2017 Section 405.4.1 Compliant Software Page 3 eu1.t•1lvWi. fa+vr ...s\Wnghtsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N FORM R405-2017 CEILING (Total Exposed Area=1232 sq.ft.) ✓ # Ceiling Type Space R-Value U-Factor Area Framing Fraction Truss Type 1 Attic,Shngl Roof,R-30 Cell Ins, 1/ WIC 30 0.034 28.88 ft2 0.10 Wood 2 Attic,Shngl Roof,R-30 Cell Ins, 1/ M Bath 30 0.034 44.00 ft2 0.10 Wood 3 Attic,Shngl Roof,R-30 Cell Ins, 1/Master Bedroom 30 0.034 178.88 ft2 0.10 Wood 4 Attic,Shngl Roof,R-30 Cell Ins,1/ Foyer 30 0.034 42.00 ft2 0.10 Wood 5 Attic,Shngl Roof,R-30 Cell Ins,1/ Pantry 30 0.034 14.00 ft 0.10 Wood 6 Attic,Shngl Roof,R-30 Ceil Ins,I Great Room 30 0,034 258.00 ft2 0.10 Wood 7 Attic,Shngl Roof,R-30 Cell Ins,1l Bath 30 0.034 46.75 ft2 0.10 Wood 8 Attic,Shngl Roof,R-30 Cell Ins, 1/ Lin 30 0.034 6.00 ft2 0.10 Wood 9 Attic,Shngl Roof,R-30 Cell Ins, 1/ Bed 3 30 0.034 167.13 ft2 0.10 Wood 10 Attic,Shngl Roof,R-30 Cell Ins, 1/ Bed 2 30 0.034 150.88 ft20.10 Wood 11 Attic,Shngl Roof,R-30 Cell Ins, 1/ Hall 30 0.034 39.50 ft2 0.10 Wood 12 Attic,Shngl Roof,R-30 Cell Ins,1/ DR/Kit 30 0.034 256.25 ft2 0.10 Wood WALLS (Total Exposed Area=1427 sq.ft.) Adjacent Cavity Width Height Sheathing U- Frm. Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Factor Frac. Absor. Grade% 1 N Exterior Blk Wall,Stucco WIC 0 5 3 8 2 43.0 ft2 4 0.109 0.22 0.60 0 2 - Partition Frm Wall, 1/2"Gy WIC 11 5 6 8 2 45.1 ft2 0 0.101 0.25 0.60 0 3 N Exterior Blk Wall,Stucco M Bath 0 8 0 8 2 65.6 ft2 4 0.109 0.22 0.60 0 4 E Exterior Blk Wall,Stucco M Bath 0 5 6 8 2 45.1 ft2 4 0.109 0.22 0.60 0 5 E Exterior Blk Wall Stucco Master Bedroom 0 13 6 8 2 110.7 ft2 4 0.109 0.22 0.60 0 6 - Partition Frm Walt, 1/2"GyMaster Bedroom 11 13 6 8 2 110.7 ft2 0 0.101 0.25 0.60 0 7 W Exterior Blk Wall,Stucco Foyer 0 5 1 9 6 48.0 ft2 4 0.109 0.22 0.60 0 8 W Exterior Frm Wall Ext Knee Foyer 30 0 11 9 6 9.0 ft2 0 0.055 0.25 0.60 0 9 - Partition Frm Wall, 1/2"Gy Foyer 11 7 0 9 6 66.5 ft2 0 0.101 0.25 0.60 0 10 W Exterior Blk Wall Stucco Great Room 0 14 0 9 6 133.0 ft2 4 0.109 0.22 0.60 0 11 - Partition Frm Walr,1/2"Gy Great Room 11 6 3 9 6 59.4 ft2 0 0.101 0.25 0.60 0 12 W Exterior Blk Wall,Stucco Bath 0 5 6 8 2 45.1 ft2 4 0.109 0.22 0.60 0 13 E Exterior Blk Wall,Stucco Bed 3 0 13 6 8 2 110.7 ft2 4 0.109 0.22 0.60 0 14 S Exterior Blk Wall,Stucco Bed 3 0 12 0 8 2 98.4 ft2 4 0.109 0.22 0.60 0 15 S Exterior Blk Wall,Stucco Bed 2 0 14 6 8 2 118.9 ft2 4 0.109 0.22 0.60 0 16 W Exterior Blk Wall,Stucco Bed 2 0 11 6 8 2 94.3 ft2 4 0.109 0.22 0.60 0 17 E Exterior Blk Wall,Stucco DR/Kit 0 23 6 9 6 223.3 ft2 4 0.109 0.22 0.60 0 DOORS (Total Exposed Area=21 sq.ft.) ✓ # Ornt Door T e Space Storms U-Value Width Height Area YP P Ft In Ft In 1 W Fbrgls Door Foyer None 0.127 3 0 7 0 21.0 ft2 WINDOWS (Total Exposed Area= 131 sq.ft.) Wall Overhang Interior ✓ # Ornt ID Frame Panes NFRC U-Factor SHGC Impact Area Depth Separation Shade Screening 1 N 3 Metal Single Clear Yes 0.580 0.24 Yes 4.Oft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 2 E 5 Metal Single Clear Yes 0.580 0.24 Yes 15.6ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 3 W 10 Metal Single Clear Yes 0.620 0.22 Yes 31.2ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 4 E 13 Metal Single Clear Yes 0.580 0.24 Yes 15.6ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 5 W 16 Metal Single Clear Yes 0.620 0.22 Yes 15.6ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 6 E 17 Metal Single Clear Yes 0.580 0.24 Yes 9.Oft2 1 ft 0 in 1 ft 0 in Blinds 45` outdoor 2 GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 0 INFILTRATION # Scope Method SLA CFM 50 ELA E LA ACH ACH 50 1 Wholehouse Simplified 0.000392 1263 69.48 130.5 0.53 7.00 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts 1 Electric strip AFUE:100.0 19.1 kBtu/hr 1 s s#1 COOLING SYSTEM ✓ # S stem Type Subtype EfficiencV CapacitV Air Flow SHR Block Ducts 1 Split air conditioner SEER: 15.5 28.0 kBtu/hr 933 cfm 0.70 1 s s#1 HOT WATER SYSTEM F ✓ # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric conventional 0.96 40 gal 60 gal 120°F None Wr7ghffioftO Right-Suite®Universal2021 21.0.08 RSU27054 Right-Energy®Florida2017 Section405.4.1 CompliantSoftwarel Nov-0Nov Page 4 au7a�k,t.�:.me�yr� ...s\Wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJS Front Door faces: N DUCTS Supply -------- - Return----- Air CFM 25 Percent HVAC# # Location R-Value Area Location Area Leakage Type Handler Out Leakage ON RLF Heat Cool 1 House Attic 6.0 260 ft2 House Attic 170 ft2 Default Leakage Uncond Garage (Default) 6.00 1 1 TEMPERATURES Programmable Thermostat: Y Ceiling Fans: Cooling [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Heating [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Venting [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Thermostat Schedule: Florida Building Code,6th Edition Hours Schedule Type 1 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 I I 2021-Nov-05 13:10:42 wrightsoff" Right-Suite®Universal2021 21.0.08 RSU27054 Right-Energy®Florida2017 Section405.4.1 Compliant Software Page eae:,i•f�roe�,u�.,.o�a ...s\Wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N FORM R405-2017 i ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX= 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 1. New(From Plans) 12. Ducts, location &insulation level a.Supply ducts: R 6.0 2. Single-family or multiple-family 2. Single-Family b. Return ducts: R 6.0 c.AHU location: Uncond Garage 3. Number of units, if multiple-family 3. 1 13. Cooling systems Capacity 28.0 4. Number of bedrooms 4. 3 a.Split system: SEER 15.50 b. Single package: SEER 5. Is this a worst case? (yes/no) 5. Yes c. Ground/water source: SEER/COP d. Room unit/PTAC: EER 6. Conditioned floor area (ftz) 6. 1232.25 e. Other: 7.Windows,type and area' 14. Heating systems Capacity 19.1 a. U-Factor: Sg71mpact(Avq), 0.616 a. Split system heat pump: HSPF b. Solar Heat Gain Coefficient(SHGC): 7b. 0.22 b. Single package heat pump: HSPF c.Area (ft2) 7c. 131 c. Electric resistance: COP 100.00 d. Gas furnace, natural gas: AFUE 8. Skylights e. Gas furnace, LPG: AFUE a. U-Factor: 8a. f.Other: b. Solar Heat Gain Coefficient(SHGC): 8b. 15.Water heating systems 9. Floor type, insulation level a. Electric resistance: EF 0.960 a. Slab-on-grade(R-value): 9a. 0.0 b. Gas fired, natrual gas: EF b.Wood, raised (R-value): 9b. c. Gas fired, LPG: EF c. Concrete, raised (R-value) 9c. d.Solar system with tank: EF e. Dedicated heat pump with tank: EF 10 Wall type and insulation: f. Heat recovery unit: HeatRec% a. Exterior: g. Other: 1.Wood frame(Insulation R-value): 10a1. 30 2. Masonry(Insulation R-value): 10a2. 4 16. HVAC credits claimed(Performance Method) b.Adjacent: a. Ceiling fans: 1.Wood frame(Insulation R-value): 10b1. 11 b. Cross ventilation: 2. Masonry(Insulation R-value): 10b2. c.Whole house fan: d. Multizone cooling credit: 11. Ceiling type and insulation level e. Multizone heating credit: a. Under attic(R-value): 11 a. 30.0 f. Programmable thermostat: Yes b. Single assembly(R-value): 11 b. c. Knee walls/skylight walls (R-value) 11 C. i d. Radiant barrier installed 11 d. *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded)in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featur Builder Signature: Date: Address of New Home: 5912 Sunset Blvd City/FL Zip: Fort Pierce, FL 34982 Rig -Nov-0513:10:42 wrightsoft� 9 h t-Suite®Universal 2021 21.0.08 RSU27054 Rig Florida 2017 Section 405.4.1 Compliant Software2021 Page 6 ...s\wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N FORM R405-2017 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5912 Sunset Blvd PERMIT#: Fort Pierce, FL 34982 I MANDATORY REQUIREMENTS -See individual code sections for full details. SECTION R401 GENERAL f R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix RD. 0 R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. M R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. 0 R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127,the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. 13 R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 2021-Nov-05 13:10:42 wrighIsafta Right-Suite®Universal2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 7 s\Wdghtsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N I FORM R405-2017 !MANDATORY REQUIREMENTS -(Continued) R402.4.4 Rooms containing fuel-burning appliances In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1.Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2.Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. 0 R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. 0 R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. in R403.3.2 Sealing(Mandatory). All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. El R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. El R403.3.5 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. 0 R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. i R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. 0 R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. I El R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. b Ri h 2021-Nov-0513:10:42 WIPights®ft 9 t-Suite®Universal202121.0.08RSU27054 Right-Energy®Florida2017 Section Page aH=�•fy ;,me��r� ...s\Wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N I FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) 0 R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1 Storage water heater temperature controls. R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be f rom 100°F to 140°F(38°C to 60oC). R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. El R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water heating system.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation,including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ElR403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet the following criteria: 1.The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2.No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3.If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies,heating and cooling calculation based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY(a) AIRFLOW RATE MAXIMUM CFM CFM/WATT CFM Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm-28.3 L/min. (a)When tested in accordance HVI Standard 916 2021-Nov-05 13:10:42 WrightSOf$° Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida2017 Section405.4.1 Compliant Software Page AVId•,&„b;,e. yr�,j s\Wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N I MANDATORY REQUIREMENTS -(Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1.Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2.When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. ❑ R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. i R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions.Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1.A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2.A variable capacity system sized for optimum performance during base load periods is utilized. 0 R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. 0 R403.9 Snow melt and ice system controls(Mandatory). Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that w ill allow shutoff when the outdoor temperature is above 40oF(4.8°C). i R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. El R403.10.2 Time switches. Time switches or other control methods that can automatically turnoff and on according to a preset schedule shall be installed for heaters and um motors.Heaters and um motors that have built-in time switches shall be in compliance with this pump pump P section. Exceptions: 1.Where public health standards require 24-hour pump operations. 2.Pumps that operate solar-and waste-heat-recovery pool heating systems. 3.Where pumps are powered exclusively from on-site renewable generation. ElR403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2021-Nov-05 13:10:42 wrightsofV Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page10 aKtr•fb y, ,,w •r s\Wrightsoft HVAC15912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N !MANDATORY REQUIREMENTS -(Continued) R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. I ❑ R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS 0 R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception: Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. I I I -wrightSofV Right-Suite@ Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section405.4.1 CompliantSoftwarel Nov-051P�age10:42 11 Auta•13,L4*,&&"6 p,7 ...s\Wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N FORM R405-2017 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Shockley Residence Builder Name PSL Prop Street: 5912 Sunset Blvd Permit Office: City,State,Zip: Fort Pierce,FL 34982 Permit Number: Owner: Shockley Residence Jurisdiction: St Lucie Design Location: FL,St Lucie Cc Intl COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the pp requirements building envelope.The exterior thermal envelope Air-permeable ir-p r mate e insulation shall not be used as a ❑ q contains a continuous barrier.Breaks or joints in the 9 air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit The insulation in any dropped ceiling/soffit shall be aligned with the insulation and any shall be aligned with the air barrier. gaps in the air barrier shall be sealed. ❑ Access openings,drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 El walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows,skylights The space between window/doorjambs and framing, and doors and skylights and framing shall be sealed. ❑ Rim joists are insulated and include an air Rim joists shall be insulated. ❑ Rim joists barrier. Floors(including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed above-garage and edge of insulation. to maintain permanent contact with the underside cantilevered floors) of subfloor decking,or floor framing cavity insulation shall be permitted to be in contact El the top sideof sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space Exposed earth in unvented crawl spaces shall be Where provided in lieu of floor insulation, walls covered with a Class I vapor retarder with insulation shall be permanently attached ❑ overlapping joints taped. to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall ❑ be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that ❑ on installation readily conforms to the available cavity spaces. Garage Air sealing shall be provided between the garage separation and conditioned spaces. ❑ Recessed Recessed light fixtures installed in the building Recessed light fixtures installed in the lighting thermal envelope shall be sealed to the drywall. building thermal envelope shall be airtight ❑ and IC rated. Plumbing and Batt insulation shall be cut neatly to fit around wiring wiring and plumbing in exterior walls,or insulation that on installation readily conforms ❑ to available space shall extend behind piping and wiring. Shower/tub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs exterior wall electrical or communication boxes or air-sealed shall be insulated. ❑ boxes shall be installed. Electrical/phone The air barrier shall be installed behind ❑ box on exterior electrical or communication boxes or airrvsealed walls boxes shall be installed. HVAC register HVAC register boots that penetrate building boots thermal envelope shall be sealed to the subfloor ❑ or drywall. Concealed When required to be sealed,concealed fire sprinklers sprinklers shall only be sealed in a manner that is recommended by the manufacturer. ❑ Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 2021-Nov-05 13:10:42 wrightSoftn Right-Suite@ U niversal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 12 aM a�-y� gwas s\Wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N FORM R405-2017 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: St Lucie Permit Number: Job Information Builder: PSL Prop Community: Lot: Address: 5912 Sunset Blvd Unit: City: Fort Pierce State: FL Zip: 34982 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method. ❑` PRESCRIPTIVE METHOD- The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding ii 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2, The building or dwelling unit shall be tested and.verified as having an air leakage rate of not j ❑ PERFORMANCE or ERI METHOD exceeding the selected ACH(50)value;as shown on;FORM R405-2017(Performance)or R406-2017{ERI),"section labeled as Infiltration,sub-section ACH50. ` ACH(50)specified,on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): x60= 10828 = Method for calculating building volume: CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans ❑ PASS 0 Code software calculated ❑ When ACH(50)is less than 3, Mechanical Ventilation installation El Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported ate pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company - - Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2021-Nov-05 13:10:42 lr`W � hfLS V Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 13 awas-�9 r ...s\Wrightsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N g FORM PA05-2017 Duct Leakage Test Report Residential Perscriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition i Jurisdiction: St Lucie Permit Number: Job Information Builder: PSL Prop Community: Lot: Address: 5912 Sunset Blvd Unit: City: Fort Pierce State: FL Zip: 34982 Duct Leakage Test Results System 1 cfm25 ❑ Prescriptive Method, cfm25(Total) To"qualify as"substantially leak free"Qn Total must be less System 2 cfm25 than or equal to 0.04 if air handler unit is installed. If air handler •unit,is not installed, Qn Total must be less than or equal to System 3 cfm25 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Sum of any Is the air handler unit installed —0.04 on) additional systems cfm25 ❑YES YES(— during testing? 0 NO (<=0.03 on) Total of all systems cfm25 ❑ Performance / ERI Method cfm25(Out or Total) 1232 = To qualify using this method, Qn,must be not greater than the" Total of all Total Conditioned proposed duct leakage Qn specified on Form R405-2017 or systems Square Footage R406-2017. . Leakage Type selected on Form Qn specified on Form R405-2017 R405-2017(Energy Calc)or R406-2017 (Energy Ca/c)or R406-2017 ❑ PASS ❑ FAIL F Default Leakage Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either i individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. Testing Company Company Name: Phone: I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: i i 2021-Nov-05 13:10:42 wilghtSoft" Right-Suite®U niversal 2021 21.0.08 RSU27054 Rig ht-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 14 au:a i r na�aye � s\Wdghtsoft HVAC\5912 Sunset Blvd PSL Prop.rup Calc=MJ8 Front Door faces: N Reference Home Characteristics Shockley Residence Title: 5912 Sunset Blvd PSL Prop TMY City: FL Fort Pierce 115912 Sunset Blvd Fort Pierce, FL 34982 FLBase2017 Above-grade Walls (Uo) 0.084 Above-grade Wall Solar Absorptance 0.75 Above-grade Wall Infared Emittance 0.90 Basement Walls(Uo) n/a Above-grade Floors (Uo) n/a Slab Insulation R-Value 0.0 Ceilings(Uo) 0.030 Roof Solar Absorptance 0.75 Roof Infared Emittance 0.90 Attic Vent Area(ft2) 4.11 Crawls pace Vent Area(ft2) n/a Exposed Masonry Floor Area (ft2) 325.30 Carpet&Pad R-Value 2.0 Door Area(ft2) 40.00 Door U-Factor 0.400 North Window Area (ft2) 32.65 South Window Area (ft2) 32.65 East Window Area(ft2) 32.65 West Window Area(ft2) 32.65 Window U-Factor 0.400 Window SHGC(Heating) 0.2169 Window SHGC(Cooling) 0.2169 ACH50 7.00 Internal Gains*(Btu/day) 59539 Water heater gallons per day 60.00 Water Heater set point temperature 120.00 Water heater efficiency rating 0.95 Labeled Heating System Rating and Efficiency HSPF=8.2 Labeled Cooling System Rating and Efficiency SEER= 14.0 Air Distribution System Efficiency 0.88 Thermostat Type Manual Heating Thermostat Settings 72.0 (All hours) i I i I