HomeMy WebLinkAboutDeferred submittal- engergy cal'csr
OFFICE USE ONLY:
DATE FILED: PERMIT# 2106-0353
REVISION FEE: 0.00 RECEIPT#
PLANNING &DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)462-1553
APPLICATION FOR BUILDING PERMITOeIorred
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Revised energy cals
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: 23299
BUSINESS NAME: WINCHIP CONSTRUCTION INC
QUALIFIERS NAME: STEPHEN E WINCHIP
ADDRESS: 7502 SE SANDPIPER ST D `
CITY: HOeE SOUN STATE: FL ZIP: 33455
PHONE (DAYTIME): (772)545-2220 FAX:
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: Kelly&Kelly architects
ADDRESS: 119 S.W.6th St
CITY: Stuart STATE: FL iipVa
PHONE (DAYTIME): 772.283.3492 FAX:
SLCCC: 9123109
Revised 06130117
- KELLY
KELLY.
t
RESIDENTIAL AND COMMERCIAL ARCHITECTURE
SINCE 1980 REG.# 8341
October 28, 2021
St:.Lucie County Building Department. .
2300 Virginia Avenue.,
Ft: Pierce, Florida 34982
RE::.: ,Lauletta Residence
804.Winters Creek Road
.Palm City; Florida 34900
Permit.Number: 2106-0353
Dear Sir or Madam,
Please note the following regarding the above referenced project:
Plans Examiner Review Comments: .
Comment#1: Furnish 2 sets of engineering truss'plan and truss drawings (cut
sheets) reviewed and approved by the design professional.of record. 107.2.1 of
the FBC 2020 7th Edition.
• Agreed Contractor will submit prior to tie beam inspection.
Comment#2: The energy calculation is missing-the builder information at the top ..
of page one left side: .Review and correct 107.1 FBC2020 7t" Edition.
•' See attached energy calculation.with builder's information.on Pages 1 & 2
Comment#3: The energy calcs indicate a 50 gal gas water heater plans indicate
2 tankless water heaters. Review and correct.
See attached revised energy calculation indicating gas water heater. See
Pages 1 1 of 1 and 5.
Certified by
Kelly y
& .�:
..F f'r.. py
FILEC®
v
' as �'� • .P OC; a� q`^C(�
Gary R. Kelly,, '"°paD��pJ
,.'.,
Architect Reg. #8841'`
GRK/dm
119 S.W. SIXTH STREET STUART, FLORIDA 34994 (112) 2" 3-3492
WWW..KELLYANDKELLYARCHITECTS.COM..
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LAULETTA RESIDENCE Builder Name STEPEN E.WINCHIP
Street: 804 N.W.WINTERS CREEK ROAD Permit Office:
City, State,Zip: PALM CITY, FL,34990 Permit Number:2106-0353
Owner: JOHN&MARGARET LAULETTA Jurisdiction:
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing ' New(From Plans) 10. Wall Types(7430.0 sgft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul, ExteriorR=4.1 6540.00 ft2
b.Interior Frame-Wood, Interior R=11.0 380.00 ft23. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 270.00 fe
4. Number of Bedrooms 5 d.other(see details) R= 240.00 ftz
5. Is this a worst case? No 11. Ceiling Types(5782.0 sgft.) Insulation Area
6. Conditioned floor area above grade(ft� 5782 a. Roof Deck(Unvented) R=20.0 5782.00 flz
Conditioned floor area below grade(ff� 0 b.N/A R= f
c.N/A R= fe
7. Windows(1045.0 sgft.)Description Area 12. Ducts,location&insulation level R ft2
a. U-Factor: Sgl, U=0.65 1045.00 ft2 a.a.Sup:.Attic,Ret:Attic.
SHGC: SHGC=0.25 b.b.Sup:Attic,Ret:Attic.
b. U-Factor: N/A fe c. 1 additional duct system(s) (see details)
SHGC: 13. Cooling Systems kBtu/hr Efficiency
c. U-Factor: N/A fe a.Central Unit 60.0 SEER:16.00
SHGC: b.Central Unit 36.0 SEER.16.00
Area Weighted Average Overhang Depth: 5.945 ft c.Central Unit 36.0 SEER:16.00
Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency
8. Skylights Description Area a.Electric Heat Pump 42.0 HSPF:9.60
U-Factor:(AVG) N/A N/A ft? b.Electric Heat Pump 26.0 HSPF:9.60
SHGC(AVG): N/A Electric Heat Pump 25.0 HSPF:9.60
9. Floor Types Insulation Area 15. Hot a er ys em
a.Natural GasTankless p Ca : 1 gallons
a. Slab-On-Grade Edge Insulation R= 0.0 4332.00 ft2 g
EF:0.590
b. Raised Floor R= 19.0 1450.00 ft2 b.Conservation features
c. NIA R= ft2 None
16. Credits None
Glass/Floor Area:0.181 Total Proposed Modified Loads: 171.26
Total Baseline Loads: 193.45 PASS
I hereby certify that the plans and specifications covered by Review of the plans and
�KEsr
this calculation are in compliance with the Florida specifications covered by this pt< _ A�F
Code. calculation indicates compliance1'
with the Florida Energy Code. fk
PREPARED BY: Ukda STtafrc Before construction is completed
this building will be inspected for
DATE: O� P[1r P��O� compliance with Section 653.908 ;-
Florida Statutes.
I hereby certify that this building,as designed,is in compliance
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors,tested in accordance with ANSI/RESNET/ICC 380,Is not greater than 0.000 Qn for whole hou
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 an i r t
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 4.57 OA . .1.2).
917/2021 9:38:24 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the EnergyPerformance Index,the more efficient the home.
804 N.W. WINTERS CREEK ROAD,PALM CITY,FL,34990
1. New construction or existing New(From Plans) 10. Well Types(7430.0 sgft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,ExteriorR=4.1 6540.00 ft2
b. Interior Frame-Wood, Interior R=11.0 380.00 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Exterior R=19.0 270.00 ft2
4. Number of Bedrooms 5 d.other(see details) R= 240.00 ftz
5. Is this a worst case? No 11. Ceiling Types(5782.0 sgft.) Insulation Area
6. Conditioned floor area above grade(ft2) 5782 a.Roof Deck(Unvented) R=20.0 5782.00 112
b.NIA R= ft2
Conditioned floor area below grade(ft2) 0 c.NIA R= ft2
7. Windows" Description Area 12. Ducts,location&insulation level R if
a. U-Factor: Sgl, U=0.65 1045.00 ft2 a.a.Sup:Attic, Ret:Attic
SHGC: SHGC=0.25 b.b.Sup:Attic,Ret:Attic
b. U-Factor: N/A ft2 c. 1 additional duct system(s) (see details)
SHGC: 13. Cooling Systems kBtu/hr Efficiency
c. U-Factor. N/A fP a.Central Unit 60.0 SEER:16.00
SHGC: b.Central Unit 36.0 SEER:16.00
Area Weighted Average Overhang Depth: 5.945 ft c.Central Unit 36.0 SEER:16.00
Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency
8. Skylights Description Area a.Electric Heat Pump 42.0 HSPF:9.60
U-Factor.(AVG) N/A N/A ft2 b.Electric Heat Pump 25.0 HSPF:9.60
SHGC(AVG): N/A c.Electric Heat Pump 25.0 HSPF:9.60
9. Floor Types Insulation Area 1 :a.
=GasTankless
Cap: 1 gallons
a. Slab-On-Grade Edge Insulation R= 0.0 4332.00 ft2 EF:0.590
b. Raised Floor R= 19.0 1450.00 ft2 b.Conservation features
c. N/A R= ft None
16. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed(or exceeded)
in this home before final inspection. Otherwise,a new EPL Display Card will be completed
based on installed Code compli nit features. 0FKAB S�aTE
Builder Signature: f Date: 24
m WINE R E ROAD i /FL i s
Address of New Home:804 N.W.WINTERS C K R D C Zip: CITY,FL,34990
City/FL P . a
'Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for WE
energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code,Energy Conservation,contact the Florida Building Commission's support staff.
"Label required by Section R303.1.3 of the Florida Building Code,Energy Conservation,if not DEFAULT.
9/7/2021 9:38:32 AM EriergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1
i
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: LAULETTA RESIDENCE Address type: Street Address
Building Type: User Bedrooms: 5 Lot#: —
Owner: JOHN&MARGARET LAULETTA Conditioned Area: 5782 Block/SubDivision: —
Total Stories: 2 PlatBook: --
Builder Name: STEPEN E.WINCHIP Worst Case: No Street: 804 N.W.WINTERS CREEK ROAD
Permit Office: Rotate Angle: 0' County: St.Lucie
Jurisdiction: Cross Ventilation: City,State,Zip: PALM CITY,
Family Type: Detached Whole House Fan: FL,34990
New/Existing: New(From Plans) Terrain: Suburban
Year Construct: Shielding: Suburban
Comment:
CLIMATE
✓Design Design Temp Int Design Temp Heating Design Daily temp
Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
_ FL,Fort Pierce Fl.—VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
—1 Blockl 2852 28620
—2 Blockl 1470 14700
3 Block3 1450 14500
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
—1 ZONE 1 2862 28620 Yes 2 2 Yes Yes Yes
—2 ZONE 2 11470 14700 No 1 1 Yes Yes Yes
3 ZONE 3 1450 14500 No 2 2 Yes Yes Yes
FLOORS (Total Exposed Area = 5782 sq.ft.)
# Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R Value Tile Wood Carpet
_1 Slab-On-Grade Edge Ins ZONE 1 446 0 4332 ft 0.304 — 0.00 0.00 1.00
2 Raised Floor ZONE 3 — — 1450 fY 0.047 19 0.00 0.00 1.00
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
J# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Flat the/slate 6465 ft' 0 ft= Medium N 0.96 No 0.9 No 20 26.57
ATTIC
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 5782 fF N N
9/7/2021 9:38:24 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length
1=Natuls Tank;; Garage 0.59(0.59) 1.00 gal 80 gal 120 deg Standard None 99
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
1 No NA NA NA No NA NA NA None
DUCTS
VDuct -----supply Return Air CFM 25 CFM 25 HVAC#
# Location R-Value Area Location R-Value Area Leakage Type Handier TOT OUT QN RLF Heat Cool
_1 Attic 6.0 385 ft= Attic 6.0 96 ft' Default Leakage ZONE 1 (Default)(Default) 1 1
_2Attic 6.0 385 112 Attic 6.0 96 IF Default Leakage ZONE 2 (Default)(Default) 2 2
_3Att1c 6.0 385 ft2 Attic 6.0 96 ft2 Default Leakage ZONE 3 (Default)(Default) 3 3
TEMPERATURES
Programable Thermostat:N Ceiling Fans:N
Cooling []Jan []Feb []Mar []Apr []May [X]Jun [X]Jul [X]Aug [X]Sep [I Oct []Nov I]Dec
Heating [X]Jan [X]Feb [X]Mar []Apr []May []Jun []Jul []Aug []Sep []Oct [x]Nov [X]Dec
Venting I]Jan []Feb [X]Mar [X]Apr []May [I Jun []Jul []Aug []Sep [X]Oct [X]Nov (]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
_Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
_Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 6B
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
9/7/2021 9:38:24 AM EnergyGaugeG USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 5