HomeMy WebLinkAboutAPPROVED REVISION, DS_KHOV ASPIRE MODEL LEILA MASTER ENGDAp E RUsS COMPANY, INC. Re : T108-86966: ASPIRE AT Dade Truss Company, Inc. 6401 NW 74th Avenue Miami, FL 33166 Tel: (305) 592-8245 Fax: (305) 477-8092 Site Information: Project Customer K HOVNANIAN HOMES Job Name: ASPIRE AT WATERSTONE Lot/Blcck: Model: Leila Site Name. Site Address: 5125 ARMIRA PL St- Zip. FT- PIERCE General Truss Engineering Criteria & Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC20201TP12014 Design Program: 8.42 Feb 10 2021 Hoof Load: 0.0 psf Floor Load: NIA Wind Code: wind Speed: 165 mph This package includes 43 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Dale Truss IDS Seaw 1 09/09121 CJ1 A0238136 2 MOM CJ3 A0238137 3 09109n1 CJ3A A0239138 4 0910921 CJ5 A0238139 5 09109n1 CJSA A0238i40 B 09109121 EJ2 A0238141 7 09/0921 EA A0238142 a 09109Mi EJ7 A0238143 9 MOM HJ2 A0238144 10 0910921 HA A0238145 11 091090 HJ6 A0238146 12 09/09121 HJ7 A0238147 131 09/0921 T01 A0238i48 14 1 0910921 T02 A0238149 15 MOM T03 A0238150 16 0910921 T04 A0238151, 17 0910921 T05 A0239152 18 09/09n1 T06 A0238153 19 0810921 T07 A0239154 201 09/09/21 T08 A0238155 21 1 0910921 T09 A0238156 22 1 09/0921 T10 A0238157 23 MOM T11 A0238158 24 09109n1 T12 A0238159 26 09109n1 T13 A0238180 26 091092i T14 A0238161 No. Date Truss IDS Seal# 27 09109121 T14A A0238162 28 0910921 T15 A0238163 29 0910921 T16 A0238164 30 09N921 T17 A0238165 31 09/0921 T18 A0238166 32 09/0921 T19 A0238167 33 09/09/21 T20 A0238168 34 MOM T21 A0238169 35 0910921 T22 A0238170 36 0910921 T23 A0238171 37 OW921 T24 A0238172 38 09109n1 -25 A0238173 39 09M921 T26 A0239174 40 09/0921 Vol A0238176 41 0910921 V02 A0238176 42 09/0921 V03 A0238177 43 0910821 VO4 A0238178 The truss drawing(s) referenced above have been prepared using MiTek Industries, Inc. engineering software under my direct supervision based on the provided by Dade Truss Company, Inc. of Miami, FL. COMPONENTS MANAGEMENT SYSTEMS INC. CERTIFICATE OF AUTHORIZATION # 30680 6401 NW 74 AVENUE MIAMI, FL 33166 305-592-8245 SALVADOR A. JURADO RE, FLORIDA REGISTRATION # 19939 NOTE: The seal on these drawings indicate acceptance of professional engineering responsibilty for the truss components shown per ANSIITPI 1-2014 Section 2. Digitally signed by Salvador lurado Salvado l=Mc=t15,Florida, 1=Miami, o=C=Components Management Systems Inc, ou=President, c—Salvador rJuradoemaa II= I=sj urado@bcg.bz Date: 2021.09.15 11:19:37 -04'00' Page 1 of 1 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 Job Truss Truss Type aty Ply 34296-4-5 CJ1 JACK TR @ 45 24 1 A0238136 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc Thu Sep 9 13:34:45 2021 Page 1 lO:JbsSUYEphcZuYTshvwE3BRyhOBX-tqW kvZotZoV4wTnVKZ1 ya33T5h?TZpcZK6RNxgyfMX6 -1-0-0 1 0-0 1-0-0 1-0-0 2x4 = NOP2X STP= Plate Offsets (X,Y)-- -(2:0-1-14,0-0-10) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) -0.00 2 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.0'. Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n..a wa BCDL 10.0 Code FBC2020/TP12014 Matnx-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 20 SP No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 1.0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = -8/Mechanical 2 = 125/0-8-0 4 - 9/Mechanical Max Horz 2 = 40(LC 12) Max Uplift 3 = -8(LC 1) 2 = -97(LC 12) Max Grav 3 - 18(LC 12) 2 = 125(LC 1) 4 - 18(LC 3) FORCES. (lb) Max. Comp.IMax. Ten. - All forces 250 (lb) or less except when shown. NOTES- 18) 1) Wind, ASCE 7-16; Vult 165mph 1,3-second gust} Vasd=128mph; TCOL=4.2psf; BCDL=3.0psf; h 15ft; B=45h; L=280; eave=4ft; Cat. II; Exp B; Encl., GCpi=O.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL .1.60 2) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections, 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 8 lb uplift at joint 3 and 97 lb uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale = 1:6.0 PLATES GRIP MT20 244/190 Weight: 5 lb FT = 20% LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type ally Ply 34296-4-5 CJ3 JACK TR @ 45 19 1 A0238137 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:47 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyh0BX- pDeWFp75QIo9nxuS_30gU9otUfr1 i6soOwUciyIMX6 -1-0-03-0-0 , 1 0 00 3-0-0 2x4 = NOP2X STP= Plate Offsets (X,Y)-- [2:0-1-140-0-10] LOADING (psf) SPACING- 2 0-0 CSI. DEFL. in (loc) Vdefl Ltd TCLL 20.0 Plate Grip DOL 1 25 TC 0.14 Vert(LL) 0.01 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.14 Vert(CT) -0.01 2-4 >999 180 BCLL 0.0 Rep Stress Incr YES W B 0.00 Horz(CT) -0.00 3 Na n/a BCDL 10.0 Code FBC20201TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SIP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 52/Mechanical 2 = 18710-8.0 4 = 26/Mechanical Max Horz 2 = 71(LC 12) Max Uplift 3 - .32(LC 12) 2 = -142(LC 12) 4 = -28(LC 8) Max Grav 3 - 54(LC 17) 2 = 187(LC 1) 4 = 52(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second LOAD CASE(S) gust) Vasd=128mph; TCDL=4.2psf; Standard BCDL..3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp 8; Encl., GCpi=0.18; MWFRS (directional) and C C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 2-11-4 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise Indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 3, 142 lb uplift at joint 2 and 28 lb uplift at joint 4. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the buitd.ng designer per ANSI TPI 1 as referenced by the building code.' PLATES MT20 Scale = 1.9 9 GRIP 244 190 Weight' 11 lb F r 20{:¢ SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply 34296-4-5 CJ3A JACK TR @ 45 1 1 A0238138 __ Job Reference (optional) _ Run: 8.420 s Feb 10 202T Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:47 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBx-pDeWFp750Io9nxuS 3QgU9olUgc1i6soQwUayfMx6 3-0-0 3-0-0 3xli = 3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 6clefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vert(ILL) -0.00 1-3 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT; -0.01 1-3 >999 180 BCLL 00 ' Rep Stress Incr YES WB 0.011 Horz(CT; -0.00 2 n.:a n.a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No-2 SOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3.0-0 oc purlins. BOT CHORD Rigid ceNng directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be insta'led during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (b:'size) 1 106%Mechanical 2 = 78?Mechanical 3 = 29. Mechanical Max Horz 1 = 49(LC 12) Max Uplift 1 = -241C 12) 2 = -54C 12) Max Grav 1 = 106(LC 11 2 = 78(LC 1) 3 = 58(LC 3) FORCES. ;Ib'l Max. Comp ,Max. Ten - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. It; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 1 and 54 fb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Scale = 1:9.9 PLATES GRIP MT20 244.190 Weight: 9 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply 34296-4-5 CJ5 JACK TR @ 45 13 1 A0238139 i Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:48 2021 Page 1 I ID:dbsSllYEphcZuYTshvwE3BRyhOBX-HPCsXbglsitfnx W4?ialChhuluzEm9M?04t289yfMX5 1 0 0 5-0-0 , II 1-0-0 5-0-0 Scale = 1:13,7 2x4 = NOP2X STP= Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] LOADING (psf) SPACING- 2-0-0 CSi. DEFL. in (loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) -0.03 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.05 2-4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WS 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Iblsize) 3 - 114/Mechanical 2 253/0-8.0 4 = 46/Mechanical Max Horz 2 = 103(LC 12) Max Uplift 3 = -77(LC 12) 2 = -116(LC 12) Max Grav 3 = 114(LC 17) 2 = 253(LC 1) 4 = 92(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second LOAD CASE(S)Standard gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 4-11-4 zone;C-C for members and forces R MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3 and 116 lb uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." PLATES GRIP MT20 244/190 Weight: 17 .b FT = 20'� SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss (Truss Type Qty Ply A0238140 34296-4-5 CJ5A JACK TR @ 45 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:49 2021 Page 1 ID:JbsSUYEpheZuYTshvwE3BRyhOBx-mbmEkxrNdl ?WP45HZP5ulvE21 IJxVcb8FkPbgbyfMx4 5-0-0 Cols LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) -0.03 1-3 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.07 1-3 >863 180 8CLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC202O/TPI2OI4 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SIP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = ISO/Mechanical 2 = 132/Mechanical 3 = 49/Mechanical Max Horz 1 = 81(LC 12) Max Uplift 1 = -42(LC 12) 2 = -91(LC 12) Max Grav 1 = 180(LC 1) 2 = 132(LC 1) 3 = 98(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=2811; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0- 12 to 3-0-12, Interior(l) 3-0-12 to 4-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capabte of withstanding 42 lb uplift at joint 1 and 91 lb uplift at joint 2. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Scale = 1:13.7 PLATES GRIP MT20 244/190 Weight: 16 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REO NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type aty Ply A0238141 34296-4 5 EJ2 JACK TR 9 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34;50 2021 Page 1 IDJbsSUYEphcZuYTshvwE3BRyhOBX-EoKdyC*OOL7N0EgT77c7H6nK6i9E3rlU088C1yfMX3 1-0-0 2-0-0 1-0-0 2-0-0 2x4 tt=VV 0-8-utBP1 M STP - Plate Offsets (X,Y)-- [2:0-1-14,0-0-10) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) -0.00 2 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) -0.00 2-4 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20201TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No-2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 145/0-8-0 4 = 19/Mechanical 3 = 36/Mechanical Max Horz 2 = 56(LC 12) Max Uplift 2 = -87(LC 12) 3 = -20(LC 9) Max Grav 2 = 145(LC 1) 4 = 38(LC 3) 3 - 38(LC 17) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (10) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 13=451t; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSIfTF1 1. 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 87 lb uplift at joint 2 and 20 lb uplift at joint 3. Scale 1 5" .1' PLATES GRIP MT20 2441190 Weight: 8 lb FT = 20`0 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply 34296.4-5 IEJ4 -1-0-0 1-0-0 Plate Offsets (X,Y)-- [2:0-1-14,0-0-10] JACK TR 4 1 A0238142 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:51 2021 Page 1 ID.JbsSUYEphcZuYTshvwE3BRyhOBX-i t?9cte8eFEeOFfhq$MgKJT961czw5Ri2uiiUyfMX2 4-0-0 _ 4-0-0 2x4 0-8-0(0-1-8) NOP2X STP LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) -0.01 2-4 >999 240 TCPL 7.0 Lumber DOL 1.25 BC 0.15 Vert(CT) -0.02 2-4 a999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20201TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No-2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheath ng directly applied or 4-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ibtsize) 3 = 84r'Mechanical 2 = 219;0 8 0 4 36/Machan'cal Max Horz 2 = 87(LC 12) Max Uplift 3 = -56(LC 12) 2 = -110{LC 12) Max Grav 3 = 85(LC 17) 2 = 219(LC 1) 4 72(LC 3) FORCES. (Ib) Max. Comp. Max. Ten. - Al forces 250 (Ib) or less except when shown. NOTES (8) 1) Wind: ASCE 7.16; Vult=165mph (3-second LOAD CASE(S) gust) Vasd=128mph; TCDL=4.2psf; Standard BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2.0-0 to 3.11.4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 56 lb uplift at joint 3 and 110 lb uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale = 1 11.8 PLATES GRIP MT20 244/190 Weight: 14 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply 34296-4.5 1 EJ7 JACK TR 31 A0238143 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 9.420 s Feb 10 2021 M Tek industries, Inc. Thu Sep 9 13:34:52 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX-AARNNytGvyN5GYgrEXfbMXsXEVHkizLbx dFHwyfMx 1 -1-0-0 7-0-0 1-0-0 7-0-0 3x4 Li NOP2X STP= Plate Offsets (X,Y)-- [2:0-0-13,Edge] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.10 2-4 >773 240 TCDL 7.0 Lumber DOL 1.25 BC 0.48 Vert(CT) -0.18 2-4 >431 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a nla BCDL 10.0 Code FBC20201TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 159/Mechanical 2 = 32410-8-0 4 - 78/Mechanical Max Horz 2 = 136(LC 12) Max Uplift 3 -103(LC 12) 2 = -130(LC 12) Max Grav 3 159(LC 1) 2 = 324(LC 1) 4 - 121(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second LOAD CASE(S) gust) Vasd=128mph; TCDL=4.2psf; Standard BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(l) 2-0-0 to 6-11-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint 3 and 130 lb uplift at joint 2. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale r. 1.18 3 PLATES GRIP MT20 244+190 Weight: 23 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0238144 34296-4-5 HJ2 CORNER JACK 2 1 Job Reference (optional) Run- 8 420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 M Tek Industries, Inc. Thu Sep 9 13:34:53 2021 Page 1 ID:JbsSUYEphcZuY-rshvvvE3BRyhOBX•eN?IaluugGVyuiO2oFAgvlPpSvj7RQbkAMNppMyfMXO -1-5-0 2-9-3 1-5-0 2-9-3 2x4 3.s4 P-2 71 B1 e 4 A L /1a 0-10-15(0-1-8) le _ 1:7.9 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.00 2-4 a999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) -0.00 2-4 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20201TPI2014 Matrix-P Weight: 11 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 36/Mechanical 2 = 236/0-10-15 4 = 32/Mechanical Max Horz 2 = 55(LC 8) Max Uplift 3 - -19(LC 5) 2 = .152(LC 8) Max Grav 3 36(LC 1) 2 = 236(LC 1) 4 = 53(LC 3) FORCES. (lb) Max. Comp./Max. Ten, - All forces 250 (lb) or less except when shown. NOTES (11) 1) Wind: ASCE 7.16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 19 b uplift at joint 3 and 152 lb uplift at joint 2. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 8 lb down and 3 lb up at 1-5-0, and 8 lb down and 3 lb up at 1-5-0 on top chord, and 9 lb down and 3 lb up at 1-5-0, and 9 lb down and 3 lb up at 1-5-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (8). 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI i as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 2-4=-20 Concentrated Loads (lb) Vert: 5=-16(F=-8, B=-8) 6=-18(F= 9, B=-9) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238145 34296-4-5 HJ4 CORNER JACK 1 1 Job Reference (optLonal) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:54 2021 Page 1 10:JbsSUYEphcZuY-FshvwE3BRyhOBx-6ZZ7neyWRZdpVszEMyh3SpxzeJ?dAirtPo6MLcyIMx? -1-5-0 5-7-2 1-5-0 5-7-2 2x4 = 0.10.15(0.1-8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) -0.04 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.33 Vert(CT) -0.08 2-4 >818 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 nla n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-7-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = f 20/Mechanical 2 = 19310-10-15 4 = 50/Mechanical Max Horz 2 - 66(LC 8) Max Uplift 3 = -70(LC 8) 2 - -112(LC 8) Max Grav 3 = 120(LC 1) 2 - 193(LC 1) 4 _ 102(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4h; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 70 lb uplift at joint 3 and 112 lb uplift at joint 2. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Sca'e= 1:130 PLATES GRIP MT20 244+190 Weight: 19 lb FT = 20% Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-5=-54 Trapezoidal Loads (plf) Vert: 5=0(F=27, B=27)-t0-3=-76(F=- 11, B=-11) , 2=-2(F=9, B=9)-to-4=-28(F=-4, B=-4) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 "E. MIAMI FL. 33166 Job Truss Truss Type Qty Ply 3429645 HJ5 CORNER JACK 2 1 A0238146 Job Reference (optional) RLin: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:55 2021 Page 1 1D.JbsSUYEphcZuY-rshvwE3BRyhOBX-al7W?. w8CtIA?YQwgCI_AU2njINKRldgsvuFyfMX_ _ 6-9-6 7-0-14 6-9-6 0-3-8 Scale = 1:15.6 2x4 3 4 2x4 1-5.0(0-1.8) 0.5-5(0.1.8) 7-0-1 -3-8 LOADING Ipsf) SPACING- 2-0-0 CSI. DEFL. in (loc) I,defl Ud PLATES GRIP TCLL 200 Plate Grip DOL 1.25 TC 065 Vert(LL) 0.17 2-6 >492 240 MT20 244/190 TCDL 70 Lumber DOL 1.25 BC 0.52 Vert(CT) -0.18 2-6 >443 180 BOLL 0.0 ' Rep Stress Incr NO WB 0.04 Horz(CT) 0,00 n.a nia BCD- 10.0 Code FBC2020' I P12014 Matrix-SH Weight: 26 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Insta lation guide. REACTIONS. (Wsize) 2 = 226+1-5-0 6 = 302/0-5-5 Max Horz 2 = 94(LC 8) Max Uplift 2 = -200(LC 8) 6 = -206(LC 8) FORCES. (lb, Max. Comp..Wax. Ten. - All forces 250 (lb) or less except when shown. NOTES- 49) 1) Wind: ASCE 7-16; Vuitw165mph (3-second gust) Vasd=128mph; TCDL.4,2psf; BCDL■3,0psf; h-151t; B=45ft; L-28ft; eave=4ft; Cat, II; Exp B; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL 1.60 plate grip DOL 1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI:`TPI 1. 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Gable studs spaced at 2-0-0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in al. areas where a rectangle 3-6-0 tall by 2.0.0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 200 lb uplift at joint 2 and 206 lb uplift at joint 6, 8) In the LOAD CASE(S) section loads appl ed to the face of the truss are noted as front (F) or back (B). 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase 1.25 Uniform Loads (pit) Vert: 1-2=-54 Standard Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-3=-92(F=-19, B=-19) 3=-52(F=-19, B=-19)-to-4= 55(F=-21, B=-21), 2=0(F=10, B=10)-to-5=-35(F--8, B=-8) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss 34296-4-5 HJ7 I I 8 2 t G' - s 2x4 = 0.10.15(0-1-8) Truss Type Oty Ply CORNERJACK 7 1 A0238147 Job Reference (optional) w _ Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:55 2021 Page i IDObsSUYEphcZuYTshvwE3BRyhOBX-al7W? wBCIlf7?YQwgCI_AU81jMAvHFldgsvuFyfMX 5-8-1 9-7-5 9-,1 q-1 5-8-1 3-11-4 0-'2-I2 I Scale 1:20.6 2x4 it ' 4 5 3.54 i 2 3x4 = E 5-8-1 5-8-1 2x4 11 3x4 ,. 9-7-5 9-1 1 3-11-4 -- 0V2- 2 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl Vd TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) -0.02 2-7 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.31 Verl(CT) -0.04 2-7 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.25 Horz(CT) 0 01 6 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No-3 *Except* W3: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 37010-10-15 6 = 583/Mechanical Max Horz 2 = 166(LC 8) Max Uplift 2 145(LC 8) 6 247(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-690/110 BOT CHORD 2-7=-229/639, 6-7=-2291639 WEBS 3-6=-701/252 NOTES- (8) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opst; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psi bottom chard live load nonconcurrent w,th any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 145 lb uplift at joint 2 and 247 lb uplift at joint 6. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard PLATES GRIP MT20 244+190 Weight: 44 lb FT = 20% Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-8=-54 Trapezoidal Loads (pit) Vert: 8=0(F=27, B=27)-to-5=-133(F=-39, B=-39), 2=-2(F=9, B=9)-to-6=-47(F=-14, B=-14) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 -ob Truss Truss Type Qty Ply A0238148 34296-4-5 T01 HIP GIRDER TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 M Tek Industries, Inc. Thu Sep 9 13:34:56 2021 Page 1 ID.JbsSUYEphrZuYTshvwE3BRyhOBX-2xhuCKwmzBtW197dTNjXXNi F57bXejAAsKbTPhylMWz 7-0-0 1180 18-8-0 19-8-0 7-0-0 4-8-0 7-0-0 1-0-0 4x6 110 44 Scale: IT- I 3x6 = 5x6 WB= 3x4 — 4X5 = NOP2X STP= 2x4 I 7-0-0 _ 11-8-0 _ 18-8-0 7-0-0 4-8-0 7-0-0 Plate Offsets (X,Y)-- [1:0-0-14,0-0.21, [2:0.2-12,0-2-4], [3:0-2.13,0.1-14] LOADING (psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL) -0.11 7-8 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.21 7-8 >999 180 BCLL 0.0 " Rep Stress Incr NO W B 0.27 Horz(CT) 0.07 4 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP 225OF 1.9E BOT CHORD 2x4 SP 225OF 1.9E "Except* 82: 2x6 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-7-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 - 1518/Mechanical 4 = 1621/0-8-0 Max Horz 1 - -79(LC 6) Max Uplift 1 - -495(LC 8) 4 - -576(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - Ali forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3431/1105, 2-10=-3005/1029, 3-10=-300511029, 3-4=-3397/1087 BOT CHORD 1-9= 924/3090, 8-9=-920/3086, 7-8=-917/3057, 6-7=-896/3033, 4-6=-900/3038 BOT CHORD 1-9=-924/3090, 8-9=-92013086, 7-8=-917/3057, 6-7=-89613033, 4-6= 900/3038 WEBS 2-8=-146/654, 3-7=-149/698 NOTES- (12) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7.16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.opsf; h=1511; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber D0L=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Refer to girder(s) for truss to truss connections. PLATES MT20 0.8*&-f-8) GRIP 244/190 Weight: 81 lb FT = 20% 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 495 lb uplift at joint i and 576 lb uplift at joint 4. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 199 lb down and 68 lb up at 7.0-0, and 199 lb down and 68 lb up at 11-8-0 on top chord, and 375 lb down and 128 lb up at 7-0.0, and 375 lb down and 128 lb up at 11-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 12) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-134(F=-80), 3-5=-54, 1-8=-20, 7-8=-59(F=-39), 4-7=-20 Concentrated Loads (lb) Vert: 3=-199(F) 8=-375(F) 7=-375(F) 2=-199(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type City Ply A0238149 34296-4-5 T02 GIRDER TR 1 1 Job Reference (optional% Run: 8.420 s Feb 10 2021 Pr nt: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34;57 2021 Page t ID:JbsSUYEphcZuYrshvwE3BRyhOBX-X8FGQgxPkU'NW pi 5Fm3bZdbWuwND0K5_L0x7yfMWy 5-0-12 7-0-0 f 5-0-12 1-11-4 2x4 Scale = 1:19.0 3x4 — #".. I I 2s4 NOP2XW104-8: 5-0-12 7-0-0 5-0-12 1-11-4 Plate Offsets (X,Y)-- [1:0-4-5,0-1-2} LOADING (psf) SPACING- 2-0-0 CS]. DEFL, in (loc) Vdefl Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) -0.18 1-5 >433 240 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.33 1-5 >239 ISO BCLL 0.0 ' Rep Stress Incr NO WB 0.09 Horz(CT) 0.00 nla wa BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP 225OF 1.9E BOT CHORD 2x6 SP DSS WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid calling directly applied or 3-0-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ibdsize) 1 = 822/0-8-0 4 = 1405r'Mechanical Max Horz 1 = 108(LC 8) Max Uplift 1 = -247(LC 8) 4 = -489(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=-2191298, 3-4=-2811100 NOTES- (10) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; save=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonroncurrent with any other live loads. 5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder's) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 247 lb uplift at joint 1 and 489 lb uplift at joint 4. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated loads) 861b down and 44 Ib up at 1-1-1, and 160 lb down and 62 lb up at 3-1-1, and 1498 lb down and 515 lb up at 5-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASEfS) section, loads applied to the face of the truss are noted as front (F) or back (B). 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." PLATES GRIP MT20 244.+190 Weight: 34 lb FT = 20 a LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3:--54, 1-4=-20 Concentrated Loads (lb) Vert: 5-1498(F) 6=-86(F) 7=-160(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job 34296-4-5 Truss Truss Type T03 GIRDER TR Qty Ply A0238150 Job Reference (optional) R.ln* 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:58 2021 Page 1 ID:JbsSUYEphoZuYTshvwE3BRyhOBX-?Kped?yl Vo8E TH?b0rn?c06aXwF?6UmTJe4ZUay1Mwx 21.0.0 1 4 0 4 3.7 7.0.0 11.11 14 15-4-13 18 $•0 20.8-0 21 4.0 24.5.13 30-4-0 31.4-0 0 0 3.7 2.8 9 4•ti 14 3 5 0 3-3 3 2.0-00 4-0 3-1.13 5-10-3 0 0 0-4.0 Scale = 1:57.6 46 = 5-00 FfT 3x8 - 2x4 1 4x4 = 4x4 0-8-0"A 3x4 = 8x10 WB 3x8 = "= US = 0-84 54-14) 2x4 21-0-0 11-11-14 15-4.13 18-8-0 20-8-0 21.4-0 7-0-0 _ 4-11-14 _ _ 3-5-0 3-3-3 2-0-o- 4-� 0-4-0 Plate Offsets (X,Y)-- [2:0-3-12,Edge], [3:0-3-8,0-2-0], [7:0-2-0,0-1-12], [16:0-1-12,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFI_. in floc) Well Ud 1 CLL 20.0 Plate Grip DOL 125 TC 0.62 Vert(LL) -0.27 13 >999 240 TCDL 7.0 Lumber DOL 125 BC 0.81 Vert(CT) -0.49 13 >720 180 BCLL 0.0 Rep Stress Incr NO WS 0.84 Horz(CT) 0.11 9 nla n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP 225OF 1.9E *Except" T314: 2x4 SP No.2 80T CHORD 2x6 SP DSS *Except* B3: 2x6 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-9-7 oc pur'ins. BOT CHORD Rigid ceiling d rectly applied or 6-4-14 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, ;n accordance with Stabilizer ,nstallat-on guide. REACTIONS. (lb/size) 2 2227.+0-8-0 9 = 1611),080 Max Horz 2 = -103(LC 6) Max Upl ft 2 = -773(LC 8) 9 - -571(LC 8) FORCES. (lb) Max. Comp -Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4932/1590, 3-17=-4524/1518, 4-17=-452311518, 4-18=-5005/1681, 5-18- 500511681, 5-19=-5005/1681, 6-19=-5005/1681, 6-7=-309311038, 7-8=.312511036, 8-9=-3367/1120 Continued on page 2 TOP CHORD 2-3=-493211590, 3-17=-452411518, 4-17=-4523/1518, 4-18=-5006/1681 I 5-18=-500511681, 5-19=-5005/1681, 6-19=-5005/1681,6-7=-3093/1038, 7-8=-3125/1036, 8-9=-3367/1120 BOT CHORD 2-16=-1363/4461, 15-16=-1713/5520, 15-20=-171315520, 14-20=-1713/5520, 13-14=-1713/5520, 12-13=-133614373, 11.12=-1336/4373,9.11=-943/3035 WEBS 3-16=-33111229, 6-13=-275/925, 6-11 =-2421/848, 4-13=-753/282, 7-11=-704/2195, 4-14=-133/560, 4-16=-1159/387 NOTES- (11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=150; 8=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 30-4-0 1 9-0-0 PLATES GRIP MT20 244/190 Weight: 170 lb FT = 20% 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 773 lb uplift at joint 2 and 574 lb uplift at joint 9. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 199 lb down and 65 lb up at 7-0-0 on top chord, and 375 lb down and 123 lb up at 7-0-0, and 375 lb down and 123 lb up at 11 -8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0238150 34296-4-5 T03 GIRDER TR 1 > Jab Reference ;.optiona) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc Thu Sep 9 13:34:58 2021 Page 2 ID:JbsSUYEphcZuYTstwwE3BRyhOBX-'2Kped?y1Vo8E TH7.bom')co6aXwF?6JmTJe4ZUayfMWz LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-3=-54, 3-17=-134(F=-80), 6-17=-54, 6-7=-54, 7-10=-54, 2-16=-20, 16-20=-59(F=-39), 9-20=- 20 Concentrated Loads (Ib) Vert: 3=-199(F) 16=-375(F) 20=-375(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238151 34296-4-5 T04 140 "-11 9-0.0 Zo 6-841 3-3-5 HIP TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print- 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:34:59 2021 Page 1 ID:JbsSUYEphczuYTshvwE3BRyhOBX-TWMOrLzfG6G5adsC9VHE90fn3Kb.-r5gdYlg700y(M Ww 21-4-0 4JO5 15-1-8 20-8.0 21-0 24-7-6 30-4-0 31-4-D 6-1-8 5-6 8 0 4=0 3-3-6 5-8-10 ti-O-c 0-4-0 Scale = 1:55.1 Ax6 = 0-8-"-1-8) 3x4 = 3X8 = 3x6 = 3x4 = 0-8-80-1-s) 21-4.0 9-0.0 { 15-1-8 20-8-0 2135 30-4-0 9-0.0 6-1-8 5-6-8 d-7-t 9.0-0 0-0-11 Plate Offsets (X,Y)-- [4:0-3-8,0-2-0],[6:0-3-8,0-2-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) 1/deft L/d TCLL 20.0 Plate Grip DOL 1,25 TC 0.44 Vert(LL) -0.16 2-13 >999 240 TCDL TO Lumber DOL 1.25 BC 0.82 Vert(CT) -0.36 2-13 >976 180 BCLL 0.0 ' Rep Stress Incr YES W B 0.21 Horz(CT) 0.09 8 Na nla BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 HOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-5-4 oc purlins. HOT CHORD Rigid ceiling directly applied or 6-7-14 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1170/0-8-0 8 = 1170/0-8-0 Max Horz 2 = .100(LC 10) Max Uplift 2 = -427(LC 12) 8 = .427(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-14=-2222/913, 3-14=-2183/925, 3-15=-2001/823, 4-15=-1991/833, 4-16=-2192J960, 16-17=-2192/960, 5-17=-21921960, 5-18=-2192/960, 18-19=-2192/960, 6-19=-2192/960, 6-20=-1992/833, 7-20=-20011823, 7-21=-2183/925, 8-21=-2222/913 BOT CHORD 2-13=-770/1991, 12-13=-612/181 1, BOT CHORD 2-13=-770/1991, 12-13=-612/1811, 11-12=-617/1812, 10-11=-617/1812, 8.10=-775/1991 WEBS 4-13=-65/373, 4-12=-201/547, 5.12=-382/236 6-12=-200/545, 6-10=-64/374 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=281t; eave=4ft; Cat. II; Exp B; Encl., GCpi-0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 9-0-6, Exterior(2R) 9-0-6 to 12-0-6, Interior(1) 12-0-6to21-3.10, Exterior(2R) 21-3-10 to 24-3-10, Interlor(1) 24-3-10 to 31-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL 1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. PLATES MT20 GRIP 2441190 Weight: 144lb FT = 20% 71 ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 427 lb uplift at joint 2 and 427 lb uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' LOAD CASE(S) Standard SALVADOR JURADO ME STATE OF FLORIDA REG NO, 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238152 34296-4-5 T05 HIP TR i 1 Job Reference (optional) Run. 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:00 2021 Page 1 IDJbsSUYEphcZuYTshvwE36RyhOBX-xiwP2h H1POyDnRC4DoThDBwCkzDaYLmnyzgYSyfMWv 6-6-5 , 11-0-0 15-2-0 _ 19-4-0 23-9-1 i 30-4-0_ 31-4-,0 6-6-5 4-5-11 4-2-0 4-2-0 4-5-11 6-6-5 ;b Scale-1:54.8 4x4 = 34xa = x4 = 2x4 3Z5 = 3x6 = 2x4 0-8-w-i=8} KaER"W= 3x8 = 6-6-5 11-0-0 19-4-0 23-9-11 30-4-0_ _ 6-6-5 4-5-11 8-4-0 4-5-11 6-6-5 Plate Offsets (X,Y)-- 11:0- 1 -8,Edge], [7:0-1-8,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.55 Vert(LL) -0.15 10-12 >999 240 MT20 244.190 TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.36 10-12 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.26 Horz(CT) 0.09 7 Na n1a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 147 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-1-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-9-5 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 109610-8-0 7 = 1171/0-8-0 Max Horz 1 = -119(LC 10) Max Uplift 1 = -357(LC 12) 7 = -428(LC 12) FORCES, (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-22771874,2-14=-2211/886, 2-3=-18291764, 3-4=-16501736, 4-15=-16481741, 5-15=-1648/741, 5-6=-1826/763, 6-16=-21981885, 7-16=-22621869 BOT CHORD 1-13=-725/2024, 12-13=-725/2024, 11.12=-594/1755, 10-11=-59411755, BOT CHORD 1-13=-725/2024, 12-13=-72512024, 11-12=-594/1755, 10-11=-59411755, 9-10=-73312009, 7-9=-73312009 WEBS 2-12=-4611252, 3-12=-1631486, 4-12=-2671113, 4-10=-269/117, 5-1 0=- 1601484, 6-1 0=-446/244 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=280; eave=4tt; Cat.11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 11-0.0, Exterior(2R) i 1-0-0 to 15-2.0, Interior(1) 15-2-0 to 19-4-0, Exterior(2R) 19-4-0 to 23-9-11, Interior(1) 23-9-11 to 31-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 7. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238153 34296-4-5 T06 HIP TR 1 1 Job Reference (optional) Run 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:01 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX-PvUnFt voiWpcAGaGwJiERk2l8H4JxTvOcJE4vyfMWu 7-7-12 _ 13-0-0 _ 17-4-0 22-8-4 30-4-0 31-4-0 7-7-12 5-4-4 4-4-0 5-4-4 7-7-12 1-0-6 Scale = 1:54.8 46 = 4x4 = Qj��t�•J' 2x4 3x4 = 3x6 = 2x4 I 3x8 = 7-7-12 13-0-0 17-4-0 22-8-4 30-4-0 7-7-12 5-4-4 4-4-0 5-4-4 1 7-7-12 Plate Offsets (X,Y)-- [1:0-1-2,Edge], [3:0-3-8,0-2-0], [6:0-1-8,Edge] LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/de0 L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Vert(LL) -0.13 10-11 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.78 Vert(CT) -0.27 1-12 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.46 Horz(CT) 0.09 6 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 147 lb FT = 200% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheath..ng directly applied or 2-7-4 oc purins. BOT CHORD Rigid ceiling directly appFed or 6-9-6 oc bracing. MiTek recommends that Stabilizers and required cross bracing be instal ed during truss erection, in accordance with Stab lizer Installation guide. REACTIONS. (lb/size) 1 = 1096/0-8-0 6 = 1171r'080 Max Horz 1 =-139(LC 10) Max Uplift i-357(LC 12) 6 =-428(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1 13= 2234/850, 2-13— 2163/865, 2.14=-1658/707, 3-14=-1589/722, 3-15=-1469/708, 15-16=-1469/708, 4-16= 14691708, 4-17=-15891726, 5-17=-1657/710, 5-18=-2150/866, 6-18:-2223/847 BOT CHORD 1-1 2=-696/1980,11.12=-696/1980, BOT CHORD 1-1 2=-696/1980,11.12=-696/1980, 10-11=-450/1468, 9-10=-70611967, 8-9=-70611967, 6-8=-706/1967 WEBS 2-12=0/290, 2-11=-606/292, 3-11=-118/391, 4-10=-1211391, 5-1 0= -591/285, 5-8=0/288 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 13-0-6, Exterior(2E) 13-0-6 to 17-3-10, Exterior(2R) 17-3-10 to 21-6-9, Interior(1) 21-6-9 to 31-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) Alf plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. Im 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 6. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238154 34296-4-5 T07 HIP TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, ' nc. Thu Sep 9 13:35:02 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX-t529TN?XZ1egT4amgegxmeG9eXbV2Ks3EF2ndLyfMWt 15-4-0 8-9-6 15-0-0 15-2 0 21.6-10 30-4-0 31-4-0 8-9-6 6.2-10 0-2 0 8 2 10 8-9.6 1-0-d 0.2-0 Scale = 1:54,8 NBRT%.. 20 4x4 = 3x9 = 3x6 = 2x4 0-81*1-8) 15.4.0 8-9.6 _ 15.0-0 15,L2,t} 21.6- I :1 30-4.0 i B-9-6 6.2,10 0-M 6-2-'0 8-9-6 0-2-0 Plate Offsets (X,Y)-- [1:0-1-2,Edgej LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Weil Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 1.00 Vert(LL) 0.18 1-10 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -0.38 1-10 >931 180 BCLL 0.0 ' Rep Stress Incr YES W B 0.77 Horz(CT) 0.09 5 nr'a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH We,ght: 136lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-11-6 oc bracing. —MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 1096/0-8-0 5 = 1171/0-8-0 Max Horz 1 = -160(LC 10) Max Uplift 1 = -357(LC 12) 5 = -428(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1 -11 =-2179/789, 2-11=-20971808, 2-12=-1482/614, 3-12=-14001632, 3-13=-1400/626, 4-13=-1481/607, 4-14=-20871798, 5-14=-2170/776 BOT CHORD 1 -1 0=-631/1922, 9-10=-63111922, 8-9=-63511912, 7-8=-635/1912, 5-7=-635/1912 WEBS 2-10=01338, 2-9=-742/350, WEBS 2-10=0/338, 2-9=-742/350, 4-9= 731 /345, 4-7=01337, 3-9=-296+812 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3 second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28111; eave=4ft; Cat. II; Exp B; Encl., GCpi=0A8; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 15-2-0, Exterior(2R) 15-2-0 to 19-4-15, Interior(1) 19.4-15 to 31-4-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof I.ve load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 ib uplift at joint 5. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code,' LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238155 34296.4-5 T08 SPECIAL TR 2 1 Job Reference (optional) Run: 8 420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:03 2021 Page 1 ID:JbsSUYEphr-ZuYTshvwE3BRyhOBX-Llcx9109KKmX4E9zOLLAJspP Wx?vngFCTVOK9nyfM Ws - -0-0 5-0-0 9 8 0 .12-2-8 } 19-10-0 I 27-5-8 35-0-0 36-0-0 1-0 5-0-0 4-8-0 2-6-9 7-7-8 7-7-8 7-6-8 1-0-0 Scale = 1:65.1 r 4xfi — L° 15 14 '" " — ' ' — NOP2X STP= NOWC�TP= "_ 3x4 —_ 3x6 = 3x4 = 2xA 0-8-g l-B) 3x4 x 3x4 = 3x4 = 5-0-0 _ 9-8-0 16-3-11 23-4-5 29-9-13_ 5-0-0 4-8-0 6-7-11 7-0-11 6-5-8 Plate Offsets (X,Y)-- [2:0-1-8,Edge], [3:0-2-0,0-2-8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in floc) Well Vd TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) -0.17 11.13 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT)-0.2911-13 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.56 Horz(CT) 0.06 8 nla n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No-2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-4-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-11-0 oc bracing. WEBS 1 Row at midpt 4-15 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = -330/0-8-0 15 193910-8-0 8 = 1076/0-8-0 Max Horz 2 - 162(LC 11) Max Uplift 2 = -451(LC 18) 15 = -686(LC 12) 8 = -398(LC 12) Max Grav 15 = 2115(LC 2) 8 = 1197(LC 18) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2.16=-477/1501,3-16=-47211556, TOP CHORD 2-16=-477/1501, 3-16=-472/1556, 3-17=-38511382, 17-18=-385/1382, 18-19=-385/1382,4-19=-386/1382, 4-5=-1124/425, 5-20=-15221582, 6-20=-14441593, 6-21 =-1 616/640, 7-21 =-1 6941629, 7-22=-2289F751, 8-22=-23451732 BOT CHORD 2-23=-13661498,15-23=-13661498, 14-15=-26311078, 13-14=-423/1453, 12-13=-283/1199,12-24=-28311199, 24-25=-28311199, 1 t-25=-283/1199, 10-11=-620/1911, 8-10= 607/2083 WEBS 3-15=-8721404, 4.15=-2606/844, 4-14— 152/611,5-14=-552l285, 6-13=-67/388, 6-11=-1731709, 7-11=-574/321, 7.10=0/303 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. ll; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2.0-0 , Interior(1) 2-0-0 to 5-0-6, Exterior(213) 5-0-6 to 8-0-6, Interior(1) 8.0-6 to 19-10-0, Exlerior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10.0 to 36-0-0 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3535 5-2-3 PLATES GRIP MT20 244/190 Weight: 171 lb FT = 20% 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 451 lb uplift at joint 2, 686 lb uplift at joint 15 and 398 lb uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO ME STATE OF FLORIDA REG NO, 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss 34296-4-5 T09 {} 7-0-0 Q•{t 7-0-0 Truss Type oty Ply SPECIAL TR 2 A0238156 Job Relerence (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 M Tek Industries, Inc. Thu Sep 9 13:35:04 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX•pUAw31o5euOiOk9x3tPs3MbuLdtWF?M ZXuh[44MWr 11-8-0 12.2.1016-3-11 19-10-0 27-5-7 29-9-12, 35-0-0 36-0-0 4-8-0 0-6- 0 4-1-1 3-6 5 7-7-7 2 4-5 5-2.4 1-0-b 44 5 Scale - 1 65.1 1� 21 22 14 13 iZ 1 1 ids 9'it 'u ' NOP2X STP= N0646STP= b1@Wgtr= 4x4 = 3x6 = 3x4 = W 0-8-gale) 3x4 �1 3x4 // 3x4 = 5-0-0 7-0-0 11-8-0 16-3-11 19-10-0 23-4-5 29-9-12 _35-0-0 i 5-0-0 2-0-0i 4-8-0 4-7-11 3-6-5 3-6-5 6-5-7 5-2-4 Plate Offsets (X,Y)-- [3:0-3-0,0-1-12], [4:0-3-0,0-2-4] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) -0.18 10-12 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.73 Vert(CT) -0.31 10-12 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.66 Horz(CT) 0.06 7 n..a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight. 170 lb FT - 20%, LUMBER - TOP CHORD 2x4 SP No.2 'Except' T3: 2x4 SP 225OF 1.9E BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-1-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = -21610-8-0 14 = 1797/0-8-0 7 = 1104/0-8.0 Max Horz 2 = -162(LC 10) Max Uplift 2 = -346(LC 18) 14 = -620(LC 12) 7 = -409(LC 12) Max Grav 14 = 1973(LC 2) 7 = 1228(LC 18) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-426/11258,15-1(3=-4113/1311, 3-16=-413/1365, 3-17=-15321635, TOP CHORD 2-15=-426/1258, 15-16=-41311311, 3-16=-413/1365, 3.17=-15321635, 4-17=-1532/635, 4-18=-1617/626, 5-1 8=- 1530/640, 5-19=-1695/680, 6-1 9=-1 7731670. 6-20=-2361 /790, 7-20=-24171771 BOTCHORD 2-21=-I1861467,21-22=-1186/467, 14-22=-1186/467, 12-13=-501/1640, 11 -1 2=-324/1267,11-23=-324/1267, 23-24=-324/1267, 10-24=-32411267, 9-10=-655/1979, 7-9=-64212149 WEBS 3-14=-21321835, 4-13=-794/369, 5-12=-77/416, 4-12=-304/167, 5-10= 167/713, 6-10=-566/316, 6-9=01298, 3-13=-556/1759 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=O.18; MWFRS (directionat) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interlor(1) 2-0-0 to 7-0-0, Exterior(2R) 7-0.0 to 10-0-0, Interior(1) 10.0-0 to f 9.10-0, Exterior(2R) 19-10-0 to 22-10-0, Interior(1) 22-10-0 to 36-0-0 zone; porch left exposed;C-C for members and forces & MW FRS for react ons shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer Y Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Prov;de adequate dra nags to prevent water ponding 5) All plates are MT2(] plates unless otherwise indicated 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Ops1 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL 10.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 346 lb uplift at joint 2, 620 lb uplift at joint 14 and 409 lb uplift at joint 7. 9) "This manufactured product is designed as an indiv,dual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAM1 FL, 33166 Job Truss Truss Type Oty Ply 34296-4-5 T10 0- 5-5-0 1-0 5-5-0 A0238157 SPECIAL TR 2 1 Job Reference (optional) Run- 8.420 s Feb 10 2021 Print: 8 420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:05 2021 Page 1 ID:JbsSUYEphcZuYrshvwE3BRyhOBX-Igk15P1 WFKYJLVmOeOHuijleJFgJVwDHRDgyfMWq F 9-0-0 13-8-0 19-10-0 26-0-0 27-1-2 35-0-0 36-0.0 3-7-0 4-8 0 6-2-0 6-2-0 1-1-2 7-10-14 7-0-0 04 — Scale = 1:55.1 " 15 14 ""` — — — NOP2XSTP= N0b%X(PTP= b9FO-W= 3x10 —_ 3x6 = 3x4 3x4 = 2x4 if 30 - 5-0-0 9-0-0 13-8-0 16-3-11 19-10-0� 23-4-5 27-1-2 29-4-1 it 35-0-0 5-0-0 4-0-0 4-8-0 2-7-11 3-6-5 3-6-5 3-8-13 2-3-9 5-7-5 Plate Offsets (X,Y)-- [5:0-2-0,0-2-4], [14:0-3-12,0-1-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Ildefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.88 Vert(LL) -0.17 11-13 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0 29 11-13 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.78 Horz;CT) 0.05 8 nla n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 176 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No,2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-6-15 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = -205/0-8-0 8 = 1101/0-8-0 15 = 178810-8-0 Max Horz 2 = 162(LC 11) Max Uplift 2 = -319(LC 18) 8 - -406(LC 12) 15 = -638(LC 12) Max Grav 8 = 1231(LC 18) 15 = 1953(LC 17) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-16=-400/1186, 3-16=-395/1248, 3-17=-726/300, 4-17=-717/310, 4-18=-639/303, 5-18=-639/303, 5.19=-1629/657, 6-19=-1576/667, TOP CHORD 2.16=-400/1186,3-16=-395/1248, 3-17-726/300, 4-17=-7171310, 4-18=-639/303, 5-18=-639/303, 5.19=-1629/657,6-19=-1576/667, 6-20-1737/716, 7-20=-1801/698, 7-21=-22971763, 8-21=-2370/737 BOT CHORD 2-22=-1100/421,15-22=-1100/421, 14-15= 758/281,13-14=-474/1576, 12.13-310/1248,12-23=-31011248, 23-24=-310/1248, 11-24=-310/1248, 10-11= 596/1860, 8-10=-60012090 WEBS 3-14=-47011568, 6-11=-231/777, 7-11=-524/305, 7-10=-6/338, 6-13=-128/491, 5-13=-252/184, 5-14=-11651465, 3-15=-18631715 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511t; B=45ft; L=28ft; eave=4ft; Cat. ll; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0.0 to 12-0-0, Interior(1) 12-0-0 to 19-10-0, Exterior(2R) 19-10-0 to 22-10-0. Interior(1) 22-10-0 to 36-0-0 zone; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 319 lb uplift at joint 2, 406 lb uplift at joint 8 and 638 lb uplift at joint 15. 9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238158 34296-4-5 T11 SPECIAL TR 2 1 Job Reference (options ) Run; 8.420 s Feb 10 2E21 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:07 2021 Page 1 ID:JbsSUYEphcZuYTshwrE3BRyhOBX-E32w43gNZGyZrTkdB061',_2NYKgIafoOXmYIYy{M Wo 6-8-2 11-0-0 15-8-0 19-10-0 26-0-0 35-0-0 36-010 6-8-2 4-3-14 480 4-2-0 6-2-0 9-0-0 f-0 0 4x4 rrr F Sea e - 1:65 1 zz 15 14 13 is rI 'u N0132X STP= NOC%X6';TP= "IW{n7Q 3x6 = 3x4 = 3x4 3x4 = 2x4 3x4 = 5-0-0 11-0-0 15-8-0 23-4-5 29-4-11 35-0-0 5-0-0 6-0-0 4-8-0 7-8-5 6-0-6 5-7-5 Plate Offsets (X,Y)-- [3.0-1-12,0-1 81. [14:0-2-8,0-1-8) LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) Ildefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 11.25 TC 0.87 Vert(LL) -0.20 11-13 >999 240 MT20 244;190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert1CT) -0.34 11-13 >999 180 BCLL 0.0 ' Rep Stress Incr YES W B 0.73 Horz(CT) 0.06 8 n/a Na BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight; 181 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-7-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = -158/0-8-0 15 = 1731/0-8-0 8 = 1111 /0-8-0 Max Horz 2 = 162(LC 11) Max Uplift 2 = -278(LC 18) 15 = -613(LC 12) 8 = -410(LC 12) Max Grav 15 = 1899(LC 17) 8 = 1245(LC 18) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2.16=-397/1089, 3-16=-390/1171, 3-17=-1061/445, 4-17=-1015/458, 4-18=-939/445, 5-18=-9391445, 5-19=-17151752. 6-19=-1681 /762, TOP CHORD 2-16=-39711089, 3-16-390.1171, 3-17= 1061/445, 4-17=-1015/458, 4-18=-939/445, 5-18=-939 445, 5-19=-1715/752, 6-19-16811762 6-20= 1779/736,7-20=-1844l718. 7- 21--2328/785, 8-21=-2400/759 BOT CHORD 2-22=-1023/423,15-22=-11023/423, 13-14=-453/1587, 12-13=-327.+1260, 12-23=-32711260, 23-24=-327:'l260. 11-24=-32711260, 10 11= 616/1897. 8-1 0=-621/2119 WEBS 3-15=-1977/80113-14= 286/1093. 5-14=-897/320, 5-13=-322/230, 6-13=-238/596, 6-11=-232/805, 7-11-521/309, 7-10=-7/325 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7 16; Vult=165mph ;3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=151t; B-:45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2 0 0 , Interior(1) 2 0.0to 11-0-6, Exteriorl2R) 11-0-6 to 14-0-6, Interior(1) 14-0-6 to 19-10 0, Exterior(2R) 19.10-0 to 22-10-0, Interior(1) 22-10-0 to 36 0-0 zone; porch left exposed;C-C for members and forces & MWFRS for react ons shown; Lumber DOL .1.60 plate gr p DOI. =1.60 3) Building Des gner : Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = I O.Opsf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 278 lb uplift at joint 2, 613 Ib uplift at joint 15 and 410 lb uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0238159 34296-4-5 T12 SPECIAL TR 2 1 Job Reference (optional) Run, 8 420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:08 2021 Page 1 ID.JbsSUYEphcZuYTshvwE3BRyh0BXJFPQjQ418t0p8?2wAuxLOvWD?ytvS1gxdBVSq?yIMWn 10 4 7-9-7 13-0-0 17-8-0 19-10-0 26-0-0 35-0-0 36-0-0 .0 } 7-9-7 5-2-9 4-8-0 2-2-0 6-2 0 9-0-0 1-0-0 Scale = 1:65.1 18(mb W dp1w1S R 3x4 3x4 5-0-0 13-0-0 5-0-0 8-0-0 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL O.0 ' Rep Stress Incr YES BCDL 10.r" Code FBC2020/TP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No-3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rig!d ceiling directly applied or 6-0-0 oc bracing MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size 2 -65?0.8-0 15 - 162110-8-0 8 = 1128r0-8-0 Max Horz 2 = 162(LC 11) Max Uplift 2 = -160(LC 11) 15 = -564(!-C 12) 8 -417(LC 12) Max Grav 2 = 19(LC 21) 15 - 1621(LC 1) 8 = 1128(LC 1) FORCES. (lb) Max- Comp./Max. Ten. - At forces 250 (lb) or less except when shown. TOP CHORD 2-16-3091714, 3-16=-298/860, 3-17=-11851542, 4-17=-1118/558, 4-18-1037/542,18-19=-1037/542, 5 19=-1037/542, 5-6=-1454/749, 44 = 4x4 = 4x4 = 6 31tl9 = 3x6 3" 3x4 = 17-8-0 23-4-5 4-8-0 5-8-5 CSI. DEFL. in (10c) TC 0.88 Vert(LL) -0.11 14-15 BC 0.84 Vert(CT)-0.2214-15 WB 0.74 Horz(CT) 0.06 B Matrix-SH TOP CHORD 2-16=-309/714, 3-16=-2981860, 3-17=-11851542, 4-17=-1118/558, 4-18=-1037/542, 18.19=-1037/542, 5-19=-1037/542, 5-6=-1454/749, 6-20=-15891767,7-20=-1669/749, 7-21=-20761814, 8-21=-2166/788 BOT CHORD 2-22=-712/358, 15-22=-712/358, 14-15=-218/575, 13.14=-429/1334, 12-13=-429/1334,11-12=-354/1180, 10-11=-644/1746, 8-10=-647/1903 WEBS 3-15=-1899/831, 3-14= 1i0/562, 4.14=-441251, 5-14=-466/218, 5-12=-414/249, 6-12=-249/526, 6-11=-2361598, 7-11=-497/309, 7.10=-41340 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15111; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 13-0.0, Exterior(2R) 13-0-0 to 16-0.0, Interior(1) 16-0-0 to 19-10-0 Exterior(2R) 19.10-0 to 22-10.0, InteZr(1) 22-10-0 to 36-0-0 zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 i8 2x4 0.8-9*1=8) 29-4-11 35-0 0 6-0-6 5-7-5 I/dell Ud PLATES GRIP >999 240 MT20 2441190 >999 180 nla n/a Weight: 186 lb FT = 200/6 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 160 lb uplift at joint 2, 564 lb uplift at joint 15 and 417 Ito uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code.' LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type ally Ply A0238160 34296-4-5 T13 HIP TR 2 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:09 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX-ASzoxm4wvAWgo9d7kcSaZ73PrM04BbB5rrF1MRyIMWm 20-0.0 51 0-_0_ 7-d-i1 15.0-0 _ 19-8 0 19- -0 27-7-6 35-0-0 36-0.0 4 Q p Ti-11 7.7.5 4 8-0 0- 0 7-7-6 7-4-10 1-0-0 0-2-0 Scale: 3i 16"=1' 4xs = 4x4 = NOP2X STP= 13 12 ' ' 10 9 NOP2X STP= 0-8-M-1v9) 2x4. 3x4 = 3x6 = M = 2x4 i 0-8-m-iq) 20-0.0 _ 7.4-1' 1 1541 09-8-0 19-ai-5 27-7 35 Q 7-4-11 7-7.5 14-8-0 0-3,-5 74-6 7-4-10 0.0-11 Plate Offsets (X,Y)-- 14.0-3-8 0-2-01.[5:0-2-0 0-2-4] LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 200 Plate Grip DOL 1.25 TC 0.81 Vert(LL) -0.17 12 >999 240 MT2i: 244190 TCDL 7.0 Lumber DOL 1.25 BC 0.78 Vert(CT) -0.37 12-13 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.28 Horz(CT) 0.13 7 n/a nla BCDL 10.0 Code FBC20201TP12014 Matrix-SH Weight: 173 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-2-4 oc bracing. WEBS 1 Row at midpt 3.12, 6.10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1342/0-8-0 7 1342/0-8-0 Max Horz 2 = -160(LC 10) Max Uplift 2 = -483(LC 12) 7 = -483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-14=-268611034, 3-14=-2621/1053, 3-15=-19461836, 4-15=-1850/847, 4-16=-1717/843, 16-17=-17171843, 5-17=-1717/843, 5-18=-1850/847, 6-18=-19461836, 6-19=-2620/1053, 7-19=-2685/1034 TOPCHORD 2-14=-268611034, 3-14=-2621!1053, 3-15=-1946/836, 4-15= 1850r847, 4-16=-17171843, 16-17=-1717'843, 5-17=-1717/843, 5-18=-1850/847, 6-18=-1946/836, 6-19= 2620.1053, 7- 1 9=-2685/1034 BOT CHORD 2-13=-88012398, 12-13=-880 2398. 11-12=-553/1716, 10.11-5531716, 9-10=-884/2397,7-9=-884/2397 WEBS 3-13=0/325, 3-12=-747F353, 4-12=-96/443, 6-9=0 324, 5- 1 0=-1 051443, 6-10=-7461353 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45h: L=28ft: save=4ft; Cat. 11; Exp B; Encl., GCpi=0.18: MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 15.0-6, Exterior(2R) 15-0-6 to 18-0-6, Interior(1) 18-0-6 to 19 11 10. Exterior(2R) 19-11-10to22-11-10, Interior(1) 22-11-10 to 36-0-0 zone;C C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the Bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 7. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO PX STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMII FL. 33166 Job Truss Truss Type Qly Ply A0238161 34296-4-5 T14 HIP TR 2 1 Job Reference (options) R.in: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries Inc Thu Sep 9 13:35:10 2021 Page 1 ID: JbsSUYEphcZuYTshvwE3BRyhOBX-eeXB865YgUeXQJCJIJzp5KcfCmKtwxbE4V?CvtyfMW I 18.0-0 1 0 0 5 t 3 12-3-13 17-0-0 17-q-0 22-8 3 28 10 13 35-0-0 *-010 C Go- 1 3 T 6 2 10 4-8.3 0-6-0 4 8-3 6-2 10 6-f-3 0-6 0-6-0 Scale ■ 1-68,1 5.00 12 4x8 = 6 NOP2X STP= "4 ' ° - � " 14 " `Y NOP2X STP= 0-WWA.8) 3x4 = 46 = 3x8 = 4x6 = 3x4 = 04b9p,�_81 18-0-0 8-9-9 17.0-0 17 :6 0 26-2-7 8-9-9 8-2-7 0-6-0 8-2-7 0-6-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I?dell L/d I CI L 20.0 Pate Grip DOL 1.25 TC OA5 Vert(LL) -126 12-14 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -D.45 12-14 >906 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.72 Horz(CT) 0.11 10 nla n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No-2 BOT CHORD 2x4 SP 225OF 1,9E 'Except' B2: 2x4 SP No.2 WEBS 2x4 SP No-3 BRACING - TOP CHORD Structural wood sheathing d rectly applied or 3-0-7 cc purlins. BOT CHORD Rigid ceiling directly applied or 2.2.0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss ere::tion, In accordance with Stab lizer Installation guide. REACTIONS. (lb/size) 2 - 1342JO-8-0 10 = 1342'0-8-0 Max Horz 2 = -185(LC 10) Max Uplift 2 - .483(LC 12) 10 = -483(LC 12) Max Grav 2 = 1493(LC 17) 10 = 1493(LC 18) FORCES. (lb) Max. Comp., -'Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2 17=-29471972 3-17=-2917;986, 3-4=-2739/906. 4-5=-2671 /917, 5-18-1884/711, 6-18=-18351726, 6 19=-1835f726, 7-19=-1884/711, 7-8=-2671 -916, 8-9=-2740,'906, TOPCHORD 2-17=-2947/972, 3-17=-2917:'986, 3-4=-27391906, 4-5=-2671;'917, 5-18=-1884/711, 6-18=-1835/726, 6-19=-1835/726, 7-1 9=-1 8841711, 7-8=-2671/916,8-9=-2740/906, 9-20=-2917/986,10-20=-2948/972 BOT CHORD 2-16=-82012793, 16-21m-598/2226, 15-21=-598/2226, 15-22=-59812226, 14-22=-598/2226, 14-23--609/2132, 13-23=-609/2132, 13-24=-609/2132, 12-24=-609/2132, 10-12= 830/2655 WEBS 3-16=-293/213, 5-16=-1101639, 5-14=-702/323, 7-14=-7021323, 7-12=-110/639, 9-12=-293/213, 6-14=-389/1208 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuit 165mph ,3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15111; B=45ft; L=28ft; save=4ft; Cat. II; Exp B; Encl., GCpi 0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 Interior(1) 2-0-0 to 17-6-0, Exterior(2R) 17-6-0 io 21-8-15, Interior(1) 21-8-15 to 36-0-0 zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 35.0-0 T� 8-9 9 PLATES GRIP MT20 244/190 Weight: 172 lb FT = 20% 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) - This truss has been designed for a live load of 20.Opsf on the bottom chard in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job 34296-4-5 w.l Truss Truss Type City Ply T14A SPECIAL TR 2 A0238162 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:12 2021 Page 1 I D:JbsSUYEphcZuYTshvwE3BRyhOBX-aOfxZo7pC5uFldLhPkOHAlhzcZ1,IOo2XYpUJzmyfMW j -j-0-0 4-10-13 11-3-4 17-0-0 f8-01020.8-0 23 5 6 27-1-12 9 1 1 35-0-0 36-0 0 00 4-1013 647 5812 -00 2.80 2-9-6 385 11 1 5106 00 5.00 12 4x4 = 4x4 = 6— 7 3x8 3x6 % 23 4 2x4 x� 22 - TL 1 2 NOP2X STP= 21 20 0-W(PA-9) 3x4 = 3x8 = �x4 8 �1�x1Q� 16�� 3x4 5x8 19 15 2x4 i, 2x4 24 3x6 9 3x4 10 2x4 ; 11 1R 2 W13 W 14 400 = Scale = 1:66.5 n 25 0 `13 NOP2X STP= 0-13A(9 -9) 7-2-10 11-3-4 17-0-0 , 20-8-0 , 27-1-12 35-0-0 7-2-10 4-0-10 h 5-8-12 3-8-0 _ 6-5.12 7-10-4 Plate Offsets (X,Y)-- [16:0-5.8,0-3.8],[18:0-5-8,0-3-4j1(20:0-3-4,0-1-8j LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Vert(LL) -0.23 18 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.80 Vert(CT) -0.45 19-20 >925 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.91 Horz(CT) 0.19 12 n'a n:a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight:209 lb FT 2C1{n LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-9-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-4-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 12 = 1342/0-8-0 2 = 1342/0-8-0 Max Horz 2 = 180(LC 11) Max Uplift 12 = -483(LC 12) 2 = -483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-22=-2704/1009,3.22=-2625/1019, 3-4=-2509/944, 4-5=-2384/955, 5-23=-2365/901, 6-23=-2295/917, 6-7=-2145/886, 7-8=-2341/939, 8-24=-2889/1112, 9-24=-2923/1102, 9-10=-2988/1099, 10-11— 2507/957, 11 -25=-2606/980, 12-25=-2664/967 BOT CHORD 12-14=-823/2378, 17-18=-573/2140, BOT CHORD 12-14=-823/2378, 17.18=-573/2140, 16-17=-823/2711, 2-21=-861?2436, 20-21=-643/2034 WEBS 5-21 =-1 10/351, 6-18=-244.-741, 8-16=-215l749, 5-20=-608/258, 18-20=-678/2144, 10-14= 499`219, 14-16=-789/2396, 10-16-631436, 7-17=-336/814, 8-17=-983/431 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design 2) Wind: ASCE 7-16; Vult 165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3,Opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpl=0.18; MWFRS (directional) and C-C Exterior(2E) -1 -0-0 to 2-0-0 , interior(1) 2-0-0 to 17-0-0, Exterior(2E) 17-0-0 to 18-0-0, Exterior(2R) 18-0-0 to 22-2-15, Interior(1) 22-2-15 to 36 0 0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer ' Project engineer responsible for verifying applied roof ;ive load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in al areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provde mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 12 and 483 lb uplift at joint 2. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular build:ng is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 .ob Truss Truss Type Qty Ply A0238163 34296-4-5 T15 COMMON TR 20 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.42n s Feb 10 2021 MiTek Industries Inc. Thu Sep 9 13:35:13 2021 Page 1 ID:JbsS UYEphcZuYTshvwE3BRyhOBX-3DDJn88RzPi 6HmwuzSXwjzEARzLa7lLgmTDSVCyfMW 18-0-0 1.0• 6 12-3-13 17-0 0 17.6.0 221 3 28-10-13 35-0-0 a6-P-P 0 6 I 6 2-10 4.8-3 0-6 D 4 8-3 6-2-10 6-1-3 0 0-6-0 Scale = 1:62.3 4x4 = 5-00 12 6 3x4 18 19 30 3x6 5 7 3x6 4 8 20 Z� 2x4 3 W4 s w2 w3\ w3 17 � \� \ i 20 10 2 1 1 131 11 rn NOP2X STP= 16 15 21 22 14 23 13 24 12 NOP2X STP= 0-8300Dd-8) 3xd = 06 = 3x6 _ 06 = 3x4 f 18-0-0 8.9.9 17_0-0_ 17.-q-6 26.27 35-0-0 8.9.9 8-2-7 0-6-'0 82 7 8-9.9 0-6-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) -0.26 14A 6 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.45 14-16 >906 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.72 Horz(CTi 0.11 10 n/a n/a BCDL 10.0 Code FBC2020.TP12014 Matrix-SH Weight: 172 lb FT = 201/6 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP 2250F 1.9E "Except' 132: 2x4 SP No .2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 3-0 7 oc purlins. B07 CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stab lizer Installation guide. REACTIONS. (lb/size) 2 = 134210-8-0 10 - 1342/0-8 0 Max Horz 2 = -185(LC 10) Max Uplift 2 = -483(LC 12) 10 = -483(LC 12) Max Grav 2 = 1493(LC 17 10 = 1493(LC 18) FORCES. (b) Max. Comp.:Max. Ten. - All forces 250 ('b) or less except when shown. TOP CHORD 2 17=-2947:'986, 3-17=-2917/1002, 3-4=-2739/923, 4-5— 2671/933, 5-18-1884.'732, 6-18=-1835/747, 6 19=-1835/747, 7-19=-1884(732, 7-8=-2671/933, 8-9=-2740/923, TOP CHORD 2-17=-2947/986, 3-17=-2917/1002, 3-4=-2739/923, 4-5=-2671/933, 5-1 8=-1 8841732, 6-18=-I835/747, 6-19=-1835/747, 7-19=-1884/732, 7-8=-2671/933, 8-9=-2740/923, 9-20=-2917/1002,10-20=-2948/986 BOT CHORD 2-16— 839/2793, 16-21=-619.:2226, 15-21=-619/2226, 15-22— 619/2226, 14-22=-619/2226, 14-23= 623/2132, 13-23=-623/2132, 13-24=-623/2132. 12.24=-623/2132, 10-12=-84312655 WEBS 3-16=-293/213, 5-16= 109/639, 5-14=-702/323, 7-14=-702/323, 7-12=-109/639, 9-12=-293/213, 6-14=-388/1208 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL 4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exter or(2E) -1-0 0 to 2-0.0 , Interior(1) 2.0-0 to 17-6-D, Extedor(2R) 17-6-0 to 20-6-0, Interior(1) 20-6-0 to 36-0-0 zone-.C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL 1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 10. 8) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0238164 34296-4-5 T16 HIP TR 2 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:14 2021 Page 1 ID:Jbs$UYEphcZuYTshvwE3BRyhOBX-XPmh U83kiSzvwV4X921GAmFaNjFssRq?7z02eywWh 0 0 7-4-11 15-0-0 20-0-0 27-7-5 35-0-0 3fi-0-0 f 0 7-4-11 7-7-5 5-0-0 7 7-5 7-4-11 1-0-C Scale' 3;16"-' 4x6 = 4x4 = 4 is i 17 NOP2X STP= 13 17 " 10 0 NOP2X STP= 0-8-M-1=9) 2" 3x4 = exa = 3ye= 2x4 0-84A%-1=9) 7-4-11 15-0-0 20-0-0 27-7-5 35-0-0 7 4-11 7-7-5 5-0-0 7-7-5 7-4-11 Plate Offsets (X,Y)-- [4:0-3-8,0-2-0]. [5:0-2-0,0-2-4] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) -0.17 12 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.78 Vert(CT) -0.37 12-13 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.28 Horz(CT) 0.13 7 n/a Na BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 173 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing WEBS 1 Row at micipt 3-12, 6-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 134210-8-0 7 = 1342/0-8-0 Max Horz 2 = 160(LC 11) Max Uplift 2 = -483(LC 12) 7 = -483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-14=-2686/1002, 3-14=-2621/1020, 3-15=-1946/797, 4-15=-1856/810, 4-16=-1717/805, 16-17=-1717/805, 5-17=-1717I805, 5-18=-1858/810, 6-18=-19461797, 6-19=-2620/1020, 7-i 9=-2685/1001 TOP CHORD 2-14=-2686/1002, 3-14=-2621/1020, 3-15-1946/797, 4-15=-1858/810, 4 16=-17171805, 16-17=-1717/805, 5-17=-1717/805, 5-18=-18581810, 6.18=-1946/797, 6-19=-2620/1020, 7 19=-268511001 BOT CHORD 2-13=-844/2398,12-13=-844/2398, 11-12=-516/1716, 10-11=-516/1716, 9-10=-854/2397,7-9= 854/2397 WEBS 3-13=0/325, 3-12=-747/355, 4-12-961443, 5-1 0=-1 04/443, 6-10=-746/355, 6-9=0/324 NOTJES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 8=45ft; L=28ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 15-0-6, Exterior(2R) 15.0-6 to 19-3-4, Interior(1) 19-3-4 to 19-11-10. Exterior(213) 19-11.10 to 24-2-9, Interior(1) 24-2-9 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tali by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 7. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MMIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238165 34296-4-5 717 HIP TR 2 1 Job Reference (optional) Rk,n: 8 420 s Feb 1 C 2021 Print, 8.420 s Feb 10 2021 MiTek Industries, Inc Thu Sep 9 13:35:16 2021 Page 1 I D :J bsSUY EphcZu YTshvwE3 B RyhOBX.Tou SP9AJG KP hSErrea4 E L bsaN BM HKj W 7SR S W6XyfM Wf -D 7-7-12 13-0-0 1760 22-0-0 27-4-4 35-0-0 3 -0 0 -0-0 7-7-12 5-4-4 4-6-0 4-6-0 5-4-4 7-7-12 1-0- Scale: 31'1$-=1, I�1 40 — 3>� = 4xa 4 c 18 NOP2X STP= 14 13 `1 " ;i 11 10 NOP2X STP= 0-8-tk1--12) 2x4 1 M = 43d6 = 33(6 = 2x4 0-8-%Q31-32) 7-7-12 13-0-0 22-0-0 _ 27-4-4 _ 7-7-12 5-4-4 9-0-0 5-4-4 LOADING (psf) SPACING 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(ILL) -0.35 11-13 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 1.00 Vert(CT) -0.62 11-13 >664 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.50 Horz(CT) 0.14 8 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 1342/0-8.0 8 - 1342/0-8-0 Max Horz 2 = -140(LC 10) Max Uplift 2 = -483(LC 12) 8 = -483(LC 12) Max Grav 2 = 1490(LC 17) 8 = 1490(LC 18) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-2916/989, 3-15=-2859/1008, 3-16=-23071846,4-16=-2251/862, 4-17=-21021837, 5.17=-2101/837, 5-18=-2101/837, 6-18=-2102/837, 6-19=-2251/862,7-19=.23081846, 7-20=-2859/1008,8.20=-2916/989 TOP CHORD 2-15=-2916/989, 3-15=-2859/1008, 3-16=-2307/846,4-16=-2251/862, 4.17=-2102/837, 5.17=-2101/837, 5-18=-2101/837, 6-18=-2102/837, 6-19=-2251/862, 7-19=-2308/846, 7.20=-2859/1008,8-20=-2916/989 BOT CHORD 2-14=-826/2709,13-14=-826/2709, 13-21=-65412209, 12-21=-654/2209, 12-22=-654/2209,11-22=-65412209, 10-11 =-837/2605, 8-1 0=-837/2605 WEBS 3-14=0/252, 3-13— 654/290, 4.13=-178/682,5-13=-293/119, 5-11=-2931119, 6.11=-178/682, 7-11=-655/290, 7-10=0/252 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 13.0-0, Exterior(2R) 13-0-0 to 17-6-0, Interior(1) 17-6-0 to 22-0-0, Exterior(2R) 22-0-0 to 26-2-15, Interior(1) 26-2-15 to 36.0.0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 35-0-0 7-7-12 PLATES GRIP MT20 244/190 Weight: 173 lb FT = 20% 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10,0 psf bottom chord live load nonconcurrent with any Other live loads. 7) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oly Ply A0238166 34296-4-5 T18 HIP TR 2 1 Job Reference (opt onal) Run: 8.420 s Feb 10 2021 Pr nt: 8.420 s Feb 10 2021 MiTek Industries, Inc, Thu Sep 9 13:35:17 2021 Page 1 ID:JbsSUYE phcZuYTshvwE3BRyhOBX-x-.SgcVBxleXYmOEtCHbT"Ma W3EzGh5B4ezyfMWe 6-6-5 11-0-0 17-6-0 24-0-0 28-5-11 35-0-0 3 -0-0 .Oy0 0-0 6-6-5 _ f 4-5-11 6 6 0 r 6-6-0 4-5-11 6-6-5 1-0- Scale: 3116"=1' 4%* — 2011 06 _ F nn f NOP2X STP= 15 14 1,1 12 11 10 NOP2X STP= 0-84A-1=6) 2x41 11 3x4 = 3x6 = 3x4 = 2x4 I 0-87M- t=9} 3x8 = 6-6 5 11-0-0 , 17-6-0 24-0-0 _ 28-5-11 35-0-0 , 6-6-5 4-5-11 6-6.0 6-6-0 4-5-11 6-66-6 5 Plate Offsets (X,Y)-- [4:0-3-8,0-2-0],[6:0-3-8,0-2 0],[13:0-2-0,0-1-81 _ LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Vert(Lt) -0.20 12 >999 240 MT20 244.190 TCDL 7.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.38 11-12 >999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.23 Horz(CT) 0.13 8 n/a nra BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 174 lb F i = 20°a LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 20 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-10-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 134210-8-0 8 = 134210-8-0 Max Horz 2 = 120(LC 11) Max Uplift 2 = -483(LC 12) 8 = -483(LC 12) FORCES. (lb) Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-16=-2681/1006, 3-16=-2616/1021, 3-4=-2256/913, 4-17=-2410/1014, 17-18=-241011014,5-18=-2410/1014, 5-19=-2410/1014, 19-20=-2410/1014, 6-20=-2410/1014, 6-7=-2256/913, 7-21 _ 261611021, 8-21=-268111006 BOT CHORD 2-15=-848/2391, 14-15=-848/2391, BOT CHORD 2-15=-848/2391, 14-15=-848/2391, 13-14=-65312036,12-13=-65312036, 11-12=-663/2036,10-11=-857/2391. 8-10=-857/2391 WEBS 3-14=-428/22814-14=-87/368, 4-12=-182/576, 5-12=-403/247, 6-12=-1821576, 6-11=-87/368, 7-11=-429/228 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vuit=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=2611; eave=4ft; Cat. II; Exp B; Encl., GCpi=O.i8-, MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 11 -0-6, Exterior(2R) 11-0-6 to 15-3-4, Interior(1) 15-3-4to 23-11-10, Exterior(2R) 23-11-10to 28-5-11, Interior(l) 28-5-11 to 36-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3 6 0 to I by 2-0 0 wide wil fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 8. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular buildng is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Jab ; Truss Truss Type Qty Ply A0238167 `34296-4-5 T19 HIP TR 2 1 Job Reference (optional) Rrn: 8.42r s Feb 10 2021 Print- 8.420 s Feb 10 2021 MiTek Industries Inc. Thu Sep 9 13:35:18 2021 Page 1 ID:JbsSUYEphcZuY rshvwE3BRyhOBX-PAOCgrBaoxfPNYprm?7iOOxvr-2iod8OwixdBPyfMWd 5-8-11 9-0-0 13-4-12 21-7-4 26-0-0 29-3-5 35-0-0 30-0.0 -0-0 5-8-11 33 3- 4-4-12 r 8-2-8 Y 4-4-12 3-3-5 5-8-11 1-0-0 44 = 5.00 12 3x4 = 4 R 17 3xill = 4x+I = A 18 t Scale: 316"-1 0 NOP2X STP= 14 13 12 11 NOP2X STP= 0-87M-1~9) 3x9 = 4x6 = 0.87M49) 3x4 9-0-0 17-6-0 26-0-0 9-0-0 8-6-0 8-6-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udell Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0.92 Vert(LL) -0.24 12 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.47 12-14 >881 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.49 Horz(CT) 0.14 9 nla n/a BCDL 10.0 Code FBC20201TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No 3 BRACING- TOPCHORD Structural wood sheath ng direct y applied. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing MiTek recommends that Stabil.zers and required cross braving be insta led during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size. 2 1342JO 8 0 9 - 134210-8-0 Max Horz 2 = 100(LC 11) Max Uplift 2 = 483(LC 12) 9 = -483(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-15=-264611023, 15-16=-260611026, 3.16=-255311035, 3-4=-2418/938, 4-5=-2219/899, 5-17=-2828/1106, 17-18=-282811106, 6-18=-2828/1106, 6-7=-22191899, 7-8=-2418/938, B-19=-255311035, 19-20=-2606/1026 9-20=-264611023 BOT CHORD 2-14=-86512377, 13-14=-957/2743, 12-13=-957/2743, 11-12=-950/2743, BOT CHORD 2-14=-865/2377,13-14=-957/2743, 12-13=-957/2743,11-12=-950/2743, 9.11=-875/2377 WEBS 4-14=-2661781,5-14=-772/331, 6-11=-772/331,7-11=-2661781 NOTES- (9) i) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf,, h=15ft; B=450; L=28ft; eave=4ft; Cal. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 . interior(1) 2-0-0 to 9-0-0, Exterior(2R) 9-0-0 to 13-4-12, Interior(1) 13-4-12 to 26-0-0, Exterior(2R) 26-0-0 to 30-2-15, Interior(1) 30-2-15 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 35-0-0 9-0-0 PLATES GRIP MT20 2441190 Weight: 164 lb FT = 200% 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0.0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 483 lb uplift at joint 2 and 483 lb uplift at joint 9. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE- MIAMI FL. 33166 Job Truss Truss Type Qty Ply 34296-4-5 T20 HIP GIRDER TR 2 2 11 A0238168 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:20 2021 Page 1 ID.JbsS'-,YEphtZuYTshvwE3BRyhOBX-LZ8yFxDgJZvBdrzEtODAVROEaolHGUNi N3QkFlyfMWb t}-p�7-0-0 ,_ 14-0-9 20-11-7 28-0-0 _ 35-0-0 36-0-0 Woo-- 7-0-0 7-0-9 6-10-13 7-0-9 7-0.0 I.0 C 5.00, 12 lin:" 2x4 3x6 — 3x4 prvlla Scale: 316"-1' NOP2X STP= 18 17 16 16 14 13 12 11 10 NOP2X STP= 0-8-QM1 ::A 4) 3x10 3x5 0-8-1M1�4) 4x6 — 4x6 = 2x4 2x4 5x8 4x6 � - 4x6 — 20-11-7 7.0-0 14-0-9 19-6-0 20-6-0 28-0-0 35.0-0 7.0-0 7-0-9 5-5-7 1-0-6 7-0-9 7-0.0 0.5.7 Plate Offsets (X,Y)-- (3:0-3-12,0-2-8], [7:0-3-12,0-2-8], [13:0-2-0,0-1-8], [14:0-4-0,0-3-0], [15:0-4-0,0-1-8] _ LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.97 Vert(LL) -0.40 13-15 >999 240 MT20 244.190 TCDL 7.0 Lumber DOL 1.25 BC 0.86 Vert(CT) -0.75 13-15 >550 180 BCLL 0.0 ' Rep Stress Incr NO W B 0.70 Horz(CT) 0.16 8 n/a n/a BCDL 10.0 Code FBC20201TP12014 Matrix-SH Weight: 323 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 "Except" T233: 2x4 SP 2250F 1.9E BOT CHORD 2x4 SP No.2 'Except' 82: 2x6 SP No.2 B4,83: 2x4 SP 225OF 1.9E WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 8-11-9 oc bracing. REACTIONS. (lb/size) 8 = 316110-8-0 2 = 3161 /0.8-0 Max Horz 2 = 80(LC 7) Max Uplift 8 = -1078(LC 8) 2 = -1078(LC 8) FORCES. (lb) Max. Comp.IMax. Ten. - All forces 250 (1b) or less except when shown. TOP CHORD 2-3=-7221/2332,3-4=-9827/3262, 4-5=-9827/3262,5-6=-9827/3262, 6-7=-9829/3263,7-8=-7221/2332 BOT CHORD 2-18=-2041/6539,17-18=-2035/6528, 16-17=-203716540,15-16=-2042/6547, 14-15=-3126/9829, 13-14=-3126/9829, 12-13=-204216546, 11-12=-2036/6540, BOT CHORD 2-18— 2041/6539,17-18=-2035/6528, 16-17=-2037/6540, 15-16=-2042/6547, 14-1 S=-3126/9829, 13-14=-312619829, 12-13= 204216546, 11-12=-2036/6540, 10-11=-2034/6528,8-10=-2041/6539 WEBS 3-17=-1411701, 3-15=-1175/3666, 4-15=-9951411, 6-13=-1017/41 1, 7-13=-1177/3669, 7-11=-141/701 NOTES- (12) 1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: Top chards connected as follows: 2x4 1 row at 0-7-0 oc. Bottom chords connected as follows. 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0 9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3,Opsf; h=15ft; B=45ft; L=28ft; eave=4h; Cat. 11; Exp B; Encl., GCpi=4.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 6) Provide adequate drainage to prevent water ponding. 7) All plates are MT20 plates unless otherwise indicated. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0.0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1078 lb uplift at joint 8 and 1078 lb uplift at joint 2. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 199 lb down and 65 lb up at 7-0-6, and 199 lb down and 65 lb up at 27-11-10 on top chord, and 375 lb down and 123 lb up at 7-0-0, and 375 Ito down and 123 lb up at 28-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMII FL. 33166 Job Truss Truss Type City Ply A0238168 34296-4.5 T20 HIP GIRDER TR 2 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek nd.isires, Inc. Thu Sep 9 13:35:20 2021 Page 2 ID:JbsSUYEphcZuYTshvwE3BRyhOBX--Z6yFXDgJZv6drzE1Q9AV ROEaoIHGUNiN3QkFtyUWb NOTES- (12) 12) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=-134(F=-80), 7-9=-54, 2-17=-20, 11-17=-59(F=-39), 8-11=-20 Concentrated Loads (lb) Vert: 3=-199(F) 7=-199(F) 17=-375(F) 11=-375(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238169 34296-4-5 T21 COMMON TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:21 2021 Page 1 ID-JbsS,)Yk phcZuY-rshvwE3BRyhOBX-glhLStES4slzF?XQR7gP2tZxFB9R?1Hsg9HokylMWa 1-41 04 -11-14 6.0-14 9-4-0 _ 12 7-2 13-8-2 _ 18-8-0 19-8-0, 1-4-0 3-7-14 1-1.0 3-3-2 3-3-2 �� 4-11-14 1-0-0 Scale ■ 1:35,1 40 — 9 3x4 " $ 0112 4x8 = 4x8 = 3x4 = T _ W5 2 3x4 3 10 Cq 2 3 g 11 37 36 f 1 12 cv 13 NOP2 �-LJ FT-1-1 38 19 t8 17 i6 15 14 39 4x6 4x6 = 3x4 = 4xA 44 = 3x4 -':' 3x4 = 4x4 0-8-0(0-1-8) 2-9-13 1 4-0 2 0-1 t - 4-11-14 6o-1.� _ 9 4.0 _ 12-7.2 .13-8-2 , 15-10.3 16-7-� 18-8-0 Y1-1-0 1-4-0 8 ti 2-2-2 i0 9 3-2 3-3-2 2-2-2 0-9-2- 2-07i1 0-9-2 Plate Offsets (X,Y)-- [1:0-1 -4,0-1-15],[1:0-3-13,Edge]. [3:0-4-12,Edge], [4:0-0-8,0-1-8], [7:0-5-0,0-2-8), [9:0-0-8,0-1-8], [10:0-4-12,Edge], [12:0-1 -4,0-1 -15], [12:0-3-13,Edgej LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) Irdefl i.-d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) -0.08 18 >999 240 MT20 244.190 TCDL 7.0 Lumber DOL 1.25 BC 0.61 Vert(CT) 0.15 18 >999 180 BCLL 0.0 " Rep Stress Incr NO WB 0.27 Horz(CT) 0.05 12 n,'a Na BCDL 10.0 Code FBC2020/TPI2014 Matrix-MSH Weight: 128 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-6-4 oc purlins. Except: 1 Row at ml 3-10 BOT CHORD Rigid ceiling directly applied or 7-5-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 943/0-8-0 12 = 100210-8-0 Max Horz 1 = -94(1-C 6) Max Uplift 1 = -307(LC 8) 12 = -362(LC 8) FORCES. (lb) Max. Comp.IMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-36=-21891709, 2-36= 2166/707, 2-3=-2163/706, 3-4=-1582/562, 4-6=-1238/396, 6-9=-1238/396, 9-10=-1580/562, 10-11=-2135/671, 11-37=-2135/670,12-37=-2160/672, TOPCHORD 1-36=-2189/709,2-36=-2166/707, 2-3=-2163/706, 3-4=-1582/562, 4.6=-12381396, 6-9=-1238/396, 9-1 0=-1 580/562, 10-11=-2135/671, 11 -37=-2135/670,12-37=-2160/672, 3-5=-531/129, 8-1 0=-530/1 11 BOT CHORD 1-38=-622/2058,19-38=-622/2058, 18-19=-62612043, 17-18=-574/1993, 16-17=-556/1977, 15-16=-55611977, 14-15=-59212013,14-39=-585/2027, 12-39=-58512027 WEBS 7-9=-371/223,4-7=-377/223, 7-17=-43/495, 5-17=-604/95, 8.17=-579177, 6-7=-1821712 NOTES- (15) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) Provide adequate drainage to prevent water ponding. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 2x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 10) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tali by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 307 lb uplift at joint 1 and 362 lb uplift at joint 12. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Hanger(s) or other connection devices! shall be provided sufficient to support concentrated load(s) 37 lb down and 12 lb up at 2-0-0, and 37 lb down and 12 lb up at 16 8 0 on top chord, and 32 lb down and 10 lb up at 2-0-0, and 32 lb down and 10 lb up at 16-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Continued on page 2 SALVADOR JURADO P,E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0238169 34296-4 5 T21 COMMON TR 1 1 Job Reference (optional) Run: 8 420 s Feb 10 2021 Print: 6.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:21 2021 Page 2 ID:JbsSUYEphcZuYTshvwE3BRyhOBX-glhLStES4s1 zF?X0R7gP22XF89R?1 Hscj9HokyfMWa NOTES (15) 14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front iF) or back (B). 15) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particu•ar bui'ding is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard 1) Dead + Roof Live (balancedi: Lumber Increase= 1 .25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3= 54, 3-6=-54, 6-10=-54, 10-13= 54, 26-38=-20, 38-39=-30(F=-10), 31-39 -20, 3 10=-18(F) Concentrated Loads (Ib) Vert: 36=-37(F) 37=-37(F) 38=-32(F) 39-2(F) SALVADOR JURADO P.E. STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Hype Oty Ply A0238170 34296-4-5 T22 COMMON TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:22 2021 Page i 1 D:JbsSUYEphrZuYTshvwE313Ryh0Bx-IyFjgDF4(A9gs96c?rBeas5'BbRrkVK?rNvrKByfMwz 5 11-10 9-4-0 12-8-6 18-8-0 19-8-0 5-11-10 3-4-6 3-4-6 5-11-10 �1-0 00 Scale: 318"=1' 4x a 3x5 0-8-0co-1-8} 9-4-0 18-8-0 9-4-0� 9-4-0 Plate Offsets ,X,Y)-- [1:0-1-2,Edge1. [7:0-4-0,0-3-01 I LOADING (psf) SPACING- 2-0-0 CSI, DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1 25 TC 0,45 Vert(LL) -0.15 1-7 >999 240 MT20 244.190 TCDL 7.0 Lumber DOL 1.25 BC 0.86 Vert(CT) -0.32 1-7 n685 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.22 Horz(CT) 0 03 5 wa n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 77 lb FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-5-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-10-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 673/Mechanical 5 _ 751/0-8-0 Max Horz 1 = -102(LC 10) Max Uplift i - -218(LC 12) 5 = -291(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-8=-1241/668, 2-8=-1190/678, 2-9=-9521524, 3-9=-942/534, 3-10=-9391524, 4-10=-950/514, 4-11 =-1 169/658, 5-11 1210/645 BOT CHORD 1-7=-52611107, 5-7=-514/1067 WEBS 3-7=-2861579, 4-7=-301/278, WEBS 3-7=-2861579, 4-7=-301 /278, 2-7=-3451307 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45h; L=28ft, eave=4ft: Cat. II; Exp B; Encl.. GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0-12 to 3-0-12, Interior(1) 3-0-12 to 9-4-0, Exterior(2R) 9-4-0 to 12-4-0, Interior(1) 12-4-0 to 19-8-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer 1 Project eng-neer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live :oad of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 218 lb uplift at joint i and 291 lb uplift at joint 5. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the bu Iding designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JIIRADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238171 34296 4-5 T23 GIRDER TR 1 1 Job Reference (optional) Run- 8 420 s Feb 10 2021 Print: 8 420 s Feb 10 2021 MITek Indusir es, Inc. Thu Sep 9 13:35:23 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX-m8p5tZFicUHhUJhpZY074exW?pOT?j93 i eOsdyfMWY 4-0-0 4-0-0 3x4 = 2x4 II 0.8-0(0-1-8) NOP2X STP= Plate Offsets (X,Y)-- [1:0-4-5,0-1-2) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defi ', d TCLL 20.0 Plate Grip DOL 1.25 TC 0.22 Vert(LL) -0.02 1-3 a999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.65 Vert(CT) -0.04 1-3 a999 180 BCLL 0.0 Rep Stress Incr NO WB 0.02 Horz(CT) 0.00 n.:a nla BCDL 100 Code FBC20201TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No 2 BOT CHORD 2x6 SP No 2 WEBS 2x4 SP No 3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD R.gid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stab-lizers and required cross bracing be instafed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. ;Ibtsize) 1 = 46310 8-0 3 = 451 Wechanical Max Horz 1 = 60;LC 8) Max Uplift 1 = -144?1-C 8) 3 = -166(LC 8) FORCES. (lb) Max. Comp.?Max Ten. - All forces 250 (lb) or less except when shown. NOTES (10; 1) Wind: ASCE 7 16: Vult=165mph (3-second gust) Vasd=128mph. TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. If: Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate gr p DOL=1.60 2) Building Designer 1 Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10 0 psf bottom chord live load nonconcurrent with any other live loads. 5) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 144 lb uplift at joint 1 and 166 lb uplift at joint 3. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 653 lb down and 238 lb up at 2-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibii ty of others. 9) In the LOAD CASE(S) section, loads applies to the face of the truss are noted as front (F) o• back (B). 10) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Scale = 1:11.8 PLATES GRIP MT20 2441190 Weight; 18 lb FT = 20% LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-2=-54, 1-3=-20 Concentrated Loads (lb) Vert: 4=-653(F) SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job 34296-4-5 Truss Truss Type Oty Ply A0238172 T24 COMMON TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:24 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX-EKNT4uGKNnPY6TG?6GE6fHBzdPCICKillhOyO3yfMwX 23-2-0 t-0 0 4-0-11 9-7-13 15-2 0 20-8-0_ 21 4 26.3-5 30-4-0 31-4-C 1-3-0 4-0-11 5-7.1 5 6 3 5 6-0 f) 4 - 3-1-5 t 4 0 11 1-0-* 2.1-12 Scale - 157.6 44 5x10 .70 21 20 is - 1$ I' 16 I5 NOP2XSTP= ht#'-fttb$Tf1Y 3x4 = 3x4 ' ' 800 WB - 4x8 = 4x6 = 3x4 4-0-11 4-9-13 9-7-13 15 2.0 20-8-0 26-3-5 r 4-0-11 �-9-2 4-10-0 5-6-3 I 5-6-0 5-7-4 Plate Offsets (X,Y)-- [2:0.5.0 0-1-12]. [2-0-8-10,Edge], [4:0-4-12,Edge], [8:0-5-0,0 2 8], [11:0-5-0,0-1-0] LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) -0A8 18-20 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.45 Vert(CT) -0.36 16 >978 '180 BCLL 0.0 ' Rep Stress Incr NO WB 0.48 Horz(CT) 0.07 13 Na n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T5: 2x4 SP 225OF 1.9E BOT CHORD 2x6 SP DSS WEBS 2x4 SP No-3 OTHERS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-5 cc purlins. BOT CHORD Rigid ceiling directly applied or 7-10-5 oc bracing. WEBS 1 Row at midpt 6-18 JOINTS 1 Brace at Jt(s): 8, 10, 6 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1700/0-8-0 13 = 1398/0-8-0 Max Harz 2 = .154(LC 6) Max Uplift 2 = -600(LC 8) 13 = -501(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-35=-4071 /1286. 3-35=-3963/1274, 3-4=-3943/1271, 4.5=-24941881, Continued on page 2 TOPCHORD 2-35=-4071/1286,3-35=-3963/1274, 3-4=-3943/1271, 4-5=-24941881, 5-7=-20671671, 7-9=-2003/670, 9-11=-2002/627,11-12=-2647/931, 12-13=-2905/913,4-6=-1598/466, 6-8= 5121198 BOT CHORD 2.33=-1137/3766,21.33=-1137/3766, 20-21 =- 1142/3743, 20-34=-1150/3871, 19-34=-1150/3871, 18-19=-1150/3871, 17-18=-74112464, 16-17=-74112464,15-16=-768/2604, 13-15=-768/2604 WEBS 8-11=-6491361, 5-8=-456,:299, 12-15=0/334, 6-20=-1141451, 8-18=-1271979, 6-18=-1641+423, 7-8=-336/1226, 4-20=-53/369 NOTES- (15) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511; B=45ft; L=281t; save=411; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPi 1. 04wk" -8) 30-4-0 4-011 PLATES GRIP MT20 244.190 Weight: 237 lb FT = 200% 4) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 5) Provide adequate drainage to prevent water ponding. 6) Alt plates are MT20 plates unless otherwise indicated. 7) All plates are 2x4 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 w,de will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 600 lb uplift at joint 2 and 501 lb uplift at joint 13. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 120 lb down and 39 lb up at 4-0-6 on top chord, and 50 lb down and 16 lb up at 4-0-0, and 451 lb down and 148 lb up at 11-8-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 14) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238172 34296-4-5 T24 COMMON TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print- 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:25 2021 Page 2 ID.JbsSUYEphcZuYTshvwE3BRyhOBX-iXxrlENz85XPjc ftzlLCVjBNpYyxnzRXK7VxVyfMW W NOTES- (15) 15) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building 's the responsibility of the building designer per ANSI TPI 1 as referenced by the building code-" LOAD CASE(S) Standard 1) Dead + Root Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 2-33=-20, 33-34=-38(F= 18), 13-34=-20, 1-4=-54, 4-7=-54, 7-14= 54 Concentrated Loads (lb) Vert: 33=-50(F) 34=-451(F) 35=-120(F; SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply 34296-4-5 T25 COMMON TR 3 1 A0238173 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:26 2021 Page 1 ID:JbsSUYEphuZuYTshvwE3BRyhOBx-AIVEVaibvPnLm00EgGaliGKzCmYgHsbm t2Tyyf AWV -1-0- 7-10-14 15-2-0 22-5-2 30-4-0 31-4-10 1-0 7-10-114 7-3-2 7-3-2 7-10-14 1.0-0 Scale n 1 53,9 5.00 12 4x6 = 0-8 06-4.8) SM = SX9 0.83005.8) 10-5-8 19-10-8 30-4-0 10-5-8 9 5-0 10-5-8 Plate Offsets KY) - [10:0 4 0.0 3.4j. [11.0 4 0 0 3-4j LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (ioc) Ildefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Vert(LL) -0.25 10-11 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 1.00 Vert(CT) -0.49 8-10 >720 180 BCLL 0.0 Rep Stress Incr YES W B 0.31 Horz(CT) 0.07 8 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 132 lb FT = 20% LUMBER - TOP CHORD 2x4 SIP No.2 BOT CHORD 2x4 SIP 225OF 1.9E 'Except' B2: 2x4 SIP No.2 WEBS 2x4 SIP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 1-4-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1170/0-8-0 8 - 1170/0-8-0 Max Horz 2 = -162(LC 10) Max Uplift 2 = -427(LC 12) 8 = -427(LC 12) Max Grav 2 = 1299(LC 17) 8 = 1299(LC 18) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-12=-2369/816, 3-12=-2331/835, 3-4=-2147/759, 4-13=-20761769, 5-13=-2073/780, 5-14=-2073/780, 6-14=-2076/769, 6-7=-21471759, TOP CHORD 2-12=-2369/816, 3-12=-2331/835, 3-4=-2147/759, 4-13=-20761169, 5-13=-2073/780, 5-14=-2073/780, 6-14=-2076/769, 6-7=-2147/759, 7-15=-2331/835, 8-15=-2370/816 BOT CHORD 2-11=-675/2244, 11-16=-358/1460, 16-17=-358/1460, 10-17=-358/1460. 8-10=-680/2123 WEBS 5-10=-2251890, 7-10=-416/299, 5-11=-225/890, 3-11=-4161299 NOTES- (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vul1=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0 , Interior(1) 2-0-0 to 15-2-0, Exterior;2R) 15.2-0 to 18-2-0, Interior(1) 18-2-0 to 31-4-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project eng near responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 427 lb uplift at joint 2 and 427 lb uplift at joint 8. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238174 34296-4-5 T26 COMMON TR 3 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Pr nt: 8.420 s Feb 10 2021 MiTek Indusir es, Inc. Thu Sep 9 13:35:27 2021 Page 1 D.JbsSUYEphcZuYTshvwE3BRyhOBx-ev3gwlDgin7zw?aoOnpHwpV6c6kPk3k ecc?OytMwU 7-10-14 15-2-0 22-5-2 30-4-0 31-44) 7-10-14 7-3-2 7-3-2 7 1014 1-0-0 Scale = 1:53.7 UY1X J I V = 0-6-6?0=1-8) 5.00 12 4x6 = 4 3x6 % 12 2 13 3x6 2x4 3 2 6 11 J\ �ti42 W2\ 10 is 16 9 54 `.016 = 14 4OP2X STP= 0-0-00=1-8) 10-5-8 19-10-8 30-4-0 F 10-5-8 9-5-0 10-5-8 Plate Offsets (X,Y)-- [9:0-4-0,0-3-4],[10:0-4-0,0-3-4] I LOADING (psf) SPACING- 2.0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1,25 TC 0.76 Vert(LL;- -0.25 9-10 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 1.00 Vert(CT) -0.51 1-10 >695 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.32 Horz(CT) 0.07 7 n/a n/a BCDL 10.0 Code FBC20201TPl2Oi4 Matrix-SH Weight: 131 lb FT = 200% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP 225OF 1.9E `Except' B2: 2x4 SP No,2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 1-4-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 1096/0-8-0 7 = 117110-8-0 Max Horz 1 = -160(LC 10) Max Uplift 1 = -357(LC 12) 7 = -428(LC 12) Max Grav 1 = 1236(LC 17) 7 = 1300(LC 18) FORCES. (lb) Max. Comp,/Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 1 -11� 23791841, 2-11=-23401856, 2-3=-2155/780, 3-12=-2083/791, 4-12=-2081/802,4-13=-2076/786, 5-13=-2079/776, 5.6=-2150/765, TOP CHORD 1 11=-23791841, 2-11=-2340/856, 2-3=-21551780,3.12=-2083/791, 4-12=-2081/802, 4-13=-2076f786, 5 13=-20791776, 5-6=-2150/765, 6-14=-23331843, 7.14=-2371/824 BOT CHORD 1 -1 0=-681/2254,10-15=-366/1463, IS- 16= 366/1463, 9.16=-366/1463, 7-9=-68712126 WEBS 4-9=-223/890, 6-9=-416/300, 4-10=-229/89812-10=-421/301 NOTES (8) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl„ GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 3-4.0, nterior(1) 3-4-0 to 15-2-0, Exterior(2R) 15-2-0 to 18-2-0, Inierior(1) 18-2-0 to 31-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, wish BCDL = I O.Opsf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 357 lb uplift at joint 1 and 428 lb uplift at joint 7. 8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Qty Ply A0238175 34296-4-5 Vol VALLEY TR 2 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Pr nt: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:28 2021 Page 1 ID:JbsSUYEphe2uYTshvwE3BRyhOBX-65d_wGJrROv a4amL512g7LoHofF8FFu41M9xgyfmwr r 4-6-3 4-6-3 Scale = 1:11.2 S 2x4 2x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.28 Vert(LL) n/a nla 999 TCDL 7.0 Lumber DOL 1.25 BC 0.15 Vert(CT) n.+a nla 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 nla nla i BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-6-3 oc purlins, except end verticals. SOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS, (lb/size) 1 = 134/4-5-9 3 = 134/4-5-9 Max Horz 1 = 59(LC 12) Max Uplift 1 = -31(LC 12) 3 = -56(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C. Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 4-4-7 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live'oad shown covers rain loading requirements spec;fic to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in a I areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection .:by others; of truss to bearing plate capable of withstanding 31 lb uplift at joint 1 and 56 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard PLATES GRIP MT20 244,190 Weight. 15 lb FT = 20% SALVADOR JURADO R.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238176 34296-4-5 V02 VALLEY TR 2 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:29 2021 Page 1 ID:JbsSUYEphcZuYTshvwE3BRyhOBX•blAMScKTCK2rCE9zvppHMLuotQ1 UOV1 Sy%4HyfMW `s 2-6-3 2-6-3 SCa'B 1 :7.4 2 2z4 2-5-9(0-1-8) Fxa 2-5-9(0-1.8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (lac) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.05 Vert(LL) n/a n/a 999 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(CT) nla n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-6-3 oc purlins, except end verticals. SOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 60/2-5-9 3 = 60/2-5-9 Max Horz 1 26(LC 12) Max Uplift 1 = -14(LC 12) 3 = -25(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES. (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 14 lb uplift at joint 1 and 25 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard PLATES GRIP MT20 244.190 Weight: 7 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oty Ply A0238177 34296-4-5 V03 VALLEY TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:30 2021 Page 1 ID �JbsSUYEphcZuYTshvwE38RyhOBX-3UkkLyL5zdAicIQ9TWK WvYR5ogJzc9lBgcrGcjyfM WR _ 5-0-0 5-0-0 2x4 2x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefi Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.37 Vert{LL) ma nr'a 999 TCDL 70 Lumber DOL 1.25 BC 0.20 Vert;CT) n,:a nia 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz;CT) 0.00 n/a n/a BCDL 10.0 Code FBC20201TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. _ REACTIONS. (lb/size) 1 = 15214-11-6 3 = 15214-11-6 Max Horz 1 = 66(LC 12) Max Uplift 1 -36(LC 12) 3 = .64(LC 12) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Wind: ASCE 7-16; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511; B=45tt; L=28ft; save=4ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(i) 3-9-1 to 4-10-4 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer Project engineer responsible for verifying applied roof live load shown covers rain loading requ-rements spec fic to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurreni with any other live loads. 5) ' This truss has been designed for a I ve load of 20.Opst on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 36 lb uplift at joint 1 and 64 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TIP 1 as referenced by the building code." LOAD CASE(S) Standard Scale: 1 "m V PLATES GRIP MT20 244/190 Weight:16 b FT 20°� SALVADOR JURADO P.E STATE OF FLORIDA RES NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 Job Truss Truss Type Oly Ply A0238178 34296-4-5 VO4 VALLEY TR 1 1 Job Reference (optional) Run: 8.420 s Feb 10 2021 Print: 8.420 s Feb 10 2021 MiTek Industries, Inc. Thu Sep 9 13:35:30 2021 Page 1 ID'JbsSUYEphcZuYTshvwE3BRyhOBX-3UkkLyLszdPugOj9T W KWvYR9ggMOc916gcrGciyiMW R 3-0-0 3-0-0 2x4 2x4 2-11-6(0-1-8) 2.11.6(0-1-8) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) n/a nla 999 TCDL 7.0 Lumber DOL 1.25 BC 0.05 Vert(CT) n/a nla 999 BCLL 0.0 " Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC2020'TP'2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No,2 BOT CHORD 2x4 SP Na.2 WEBS 2x4 SP No 2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3 0 0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, In accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 781,2-11-6 3 = 78,'2 11-6 Max Horz 1 N 341LC 12) Max Up ift 1 = -18(LC 12) 3 -33(LC 12) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 11 Wind: ASCE 7-16; Vuh 165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L 28h; eave=4ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL■1,60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 18 lb uplift at joint 1 and 33 lb uplift at joint 3. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." LOAD CASE(S) Standard Scale = 1:8.3 PLATES GRIP MT20 244/190 We-ght:9 lb FT = 20% SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MIAMI FL. 33166 . ' Th s sty alert symboluse to attract your A attentlonl PERSONAL SAFETY ISINVOLVEDI When you ese this symbol - BECOME ALERT - HEED ITS MESSAGE. 14ACAUTION: A CAUTION Identifies safe operating practices or Indicates unsafe conditions that could result In personal Injury or damage to structures. HIB-91 Summary Sheet COMMENTARY and RECOMMENDATIONS for HANDLING, INSTALLING & BRACING METAL PLATE CONNECTED WOOD TRUSSES° It Is Me reg2 aslbllltyr of fhe Instapsr lbuNder, bulldlrtt7 contractor, licensed r ffecdon contractor to PMPGFIV race".unload stain handle. inabadland brace metaiolafe connected wood trusses to amtect Na and gMeerbLTheinsteller must exerelse the same high degree of safely awareness as with any other structural material. TPI does not intend these recommendations to beirdetpretedas euperlwtothepro]ectArchitect's or Engineer a design specification for handling, Installing and bracing wood trussesfor a particular roof orfloor. These recornmendatlons are based upon the collective experience of leading technical CAUTION: The builder, building contractor, licensed contractor, erector or erection contractor Is ad- vised to obtain and read the entire booklet "Com- mentary and Recommendations for Handling, In- stalling a Bracing Metal Plate Connected Wood Trusses, HIB-91' from the Truss Plate Institute. DANGER: A DANGER designates a condition Awhere falluretotollowInstructions orhood warn. Ing will moat likely resit to serious personal Injury or death or damage to structures. WARNING: A WARNING describes a condition I A where fallureto follow Instructions could result in TRUSS PLATE INSTITUTE tfe3 D•Ortvkio Dr., Suite 200 Madison, Wisconelri 53719 (e08) 9334900 personnel Inthe wood truss Industry. but mustdueto the nature of responsibilities Invoived, be presented as a guide forthe use of a qualified building designer or Inslaller. Thus, theTruss Plate Inelitute. Inc. expressly diselalms any responsibility fordamages stioing from theuse.*Mcadonorrelance ontherecommendations and Information contained herein by building designers, insulters, and others. Copyright O by Tnma Plata institute. Inc. All rights reserved. This deoument or any part thereof must not be reproduced In any form without written permission of the publisher. Printed in the United Slates of America. UAu tfUN: AfftenlpOrary Draoing should bdno Ives ,than2x4 grade marked lumber. All connections should be made with minimum of 2-1sd nails. All trusses assumed 2' on -center or less. All multi -ply trusses should be connected together In accor- dance with design drawings prior to Installation. TRUSS STORAGE - CAUTION: Trusses should not Abe unloaded on rough terrain or uneven surfaces which could cause damage to the truss. Trusseesstored horlmntally should be sup- ported on blocking to prevent excessive lateral bending and lessen moisture gain. WARNING: Do not break banding until Installa- tion begins or Iift bundled trusses by the bands. [A:: WARNING: Do not use damaged trusses. Trusses stored vertically should be braced to prevent toppling or tipping. DANGER: Do not store bundles upright unless properly braced. ADANDER: Walking on trusses which are lying flat Is extremely dangerous and should bestric ly prohlbited. Frame 1 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 Tay WARNING: Do not attach cables, chains, or WARNING: Do not lift singletrusseswith spans hooks to the web memberc greater than 30' by the peak. MECHANICAL /Omx IINSTAU ATION Approldmately Approximately Tay=- _~ %trues length %lrusa length Line - - Truss spans loss then 3W. Lilting devices should be connected Slrongback/ Spreader Bar to the truss top chord with a closed- Spreaderftr loop attachment utilising materials to• Toe to Toe In such as olings, chains, cables, nylon strapping, etc. of sufficient strength to carry the weight of the truss. I Approximately Approximately Less than or equal to Bo' ` Tag Una Spreader Bar Toe In --\ /—Toe In ApproxlmMly Tag Une At or aborri mid•helgM Less than or equal 10 60' une TLUM Greater than W CAUTION: Temporary bracing shown In this summary sheet Is adequate for the Installation a4 Atrusses with similar configurations. Consult a regisiered professional engineer d a dMerent bracing arrangement Is desired. The engineer may design bracing in accordance with TPI's Rec9ainvended Design SpeaNkmdon for Temporary Bracing of Metal Plate Connected Wood Trusses; DS849, and M some cases determine that a wider spacing Is possible. GROUND BRACING: BUILDING INTERIOR jdROLJNb BRACING: BUILDING EXTERIOR TOP err TO" wAk+N 8004 nl PIwFi.iWar i F e d' > 1@taaw Drlwa woww .uw.... CAUTION: Ground bracing required for all installations. TvP'0d h-W"" W WM"WWM rrld 1P104ftk . a1q r�sii Wan wpdt" M (W Frame 2 SALVADOR .IURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 'a' Topetwrdwadwe kftrolyIrraede tw We t*Vmw wwssoeeooeepeeettwnlenodleeo- nNNreWo 01* a broWna4w"wnw.+ lathe uedereldesrtrrteoelordwseaaur{Irmo we aft*" togo Icpwa elvw Imo sherd It 1 4 or Omelet r 7i T' 1 'r �,V TOP Ci Z TOP�AOb b LIRACH itMi mum p, LA U 'ACE � �� $Md- d (09 SPA Cif- SPACIiII � tr'usletis G• i I. 'il l over 3Y - 4! 4 0' 7 Over 4B' ' 60' EE 2 b' Over 60' Sea a re•phlered professional nlylneer OF -- 8PF -- SpPhFir All lateral braces lapped at least 2 trusses. Continuoue Top Chord Literal &ace Required 1W or Greater Attachment Required WARNING: Fellurstotollowthesereoonsmondattonecould result In setters pera mall Injury or damage to uussea or buildings. PITCHED TRuss TOP C(tORD MINIMUM TOP CHORD DIAGONALBRACE Pack LATERAL BRACE spACING (D 12 SPAN DIFFERENCESPACINO(LBS) $ J►trrtss. - - s r— me to 26' 1 Over 28' - 42' 3.0 6' 9 6 Over 2' - W 3.0 S S 3 Over so' See a registered professional engineer OF: Douglas Fir -Larch SP - Southern Pine MirHen►-Fir 8PP- Spruce-PlwFir Continuow Top Chord Lateral Brace All lateral braces Required lapped at least 2 trusses. 10" yr Greater 4 Attachmerrt • y = Required 0. \ tY �r ; _. - _ t_ �•� ��� TprdradatlNsnlstareeybaadesn4rrolN �ti :.. toeaB.reade.w.oaueO.arewrelwdieeo- . �- ` _ 1. �, y� nrer ppaww+aneeueuwaneuw At ry 10OW' n-11 QFNwtoechadwheaow1WA ems Mteehed to eN balls of On toy clad SCISSOR$ TR�lS8 Frame 3 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. IMAAIMI: FL. 33166 IMs 4 or greater Bottom chord diagonal bracing repeated ` at each end of the building and at same spacing as top chord diagonal bracing. SPAN MINIMUM PITCH BOTTOM CHORD 'LATERAL BRACE SPACING(LBW BOTTOU CHORD DIAGONAL BRACE SPACING (D IaI►trrteaer< Up 10 32' 4112 1 g' 20 15 0V0r 22' - 48' 4 12 13' 10 7 Over 49' - 90' 4 12 I is, s e Over 60' See a f ieiered ratesalonal ea Inner WF - H�enraFlr mr-Larcn SPPF southern PGre SPnwe-Pine-Fir All lateral braces tapped at 1008112 trusses. BOTTOM CHORD PIANE WARNING: Failure to follow thesarecommandatlonscouIdreeultIn E: severe personal injury or damage to trusses or buildings. A Permanent continuous �. lateral bracing as specified by the - truss engineering. WEB MEMBER PLANE Cross bracing repeated at each end of the building and at 20' Intervals. Frame 4 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 640 74 AVE. MAIMI FL. 33166 SPAN MINIMUM DEPTH TOP CHORD LATERAL BRACE SPACING(LBs) TOP CHORD DIAGONALBRACE SPACING (OBE t#o u"Oes SPIDF iPFJNF U to 32' 3V 8' 18 10 OW 32' - 48, 4r e' 8 Over 48' • i.41r 1 8'1 4 2 Over ow Sae a registered professional vVinser DF - Douglas F1r•Larch SP - Southern Pine HF - Ran%-FIr SPF - Spruce -Pine -Fir d - [2fx412Nx16 PARALLEL ORD TRUSS Topchorda Dwtare lahranr iraead oarr bueMtr teea8taeand oasateollapaa 1f tMan la no dlatia adbradro Diaeonatbraolneahouldbeneow to the who"" of ato lap ehardwbae purlieu m et %W so the sopeld* N the top *herd. Continuous Top Chord LateralBrac Requir e Regarir ed 1tYofareate r Attachment Required roh+r 20yassJ 3W or greater brawk lapod it IrttYVo The end trusser. diagonal brace for cantilevered End diagonals ari iaeemkiior trusses must be stability and must be dupilci&W on placed on vertical both ends of the truss system. rebe In line with the eupporc . AWARNING: Failure to follow the" recommendations could result In Severe Personal Injury or damage to trusses or bulldings. A& 4X2 PARALLEL CHORD TRUSS -TOP CHORD Corttinuoue Top Chord --\ Top cherdaawtareMstrlraerbraoadcan bwkla Lateral &eCe t°put!'aandoauaeoollap'aplbanau"°°ipp Required 1 nalbraeft. DaaranarWWi"altouubana0e0 loth' u,&r"&ee tk-'°peh"rd"I guar"* ur or Greater are eaaohad tvele Iopaldaol lla lop a ItorrR AuachmsM 16 Required is r 300 roSs1 31/a Truss" muethavelurn- bar oriented in the hort- Itlit zornal direction to use breoel! I - wn We brace a oin aPAed � pe g. at least i+rlo � - x. End diagonals sr! f l lisetrrilMl.for stability and must be dupl`:Hl on both ends of the truss system. Frame 5 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 SPAN MINIMUM PITCH TOP CHORD LATERAL BRACE SPACING(LHg) TOP CHORD DIAGONAL BRACE SPACING (DOS) I# truas"I Up to 24' 3/12 S. 1 T 1 12 Over 24' - 42' 3112 7' 10 1 6 Over 42' - 54' S 12 $ DF- Douglas Fir -Larch HF - Hem -Fir ' s a SPSSpruc�s Pins F- PirwFir Diagonal brace also required on end verticals. Tap chordm UW*rn latarity broeod an bu" 4900"W41W a"uwaeaap"Nume lawrrdlaer rwbr&&4 Diago"IbradnyahouldbomM d b IM undarakaot 1tN bD Oherd when purlme era dtadnd 10 dw topNOu of Ow top abord. MONO TRUSS PLUM 12 � gor rWer s• 4 s• ii All lateral braces lapped at least 2 trusses. Continuous Top chord Lateral Brace - Requlred 10' or Greater Attachment Required WARNING: Failure to follow these recommendations could result In severe personal Injury or damage to truaees or buildings. A I I Truss I Depth 1 I Dos) I 1 Lesser of Ir D/60 or 2' IMaxlmunt Plumb Misplacemsm Line INSTALLATION TOLERANCES so �th Lon) 1 4' 1' Lesser of Ll200 or 2- Don} 12" r 38" 3 4" 3' so" 1.1 4" S' 72" 1-1 8' " 1- r Sep f e' 1 o8" r T Lon) Lon) L=0 L(ft) so*11 ' 1 W 3/4- 12.6' Lon) ' Lessor of L/200 or 2" L(In) L1200 L(ft) 20(r' 1- 16.71 2ti(" 1.1 4• 20.8' 300" 14/2" 25.0' OUT -OF -PLUMS INSTALLATION TOLERANCES. OUT -OF -PLANE INSTALLATION TOLERANCES. DANGER:: Under no circumstances should JAWARNING: Do not cut trusses. construction load* of anydeacriptionbepfaced IlAon unbraced trusses. Frame 6 SALVADOR JURADO P.E STATE OF FLORIDA REG NO. 19939 - 6401 NW 74 AVE. MAIMI FL. 33166 PLATES ARE MITEK M20-249,200 MANUFACTURED FROM ASTM A 466 GRD A GALVANIZED STEEL (EXCEPT AS PLATE MUST BE INSTALLED ON EA. FACE OF JOINT SYMMETRICAL (EXCEPT AS SHOWN) DESIGN CONFORMS WI NDS SPECS. FBC2020.THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS READ.) CONSULT BLDG. ARCHITECT. OVERHANG DETAILS MAXIMUN OVERHANG GRADE OF LUMBE I 2X4 2X6 # 2 SO.PINE 2'-0" 3'-2" S.S. SO -PINE 2'-2" 3'-4" NOTES: OPTIONAL VERTI A) ALL CONNECTORS SPEC. MUST BE INSTALLED PER MFG. SPECIFICATIONS. C) FOR TRUSS DATA,LUMBER,PLATES, ETC. REFER TO INDIVIDUAL ENG. DRAWINGS. D) THIS HAS BEEN DESIGNED FOR THE LOADS GENERATED BY 175 MPH. WINDS AT 26' ABOVE GROUND LEVEL ASCE 7-16 COMPONENTS AND CLADDING AND 7.0 PSF TOP CHORD AND 3.0 PSF B, CHORD DEAD LOAD ARE BEING USED.THE DESIGN ASSUMES OCCUPANCY CATEGORY II, TERRAIN EXPOSURE C AND INTERNAL PRESSURE COEFFICI CONDITION I. 2X4 OR MAX. 1'-6" WIOUT LEDGER P'ER AND HANGER (BY BLDR.) A. MAX. 4'-6" 4 s 2 APPRO f COMBgS �O.1JC. DES. BY �� M oAOE rRuss = CHECKED BY-;— Company Inc. * v DATE • 01101/21 6401 N.W. 74 AVE MIAMI, FLA. 33168 !+ 2 DADE {306} 6924245 BROWARD (305) 462MU � � �A� �F •* l � a~ DRAWING MM WATW 14M.M.7842 FAX: (306) 4T743= p`T �'i JOB No. 7ah,, ANAL7 ti+ ��ierrrrlr111�N1N���� Minimun Grade Of Lumber PLATES ARE MITEK M20-249,200 MANUFACTURED FROM ASTM A 466 GRD A GALVANIZED STEEL (EXCEPT AS SHOWN) 2X4 Syp. No. 2SP PLATE MUST BE INSTALLED ON EA. FACE OF JOINT SYMMETRICALLY (EXCEPT AS SHOWN) DESIGN CONFORMS W/NDS SPECS, FBC 2020 THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS REGO.) CONSULT BLDG, ARCHITEC INDICATES DEAD LOAD ON U i 8# 601 —' R 92-- tau 1 ,42' .25' oa' O 12 A) ALL CONNECTORS SPEC. MUST BE INSTALLED PER MFG. SPECIFICATIONS. B) HANGERS REQ'D FOR TRUSSES LESS THAN 12'-0•' SPAN (UNDER 650# (REACTIONS) MUST BE SUPPLIED BY BLDR. C) FOR TRUSS DATA, LUMBER, PLATES, ETC. REFER TO INDIVIDUAL ENG. DRAWINGS3. D) THIS HIP SET HAS BEEN DESIGNED FOR THE LOADS GENERATED BY 146 MPH WINDS AT 25 FT. ABOVE GROUND LEVELASCE 7-16 COMPONENTS AND CLADDINCG AND 7.0 PS TOP CHORD AND 3.0 PSF BOTT. CHORD DEAD LOAD ARE 8EING USED. THE DESIGN ASSUMES OCCUPANCY CATEGORY II, TERRAIN EXPOSURE C AND INTERNAL PRESSURE COEFFICIENT CONDITION 1. TO 303 THROUGH JO7) '-0" TO 7'-0" PA1 USP ANGLE (OR EQUAL) AND -16d TOE NAILS (BY BLDR.) 0. 01-0417-11 tMAX. REACTION 395# 16d TOE NAILS] q�11% 2-16d TOE NAILS _ •i `' V LOADING. PS APPRO'I E TRIES CD. INC-- BY ; MM TOP WE 30 r$IECKED BY : � TOP DEAD : 15 JACK DETAIL (7'-Q" SETBACK) Hang TRUSS STATE OF ; t TT: 0�10121 BOAON 10 6101 ILA- 74 A` R YIAW. 1A. S11 .���i�`'•;�1ORID� .•'r��� RAWING - -- u,oc w� G,aer1 te n.: • ... •:.1,C)� _.,- JO8 No. Minimun Grade Of Lumber PLATES ARE MIIEY, M20-249,200 MANUFACTURE) FROM ASTM A 466 GRID 4 GALVANIZED STEEL (EXCEPT AS SHOWN) 2X.4 Syp. No. 2 SP PL4"E MUST BE INSTALLED ON EA FACE OF JOINT SYMMETRICALLY (EXCEL'' AS SHOWN) DESIGN CONFORMS WADS SPECS. FBC 2020 THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS REOD.) CONSULT BLDG. ARCI ITEC I IC, C USF 1" 20G CALVE. METAL STRAP NAILED W/2-10d NAILS ON EA. MEUBER, PER FACE, OR 2 HURRICANE Cl IPS. ONE ON E.A. FACE OF TRUSS. (BY BLDR.) TYP, VALLEY SET CONNECTION DETAI PITCH VARIES 6' WEDGE NAILED TO TRUSS W/2-1Gd NAILS. (BY BLDR.) TYP. ae,52�!� 0400 DADE TRUSS cam., 6401 N V 74 AVE- MIAMI. PTA 33166 DA 130) %2-824S IIRIYMR 0%) %- curs: ,-sae-YA-7842 W: 0014 AM qr. VERTICALS 9 6'-0" O C Vd X. OVER 24'-Q" 20-0' AND OVER VAL E 2' MAS-151DI TRUSS SYMMETRICAL ABOUT CENTER LINE EXCEPT AS SHCOWN SPL. 00F C F �o I'oR rI 1 3 S6. 'INC. S STATE OF �.aa ONAL ��.a�``;� y 2X4 WI LEY CATS (EY SLRR.) IRUSS Es. By NIM jH;:CKED BY SJ FATE _ 01101121 "RAWING JOB No. Minimun Grade Of Lumber 2X4 Syp. No. 2 SP PLATES ARE MITEK M20-249,200 MANUFACTURED FROM ASTM A 466 GRD A GALVANIZED STEEL (EXCEPT AS SHOWN) PLATE MUST BE INSTALLED ON EA. FACE OF JOINT SYMMETRICALLY (EXCEPT AS SHOWN) DESIGN CONFORMS W/NDS SPECS, FBC 2020 THIS DESIGN IS FOR TRUSS FABRICATION ONLY. FOR PERMANENT BRACING (WHICH IS ALWAYS READ.) CONSULT BLDG. ARCHITEC iZLC BC CONNECTED TO A FIXED RICIO PONT OR X-BRACED AS NOTED ON THIS DETAIL. lIN a 213 LATERAL BRACE PER TRUSS DESIGN TOTH 2-104 NAILS PER WES FOR FORCES UP TG 4600 lws- FORCES IN EXCESS OF 4600 Ibs RE009MS 2116 /J OR BETTER. NOTE PROVIDE X-BRACING AT 29Y-O' INTERVAL$ FOR wE6 FORCES UP TO 2M III& AND AT 10'-0' FOR FORCE GREATER THAN 2309 Ibc 'cFT'Ihr'-zw4) LATERAL BRACING DETAIL ALT. LATERAL BRACING DETAIL toe o a' j�—O.C. TlP rt TRUSSES O 24'lrT-BRACE SAG( SIZE O.N: LtP AND GRADE AS We T-BRACE KITH WEB (24 µAx; IOd NAYS O a' O.C. TYP. WEB SECTION DETAIL NOTE; BRACE LNTST BE 809 THE LENGTH OF THE WES. THIS DETAIL IS 70 BE USED AS AN ALTERNATE FOR CONTINUOUS LATERAL BRACE4. LATERAL BRACING DETAIL 4ADcmem ,ass Wl 11A. 74 ATE. 1Q1fQ. 1Ll 33166 s10E Ross W-M WIMM Rob) 40-IM 1:ATI5 1-900-3e-M2 Fix pQ 4n-M E FOR DADVRUSS,Co:• III. STATE G)P ,q D . BY MM C CKED BY SJ D 1 : OvOvu DRAWING JOB No. Hanger Index HangerOptionsMatrix................... ...... ............. 98-99 Solid Sawn Joist Hangers • Face Mount ............................................. 100-119 • Sloped and Skewed ................................ 114-119 • Top Flange ............................................... 122-134 • Specialty ........................................... 120,136-137 Fire Wall Hangers ......................................... 229--233 Hanger Load Table Explanation ' ' This icon identifies products approved for installation with Simpson Strong -Tie Strong -Drive SD Connector screw. See pp. 335-337 for more information. Gauge: Min./Max.: Refers to min. or max, nailing for products with round and triangle holes. Min. nailing uses round holes. and max, nailing uses round and triangle holes to achieve maximum load. I Joist Size: Model No.: Product Nails: This shows This shows This is the material the fastener the size of Simpson thickness. quantity and type joist member. Strong -Tie required to product name. achieve the table loads. v i SIMPSON Strong. -Tie I -Joist, Glulam and Structural Composite Lumber Connectors • Face Mount ............................................. 139-150 • Adjustab e........................................................ 151 • Sloped and Skewed ................................ 152-155 • Top Flange ............................................. 159-183 Plated Truss Connectors .............................. 186-228 Masonry and Concrete Connectors ............. 234-259 Load Duration: Installed Cost Index: Assumed duration factor used This indicates the to determine the allowable load. products relative installed cost (combined cost and Allowable Design Loads: The inslallatK,n cost). maximum load that a-..:cti,� is designed to provide Uplift Floor, Snow, Roof, Da I A_`� Dimensions (in.} Faste rs (in.) DF/SP Allowable Loads installed Joist Model Ca' MinJ Cost Index Code Size Na. Max. Header Joist UpliftTF,17oorinow Roof (ICI) Ref. (160}115) (i25) Sawn Lumber Sizes LUS26-2 18 31 s 4'/4 2 -4' 0162 x 31/2 (410.162 x 311 1,060 1.030 1,170 1.265 Laresl U26-2 16 31/8 5 2 (8 0,162 x 31/2 (4) 0.148 x 11/2 535 1.150 1.305 1.410 +65% 2X6 HUS26-2 14 31s 5416 2 I — 14) 0162 x 3'h (4) 0.162 x 3'1h 1.165 11055 1.195 1.290 +172% IBC, L LA 14 314 53A 2'k Min 18) 0162 x 31,, (4) 0148 x 1'k 755 1190 1.345 1.440 +233% HU26.21HUC26-2 14 I 1 s 5Vs 1 2'h Max 112) 0.162 x 3,5 (6) 0148 x i '1h 1 135 1185 2,015 2,165 +254% This icon identifies products that are available with additional corrosion protection. See p.12 for additional information. 94 \V Dimensions W, H, B: This shows the product dimensions (width, height and bearing length in this case.) referenced in the product drawrin g. Nails: 0.162" x 31/2", 0.148- x 1 %2". Code Ref.: See pp. 21-22 for other nail sizes aril information. See p.12 for the Code Reference Throughout this catalog, the table Key Chart, to fastener size indicates the required nail determine wh'ch diameter and length. See pp. 21-22 for code reports load adjustment factors for alternative include this fasteners used with some connectors. product All installations should be designed only in accordance with the allowable load values set forth in this catalog. Product Drawing: Provides a graphic presentation of the product with dimensional information (often cross referenced to the table). LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers This product is preferable to similar connectors because W of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. T ho r1QLA Q sheer hangf,' :i4'ms, ranging frotn the light Capacity LUS halige:s to the highost•capa:itvd Hf SUS hangers, feitt,re innovative double shear nailing that distriE utes the load through Nvo points on each joist nail for greatL3r Strength, This allows for fewer nails, faster installation and the use of all common nails for the same connection. For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel or ZMAX" coating. See Corrosion Information, pp. 13-15. Installation: • Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. • Not designed for welded or nailer applications. Options: • LUS and MUS hangers cannot be modified • Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Cedes: See p.12 for Code Reference Key Chart 6 Double -Shear Nailing Top View Double -Shear Nailing Side View Do not bend tab Dome Double -Shear Nailing Side View (Available on some models) V 1or 2x's f Vk, for 4Xs e Z- I I} a C O e 0 HI C c � I s W . 8 LUS28 6 HHUS210-2 e�tr ol� � 6 6 ha. w G 4 c �• � � • gulri C g • G• 2 �`L 6MUS28 I • o i d .e OHUS210 ' (HUS26, HUS2$ and HHUS similar) T 0at_ B HGUS28-2 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) 12 a 0 "M93 4 IL 0 LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers (cont.) Model No. Min. Height Ga.Heel Dimensions (in,) Fasteners W H I g Carrying Member Carried Member Single 2x Sizes LUS24 2% 18 13is 3 %6 1 V. (4) 0.148 x 3 (210.148 x 3 LUS26 4h. 1%6 4VA 13/. (4)0.148x3 (410.148x3 MUS26 4'Ye 18 11t6 51tb 2 (6) 0.148x3 M 0148 x 3 HUS26 06 16 1 sib 5% 3 04) 0,162 x 3 �i (6) 0.162 x 3'h HGUS26 4Vs 12 1 % 5% 5 {20) 0.162 x 31h (8) 0.162 x 3'A LUS28 06 18 1 �16 6% 1 Y4 (6) 0.148 x 3 (4) 0.148 x 3 MUS28 13% 18 19A6 61,i6 2 (8) 0148 x 3 (8)0.148 x 3 HUS26 6Fk 16 1 % 7 3 12211l 0.162 x 31b (8) 0.162 x 31/z HGUS28 6% 12 1 % 71/e 5 (36) 0162 x 31h (12) 0162 x 31/2 LUS210 4+/4 18 1 i6 714'ie 1 ]4 (8) 0.148 x 3 (410.148 x 3 H US210 83'6 16 1 % 9 3 (30) 0.162 x 3'h (10) 0162 x 31k H' S210 8;,, 12 1 % 914 5 (46) 0.162 x 3'/k 1 (16) 0.162 x 3'k 1. See table below for allowable loads. SIMPSON Strong -Tie These products are available with additional corrosion protection For more information, see p.15, Q For stainless -steel fasteners, see p. 21. Many of these products are approved for installation Mwith SlroRg-Drivel SD Connector screws. See pp. 335-337 for more information. Mode! DF Allowable Loads Allowable Loads SPF/HF Allowable Loads Code No. Uplift (160) Floor (100) Snow. (115) Roof {125) Wind Uplift (164) (160)) EF1,11r Snow (115) Roof (125} Wind (160} Uplift (160) Floor Snow (100} 1(115) Roof (125) Wind (160) Ref. Single 2x Sizes LUS24 435 670 765 820 1.045 435 725 825 890 1,120 360 495 1 565 (305 770 LUS26 1,165 865 990 1,070 1.355 1.165 935 1,070 1,150 1.475 865 635 725 785 1,000 113C. FL, MUS26 930 1.295 1,480 1.560 -1,560 930 1,405 1,560 1,5G0 1,560 810 955 1,090 1,180 1,350 LA HUS26 1,320 2.735 3.095 3.235 3235 1,32.0 2.960 3.20.0 3,2.60 3.280 1,151) 2.350 2.660 2,780 2,760 HGUS26 875 4.340 4.850 5.170 5,390 875 4.690 5,220 5,390 5,390 180 3,225 3,610 3,810 3,985 113C. FL LUS28 1,165 1.100 1,260 1,350 1.725 1.165 1,195 1.360 1,465 1.730 865 810 925 1,000 1.270 MUS28 1.320 1.730 1,975 2,125 2,255 1.320 1,875 2,135 2,255 2,255 1.150 1,270 1,455 1,575 1,955 IBC, fL. LA HUS28 1.760 4.095 4.095 4.095 4.095 1.760 4,095 4.095 4.095 a i#95 1.380 3.520 3,520 3,520 3,520 HGUS28 1.650 7.275 7.275 7.275 7.275, 1,650 7,275 7.275 7,275 7,275 1,325 3.670 3,820 3.915 4.250 IBC. FL LUS210 1,165 1.335 1.530 1.640 2,090 1,165 1,450 1.655 1.775 2.270 865 985 1,120 1,215 1.500 18C, FL. HUS210 2,635 5,450 5,795 5.830 5.830 2.635 5,395 5.780 5.830 5.830 2.220 4,685 4,965 5.015 5,015 LA HGUS210 2,090 9.100 9.100 9.100 9100 2.090 9100 9.100 9.100 9.1a?0 1.145 6.340 6,730 5.730 6.730 1 19C. FL 1. For dmensions and fastener information. see table ab(ve. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp.98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers Can be skewed to a maximum of 45" and;'or Sloped to a maximum of 45' • For skew only, maximum allowable download is :).85 of the table load • For sloped only or sloped and skewed Clangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0 72 of the tattle load, not to exceed 2 4i'S lb. • The joist must be bevel -cut to allow for double shear na ng HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 45`. Allowable loads are HGUS Seat Width Joist Down Load Uplift W < 2" Square cut 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table bad 0.46 of table load 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square cut 0.46 of table load 0.41 of table load W > 6" Bevel cut 0.85 of table load 0.41 of table load Acute - side Specify angle Top View HHUS Hanger Skewed Right {foist must be bevel cut) All joist nails installed on the outside angle (non -acute side). 154 UPDATED 12/01/20 LUS/MUS/HUS/HHUS/HGUS These products are available with For stainless additional corrosion protection. ,ti steel fasteners. For more information, see p. 15, see p. 21. Many of these products are approved for installation ®1 with Strong -Drives SD Connector screws. See pp. 335-337 for more information, SIMPSON Strong. -Tie Model Min. Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads Heel Height Ga. W H g Carrying Member Carried Member Uplift (i60) Floor {100} Snow oof (115) 1('125) Wind (160) Uplift (160) Floor (100) Snow (115) Root (125) Wind (160) Code Ref. Double 2x Sizes LUS24-2 2Y, 18 1 3% 31'A 2 (4) 0.162 x 3'h (2) 0.162 x 35h 410 800 905 980 1.245 355 690 1 780 845 11,0701 LUS26.2 4s/6 18 3'/e 4'A 2 (4) 0.162 x 31h (4) 0.162 x 3'h 1.060 1,030 1,170 1,265 1,595 910 885 11,005 1,090 11.370 HHUS26-2 43i6 14 3?i6 5311 3 (14) 0.162 x 3 h (6) 0.162 x 31h 1.329 2.830 3.190 3.415 4.250 1,135 2,435 2,745 2.935 3,655 HGUS26-2 06 12 N6 5'/16 4 (20) 0.162 x 3112 (8) 0.162 x 31/2 2,155 4.340 4,850 5.170 5,575 1,855 3.730 4.170 4,445 4.795 LUS28.2 43i6 18 31/e 7 2 (6) 0.162 x 3'h (4) 0.162 x 3'h 1.060 1,315 1,490 1,610 2,030 910 1.130 1,280 1.385 1,745 IBC. FL, HHUS28-2 6% 14 3316 71/4 3 122) 0.162 x 31h (8) 0.162 x 31h 1,760 4,265 4,810 5.155 5.980 1.515 3.670 4.135 4,435 5,145 LA HGUS28-2 69A6 12 39i6 7346 4 (36) 0.162 x 31h (12) 0.162 x 31h 3,235 7,460 7,460 7,460 7.460 2,780 6,415 6.415 6.415 6,415 LUS210-2 06 18 31/e 9 2 (8) 0.162 x 3112 (6) 0.162 x 31h 1.445 1.830 2,075 2.245 2.830 1,245 1.575 1,785 1.930 2,435 HHUS210-2 81h 14 3Yi6 8'/e 3 130) 0,162 x 31h (10) 0.162 x 316 3. ,50 5,705 6.435 6.185 6.485 3.33 4.905 5.340 5.060 5,190 HGUS210-2 89A6 12 33i6 9316 4 (46) 0.162 x 31h (16) 0.162 x 31h 4.095 9.100 9,100 9.100 9.100 3,520 17.460 7,825 7,825 7.825 Triple 2x Sizes HGUS26 3 41346 12 4IV, 0.162 x 31h (8) 0.162 x 3 2,155 4,340 4,850 5.170 5.575 1,855 3,73D 4,170 4,445 4,795 IBC, FL. HGUS28-3 61346 12 410.162 x 31h (12) 0.162 x 3'h 3235 7,460 7.460 7,460 7.460 2,780 6.415 6,415 6,415 6,415 LA HHUS210.3 83'a 14 4 0.162 x 31k (10) 0.162 x 31h 3.405 5.630 6,375 6,485 6,485 2,930 4,840 5,485 5.575 5.575 FL HGUS210-3 8'3i6 12 40.162 Js5 t4(20) x 31h (16) 0.162 x 31h 4.095 9.100 9,100 9.100 9.100 3.520 7.825 7.825 7,825 7,825 HGUS212-3 10% 12 40.162 x 31h (20) 0.162 x 3'h 5,695 9,045 9,045 9.045 9.045 4.900 7,780 7,780 7.780 7. 880 lBC FL. LA HGUS214.3 12% 12 410.162 x 31h (22) 0.162 x 3 h 5,695 10,125 10,125 10,125 10.125 4,900 8,190 8,190 8.190 8,190 Ouadruple 2x Sizes HGUS26-4 516 12 63i6 5%6 4 (20) 0.162 x 31h 8) 0.162 x 3'/s 2,155 4,340 '4,850 5,170 5,575 1,855 3.730 4,170 4,445 4,795 IBC. FL, HGUS28-4 7'/a 12 6V% 73i6 4 (36) 0.162 x 31h (12) 0.162 x 316 3.235 7,460 7.460 7,460 7,460 2.780 6,415 6.415 6,415 6.415 LA HHUS210-4 Re 14 6'/s 8'/e 3 (30) 0.162 x 3112 (10) 0.162 x 31h 3,405 5,630 6.375 6.485 6,485 2,930 4.840 5.485 5,575 5.575 FL HGUS210-4 9'/4 12 69/4 9Y% 4 (46) 0.162 x 3'h (16) 0.162 x 31h 4.095 9,100 9,100 9.100 9.100 3.520 7.825 7,825 7,825 7.825 HGUS212.4 10% 12 6%e, 10% 4 (56) 0.162 x 31h (20) 0.162 x 31h 5.695 9,045 9.045 9.045 9,045 4.900 7.780 7,780 7.780 T780 IBC FL. LA HGU5214-4 126% 12 63'+6 12% 4 (66) 0.162 x 3'h (22) 0.162 x 31h 5.695 10,125 10.125 10.125 10.125 4,900 8,710 8,710 8.710 8,710 4x Sizes LUS46 4% 18 3% 43r4 2 (4) 0.162 x 31h (4) 0.162 x 3 h 1.060 1,030 1,170 1,265 1,595 010 885 1,005 1,090 1.370 IBC. FL HGUS46 4'h6 12 3% 4T/16 4 (20) 0.162 x 31h (8) 0.162 x 3'k 2,155 4.340 4,850 5.170 5,575 1,855 3,730 4.170 4,445 4,795 HHUS46 45/% 14 3% 53i6 3 (14) 0.162 x 31h (6) 0.162 x 31h 1,320 2,830 3,190 3,415 4,250 1.135 2.435 2.745 2,935 3.655 LUS48 43A 18 39iis 63/4 2 (610.162 x 3'h (4) 0.162 x 31h 1.060 1,315 1,490 1.610 2,030 910 1,130 1,280 1,385 1,745 16C, FL. HUS48 0'•`.4 14 34116 7 2 (6) 0.162 x 31h (6) 0.162 x 3'h 1,320 1.580 1.790 1,930 2,415 1,135 1.360 1.540 1,660 2.075 LA HHUS48 61/5 14 3% 71h 3 (22) 0.162 x 3112 (8) 0.162 x 3'h 1:; iii) 4.265 1 4,810 5.155 5,980 1.515 3,670 4,135 4,435 5,145 HGUS48 06 12 3% 7'`is 4 (36) 0.162 x 31h (12) 0.162 x 31h 3.235 7.460 17.460 7,460 7,460 2.780 6,415 6.415 6,415 6,415 LUS410 61/4 18 334e 83'4 2 (8) 0.162 x 31/z (6) 0.162 x 31h 4,445 1.830 2,075 2.245 2,830 1,245 1.575 1.785 1,930 2.435 HHUS410 8% 14 3% 9 3 (30) 0.162 x 31h (10) 0,162 x 31h 3,550 5.705 6,435 6.485 6,485 3,265 4.905 5.535 5.575 5,575 HGUS410 8'/16 12 3% 9Y6 4 (46) 0.162 x 31h (16) 0.162 x 3 Si 4.095 9,100 9,100 9,100 9,100 3,520 7,825 7,825 7,825 7,825 IBC. FL, LA HGU5412 10%6 12 311/9 101A6 4 (56) 0.162 x 31h (20) 0.162 x 31h 5 695 9.045 9.045 9.C1145 ..045 4,900 7,780 7.7,'X) 7.780 7.780 HGUS414 11 % 12 3% 12%6 4 (66) 0.162 x 31h (2210.162 x 31/2 5,695 10,125 10.125 10.125 10.i25 4.90D 8.190 8.190 8.190 8,190 Double 4x Sizes 7,820 7.820 HGOS7.37/10 8'/16 12 1 73i 8%, J 4 J (46) 0.162 x 3'h (16) 0.162 x 31/r 3.430 9,095 9.095 9.095 9,095 2,950 7.820 7,820 HGUS7.37/12 10'/6 12 73fr 10s 4 1 (56) 0162 x 31h (20) 0.162 x 31h 1 3,835 9,295 9,295 9,295 9,295 3.300 7,995 7,995 7,995 7,995 FL HGUS7.37114 11 ?F6 12 1 735 123,E 4 1 (66) 0.162 x 31h (22) 0.162 x 31h 5,080 10,50010,500 10,500 10,500 4,370 9,030 9,030 9.fl30 9,D30 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full tab€e loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com. 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSI/TPI 1-2014. Simpson Strong -Tie- Connector SefectW software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Strong -Tie, 5. Loads shown are based on a Nvo-ply 2x carrying member minimum for nailed hangers. with 3x carryng members, use 0.162' x 21h' nails in the header and 0.162' x 3'h' in the joist, with no load reduction. With single 2x carrying members, use 0.148' x 1 h* nars in the header and 0.148' x 3' in the joist. and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. IL I 195 UPDATED 12/01/20 HTU Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum nailing) apply to heel heights as low as 37/a'. Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Altemate allowable loads are prov ded for gaps between the end of the truss and the carrying member up to 1/2" max. to allow for greater construction tolerances (maximum gap for standard allowable loads is'/V per ASTM D1761 and D7147). See technical bulletin T-C-HANGERGAP at strongtie.com for more information. Material: 16 gauge 12 Finish: Galvanized 06 Installation: • Use all specified fasteners; see General Notes C C • Can be installed filling round holes only, or filling U round and triangle holes for maximum values • See alternate installation for applications 3 using the HTU26 on a 2x4 carrying member or H HTU28 or HTU210 on a 2x6 carrying member 'd for additional uplift capacity Options: d • HTU may be skewed up to 67 Y. See Hanger Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com for installation with Strong -Driver SD fasteners. Cotles: See p.12 for Code Reference Key Chan Mm, heel height per table t3Many of these products are approved for installation wth EArong-orn;e' SD Connector screws. See pp. 325-337 fw more information HTU26 truss and carrying member HTU Installation for Standard Allowable Loads go('h' manmum gap, use Alternate Allowable Loads.) Standard Aliowable Loads (1/8" Maximum Hanger Gap) SIMPSON Strong -Tie Typical HTU26 Minimum Nailing Installation Alternate Installation - HTU28 Installed on 2x6 Carrying Member (HI'U210 s+milar) Model Min. Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads Cade No. Heel Height W H g Carrying Member Carried Member Uplift (160} Floor (100) 1 Snow (115) Roof (125) Wind (160) Uplift (1601 Floor (100) Snow Roof (115)1 (125) Wind (160} Ref. Single 2x Sizes HTU26 3V6 14% 5'/rb 3'h (20) 0.162 x 3 �i (11) 0.148 x 11h 640 2.070 1 2,670 2,670 2,670 550 1.68{} 1,680 1,680 1.680 HTU26 (Min.) 3% 14% 51A6 31h (20) 0.162 x 31/2 (14) 0.148 x 1 Vi 1,250 2,940 3,200 3,200 3,200 1,075 1,852 2,015 2015, 2,015 HTU26 (Max.) 5Vi 15.% 57% 3'h (20) 0.162 x 31h (20) 0.148 x 11h 1,555 .2,940 3,320 3,580 4.010 1,335 2.530 2.855 3.080 3,450 IBC. HTU28 (Min.) 3'h 1 % 7 y1a 31h (26) 0.162 x 31h (14) 0.148 x 1 Va 1,235 3,820 3.895 3,895 3,895 1,060 2,865 2,920 1 2.920 2,920 FL, HTU28 (Max.) 7 /. 13% 7 Yie 31/2 (26) 0.162 x 31f2 (26) 0.148 x 1 Yz 2,02ii 3,820 4.315 4.655 5.435 1,l35 3,2$5 3,T 1(1 4,Oi}5 4,675 LA HTU210 (Min.) 3'/1 13% 9f5s 3'h (32) 0.162 x 31h (14) 0.148 x 116 1.330 4.300 4,300 4.300 4.300 1,145 3,225 3,225 1 3,225 _1225 HTU210 (Max.) 9Vi 15A 9A, 3'h {32) 0.162 x 3'h (32) 0.148 x 1 Fh 3.315 4,705 5.310 5,730 5,995 2,850 4,045 4,54335 1 41930 5,155 Double 2x Sizes HTU26-2 (Min.) 37/8 34i6 5'tis 3'h (20) 0.162 x 31h (14) 0.148 x 3 1.515 2.940 3.320 3.580 3,910 1.305 1.850 2.090 2.255 2,465 HTU26-2 (Max.) 5'h 3#e 5% 3'h {20) 0.162 x 31h (20) 0.148 x 3 2,175 2,940 3,320 3.580 4,480 1,870 2,530 2.855 3,080 3.855 HTU28-2 (Min.) 3'/s 3` T6 7 %e 3 h (26) 0.162 x 314 (14) 0.148 x 3 1.530 3,820 4.310 4.310 4,310 1,315 2.865 3.235 3,235 3,235 IBC. HTU28-2 (Max.) 7'ii 31As 7%6 3 r5 (26) 0.162 x 3'h (26) 0.148 x 3 3.485 3.820 4,315 4,655 5 325 2.995 3.285 3,710 4.005 5.01p LA LA HTU210-2 (Min.) 3'A 3%6 9AG 3Vr (32) 0.162 x 3 � (14) 0.148 x 3 1.755 4,705 4.815 4,815 4,815 1.510 3.530 3,610 3.610 3,610 HTU210-2 (Max.) 9V, 3`✓s 9Vrs 31h (32) 0.162 x 3Vi (32) 0.148 x 3 4,110 4.705 5.310 5,730 1 6.515 3.535 4.045 4,565 4.930 5.605 1, The maximum hanger gap is measured between the joist (or truss} end and the carrying member, 2. Minimum heel heights required for full table loads are based on a minimum 2 12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no lurther increase allowed. Reduce where other loads govern. 4. Wind (160) is a download rating. 3. For hanger gaps between 'A' and %V. ise the Alternate Allowable Loads. t;. Truss chard cross -grain tension may linrt allowable oads in accordance with ANSIITPI 1-2014, Simpson Strong-Tre° Connector Selector° software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Stfong-Tie. 1, Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148' x 11/2" nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table load B. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 196 HTU Face -Mount Truss Hanger (cont.) MMany of these products are approved for installation with Strong -Drive° SD Connector screws. See pp. 335-337 for more information. Alternate Installation Table for 2x4 and 2x6 Carrying Member Strong -Tie Min. Minimum Fasteners (in.) DF/SP Allowable Loads SPF/HF Allowable Loads Model No. Heel Height Carrying Cade Ref. Carrying Carried Uplift Floor Snow Roof Wind Uplift Floor Snow Roof Wind (in.) Member Member Member (160) (100) (115) (125) (160) (160) (100) (115) (125) (160) HTU26 (Min.) 37/s (2) 2x4 (10) 0.162 x 3112 (14) 0.146 x 1'h 647, 1.470 1,660 1.790 1.875 795 1,265 1,430 1,540 1.615 HTU26(Max.) 5'h (2) 2x4 (10) 0.162 x 31h (20) 0.148 x 1 h 1.240 1.470 1.660 1.790 2.220 101d5 1,265 1,430 1.540 1.910 IBC, HTU28 (Max) 71/4 (2) 2x6 (20) 0,162 x 31/2 1 (26) 0.448 x 11h 1.920 21940 3.320 3,580 3,905 1 1.650 1 2,530 1 2.855 3.080 3,360 FL. LA HTU210 (Max.) 9'/. (2) 2x6 (20) 0.162 x 31h 1 (32) 0.148 x 1 &1 2,860 2,940 3,320 1 3,580 1 3,905 1 2,475 1 2,530 1 2.855 13,080 1 3.360 1. See table below for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is W. 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21 22 for fastener snforrnaiiiiDL Alternative Allowable Loads (1/2" Maximum Hanger Gap) Min. Dimensions (in.) Fasteners (in.) DF/SP Allowable Loads SPFIHF Allowable Loads Model No. Heel Height W H D Carrying Carried Member Member Uplift (160j Floor (100) Snow (115) Roof (125) Wind (160) Uplift Floor (160j (100) Snow (115) Roof (125) Wind (160) Code Ref, Single 2x Sizes HTU26 3'h I % 5?A6 31h (20) 0.162 x 3'/a (11) 0.148 x 1 %z 635 2,395 2.395 2 395 2.395 545 1510 1 510 1.510 1,510 HTU26 (Min.) 3'/s 1 %5'/a 3'h (20) 0.162 x 31h (14) 0.148 x 11h 1.175 2,940 3,100 3.100 3,100 1.010 1,955 1,955 1.955 1.955 HTU26 (Max.) 51h 1 % 5'A5 3% (20) 0.162 x 3'h (20) 0.148 x 11h 1.215 2.940 3.320 3,580 3.630 1.045 1.850 2.090 2,285 2,285 IBC, HTU28 (Min.) 3'/s 15/e 7 s16 3'h (26) 0.162 x 3'h (14) 0.148 x 11/2 1,110 3.770 3.770 3,770 3.770 955 2.825 2,825 2.825 2,825 FL. HTU28 (Max,l 7'/. 1 % 711+6 31h (26) 0.162 x 31/s (26) 0,148 x 1'/2 1,920 3,820 :.:i15 1.655 5,015 1,695 2.865 :!,235 3,490 3.765 LA HTU210 'Min) 3'/s 1 % 9Y+s 31h (32) 0.162 x 31h (14) 0.148 x 1 h 1,250 3,600 3,600 3.600 3.600 1,075 2.700 2.700 2,700 2,700 HTU210 ;Max ;, 9'/4 15fa 9Ys6 3'h (32) 0.162 x 31z (32) 0.148 x 1'h 3,255 4,705 5,020 5,020 5 020 2.800 3.530 3,765 3,765 3,765 Double 2x Sizes HTU26-2 ;Min.) 3'/6 3�i6 5h6 31z (20) 0.162 x 3 t,� (14) 0,148 x 3 1,515 2,940 3.32C 3,500 3,500 1,305 2205 2205 2.205 2.205 HTU26 2 (Max.) 51h 3Na 59is 3 h (20) 0.162 x 3 h (20) 0.148 x 3 1,910 2,940 3.3ft. 3.500 3.500 1,645 2,205 2205 2.205 2.205 HTU28 2 ;Min.) 3'/9 3-166 7 Yi6 3'/z (26J 0.162 x 3 1h (14) 0.148 x 3 1.490 3.820 3,980 3.980 3,980 1.280 2,865 2,985 2,985 2,985 IBC FL HTU28-2 (Max) 71/4 3Vis 7Yi6 31h (26) 0.162 x 3'h (26) 0.148 x 3 3,035 3.820 4.315 4.655 5,520 2,610 2.865 3.= ? i 9.490 4 14;; LA HTU210-2 (Min) 3'/a 35/i6 9 vs 3'h (32) 0.162 x 31h (14) 0,148 x 3 1 1,755 4.255 4.255 4,255 4.255 1,510 1 3,190 3,190 3,190 3,190 HTU210.2 (Max.) 9114 Vie, 9 Ys 316 (32) 0.162 x 31h (32) 0.148 x 3 3,855 4.705 1 5,310 5,130 6,470 3.315 1 3.530 3.980 4,300 4,855 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table loads are based on a minimum 2:12 pitch. 3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern 4. Wind (160) is a download rating. 5. For hanger gaps between'/' and'/', use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may limit allowable loads in accordance with ANSIfTPI 1-2014. Simpson Strong -Tie' Connector Selector software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Strong -Tie. 7. Loads shrnvn are based on a minimum two-pty 2x carrying member. For single 2x carrying members. use 0.149- x 16 i nails in the header and reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table load. B. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. L 197 UPDATED 06/01/19 ■ HTU Face -Mount Truss Hanger (cont.) Options: See Hanger Options information on pp, 98-99, Skewed Seat • Skewable up to 67 h° • Available in single and two-ply size • No bevel cut required Allowable Loads for Skewed HTU Hangers Model No. Skew Angle (Degree) Fasteners (in,) DFISP Allowable Loads SPF/HF Allowable Loads Carrying Member Carried Member Uplift (160) Download (10011151125) Uplift (160) Download (10011151125) < 51 (20) 0.162 x 31h (14) 0.148 x 1'h 1.315 2,945 1,130 2.530 HTU26 51-671h (20) 0.162 x 3 h (12) 0.148 x 11h 970 2.595 835 2,230 < 51 (26) 0.162 x 3 h (20) 0.148 x 1'h 2.015 3 060 1730 2.630 HTU28 51.67 h (26) 0.162 x 3 h (17) 0.148 x 1 !6 1,485 2.815 1280 2,420 < 51 (32) 0.162 x 31h (26) 0.148 x 1 th 2.715 3,175 2,335 2,730 HTU210 51-671h (32) 0.162 x 3 h (22) 0.148 x 1'h 2.005 3,040 1.725 2,615 < 51 (20) 0.162 x 3'h (14) 0.148 x 3 1,335 2-555 1.145 2,200 HTU26-2 51-671h (2010]62 x 3'h (12) 0.148 x 3 1,110 2.700 955 2,320 < 51 (26) 0.162 x 31h (20) 0A48 x 3 2.470 3 890 2.120 3.345 HTU28-2 51-671h (26) 0.162 x 31h (17) 0.148 x 3 1,710 3.775 1,470 3,245 < 51 T (32) 0.162 x 3'h (26) 0.148 x 3 3,600 4 935 3.100 4.245 HTU210-2 51-671h (32) 0162 x 3 h (22) 0.148 x 3 1 2,255 4.790 1.940 4,120 1. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Allowable downloads may not be increased. 2. Maximum hanger gap between end of joist (truss) and face of carrying member is 1/8'. 3. Fasteners: Nait dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information "A^ 'Acute flange side Specify angle Top View HTU Hanger Skewed Right < 510 "A„ Specify angle 7 5V to 671/2° Top View HTU Hanger Skewed Right:, 51' Strong -'fie 198 74 Simpson Strong-T;el Wood Construction Connectors Multiple Truss Hip/Jack Hanger The THJU hip/jack hanger offers the most flexibility and ease of installation without sacrificing performance. The U-shaped hanger works for rrght- and left-hand hips and can be ordered to fit a range of hip skews (up to 67'/x°) as well as various single and 2-ply hip/jack combinations. Also can be installed before or after the hip and jack. THJt126 is sized for the standard hip/jack combination with a 45' left- or right hand hip, The wide seat of THJU26-W accommodates a 2-ply hip and 2-ply jack combination with a 45' maximum hip skew, or a standard single ply hiprjack configuration with a maximum 67'/s° hip skew. Intermediate seat widths are available for ether hipjack or hip/hip combinations. Material' 12 gauge Finish: Galvanized installation: • Use all specified fasteners; see General Notes Options: • THJU is available in intermediate seat widths between 51/a" (THJU26 width) and fir/a' (THJU26 W width) with no load reduction, • For double -hip installation, divide the total allowable load by 2 to determine the allowable load for each hip. Order as THJU26X and specify width; see table for reference. • Allowable download and uplift for all intermediate widths is 100% of the THJU26-W table loads. Codes, See p.12 for Code Reference Key Chart THJU26 1'h' -t I':-. 1Yp. work ng point THJU26-W Top View Two -Ply Hip/Two-Ply Jack Installation THJU Intermediate Width Options SIMPSON Strong -Tie Typical THJU26 Installation , N 1W typ. ti working 45° point THJU26 Top View Right -Hand Hip Installation Carried Member Combination Hip Skew Width (W) 2-ply hip and single -ply jack 45' 63A Single -ply hip and 2-ply lack 45° 63', Double (terminal) hip 45' 73f; 2-ply hip and 2-ply jack 45' Use THJU26-W Single -ply hip and single -ply jack 44'— 46' Use THJU26 47`-49' 51/2 50°- 52° 531. 53°- 55' 6 56'- 57° 6% 58°-59° 1 6ya 60°-61° 7 620-63° 1 7-% 64'-65° 1 Use THJU26-IN + W THJU Top View Installation Dimensions (in.) Fasteners (in,) DFlSP Allowable Loads SPFIHF Allowable Loads Model Min. Carried Download Download Code No, Member WTH Carrying Member Hip Jack Uplift (160) Floor Snow Roof Wind Uplift (160)EF Snow Roof Wind Ref. (100) (115) (125) (160) (115) (125) (16D) 2x4 3 (4)0.148x3 (4) 0.148 x 3 780 1,915 1,915 1,915 1.915 670 1,645 1,645 1,6452x6 THJU26 5'!a 5:Y 3'/i(1610.148x or end. vert. (16)0.148x3 (7)0.148x 3 (7) 0.148 x 3 1,310 2,255 2.350 2,350 2.350 1,125 2.020 2.020 2,020 18C THJU26-W 2x4 8'/e 538 31k (16) 0.148 x 3 (4) 0.148 x 3 (4) 0.148 x 3 685 1.825 1,825 1,825 1,825 590 1,570 1,570 1.570 1,570 FL (16) 0.148 x 3 (7) 0.148 x 3 {7) 0.148 x 3 1,240 t,965 1,965 1,965 1.965 1.065 1.690 1.690 1,690 1,690 2x6 ar end. veil? 1. Tabulated loads are the total allowable loads of the hip and jack members combined; 655. 8Yq of the total ladd shall be distributed to the hip member, and the remaining percentage of the total oad shall be distributed to the jack. The combined hip and pack load may not exceed the published total load. 2. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce wtkre other loads govern. 3. For full -oad. the lack requires either a minimum 2x6 bottom chord or a minimum 2x4 end verticat the hip requires either a minimum 2x6 bottom chord or a minimum 2x6 end vertical for hip skews up to 50 For hip skews greater than 60' (THJU26- W onh-i, a minimum 2x6 bottom chord or minimum 2x3 end vertical is required 4. With single 2x carrying members, use 0,148' x 11/2' nails and use t00-c of the table value. 5. For single 2x jacks. 0.148' x 11/2' nails may be substituted for the specified 0.148' x 3- with no reduction in load. 6. Truss chord cross -grain tension may limit ailovrable loadz, in accordance with ANSlrTPI 1.2014, Simpson Strong -Tie' Connector Selector' software includes the evaluation of cross -grain tension in its hanger ailovrable toads. For additional information, contact Simpson Strong -Tie, 7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21 22 for fastener information.