HomeMy WebLinkAboutAPPROVED Design PressuresFloridaWindow & DoorC(2 1125 N. Dixie Hwy Lake Worth, FL 33460 Information Owner: Thomas McNally Jr Address: 8305 Salerno Rd Fort Pierce, FL 34951 Tel. (561) 848-4900 floridawi ndowanddoor.com Building Information Wind Zone: 165 MPH. Exposure Category: D Minimum Building Dimension: 35 ft. Mean Roof Height: 12 ft. Risk Category: II Desii!n Pressure Calculations 1 Opening Location Device 11 Device Device 11 Max Positive 11 Max Negative Number IL Zone Width (in) IL Height (in) Elevation (ft) Pressure (psf) IL Pressure (psf) 1 End 37 80 7 41.2 -53.8 2 End 36 50 7 42.6 56.6 3_ End 36 38 7 43.2 57.9 4 End 25 25 7 43.2 -57.9 5 End 36 50 7 42.6 56.6 6 End 36 _ 50 7 42.6 56.6 7 End 25 25 7 43.2 57.9 8 End 52 38 7 42.3 56.1 9 End 36 38 7 43.2 57.9 10 End 25 25 7 43.2 57.9 11 End 36 38 7 43.2 57.9 12 End 52 38 7 42.3 -56.1 13 End 36 50 7 42.6 56.6 14 End 36 50 7 42.6 56.6 Prepared in accordance with: ASCB 7-16, Chapter 30. F1lind Loads - Components and Cladding. 71h Edilion (2020) Florida Building Code. Page I of 1