HomeMy WebLinkAboutAPPROVED Design Pressure Report (Earl Gardner) - Florida Window & DoorProperty Information Owner:Earl Gardner Address:1701 N 35th Street Fort Pierce, FL 34947 Building Information Wind Zone:165 MPH. Exposure Category:C Minimum Building Dimension:35 ft. Mean Roof Height:20 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 23 56 10 37.8 -50.7 2 End 22 56 10 37.8 -50.7 3 End 22 56 10 37.8 -50.7 4 End 22 56 10 37.8 -50.7 5 End 22 56 10 37.8 -50.7 6 End 23 56 10 37.8 -50.7 7 End 32 76 10 36.5 -48.1 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1