HomeMy WebLinkAboutDesign Pressure Report (Benjamin McColister) - Florida Window & Door Florida Window & Door Co. 1 125 N.Dixie Hwy Tel.(561)848-4900 LakeWorth, FL 33460 Floridawindowanddoor.com Property Information Building Information Owner: Benjamin McColister Wind Zone: 165 MPH. Address: 4901 Paleo Pines Cir Exposure Category: C Fort Pierce,FL 34951 Minimum Building Dimension: 45 ft. Mean Roof Height: 10 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) J Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 End 26 63 7 35.3 -47.1 2 End 26 63 7 35.3 -47.1 3 End 37 77 7 34.0 -44.5 4 End 37 77 7 34.0 -44.5 5 End 37 77 7 34.0 -44.5 6 End 48 32 7 35.5 -47.4 7 End 26 63 7 35.3 -47.1 8 End 74 63 7 32.9 -42.2 9 End 111 63 7 31.9 -40.4 Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code. Page 1 of 1