HomeMy WebLinkAboutFL 1in Snap 24 GA Metal Alliance �n� , till era
V
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
Iq USER: Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL29523-R1
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Metal Alliance Inc.
Address/Phone/Email 2120 SW Poma Dr.
Palm City,FL 34990
(844)638-2548
orders@metalalliance.com
Authorized Signature Tara Faulkner
orders@metaialliance.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2030
Validated By James R Wally,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL29523 R1 COI 32AI 100SL p1vwood nonHVHZ.p_df
Referenced Standard and Year(of Standard) Standard Year
TAS 100 1995
TAS 125 2003
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/11/2020
Date Validated 08/13/2020
Date Pending FBC Approval 08/19/2020
Date Approved 10/13/2020
Summary of Products
FL# Model,Number or Name Description
29523.1 01: 100SL 1"Nailstrip 032 Aluminum 100SL 1"Nailstrip panel from nominal 0.032"aluminum or
thicker on 15/32"(min)plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL29523 R1 II 32AI 1005L p1 wood nonHVHZ.p�.f
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: 168.5 psf @ 6"oc FL29523 Ri AE 32AI 1005E plywood nonHVHZ.pdf
Independent Third Party:Yes I
523.2 02: 100SL 1"Nailstrip 24ga 100SL 1"Nailstrip panel from 24ga nin)on 15/32" (min)
plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
p Approved for use in HVHZ:No FL29523 R1 II 24ga 100SL plywood nonHVHZ.p
9 Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-206 Evaluation Reports
her: 206 psf @ 6"oc FL29523 R1 AE 24ga 100SL p1Ywo n n V df
Cr
29523.3 03: 100SL 1"Nailstrip 26ga HVHZ 100SL 1"Nailstrip panel from 26ga (min)on 15/32"(min)
plywood or 3/4"(min)wood plank
Limits of Use — — Installation Instructions
Approved for use in HVHZ:Yes FL29523 R1 11 26ga 100SL plywoo psf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-176 Evaluation Reports
Other: 176 psf @ 6"oc WITH sealant, 116 psf @ 6"oc without FL29523 R1 AE 26ga 100SL olywood.Qj
sealant Created by Independent Third Party:Yes
29523.4 04: 100SL 1"Nailstrip 032 Aluminum 100SL 1"Nailstrip panel from nominal 0.032"aluminum or
HVHZ thicker on 15/32"(min)plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL29523 R1 II 32AI 100SL plv 22 p�
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-175 Evaluation Reports
Other: 175 psf @ 6"oc WITH sealant FL29523 R1 AE 32AI 100SL plywood.p�
Created by Independent Third Party: Yes
_.i_
29523.5 j 05: 150SL 1.5"Nailstrip 24ga 150SL 1.5"Nailstrip panel from 24ga(min)on 15/32"(min)
plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL29523 R1 II 24ga 150SL plywood nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng, PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-153.5 Evaluation Reports
Other: 153.5 psf @ 6"oc WITH sealant FL29523 R1 AE 24ga 150S- g_lywood nonHVHZ.pd
Created by Independent Third Party:Yes
29523.E 06: 150SL 1.5"Nailstrip 032 — 150SL 1.5"Nailstrip panel from nominal 0.032"aluminum or
Aluminum thicker on 15/32"(min)plywood or 3/4"(min)wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL29523 R1 II 32AI 150SL plywood nonHVHZ.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: 168.5 psf @ 6"oc WITH sealant FL29523 R1 AE 32AI 1505L gJywood nonHVHZ.gd
Created by Independent Third Party: Yes
29523.7 07: 150SL 1.5"Nailstrip 032 150SL 1.5"Nailstrip panel from nominal 0.032"aluminum or
Aluminum HVHZ thicker on 15/32"(min)plywood or 3/4"(min)wood plank 1
19"coverage
Limits of Use Installation Instructions
i
Approved for use in HVHZ:Yes FL29523 R1 II 32Al 1505L_olywood.p�
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-168.1 Evaluation Reports
Other: 168.1 psf @ 6"oc WITH sealant FL29523 R1 AE 32AI 150SL plywood.pdf
Created by Independent Third Party: Yes
29523.8 O8: 150SL 1.5"Nailstrip 24ga HVHZ 150SL 1.5" Nailstrip panel from 24ga (min)on 15/32"(min)
plywood or 3/4"(min)wood plank 1 19"coverage
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL29523 R1 II 24ga 150SL plywood.pdf
Approved for use outside HVHZ:Yes Verified By: David Eng,PE 81377
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-112.5 Evaluation Reports
Other: 112.5 @ 6"oc WITH sealant FL29523 R1 AE 24ga 150SL pjywood.pdf
Created by Independent Third Party: Yes
j
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer,gopyrlaht 2007-2013 State of Florida,::Privacy Statement::Accessibility Statement::Refund Statement
I
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(i),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F,S.,please click here.
Product Approval Accepts:
® eCeEck I
I
Credit Card
Safe
I
III
II
I
I
III
I
ii
I
Aik
MIIETAULLIANUL
A Value Added Supplier of Metals
1 " Na i IStri p 24ga Steel Panels
24ga (min) 1" Nail Strip over 15/32" (min ) plywood
Metal Alliance, Inc
2120 SW Poma Dr I Palm City FL 34990
Produced by Metal Alliance's Network of Approved Regional Manufacturers
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
24ga (min) steel
24ga is nominally 0.0239" with yield strength of at least 50ksi, and shall be corrosion
resistant per FBC 1507.4.3 where required.
Fastener
#10 1-inch pancake style fastener
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE \\Illlllll�i�r,
Timberlake Cove, L L C
3324 w Univ Ave #206 l Gainesville FL �� O.•'• L\CENSF '••�i �
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com No. 81377
-_-0
� 0 STATE OF
.FCORIOP.•' GN
S �
Divid E Eng
2020.08.10
100SL 18:45:33-04'00'
This item has been digitally signed and sealed
by D.E. Eng,PE,on the date indicated. Printed
1" NAI LSTR I P 24GA copies of this document are not considered
signed and sealed and the signature must be
verified on any electronic copies.
Underlayment: Comply with local building code or FBC 1507.1.1 where required.
Slope: Comply with local building code or FBC 1507.4.2 where required.
Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511, provided the existing roof meets the conditions required by
the applicable code.
Maximum Allowable Loads & Installation Requirements:
Metnod, A_ #10 x I" fastener at 6" o.c. alona nail strip_206 PSF
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre-punched slots.
Technical Documentation:
This product has been tested to the UL 580 standard by Intertek Testing (TST-1527), report
J6368.05-450-44 RO.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2
(non-HVHZ) as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any
company manufacturing or distributing products under this evaluation. The same entities do
not have, nor will acquire, a financial interest in any other entity involved in the approval
process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be
completed by others. Fire classification and shear diaphragm design are outside the scope of
this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as
required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible
for any conclusions, interpretations, or designs made by others based on this evaluation
report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no
express or implied warranty regarding performance of this product.
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use
of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
METAULLIANE'l
A Value Added Supplier of Metals
ENGINEERING LOAD TABLES
Instructions: ✓' a
Select the appropriate load table that applies to ,�� ��-"� --w2 -- 2 ---�- 3
the structure in question.
Determine the design wind speed for the project j .
�2 1 1 2
location.
Use the attachment method indicated for that i2 1
wi -idspeed within each roof zone.
2,r i
N<:1TE: ASCE 7-16 and FBC 2020 adopt a 7-zone I/ i2// 1 ` 1 2
concept. For the load tables below, the worst case f
was taken for each zone and reported using the a 3 -� 3 a
standard zones 1-2-3:
Zane 1 includes zones 1 and 1' -�a� HIP ROOF GABLE ROOF —a—
Zone 2 includes zones 2e, 2r, and 2n
L 10".a OF LEAST HOIZONTAL DIMENSION OR O4R.W141CPrEVER IS SMALLER GUT N')'.
Zane 3 includes zones 3 e and 3 r
LESS THAN EITHER 4-OF LEAST HORIZONTAL DIMENSION OR 3"IOW)
OR AS DE TCRMINLD BY DESIGN OR OTHER APPLICABLE COD[.
Combining these zones creates a clear, simple ROOF ZONES FOR GENERIC BUILDING
scheme, at the expense of some design efficiency. -- -- - ---
Contact Metal Alliance Inc for further information,
or consult a licensed design professional.
METHOD A
FFMALF LEG SNAPS
ONTO MALE LEG
#10 FASTENER
A16 0C
Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B,C,or D exposure area
Have Either a flat roof,or gable/hip roof with max slope of 451 Have either a flat roof,or gable/hip roof with max slope of 451
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
171-29523.02: 24 a 100SL 1" nail strip on 15/32" plywood FL29523.02: 24 a 100SL 1" nail strip on 15132" plywood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A
Zone 3: A A A A A A A A A A A Zone 3: AAA AAA AA A
Use th s load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria.-
Are located in Exposure B area Are located in B,C,or D exposure area
Have tither a flat roof less than 70, hip roof with Have either a flat roof less than 70,hip roof with
max slope of 450,or gable roof with slope between 20'and 45° max slope of 450,or gable roof with slope between 200 and 450
Havee mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL29523.02: 24 a 100SL 1" nail strip on 15/32" Plywood FL29523.02: 24 a 100SL 1" nail strin on 15/32" Plywood
Windt 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A
Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A A ' NR
METAULLIA11UL
A Value Added Supplier of Metals