ENERGY CALCS & MANUAL J - 150 CAMINO DEL RIO(1)
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County! St Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type$1432.0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 ft2 b.Frame-Wood,Adjacent R=11.0 208,00 ft2 3. Number of units,if mul iple family 1 c.NIA R= ft2 4. Number of Bedrooms 3 d.NIA R= ft2 11.Ceiling Types (1783.0 sgft.) insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30"0 1753.00 ft2 6. Conditioned floor area above grade(ft2) 1753 b.Knee Wall(Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 c.NIA R= f#2 7. Windows(151.4 soft.) Description Area 12.Ducts R ft2 a. U-Factor: Sgl,U=1.02 111.3i5 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft2 13.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth. 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 B. Skylights Area c. U-Factor:(AVG) NIA ft2 15,Hot water systems SHGC(AVG): NIA a.Electric Cap:40 gallons 9. Floor Types (1753.0 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. NIA R= ft2 None c.NIA R= ft2 16.Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 I hereby certify that the plans and specifications covered by Review of the plans and 10E$-Z this calculation are in compliance with the Florida Energy specifications covered by this azz Off, Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed W DATE: 1-12-20211 this building will be inspected for lEl compliance with Section 553.908 hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy CO �D WS OWNERIA�NT' BUILDING OFFICIAL: DATE: t �-�� DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 1/12/2021 1:15 PM EnergyGaugee)USA 7.0.00-FlaRes2020 F8C 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, Newl&dsting: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.6% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Intl[ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 735 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft _- 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' ---- 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' --_ 0 1 0 4SIab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft' ___ 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft- -_ 0 1 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 180 IF 0 1 0 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' -r 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN lift 0 209 ft- _ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 5 ft 0 50 ft- ___ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft- — 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft. — 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type, Area Framing Free Truss Type 1 Under Attic(Vented) MASTER SEDRO 30 Blown 224 ft2 0.1 Wood _ 2 Under Attic(Vented) WIC 30 Blown 63 R2 0.1 Wood _ 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ftz 0.1 Wood _ 4 Under Attic(Vented) M.BATH 30 Blown 61 ft2 0.1 Wood _ 5 Under Attic(Vented) LAUDRY 30 Blown 36R 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood 7 Under Attic(Vented) DININGIGREAT 30 Blown 588ft' 0.1 Wood _ 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft- 0.1 Wood _ 9 Under Attic(Vented) BATH 30 Blown 50 ft2 0.1 Wood _ 10 Under Attic(Vented) HALL 30 Blown 25 ft2 0.1 Wood _ 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood _ 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 iN 0.1 Wood 13 Knee Wall(Vented) DINING/GREAT 19 Blown 30 fC 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 NE=>SW Exterior Concrete Block-Int InsMASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.3 0 2 SW=>NE Exterior Concrete Block-Int InsUASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 3 NW=>SE Exterior Concrete Block-Int Ins811ASTER BE 4.1 14 0 8 0 112.0 ft- 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space o -4 NE=>SW Exterior Concrete Block-Int InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _ 5 NE=>SW Exterior Concrete Block-Int Insul M.BATH 4.1 7 0 8 0 56.0 ft- 0 0 0.3 0 6 NE=>SW Exterior Concrete Block-Int InsBIEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 _ 7 SW=>NE Exterior Concrete Block-Int Ins(RINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 8 NW=>SE Exterior Concrete Block-Int lnsGINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 9 SW=>NE Exterior Concrete Block-Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _11 SE=>NW Exterior Concrete Block-Int Insul FOYER 4.1 8 0 8 0 64.0 ft- 0 0 0.3 0 12 SW=>NE Exterior Concrete Block-Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 NE=>SW Exterior Concrete Block-Int Ins%EDROOM 3 4.1 13 0 a 0 104.0 ft2 0 0 0.3 0 14 SW=>NE Exterior Concrete Block-Int InsBBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N=>S Garage Frame-Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => chancied to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft2 1 ft 0 in 1 It 4 in Drapes/blinds Exterior 5 _ 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 4 in None None _ 3 NE=>SW 6 Metal Low-E Single Yes 1.02 029 Y 16.2 ft- 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft2 1 ft 0 in 1 It 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft2 8 It 0 in 1 It 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft2 Attic 55 ft- Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans: Cooling [[ ]]Jan [[ �Feb [[]]Mar [ ]Apr [ ]]Ma [X�Jun D0 Jul [X]Au �XI Se Oct r 'Nov Dec Venting [X]Jan H Feb N Mar [ ]� I 1 May [ 7 Jun [ )Jul [ ]A E 1 Step Oct M Nov Dec Veati Klan Jan [I ]]Feb l[�X1J Mar IXl III may [ )Jun I )Jul I ]Augv ) Oct I Nov H Dec Thermostat Schedule: HERS 20D6 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) PM 78 78 78 8 78 78 78 78 78 78 78 78 Cooling(WEH) PM 78 78 8 78 78 78 8 78 78 78 78 78 Heating(WD) 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(81bslsq.fL 0 ft2 O ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft- ft 0.3 M.BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUDRY Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 DININGIGREAT R Default(8 lbs/sq.ft- ft2 ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft ft' it 0.3 BATH Defauft(8 lbs/sq-ft. ft ft 0.3 HALL Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default B lbs/s .ft. ft2 ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyCauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Y Owner. Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. ts requiremen Breaks or joints in the air bander shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity,insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind pinino and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box ot The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire son Is DE CE111120S. L a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index,the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 ft' b. Frame-Wood,Adjacent R=11.0 208.00 ft' 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 3 d.N/A R= ft' 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ft' 6. Conditioned floor area(fF) 1753 b.Knee Wall(Vented) R=19.0 30.00 ft' 7. Windows** Description Area c.N/A R= ft= a. U-Factor: Sgl,U=1.02 111.36 ft' 12.Ducts,location&insulation level R ft' a.Sup:Attic,Ret:Attic,AH:Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a.Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A fl? 14.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 2,850 ft. Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15.Hot water systems a. U-Factor AVG: N/A ftT a.Electric Cap:40 gallons ( ) EF:0.97 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft' Credits(Performance method) None b.N/A R= ft- c.N/A R= ft- I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) tiO4� 0 in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,,, based on installed Code compliant features r„ - - BuilderSignature: �� Date: r Addressof New Home: \S� CoQrt\%-c\ p City/FLZip: Cps WS,tg� 42\ . ) *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 wrightsoft® Project Summary Job: Entire House BY QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr.PIERCE,FL 34946 Ptnra:772-466-6799 Fax 772466-6796 Emil:OUICKCALCS@A.OL.COM Proiect Information For. WYNNE DEVELOPMENT THE WINDSOR,FT.PIERCE,FL Notes: Design Information Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 Inside db 70 OF Inside db 75 °F Design TD 28 OF Design TD 15 OF Daily range I Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Btuh Duds 9337 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfikn) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft2) 1753 1753 Equipment latent load 5041 Btuh Volume(fl) 16478 16478 Air changesihour 0.38 0.20 Equipment Total Load((Sen+Lat) 29511 Btuh Equiv.AVF(dfn) 104 55 Req.total capacity at0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Caner Trade CARRIERAIRCONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 Cond 25HBC536A 030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47°F Latent000ling 10440 fth Temperaturense 27 OF Total cooling 34800 Btuh Actual airflow 1160 Cfm Actual air flow 1160 cfm Airflowfactor 0.042 cfmBtuh Airflowfador 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=36 OF Backup: Input=7kW, Output=23009 Blur,100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -FP- wrilghts ft® 2021-Jan1213:18:18 • ^^—�^a^+ NgitStiL@ Unv ml201919.021 RSU08101 Page 1 /LCN _.Dow ris\WnghLrottM/AgWYNNE-THEWINDSORnp Calc=M16 Fror¢Doorfrces:N wrighWofr Right-J@ Worksheet Date: Entire House Sy- QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr.PIERCE,FL 34946 PIrore:772-466-6799 F.T 2-066-6796 Email:OulC CALLS AOL.COM 1 Room name Entire House BEDROOM 2 EVosedydl 207.6 ft 41.0 R 3 Room height SA R d 9.4 ft heaUmol 4 Room dimensions 14.0 x 20.0 it 5 Room area 1753.0 ft' 280.0 R° Ty I Construction U-value Or HTM rea A OF) Load Area (T) Load number (BWh/F-'F) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 Vy 13A4= 0.143 n 4.00 255 649 596 2386 1517 66 66 263 167 L--G 1Aclom 1270 n 3556 34.77 15 0 533 522 0 0 0 0 l—r" 4P5-20m 0.770 n 2156 1931 38 0 815 730 0 0 0 0 W 13A4= 0.143 ne 4.00 2.55 27 27 106 68 0 0 0 0 11 vt/ 13A4ors 0.143 a 4.00 2,55 141 100 400 255 0 0 0 0 �G 1Ac1an 1270 a 3556 87,06 20 1 711 1741 0 0 0 0 I---D 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4o s 0.143 se 4.00 2.55 27 27 106 68 0 0 0 0 W 13A4as 0.143 s 4.00 2.55 536 530 2121 1349 186 188 753 479 I—C 1Aciam 1270 s 3556 34.77 6 6 213 209 0 0 0 0 13A-4ors 0.143 w 4.00 2.55 320 255 1022 649 132 108 432 275 I--G tActom 1270 w 35M 54M 12 1 415 636 12 1 415 636 IL--cG 1Actom 1270 w 3556 54.53 12 1 427 654 12 1 427 654 4A5-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-09N 0.091 255 128 254 254 647 326 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 650 F 22A-tpl 0.989 - 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 c)AEDe rson 397 488 Envelope loss/gain F21542 15285 3676 3349 12 a) Infiltration 905 729 205 b) Roonn entilation 0 0 0 13 Intemalgains: O=panls@ 230 1 230 0 0 Applianoslotner 0 0 subtotal(lines6toi3) 16420 4405 3554 Les e�mal load 0 0 0 Leastran4er 0 0 0 Redishibubw 0 0 0 0 14 Subtotal 21542 16420 4405 3554 15 Dudioads 29% 57% 6191 9337 29% 571. 1266 2021 Total room load I 27734 25757 5671 5575 Air required(dm) 1160 1160 237 251 _ Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. . :A� W�19ti'tAha 2021-Jan1213:18:18 RIgfSdL0Unvarw12019l9.021 RSU08101 Page 1 ,,,Doairs \WngF ftHVAQWYNNE-THEWINDSORfup Calc=MlB Front Doorfaces:N Fb wrightsow Right-J®Worksheet Date: Entire House BY By. QUICK CALCS, INC. 317 ST.LUCIE UN.,Fr.PIERCE,FL 34946 PIune:772-46&6799 fax 772.466-6796 EMI:QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 E1rposadwall 0 It 9A It 3 Room height 9.4 ft heaVmof 94 It heatltlm.W 4 Room dimensions 7.0 x 9.0 It 7.0 x 9.0 ft 5 Room area 63.0 fF 63.0 fe Ty Construmon U-value Or HTM Area (fF) Load Area (M Load number (BWhfi?z-F) (BWW or perimeter (ft) (BWh) or penmeter (ft) (SWh) Heat Cool Gross N/P,S Heat Cool Gross NIPS Heat Cool 6 T- 13A-4= 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 G 1Aatan 1270 n 3556 34.77 0 0 0 0 0 0 0 0 -G 4A5-2om 0.770 In 21.56 19.31 0 0 0 0 0 0 0 0 W 13A-4a<s 0.143 m 4.00 2.55 0 0 0 0 0 0 0 0 11 V/ = 13A-4ors 0.143 a 4.00 2S5 0 0 0 0 0 0 0 0 IL---GD 1A,cl m 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 se 4.00 255 0 0 0 0 0 0 0 0 t13A4o s 0.743 s 40 2m 0 0 0 0 85 85 339 215 -C %dom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 y/ 13A40s 0.143 w 4A0 255 0 0 0 0 0 0 0 0 {-G 1Acloh 1270 w 35.56 5453 0 0 0 0 0 .0 0 L-.GG 1A Iom 1270 w 3556 54M 0 0 0 0 0 0 0 0 4A5-20m 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-Os 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 22A4pl 0.989 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AED murston -10 -28 Envelope loss/gain 56 136 694 334 12 a) Infiltration 0 0 160 45 b) Roomserdlaton 0 0 0 0 13 Internal gains: Ooarpants@ 230 0 0 0 0 Agpliancasbtver 0 0 SubWtel(lines6b13) 56 136 804 379 Lesse*malload 0 0 0 0 Lestransfer 0 0 0 0 Re& ibution 0 0 0 0 14 Sub 804 136 804 379 15 Ouctloads 29% 57% 16 77 29% 57% 237 276 Total room load 73 211 1036 595 Air required(cfm) 3 10 43 27 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. -f}F wri9y�o�` 2021Jan�1213:18:18 .9C Wgh.$ute@Udversa720t919.021 RSU0810t Page ...Coa rtAWngftwft HVACrWYNNE-THEWINDSOR.np Calc=hM FrortDoorfams:N f�F wrightsoft RighW@ Worksheet Dat Entire House BY. By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT PIERCE,FL 34946 Ptnre:T72-466-6799 Fax 772115M796 Email:QUICKC4LCS@AOL.COM 1 Room name N1 BATH KITCHEN 2 Evosedwall 8.0 ft 8.0 It 3 Room height 94 It heatloxl 9.4 ft heaYmol 4 Room dimensions 7.0 x &0 ft 1.0 x 1720 t 5 Room area 56.0 T 172.0 1R Ty Construction U-value Or HTM Area OF) Load Area (fte) Load number (BWh4l F) or perimeter (it) (BWh) or perimeter (1t) (BWh) Heat Cool Gros NIPS Heat Cool Gros N/P/S Heat Cool 6 13A-0as 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Aolom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4AS-20M 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 w 13A-4ors 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 V� 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 - 0 0 I-G 1A-clom 1270 a 36,56 87.05 0 0 0 0 0 0 0 0 L-D 11D0 0.390 a 1022 1131 0 0 0 0 0 0 0 0 W 13A4oas 0-143 se 4.00 2M 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.55 75 69 277 176 0 0 0 0 I-G 1A-c1om 1270 s 3556 34.77 6 6 213 209 0 0 0 0 V�1 13A.4ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 �G tAoiam 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1A-c1om 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A`.2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 2.55 128 0 0 0 0 75 75 192 95 C 16A-30md 0.032 - 0.90 232 56 56 50 130 172 172 154 399 F 22A-tpl 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 c)AED e=rSlon -38 34 Envelope loss/gain 762 477 567 462 12 a) Infiltration 142 40 0 0 b) Roomventilation 0 0 13 Internal gain Ooaopants@ 230 0 0 0 0 Appliancesiother 0 0 Subtotal(lines 6 to 13) 904 517 567 462 Lesextemai load 0 0 0 0 Lestrznsier 0 0 0 0 0 0 0 0 Redisfibuton 14 Subtotal 260 294 563 263 15 Duct loads 29% 57°/, 260 294 29% 57°h 163 263 Total room load 1164 8" 730 725 Air required(dm) 49 37 31 33 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -!'FF wr✓f9�!,,„_rsMc' 2021 Jarv727.� Page A RigMSuteNJ Uriversa1201919.021 RSU08101 Pz9e 3 ...DoamerOWngh5oftWAMWYNNE-THEWINDSORnp Calc=M18 Front Doorfamv.N r�+wrightsofr Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST.LUCIE LN.,Fi PIERCE,FL 34946 Pt re:772-466-6799 F=72466-6796 Email:QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM2 2 5posd wall 5.0 It 42.6 It 3 Room height 9.4 ft heaYcool 9.4 It heaV=l 4 Room dimensons 9.0 x 5.0 It 1.0 x 204.0 It 5 Room area 45.0 IF 204.0 T Ty Constudon U-value Or HTM Area Load number (BNhAF--g (BWhfin or perimeter (ft) (Bbh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/5 Heat Cool Gross NIPS Heat Cool 6 V 13A4a 0.143 n 4.00 2.55 47 47 188 120 132 132 527 335 ��GG 1AC1om 1270 n 3556 34.7 0 0 0 0 0 0 0 0 4A5.2om ono n 2156 1931 0 0 0 0 0 0 0 0 W 13A4w 0.143 ne 4.00 255 0 0 0 0 27 27 106 68 11 13A4= 0.143 a 4.00 255 0 0 0 0 85 65 259 164 1A lom 1270 e 35M 87.06 0 0 0 0 20 1 711 1741 III--DDD 11DO 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 W 13A4os 0.143 se 4.00 255 0 0 0 0 27 27 106 68 Vd 13A-0acs 0.143 s 4A0 2.55 0 0 0 0 132 132 527 335 —G 1A-clom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 1A-dom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-OSN 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 090 2.32 45 45 40 104 204 204 183 473 F 22A-tpl 0989 - 27.69 0.00 45 5 138 0 204 43 1179 0 6 c)AED e=rsim -17 -99 Envelope loWgain 367 207 35% 3085 12 a) Infiilhation 89 25 758 214 b) Room ventilation 0 0 0 0 13 Intertlal gains: Ooaipants@ 230 0 0 0 0 ApplimoeSbther 0 0 Subtotal(hrn 6to 13) 456 232 4357 3299 Lesexbmalload 0 0 0 0 Lestw'der 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 456 232 4357 3299 15 Ductloads 29% 57% 131 132 29% 57% 1252 1876 Total room load 587 364 5609 5175 Air required(cSm) 25 16 235 233 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. wtri9hfsofi' 2021Jarv1213:18:18 '^ Rigl4SUL&L;ri ersa1201919.021 RSU08101 Page ...Docvrer6lWdghi otWACWY NE-THEWINDSORrup Calc=M18 Frcrrtl)oorface N +� wrightsoftt RighW@ Worksheet Job. Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE UN.,Fr.PIERCE,FL 34946 Phore:772-466-6799 Fax 7724666796 Email:QUICKC4LCS@40LCOM 1 Room name ENTRY LAUNDRY 2 Enposadwall 18D It 13.0 it 3 Room height 9.4 It heatlmol 9A it heatlmol 4 Room dimensions ID x 92.0 It 7.0 x 6.0 it 5 Room area 92D 1F 42.0 1F Ty Construction U-value Or HTM Area (ft� Load Area (H� Load number (BhlhdF.q (BWhflF) or perimeter (ft) (BNh) or perimeter (it) (BWh) Heat Cool Gros NiPl3 Heat Cool Gross NIPIS Heat Cool 6 Vy 13A4= 0.143 n 4.00 255 0 0 0 0 0 0 0 0 II--G' 1A-dom 1270 n 35.56 3477 0 0 0 0 0 0 0 0 I 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 W 13A4= 0.143 m 4.00 2,55 0 0 0 0 0 0 0 0 11 13A4as 0.143 a 4.00 2M 56 35 142 90 0 0 0 0 IA-dw 1270 a 35.66 87.06 0 0 0 0 0 0 0 0 L•--D 11DO 0390 a 1032 11.31 21 21 229 238 0 0 0 0 W 13A4ors 0.143 se 4A0 Z55 0 0 0 0 0 0 0 0 V� 1344ots 0.143 s 4.00 2.55 0 0 0 0 66 56 226 144 I---G 1A-c1am 1270 s 35.66 34.77 0 0 0 0 0 0 0 0 �1 13A 4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 I--G IA-d m 1270 w 3556 54.53 0 0 0 0 0 0 0 0 LI---GG IA-ctom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5-20m 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-0sv OD91 - 255 128 113 113 287 145 66 66 168 94 C 16A30md 0.032 - 0.90 2.32 92 92 82 213 42 42 38 97 F 22A-1pl 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 6 c)AEDemiiraw 49 -24 Envelope loslgain 7239 637 791 301 12 a) InSltiafion 107 30 107 30 b) Roomventilation 0 0 0 0 13 Intemal gains: O=pan5@ 230 0 0 0 Appliancesbther 0 o 0 Subtotal(lines6to 13) 1346 667 898 331 Lessexemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redishibution 0 0 0 0 14 Subtotal 1346 667 898 331 15 Ductloads 29% 57°/ 387 379 29% 57% 258 188 Total mom load 1733 1041 1756 520 Air required(cirri) 72 47 48 23 Calculations approved byACCAto meet all requirements Of Manual J 8th Ed. -'I'-w�9h>bo>Z� 2021-JarF1213:18:18 �A - — Rgtt.Sufe@ kiwe W 201919.021 RSU08101 Page 5 ...DoarrerlslWdgltmft HVAC\WYNNE-THEWINDSORAP Calc=MJ8 FrorltDwrfams:N F}� wrightsoft° Right-J@ Worksheet Job: Entire House Dfit QUICK CALCS, INC. By. 317 ST..LUCIE LN.,Fr.PIERCE,FL 34946 Phwe:772466.6799 F.772-466-6796 Emil:OUICKCALCS(�AOL.COM 1 Room name GREArIDWING Room? 2 Elgwsdv4lll 50.0 ft 13D it 3 Room height 9.4 ft heaNmol 9.4 ft heatAwol 4 Room dimensions 1.0 z 567.0 ft 13.0 z 13D It 5 Room area 567.0 fF 169D R Ty Construc*on U-value Or HTM Area Load Am Load number (aluhfiF-°O (ewhm�) w perimeter (iq (awh) or penm�s (ft) (ewh) Heat Cool Gross N/P15 Heat Cool Gros NIPS Heat Cool 6 13A4= 0.143 n 4D0 255 282 244 978 622 122 107 429 273. IA-dom 12M n 3556 34.77 0 0 0 0 15 0 533 522 4A5,2om 0.770 n 2156 1931 38 0 815 730 0 0 0. 0 w 13AAocs 0.143 ne 4D0 255 0 0 0 0 0 0 0 0 11 W 13AA= - 0.143 a 4A0 255 0 0 0 0 - 0 0 0 0 �L---DG 1A-dom 1270 a 35M 87.06 0 0 0 0 0 0 - 0 0 11DO 0.390 a 10.92 —1131 0 0 0 0 0 0 0 -0 w 13AA= (1143 se 4D0 255 0 0 0 0 0 0 0 0 w - 13AA= 0.143 s 4A0 255 0 0 0 0 - 0 0 -0 - o L—G 1A-dom 1270- s - 3556 34.77 0 0 0 0 0 0 0- 0 13A4ocs 0.143 w 4.00 255 188 147 589 375 0 0 0 0 1AcIom 12M w 3556 54M 0 0 0 0 0 0 0 0 1A-dom 12M w 35M 54M 0 0 0 0 0 0 0 0 4A52om 0770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-Ow 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 0.90 232 567 567 506 1315 169 169 151 392 F 22A-Tyft 0" - 27.9 OAO 597 50 1385 0 169 13 -360 0 6 c)AED euaasion - 307 -100 Emebpe bWgain 5154 5210 1474 1086 12 a) Infiltration 889 251 231 65 b) Roomsentilation 0 0 0 0 13 bemal gairs Oovpam@ 230 0 0 1 230 Applianresober 0 0 Subbtal(linas(31o13) 6043 5461 1705 1311 Lesserlemal load 0 0 0 0 Lesshander 0 0 0 0 Redistribution 0 0 0 0 14 Subblal 6043 5461 1705 1381 15 Duct S 29% 57% 1737 3105 29% 57% 490 785 Total room bad 7780 8566 2195 2167 Airrequired(Qm) 325 386 92 98 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. -FW wr Oil 20214 1213:i8:18 A&k —^ MgttSUte@Lkiwrsa1201919.021RSU08101 Page ...Ooomenls\WnghbDRHVACIWYNNE-THEWIhDSORnp Calc=M1B FrortDoorlaces:N - + wrightsoft° Duct System Summary o : Entire House sY QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr.PIERCE,FL 34W Ptnre:772-66-6799 Fax T 2A66-6796 Email:DUICKCALCS@AOL.COM Project • For. WYNNE DEVELOPMENT THE WINDSOR,FT.PIERCE,FL Heating Cooling Extemal static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.00010.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 h1100ft Actual airflow 1160 cfm 1160 cfm Total effective length(TEL) 0 ft Supply Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cim) FR (in) (in) Mail Ln(ft) Ln(ft) Trunk BATH h 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM c 2788 119 126 0 0 Ox0 ShMt 0 0 BEOROOM2 h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM 2-A h 2587 117 117 0 0 OX0 ShMt 0 0 BEDROOM-A c 2788 119 126 0 0 0x0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox0 ShMt 0 0 GREATIDINING c 2855 108 129 0 0 0x0 ShMt 0 0 GREAT/DINING-A c 2855 108 129 0 0 Ox0 ShMt 0 0 GREAT/DINING-B c 2855 108 129 0 0 Ox 0 ShMt 0 0 KITCHEN c 725 31 33 0 0 Ox0 ShMt 0 0 LAUNDRY h 520 48 23 0 0 Ox0 ShMt 0 0 M.BATH h 811 49 37 0 0 0x0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 Rvom7 c 2167 92 98 0 0 OXO ShMt 0 0 WIC c 214 3 10 0 0 0x0 ShMt 0 0 Return Branch Detail Table Grille Htg Clg TEL Design Ueloc Diam HxW Stud/Joist Duct Name Size(in) (dm) (cim) (ft) FR (ipm) (in) (in) Opening(in) Mall Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 ShMt s -FP- Wrightsoft- 2021-Jarv1213d8:19 RlgItSute@Lhiversa120t9t9.021 RSU08101AM Paget ...Da its\WngftoftFNAQWYNNE-THEWINDSORrLp Calc=NW Frort Caorfams:N