Loading...
HomeMy WebLinkAboutFL-PR-SR600-TR700-01(RJW)-12x24-155C-5-13-21-Signed NOTES: UNINHABITED UTILITY SHED UP TO 12' WIDE x UP TO 24' LONG 1. BUILDING CODE: FLORIDA BUILDING CODE, 7th EDITION (2020) SR600, TR700, PR BUILDINGS ARE NOT FOR HIGH-VELOCITY HURRICANE ZONES (HVHZ) 2. DESIGN LOADING: OVERHANG OPTIONS REFER TO THE TRUSS DESIGN FOR WIND SPEED: Vint= 155 LUMBER SIZE, TRUSS SPACING Vasd— 120 AND PLATE SIZE TOE NAIL WITH(3) EXPOSURE: C �� 16d NAILS,(2)ONE ROOF LIVE LOAD: 20 PSF j COLLAR TIE REQUIRED ONLY AT SIDE,(1)OTHER ROOF DEAD LOAD: 10 PSF 12'WIDE SHEDS, SEE TRUSS CALCULATIONS SIDE FLOOR LIVE LOAD: MIN. 50 PSF (SEE NOTE 5, DETAIL 1, SHEET 3) 12 RAFTER RISK CATEGORY: 14 COMPONENT AND CLADDING: ROOF: 18/-29 PSF (ZONE 1) FLORIDA APPROVED WIND PRESSURE (psf) (ASD VALUES) 18/-50 PSF (ZONE 2) SHINGLES (BASED ON 10 SQ FT) 18/-74 PSF (ZONE 3) WALL: 31/-34 PSF (ZONE 4) 31/42 PSF (ZONE 5) Q H SIMPSON H2.5A PLATE ON g X \ SEE THE TRUSS INSIDE AT EACH RAFTER w —CONNECTION J DETAIL- DETAIL 2 WALL TOP PLATES SHED MANUFACTURER SHALL HAVE A LIST OF ALL REQUIRED o0 J WALL FRAMING TO BE PRODUCTS THAT NEED FLORIDA STATE APPROVAL AVAILABLE FOR C° < 2x4 SPF#2 OR BETTER SIDING 3RD PARTY INSPECTOR AND REVIEW BY E.O.R. FOR COMPLIANCE SEE SHEET 3 FOR STEEL FLOOR WITH @ 16" O.C. WITH WIND LOADS. ANCHOR DETAIL OR FOUNDATION DETAIL IF BUILDING IS LOCATED STUDS IN A FLOOD ZONE THEN _ UP TO 12'WIDE _ FLOOD VENTS AND PRESSURE TREATED STUDS ARE REQUIRED- HEADER NAILING: O TRUSS TO WALL HEADER TO STUD- 4-16d END NAIL DOUBLED HEADER ONE SQ INCH VENT 2 CONNECTION DETAIL - 16d @ 16 STAGGERED FACE NAIL O BUILDING SECTION FOR EVERY ONE SQ FT SCALE:N.T.S. SCALE N.T.S OF BUILDING NAILING: CRIPPLE STUD REFER TO SHEET 2 FOR WALL AND ROOF SHEATHING NAILING. DOUBLE TOP PLATE KING STUD MAX WALL HEIGHT FOR EACH SHED: --- CRIPPLES (IF REQ.) DOUBLE TOP PLATE SR600-5-8 1/4" (68 1/4") HEADERS FOR CRIPPLES (IF REQ.) TR700-6'-8 1/4" (80 1/4") OPENINGS UP TO 4'-0" — HEADERS FOR PR-6-8 1/4" (80 1/4") USE (2)2x4 SPF#2 OPENINGSUSE 2x4 SPFOZ'-0" OPENINGS 4'-1"TO 6'-0" USE (2)2x6 SPF#2 OPENINGS 6-1"TO 8'-0" 2x4 WINDOW SILL USE (2)2x8 SPF#2 FLOOR DECKING TRNG IMMER MMERD LTRIMMER STUD HEADERS FOR: BASE PLATE BASE PLATE OPENINGS UP TO 6'-0" USE (2)2x4 SPF#2 KING STUD OPENINGS 6'-1"TO 8'-0" USE (2)2X6 SPF#2 FLOOR DECKING REFER TO THE DOOR DETAIL(SHEET 2)FOR FOR WINDOW OPENINGS UP TO 4'-01, FOR OPENINGS UP TO 8'-0' THE DOOR DESIGN 4 WINDOW HEADER DETAIL DOOR HEADER DETAIL HEADER DETAIL FOR FOR SIDE WALLS 36 FOR SIDE WALLS 4 END WALLS SCALE: N.T.S. SCALE: N.T.S. SCALE'. N.T.S. Order#. P.O.# THESE DRAWINGS AND THE TUFF SHED,INC. TITLE DRAWING NO. This item has been digitally signed and sealed by TUFF SHED DESIGN ARE THE PROPERTY Richard Wills PE on the date adjacent to the seal o E N SF�s Customer: Drawn By: PK OF TUFF SHED, INC. THESE ENGINEERING DEPARTMENT FL-PR-SR-TR-01 � Na/sags DRAWINGS ARE FORA BUILDING SECTIONS Printed copies of this document are not considered �* 6 Date: 3/12/19 BUILDING TO BE SUPPLIED signed and sealed and the signature must be Storage Buildings & Garages RICHARD J.WILLS,P.E. REV. LEVEL 01 verified on any electronic copies. Site Address: AND BUILT BY TUFF SHED. HEADER FRAMING DETAILS � p-. STATE oc Q TUFF SHED, MFG. FACILITIES RWILLS@TUFFSHED.COM °�•�4oaioP Checked By: ANY OTHER USE IS 1777 S. HARRISON STREET SHEET FORBIDDEN BY BOTH TUFF FBC, 7th EDITION (2020) q/rrrrrriiitttt�tv�� Date: SHED AND THE ENGINEER OF DENVER,COLORADO 80210 Building Size:WIDTH-LENGTH-HEIGHT-SQ.FT.AREA RECORD (303)753-8833 EXT. 96315 155C Scale: N.T.S. PAGE 1 OF 4 13 MAY 2021 3/8 SMART SIDE NAILING REQUIREMENTS USE THESE NAILING TABLES FOR THE SR600, TR700 AND PR DRAWINGS SIDE WALL EDGE NAILING REQUIREMENTS END WALL EDGE NAILING REQUIREMENTS MARK MAX. MARK WALLS END SIDE COMB. MIN TOTAL WALLS END SIDE MAX. MIN TOTAL BEING WALL WALL OPENING COMBINED BEING WALL WALL COMB. COMBINED USED WIDTH LENGTH EDGE NAILING (NOTE 2) SHEAR WALL USED WIDTH LENGTH EDGE NAILING OPENING SHEAR WALL NO OPENINGS ALONG THE WALL NO OPENINGS ALONG THE WALL 6' 6'-20' 8d NAILS @ 6"O.C. 0' 6'-18' 6' 6'-10' 8d NAILS @ 6"O.C. 0' 6' 8' 8'-24' 8d NAILS @ 6"O.C. 0' 8'-24' 6' 12'-14, 8d NAILS @ 4"O.C. 0' 6' 10, 10'-24' 8d NAILS @ 6"O.C. 0' 10'-24' 6' 16'-20' 8d NAILS @ 3"O.C. 0' 6' 12' 12'-24' 8d NAILS @ 6" O.C. 0' 12'-24' 8' 8'-12' 8d NAILS @ 6" O.C. 0' 8' ■MIN 2'-0" RTN WALLS ON EACH END OF WALL- ■MIN 2'-0"WALL SEGMENT 8' 14'-20' 8d NAILS @ 4"O.C. 0' 8' 6' 6'-20' 8d NAILS @ 6"O.C. UP TO 12' 4' 8' 22'-24' 8d NAILS @ 3"O.C. 0' 8' 8' 8'-24' 8d NAILS @ 6"O.C. UP TO 12' 4' 10, 10'-16' 8d NAILS @ 6"O.C. 0' 10, 10, 10'-24, 8d NAILS @ 6"O.C. UP TO 12' 7' 10, 18'-24' 8d NAILS @ 4"O.C. 0' 10, 10, 10'-24, 8d NAILS @ 4"O.C. UP TO 12' 4' 12' 12'-18' 8d NAILS @ 6"O.C. 0' 12' 12' 12'-24' 8d NAILS @ 6"O.C. UP TO 12' 8' 12' 20'-24' 8d NAILS @ 4" O.C. 0' 12' 12' 1 12'-24' 18d NAILS @ 4"O.C. UP TO 12' 6' 12' 1 12'-24' 18d NAILS @ 3"O.C. UP TO 12' 4' ■MIN 2'-0" RTN WALLS ON EACH END OF WALL- ■MIN 2'-0"WALL SEGMENT 6' 6-9' 8d NAILS @ 6" O.C. 3' SEE NOTE 3 6' 10, 8d NAILS @ 3"O.C. (BS) 3' 2' RE: NOTE 6 ROOF SHEATHING (7/16"OSB) 8' 8' 8d NAILS @ 6"O.C. 3' 5' WIDTH LENGTH FIELD NAILING EDGE NAILING 8' 10'-12' 8d NAILS 4"O.C. 3' 5' 6' 6'-18' 8d NAILS @ 12" O.0 8d NAILS @ 4" O.C. 8' 14'-16' 8d NAILS @ 3"O.C. 3' 5' 8' 8'-24' 8d NAILS @ 12" O.0 8d NAILS @ 4" O.C. 8' 1 18'-24' 8d NAILS @ 4"O.C. (BS) 3' 5' 10, 10'-24, 8d NAILS @ 12" O.0 8d NAILS @ 4" O.C. 8' 8' 8d NAILS @ 6"O.C. 4' 4' 12' 12'-24' 8d NAILS @ 12"O.0 8d NAILS @ 4" O.C. 8' 10' 8d NAILS @ 3"O.C. 4' 41 8' 12'-22' 8d NAILS @ 3"O.C. (BS) 4' 4' NOTES: 10, 10' 8d NAILS 6"O.C. 3' 7' 1. USE 8d COMMON OR GALVANIZED BOX NAILS. 10, 12'-16' 8d NAILS @ 4"O.C. 3' 7' 10, 18' 8d NAILS @ 3" O.C. 3' 7' 10, 20'-24' 8d NAILS @ 4"O.C. BS 3' 7' 10, 10'-14' 8d NAILS @ 4"O.C. 4' 6' TABLE NOTES: 10, 16' 8d NAILS @ 3"O.C. 4' 6' 1. NAILING IS FOR 3/8" SMARTSIDE PANEL OR 3/8"SMARTSIDE 10' 18'-24' 8d NAILS 4"O.C. BS 4' 6' WITH FOIL BACKER. 10, 10' 8d NAILS 3"O.C. 6' 4' 2. NO SINGLE OPENING GREATER THAN 8'-0" 10, 12'-24' 8d NAILS @ 3"O.C. (BS) 6' 4' 3. *6'WIDE X 6'-9' LENGTH BUILDINGS ARE BASED ON 3-SIDED 12' 12' 8d NAILS @ 6" O.C. 4' 8' DIAPHRAGM. THE END WALL OPPOSITE OF THE OPENING MUST 12' 14'-18' 8d NAILS @ 4"O.C. 4' 8' BE FULLY SHEATHED, IN THE 3-SIDED DIAPHRAGM CASES. THE 12' 20'-24' 8d NAILS @ 3"O.C. 4' 8' END WALL WITH THE OPENING DOES NOT HAVE A MIN. RETURN 12' 12'-14' 6' 6' WALL ON EACH SIDE OF THE OPENING. 4. USE COMMON OR GALVANIZED BOX NAILS. 12' 16'-18' 6' 6' 5. FIELD NAILING FOR 3/8" SMARTSIDE: 8d @ 12"O.C. 1 12' 1 20'-24' 18d NAILS @ 4"O.C. (BS) 6' 6' 6. ON THESE BUILDINGS 6'X 10'-18'THE T DOOR IN THE END WALL 12' 12'-14' 8d NAILS 3"O.C. 8' 4' WILL NEED TO BE OFF SET. THERE WILL BE A 2' PANEL ON ONE 12' 16'-24' 8d NAILS a 3"O.C. BS 8' 4' SIDE AND A 1' PANEL ON THE OTHER SIDE OF THE DOOR. 7. (BS)- DESIGNATES WALLS THAT NEED TO BE SHEATHED ON BOTH SIDES. THESE DRAWINGS AND THE This item has been digitally signed and sealed by Order#. P.O.# TITLE DRAWING NO. TUFF SHED DESIGN ARE THE PROPERTY TUFF SHED,INC. ENS•.,( ENGINEERING DEPARTMENT FL-PR-SR-TR-01 Richard Wills,PE.on the date adjacent to the seal. Customer: Drawn By: PK OF TUFF SHED, INC. THESE N..75835 DRAWINGS ARE FORA DOOR DETAILS Printed copies of this document are not considered -*c Storage Buildings & Garages Date: 3/12/19 BUILDING TO BE SUPPLIED RICHARD J.WILLS,P.E. REV. LEVEL 01 signed and sealed and the signature must be verified on any electronic copies. Site Address: AND BUILT BY TUFF SHED. NAILING REQUIREMENTS 9, STATE OF Q TUFF SHED, MFG. FACILITIES RWILLS@TUFFSHED.COM i��•''4... Checked By: ANY OTHER USE Is 1777 S. HARRISON STREET FBC, 7th EDITION 2020 SHEET FORBIDDEN BY BOTH TUFF ( ) �NlfttllVttttt Date: Building Size:WIoTH-LENGTH-HEIGHT-SQ.FT.AREA SHED AND THE ENGINEER OF DENVER,COLORADO 80210RECORD. (303)753-8833 EXT.96315 155C Scale: N.T.S. PAGE 2 OF 4 13 MAY 2021 #12-14 X 3" HEX HEAD t TRIM SELF-DRILLING SCREWS ► 1. STEEL SHED FOUNDATION: AUGER ANCHOR COMPONENTS BY OLIVER TECHNOLOGIES 2X4X2� 600T125-054- 16 GAUGE STEEL TRACKS G140 ZINC COATED SIDING . PART NUMBERS: ' 3/4"APA OR TECO RATED 600S137-054- 16 GAUGE STEEL JOISTS G140 ZINC COATED BLOCK OT3644GPMP-5/8"X 36"(36" IMBED)GALVANIZED AUGER T&G FLOOR DECKING. @ 24" O.C. ATTACH BRACKET TO OT17SWB-SIDEWALL BRACKET FOR USE WITH THRU BOLTS 2X6 STEEL JOISTS (SUPPLIER: ALLIED STUDCO (JOIST: 60OS137-054/TRACK: STUD THRU HOLE IN REPORT NO. LO-FJ90129-A @ 24"OC 600T125-054) ICC ER-4943P. ANCHOR PLATE WITH -OR- t ® 2. 3/4"APA OR TECO RATED TONGUE AND GROOVE FLOOR z_ 3/8"0 x 4"CARRIAGE OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS #10 X 3/4" PAN t r DECKING. 24" MAX PANEL SPAN. STAGGER PANEL LAYOUT. BOLT AND LOCKNUT REPORT NO. LO-FJ90129-B HEAD SELF-DRILLING ®•. 3 FASTEN FLOOR DECKING TO JOIST&TRACKS USING 'v • WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS . SCREWS (2 PER TAB) ® CORNER STUD •= #8 x 1-5/8"ZINC PLATED SCREWS @ 12"O.C. WITH THE MAXIMUM LOAD OF 5,080 LBS VENT HOLES @ 24"OC. — NO BLOCKING REQUIRED. ALL EDGES SHALL LIE ON FLOOR JOISTS. STAGGER PANEL LAYOUT PER APA CONDITION 1. OPTIONAL LEVELING BLOCKS 4. FASTEN SOLE PLATE THROUGH FLOOR DECKING INTO JOISTS /i //i//i//i//i//i//i ////// AUGER ANCHORS 2X6 STEEL TRACK EACH END OR TRACKS WITH #12-14 X 3" GALVANIZED SELF-DRILLING \// /�//i�/X­////// ///i�// STUD- Q WIDTH LENGTH #OF ANCHORS i SCREWS. REFERENCE SPACING CHART. ///�///�///////// W 6' 6'-18' 4 ANCHORS BASE PLATE SCREW SPACING i 5. ALLOWABLE FLOOR LIVE LOAD: 75 PSF FOR STEEL JOISTS 8' 8'-24' 4 ANCHORS WIDTH SPACING CONTINUOUSLY SUPPORTED. 50 PSF FOR JOISTS ON BLOCKS to 10, 10'-24' 6 ANCHORS 6'-12' 8"O.C. AS SHOWN. STUD 12' 12'-24' 6 ANCHORS 6. USE OPTIONAL CONCRETE BLOCKS AS REQUIRED TO LEVEL 4-ANCHORS PROVIDE (1)AT EA. BUILDING: SIDING CORNER OF THE BUILDING. SUGGESTED SIZES: 2"x 8"x 16", 4"x 8"x 16", OR 8"x 8"x 16". 6-ANCHORS PROVIDE (1)AT EA. OSTEEL SHED BASE DETAIL BLOCKS UNDER JOISTS SPACED @ 8'-0"O.C. MAXIMUM. _ TRIM CORNERS OF THE BUILDING AND (1)AT 1 ' " END WALL THE CENTER OF EA. SIDE WALL. SCALE: N.T.S. BLOCKS UNDER TRACK SPACED @ 4-0 O.C. MAXIMUM. I` 7 ANCHOR BRACKET TO BE FLUSH WITH OAUGER ANCHOR DETAIL EDGE OF TRIM SCALE: N.T.S. UNHEATED SPACE SIDING STUD KWIK BOLT ANCHORS (INTO CONCRETE) ANCHOR BOLT& CONTINUOUS FOOTING NOTES TRIM RE: DETAIL 3 SHEET 3 P.T. SILL PLATE 1. TOP OF SLAB TO BE 6"MIN.ABOVE GRADE. SLAB REINFORCEMENT SHALL 3/8" NYLON WIDTH LENGTH QTY PER NOTES BELOW BE WWF 6X6 W1.4xW1.4. LOCATE AT MID-DEPTH OF SLAB. -OR- 3/8" CARRIAGE LOCK NUT 6' 6'-10' 6 #4 CONTINUOUS SLAB REINFORCEMENT SHALL BE FIBERMESH 150 OR BLENDED FIBERMESH150. FIBERMESH SHOULD BE DISPERSED UNIFORMLY BOLT(GRADE 2) 6' 8'-14'' 8 TOP&BOTTOM THROUGH CONCRETE W/MIN.1 POUND PER CUBIC YARD OF CONCRETE. z BASEPLATE 8' 8'-14' 6 _J 0- 1 3/4' 2. ALL FOOTING FORMS SHALL BE INSPECTED FOR SIZE AND REINFORCING 8' 16'-20' 8 U FINISH CONCRETE FLOOR BEFORE POURING CONCRETE. FLOOR PLY 8' 22'-24' 10 M ~ GRADE 3. FOOTINGS SHALL BEAR ON UNDISTURBED NATURAL,COMPETENT SOIL, OT17SWB 411 OR PROPERLY COMPACTED STRUCTURAL FILL. ALLOWABLE SOIL 10' 10'-16' rr 6 BEARING PRESSURE IS 1000 PSF AT 12"BELOW GRADE. -OR- — 4. CONCRETE:MINIMUM 28 DAY COMPRESSIVE STRENGTH,Pc=2500 PSI. 10' 18'-24' 8 � z � ---�—.--- ---- 'v OT24SWB A 5. REINFORCING STEEL:A615,GRADE 40 OR GRADE 60. ALL REINFORCING 12' 12'-18' 6 j�j/� � STEEL SHOWN TO BE CONTINUOUS MAY BE LAPPED A MINIMUM OF 38 BAR 6„ O 12' 20'-24' 8 4 \� \� �' DIAMETERS OR 24"MINIMUM,WHICHEVER IS LARGER. "� Z /������� a 6. SA. CATEGORY:ATTACH PR RE TREATED SOLE PLATE TO THE FOOTING USING 1/2 HILTI KWIK BOLT TZ NOTES: + // �i� / SLAB 1/2"DIA X 8"LONG SIMPSON TITEN HD ANCHOR WITH WASHERS. STAINLESS STEEL 304 1.ANCHORS TO BE KWIK BOLT TZ, 304 SS B. EXPANSION BOLTS SHALL BE EMBEDDED AT LEAST 5"INTO THE EMBEDMENT DEPTH = 2 1/4" 3" CLR. \�j REINFORCEMENT CONCRETE AND SHALL BE SPACED NOT MORE THAN 6'OC. — STEEL SHED „ 2. PROVIDE (1)ANCHOR AT EA. CORNER � � TYP. PER NOTES BELOW C. THERE SHALL BE A MINIMUM OF 2 BOLTS PER SOLE PLATE PIECE MIN. EDGE DISTANCE = 6 BASE OF THE BUILDING. THE REMAINING C) >_ 8" WITH 1 BOLT LOCATED NOT MORE THAN 12"NOR LESS THAN 7 BOLT ANCHOR SPACING: RE: KWIK 6" CONCRETE ANCHORS EQUALLY SPACED ALONG THE ' 1- DIAMETERS FROM EACH END OF EACH PIECE. BOLT ANCHORS TABLE, SHEET 3 PAD (MIN) LENGTH OF THE BUILDING. (1/2 THE `Y' MIN. THICKENED SLAB REMAINING ANCHORS ). EA. LENGTH SIDE EQUALLY SPACED). (D4 CONCRETE FOUNDATION DETAIL OSIDEWALL BRACKET DETAIL SCALE:N.T.S. 3 SCALE N.T.S. THESE DRAWINGS AND THE Order#. P.O.# TUFF SHED,INC. TITLE DRAWING NO. This item has been digitally signed and sealed by �GNA••-•V." TUFF SHE D DESIGN ARE THE PROPERTY \` G E NS �S ENGINEERING DEPARTMENT FL-PR-SR-TR-01 Richard Wills,PE.on the date adjacent to the seal. P •. Customer: Drawn By: PK OF TUFF SHED,INC. THESE No.7663E DETAILS Printed copies of this document are not considered -* DRAWINGS ARE FOR A P — Storage Buildings & Garages Date: 3/12/19 BUILDING TO BE SUPPLIED RICHARD J.WILLS,P.E. REV. LEVEL 01 signed and sealed led and the signature must be o. Site Address: verified on an electronic copies. STATE OF AND BUILT BY TUFF SHED. %moo •F4 At oP TUFF SHED, MFG. FACILITIES RWILLS@TUFFSHED.COM Checked By: ANY OTHER USE IS SHEET �''�i,`csS;;..••-••."G`����° 1777 S. HARRISON STREET FBC, 7th EDITION 2020 3 iii, oNAL 10 FORBIDDEN BY BOTH TUFF ( ) rprrtllllVllt��� Date: Building Size:WICTN-LENGTH-HEIGHT-SQ.FT.AREA SHED AND THE ENGINEER OF DENVER,COLORADO 80210RECORD (303)753-8833 EXT. 96315 155C Scale: N.T.S. PAGE 3 OF 4 13 MAY 2021 3X4 20 GA PLATE: 6'SPAN 8'SPAN 3X4 20 PLATES 1 EACH SIDE REACTIONS: REACTIONS: 3'-0" 1 EACH SIDE MAX. VERTICAL: 180 LBS. MAX. VERTICAL: 240 LBS. 3;1,/8„ 5-0 S.3 1/16„ MAX. UPLIFT: -160 LBS. MAX. UPLIFT: -195 LBS. 12 12 NOTE: NOTE: Q4 Q4 TRUSS MAY BE USED ON BUILDING LENGTHS TRUSS MAY BE USED ON BUILDING LENGTHS 0 1 18.0° UP TO 12FT UNLESS CEILING JOIST OR OTHER UP TO 14FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED. TENSION TIE IS PROVIDED. 00 f LO 6'-0" 00 10'-0" 10' SPAN 12'SPAN N 'L�5 REACTIONS: REACTIONS: "' MAX. VERTICAL: 300 LBS. MAX. VERTICAL: 390 LBS. MAX. UPLIFT: -250 LBS. MAX. UPLIFT: -285 LBS. 3X4 20 GA PLATES 00 3X4 20 PLATES / 1 EACH SIDE NOTE: NOTE: 00 c 1 EACH SIDE _ 6 0 _ TRUSS MAY BE USED ON BUILDING LENGTHS TRUSS MAY BE USED ON BUILDING LENGTHS `'? 4'-0" I 6 '3 11/16„ UP TO 20FT UNLESS CEILING JOIST OR OTHER UP TO 24FT UNLESS CEILING JOIST OR OTHER 4'2 1/2 12 TENSION TIE IS PROVIDED. TENSION TIE IS PROVIDED. 12 Q 4 1 � Q 4 � 1 ° 3X6 20 GA° PLATES MAXIMUM DEFLECTION (12 FT. SPAN) 1 EACH SIDE VERT LL: 0.06 in. 8'-0" VERT TL: 0.08 in. 00 to N 6'-0 N ROOF UNDERLAYMENT SEE PROJECT NOTES FOR MATERIALS PER FBC 1507.1.1.1(3). 12'-0" MINIMUM 3 3/4"STRIP OF NAIL TO INTERMEDIATE FRAMING SELF ADHERING FLEXIBLE 4'x8'x7/16"ROOF MEMBERS-REFERENCE NAILING FLASHING TAPE COMPLYING SHEATHING SCHEDULE,SHEET 2 DESIGN LOADS: ALL PERSONS FABRICATING, HANDLING, ERECTING OR INSTALLING THIS TRUSS ARE TO DO SO IN WITH A LEVEL 3, INSTALLEDD IN ACCCC ORDANCE DIAPHRAGM TOP CHORD LIVE LOAD =20 PSF ACCORDANCE TO THE RECOMMENDATIONS OF THE LATEST VERSION OF THE BCSI. TO MANUFACTURER'S BOUNDARY TOP CHORD DEAD LOAD = 10 PSF INSTRUCTIONS FOR THE TRIM COLLAR TIE DEAD LOAD =5 PSF DECK MATERIAL FL PRODUCT APPROVAL NOTES: NUMBER FL10626 FBC, 7th EDITION (2020) PANEL EDGE IS NOT ANSI/TPI 1-2014 SUPPORTED BY BLOCKING- TRUSSES TO BE SPACED @ 24"OC DRIP EDGE UNLESS NOTED MATERIAL TO BE 2X4 SPRUCE PINE FIR GRADE#2 OR BETTER PLATES ARE TO BE PRESSED IN THE WOOD PER TPI. REP MEMBER INCREASE:YES REFERENCE NAILING RAFTERS AND/ SIDING LUMBER D.O.L.: 1.25 SCHEDULE/S2 OR TRUSSES O ROOF SHEATHING AND WIND: UNDERLAYMENT DETAIL ASCE 7-16, 155 mph, Exposure C, D.O.L.=1.60 SCALE N.T S. PLATES ARE MANUFACTURED BY EAGLE METAL PRODUCTS, ICC-ES#ESR-1082. Order#. P.O.# THESE DRAWINGS AND THE TITLE DRAWING NO. �\���"`NpRD'w7j7j�i TUFF SHED TUFF SHED,INC. This item has been digitally signed and sealed by DESIGN ARE THE PROPERTY Q;•� C E NS'•.�s�i Richard Wills,PE.on the date adjacent to the seal. F •. Customer: Drawn By: PK OF TUFF SHED,INC. THESE ENGINEERING DEPARTMENT FL-PR-SR-TR-01 No.76835 o TRUSS DETAILS Printed copies of this document are not considered -* DRAWINGS ARE FOR P •' Storage Buildings & Garages Date: 3/12/19 BUILDING TO BE SUPPLIED RICHARD J.WILLS,P.E. REV. LEVEL 01 signed and sealed and the signature must be * *` Site Address: AND BUILT BY TUFF SHED. verified on an electronic copies. STnTE OF TUFF SHED, MFG. FACILITIES RWILLS@TUFFSHED.COM '9 Q Checked By: ANY OTHER USE IS <•Oq:OP•,\���'\���� 1777 S. HARRISON STREET FBC, 7th EDITION 2020 SHEET ^ �ii773�oNAiFEN������` 8524 EAST COLONIAL DRIVE FORBIDDEN BY BOTH TUFF ( ) L} ORLANDO,FL32817 Building Size:WIDTH-LENGTH-HEIGHT-SG.FT.AREA Date. SHED AND THE ENGINEER OF DENVER,COLORADO 80210 (888j 788-TUFF RECORD (303)753-8833 EXT. 96315 155C STORE520 Scale: N.T.S. PAGE 4 OF 4 13 MAY 2021