Certification for Design Load Compliance
7th Edition
Project Name: SCOTT BUDNIK
Project Address: 8401 S. INDIAN RIVER DRIVE, FT. PIERCE, FL 34982
Permit #:
INSTRUCTIONS FOR USE:
Occupancy Type: R-3 Construction Type:5-B
• This certification must be completed, signed, and sealed by the design professional of record.
• If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally
signed electronic version.
• If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required
• All digital files must be in an unlocked Portable Document Format (PDF) version
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2020 Code 7th Edition using ASCE 7-16
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: 1 II X III IV Exposure Category: B C X D
4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: 6.0 ft
5. Mean Roof Height 18 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used:
Zone 4: Zone 5: Garage: +41.7/-52.0
6a. Roofs
Maximum +/- pressures: + psf - psf Or define individual zones on the plans
7. Design Loads: Floor: 2500 PSF Roof -Dead: 25 PSF Roof -Live: 30 Balcony+/- N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain:
9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes No Assumed
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the current Florida Building Code as adopted.
Digitally signed by Lillian Gonzalez
Date: 2021.07.0113:10:20-04'00� Lillian Gonzalez 79442 & 32045
Signature, Date, and Seal _Print Name Cert # & Co. CertofAuthorization
Goarch Engineering, Inc 1824 Richard Ln WPB, FL 33406
Revised 3/25/2021
Company Name & Address