Loading...
HomeMy WebLinkAboutBUDNIK WindLoadCertification7thEd_sealed(1)Planning & Development Services Department } Building & Code Regulations Division �,# 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1577 Certification for Design Load Compliance 7th Edition Project Name: SCOTT BUDNIK Project Address: 8401 S. INDIAN RIVER DRIVE, FT. PIERCE, FL 34982 Permit #: INSTRUCTIONS FOR USE: Occupancy Type: R-3 Construction Type:5-B • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2020 Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: 1 II X III IV Exposure Category: B C X D 4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: 6.0 ft 5. Mean Roof Height 18 ft Roof Pitch: 5 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: Zone 4: Zone 5: Garage: +41.7/-52.0 6a. Roofs Maximum +/- pressures: + psf - psf Or define individual zones on the plans 7. Design Loads: Floor: 2500 PSF Roof -Dead: 25 PSF Roof -Live: 30 Balcony+/- N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain: 9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the current Florida Building Code as adopted. Digitally signed by Lillian Gonzalez Date: 2021.07.0113:10:20-04'00� Lillian Gonzalez 79442 & 32045 Signature, Date, and Seal _Print Name Cert # & Co. CertofAuthorization Goarch Engineering, Inc 1824 Richard Ln WPB, FL 33406 Revised 3/25/2021 Company Name & Address