HomeMy WebLinkAboutAPPROVED, TARCO ROOF UNDERLAYMENTNEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION Tarco Roofing Evaluation Report 10880.07.08-1114 One Information Way, Suite 225 F1.10450-1114 Little Rock, AR 72202 Date of Issuance: 07/11/2008 (254) 913-7750 Revision 14: 03/22/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. QESCRIPTION: Tarco Roof Underlayments for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Evaluation Report consists of pages 1 through 11. Prepared by: Robert J.M. Nieminen, P.E. PE = a's"" r �. _ sr•;^The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 ,• ks/ -• E, ,q' Nleminen, P.E. on 03/22/2021. This does not serve as an '��•n i nn"'electronically signed document. CERTIFICATION OF INDEPENDENCE: I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018, NEMO ETC, LLC ONEMOletc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Tarco Roof Underlayments, as produced by Tarco Roofing, have demonstrated compliance with the following sections of the 711 Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1507.1.1 / R905.1.1 Material standard ASTM D226 2009 1507.1.1 / R905,1.1 Material standard ASTM D4869 2016 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, Material standard ASTM D1970 2015 R905.2.8.2 1507.2.9.2, 1507.6.5 / R905.2.8.2, R905.5.4 Material standard ASTM D3909 2014 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / Tear strength ASTM D4533 2015 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / Tensile strength ASTM D5035 2011 R905,1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.2.9.2, 1507.6.5 / R905.2.8.2, R90S.5.4 Material standard ASTM D6380 2013 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 1507,11.2 / R905.11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: intfty Examination Reference Date Entity Examination Reference Date ERD (TST6049) D4869,D5035 C30280.12.09 12/11/2009 PRI (TST5878) ASTM D226 TOT-014-02-02 05/18/2004 ERD (TST6049) FRSA/TRI T33190.08.10 08/06/2010 PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004 ERD (TST6049) ASTM D1970 T32530.08.10 08/17/2010 PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004 ERD (TST6049) ASTM D4798 C30280.12.09-R2 08/20/2010 PRI(TSTS878) ASTM D4869 TOT-009-02-02 09/14/2004 ERD (TST6049) FM 4474 T37610.07.11 06/29/2011 PRI (TST5878) ASTM D226 TOT-041-02-01 05/24/2006 ERD (TST6049) ASTM D3909 T40780.04.12 04/06/2012 M-D(CER1592) FBC HVHZ 16-1116.09 01/12/2017 ERD (TST6049) ASTM D6380 T40790.04.12 04/06/2012 NEMO FBC Cross -List Listing Agreement 01/20/2020 ERD (TST6049) ASTM D6164 T35410.04.12 04/18/2012 NEMO FBC Cross -List 2 Listing Agreement 2 03/22/2021 ERD (TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 NEMO (TST6049) FRSA/TRI TAR-SC8020.06.18 06/05/2018 ERD (TST6049) FRSA/TRI T43930.09.13-R2 09/11/2013 NEMO (TST6049) Tensile adhesion 4S-TAR-18-002.07.18-1 07/20/2018 ERD (TST6049) D226 & D4869 SC4950.02.14-R2 06/25/2014 NEMO (TST6049) FRSA/TRI 4S-TAR-18-002.07.18-2 07/20/2018 ERD (TST6049) ASTM D1970 TAR-SC9480.15 07/02/2015 NEMO (TST6049) TAS 117(B) 4i-CTR-I9-SSCRT-01.A 04/10/2019 ERD (TST6049) FM 4474 TAR-SC8020.14 12/03/2015 NEMO (TST6049) ASTM D4798 4i-TAR-I9-SSUDL.01.A 08/27/2019 ERD (TST6049) FM 4474 TAR-SC5670.03.16 03/21/2016 NEMO (TST6049) ASTM D1970 4j-TAR-20-SSUDL-02.A 02/08/2021 ERD (TST6049) FM 4474 T6460.06.07-R2 05/26/2017 NEMO (TST6049) ASTM D5035 4j-TAR-20-SSUDL-02.A 02/22/2021 ERD (TST6049) ASTM D226 TAR-SC13965.02.17-Ri 05/17/2017 NEMO (TST6049) ASTM D1623/D4798 4j-TAR-20-SSUDL-03 03/15/2021 ERD (TST6049) FBC 1507.1.1 TAR-SC16115.17 10/02/2017 Tarco Roofing Adhesive comp Affidavit 12/15/2015 ERD (TST6049) FRSA/TRI TAR-SC16115.17 10/02/2017 UL, LLC. (QUA9625) QA Service Confirm (IND) 11/22/2016 ERD (TST6049) ASTM D4533 CTR-SC16080.10.17 10/25/2017 UL, LLC. (QUA9625) CIA Service Confirm (PA) 06/28/2017 PRI (TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 UL, LLC. (QUA9625) QA Service Confirm (TX) 08/13/2018 PRI (TST5878) ASTM D1970 BRY-017-02-01 08/11/2003 UL, LLC. (QUA9625) CA Florida BCIS Current NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certlf sate ofAuthorizatfon #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10450-R14 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 2 of 11 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 #ONEmoletc. PRODUCT Product Material Standard Plant(s) Description LeakBarrier° MS300 Ice and ASTM D1970 Belton, TX self -adhering, glass mat reinforced, mineral Water Armor Greencastle, PA surfaced, SBS modified roof underlayment SRS Distribution TopShield ASTM D1970 Belton, TX self -adhering, glass mat reinforced, mineral Ice & Water G300 Greencastle, PA surfaced, SBS modified roof underlayment LeakBarrier PS200HT Ice and ASTM D1970 and Belton, TX self -adhering, glass mat reinforced, fabric Water Armor FRSA/TRI 09-18 Greencastle, PA surfaced, SBS modified roof underlayment LeakBarrier° PS200mu Ice ASTM D1970 Belton, TX self -adhering, glass mat reinforced, smooth and Water Armor Greencastle, PA poly film surfaced, SBS modified roof underlayment LeakBarrier° NR600 Ultra Ice ASTM D1970 and Greencastle, PA self -adhering, polyester -fabric surfaced, SBS and Water Armor FRSA/TRI 09-18 modified roof underlayment LeakBarrier° SS400 Ice and ASTM D1970 Belton, TX self -adhering, fiberglass reinforced, smooth Water Armor Greencastle, PA surfaced modified underlayment Tarco 30 ASTM D226, Type II Belton, TX asphalt -saturated organic felt Greencastle, PA LeakBarrier° EasyLay" ASTM D226, Type II Belton, TX asphalt -coated polyester fabric roof Greencastle, PA underlayment Fiberglass Mineral Surfaced ASTM D3909 Greencastle, PA glass -fiber -reinforced, asphalt -coated, granule Roll Roofing surfaced underlayment used as a valley liner ASTM Organic Mineral ASTM D6380, Class M Greencastle, PA asphalt -saturated organic roll roofing sheet Surface Tile Underlayment LeakBarrier° EasyMopT" SBS FRSA/TRI April 09-18 Greencastle, PA polyester reinforced, SBS modified bitumen roofing underlayment LeakBarrier° Easylay' UDL 1507.1.1.1(2&3, Gujarat, India woven -polymeric scrim with a textured fabric 15 Exception), 1507.1.1.1(5) / on the top surface R905.1.1.1(2&3, Exception), R905.1.1.1(5) SRS Distribution TopShield® 1507.1.1.1(2&3, Gujarat, India woven -polymeric scrim with a textured fabric EL30 Exception), 1507.1.1.1(5) / on the top surface R905.1.1.1(2&3, Exception), R905.1.1.1(5) LeakBarrier° EasyLay® UDL 1507.1.1.1(2&3, Gujarat, India woven -polymeric scrim with a textured fabric 30 Exception), 1507.1.1.1(5) / on the top surface R905.1.1.1(2&3, Exception), R905.1.1.1(5) i F S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate of Authorirat/on #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 3 of 11 ONEMOletc. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Asphalt Clay and Concrete Tile Metal Slate or Wood (1507.3) Slate -Type Underlayment Shingles Shingles Mechanical Adhesive- Panels Shingles Shingles (iso7.z) Attach Set (2507.4) (1507.5) (15oz7) (1507.8) Shakes (lso7.$) Yes Yes LeakBarrier MS300 Yes No No No No Yes (joint strips, 1507.1.1.3 ljoint strips, 1507.1.1.3 / R905.1.1.3) / R905.1.1.3) TopShield Ice & Water Yes Yes Yes No No No No Yes (joint strips, 1507.1.1.3 Qoint strips, 1507.1.1.3 G300 / R90s.1.1.3) / R905,1.1.3) Yes Yes Yes Yes Yes LeakBarrier P5200HT Yes Yes See 5.6.1 (No copperor (No copper YES (joint strips, 1507.1.1.3 Qoint strips, 1507.1.1.3 zinc) orzinc) / R905.1.1.3) / R905.1.1.3) Yes Yes Yes Yes LeakBarrier P5200mu Yes No No (No (No copper Yes (joint strips, 1507.1.1.3 (joint strips, 1507.1.1.3 copper or zinc) orzinc) / R905.1.1.3) / R905.1.1.3) Yes Yes Yes Yes Yes LeakBarrierNR6000ltra Yes Yes See 5.6.1 (No copperor (No copper Yes (jointstrlpS,1507.1.1.3 (Joint strips,1507.1.1.3 zinc) or zinc) /R905.1.1.3) /R905.1.1.3) Yes Yes LeakBarrier SS400 Yes No No No No Yes (Joint strips, 1507.1.1.3 (joint strips, 1507.1.1.3 / R905.1.1.3) / R905,1.1.3) LeakBarrier EasyLay Yes Yes No No Yes No No See See5. LeakBarrier EasyLay UDL 15 or LeakBarrier EasyLay Yes Yes Yes Yes Yes Yes No No See 5.6.2 See 5.6.2 UDL 30 TopShield EL30 YeS Yes Yes yes Yes Yes No No See 5.6.2 See 5.6.2 Tarco 30 Yes es es5. Yes Yes Yes Yes Yes See 5.Fiberglass See Mineral Yes (Valley No No No No No No No Surfaced Roll Roofing Liner) ASTM Organic Mineral Yes Yes Yes Surface Tile (Valley (Cap Sheet In (Cap Sheet in No No No No No Underlayment Liner) 2-ply system) 2-ply system) ee See 5.6.1 Yes Yes LeakBarrier EasyMop SBS No (Cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) See 5.6.1 NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Cerd icate ojAuthorizatlon #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 4 of 11 ONEMO I etc. 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval LeakBarrier PS200"T Dupont "Tile Bond'" Roof Tile Adhesive" FL22525 LeakBarrier PS200"T, LeakBarrier NR600 Ultra, ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier ICP Adhesives and Sealants "Polyset® AH-160" FL6332 EasyMop SBS LeakBarrier PS200"T ICP Adhesives and Sealants "Polyset® RTA-1" FL6276 5.6.2 Tarco 30, EasyLay, LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 may be used as a mechanically attached anchor sheet followed by an asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS. 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates LeakBarrier MS300 self -adhering (Optional) ASTM D41 plywood; OSB or structural concrete TopShield Ice & Water G300 LeakBarrier PS200"T LeakBarrier PS200"^u LeakBarrier NR600 Ultra LeakBarrier SS400 LeakBarrier MS300 self -adhering none ASTM D226 Type II felt; ASTM D4869 Yp Type III or IV felt; LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 TopShield Ice & Water G300 LeakBarrier PS200"T LeakBarrier PS200Mu LeakBarrier NR600 Ultra LeakBarrier SS400 LeakBarrier M5300 self -adhering ASTM D41 metal (flashing metal, valley metal, etc.) TopShield Ice & Water G300 LeakBarrier PS200"T LeakBarrier PS200Mu LeakBarrier NR600 Ultra LeakBarrier SS400 ASTM Organic Mineral Surface Tile Underlayment hot asphalt ASTM D41 structural concrete LeakBarrier EasyMop SBS ASTM Organic Mineral Surface Tile Underlayment hot asphalt None ASTM D226 Type II felt, ASTM D4601 base sheet LeakBarrier EasyMop SBS 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate of Authorization#32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10450-R14 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 5 of 11 5.8 5.8.1 Attachment Limitations: fONEMOJetc. For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -75.0 usf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier PS200mu, self -adhered. Underlayment: LeakBarrier PS20011T, self -adhered. #2 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional) ASTM D41 Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200mu or LeakBarrier EasyBase, rolled into place to create continuous bond Base Ply: (Optional) LeakBarrier PS200", self -adhered Underlayment: LeakBarrier PS200HT, self -adhered. #3 Maximum Design Pressure = -217.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200HT, self -adhered. #4 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certfflcate oJAuthori:atfon #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913.7750 Revision 14: 03/22/2021 Page 6 of 11 5.8.3.2 Mechanically -Attached Base Sheet: ONEMOletc. The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #5 Maximum Design Pressure = -45 0 psf*, Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200HI, self -adhered. #6 Maximum Design Pressure = -45 0 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows. Primer: ASTM D41 primer at tin -caps. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier NR600 Ultra, self -adhered. #7 Maximum Design Pressure = -60 0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS2001111 self -adhered. #8 Maximum Design Pressure = -60 0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS2001" self -adhered. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Cert/f7cate of Authorhat/on #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913.7750 Revision 14: 03/22/2021 Page 7 of 11 ONEMOletc. #9 Maximum Design Pressure = -60.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30 (48" wide rolls). Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" D.C. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Primer: ASTM D41 primer at tin -caps. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier NR600 Ultra, self -adhered and back nailed using 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps spaced 12" o.c. within the self -adhering side laps. #10 Maximum Design Pressure = -82.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8" D.C. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier P5200mu, self -adhered Underlayment: LeakBarrier PS20011, self -adhered. #11 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 4" o.c. at the 4-inch wide side laps and 4" D.C. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200HT, self -adhered. 5.9 Exposure Limitations: TABLE 3: ExposuRE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) LeakBarrier PS200HT, or ASTM Organic Mineral Surface Tile Underlayment Adhesive -set tile roof system or mechanically attached 180 LeakBarrier NR600 Ultra or LeakBarrier EasyMop SBS Mechanically attached 180 LeakBarrier EasyLay Mechanically attached 180 LeakBarrier EasyLay UDL 30 Mechanically attached 180 LeakBarrier NR600 Ultra or LeakBarrier EasyMop SBS Adhesive -set tile roof system 30 LeakBarrier M5300, P5200Mu, SS400 or TopShield Ice & Water G300 Mechanically attached 30 LeakBarrier EasyLay UDL 15 or TopShield EL30 Mechanically attached 1 30 Tarco 30 Mechanically attached 1 1 NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certlffcate of Authori:at/on #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913.7750 Revision 14: 03/22/2021 Page 8 of 11 ONEMOJetc. 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment* Tile Profile Staging Method Maximum Slope LeakBarrier PS200HT Flat 10-tile stack** or 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 6:12 LeakBarrier NR600 Ultra Flat or Lugged 6-tile stack (4 over 2) 6:12 ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS Flat 6-tile stack (4 over 2) 5:12 lugged 6-tile stack (4 over 2) 6:12 Notes: *Tarco Roofing specifies a minimum 48 cure -time after the installation of self -adhering membranes and before loading of roofing tiles. **If tiles are to be left in a staged condition for more than 30 days, Tarco Roofing requires tiles be staged two tiles perpendicular to slope, four tiles on top, parallel to slope, regardless of the allowances noted above 6. INSTALLATION: 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tarco 30: 6.3.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.3.2 Tile Applications: Tarco 30 is limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS applied in hot asphalt, or other FBC Approved hot -asphalt applied cap sheet. Refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 for attachment requirements. 6.4 LeakBarrier EasyLay: 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate ofAuthari:ation #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 9 of 11 ONEMOjetc. 6.4.2 Tile Applications: LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition • When LeakBarrier EasyLay is followed by ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS applied in hot asphalt, or other FBC Approved hot -asphalt applied cap sheet, refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 for attachment requirements. • When LeakBarrier EasyLay is followed by LeakBarrier PS200"T, refer to Section 5.8.3.2 herein for attachment requirements. 6.5 LeakBarrier EasyLay UDL 15, TopShield EL30 or LeakBarrier EasyLay UDL 30: —� 6.5.1 Non -Tile Applications: Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.2 Tile Applications: LeakBarrier EasyLay UDL 15, TopShield EL30 and LeakBarrier EasyLay UDL 30 are limited to use as a mechanically attached base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by LeakBarrier PS20011TI self -adhered. Refer to Section 5.8.3.2 herein for attachment requirements. 6.6 LeakBarrier® MS300, LeakBarrier® PS200mu, LeakBarrier® SS400 Ice and Water Armor or TopShield Ice & Water G300: 6.6.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (HSI IV] ulyiu) In FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869, Type III or IV felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.6.2 Multi -Ply Underlayment Systems: LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. 6.7 LeakBarrier® PS200"T or LeakBarrier® NR600 Ultra: 6.7.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt or ASTM D4869, Type III or IV felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.7.2 Tile Applications: Shall be installed in compliance with requirements for a Self -Adhered Membrane in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.2 for attachment limitations. Refer to Table 4 for tile staging limitations. NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate ofAuthorfratfon #32455 7T" EDITION (2020) FBC NON-HVH2 EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913.7750 Revision 14: 03/22/2021 Page 10 of 11 ONEMOjetc. 6.8 ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier m EasyMop SBS: 6.8.1 Tile Applications: ASTM Organic Mineral Surface Tile Underlayment and LeakBarrierTm EasyMop SBS are limited to use as the Hot Asphalt applied "Cap Sheet" in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. Refer to Section 5.8.2 for attachment limitations. Refer to Table 4 for tile staging limitations. 6.9 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral Surface Tile Underlayment: 6.9.1 Fiberglass Mineral Surface Roll Roofing and ASTM Organic Mineral Surface Tile Underlayment are limited to use as a valley liner in accordance with FBC 1507.2.9.2 or FBC Residential R905.2.8.2. Installation shall be in accordance with the manufacturer's instructions before applying shingles. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 611320-3 CIA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC — QUA9625; (414) 248-6409; Karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 10880.07.08-1114 Certificate of Authori:ation#32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION F1.10450-1114 Tarco Roof Underlayments; (254) 913-7750 Revision 14: 03/22/2021 Page 11 of 11