Loading...
HomeMy WebLinkAboutBuilding permit appAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 2 Permit Number:_ S P-ermit-Application__—�------__.. Planning and Development Services X Building and Code Regulation Division Commercial Residential 2300 Virginia Avenue, Fart Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1.578 PE RMITAPPLICATION FOR: PRPQRIMP'ROWE�IEfU1OCA2_C01�1 Address: 121 queen ann ct — Property Tax ID ft: 1414-701-0203-000-9 Lot No. Site Plan Name: Block No. Project Name: barbara (anger LIKE FOR LIKE L4CC1C aN�Gc�6.ci New Electrical Meter Second Electrical Meter _ ------------- Additional work to be performed under this permit— check all that apply: Mechanical _Gas Tank _Gas Piping _Shutters _Windows/Doors _Pond _Electric _Plumbing _Sprinklers ^Generator _Roof _Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 7484,00 Utilities: _Sewer _ Septic Building Height: O�NR/LESSEE, _4.F CONZaw,�t� Name barbara longer Name: Christopher Langel Address: 121 queen ann ct company: Sea Coast A/C and Sheet Metal Inc. city: fort pierce State: fL- Address: 3108 Industrial 31 st Street Zip Code: 34949 _ Fax: city: Ft Pierce _State: FL Phone No. 777-595-3645 _ Zip Code: 34946 Fax: 772-448-4416 E-Mall: Phone No 772-466-2400 Pill in fee simple Title Holder on next page ( if different E-Mail info�GParnactair rnm from the owner listed above) State or County License CMC035421 If value of construction is 2500 or more, a RECORDED Notice of commencement Is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. Address: City: FEESIMPLETITLEHOLOER: ^NotApplicabie Name: — City: Zip:_ one: MORTGAGE COMPANY: Address: City:,_ BONGING COMPANY: Address: City: Phone: _ Not Applicable Nol Applicable OWNER/ CONTRACTOR AFFIDVIT: Application Is hereby made to obtain a pet'mit to do the work and installation as indicated. certify that no work or installation has commenced prior to the Issuance of a permit. St. Lucie Coun makes norepresentationthat is granting a 1permit will authorize the permit holder to build the subject structure structure, Please consult wlthpyour Home Owners Assoclia lion and review your deed for any restrits ctions whichtmeay aprohibit such In -consideration of the granting of this requested.penmit, Ldo hereby agree that will, In all. respects,,perform_the work in accordance with the approved plans, the Hof lea Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property: A Notice of Commencement most be recorded in the public records suott Lucie County and posted on the fobsite before the first Inspection. If you intend to obtain financing, with lender or an attorney before commencin work or record�inE our No ice of Commencement. l R I al of Owner/ Lessee/Contractor as Agent STATE OF FLO,QIpA ' S orn to (or affirmed) and subscribed before me of Physical Presence or_Online Notarization this�_dayof november 2021 by 0 r I '� i7�t P Ii y r ti q P, Name of person making statement. Personally Known X. OR Produced Identification Type of Identification Commission Signature STATE OF F COUNTY OF r I��a � _ S *If to (or affirmed) and subscribed before me ofnl physical Presence or Online Notarization thdayof noyeeer ,2021 by Name of person makbggstatement. Personally Known X OR Produced Identification Type of Identification of Notary Public- Stateiof Plorida Project SJob: 121 Queen Ann Court, Fort., ecSummary - Wrightsoft0 ry Daea: Nov09,2021 Entire House By: SeacoastAir CondMoning Sea Coast Air Conditioning 3109Ird,stdal Died, Fat Piece, R34946Rh 7724E62400 Emdl:dspatd) spa Cara •Information For: Barbara Langer 121 Queen Ann Court, Fort Pierce, FL 34949 Phone: 772 595-3645 Notes: 121 QueenAnn Court, Fort Pierce, FL, 34949 Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 42 OF Outsidedb 90 OF Insidedb 70 OF Insidedb 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/b Heating Summary Sensible Cooling Equipment Load Sizing Structure 21421 Btuh Structure 17430 Btuh Ducts 6655 Btuh Ducts 9570 Btuh Central vent (144 cfin) 4446 Btuh Central vent (144 drn) 2382 Btuh Outside air Outside air Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipmentload 32522 Btuh Use manufacture's data n Rate/swing multiplier 0,95 Infiltration Equipment sensible load 29533 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4423 Btuh Ducts 2629 Btuh Central vent (144 cm) 6036 Btuh Heating Cooling Outside air Area (ft2) 1816 1816 Equipment latent load 13088 Btuh Volume (ft) 14528 14528 Air chapges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 42621 Btuh Equiv AVF (cfm) 92 48 Req, total capacity at 0,70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade Lennox Model Cond ML14XC1-47-230A AHRI ref Coil CBA25UHV-048-230 AHRI ref 202540560 Efficiency 80AFUE Efficiency 13.0 EER, 16 SEER Heating input 0 Btuh Sensible Cooling 32550 Btuh Heating output0 Btuh Latent cooling 13950 Btuh Temperature rise 0 OF Totalcooling 46500 Btuh Actual air flow 1655 cfin Actual air flow 1655 cfm Air flow factor 0.059 cfm/Btuh Air flow factor 0.061 cfm/Btuh Static pressure 0.60 in H2O Static pressure 0.60 in H2O Space thermostat Load sensible heat ratio 0.70 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Tr wri9hts oft" 2021Na�iparja1 .,... Ri<jd9il�Urivesa1271919.n.13RSU�14 Pei ACC\ C:1Uses\mesatDe ktTTaWDwt De igi.np CaIc=MJ8 FmWwrfx : E Static Pressure and Friction Rate Job: Queen Ann Court Fort.. No -- wrightsoft° Date: Nov09,2021 Entire House By: Seacoast Air Conditioning Sea Coast Air Conditioning 310B frdztdal Shed, Fat Piece, FL34946Pfm 7724662400 Emdl:alsrld)@sea00%iara Project• • For: Barbara Langer 121 Queen Ann Court, Fort Pierce, FL 34949 Phone: 772 595-3645 Heating Cooling (in H2O) (in H2O) External static pressure 0.60 0.60 Pressure losses Coil 0.10 0.10 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0,03 0.03 Filter 0.08 0.08 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0,36 0,36 e Supply Return (ft) (ft) Measured length of run -out 15 3 Measured length of trunk 25 0 Equivalent length of fittings 130 60 Total length 170 63 Total effective length 233 Friction Supply Duds Return Ducts Heating Cooling Fitting EquivalenYLength (Details Supply 4AD=60, 11A=20511G=51 11G=51 11G=51 1A=35: TotalEL=130 Return 5D=40, 6M=20: TotalEL=60 d'zozl�lo,mlt:3zo� t �`l� WryghtsoR" Ri¢AStite®UrJvesal2)7919.0.13RSU96A4 Pagel ACCt1 C:\Usas�a+asa�Deek(op�1 JaDW Deslgi.n{o Cdc=MJe FrtrtDarfxa: E Duct System Summary Job: 121 Queen AnnCour,Fort.. wrightsoft' y ry Date: rtovo9,2021 Entire House By: seacoast Air Conditioning Sea Coast Air Conditioning 310BIndsMal SVeet,Fcd Pie ,,FL34946Pftc0 772495,2400 EMOiI:dSP6td)@SeaWRAd1= For: Barbara Langer 121 QueenAnn Court, Fort Pierce, FL 34949 Phone: 772 595-3645 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.60 in H2O 0.24 in H2O 0,36 in H2O 0.263 / 0.097 in H2O 0.155 in/100ft 1655 cffn 233 ft Cooling 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.263 / 0.097 in H2O 0.155 in/100ft 1655 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfrn) Clg (crm) Design FR Diam (in) H x W (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bah h 919 54 27 0,190 4.0 Ox0 VIFx 18.2 120.0 st2 Bel= h 3790 223 138 0,163 8.0 Ox0 MFx 36.2 125.0 st2 DINNRo c 2246 104 138 0.203 6.0 Ox0 VIFx 29.4 100.0 Dirirg RO nA c 2246 104 138 0.213 6.0 Ox0 VIFx 23.0 100.0 NtcrwAEh4876 125 217 0.240 8.0 Ox0 VIFx 14.3 95.0 nvirg Rm 142 167 0.227 7.0 Ox0 VIFx 10.8 105.0 Living RMA 142 167 0.158 7.0 Ox0 VIFx 35.7 130.0 stl Uvtrg RmB 142 167 0.174 7.0 OxO VIFx 31.1 120.0 stl Masta-Bdmn 287 250 0.155 9.0 Ox0 MFx 39.8 130.0 stl MsireE#h 117 49 0.164 5.0 OxO VFx 40.2 120.0 stl MstrCi-A 33 31 0.168 4.0 OxO VIFx 36.3 120.0 st1orc�a 182 167 0.176 7.0 OxO MFx 1 29.3 1 120.0 1 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (clin) (cfm) FIR ) (in) Material Trunk st1 PeakAVF 721 664 0.15574 f585 14.0 0 x 0 VInlFbc st2 PeakAVF 460 332 0.163 12,0 0 x 0 VinlFbc Bold�A�llc t2lues hava bey rrenually ovariddm _ � wrightsoft` 2o214dam 1t:3zW RlgiStite'DUrivesal 201919.0.13RSU22S44 f age 1 C:\Usas�asa�Desktop\t JaDud Desigi.np CaIc=MJe Fmifba'faz>: E Return Branch Detail Table Name Grille Sze (in) Htg (cfm) Clg (cfm) TEL M Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox0 1655 1655 63.0 0.155 759 20.0 Ox 0 VIFx Bcldrrtalic ralua ham ban rten ually oeariddm 2021�Jw/611:3Z07 �_— -PFI- wrightsoft" RlydSitWUnvasd Z01919.0.13 RSU28W Fdg32 /h+CP. C:\UseslavesdDaMopU.axJaDucl DPsigi.nn C�c=MJB Fmd0arfaces: E Manual S Compliance Report Job: 121 Queen Ann Cou t Fort.. omp -�d- wrightsoft® Date: Nov09,2021 Entire House By: SeacoastAir Conditioning Sea Coast Air Conditioning Project Information For; Barbara Langer 121 Queen Ann Court, Fort Pierce, FL 34949 Phone: 772 595-3645 Design Conditions Outdoor design DB: 90.0°F Sensible gain; 31088 Btuh Outdoor designWB: 78.0°F Latent gain: 13088 Btuh Indoordesign DB: 75.0°F Totalgain: 44176 Btuh Indoor RH: 50% Estimated airflow: 1655 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmentiype: SpIdAC Manufacturer: Lennox Model: ML14XC147-230A+CBA25UHV-048-230 Actual airflow: 1655 cfm Sensible capacity: 32550 Btuh 105%of load Latent capacity: 13950 Btuh 107%of load Total capacity: 46500 Btuh 105%ofload SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 42.0°F Heat loss: 32522 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Gas furnace Manufacturer: Model: Actual airflow: 1655 cfm Outputcapacity: 0 Btuh 0%of bad Meets all requirements ofACCA Manual S. Entering coil DB: 79.0°F Entering coil WB: 65.3°F Entering coil DB: 67.0°F Temp. rise: 0 °F _ -t�l- wrightsoft° zon�wwn:azm m°,� Ri�19it�UrlVasa12J1919.e.13 RSU2ffi94 p�yf /�+C.A C:1Uses�asa�DesklcpllayaDW DesigtNp CAc=MJ9 FmiDaffaes: E #: 121 Queen Ann Court, Fort Pierce, ... armed by SeacoastAir Co nd'ttioning f... Barbara Langer 121 Queen Ann Court Fort Pierce, FL 34949 Phone: 772 595-3645 Level2 Sea Coast Air Conditioning 31081ndustrial Street Fort Pierce, FL 34946 Phone: 772466-2400 dispatch@seacoastaircom Scale:1 :107 Page 1 RightSuite®Universa12019 19.0.13 RSU28644 2021-Nov-09 11:33:03 ...a\Desktop\Langer Duct Design.rup