In-Place Density Test Report
Client:JMC CONTRACTING, INC.UES Technician:Amber Evans
601 SE Central Parkway
Stuart, FL 34994
Date Tested:11/08/2021
Project:JMC CONTRACTING, INC.
Various Locations, TBD County, FL
Type of Test:
Area Tested:12769 NW Mariner Court, Palm City -
Addeo Res. - Permit #21070040
Field:ASTM D-6938 Nuclear Gauge Method
Material:Native Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 NW side of pad.0-1 ft 112.8 10.8 108.7 11.0 96 Pass
2 SE side of pad.0-1 ft 112.8 10.8 108.2 11.1 96 Pass
3 Center of pad.0-1 ft 112.8 10.8 107.3 10.9 95 Pass
Remarks:No forms or plumbing present.
1-2' NW side HCP=60+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the
soil.
1-2' SE side HCP=50+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil.
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G. Abubakar,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1