Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NEW Prop Manual J Updated
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 1 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Load Short Form Jul 15, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Thomas Residence, Air Conditioning Unlimited, LLCFor: 5313 S 25th St, Fort Pierce, FL 34981 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S042-230A** AHRI ref Coil CBA27UHE-042-230*++TDR AHRI ref 10259441 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW8.1 Sensible cooling Btuh29400 Heating output Btuh27587 Latent cooling Btuh12600 Temperature rise °F18 Total cooling Btuh42000 Actual air flow cfm1400 Actual air flow cfm1400 Air flow factor cfm/Btuh0.049 Air flow factor cfm/Btuh0.049 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Bed 2 161 2830 1781 140 88 Bath 2 54 726 386 36 19 Lin 6 0 0 0 0 Hall 30 0 0 0 0 Bed 3 173 3070 2151 151 106 Family Room 185 4286 5645 211 278 Kitchen/Nook 215 1963 5095 97 251 Living Room 266 1950 4106 96 202 Laundry 77 1064 889 52 44 Dining Room 108 2190 1885 108 93 Foyer 72 1146 607 57 30 Wtr Clst 28 1275 604 63 30 Linen 5 0 0 0 0 WIC 42 764 251 38 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 2 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N Master Bath 129 1652 828 82 41 Master Bedroom 217 5459 4225 269 208 House d 1766 28375 28454 1400 1400 Other equip loads 1519 807 Equip. @ 0.95 RSM 27914 Latent cooling 7063 TOTALS 1766 29894 34977 1400 1400 2021-Nov-11 13:33:35 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 1 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Building Analysis Jul 15, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Thomas Residence, Air Conditioning Unlimited, LLCFor: 5313 S 25th St, Fort Pierce, FL 34981 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 15.445973.1Walls 19.7588717.5Glazing 0.51483.7Doors 5.516540.9Ceilings 19.959493.43.4Floors 11.032852.0Infiltration 22.96856Ducts 00Piping 00Humidification 5.11519Ventilation0Adjustments 100.029894Total Cooling Walls Glazing OtherCeilingsInfiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 9.427521.9Walls 26.1764122.8Glazing 0.51503.7Doors 4.613480.8Ceilings 000Floors 3.19180.6Infiltration 26.17624Ducts 2.8807Ventilation 27.48020Internal gains 00Blower 0Adjustments 100.029260Total Latent Cooling Load = 7063 Btuh Overall U-value = 0.117 Btuh/ft²-°F Data entries checked. 2021-Nov-11 13:33:35 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 1 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Component Constructions Jul 15, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Thomas Residence, Air Conditioning Unlimited, LLCFor: 5313 S 25th St, Fort Pierce, FL 34981 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd Ins, 8" Thk, 1/2" Gyp Bd Int Fnsh 1303.155.10.10941n 832.02 6042.029443.155.10.109300ne 4192.026543.155.10.109208se 7502.0211723.155.10.109372sw 6342.029923.155.10.109315nw 24902.0238923.155.10.1091235all Partitions Frm Wall, 1/2" Gyp.Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 2621.097052.9411.00.101240 Windows Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 14 ft overhang (6.7 ft window ht, 3 ft sep.); 6.8 ft head ht 45911.972618.800.65039n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); foreground = green grass (0.23); 1 ft overhang (1.2 ft window ht, 1 ft sep.); 6.8 ft head ht 13127.48116.800.5805ne Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 34722.326216.800.58016ne 66921.552516.800.58031sw 101721.778716.800.58047all Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); foreground = green grass (0.23); 6.6 ft overhang (1.6 ft window ht, 1 ft sep.); 6.8 ft head ht 15316.016116.800.58010se Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (6.8 ft window ht, 1 ft sep.); 9 ft head ht 88621.768616.800.58041se Impact, Clear Low-e, TEMP: Impact, Clear Low-e, TEMP; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (3 ft window ht, 1 ft sep.); 6.8 ft head ht 18620.615116.800.5809se 2021-Nov-11 13:33:35 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 2 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 20 ft overhang (5.2 ft window ht, 3 ft sep.); 6.8 ft head ht 20913.426216.800.58016sw Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (6.7 ft window ht, 3 ft sep.); 6.8 ft head ht 87122.074718.800.65040sw Impact, TEMP, OBSC: Impact, TEMP, OBSC; NFRC rated (SHGC=0.24); foreground = green grass (0.23); 1 ft overhang (3 ft window ht, 1 ft sep.); 6.8 ft head ht 15125.110116.800.5806sw Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 3 ft sep.); 6.8 ft head ht 104122.378716.800.58047nw Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 10 ft overhang (5.2 ft window ht, 3 ft sep.); 6.8 ft head ht 34722.326216.800.58016nw 51122.338616.800.58023nw 85822.364916.800.58039all Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 16 ft overhang (6.7 ft window ht, 3 ft sep.); 6.8 ft head ht 86021.774718.800.65040nw Doors Door, wd sc type: Fbrgls Door 1503.731483.697.00.12740se Ceilings Attic, Shngl Roof, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh 0.0341766 13480.7616540.9430.0 Floors On Grade Depth, Tile Flr Fnsh 00594928.700.989207 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 1 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Project Summary Jul 15, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Thomas Residence, Air Conditioning Unlimited, LLCFor:5313 S 25th St, Fort Pierce, FL 34981 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh21520 Structure Btuh20829 Ducts Btuh6856 Ducts Btuh7624Central vent (48 cfm) 1519 Btuh Central vent (48 cfm) Btuh807 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh29894 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh27914 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2896 Ducts Btuh2325Central vent (48 cfm) Btuh1842 CoolingHeating Outside air17661766Area (ft²) Equipment latent load Btuh7063 1627416274Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh34977 Equiv. AVF (cfm) 54103 Req. total capacity at 0.70 SHR ton3.3 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond ML14XC1S042-230A**AHRI ref Coil CBA27UHE-042-230*++TDR AHRI ref 10259441Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW8.1 Sensible cooling Btuh29400Heating output Btuh27587 Latent cooling Btuh12600 Temperature rise °F18 Total cooling Btuh42000Actual air flow cfm1400 Actual air flow cfm1400 Air flow factor cfm/Btuh0.049 Air flow factor cfm/Btuh0.049Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 1...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Bed 2 2 Exposed wall 207.4 ft 29.0 ft 3 Room height 9.2 dft 8.1 heat/coolft 4 Room dimensions ft161.3x1.0 5 Room area 1765.8 ft²161.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 80 41 130 83 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 39 0 726 459 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 320 300 944 604 113 98 308 197 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 5 0 81 131 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 16 0 262 347 16 0 262 347 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 307 208 654 419 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 10 10 161 153 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 41 4 686 886 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 9 2 151 186 0 0 0 0 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 40 40 148 150 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 464 372 1172 750 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 31 4 525 669 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 16 16 262 209 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 40 0 747 871 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 6 1 101 151 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 440 315 992 634 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 47 0 787 1041 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 16 0 262 347 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 23 0 386 511 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 40 0 747 860 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 240 240 705 262 122 122 357 133 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 1766 1766 1654 1348 161 161 151 123 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 1766 207 5949 0 161 29 832 0 6 c) AED excursion 819 -65 Envelope loss/gain 18235 11891 1910 736 12 a) Infiltration 3285 918 231 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 7100 500 Subtotal (lines 6 to 13)21520 20829 2141 1300 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 5 4 14 Subtotal 21520 20829 2146 1304 15 Duct loads 32%37%6856 7624 32%37%684 477 Total room load 28375 28454 2830 1781 Air required (cfm)Air required (cfm)1400 1400 140 88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 2...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath 2 Lin 2 Exposed wall 6.0 ft 0 ft 3 Room height 8.1 heat/coolft 8.1 heat/coolft 4 Room dimensions ft6.0x9.0 ft2.5x2.5 5 Room area 54.0 ft²6.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 49 44 138 88 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 5 0 81 131 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 0 0 0 0 0 0 0 0 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 0 0 0 0 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 54 54 51 41 6 6 6 5 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 54 6 172 0 6 0 0 0 6 c) AED excursion -14 0 Envelope loss/gain 441 247 6 5 12 a) Infiltration 99 28 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)540 275 6 5 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 10 8 -6 -5 14 Subtotal 550 282 0 0 15 Duct loads 32%37%175 103 32%37%0 0 Total room load 726 386 0 0 Air required (cfm)Air required (cfm)36 19 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 3...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Hall Bed 3 2 Exposed wall 0 ft 27.5 ft 3 Room height 8.1 heat/coolft 8.1 heat/coolft 4 Room dimensions ft8.5x3.5 ft172.5x1.0 5 Room area 29.8 ft²172.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 122 122 383 245 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 0 0 0 0 0 0 0 0 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 0 0 0 0 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 101 86 270 173 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 16 0 262 347 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 30 30 28 23 173 173 162 132 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 30 0 0 0 173 28 789 0 6 c) AED excursion -1 45 Envelope loss/gain 28 22 1865 941 12 a) Infiltration 0 0 454 127 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)28 22 2320 1568 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -28 -22 8 7 14 Subtotal 0 0 2328 1575 15 Duct loads 32%37%0 0 32%37%742 576 Total room load 0 0 3070 2151 Air required (cfm)Air required (cfm)0 0 151 106 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 4...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Family Room Kitchen/Nook 2 Exposed wall 25.0 ft 10.5 ft 3 Room height 10.1 heat/coolft 10.1 heat/coolft 4 Room dimensions ft185.0x1.0 ft214.5x1.0 5 Room area 185.0 ft²214.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 0 0 0 0 0 0 0 0 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 101 61 193 124 61 45 142 91 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 0 0 0 0 16 16 262 209 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 40 0 747 871 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 152 120 379 242 45 30 94 60 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 31 0 525 694 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 16 0 262 347 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 185 185 173 141 215 215 201 164 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 185 25 717 0 215 11 301 0 6 c) AED excursion 185 132 Envelope loss/gain 2735 2258 1263 1002 12 a) Infiltration 515 144 216 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 2 460 Appliances/other 1500 2200 Subtotal (lines 6 to 13)3249 4132 1479 3723 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 1 1 10 8 14 Subtotal 3251 4133 1489 3730 15 Duct loads 32%37%1036 1513 32%37%474 1365 Total room load 4286 5645 1963 5095 Air required (cfm)Air required (cfm)211 278 97 251 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 5...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Living Room Laundry 2 Exposed wall 7.5 ft 14.0 ft 3 Room height 10.1 heat/coolft 8.1 heat/coolft 4 Room dimensions ft265.5x1.0 ft11.0x7.0 5 Room area 265.5 ft²77.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 0 0 0 0 0 0 0 0 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 0 0 0 0 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 76 36 114 73 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 40 0 747 860 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 0 0 0 0 113 113 333 124 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 266 266 249 203 77 77 72 59 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 266 8 215 0 77 14 402 0 6 c) AED excursion 197 -32 Envelope loss/gain 1325 1333 807 150 12 a) Infiltration 154 43 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 0 0 Appliances/other 1400 500 Subtotal (lines 6 to 13)1479 3006 807 650 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1479 3006 807 650 15 Duct loads 32%37%471 1100 32%37%257 238 Total room load 1950 4106 1064 889 Air required (cfm)Air required (cfm)96 202 52 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 6...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Dining Room Foyer 2 Exposed wall 12.5 ft 8.0 ft 3 Room height 10.1 heat/coolft 10.1 heat/coolft 4 Room dimensions ft9.0x12.0 ft9.0x8.0 5 Room area 108.0 ft²72.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 121 80 253 162 81 31 98 62 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 0 0 0 0 10 10 161 153 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 41 4 686 886 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 0 0 0 0 0 0 0 0 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 40 40 148 150 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 0 0 0 0 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 5 5 15 6 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 108 108 101 82 72 72 67 55 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 108 13 359 0 72 8 229 0 6 c) AED excursion 175 -22 Envelope loss/gain 1414 1311 704 398 12 a) Infiltration 247 69 165 46 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1661 1380 869 444 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1661 1380 869 444 15 Duct loads 32%37%529 505 32%37%277 163 Total room load 2190 1885 1146 607 Air required (cfm)Air required (cfm)108 93 57 30 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 7...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Wtr Clst Linen 2 Exposed wall 11.5 ft 1.5 ft 3 Room height 8.1 heat/coolft 8.1 heat/coolft 4 Room dimensions ft8.0x3.5 ft1.5x3.5 5 Room area 28.0 ft²5.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 28 28 89 57 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 0 0 0 0 0 0 0 0 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 65 59 185 119 12 12 38 24 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 0 0 0 0 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 6 1 101 151 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 28 28 26 21 5 5 5 4 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 28 12 330 0 5 2 43 0 6 c) AED excursion 27 -2 Envelope loss/gain 732 375 86 27 12 a) Infiltration 190 53 25 7 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)921 428 111 34 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 46 14 -111 -34 14 Subtotal 967 442 0 0 15 Duct loads 32%37%308 162 32%37%0 0 Total room load 1275 604 0 0 Air required (cfm)Air required (cfm)63 30 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 8...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name WIC Master Bath 2 Exposed wall 7.0 ft 14.0 ft 3 Room height 8.1 heat/coolft 8.1 heat/coolft 4 Room dimensions ft41.5x1.0 ft128.8x1.0 5 Room area 41.5 ft²128.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 11.9211.92 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nene 3.153.15 2.022.02 0 0 0 0 36 36 115 73 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 27.3727.37 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nene 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 sese 3.153.15 2.022.02 0 0 0 0 77 68 214 137 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 15.9615.96 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 sese 16.8216.82 21.7221.72 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e, 0.580Impact, Clear Low-e, 0.580 sese 16.8216.82 20.6420.64 0 0 0 0 9 2 151 186 DD Door, wd sc typeDoor, wd sc type 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 swsw 3.153.15 2.022.02 57 57 179 114 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 21.4621.46 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 swsw 16.8216.82 13.3713.37 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 swsw 18.8518.85 21.9821.98 0 0 0 0 0 0 0 0 GG Impact, TEMP, OBSC 0.580Impact, TEMP, OBSC 0.580 swsw 16.8216.82 25.1125.11 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nwnw 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nwnw 16.8216.82 22.2522.25 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nwnw 18.8518.85 21.7021.70 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp.B 0.101Frm Wall, 1/2" Gyp.B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.940.94 0.760.76 42 42 39 32 129 129 121 98 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 42 7 201 0 129 14 402 0 6 c) AED excursion -8 41 Envelope loss/gain 418 138 1002 536 12 a) Infiltration 116 32 231 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)534 170 1234 600 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 46 14 20 6 14 Subtotal 580 184 1253 606 15 Duct loads 32%37%185 67 32%37%399 222 Total room load 764 251 1652 828 Air required (cfm)Air required (cfm)38 12 82 41 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:33:35Right-Suite® Universal 2021 21.0.08 RSU27054 Page 9...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Right-J® Worksheet Jul 15, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bedroom 2 Exposed wall 33.4 ft 3 Room height 9.4 heat/coolft 4 Room dimensions ft216.5x1.0 5 Room area 216.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Blk Wall, Stucco Ext 0.109 n 3.15 2.02 80 41 130 83 .G Impact, Clear Low-e 0.650 n 18.85 11.92 39 0 726 459 .W Blk Wall, Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 .G Impact, Clear Low-e 0.580 ne 16.82 27.37 0 0 0 0 11 G Impact, Clear Low-e 0.580 ne 16.82 22.25 0 0 0 0 W Blk Wall, Stucco Ext 0.109 se 3.15 2.02 0 0 0 0 G Impact, Clear Low-e 0.580 se 16.82 15.96 0 0 0 0 G Impact, Clear Low-e 0.580 se 16.82 21.72 0 0 0 0 G Impact, Clear Low-e, 0.580 se 16.82 20.64 0 0 0 0 D Door, wd sc type 0.127 se 3.69 3.73 0 0 0 0 W Blk Wall, Stucco Ext 0.109 sw 3.15 2.02 169 138 435 278 G Impact, Clear Low-e 0.580 sw 16.82 21.46 31 4 525 669 G Impact, Clear Low-e 0.580 sw 16.82 13.37 0 0 0 0 G Impact, Clear Low-e 0.650 sw 18.85 21.98 0 0 0 0 G Impact, TEMP, OBSC 0.580 sw 16.82 25.11 0 0 0 0 W Blk Wall, Stucco Ext 0.109 nw 3.15 2.02 66 43 135 86 G Impact, Clear Low-e 0.580 nw 16.82 22.25 0 0 0 0 G Impact, Clear Low-e 0.580 nw 16.82 22.25 0 0 0 0 G Impact, Clear Low-e 0.580 nw 16.82 22.25 23 0 386 511 G Impact, Clear Low-e 0.650 nw 18.85 21.70 0 0 0 0 P Frm Wall, 1/2" Gyp.B 0.101 -2.94 1.09 0 0 0 0 C Attic, Shngl Roof, R 0.034 -0.94 0.76 217 217 203 165 F On Grade Depth, Tile 0.989 -28.68 0.00 217 33 958 0 6 c) AED excursion 161 Envelope loss/gain 3498 2413 12 a) Infiltration 642 179 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 500 Subtotal (lines 6 to 13)4140 3093 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4140 3093 15 Duct loads 32%37%1319 1132 Total room load 5459 4225 Air required (cfm)269 208 2021-Nov-11 13:33:36 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 1 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Duct System Summary Jul 15, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Thomas Residence, Air Conditioning Unlimited, LLCFor: 5313 S 25th St, Fort Pierce, FL 34981 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.509 / 0.191 in H2O in H2O0.509 / 0.191 Lowest friction rate in/100ft0.149in/100ft0.149 Actual air flow cfm1400cfm1400 Total effective length (TEL) ft469 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st1200.019.3VlFx0x04.00.2322343726hBath 2 st1200.024.3VlFx0x07.00.2271051682830hBed 2 st4300.041.2VlFx0x08.00.1491271823070hBed 3 st3200.09.4VlFx0x07.00.2431111302190hDining Room st4300.029.4VlFx0x08.00.1551671272823cFamily Room st4300.033.8VlFx0x08.00.1531671272823cFamily Room-A st2200.038.9VlFx0x05.00.21336681146hFoyer st1200.014.4VlFx0x06.00.237100391698cKitchen/Nook st4300.032.3VlFx0x06.00.153100391698cKitchen/Nook-A st4300.040.1VlFx0x06.00.150100391698cKitchen/Nook-B st3200.08.9VlFx0x05.00.24452631064hLaundry st2200.039.6VlFx0x07.00.212121582053cLiving Room 00VlFx0x000121582053cLiving Room-A st2200.039.8VlFx0x06.00.21249981652hMaster Bath st2200.048.6VlFx0x07.00.2051251622729hMaster Bedroom st2200.039.0VlFx0x07.00.2131251622729hMaster Bedroom-A st2200.036.8VlFx0x04.00.2151545764hWIC st2200.042.5VlFx0x05.00.21036761275hWtr Clst Bold/italic values have been manually overridden 2021-Nov-11 13:33:36 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 2 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 513 661 0.149 618 14.0 0x0 VinlFlx st1 st1 Peak AVF 762 889 0.149 832 14.0 0x0 VinlFlx st2 Peak AVF 667 506 0.205 850 12.0 0x0 VinlFlx st3 Peak AVF 193 164 0.243 552 8.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb4 0x 3680 264 127.9 0.149 469 12.0 x0 0 VlFx rt1 rb3 0x 1820 127 85.4 0.224 521 8.0 x0 0 VlFx rt1 rb2 0x 1680 105 76.9 0.248 480 8.0 x0 0 VlFx rt1 rb1 0x 9050 1062 83.2 0.229 601 18.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1622 1559 0.149 744 20.0 0x0 VinlFlx 2021-Nov-11 13:33:36 Right-Suite® Universal 2021 21.0.08 RSU27054 Page 1 ...oft HVAC\5313 S 25th St Thomas Res PSL Prop.rup Calc = MJ8 Front Door faces: N 1282Job:Manual S Compliance Report Jul 15, 2020Date:House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Thomas Residence, Air Conditioning Unlimited, LLCFor: 5313 S 25th St, Fort Pierce, FL 34981 Cooling Equipment Design Conditions °F76.5Entering coil DB:Btuh29260Sensible gain:°F90.4Outdoor design DB: °F63.7Entering coil WB:Btuh7063Latent gain:°F77.4Outdoor design WB: Btuh36323Total gain:°F75.0Indoor design DB: cfm1400Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: ML14XC1S042-230A**+CBA27UHE-042-230*++TDRModel:LennoxManufacturer: cfm1400Actual airflow: % of load100Btuh29400Sensible capacity: % of load178Btuh12600Latent capacity: %70SHR:% of load116Btuh42000Total capacity: Heating Equipment Design Conditions °F68.6Entering coil DB:Btuh29894Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1400Actual airflow: °F50Temp. rise:% of load92kW8.1Output capacity: Meets all requirements of ACCA Manual S. Job #: 1282 Performed by Vicki Lynne Nisa for: Thomas Residence 5313 S 25th St Fort Pierce, FL 34981 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 243 Page 1 Right-Suite® Universal 2021 21.0.08 RSU27054 2021-Nov-11 13:33:52 ... 25th St Thomas Res PSL Prop.rup N Level 1 Garage Bed 2 Bath 2 LinHall Bed 3 Family Room Kitchen/Nook Living Room Laundry Dining RoomFoyer Wtr Clst Linen WIC Master Bath Master Bedroom 10 x 10 167 cfm 10 x 10 167 cfm 8 x 8 100 cfm 8 x 8 100 cfm 10 x 10 162 cfm 10 x 10 162 cfm 12 x 8 182 cfm 12 x 8 168 cfm 10 x 6 100 cfm 8 x 4 45 cfm 10 x 6 76 cfm 8 x 8 98 cfm 12 x 8 130 cfm 10 x 6 68 cfm 10 x 6 63 cfm 12 x 8 121 cfm 36 x 18 1062 cfm 12 x 12 168 cfm 12 x 12 182 cfm 16 x 16 368 cfm 8 x 4 43 cfm 20 " 8 " 8 " 12 " 5 " 7 " 5 " 7 " 7 " 7 " 4 " 5 " 6 " 12 " 8 " 6 " 14 " 7 " 4 " 14 " 6 " 6 "8 " 8 "8 "