HomeMy WebLinkAboutProject Information 11-12-20Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Load Short Form Nov 12, 2020Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Collins Residence, NisAir Air ConditioningFor: 5116 Silver Oaks Dr., Fort Pierce, FL 34983 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW8.6 Sensible cooling Btuh24220 Heating output Btuh29392 Latent cooling Btuh10380 Temperature rise °F23 Total cooling Btuh34600 Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.040 Air flow factor cfm/Btuh0.053 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.73 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Laundry 72 1648 1497 67 80 Bed 2 166 1964 1721 79 92 Kitchen 219 805 3377 32 180 Hall 58 0 0 0 0 Bed 3 157 2844 1570 115 84 Great Room 282 2288 3087 92 165 Dining Room 150 3432 1461 139 78 Foyer 85 1989 853 80 46 Wtr Clst 27 1227 752 50 40 WIC 1 29 37 25 1 1 WIC 2 29 674 245 27 13 M. Bath 145 2620 1057 106 57 Master Bed 279 5225 3774 211 202 Nook 94 2062 1530 83 82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N Bath 63 1752 634 71 34 House 1854 28566 21585 1153 1153 Other equip loads 2729 1449 Equip. @ 0.95 RSM 21974 Latent cooling 8460 TOTALS 1854 31295 30434 1153 1153 2021-Nov-11 13:26:32 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Building Analysis Nov 12, 2020Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Collins Residence, NisAir Air ConditioningFor: 5116 Silver Oaks Dr., Fort Pierce, FL 34983 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 17.855673.1Walls 16.7524017.9Glazing 000Doors 5.918381.0Ceilings 19.861933.33.3Floors 11.636372.1Infiltration 19.56092Ducts 00Piping 00Humidification 8.72729Ventilation0Adjustments 100.031295Total Cooling Walls Glazing Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 14.934301.9Walls 18.1416714.3Glazing 000Doors 4.911280.6Ceilings 000Floors 4.410160.6Infiltration 29.66823Ducts 6.31449Ventilation 21.85020Internal gains 00Blower 0Adjustments 100.023034Total Latent Cooling Load = 8460 Btuh Overall U-value = 0.112 Btuh/ft²-°F Data entries checked. 2021-Nov-11 13:26:32 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Component Constructions Nov 12, 2020Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Collins Residence, NisAir Air ConditioningFor: 5116 Silver Oaks Dr., Fort Pierce, FL 34983 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd inI, 8" Thk, 1/2" Gyp Bd Int Fnsh 7443.155.10.109236n 4762.02 7332.0211463.155.10.109364e 7872.0212313.155.10.109391s 9792.0215313.155.10.109486w 29752.0246523.155.10.1091476all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 4551.469152.9411.00.101312 Windows Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.16); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 9.8 ft overhang (1.25 ft window ht, 1 ft sep.); 8 ft head ht 689.0810714.200.4908n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (4.17 ft window ht, 1 ft sep.); 8 ft head ht 14711.722518.000.62013n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 9.8 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht 36611.756118.000.62031n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 15.9 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht 4188.7190518.800.65048n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (3.17 ft window ht, 1 ft sep.); 8 ft head ht 18628.111116.800.5807e 18628.111116.800.5807w 37128.122216.800.58013all 2021-Nov-11 13:26:32 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht 43928.126216.800.58016e 21313.626216.800.58016s 65220.952516.800.58031all Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 4 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht 21013.526216.800.58016s Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 12 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht 102810.7181018.800.65096s Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.17 ft window ht, 1 ft sep.); 8 ft head ht 60628.136216.800.58022w Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 5 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht 30019.326216.800.58016w Doors (none) Ceilings Attic, Metal Roof, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh 0.0341854 11280.6118380.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00619328.700.989216 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Project Summary Nov 12, 2020Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Collins Residence, NisAir Air ConditioningFor:5116 Silver Oaks Dr., Fort Pierce, FL 34983 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh22474 Structure Btuh14761 Ducts Btuh6092 Ducts Btuh6823Central vent (86 cfm) 2729 Btuh Central vent (86 cfm) Btuh1449 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh31295 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh21974 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3121 Ducts Btuh2030Central vent (86 cfm) Btuh3309 CoolingHeating Outside air18541854Area (ft²) Equipment latent load Btuh8460 1801718017Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh30434 Equiv. AVF (cfm) 60114 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond ML14XC1S036-230C**AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW8.6 Sensible cooling Btuh24220Heating output Btuh29392 Latent cooling Btuh10380 Temperature rise °F23 Total cooling Btuh34600Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.040 Air flow factor cfm/Btuh0.053Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.73 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Laundry 2 Exposed wall 215.9 ft 18.0 ft 3 Room height 9.7 ft 9.3 heat/coolft 4 Room dimensions ft6.0x12.0 5 Room area 1854.0 ft²72.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 335 236 744 476 0 0 0 0 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 8 0 107 68 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 13 0 225 147 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 31 0 561 366 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 48 0 905 418 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 386 364 1146 733 56 49 155 99 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 7 0 111 186 7 0 111 186 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 16 0 262 439 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 518 391 1231 787 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 16 13 262 213 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 16 16 262 210 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 96 96 1810 1028 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 530 486 1531 979 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 7 0 111 186 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 22 0 362 606 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 16 9 262 300 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 312 312 915 455 112 112 328 163 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 1854 1854 1838 1128 72 72 71 44 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 1854 216 6193 0 72 18 516 0 6 c) AED excursion 0 1 Envelope loss/gain 18838 8725 1181 492 12 a) Infiltration 3637 1016 115 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 4100 500 Subtotal (lines 6 to 13)22474 14761 1296 1024 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 22474 14761 1296 1024 15 Duct loads 27%46%6092 6823 27%46%351 473 Total room load 28566 21585 1648 1497 Air required (cfm)Air required (cfm)1153 1153 67 80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Kitchen 2 Exposed wall 15.0 ft 7.0 ft 3 Room height 9.3 heat/coolft 10.0 heat/coolft 4 Room dimensions ft166.0x1.0 ft17.5x12.5 5 Room area 166.0 ft²218.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 140 124 390 250 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 16 0 262 439 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 70 70 206 102 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 166 166 165 101 219 219 217 133 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 166 15 430 0 219 7 201 0 6 c) AED excursion 51 -91 Envelope loss/gain 1248 841 623 144 12 a) Infiltration 287 80 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 250 1700 Subtotal (lines 6 to 13)1534 1171 623 2304 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 11 6 10 6 14 Subtotal 1545 1177 633 2310 15 Duct loads 27%46%419 544 27%46%172 1068 Total room load 1964 1721 805 3377 Air required (cfm)Air required (cfm)79 92 32 180 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 3...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Hall Bed 3 2 Exposed wall 0 ft 24.0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft57.8x1.0 ft156.8x1.0 5 Room area 57.8 ft²156.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 102 102 322 206 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 121 105 332 212 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 0 0 0 0 16 13 262 213 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 58 58 57 35 157 157 155 95 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 58 0 0 0 157 24 688 0 6 c) AED excursion -1 -42 Envelope loss/gain 57 34 1760 684 12 a) Infiltration 0 0 459 128 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 250 Subtotal (lines 6 to 13)57 34 2219 1063 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -57 -34 19 11 14 Subtotal 0 0 2238 1074 15 Duct loads 27%46%0 0 27%46%607 496 Total room load 0 0 2844 1570 Air required (cfm)Air required (cfm)0 0 115 84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 4...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Great Room Dining Room 2 Exposed wall 9.5 ft 28.5 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft281.5x1.0 ft13.0x11.5 5 Room area 281.5 ft²149.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 115 76 240 154 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 0 0 0 0 8 0 107 68 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 31 0 561 366 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 95 47 148 95 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 48 48 905 514 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 40 40 126 81 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 130 130 382 190 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 282 282 279 171 150 150 148 91 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 282 10 272 0 150 29 817 0 6 c) AED excursion -84 -40 Envelope loss/gain 1604 697 2381 910 12 a) Infiltration 195 55 319 89 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)1800 2111 2700 999 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1800 2111 2700 999 15 Duct loads 27%46%488 976 27%46%732 462 Total room load 2288 3087 3432 1461 Air required (cfm)Air required (cfm)92 165 139 78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 5...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Foyer Wtr Clst 2 Exposed wall 9.0 ft 11.0 ft 3 Room height 10.0 heat/coolft 9.3 heat/coolft 4 Room dimensions ft85.0x1.0 ft27.3x1.0 5 Room area 85.0 ft²27.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 90 42 132 85 42 42 132 84 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 48 0 905 418 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 60 54 170 109 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 7 0 111 186 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 85 85 84 52 27 27 27 17 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 85 9 258 0 27 11 315 0 6 c) AED excursion -23 60 Envelope loss/gain 1380 531 755 455 12 a) Infiltration 185 52 210 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1565 583 965 514 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1565 583 965 514 15 Duct loads 27%46%424 270 27%46%262 238 Total room load 1989 853 1227 752 Air required (cfm)Air required (cfm)80 46 50 40 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 6...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name WIC 1 WIC 2 2 Exposed wall 0 ft 6.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft29.4x1.0 ft29.4x1.0 5 Room area 29.4 ft²29.4 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 60 60 190 122 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 29 29 29 18 29 29 29 18 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 29 0 0 0 29 7 186 0 6 c) AED excursion -1 -7 Envelope loss/gain 29 17 406 133 12 a) Infiltration 0 0 124 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)29 17 530 168 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 29 17 530 168 15 Duct loads 27%46%8 8 27%46%144 78 Total room load 37 25 674 245 Air required (cfm)Air required (cfm)1 1 27 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 7...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name M. Bath Master Bed 2 Exposed wall 22.4 ft 34.5 ft 3 Room height 9.3 heat/coolft 10.0 heat/coolft 4 Room dimensions ft145.0x1.0 ft279.0x1.0 5 Room area 145.0 ft²279.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 88 76 239 153 0 0 0 0 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 13 0 225 147 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 88 88 278 178 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 140 92 290 185 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 0 0 0 0 48 48 905 514 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 33 33 103 66 205 183 578 370 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 22 0 362 606 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 145 145 144 88 279 279 277 170 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 145 22 643 0 279 35 989 0 6 c) AED excursion -29 38 Envelope loss/gain 1631 603 3401 1882 12 a) Infiltration 430 120 709 198 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)2062 723 4110 2581 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2062 723 4110 2581 15 Duct loads 27%46%559 334 27%46%1114 1193 Total room load 2620 1057 5225 3774 Air required (cfm)Air required (cfm)106 57 211 202 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Nov-11 13:26:32Right-Suite® Universal 2021 21.0.08 RSU29066 Page 8...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Right-J® Worksheet Nov 12, 2020Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Nook Bath 2 Exposed wall 13.5 ft 17.0 ft 3 Room height 10.0 heat/coolft 9.3 heat/coolft 4 Room dimensions ft93.5x1.0 ft5.5x11.5 5 Room area 93.5 ft²63.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.490Impact, Clear Low-e 0.490 nn 14.2114.21 9.089.08 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 nn 17.9817.98 11.7411.74 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 8.718.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 55 39 124 79 107 107 337 216 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.6413.64 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 16 16 262 210 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ss 18.8518.85 10.7110.71 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 80 64 203 130 51 51 161 103 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 19.2519.25 16 9 262 300 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 94 94 93 57 63 63 63 38 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 94 14 387 0 63 17 488 0 6 c) AED excursion 185 -17 Envelope loss/gain 1332 961 1048 340 12 a) Infiltration 278 78 325 91 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1609 1039 1374 431 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 13 8 5 3 14 Subtotal 1622 1046 1379 434 15 Duct loads 27%46%440 484 27%46%374 201 Total room load 2062 1530 1752 634 Air required (cfm)Air required (cfm)83 82 71 34 2021-Nov-11 13:26:34 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Duct System Summary Nov 12, 2020Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Collins Residence, NisAir Air ConditioningFor: 5116 Silver Oaks Dr., Fort Pierce, FL 34983 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.439 / 0.261 in H2O in H2O0.439 / 0.261 Lowest friction rate in/100ft0.262in/100ft0.262 Actual air flow cfm1153cfm1153 Total effective length (TEL) ft267 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3125.038.9VlFx0x06.00.26841851752hBath st3125.042.6VlFx0x06.00.262110951721cBed 2 st3125.040.5VlFx0x07.00.2651011382844hBed 3 75.06.1VlFx0x06.00.541941663432hDining Room st295.023.2VlFx0x06.00.37255961989hFoyer st295.021.7VlFx0x06.00.37699551543cGreat Room st295.031.3VlFx0x06.00.34899551543cGreat Room-A st1100.017.2VlFx0x06.00.375108191689cKitchen st1100.018.9VlFx0x06.00.369108191689cKitchen-A st1100.018.8VlFx0x06.00.36996801497cLaundry st4115.036.2VlFx0x06.00.290681272620hM. Bath st4115.042.5VlFx0x06.00.2791211272612hMaster Bed st4115.032.8VlFx0x06.00.2971211272612hMaster Bed-A st3125.038.2VlFx0x06.00.269981002062hNook st4115.033.1VlFx0x04.00.2972237hWIC 1 st4115.035.6VlFx0x04.00.2921633674hWIC 2 st4115.041.1VlFx0x05.00.28148591227hWtr Clst Bold/italic values have been manually overridden 2021-Nov-11 13:26:34 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 2 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 418 350 0.262 766 10.0 0x0 VinlFlx st1 st1 Peak AVF 537 662 0.262 843 12.0 0x0 VinlFlx st2 Peak AVF 681 628 0.279 867 12.0 0x0 VinlFlx st4 Peak AVF 474 375 0.279 869 10.0 0x0 VinlFlx st2 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb4 0x 2880 259 99.5 0.262 527 10.0 x0 0 VlFx rt1 rb2 0x 950 110 72.0 0.362 562 6.0 x0 0 VlFx rt1 rb3 0x 1380 101 71.1 0.367 516 7.0 x0 0 VlFx rt1 rb1 0x 8630 914 72.2 0.361 517 18.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 1384 1384 0.262 783 18.0 0x0 VinlFlx 2021-Nov-11 13:26:34 Right-Suite® Universal 2021 21.0.08 RSU29066 Page 1 ...rightsoft HVAC\5116 Silver Oaks Dr PSL Prop.rup Calc = MJ8 Front Door faces: N 1373Job:Manual S Compliance Report Nov 12, 2020Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Collins Residence, NisAir Air ConditioningFor: 5116 Silver Oaks Dr., Fort Pierce, FL 34983 Cooling Equipment Design Conditions °F77.3Entering coil DB:Btuh23034Sensible gain:°F90.4Outdoor design DB: °F64.5Entering coil WB:Btuh8460Latent gain:°F77.4Outdoor design WB: Btuh31493Total gain:°F75.0Indoor design DB: cfm1153Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: ML14XC1S036-230C**+CBA27UHE-036-230*++TDRModel:LennoxManufacturer: cfm1153Actual airflow: % of load105Btuh24220Sensible capacity: % of load123Btuh10380Latent capacity: %70SHR:% of load110Btuh34600Total capacity: Heating Equipment Design Conditions °F67.3Entering coil DB:Btuh31295Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1153Actual airflow: °F50Temp. rise:% of load94kW8.6Output capacity: Meets all requirements of ACCA Manual S.