Loading...
HomeMy WebLinkAboutAPPROVED Product Approval underlaymentsl BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL37784-R1 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Mule-Hide Products Co., Inc. Address/Phone/Email 1195 Prince Hall Dr Beloit, WI 53511-5481 (608) 365-3111 Ext 809 lindar@nemoetc.com Authorized Signature Timothy McFarland lindar@nemoetc.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL37784_R1_COI_MHP21001.2a 2020 FBC Eval Underlayments final.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D 1623 2017 ASTM D 1970 2015 ASTM D 2626 2004 ASTM D 4601 2004 TAS 103 2020 TAS 110 2000 UL 1897 2012 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/13/2021 Date Validated 06/10/2021 Date Pending FBC Approval 04/22/2021 Date Approved 06/14/2021 Date Revised 08/12/2021 Summary of Products FL #Model, Number or Name Description 37784.1 Base Sheets Shur-Gard #40 Base Sheet, ASTM D 2626, & F/G Base Sheet, ASTM D 4601, Type II Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL37784_R1_II_MHP21001.2b 2020 FBC Eval Underlayments final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL37784_R1_AE_MHP21001.2b 2020 FBC Eval Underlayments final.pdf Created by Independent Third Party: Yes 37784.2 Shur-Gard Underlayments ASTM D 1970 self-adhered underlayments Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-90 Other: See evaluation report for limits of use. Installation Instructions FL37784_R1_II_MHP21001.2a 2020 FBC Eval Underlayments final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL37784_R1_AE_MHP21001.2a 2020 FBC Eval Underlayments final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a CREEK Technical Services, LLC MHP21001.2b FL37748-R1 Page 1 of 3 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Registry No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: MULE-HIDE PRODUCTS CO., INC. Issued June 9, 2021 1195 Prince Hall Dr Beloit, WI 53511 (800) 786-1492 www.mulehide.com Manufacturing Plants: Pryor, OK Quality Assurance: Keystone Certifications ,Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) Code Sections: 1507.1.1, 1518.4, 1523.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) GAPF-009-02-01 ASTM D 4601 TAS 110 2004(2012)E1 2000 PRI Construction Materials Technologies (TST5878) GAPR-013-02-01 ASTM D 2626 TAS 110 2004(2012)E1 2000 PRI Construction Materials Technologies (TST5878) 1047T0039 ASTM D 2626 TAS 110 2004(2012)E1 2000 aA CREEK Technical Services, LLC MHP21001.2b FL37748-R1 Page 2 of 3 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 MULE-HIDE PRODUCTS Underlayments PRODUCT DESCRIPTION Shur-Gard #40 Base Sheet Shur-Gard #40 Base Sheet is an ASTM D 2626 underlayment constructed of asphalt-saturated felt that is coated on both sides with weathering grade asphalt and surfaced with mineral surface fines. F/G Base Sheet F/G Base Sheet is an ASTM D 4601, Type II underlayment constructed of a fiberglass mat that is coated on both sides with weathering grade asphalt and surfaced with white sand fines. For use in the non-HVHZ only. APPLICATION Installation shall be in accordance with the published manufacturer’s installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8” gap at abutting joints. Shur-Gard #40 Base Sheet is permitted to be used as the base sheet in a two-ply underlayment in accordance with FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition, RAS 118, RAS 119, or RAS 120. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. Exception, Shur-Gard #40 Base Sheet may in used in adhered tile applications when used as the base sheet in a two -ply underlayment as permitted by code, and as approved in the cap sheet or tile roofing product approval. aA CREEK Technical Services, LLC MHP21001.2b FL37748-R1 Page 3 of 3 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 MULE-HIDE PRODUCTS Underlayments LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Roof slope limitations shall be in accordance with FBC requirements. 5) Underlayments may be used as described in other current FBC product approval documents. 6) Underlayments without granule surfacing shall not be exposed on the roof deck for greater than 30 days. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distri buting products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT This item has been digitally signed and sealed by Zachary R. Priest, PE, on 6/9/2021. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.