HomeMy WebLinkAboutAPPROVED Product Approval underlaymentsl
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL37784-R1
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Mule-Hide Products Co., Inc.
Address/Phone/Email 1195 Prince Hall Dr
Beloit, WI 53511-5481
(608) 365-3111 Ext 809
lindar@nemoetc.com
Authorized Signature Timothy McFarland
lindar@nemoetc.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Zachary R. Priest
Florida License PE-74021
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/31/2024
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL37784_R1_COI_MHP21001.2a 2020 FBC Eval Underlayments final.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D 1623 2017
ASTM D 1970 2015
ASTM D 2626 2004
ASTM D 4601 2004
TAS 103 2020
TAS 110 2000
UL 1897 2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/13/2021
Date Validated 06/10/2021
Date Pending FBC Approval 04/22/2021
Date Approved 06/14/2021
Date Revised 08/12/2021
Summary of Products
FL #Model, Number or Name Description
37784.1 Base Sheets Shur-Gard #40 Base Sheet, ASTM D 2626, & F/G Base Sheet,
ASTM D 4601, Type II
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL37784_R1_II_MHP21001.2b 2020 FBC Eval Underlayments
final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL37784_R1_AE_MHP21001.2b 2020 FBC Eval Underlayments
final.pdf
Created by Independent Third Party: Yes
37784.2 Shur-Gard Underlayments ASTM D 1970 self-adhered underlayments
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +0/-90
Other: See evaluation report for limits of use.
Installation Instructions
FL37784_R1_II_MHP21001.2a 2020 FBC Eval Underlayments
final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL37784_R1_AE_MHP21001.2a 2020 FBC Eval Underlayments
final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
a CREEK
Technical Services, LLC
MHP21001.2b FL37748-R1 Page 1 of 3 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
Registry No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020)
Manufacturer: MULE-HIDE PRODUCTS CO., INC. Issued June 9, 2021
1195 Prince Hall Dr
Beloit, WI 53511
(800) 786-1492
www.mulehide.com
Manufacturing Plants: Pryor, OK
Quality Assurance: Keystone Certifications ,Inc. (QUA1824)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Edition: Florida Building Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ)
Code Sections: 1507.1.1, 1518.4, 1523.1.1
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies (TST5878) GAPF-009-02-01 ASTM D 4601
TAS 110
2004(2012)E1
2000
PRI Construction Materials Technologies (TST5878) GAPR-013-02-01 ASTM D 2626
TAS 110
2004(2012)E1
2000
PRI Construction Materials Technologies (TST5878) 1047T0039 ASTM D 2626
TAS 110
2004(2012)E1
2000
aA CREEK
Technical Services, LLC
MHP21001.2b FL37748-R1 Page 2 of 3 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
MULE-HIDE PRODUCTS
Underlayments
PRODUCT DESCRIPTION
Shur-Gard #40 Base
Sheet
Shur-Gard #40 Base Sheet is an ASTM D 2626 underlayment constructed of
asphalt-saturated felt that is coated on both sides with weathering grade asphalt
and surfaced with mineral surface fines.
F/G Base Sheet F/G Base Sheet is an ASTM D 4601, Type II underlayment constructed of a
fiberglass mat that is coated on both sides with weathering grade asphalt and
surfaced with white sand fines.
For use in the non-HVHZ only.
APPLICATION
Installation shall be in accordance with the published manufacturer’s installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8” gap at abutting
joints.
Shur-Gard #40 Base Sheet is permitted to be used as the base sheet in a two-ply underlayment in accordance with
FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition, RAS 118, RAS 119, or RAS
120.
Roof coverings shall be mechanically fastened through the underlayment to the roof deck. Exception, Shur-Gard
#40 Base Sheet may in used in adhered tile applications when used as the base sheet in a two -ply underlayment as
permitted by code, and as approved in the cap sheet or tile roofing product approval.
aA CREEK
Technical Services, LLC
MHP21001.2b FL37748-R1 Page 3 of 3 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
MULE-HIDE PRODUCTS
Underlayments
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Roof slope limitations shall be in accordance with FBC requirements.
5) Underlayments may be used as described in other current FBC product approval documents.
6) Underlayments without granule surfacing shall not be exposed on the roof deck for greater than 30 days.
7) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distri buting
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
This item has been
digitally signed and
sealed by Zachary R.
Priest, PE, on 6/9/2021.
Printed copies of this
document are not
considered signed and
sealed and the signature
must be verified on any
electronic copies.