Loading...
HomeMy WebLinkAboutAPPROVED, 5015 Seagrape Dr Permit info sheet�T'Y LEI LLL i' L iL — -1— ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW,. Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,8,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, 8, D 1,43,4,5,6,,7 Wood Shingles and Shakes A, B, D t,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE °.:'V()� �K=1 Section A (General Information) Master Permit No. Process No. Contractors Name: Collins Roofing Inc. License a CCC-058011 4 Job Add ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mar-tar/Adhesive Set Tiles ❑Asphaltic Shingles V etal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE // ❑ � New roof ❑ Repair ❑ Maintenance Reroofing ❑Recovering �� ROOF SYSTEM INFORMATION /�' Low Slope Roof Area (SF) `��.3 —> Steep Sloped Roof Area (SF) i U D O L 4 Total (SF) � tI. Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. I" ri MMM ■EEC ■m - ST. LUCIE WORKS Section D (Steep Slope Roof System) Extreme Metal Fab Roof System manufacturer, Notice of Acceptance Number: FL 17023 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 81.7 Zone 1:�Zone 205—Zone 2n1�Zone 2rZ�S'one 3e: Zane 3r: Deck Type: 5/8" Plywood Type Underlayment i High Temp/Self Adhesive Underlayment-Mu� DE Roof Slope: 12 Insulation: N/A Fire Bamer: N/A REdge Ventilation? Fastener Type & Spacing: #10x1.5"-12"x12" Pattern 16" o.c. (Wood Zac) NIA Adhesive Type: NIA \ Type Cap Sheet NIA I Mean RoofeHH ight: 15 ft \ Roof Covering: 26 Ga 5V Metal Roof Panels Type & Size Drip 2"x2" Galy. Steel . Edge: ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: POlyglass Product Approval No,: FL 1654 _ Z `j Design wind Pressures, From RAS 128 Or Calculations: 53. -53 3 -74A -95.8 Zone 1': � one 1: Zone 2: _Zone 3: Max. Design Pressure, from the specific product approval system Deck: Type: Plywood Gauge Thickness 5/8" Slope: 1-V2 112 Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material. Insulation Base Layer. Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material - Top Insulation Layer Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s) Polyglass SA-V & 1 Base Sheet Fastener/Bonding Material: Self -Adhesive Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Self -Adhesive �(_-) d- Surfacing White Granular Surfaces Fastener Spacing for Anchor/Base Sheet Attachment Zone 1':_." oc @ Lap, # Rows— ® _ _"oo Zone 1:_" oc @ Lap, # Rows — @ oc Zone 2:—" oc @ Lap, # Rows — @ —" cc Zone 3:—" cc @ Lap, # Rows @ —" cc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2• Zone 3: Illustrate Components Noted and Details as Applicable: woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.