Loading...
HomeMy WebLinkAboutAPPROVED, 5V Metal1/20/21, 4:21 PMFlorida Building Code Online Page 1 of 6https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvVo%2boyCRf2R7TKjFN18fT4mLrB7XkLU%2bI%3d BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL4595-R5 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Tri County Metals Address/Phone/Email 301 SE 16th Street Trenton, FL 32693 (352) 463-8400 testing@tricountymetals.com Authorized Signature Jason Klinkenberg testing@tricountymetals.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Johnathan E. Green, P.E. Florida License PE-88223 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 06/02/2024 Validated By Brian Jaks, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL4595_R5_COI_Letter of Certification- Tri County Metals._sealed.pdf Referenced Standard and Year (of Standard)Standard Year FM 4471 1992 UL 1897 2012 UL 580 2006 1/20/21, 4:21 PMFlorida Building Code Online Page 2 of 6https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvVo%2boyCRf2R7TKjFN18fT4mLrB7XkLU%2bI%3d Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/13/2020 Date Validated 10/23/2020 Date Pending FBC Approval 10/28/2020 Date Approved 12/15/2020 Summary of Products FL #Model, Number or Name Description 4595.1 5V Crimp Min. 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -78.5 psf @ 16" o.c. Fastener Spacing. -101.0 psf @ 16" o.c. Fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.1 26 Ga. 5V Crimp Panel over Plywood_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.1 26 Ga. 5V Crimp Panel over Plywood_sealed.pdf Created by Independent Third Party: Yes 4595.2 5V Crimp Min. 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -78.5 psf @ 16" o.c. Fastener Spacing. -101.0 psf @ 16" o.c. Fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.2 26 Ga. 5V Crimp Panel over 1x4 NON HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.2 26 Ga. 5V Crimp Panel over 1x4 NON HVHZ_sealed.pdf Created by Independent Third Party: Yes 4595.3 Aluminum Mechanical-Seam Lok .032" Aluminum Mechanical Lock 16" Wide Roof Panel over Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 psf Other: -78.5 psf @ 18" o.c. clip spacing. -93.5 psf 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.3 Aluminum Mechanical-Seam Lok 1.5 over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.3 Aluminum Mechanical-Seam Lok 1.5 over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes 4595.4 Aluminum Mechanical-Seam Lok 2".032" Aluminum, 2" Mechanical Lock, 19" Wide Roof Panel over 22 Ga. Steel Deck Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5psf Other: -71.0 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.4 Aluminum Mechanical-Seam Lok 2 over Steel Deck HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.4 Aluminum Mechanical-Seam Lok 2 over Steel Deck HVHZ_sealed.pdf Created by Independent Third Party: Yes 1/20/21, 4:21 PMFlorida Building Code Online Page 3 of 6https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvVo%2boyCRf2R7TKjFN18fT4mLrB7XkLU%2bI%3d 4595.5 Aluminum TCM Lok 0.032" Aluminum TCM Lok Roof Panel over 7/16" OSB or 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-112.5psf Other: -75.0 psf at 4 1/2" o.c. fastener spacing. -112.5 psf at 4 1/2" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.5 Aluminum TCM Lok over Plywwod_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.5 Aluminum TCM Lok over Plywwod_sealed.pdf Created by Independent Third Party: Yes 4595.6 Mechanical-Seam Lok 1-½"1-½" Mechanical Lock, 24 Ga., 16" Wide Roof Panel over Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5psf Other: -59.75 psf. @ 24" o.c. clip spacing. -123.5 psf. @ 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.6 Mechanical-Seam Lok 1.5 over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.6 Mechanical-Seam Lok 1.5 over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes 4595.7 Mechanical-Seam Lok 2"2" Mechanical Lock, 24 Ga. Steel, 18-7/8" Wide Roof Panel over 22 Ga. Steel Deck Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -54.3 psf @ 36" o.c. clip spacing. -153.5 psf @ 6" o.c. clip spacing. Install per manufacturer's details. For use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.7 Mechanical-Seam Lok 2 24 Ga. over Steel Deck HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.7 Mechanical-Seam Lok 2 24 Ga. over Steel Deck HVHZ_sealed.pdf Created by Independent Third Party: Yes 4595.8 Nail Strip 1"1" Nailstrip, 24 Ga. Steel 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5psf Other: -153.5 psf @ 6-3/4" o.c. Fastener Spacing in slot and 12" o.c. Fastener Spacing in pan. -101.0 psf @ 6-3/4" o.c. Fastener Spacing in slot. -59.75 psf @ 16 o.c. Fastener Spacing in slot. Install per Manufacturer's Details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.8 1in Nail Strip over Plywood_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.8 1in Nail Strip over Plywood_sealed.pdf Created by Independent Third Party: Yes 4595.9 Nail Strip 1-½"1-½" Nail Strip, 24 Ga. 15-½" Wide Roof Panel over Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -116.0 psf @ 6-1/2" o.c. Fastener Spacing in slot and 12" o.c. Fastener Spacing in pan. -78.5 psf @ 11" o.c. Fastener Spacing in slot. Install per Manufacturer's Details. For use in HVHZ Zones Installation Instructions FL4595_R5_II_FL 4595.9 1.5 Nailstrip 24 Ga. over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.9 1.5 Nailstrip 24 Ga. over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes 4595.10 PBR Min. 26 Ga. PBR Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 PSF Other: -63.5 psf @ 24" o.c. Fastener Spacing. -93.5 psf @ 24" o.c. Fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.10 26 Ga. PBR Panel over Plywood_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.10 26 Ga. PBR Panel over Plywood_sealed.pdf 1/20/21, 4:21 PMFlorida Building Code Online Page 4 of 6https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvVo%2boyCRf2R7TKjFN18fT4mLrB7XkLU%2bI%3d Created by Independent Third Party: Yes 4595.11 PBR Min. 26 Ga. PBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 PSF Other: -71.0 psf @ 24" o.c. Fastener Spacing. -78.5 psf @ 24" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.11 26 Ga. PBR Panel over 1x4_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.11 26 Ga. PBR Panel over 1x4_sealed.pdf Created by Independent Third Party: Yes 4595.12 Snap-Lok 1-½"1-½" Snap Lok, 24 Ga. , 16" Wide Roof Panel over Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0psf Other: -108.5 psf @12" o.c. Clip spacing. -86.0 psf @ 24" o.c. Clip Spacing. -116.0 psf @ 6" o.c. Clip Spacing. Install per Manufacturer's Details. For use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.12 1.5 Snap Lock 24 Ga. over Plywood HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.12 1.5 Snap Lock 24 Ga. over Plywood HVHZ_sealed.pdf Created by Independent Third Party: Yes 4595.13 Snap-Lok 1-¾"1-¾" Snap Lock, 24 Ga. Steel, 17-¾" Wide Roof Panel over 22 Ga. Steel Decking Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5psf Other: -71.0 psf @ 24" o.c. Clip Spacing. -108.5 psf @ 6" o.c. Clip Spacing. Install per manufacturer's details. For use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.13 Snap-Lok 1.75 24 Ga. over Steel Deck HVHZ_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.13 Snap-Lok 1.75 24 Ga. over Steel Deck HVHZ_sealed.pdf Created by Independent Third Party: Yes 4595.14 TCM-Lok Min. 24 Ga. TCM-Lok Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -116.0 psf @ 5 1/4" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.14 TCM-Lok Eval Report_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.14 TCM-Lok Eval Report_sealed.pdf Created by Independent Third Party: Yes 4595.15 Ultra-Rib Min. 29 Ga. Ultra-Rib Roof Panel over 15/32” Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -84.3 psf @ 24"o.c.fastener spacing. -146.0 psf @ 12" o.c. fastener spacing. Install per manufacturer's installation details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.15 29 Ga. Ultra-Rib Panel over Plywood_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.15 29 Ga. Ultra-Rib Panel over Plywood_sealed.pdf Created by Independent Third Party: Yes 4595.16 Ultra-Rib Min. 29 Ga. Ultra Rib, 36" wide, Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -93.5 psf @ 24" o.c. fastener spacing. -138.5 psf @ 24" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.16 29 Ga. Rib Panel over 1x4_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.16 29 Ga. Rib Panel over 1x4_sealed.pdf Created by Independent Third Party: Yes 1/20/21, 4:21 PMFlorida Building Code Online Page 5 of 6https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvVo%2boyCRf2R7TKjFN18fT4mLrB7XkLU%2bI%3d 4595.17 Ultra-Rib Min. 29 Ga. Ultra Rib, 36" wide, Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0PSF Other: -78.5 psf @ 24" o.c. fastener spacing. -86.0 psf @ 24" o.c. fastener spacing. Install per manufactuer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.17 29 Ga. Rib Panel over 1x4 with shingles_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.17 29 Ga. Rib Panel over 1x4 with shingles_sealed.pdf Created by Independent Third Party: Yes 4595.18 Ultra-Rib Min. 29 Ga. Ultra-Rib Roof Panel over 7/16" OSB Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -41.7 psf @ 24" o.c. fastener spacing. -123.5 psf @ 12" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.18 29 Ga. Ultra-Rib Panel over OSB_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.18 29 Ga. Ultra-Rib Panel over OSB_sealed.pdf Created by Independent Third Party: Yes 4595.19 Ultra-Rib 29 Ga. Ultra-Rib Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -63.5 psf @ 24" o.c. - 101.0 psf @ 24" o.c. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.19 29 Ga. Ultra-Rib Panel over Plywood with shingles_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.19 29 Ga. Ultra-Rib Panel over Plywood with shingles_sealed.pdf Created by Independent Third Party: Yes 4595.20 Ultra-Rib 29 Ga. Ultra-Rib Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0PSF Other: -52.5 psf @ 24" o.c. fastener spacing. -131.0 psf @ 6" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. Installation Instructions FL4595_R5_II_FL 4595.20 29 Ga. Ultra Rib Panel over 1x4 with shingles_sealed.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL4595_R5_AE_FL 4595.20 29 Ga. Ultra Rib Panel over 1x4 with shingles_sealed.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 1/20/21, 4:21 PMFlorida Building Code Online Page 6 of 6https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvVo%2boyCRf2R7TKjFN18fT4mLrB7XkLU%2bI%3d FL# 4595.1 R5 Product Evaluation Report TRI COUNTY METALS Min. 26 Ga. 5V Crimp Roof Panel over 15/32” Plywood Florida Product Approval # 4595.1 R5 Florida Building Code 2020 Per Rule 61G20-3 Method: 1 –D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Tri County Metals 301 SE 16th Street Trenton, Florida 32693 Engineer Evaluator: Johnathan Green, P.E. #88223 Florida Evaluation ANE ID: 12901 Validator: Brian Jaks P.E. #70159 Contents: Evaluation Report Pages 1 – 4 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 01 2020 FL# 4595.1 R5 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2020, Sections 1504.3.2, 1504.7. Product Description: 5V Crimp Roof Panel, Min. 26 Ga. Steel, Ϯϰ͟ coǀerage, through fastened roof panel over Min. 15/32͟ APA Plywood decking. Non-structural Application. Panel Material/Standards: Material: Min. 26 Ga. Steel, conforming to Florida Building Code 2020 Section 1507.4.3. Paint finish optional. Yield Strength: Min. 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2020, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018͟ min. Width: Ϯϰ͟ maximum coverage Rib Height: ϯͬϴ͟ tall ribs Panel Fastener: #9-15 x 1-ϭͬϮ͟ Woodgrip with sealing washing or approved equal Ь͟ minimum penetration through plywood Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4. Substrate Description: Min. 15/32͟ thick, APA Rated plywood over supports at madžimƵm Ϯϰ͟ O͘C͘ Design of plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/ Florida Building Code 2020. Allowable Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure: 78.5 psf 101.0 psf Fastener Pattern: 12͟-12͟ 10͟-Ϯ Ъ͟-10͟ Fastener Spacing: 16͟ O.C. 16͟ O.C. *Design Pressure includes a Safety Factor = 2.0. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 01 2020 FL# 4595.1 R5 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2020, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2020, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ƒ UL 580-06 - Test for Uplift Resistance of Roof Assemblies ƒ UL 1897-2012 - Uplift Test for Roof Covering Systems ƒ FM 4471-92 - Foot Traffic Resistance Test Reference Data: 1. UL 580-06 / 1897-04 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 136-0172T-12 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 136-0172T-12 3. Certificate of Independence By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing (FBC Organization # ANE ID: 12901) Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard. The FM 4471-10, Foot Traffic Resistance test standard is equivalent to the FM 4471-92, Foot Traffic Resistance test standard Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per manufacturer͛s recommended details. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 01 2020 FL# 4595.1 R5 Underlayment: Per Florida Building Code 2020, Section 1507.1.1 and manƵfactƵrer͛s installation guidelines. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2020 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2020 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 01 2020 FL# 4595.1 R5 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JOHNATHAN GREEN ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.OCT 01 2020