HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION - FINAL APPROVALSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
PERMIT #:
DATE PAID:
FEE PAID:
RECEIPT #:
230.00
56-SF-2353498
DOCUMENT #:FI1733264
AP1715938APPLICATION #:
56-PID-5175424
08/23/2021
LOT:
ID#:
BLOCK:
SUBDIVISION:Seminole Park
APPLICANT:TD Enterprises FL LLC
AGENT:MICHAEL STUHR (ASHTON SEPTIC TANKS, INC.)
PROPERTY ADDRESS:2504 Kerr St Fort Pierce, FL 34947
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
[01] TANK SIZE[][1]1090.00 [2]300.00
[02] TANK MATERIAL[]Polypropylene
[03] OUTLET DEVICE[]
[04] MULTI-CHAMBERED[][Y ]N/
[05] OUTLET FILTER[]
[06] LEGEND[]
[07] WATERTIGHT[]
[08] LEVEL[]
[09] DEPTH TO LID[]
TANK INSTALLATION
[27] SURFACE WATER[]
SETBACKS
FT
[28] DITCHES[]FT
[29] PRIVATE WELLS[]78 FT
[30] PUBLIC WELLS[]FT
[31] IRRIGATION WELLS[]FT
[32] POTABLE WATER []25 FT
[33] BUILDING FOUNDATIONS[]5 FT
[34] PROPERTY LINES[]14 FT
[35] OTHER[]FT
[10] AREA[][1]509.4 [2]
[11] DISTRIBUTION[]
[12] NUMBER OF DRAINLINES[]
[13] DRAINLINE SEPARATION[]
[15] DEPTH OF COVER[]
[16] ELEVATION []
[17] SYSTEM LOCATION[]
[18] DOSING PUMPS[]
[19] AGGREGATE SIZE[]
DRAINFIELD INSTALLATION
SQFT
BOX HEADER X
[BELOW ]BMABOVE/11.00
[14] DRAINLINE SLOPE[]
1.00
[20] AGGREGATE EXCESSIVE FINES[]
[21] AGGREGATE DEPTH[]
[36] DRAINFIELD COVER[]
FILLED / MOUND SYSTEM
[37] SHOULDERS[]
[38] SLOPES[]
[39] STABILIZATION[]11/03/2021
[40] UNOBSTRUCTED AREA[]
ADDITIONAL INFORMATION
[41] STORMWATER RUNOFF[]
[42] ALARMS[]
[43] MAINTENANCE AGREEMENT[]
[44] BUILDING AREA[]
[45] LOCATION CONFORMS WITH SITE PLAN[]
[46] FINAL SITE GRADING[]
[47] CONTRACTOR[]MICHAEL W STUHR (ASHTO
[48] OTHER[]INFILTRATOR Quick4 Plus EQ36 LP
[49] TANK PUMPED[]
ABANDONMENT
[50] TANK CRUSHED & FILLED[]
10/27/2021
[22] FILL AMOUNT[]
FILL / EXCAVATION MATERIAL
[23] FILL TEXTURE[]
[24] EXCAVATION DEPTH[]
[25] AREA REPLACED[]
[26] REPLACEMENT MATERIAL[]
Polylok PL-68
1.2.
1.2.
70-156-03SC3
6.00
70-143-11DC4
9 1
2419-601-0010-000-0
Comments are on page 2.
10/27/2021
Comments:
CONSTRUCTION []:/CHD DATE:
DISAPPROVED
St. Lucie 10/27/2021APPROVED
Environmental Specialist III Brian J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM []:/CHD DATE:DISAPPROVED St. Lucie 11/03/2021
Environmental Specialist III Brian J Ingram (ENVIRONMENTAL HEALTH)
APPROVED
(Explanation of Violations on following page)
EH Database v 1.0.1 AP1715938 EID2353498
Page 2 of 3
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
PERMIT #:
DATE PAID:
FEE PAID:
RECEIPT #:
230.00
56-SF-2353498
DOCUMENT #:FI1733264
AP1715938APPLICATION #:
56-PID-5175424
08/23/2021
Violation Number Comment
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300
gpd.
Existing ST pumped and abandoned. No violations, abandonment approved.
New ST, filter, DT, liberty 1/3 hp pump, and 3x7+3x8 long BED DF installed. No violations, system ok to cover, contractor notified
onsite. Needs final inspection for mound system and final site grading.
Final system approved. Contractor and building department emailed final approval.
Comments
EH Database v 1.0.1 AP1715938 EID2353498
Page 2 of 3
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC