HomeMy WebLinkAboutAPPROVED ADAMS RANCH_237546_16280499_Structural Analysis_09-09-2021June 15, 2021 FL COA# 31011
John Scandura Tower Engineering Professionals
Verizon Wireless 326 Tryon Road
4700 Exchange Court, Suite 100 Raleigh, NC 27603
Boca Raton, FL 33431 (919) 661-6351
SDD@tepgroup.net
Subject: Structural Modification Analysis Report
Verizon Wireless Designation: Carrier Site Number: 237546
Carrier Site Name: Adams Ranch
Engineering Firm Designation: TEP Project Number: 152906.551427
Site Data: 21715 Orange Avenue, Fort Pierce, St. Lucie County, FL 34945
Latitude 27° 26' 26.79”, Longitude -80° 32' 51.31”
300 Foot - Guyed Tower
Dear John Scandura,
Tower Engineering Professionals is pleased to submit this “Structural Modification Analysis Report” to
determine the structural integrity of the above mentioned tower.
The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have
determined the tower stress level for the structure and foundation, under the following load case, to be:
LC2: Existing + Proposed + Reserved Loading with Proposed Modifications Sufficient Capacity
Note: See Table 1 for the existing and proposed loading
The analysis has been performed in accordance with the ANSI/TIA-222-H Structural Standard for Antenna
Supporting Structures, Antennas, and Small Wind Turbine Support Structures and the 2020 Florida Building Code,
7th Edition.
All modifications and equipment proposed in this report shall be installed in accordance with the appurtenances
listed in Table 1 and attached drawings for the determined available structural capacity to be effective.
We at Tower Engineering Professionals appreciate the opportunity of providing our continuing professional
services to you and Verizon Wireless. If you have any questions or need further assistance on this or any other
projects, please give us a call.
Structural analysis prepared by: Jessica Moebs, P.E. / ECL
Respectfully submitted by:
Shawn Hoffmeyer, P.E.
Structure Capacity Foundation Capacity
97.2% 49.0%
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 2
tnxTower report - version 8.1.1.0
TABLE OF CONTENTS
1) INTRODUCTION
2) ANALYSIS CRITERIA
Table 1 - Existing and Proposed Antenna and Cable Information
3) ANALYSIS PROCEDURE
Table 2 - Documents Provided
3.1) Analysis Method
3.2) Assumptions
4) ANALYSIS RESULTS
Table 3 - Section Capacity (Summary)
Table 4 - Tower Component Stresses vs. Capacity
4.1) Recommendations
5) APPENDIX A
tnxTower Output
6) APPENDIX B
Additional Calculations
7) APPENDIX C
Structural Design Drawings
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 3
tnxTower report - version 8.1.1.0
1) INTRODUCTION
This tower is a 300-ft guyed tower design by Rohn and mapped by Tower Engineering Professionals in June of
2019. The tower has been modified multiple times in the past to accommodate additional loading. All information
provided to TEP was to be assumed accurate and complete.
2) ANALYSIS CRITERIA
TIA-222 Revision: TIA-222-H
Risk Category: II
Wind Speed: 153 mph
Exposure Category: C
Topographic Factor: 1.0
Service Wind Speed: 60 mph
Table 1 - Existing and Proposed Antenna and Cable Information
Existing/
Proposed/
Reserved
Mount
Level
(ft)
Ant
CL
(ft)
Qty Antenna Model Mount
Type
Qty
Coax
Coax
Size
Coax
Location
Owner/
Tenant
Existing 297.0 306.0 1 BCD-80612 6’ Standoff 1 1-5/8 AB Face Verizon
Proposed 284.8 288.0
3 Ericsson VZE01
12.5-ft Sector
Mount w/
Modifications
2 12x24
Hybrid CA Face Verizon 3 Ericsson 4449 B5/B13
3 Ericsson 8843 B2/B66A
2 Raycap RHSDC-6627-PF-48
Existing 284.8 288.0
6 CSS Antenna
X7CQAP-665-V 14 1-5/8 CA Face Verizon
3 JMA Wireless
DBC-67C-U-1SF
To Be
Removed 284.8 288.0 3 Antel X7-666-4 - - - - Verizon
Existing 127.0 127.0 1 Andrew UHX6-59-P3A/L-P Pipe Mount 1 EW63 CA Face Verizon
Existing 115.0 115.0 1 Andrew P4-57W-PXA/A Pipe Mount 1 EW63 AB Face Verizon
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 4
tnxTower report - version 8.1.1.0
3) ANALYSIS PROCEDURE
Table 2 - Documents Provided
Document Remarks Source
Tower Reinforcement
Drawings Excell Communications, Inc., dated February 2, 2010 Verizon
Tower Reinforcement
Drawings
Kimley-Horn and Associates, Inc., dated September 1, 2016
KHA Job #: 044048141 Verizon
Tower Mapping Report Tower Engineering Professionals dated June 11, 2019
TEP No: 152906.261285 Verizon
Structural Analysis Report CBVR Telecom Design Group, dated June 26, 2019
CBVR Project Number: VZW.072.19 Verizon
Previous Structural Analysis Tower Engineering Professionals dated April 16, 2021
TEP No: 152906.498968 TEP
Correspondence Correspondence from Verizon Wireless in reference to the
existing, proposed, and reserved loading. Verizon
3.1) Analysis Method
tnxTower (version 8.1.1.0), a commercially available analysis software package, was used to create a
three-dimensional model of the tower and calculate member stresses for various loading cases.
Selected output from the analysis is included in Appendix A.
3.2) Assumptions
1) The tower and foundation were built in accordance with the manufacturer’s specifications.
2) The tower and foundation have been maintained in accordance with the manufacturer’s
specification.
3) All tower components are in sufficient condition to carry their full design capacity.
4) Serviceability with respect to antenna twist, tilt, roll, or lateral translation, is not checked and is
left to the carrier or tower owner to ensure conformance.
5) All antenna mounts and mounting hardware are structurally sufficient to carry the full design
capacity requirements of appurtenance wind area and weight as provided by the original
manufacturer specifications. It is the carrier’s responsibility to ensure compliance to the structural
limitations of the existing and/or proposed antenna mounts. TEP did not analyze antennas
supporting mounts as part of this structural analysis report.
6) Unless specified by the client or tower mapping, the location of the existing and proposed coax is
assumed by TEP and listed in Table 1.
7) The original tower geometry, foundation information, and geotechnical values were assumed
correct per the structural analysis performed by CBVR Telecom Design Group, dated June 26,
2019.
8) TEP assumes that the leg modifications by Kimley Horn and Associates and by Excell
Communications were designed to properly terminate at the flanges and adequately transfer the
load to the tower sections above and below.
This analysis may be affected if any assumptions are not valid or have been made in error. Tower
Engineering Professionals should be notified to determine the effect on the structural integrity of the
tower.
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 5
tnxTower report - version 8.1.1.0
4) ANALYSIS RESULTS
Table 3 - Section Capacity (Summary)
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) ΦPallow (K) %
Capacity Pass / Fail
T1 300 - 287.341 Leg ROHN 2 X-STR 2 -7.16 46.05 15.6 Pass
T2 287.341 - 280 Leg ROHN 2 X-STR 23 -35.95 69.78 51.5 Pass
T3 280 - 260 Leg ROHN 2 X-STR 50 -36.75 46.05 79.8 Pass
T4 260 - 240 Leg ROHN 2 X-STR 82 -33.30 46.05 72.3 Pass
T5 240 - 220 Leg ROHN 2 X-STR 115 -55.14 62.91 87.6 Pass
T6 220 - 200 Leg ROHN 2.5 EH w/ 3XS Half
Sleeve
Note 1 Note 1 Note 1 77.4 Pass
T7 200 - 180 Leg ROHN 2 X-STR w/ 3'' X-
STR Half-Sleeve
Note 1 Note 1 Note 1 64.3 Pass
T8 180 - 160 Leg ROHN 2 X-STR 286 -37.66 46.05 81.8 Pass
T9 160 - 140 Leg ROHN 2.5 STD 320 -55.70 75.22 74.0 Pass
T10 140 - 120 Leg ROHN 2.5 STD 377 -56.17 75.22 74.7 Pass
T11 120 - 100 Leg ROHN 2.5 STD 435 -53.97 61.33 88.0 Pass
T12 100 - 80 Leg ROHN 2.5 STD 467 -56.78 75.22 75.5 Pass
T13 80 - 60 Leg ROHN 2.5 STD 523 -58.93 75.22 78.4 Pass
T14 60 - 40 Leg ROHN 2.5 X STR 581 -74.09 85.78 86.4 Pass
T15 40 - 20 Leg ROHN 2.5 X STR 614 -74.36 85.78 86.7 Pass
T16 20 - 4.81771 Leg ROHN 2.5 X STR 646 -64.98 85.78 75.8 Pass
T17 4.81771 - 0 Leg ROHN 2.5 X STR 673 -57.10 112.31 50.8 Pass
T1 300 - 287.341 Diagonal ROHN 1.5 x 16GA 11 -2.96 6.16 48.1 Pass
T2 287.341 - 280 Diagonal L2x2x1/4 33 -6.79 20.62 32.9 Pass
T3 280 - 260 Diagonal ROHN 1.5 x 16GA 73 -3.95 6.16 64.2 Pass
T4 260 - 240 Diagonal ROHN 1.5 x 16GA 92 -3.18 6.16 51.7 Pass
T5 240 - 220 Diagonal ROHN 1.5 x 16GA 126 -3.30 6.16 53.6 Pass
T6 220 - 200 Diagonal ROHN 1.5 x 11GA 204 -5.61 12.04 46.6 Pass
T7 200 - 180 Diagonal ROHN 1.5 x 16GA 284 -3.57 6.16 57.9 Pass
T8 180 - 160 Diagonal ROHN 1.5 x 16GA 318 -3.12 6.16 50.7 Pass
T9 160 - 140 Diagonal ROHN 1.5 x 11GA 329 -3.73 11.83 31.6 Pass
T10 140 - 120 Diagonal ROHN 1.5 x 16GA 431 -3.64 6.24 58.3 Pass
T11 120 - 100 Diagonal ROHN 1.5 x 16GA 444 -3.44 6.24 55.2 Pass
T12 100 - 80 Diagonal ROHN 1.5 x 16GA 480 -3.65 6.24 58.6 Pass
T13 80 - 60 Diagonal ROHN 1.5 x 16GA 574 -3.38 6.24 54.1 Pass
T14 60 - 40 Diagonal ROHN 1.5 x 16GA 610 -4.70 6.24 75.3 Pass
T15 40 - 20 Diagonal ROHN 1.5 x 16GA 624 -4.19 6.24 67.2 Pass
T16 20 - 4.81771 Diagonal ROHN 1.5 x 16GA 657 -4.75 6.24 76.2 Pass
T17 4.81771 - 0 Horizontal L4x4x1/4 680 -1.05 72.39 13.8 Pass
T1 300 - 287.341 Top Girt ROHN 1.5 x 16GA 5 -0.34 7.33 4.6 Pass
T2 287.341 - 280 Top Girt L2x2x1/4 27 -1.60 25.14 6.4 Pass
T4 260 - 240 Top Girt ROHN 1.5 x 16GA 85 -0.87 7.33 11.8 Pass
T5 240 - 220 Top Girt ROHN 1.5 x 16GA 120 -1.00 7.33 13.6 Pass
T6 220 - 200 Top Girt ROHN 1.5 x 16GA 175 -1.40 7.48 18.8 Pass
T7 200 - 180 Top Girt ROHN 1.5 x 16GA 234 -1.03 7.33 14.1 Pass
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 6
tnxTower report - version 8.1.1.0
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) ΦPallow (K) %
Capacity Pass / Fail
T8 180 - 160 Top Girt ROHN 1.5 x 16GA 291 -1.26 7.33 17.2 Pass
T9 160 - 140 Top Girt ROHN 1.5 x 16GA 322 -1.02 7.40 13.8 Pass
T10 140 - 120 Top Girt ROHN 1.5 x 16GA 379 -1.02 7.40 13.8 Pass
T11 120 - 100 Top Girt ROHN 1.5 x 16GA 437 -0.93 7.40 12.6 Pass
T12 100 - 80 Top Girt ROHN 1.5 x 16GA 469 -1.04 7.40 14.1 Pass
T13 80 - 60 Top Girt ROHN 1.5 x 16GA 526 -1.05 7.40 14.2 Pass
T14 60 - 40 Top Girt ROHN 1.5 x 16GA 583 -1.72 7.40 23.2 Pass
T15 40 - 20 Top Girt ROHN 1.5 x 16GA 616 -1.29 7.40 17.4 Pass
T16 20 - 4.81771 Top Girt ROHN 1.5 x 16GA 650 -1.37 7.40 18.4 Pass
T17 4.81771 - 0 Top Girt L4x4x1/4 678 11.16 74.48 15.0 Pass
T2 287.341 - 280 Bottom Girt L2x2x1/4 29 2.60 28.81 9.0 Pass
T3 280 - 260 Bottom Girt ROHN 1.5 x 16GA 55 -0.87 7.33 11.9 Pass
T4 260 - 240 Bottom Girt ROHN 1.5 x 16GA 89 -1.32 7.33 18.0 Pass
T5 240 - 220 Bottom Girt ROHN 1.5 x 16GA 123 -1.00 7.33 13.6 Pass
T6 220 - 200 Bottom Girt L2 1/2x2 1/2x1/4 178 -1.40 32.15 4.4 Pass
T7 200 - 180 Bottom Girt ROHN 1.5 x 16GA 237 -1.03 7.33 14.1 Pass
T8 180 - 160 Bottom Girt ROHN 1.5 x 16GA 292 -1.31 7.33 17.8 Pass
T9 160 - 140 Bottom Girt ROHN 1.5 x 16GA 325 -1.02 7.40 13.8 Pass
T10 140 - 120 Bottom Girt ROHN 1.5 x 16GA 382 -1.02 7.40 13.8 Pass
T11 120 - 100 Bottom Girt ROHN 1.5 x 16GA 441 -1.22 7.40 16.5 Pass
T12 100 - 80 Bottom Girt ROHN 1.5 x 16GA 472 -1.04 7.40 14.1 Pass
T13 80 - 60 Bottom Girt ROHN 1.5 x 16GA 529 -1.05 7.40 14.2 Pass
T14 60 - 40 Bottom Girt ROHN 1.5 x 16GA 586 -1.28 7.40 17.3 Pass
T15 40 - 20 Bottom Girt ROHN 1.5 x 16GA 619 -1.29 7.40 17.4 Pass
T16 20 - 4.81771 Bottom Girt ROHN 1.5 x 16GA 654 1.68 10.43 16.2 Pass
T3 280 - 260 Guy A@279.385 3/4 690 35.33 36.73 96.2 Pass
T6 220 - 200 Guy A@209.75 9/16 700 16.16 22.05 73.3 Pass
T10 140 - 120 Guy A@139.385 9/16 708 18.67 22.05 84.7 Pass
T13 80 - 60 Guy A@79.3854 9/16 714 17.38 22.05 78.8 Pass
T3 280 - 260 Guy B@279.385 3/4 689 35.71 36.73 97.2 Pass
T6 220 - 200 Guy B@209.75 9/16 696 16.98 22.05 77.0 Pass
T10 140 - 120 Guy B@139.385 9/16 707 18.76 22.05 85.1 Pass
T13 80 - 60 Guy B@79.3854 9/16 713 17.41 22.05 79.0 Pass
T3 280 - 260 Guy C@279.385 3/4 688 35.59 36.73 96.9 Pass
T6 220 - 200 Guy C@209.75 9/16 691 16.93 22.05 76.8 Pass
T10 140 - 120 Guy C@139.385 9/16 703 18.33 22.05 83.1 Pass
T13 80 - 60 Guy C@79.3854 9/16 709 17.14 22.05 77.7 Pass
T3 280 - 260 Top Guy Pull-
Off@279.385
L2x2x1/4 54 13.32 25.71 51.8 Pass
T10 140 - 120 Top Guy Pull-
Off@139.385
4.5x3/8 706 7.60 57.41 13.2 Pass
T13 80 - 60 Top Guy Pull-
Off@79.3854
4.5x3/8 712 8.26 57.41 14.4 Pass
T6 220 - 200 Torque Arm
Top@209.75
C12x20.7 701 -4.88 181.27 55.2 Pass
Summary
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 7
tnxTower report - version 8.1.1.0
Section
No. Elevation (ft) Component Type Size Critical
Element P (K) ΦPallow (K) %
Capacity Pass / Fail
Leg (T11) 88.0 Pass
Diagonal
(T16)
76.2 Pass
Horizontal
(T17)
13.8 Pass
Top Girt
(T14)
23.2 Pass
Bottom
Girt (T4)
18.0 Pass
Guy A
(T3)
96.2 Pass
Guy B
(T3)
97.2 Pass
Guy C
(T3)
96.9 Pass
Top Guy
Pull-Off
(T3)
51.8 Pass
Torque
Arm Top
(T6)
55.2 Pass
Bolt
Checks
75.3 Pass
RATING = 97.2 Pass
Table 4 - Tower Component Stresses vs. Capacity
Notes Component Elevation (ft) % Capacity Pass / Fail
1,2 Mast Foundation Soil Interaction - 39.1 Pass
1,2 Mast Foundation Structural - 15.8 Pass
1,2 Inner Guy Anchor Foundation - 49.0 Pass
1,2 Inner Guy Anchor Shaft - 49.0 Pass
1,2 Outer Guy Anchor Foundation - 47.5 Pass
1,2 Outer Guy Anchor Shaft - 34.3 Pass
Structure Rating (max from all components) = 97.2%
Notes:
1) See additional documentation in “Appendix B - Additional Calculations” for calculations supporting the % capacity listed.
2) Rating per TIA-222-H, Section 15.5
4.1) Recommendations
1) If the load differs from that described in Table 1 of this report or the provisions of this analysis are
found to be invalid, another structural analysis should be performed.
2) The modifications depicted in “Appendix C – Structural Design Drawings” shall be installed and,
upon completion, inspected. The tower and its foundation have sufficient capacity to carry the
existing, proposed, and reserved loading once the proposed modifications are installed.
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 8
tnxTower report - version 8.1.1.0
APPENDIX A
TNX TOWER OUTPUT
TEP
Tower Engineering Professionals
326 Tryon Road
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Job: Adams Ranch (237546)
Project: TEP No. 152906.551427
Client: Verizon Wireless Drawn by: JRM App'd:
Code: TIA-222-H Date: 06/15/21 Scale: NTS
Path:
G:\Shared drives\152800 - 153499\152906\P-242151_L-551427_237546_ADAMS RANCH_Tower - Structural Design Drawings\TNX\Mod Run\237546 - Adams Ranch.eri
Dwg No. E-1
3
/
4
E
HS
L
C=
3
6
4
.
7
5
ft I
T
=
1
2
%R=240.00 ft
9/1
6
E
H
S
L
C
=
2
9
3.2
8 ft I
T
=
7
%R=209.00 ft
9
/
1
6
E
H
S
L
C
=
2
9
3
.
2
8
f
t
I
T
=
7%
9/16 E
H
S L
C
=248.47 ft IT=10
%
9/16 EHS LC=221.02 ft IT=10%
300.0 ft
287.3 ft
280.0 ft
260.0 ft
240.0 ft
220.0 ft
200.0 ft
209.8 ft209.8 ft209.8 ft209.8 ft209.8 ft209.8 ft
180.0 ft
160.0 ft
140.0 ft
120.0 ft
100.0 ft
80.0 ft
60.0 ft
40.0 ft
20.0 ft
4.8 ft
0.0 ft
146 K (Axial)
6 kip-ft (Torque)
3 K 55 K
38 K
67 K 24 K
26 K
3
5
K
ALL REACTIONS ARE FACTORED
SectionT1T2T3T4T5T6T7T8T9T10T11T12T13T14T15T16T17 LegsROHN 2 X-STRABROHN 2 X-STRROHN 2.5 STDROHN 2.5 X STR Leg GradeA572-50 DiagonalsCDROHN 1.5 x 16GAEROHN 1.5 x 16GAEROHN 1.5 x 16GAF Diagonal GradeA53-B-42GA53-B-42A500-42A53-B-42A500-42A53-B-42F Top GirtsCDN.A.ROHN 1.5 x 16GAH Bottom GirtsN.A.DROHN 1.5 x 16GAIROHN 1.5 x 16GAF HorizontalsN.A.H Top Guy Pull-OffsN.A.L2x2x1/4N.A.4.5x3/8N.A.4.5x3/8N.A. Face Width (ft)3.41667 # Panels @ (ft)5 @ 2.40886J110 @ 2.40885K Weight (K)0.30.40.50.40.51.70.80.40.80.60.50.60.60.60.60.50.310.2PLAN
R=242.00 ft (3)R=240.00 ft (3)
R=240.00 ft (3)
R=208.00 ft (2)R=209.00 ft (2)
R=206.00 ft (2)
R=208.00 ft (2)R=209.00 ft (2)
R=206.00 ft (2)
R=208.00 ft (2)R=209.00 ft (2)
R=206.00 ft (2)
SYMBOL LIST
MARK MARKSIZE SIZE
A ROHN 2.5 EH w/ 3XS Half Sleeve
B ROHN 2 X-STR w/ 3" X-STR Half-Sleeve
C ROHN 1.5 x 16GA
D L2x2x1/4
E ROHN 1.5 x 11GA
F N.A.
G A572-50
H L4x4x1/4
I L2 1/2x2 1/2x1/4
J 3 @ 2.40884
K 4 @ 1.20443
MATERIAL STRENGTH
GRADE GRADEFy FyFu Fu
A572-50 50 ksi 65 ksi
A53-B-42 42 ksi 63 ksi
A500-42 42 ksi 58 ksi
TOWER DESIGN NOTES
1. Tower designed for Exposure C to the TIA-222-H Standard.
2. Tower designed for a 153 mph basic wind in accordance with the TIA-222-H Standard.
3. Deflections are based upon a 60 mph wind.
4. Tower Risk Category II.
5. Topographic Category 1 with Crest Height of 0.00 ft
6. TOWER RATING: 97.2%
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
1 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower Input Data
The main tower is a 3x guyed tower with an overall height of 300.00 ft above the ground line.
The base of the tower is set at an elevation of 0.00 ft above the ground line.
The face width of the tower is 3.42 ft at the top and tapered at the base.
This tower is designed using the TIA-222-H standard.
The following design criteria apply:
Tower base elevation above sea level: 20.00 ft.
Basic wind speed of 153 mph.
Risk Category II.
Exposure Category C.
Simplified Topographic Factor Procedure for wind speed-up calculations is used.
Topographic Category: 1.
Crest Height: 0.00 ft.
Deflections calculated using a wind speed of 60 mph.
Pressures are calculated at each section.
Stress ratio used in tower member design is 1.
Safety factor used in guy design is 1.
Tower analysis based on target reliabilities in accordance with Annex S.
Load Modification Factors used: Kes(Fw) = 0.95.
Maximum demand-capacity ratio is: 1.05.
Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules
Consider Moments - Horizontals Assume Legs Pinned √ Calculate Redundant Bracing Forces
Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA
Use Moment Magnification √ Use Clear Spans For Wind Area SR Leg Bolts Resist Compression
√ Use Code Stress Ratios √ Use Clear Spans For KL/r All Leg Panels Have Same Allowable
√ Use Code Safety Factors - Guys √ Retension Guys To Initial Tension Offset Girt At Foundation
Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque
Always Use Max Kz √ Use Azimuth Dish Coefficients √ Include Angle Block Shear Check
Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-H Bracing Resist. Exemption
Include Bolts In Member Capacity √ Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption
Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles
√ Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Include Shear-Torsion Interaction
Use Diamond Inner Bracing (4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow
SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets
SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments
Pole With Shroud Or No Appurtenances
Outside and Inside Corner Radii Are
Known
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
2 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Leg B
Guy B
Leg C
G u y C Leg A Guy A Face A F
a
c
e
B
Face C
Corner & Starmount Guyed Tower
Wind 0
Wind 90
Wind 180
Z
X
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
3 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Leg B Guy
B
Leg C
Guy C
Leg A Guy A Face A F
a
c
e
B
Face C
Face Guyed
Wind 0
Wind 90
Wind 180
Z
X
Tower Section Geometry
Tower
Section
Tower
Elevation
ft
Assembly
Database
Description Section
Width
ft
Number
of
Sections
Section
Length
ft
T1 300.00-287.34 3.42 1 12.66
T2 287.34-280.00 3.42 1 7.34
T3 280.00-260.00 3.42 1 20.00
T4 260.00-240.00 3.42 1 20.00
T5 240.00-220.00 3.42 1 20.00
T6 220.00-200.00 3.42 1 20.00
T7 200.00-180.00 3.42 1 20.00
T8 180.00-160.00 3.42 1 20.00
T9 160.00-140.00 3.42 1 20.00
T10 140.00-120.00 3.42 1 20.00
T11 120.00-100.00 3.42 1 20.00
T12 100.00-80.00 3.42 1 20.00
T13 80.00-60.00 3.42 1 20.00
T14 60.00-40.00 3.42 1 20.00
T15 40.00-20.00 3.42 1 20.00
T16 20.00-4.82 3.42 1 15.18
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
4 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Section
Tower
Elevation
ft
Assembly
Database
Description Section
Width
ft
Number
of
Sections
Section
Length
ft
T17 4.82-0.00 3.42 1 4.82
Tower Section Geometry (cont’d)
Tower
Section
Tower
Elevation
ft
Diagonal
Spacing
ft
Bracing
Type
Has
K Brace
End
Panels
Has
Horizontals
Top Girt
Offset
in
Bottom Girt
Offset
in
T1 300.00-287.34 2.41 K Brace Right No No 7.3750 0.0000
T2 287.34-280.00 2.41 CX Brace No No 0.0000 1.3750
T3 280.00-260.00 2.41 K Brace Left No No 7.3750 1.3750
T4 260.00-240.00 2.41 K Brace Left No No 7.3750 1.3750
T5 240.00-220.00 2.41 CX Brace No No 7.3750 1.3750
T6 220.00-200.00 2.41 CX Brace No No 7.3750 1.3750
T7 200.00-180.00 2.41 CX Brace No No 7.3750 1.3750
T8 180.00-160.00 2.41 K Brace Left No No 7.3750 1.3750
T9 160.00-140.00 2.41 CX Brace No No 7.3750 1.3750
T10 140.00-120.00 2.41 CX Brace No No 7.3750 1.3750
T11 120.00-100.00 2.41 K Brace Left No No 7.3750 1.3750
T12 100.00-80.00 2.41 CX Brace No No 7.3750 1.3750
T13 80.00-60.00 2.41 CX Brace No No 7.3750 1.3750
T14 60.00-40.00 2.41 K Brace Left No No 7.3750 1.3750
T15 40.00-20.00 2.41 K Brace Left No No 7.3750 1.3750
T16 20.00-4.82 2.41 K Brace Left No No 7.3750 1.3750
T17 4.82-0.00 1.20 X Brace No Yes 0.0000 0.0000
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Leg
Type
Leg
Size
Leg
Grade
Diagonal
Type
Diagonal
Size
Diagonal
Grade
T1 300.00-287.34 Pipe ROHN 2 X-STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T2 287.34-280.00 Pipe ROHN 2 X-STR A572-50
(50 ksi)
Equal Angle L2x2x1/4 A572-50
(50 ksi)
T3 280.00-260.00 Pipe ROHN 2 X-STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T4 260.00-240.00 Pipe ROHN 2 X-STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T5 240.00-220.00 Pipe ROHN 2 X-STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T6 220.00-200.00 Arbitrary Shape ROHN 2.5 EH w/ 3XS Half
Sleeve
A572-50
(50 ksi)
Pipe ROHN 1.5 x 11GA A500-42
(42 ksi)
T7 200.00-180.00 Arbitrary Shape ROHN 2 X-STR w/ 3'' X-STR
Half-Sleeve
A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T8 180.00-160.00 Pipe ROHN 2 X-STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T9 160.00-140.00 Pipe ROHN 2.5 STD A572-50
(50 ksi)
Pipe ROHN 1.5 x 11GA A500-42
(42 ksi)
T10
140.00-120.00
Pipe ROHN 2.5 STD A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T11 Pipe ROHN 2.5 STD A572-50 Pipe ROHN 1.5 x 16GA A53-B-42
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
5 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Elevation
ft
Leg
Type
Leg
Size
Leg
Grade
Diagonal
Type
Diagonal
Size
Diagonal
Grade
120.00-100.00 (50 ksi) (42 ksi)
T12 100.00-80.00 Pipe ROHN 2.5 STD A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T13 80.00-60.00 Pipe ROHN 2.5 STD A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T14 60.00-40.00 Pipe ROHN 2.5 X STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T15 40.00-20.00 Pipe ROHN 2.5 X STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T16 20.00-4.82 Pipe ROHN 2.5 X STR A572-50
(50 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T17 4.82-0.00 Pipe ROHN 2.5 X STR A572-50
(50 ksi)
Equal Angle A36
(36 ksi)
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Top Girt
Type
Top Girt
Size
Top Girt
Grade
Bottom Girt
Type
Bottom Girt
Size
Bottom Girt
Grade
T1 300.00-287.34 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Equal Angle A36
(36 ksi)
T2 287.34-280.00 Equal Angle L2x2x1/4 A572-50
(50 ksi)
Equal Angle L2x2x1/4 A572-50
(50 ksi)
T3 280.00-260.00 Equal Angle L2x2x1/4 A36
(36 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T4 260.00-240.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T5 240.00-220.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T6 220.00-200.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Equal Angle L2 1/2x2 1/2x1/4 A36
(36 ksi)
T7 200.00-180.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T8 180.00-160.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T9 160.00-140.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T10
140.00-120.00
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T11
120.00-100.00
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T12 100.00-80.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T13 80.00-60.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T14 60.00-40.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T15 40.00-20.00 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T16 20.00-4.82 Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
Pipe ROHN 1.5 x 16GA A53-B-42
(42 ksi)
T17 4.82-0.00 Equal Angle L4x4x1/4 A572-50
(50 ksi)
Equal Angle A572-50
(50 ksi)
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
6 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower Section Geometry (cont’d)
Tower
Elevation
ft
No.
of
Mid
Girts
Mid Girt
Type
Mid Girt
Size
Mid Girt
Grade
Horizontal
Type
Horizontal
Size
Horizontal
Grade
T17 4.82-0.00 None Flat Bar A36
(36 ksi)
Equal Angle L4x4x1/4 A572-50
(50 ksi)
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Gusset
Area
(per face)
ft2
Gusset
Thickness
in
Gusset Grade Adjust. Factor
Af
Adjust.
Factor
Ar
Weight Mult.
Double Angle
Stitch Bolt
Spacing
Diagonals
in
Double Angle
Stitch Bolt
Spacing
Horizontals
in
Double Angle
Stitch Bolt
Spacing
Redundants
in
T1
300.00-287.34
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T2
287.34-280.00
0.00 0.1543 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T3
280.00-260.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T4
260.00-240.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T5
240.00-220.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T6
220.00-200.00
0.00 0.1757 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T7
200.00-180.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T8
180.00-160.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T9
160.00-140.00
0.00 0.1757 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T10
140.00-120.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T11
120.00-100.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T12
100.00-80.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T13
80.00-60.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T14
60.00-40.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T15
40.00-20.00
0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T16 20.00-4.82 0.00 0.3750 A36
(36 ksi)
1 1.03 1.05 Third-Pt Third-Pt Third-Pt
T17 4.82-0.00 0.00 0.0000 A36
(36 ksi)
1 1 1 Third-Pt Third-Pt Third-Pt
Tower Section Geometry (cont’d)
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
7 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
K Factors1
Tower
Elevation
ft
Calc
K
Single
Angles
Calc
K
Solid
Rounds
Legs X
Brace
Diags
X
Y
K
Brace
Diags
X
Y
Single
Diags
X
Y
Girts
X
Y
Horiz.
X
Y
Sec.
Horiz.
X
Y
Inner
Brace
X
Y
T1
300.00-287.34
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T2
287.34-280.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T3
280.00-260.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T4
260.00-240.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T5
240.00-220.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T6
220.00-200.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T7
200.00-180.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T8
180.00-160.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T9
160.00-140.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T10
140.00-120.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T11
120.00-100.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T12
100.00-80.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T13
80.00-60.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T14
60.00-40.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T15
40.00-20.00
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T16
20.00-4.82
Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
T17 4.82-0.00 Yes Yes 1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
1Note: K factors are applied to member segment lengths. K-braces without inner supporting members will have the K factor in the out-of-plane direction applied to
the overall length.
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
T1
300.00-287.34
0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 1 0.0000 0.75
T2
287.34-280.00
0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 1 0.0000 0.75
T3
280.00-260.00
0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T4
260.00-240.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
8 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Elevation
ft
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
T5
240.00-220.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T6
220.00-200.00
0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 1 0.0000 0.75
T7
200.00-180.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T8
180.00-160.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T9
160.00-140.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T10
140.00-120.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T11
120.00-100.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T12
100.00-80.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T13
80.00-60.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T14
60.00-40.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T15
40.00-20.00
0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T16 20.00-4.82 0.0000 1 0.0000 1 0.0000 1 0.0000 1 0.0000 0.75 0.0000 1 0.0000 0.75
T17 4.82-0.00 0.0000 1 0.0000 1 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
Tower
Elevation
ft
Redundant
Horizontal
Redundant
Diagonal
Redundant
Sub-Diagonal
Redundant
Sub-Horizontal
Redundant Vertical Redundant Hip Redundant Hip
Diagonal
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
T1
300.00-287.34
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T2
287.34-280.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T3
280.00-260.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T4
260.00-240.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T5
240.00-220.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T6
220.00-200.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T7
200.00-180.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T8
180.00-160.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T9
160.00-140.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T10
140.00-120.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T11
120.00-100.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
9 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Elevation
ft
Redundant
Horizontal
Redundant
Diagonal
Redundant
Sub-Diagonal
Redundant
Sub-Horizontal
Redundant Vertical Redundant Hip Redundant Hip
Diagonal
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
Net
Width
Deduct
in
U
T12
100.00-80.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T13
80.00-60.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T14
60.00-40.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T15
40.00-20.00
0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T16 20.00-4.82 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T17 4.82-0.00 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
Tower Section Geometry (cont’d)
Tower
Elevation
ft
Leg
Connection
Type
Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No. Bolt Size
in
No.
T1
300.00-287.34
Flange 0.7500
A325X
0 0.5000
A325X
1 0.5000
A325X
1 0.0000
A325X
0 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T2
287.34-280.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T3
280.00-260.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.6250
A325X
2 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T4
260.00-240.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T5
240.00-220.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T6
220.00-200.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T7
200.00-180.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T8
180.00-160.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T9
160.00-140.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T10
140.00-120.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T11
120.00-100.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T12
100.00-80.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T13
80.00-60.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T14
60.00-40.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T15
40.00-20.00
Flange 0.7500
A325X
4 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T16 20.00-4.82 Flange 0.7500
A325X
0 0.5000
A325X
1 0.5000
A325X
1 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
T17 4.82-0.00 Flange 0.7500
A325X
0 0.0000
A325X
0 0.0000
A325X
0 0.5000
A325X
1 0.6250
A325N
0 0.0000
A325N
0 0.6250
A325N
0
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
10 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Guy Data
Guy
Elevation
ft
Guy
Grade
Guy
Size
Initial
Tension
K
%
Guy
Modulus
ksi
Guy
Weight
plf
Lu
ft
Anchor
Radius
ft
Anchor
Azimuth
Adj.
°
Anchor
Elevation
ft
End
Fitting
Efficiency
%
279.385 EHS A
B
C
3/4
3/4
3/4
7.00
7.00
7.00
12%
12%
12%
24000
24000
24000
1.155
1.155
1.155
364.45
364.45
365.76
240.00
240.00
242.00
0.0000
0.0000
0.0000
3.00
3.00
3.00
100%
100%
100%
209.75 EHS A
B
C
9/16
9/16
9/16
2.45
2.45
2.45
7%
7%
7%
23000
23000
23000
0.671
0.671
0.671
291.04
293.15
292.45
206.00
209.00
208.00
0.0000
0.0000
0.0000
2.00
2.00
2.00
100%
100%
100%
139.385 EHS A
B
C
9/16
9/16
9/16
3.50
3.50
3.50
10%
10%
10%
23000
23000
23000
0.671
0.671
0.671
245.79
248.28
247.45
206.00
209.00
208.00
0.0000
0.0000
0.0000
2.00
2.00
2.00
100%
100%
100%
79.3854 EHS A
B
C
9/16
9/16
9/16
3.50
3.50
3.50
10%
10%
10%
23000
23000
23000
0.671
0.671
0.671
218.05
220.86
219.92
206.00
209.00
208.00
0.0000
0.0000
0.0000
2.00
2.00
2.00
100%
100%
100%
Guy Data(cont’d)
Guy
Elevation
ft
Mount
Type
Torque-Arm
Spread
ft
Torque-Arm
Leg Angle
°
Torque-Arm
Style
Torque-Arm
Grade
Torque-Arm
Type
Torque-Arm Size
279.385 Corner
209.75 Torque Arm 7.00 0.0000 Channel A36
(36 ksi)
Channel C12x20.7
139.385 Corner
79.3854 Corner
Guy Data (cont’d)
Guy
Elevation
ft
Diagonal
Grade
Diagonal
Type
Upper Diagonal
Size
Lower Diagonal
Size
Is
Strap.
Pull-Off
Grade
Pull-Off Type Pull-Off Size
279.39 A572-50
(50 ksi)
Solid Round No A36
(36 ksi)
Equal Angle L2x2x1/4
209.75 A572-50
(50 ksi)
Solid Round A36
(36 ksi)
Solid Round
139.39 A572-50
(50 ksi)
Solid Round Yes A36
(36 ksi)
Flat Bar 4.5x3/8
79.39 A572-50
(50 ksi)
Solid Round Yes A36
(36 ksi)
Flat Bar 4.5x3/8
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
11 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Guy Data (cont’d)
Guy
Elevation
ft
Cable
Weight
A
K
Cable
Weight
B
K
Cable
Weight
C
K
Cable
Weight
D
K
Tower
Intercept
A
ft
Tower
Intercept
B
ft
Tower
Intercept
C
ft
Tower
Intercept
D
ft
279.385 0.42 0.42 0.42 10.73
5.7 sec/pulse
10.73
5.7 sec/pulse
10.81
5.7 sec/pulse
209.75 0.20 0.20 0.20 11.29
5.8 sec/pulse
11.45
5.8 sec/pulse
11.40
5.8 sec/pulse
139.385 0.16 0.17 0.17 5.72
4.1 sec/pulse
5.84
4.2 sec/pulse
5.80
4.2 sec/pulse
79.3854 0.15 0.15 0.15 4.53
3.7 sec/pulse
4.65
3.7 sec/pulse
4.61
3.7 sec/pulse
Guy Data (cont’d)
Torque Arm Pull Off Diagonal
Guy
Elevation
ft
Calc
K
Single
Angles
Calc
K
Solid
Rounds
Kx Ky Kx Ky Kx Ky
279.385 Yes No 1 1 1 1
209.75 Yes No 1 1 1 1 1 1
139.385 Yes No 1 1 1 1
79.3854 Yes No 1 1 1 1
Guy Data (cont’d)
Torque-Arm Pull Off Diagonal
Guy
Elevation
ft
Bolt Size
in
Number Net Width
Deduct
in
U
Bolt Size
in
Number Net Width
Deduct
in
U
Bolt Size
in
Number Net Width
Deduct
in
U
279.385 0.0000
A325N
0 0.0000 0.75 0.6250
A325X
2 0.0000 0.75 0.6250
A325N
0 0.0000 0.75
209.75 0.6250
A325X
2 0.0000 0.75 0.0000
A325X
0 0.0000 0.75 0.6250
A325N
0 0.0000 0.75
139.385 0.0000
A325N
0 0.0000 0.75 0.7500
A325X
2 0.0000 1 0.6250
A325N
0 0.0000 0.75
79.3854 0.0000
A325N
0 0.0000 0.75 0.7500
A325X
2 0.0000 1 0.6250
A325N
0 0.0000 0.75
Guy Pressures
Guy
Elevation
ft
Guy
Location
z
ft
qz
psf
qz
Ice
psf
Ice
Thickness
in
279.385 A
B
C
141.19
141.19
141.19
66
66
66
209.75 A
B
105.88
105.88
62
62
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
12 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Guy
Elevation
ft
Guy
Location
z
ft
qz
psf
qz
Ice
psf
Ice
Thickness
in
C 105.88 62
139.385 A
B
C
70.69
70.69
70.69
57
57
57
79.3854 A
B
C
40.69
40.69
40.69
51
51
51
Guy-Tensioning Information
Temperature At Time Of Tensioning
0 F
20 F
40 F
60 F
80 F
100 F
120 F
Guy
Elevation
ft
H
ft
V
ft
Initial
Tension
K
Intercept
ft
Initial
Tension
K
Intercept
ft
Initial
Tension
K
Intercept
ft
Initial
Tension
K
Intercept
ft
Initial
Tension
K
Intercept
ft
Initial
Tension
K
Intercept
ft
Initial
Tension
K
Intercept
ft
279.385 A
B
C
238.03
238.03
240.03
276.39
276.39
276.39
8.204
8.204
8.214
9.18
9.18
9.23
7.795
7.795
7.802
9.65
9.65
9.71
7.392
7.392
7.395
10.17
10.17
10.24
6.996
6.996
6.996
10.73
10.73
10.81
6.608
6.608
6.605
11.35
11.35
11.43
6.229
6.229
6.223
12.02
12.02
12.12
5.861
5.861
5.853
12.76
12.76
12.87
209.75 A
B
C
204.01
207.01
206.01
207.75
207.75
207.75
3.104
3.109
3.108
8.96
9.07
9.03
2.874
2.877
2.876
9.66
9.79
9.74
2.655
2.657
2.656
10.43
10.58
10.53
2.450
2.450
2.450
11.29
11.45
11.40
2.259
2.258
2.258
12.22
12.40
12.34
2.084
2.082
2.083
13.21
13.41
13.35
1.925
1.923
1.924
14.27
14.49
14.42
139.385 A
B
C
204.03
207.03
206.03
137.39
137.39
137.39
4.586
4.593
4.590
4.38
4.46
4.43
4.215
4.219
4.218
4.76
4.85
4.82
3.852
3.854
3.854
5.20
5.31
5.27
3.500
3.500
3.500
5.72
5.84
5.80
3.162
3.160
3.161
6.33
6.46
6.41
2.841
2.839
2.840
7.03
7.18
7.13
2.543
2.541
2.542
7.84
8.01
7.95
79.3854 A
B
C
204.03
207.03
206.03
77.39
77.39
77.39
4.889
4.891
4.890
3.25
3.33
3.30
4.413
4.414
4.414
3.60
3.69
3.66
3.949
3.949
3.949
4.02
4.12
4.09
3.500
3.500
3.500
4.53
4.65
4.61
3.074
3.074
3.074
5.15
5.28
5.24
2.679
2.681
2.680
5.90
6.05
6.00
2.326
2.329
2.328
6.79
6.96
6.90
Feed Line/Linear Appurtenances - Entered As Round Or Flat
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Component
Type
Placement
ft
Face
Offset
in
Lateral
Offset
(Frac FW)
# #
Per
Row
Clear
Spacing
in
Width or
Diameter
in
Perimeter
in
Weight
plf
Safety Line
3/8
A No No Ar (CaAa) 300.00 -
5.00
0.0000 0.5 1 1 0.3750 0.3750 0.22
Step Pegs
(5/8'' SR) 7-in.
w/30'' step
A No No Ar (CaAa) 300.00 -
5.00
0.0000 0.5 1 1 0.3500 0.3500 0.49
***
L2x2x1/8 (40''
W 58'' Step)
A No No Af (CaAa) 300.00 -
5.00
0.0000 0 1 1 1.3790 1.3790 1.15
LDF7-50A(1-
5/8)
A No No Ar (CaAa) 285.00 -
11.00
0.0000 0 14 7 0.5000 1.9800 0.82
3/8'' Cable
(Lights)
A No No Ar (CaAa) 300.00 -
11.00
0.0000 0.48 1 1 0.3750 0.3750 0.22
9/16'' Feedline A No No Ar (CaAa) 59.00 -
11.00
0.0000 0.49 1 1 0.5000 0.6875 0.33
EW63(ELLIP
TICAL)
A No No Ar (CaAa) 127.00 -
11.00
0.0000 0.3 1 1 0.5000 2.0100 0.51
MLCH 12/24
LOW
INDUCTION(
2)
A No No Ar (CaAa) 285.00 -
11.00
0.0000 -0.3 2 2 0.5000 2.0160 3.04
***
L2x2x1/8 (40''
W 58'' Step)
B No No Af (CaAa) 300.00 -
5.00
0.0000 0 1 1 1.3790 1.3790 1.15
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
13 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Description Face
or
Leg
Allow
Shield
Exclude
From
Torque
Calculation
Component
Type
Placement
ft
Face
Offset
in
Lateral
Offset
(Frac FW)
# #
Per
Row
Clear
Spacing
in
Width or
Diameter
in
Perimeter
in
Weight
plf
LDF7-50A(1-
5/8)
B No No Ar (CaAa) 298.50 -
11.00
0.0000 -0.4 1 1 0.5000 1.9800 0.82
EW63(ELLIP
TICAL)
B No No Ar (CaAa) 115.00 -
11.00
0.0000 0.4 1 1 0.5000 2.0100 0.51
***
D-X wind area A No No Af (CaAa) 100.00 -
60.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area B No No Af (CaAa) 100.00 -
60.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area C No No Af (CaAa) 100.00 -
60.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area A No No Af (CaAa) 160.00 -
120.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area B No No Af (CaAa) 160.00 -
120.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area C No No Af (CaAa) 160.00 -
120.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area A No No Af (CaAa) 287.30 -
280.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area B No No Af (CaAa) 287.30 -
280.00
0.0000 0 1 1 0.0000 1.3000 3.20
D-X wind area C No No Af (CaAa) 287.30 -
280.00
0.0000 0 1 1 0.0000 1.3000 3.20
Feed Line/Linear Appurtenances Section Areas
Tower
Section
Tower
Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
T1 300.00-287.34 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
4.302
5.119
0.000
0.000
0.000
0.000
0.03
0.02
0.00
T2 287.34-280.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
19.952
4.722
1.582
0.000
0.000
0.000
0.13
0.04
0.02
T3 280.00-260.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
70.301
8.557
0.000
0.000
0.000
0.000
0.39
0.04
0.00
T4 260.00-240.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
70.301
8.557
0.000
0.000
0.000
0.000
0.39
0.04
0.00
T5 240.00-220.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
70.301
8.557
0.000
0.000
0.000
0.000
0.39
0.04
0.00
T6 220.00-200.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
70.301
8.557
0.000
0.000
0.000
0.000
0.39
0.04
0.00
T7 200.00-180.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
70.301
8.557
0.000
0.000
0.000
0.000
0.39
0.04
0.00
T8 180.00-160.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
70.301
8.557
0.000
0.000
0.000
0.000
0.39
0.04
0.00
T9 160.00-140.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
74.634
12.890
4.333
0.000
0.000
0.000
0.46
0.10
0.06
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
14 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Section
Tower
Elevation
ft
Face AR
ft2
AF
ft2
CAAA
In Face
ft2
CAAA
Out Face
ft2
Weight
K
T10 140.00-120.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
76.041
12.890
4.333
0.000
0.000
0.000
0.46
0.10
0.06
T11 120.00-100.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
74.321
11.572
0.000
0.000
0.000
0.000
0.40
0.05
0.00
T12 100.00-80.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
78.654
16.910
4.333
0.000
0.000
0.000
0.47
0.11
0.06
T13 80.00-60.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
78.654
16.910
4.333
0.000
0.000
0.000
0.47
0.11
0.06
T14 60.00-40.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
75.627
12.577
0.000
0.000
0.000
0.000
0.41
0.05
0.00
T15 40.00-20.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
75.696
12.577
0.000
0.000
0.000
0.000
0.41
0.05
0.00
T16 20.00-4.82 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
35.877
7.039
0.000
0.000
0.000
0.000
0.20
0.03
0.00
T17 4.82-0.00 A
B
C
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.00
0.00
0.00
Feed Line Center of Pressure
Section Elevation
ft
CPX
in
CPZ
in
CPX
Ice
in
CPZ
Ice
in
T1 300.00-287.34 0.2101 -3.6936 0.2101 -3.6936
T2 287.34-280.00 -2.0270 -2.8183 -2.0270 -2.8183
T3 280.00-260.00 -4.5760 -4.2951 -4.5760 -4.2951
T4 260.00-240.00 -4.6571 -4.3393 -4.6571 -4.3393
T5 240.00-220.00 -4.1877 -3.9787 -4.1877 -3.9787
T6 220.00-200.00 -3.8677 -3.7383 -3.7914 -3.6763
T7 200.00-180.00 -3.9099 -3.7585 -3.8348 -3.6981
T8 180.00-160.00 -4.6571 -4.3393 -4.6571 -4.3393
T9 160.00-140.00 -3.6439 -3.5749 -3.6265 -3.5605
T10 140.00-120.00 -3.5033 -3.6302 -3.4910 -3.6193
T11 120.00-100.00 -3.6138 -4.3534 -3.5975 -4.3371
T12 100.00-80.00 -2.7636 -3.6410 -2.7583 -3.6350
T13 80.00-60.00 -2.6498 -3.5327 -2.6480 -3.5306
T14 60.00-40.00 -3.2764 -4.4634 -3.2764 -4.4634
T15 40.00-20.00 -3.2742 -4.4763 -3.2742 -4.4763
T16 20.00-4.82 -2.3895 -3.8094 -2.3895 -3.8094
T17 4.82-0.00 0.0000 0.0000 0.0000 0.0000
Shielding Factor Ka
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
15 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
T1 1 Safety Line 3/8 287.34 -
300.00
0.6000 0.6000
T1 2 Step Pegs (5/8" SR) 7-in.
w/30" step
287.34 -
300.00
0.6000 0.6000
T1 4 L2x2x1/8 (40" W 58" Step) 287.34 -
300.00
0.6000 0.6000
T1 6 3/8" Cable (Lights) 287.34 -
300.00
0.6000 0.6000
T1 11 L2x2x1/8 (40" W 58" Step) 287.34 -
300.00
0.6000 0.6000
T1 12 LDF7-50A(1-5/8) 287.34 -
298.50
0.6000 0.6000
T2 1 Safety Line 3/8 280.00 -
287.34
0.6000 0.6000
T2 2 Step Pegs (5/8" SR) 7-in.
w/30" step
280.00 -
287.34
0.6000 0.6000
T2 4 L2x2x1/8 (40" W 58" Step) 280.00 -
287.34
0.6000 0.6000
T2 5 LDF7-50A(1-5/8) 280.00 -
285.00
0.6000 0.6000
T2 6 3/8" Cable (Lights) 280.00 -
287.34
0.6000 0.6000
T2 9 MLCH 12/24 LOW
INDUCTION(2)
280.00 -
285.00
0.6000 0.6000
T2 11 L2x2x1/8 (40" W 58" Step) 280.00 -
287.34
0.6000 0.6000
T2 12 LDF7-50A(1-5/8) 280.00 -
287.34
0.6000 0.6000
T2 21 D-X wind area 280.00 -
287.30
0.6000 0.6000
T2 22 D-X wind area 280.00 -
287.30
0.6000 0.6000
T2 23 D-X wind area 280.00 -
287.30
0.6000 0.6000
T3 1 Safety Line 3/8 260.00 -
280.00
0.6000 0.6000
T3 2 Step Pegs (5/8" SR) 7-in.
w/30" step
260.00 -
280.00
0.6000 0.6000
T3 4 L2x2x1/8 (40" W 58" Step) 260.00 -
280.00
0.6000 0.6000
T3 5 LDF7-50A(1-5/8) 260.00 -
280.00
0.6000 0.6000
T3 6 3/8" Cable (Lights) 260.00 -
280.00
0.6000 0.6000
T3 9 MLCH 12/24 LOW
INDUCTION(2)
260.00 -
280.00
0.6000 0.6000
T3 11 L2x2x1/8 (40" W 58" Step) 260.00 -
280.00
0.6000 0.6000
T3 12 LDF7-50A(1-5/8) 260.00 -
280.00
0.6000 0.6000
T4 1 Safety Line 3/8 240.00 -
260.00
0.6000 0.6000
T4 2 Step Pegs (5/8" SR) 7-in.
w/30" step
240.00 -
260.00
0.6000 0.6000
T4 4 L2x2x1/8 (40" W 58" Step) 240.00 -
260.00
0.6000 0.6000
T4 5 LDF7-50A(1-5/8) 240.00 -
260.00
0.6000 0.6000
T4 6 3/8" Cable (Lights) 240.00 -
260.00
0.6000 0.6000
T4 9 MLCH 12/24 LOW
INDUCTION(2)
240.00 -
260.00
0.6000 0.6000
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
16 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
T4 11 L2x2x1/8 (40" W 58" Step) 240.00 -
260.00
0.6000 0.6000
T4 12 LDF7-50A(1-5/8) 240.00 -
260.00
0.6000 0.6000
T5 1 Safety Line 3/8 220.00 -
240.00
0.6000 0.6000
T5 2 Step Pegs (5/8" SR) 7-in.
w/30" step
220.00 -
240.00
0.6000 0.6000
T5 4 L2x2x1/8 (40" W 58" Step) 220.00 -
240.00
0.6000 0.6000
T5 5 LDF7-50A(1-5/8) 220.00 -
240.00
0.6000 0.6000
T5 6 3/8" Cable (Lights) 220.00 -
240.00
0.6000 0.6000
T5 9 MLCH 12/24 LOW
INDUCTION(2)
220.00 -
240.00
0.6000 0.6000
T5 11 L2x2x1/8 (40" W 58" Step) 220.00 -
240.00
0.6000 0.6000
T5 12 LDF7-50A(1-5/8) 220.00 -
240.00
0.6000 0.6000
T6 1 Safety Line 3/8 200.00 -
220.00
0.6000 0.6000
T6 2 Step Pegs (5/8" SR) 7-in.
w/30" step
200.00 -
220.00
0.6000 0.6000
T6 4 L2x2x1/8 (40" W 58" Step) 200.00 -
220.00
0.6000 0.6000
T6 5 LDF7-50A(1-5/8) 200.00 -
220.00
0.6000 0.6000
T6 6 3/8" Cable (Lights) 200.00 -
220.00
0.6000 0.6000
T6 9 MLCH 12/24 LOW
INDUCTION(2)
200.00 -
220.00
0.6000 0.6000
T6 11 L2x2x1/8 (40" W 58" Step) 200.00 -
220.00
0.6000 0.6000
T6 12 LDF7-50A(1-5/8) 200.00 -
220.00
0.6000 0.6000
T7 1 Safety Line 3/8 180.00 -
200.00
0.6000 0.6000
T7 2 Step Pegs (5/8" SR) 7-in.
w/30" step
180.00 -
200.00
0.6000 0.6000
T7 4 L2x2x1/8 (40" W 58" Step) 180.00 -
200.00
0.6000 0.6000
T7 5 LDF7-50A(1-5/8) 180.00 -
200.00
0.6000 0.6000
T7 6 3/8" Cable (Lights) 180.00 -
200.00
0.6000 0.6000
T7 9 MLCH 12/24 LOW
INDUCTION(2)
180.00 -
200.00
0.6000 0.6000
T7 11 L2x2x1/8 (40" W 58" Step) 180.00 -
200.00
0.6000 0.6000
T7 12 LDF7-50A(1-5/8) 180.00 -
200.00
0.6000 0.6000
T8 1 Safety Line 3/8 160.00 -
180.00
0.6000 0.6000
T8 2 Step Pegs (5/8" SR) 7-in.
w/30" step
160.00 -
180.00
0.6000 0.6000
T8 4 L2x2x1/8 (40" W 58" Step) 160.00 -
180.00
0.6000 0.6000
T8 5 LDF7-50A(1-5/8) 160.00 -
180.00
0.6000 0.6000
T8 6 3/8" Cable (Lights) 160.00 -
180.00
0.6000 0.6000
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
17 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
T8 9 MLCH 12/24 LOW
INDUCTION(2)
160.00 -
180.00
0.6000 0.6000
T8 11 L2x2x1/8 (40" W 58" Step) 160.00 -
180.00
0.6000 0.6000
T8 12 LDF7-50A(1-5/8) 160.00 -
180.00
0.6000 0.6000
T9 1 Safety Line 3/8 140.00 -
160.00
0.6000 0.6000
T9 2 Step Pegs (5/8" SR) 7-in.
w/30" step
140.00 -
160.00
0.6000 0.6000
T9 4 L2x2x1/8 (40" W 58" Step) 140.00 -
160.00
0.6000 0.6000
T9 5 LDF7-50A(1-5/8) 140.00 -
160.00
0.6000 0.6000
T9 6 3/8" Cable (Lights) 140.00 -
160.00
0.6000 0.6000
T9 9 MLCH 12/24 LOW
INDUCTION(2)
140.00 -
160.00
0.6000 0.6000
T9 11 L2x2x1/8 (40" W 58" Step) 140.00 -
160.00
0.6000 0.6000
T9 12 LDF7-50A(1-5/8) 140.00 -
160.00
0.6000 0.6000
T9 18 D-X wind area 140.00 -
160.00
0.6000 0.6000
T9 19 D-X wind area 140.00 -
160.00
0.6000 0.6000
T9 20 D-X wind area 140.00 -
160.00
0.6000 0.6000
T10 1 Safety Line 3/8 120.00 -
140.00
0.6000 0.6000
T10 2 Step Pegs (5/8" SR) 7-in.
w/30" step
120.00 -
140.00
0.6000 0.6000
T10 4 L2x2x1/8 (40" W 58" Step) 120.00 -
140.00
0.6000 0.6000
T10 5 LDF7-50A(1-5/8) 120.00 -
140.00
0.6000 0.6000
T10 6 3/8" Cable (Lights) 120.00 -
140.00
0.6000 0.6000
T10 8 EW63(ELLIPTICAL) 120.00 -
127.00
0.6000 0.6000
T10 9 MLCH 12/24 LOW
INDUCTION(2)
120.00 -
140.00
0.6000 0.6000
T10 11 L2x2x1/8 (40" W 58" Step) 120.00 -
140.00
0.6000 0.6000
T10 12 LDF7-50A(1-5/8) 120.00 -
140.00
0.6000 0.6000
T10 18 D-X wind area 120.00 -
140.00
0.6000 0.6000
T10 19 D-X wind area 120.00 -
140.00
0.6000 0.6000
T10 20 D-X wind area 120.00 -
140.00
0.6000 0.6000
T11 1 Safety Line 3/8 100.00 -
120.00
0.6000 0.6000
T11 2 Step Pegs (5/8" SR) 7-in.
w/30" step
100.00 -
120.00
0.6000 0.6000
T11 4 L2x2x1/8 (40" W 58" Step) 100.00 -
120.00
0.6000 0.6000
T11 5 LDF7-50A(1-5/8) 100.00 -
120.00
0.6000 0.6000
T11 6 3/8" Cable (Lights) 100.00 -
120.00
0.6000 0.6000
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
18 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
T11 8 EW63(ELLIPTICAL) 100.00 -
120.00
0.6000 0.6000
T11 9 MLCH 12/24 LOW
INDUCTION(2)
100.00 -
120.00
0.6000 0.6000
T11 11 L2x2x1/8 (40" W 58" Step) 100.00 -
120.00
0.6000 0.6000
T11 12 LDF7-50A(1-5/8) 100.00 -
120.00
0.6000 0.6000
T11 13 EW63(ELLIPTICAL) 100.00 -
115.00
0.6000 0.6000
T12 1 Safety Line 3/8 80.00 - 100.00 0.6000 0.6000
T12 2 Step Pegs (5/8" SR) 7-in.
w/30" step
80.00 - 100.00 0.6000 0.6000
T12 4 L2x2x1/8 (40" W 58" Step) 80.00 - 100.00 0.6000 0.6000
T12 5 LDF7-50A(1-5/8) 80.00 - 100.00 0.6000 0.6000
T12 6 3/8" Cable (Lights) 80.00 - 100.00 0.6000 0.6000
T12 8 EW63(ELLIPTICAL) 80.00 - 100.00 0.6000 0.6000
T12 9 MLCH 12/24 LOW
INDUCTION(2)
80.00 - 100.00 0.6000 0.6000
T12 11 L2x2x1/8 (40" W 58" Step) 80.00 - 100.00 0.6000 0.6000
T12 12 LDF7-50A(1-5/8) 80.00 - 100.00 0.6000 0.6000
T12 13 EW63(ELLIPTICAL) 80.00 - 100.00 0.6000 0.6000
T12 15 D-X wind area 80.00 - 100.00 0.6000 0.6000
T12 16 D-X wind area 80.00 - 100.00 0.6000 0.6000
T12 17 D-X wind area 80.00 - 100.00 0.6000 0.6000
T13 1 Safety Line 3/8 60.00 - 80.00 0.6000 0.6000
T13 2 Step Pegs (5/8" SR) 7-in.
w/30" step
60.00 - 80.00 0.6000 0.6000
T13 4 L2x2x1/8 (40" W 58" Step) 60.00 - 80.00 0.6000 0.6000
T13 5 LDF7-50A(1-5/8) 60.00 - 80.00 0.6000 0.6000
T13 6 3/8" Cable (Lights) 60.00 - 80.00 0.6000 0.6000
T13 8 EW63(ELLIPTICAL) 60.00 - 80.00 0.6000 0.6000
T13 9 MLCH 12/24 LOW
INDUCTION(2)
60.00 - 80.00 0.6000 0.6000
T13 11 L2x2x1/8 (40" W 58" Step) 60.00 - 80.00 0.6000 0.6000
T13 12 LDF7-50A(1-5/8) 60.00 - 80.00 0.6000 0.6000
T13 13 EW63(ELLIPTICAL) 60.00 - 80.00 0.6000 0.6000
T13 15 D-X wind area 60.00 - 80.00 0.6000 0.6000
T13 16 D-X wind area 60.00 - 80.00 0.6000 0.6000
T13 17 D-X wind area 60.00 - 80.00 0.6000 0.6000
T14 1 Safety Line 3/8 40.00 - 60.00 0.6000 0.6000
T14 2 Step Pegs (5/8" SR) 7-in.
w/30" step
40.00 - 60.00 0.6000 0.6000
T14 4 L2x2x1/8 (40" W 58" Step) 40.00 - 60.00 0.6000 0.6000
T14 5 LDF7-50A(1-5/8) 40.00 - 60.00 0.6000 0.6000
T14 6 3/8" Cable (Lights) 40.00 - 60.00 0.6000 0.6000
T14 7 9/16" Feedline 40.00 - 59.00 0.6000 0.6000
T14 8 EW63(ELLIPTICAL) 40.00 - 60.00 0.6000 0.6000
T14 9 MLCH 12/24 LOW
INDUCTION(2)
40.00 - 60.00 0.6000 0.6000
T14 11 L2x2x1/8 (40" W 58" Step) 40.00 - 60.00 0.6000 0.6000
T14 12 LDF7-50A(1-5/8) 40.00 - 60.00 0.6000 0.6000
T14 13 EW63(ELLIPTICAL) 40.00 - 60.00 0.6000 0.6000
T15 1 Safety Line 3/8 20.00 - 40.00 0.6000 0.6000
T15 2 Step Pegs (5/8" SR) 7-in.
w/30" step
20.00 - 40.00 0.6000 0.6000
T15 4 L2x2x1/8 (40" W 58" Step) 20.00 - 40.00 0.6000 0.6000
T15 5 LDF7-50A(1-5/8) 20.00 - 40.00 0.6000 0.6000
T15 6 3/8" Cable (Lights) 20.00 - 40.00 0.6000 0.6000
T15 7 9/16" Feedline 20.00 - 40.00 0.6000 0.6000
T15 8 EW63(ELLIPTICAL) 20.00 - 40.00 0.6000 0.6000
T15 9 MLCH 12/24 LOW 20.00 - 40.00 0.6000 0.6000
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
19 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Tower
Section
Feed Line
Record No.
Description Feed Line
Segment Elev.
Ka
No Ice
Ka
Ice
INDUCTION(2)
T15 11 L2x2x1/8 (40" W 58" Step) 20.00 - 40.00 0.6000 0.6000
T15 12 LDF7-50A(1-5/8) 20.00 - 40.00 0.6000 0.6000
T15 13 EW63(ELLIPTICAL) 20.00 - 40.00 0.6000 0.6000
T16 1 Safety Line 3/8 5.00 - 20.00 0.6000 0.6000
T16 2 Step Pegs (5/8" SR) 7-in.
w/30" step
5.00 - 20.00 0.6000 0.6000
T16 4 L2x2x1/8 (40" W 58" Step) 5.00 - 20.00 0.6000 0.6000
T16 5 LDF7-50A(1-5/8) 11.00 - 20.00 0.6000 0.6000
T16 6 3/8" Cable (Lights) 11.00 - 20.00 0.6000 0.6000
T16 7 9/16" Feedline 11.00 - 20.00 0.6000 0.6000
T16 8 EW63(ELLIPTICAL) 11.00 - 20.00 0.6000 0.6000
T16 9 MLCH 12/24 LOW
INDUCTION(2)
11.00 - 20.00 0.6000 0.6000
T16 11 L2x2x1/8 (40" W 58" Step) 5.00 - 20.00 0.6000 0.6000
T16 12 LDF7-50A(1-5/8) 11.00 - 20.00 0.6000 0.6000
T16 13 EW63(ELLIPTICAL) 11.00 - 20.00 0.6000 0.6000
Discrete Tower Loads
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustment
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
5/8''x6-ft LRod B From Leg 0.50
0.00
11.00
0.0000 300.00 No Ice 0.38 0.38 0.01
2.4'' x 16' B From Leg 0.50
0.00
0.00
0.0000 300.00 No Ice 3.84 3.84 0.06
2.4'' Dia. x 3-ft A From Leg 0.00
0.00
1.50
0.0000 300.00 No Ice 0.58 0.58 0.01
8''x15'' Dia. Beacon C From Leg 0.00
0.00
1.00
0.0000 300.00 No Ice 0.42 0.42 0.05
***297***
BCD-80612 A From Leg 6.00
0.00
9.00
0.0000 297.00 No Ice 4.65 4.65 0.08
2.4'' x 8' Pipe A From Face 0.50
0.00
0.00
0.0000 297.00 No Ice 1.90 1.90 0.03
Side Arm Mount [SO 303-1] A From Leg 3.00
0.00
0.00
0.0000 297.00 No Ice 1.08 5.31 0.12
***
VZE01 w/ Mount Pipe A From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 5.36 4.10 0.13
VZE01 w/ Mount Pipe B From Leg 4.00
0.00
0.0000 285.00 No Ice 5.36 4.10 0.13
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
20 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustment
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
3.00
VZE01 w/ Mount Pipe C From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 5.36 4.10 0.13
(2) X7CQAP-665-V w/
Mount Pipe
A From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 8.64 7.00 0.08
(2) X7CQAP-665-V w/
Mount Pipe
B From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 8.64 7.00 0.08
(2) X7CQAP-665-V w/
Mount Pipe
C From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 8.64 7.00 0.08
RADIO 4449 B13/B5 A From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 1.98 1.71 0.07
RADIO 4449 B13/B5 B From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 1.98 1.71 0.07
RADIO 4449 B13/B5 C From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 1.98 1.71 0.07
RADIO 8843 B2/B66A A From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 1.64 1.38 0.08
RADIO 8843 B2/B66A B From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 1.64 1.38 0.08
RADIO 8843 B2/B66A C From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 1.64 1.38 0.08
DBC-67C-U-1SF A From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 0.16 0.07 0.00
DBC-67C-U-1SF B From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 0.16 0.07 0.00
DBC-67C-U-1SF C From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 0.16 0.07 0.00
RHSDC-6627-PF-48 A From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 4.06 3.10 0.03
RHSDC-6627-PF-48 B From Leg 4.00
0.00
3.00
0.0000 285.00 No Ice 4.06 3.10 0.03
3.5'' Dia. x 12.5-ft Pipe A From Leg 2.00
0.00
0.00
0.0000 285.00 No Ice 3.05 3.05 0.09
3.5'' Dia. x 12.5-ft Pipe B From Leg 2.00
0.00
0.00
0.0000 285.00 No Ice 3.05 3.05 0.09
3.5'' Dia. x 12.5-ft Pipe C From Leg 2.00
0.00
0.00
0.0000 285.00 No Ice 3.05 3.05 0.09
(2) Miscellaneous [NA 509-1] A From Leg 2.00
0.00
0.0000 285.00 No Ice 6.32 4.85 0.09
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
21 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Description Face
or
Leg
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
ft
ft
Azimuth
Adjustment
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
0.00
(2) Miscellaneous [NA 509-1] B From Leg 2.00
0.00
0.00
0.0000 285.00 No Ice 6.32 4.85 0.09
(2) Miscellaneous [NA 509-1] C From Leg 2.00
0.00
0.00
0.0000 285.00 No Ice 6.32 4.85 0.09
Sector Mount [SM 1305-3] C None 0.0000 285.00 No Ice 31.68 31.68 1.25
***
HSS 4x4 (8-ft long) A From Face 0.50
0.00
0.00
0.0000 178.50 No Ice 5.24 5.24 0.01
***
(2) 1.9in dia x 8-ft B From Face 0.50
0.00
0.00
0.0000 127.00 No Ice 1.52 1.52 0.02
Pipe Mount [PM 601-1] A From Leg 0.50
0.00
0.00
0.0000 127.00 No Ice 1.32 1.32 0.07
***
1.9in dia x 8-ft B From Face 0.50
0.00
0.00
0.0000 115.00 No Ice 1.52 1.52 0.02
Pipe Mount [PM 601-1] A From Leg 0.50
0.00
0.00
0.0000 115.00 No Ice 1.32 1.32 0.07
Dishes
Description Face
or
Leg
Dish
Type
Offset
Type
Offsets:
Horz
Lateral
Vert
ft
Azimuth
Adjustment
°
3 dB
Beam
Width
°
Elevation
ft
Outside
Diameter
ft
Aperture
Area
ft2
Weight
K
UHX6-59-P3A/L A Paraboloid
w/Shroud (HP)
From
Leg
1.00
0.00
0.00
30.0000 127.00 6.46 No Ice 32.76 0.32
P4-57W-PXA A Paraboloid
w/Radome
From
Leg
1.00
0.00
0.00
30.0000 115.00 4.37 No Ice 14.98 0.17
Load Combinations
Comb.
No.
Description
1 Dead Only
2 1.2 Dead+1.0 Wind 0 deg - No Ice+1.0 Guy
3 1.2 Dead+1.0 Wind 30 deg - No Ice+1.0 Guy
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
22 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Comb.
No.
Description
4 1.2 Dead+1.0 Wind 60 deg - No Ice+1.0 Guy
5 1.2 Dead+1.0 Wind 90 deg - No Ice+1.0 Guy
6 1.2 Dead+1.0 Wind 120 deg - No Ice+1.0 Guy
7 1.2 Dead+1.0 Wind 150 deg - No Ice+1.0 Guy
8 1.2 Dead+1.0 Wind 180 deg - No Ice+1.0 Guy
9 1.2 Dead+1.0 Wind 210 deg - No Ice+1.0 Guy
10 1.2 Dead+1.0 Wind 240 deg - No Ice+1.0 Guy
11 1.2 Dead+1.0 Wind 270 deg - No Ice+1.0 Guy
12 1.2 Dead+1.0 Wind 300 deg - No Ice+1.0 Guy
13 1.2 Dead+1.0 Wind 330 deg - No Ice+1.0 Guy
14 Dead+Wind 0 deg - Service+Guy
15 Dead+Wind 30 deg - Service+Guy
16 Dead+Wind 60 deg - Service+Guy
17 Dead+Wind 90 deg - Service+Guy
18 Dead+Wind 120 deg - Service+Guy
19 Dead+Wind 150 deg - Service+Guy
20 Dead+Wind 180 deg - Service+Guy
21 Dead+Wind 210 deg - Service+Guy
22 Dead+Wind 240 deg - Service+Guy
23 Dead+Wind 270 deg - Service+Guy
24 Dead+Wind 300 deg - Service+Guy
25 Dead+Wind 330 deg - Service+Guy
Maximum Tower Deflections - Service Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
T1 300 - 287.341 3.372 24 0.1673 0.9354
T2 287.341 - 280 3.055 24 0.1596 0.8840
T3 280 - 260 2.888 24 0.1421 0.8743
T4 260 - 240 2.582 24 0.1022 0.7375
T5 240 - 220 2.282 24 0.0795 0.5666
T6 220 - 200 1.992 24 0.0467 0.4696
T7 200 - 180 1.860 24 0.0182 0.4636
T8 180 - 160 1.817 24 0.0160 0.5488
T9 160 - 140 1.708 24 0.0353 0.6944
T10 140 - 120 1.554 24 0.0240 0.7302
T11 120 - 100 1.507 18 0.0235 0.7651
T12 100 - 80 1.411 18 0.0445 0.6947
T13 80 - 60 1.228 18 0.0362 0.6431
T14 60 - 40 1.133 18 0.0351 0.5890
T15 40 - 20 0.936 18 0.0711 0.4551
T16 20 - 4.81771 0.540 18 0.1108 0.2972
T17 4.81771 - 0 0.131 18 0.1273 0.1584
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
300.00 5/8''x6-ft LRod 24 3.372 0.1673 0.9354 144604
297.00 BCD-80612 24 3.296 0.1671 0.9199 144604
285.00 VZE01 w/ Mount Pipe 24 2.999 0.1548 0.8810 28991
279.39 Guy 24 2.875 0.1406 0.8726 15862
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
23 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
209.75 Guy 24 1.904 0.0301 0.4556 25641
178.50 HSS 4x4 (8-ft long) 24 1.813 0.0173 0.5597 47294
139.39 Guy 24 1.551 0.0236 0.7312 28449
127.00 UHX6-59-P3A/L 24 1.513 0.0200 0.7602 46821
115.00 P4-57W-PXA 18 1.499 0.0288 0.7555 23667
79.39 Guy 18 1.224 0.0358 0.6419 24811
Maximum Tower Deflections - Design Wind
Section
No.
Elevation
ft
Horz.
Deflection
in
Gov.
Load
Comb.
Tilt
°
Twist
°
T1 300 - 287.341 47.050 6 1.4976 3.4951
T2 287.341 - 280 43.685 6 1.4716 3.2939
T3 280 - 260 41.803 6 1.3830 3.2620
T4 260 - 240 37.475 6 1.1852 3.0563
T5 240 - 220 33.232 6 1.0328 2.6490
T6 220 - 200 29.386 6 0.7173 2.3548
T7 200 - 180 26.878 6 0.4880 2.3734
T8 180 - 160 25.167 6 0.4190 2.7951
T9 160 - 140 23.326 6 0.4650 3.4443
T10 140 - 120 21.430 6 0.3623 3.5812
T11 120 - 100 20.162 6 0.3679 3.7658
T12 100 - 80 18.207 6 0.5562 3.3986
T13 80 - 60 15.621 6 0.5574 3.1047
T14 60 - 40 13.432 6 0.6377 2.8694
T15 40 - 20 10.343 6 0.9247 2.2515
T16 20 - 4.81771 5.713 6 1.2292 1.4741
T17 4.81771 - 0 1.385 6 1.3529 0.7931
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov.
Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius of
Curvature
ft
300.00 5/8''x6-ft LRod 6 47.050 1.4976 3.4951 43746
297.00 BCD-80612 6 46.250 1.5008 3.4339 43746
285.00 VZE01 w/ Mount Pipe 6 43.071 1.4477 3.2809 5901
279.39 Guy 6 41.654 1.3750 3.2593 2909
209.75 Guy 6 27.940 0.5822 2.3189 3726
178.50 HSS 4x4 (8-ft long) 6 25.040 0.4216 2.8456 8581
139.39 Guy 6 21.384 0.3592 3.5864 4297
127.00 UHX6-59-P3A/L 6 20.609 0.3372 3.7371 9129
115.00 P4-57W-PXA 6 19.772 0.4119 3.7186 3937
79.39 Guy 6 15.549 0.5563 3.0987 3894
Bolt Design Data
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
24 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Component
Type
Bolt
Grade
Bolt Size
in
Number
Of
Bolts
Maximum
Load
per Bolt
K
Allowable
Load
per Bolt
K
Ratio
Load
Allowable
Allowable
Ratio
Criteria
T1 300 Diagonal A325X 0.5000 1 3.00 5.92 0.507 1.05 Member Bearing
Top Girt A325X 0.5000 1 0.34 5.92 0.057 1.05 Member Bearing
T2 287.341 Leg A325X 0.7500 4 8.14 30.10 0.270 1.05 Bolt Tension
Diagonal A325X 0.5000 1 6.79 8.59 0.790 1.05 Gusset Bearing
Top Girt A325X 0.5000 1 1.60 8.59 0.187 1.05 Gusset Bearing
Bottom Girt A325X 0.6250 1 2.60 8.70 0.299 1.05 Gusset Bearing
T3 280 Leg A325X 0.7500 4 2.25 30.10 0.075 1.05 Bolt Tension
Diagonal A325X 0.5000 1 4.02 5.92 0.679 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 0.99 5.92 0.167 1.05 Member Bearing
Top Guy
Pull-Off@279.38
5
A325X 0.6250 2 6.66 8.43 0.790 1.05 Member Block
Shear
T4 260 Leg A325X 0.7500 4 2.79 30.10 0.093 1.05 Bolt Tension
Diagonal A325X 0.5000 1 2.94 5.92 0.496 1.05 Member Bearing
Top Girt A325X 0.5000 1 0.88 5.92 0.149 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.51 5.92 0.256 1.05 Member Bearing
T5 240 Leg A325X 0.7500 4 4.80 30.10 0.159 1.05 Bolt Tension
Diagonal A325X 0.5000 1 2.84 5.92 0.480 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.00 5.92 0.169 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.00 5.92 0.169 1.05 Member Bearing
T6 220 Leg A325X 0.7500 4 4.96 30.10 0.165 1.05 Bolt Tension
Diagonal A325X 0.5000 1 5.61 9.78 0.573 1.05 Gusset Bearing
Top Girt A325X 0.5000 1 1.40 5.92 0.237 1.05 Member Bearing
Bottom Girt A325X 0.6250 1 1.40 9.91 0.142 1.05 Gusset Bearing
Torque Arm
Top@209.75
A325X 0.6250 2 6.09 11.07 0.551 1.05 Gusset Bearing
T7 200 Leg A325X 0.7500 4 3.04 30.10 0.101 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.13 5.92 0.529 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.03 5.92 0.174 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.03 5.92 0.174 1.05 Member Bearing
T8 180 Leg A325X 0.7500 4 2.97 30.10 0.099 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.25 5.92 0.548 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.36 5.92 0.229 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.17 5.92 0.197 1.05 Member Bearing
T9 160 Leg A325X 0.7500 4 4.91 30.10 0.163 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.73 9.78 0.382 1.05 Gusset Bearing
Top Girt A325X 0.5000 1 1.02 5.92 0.173 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.12 5.92 0.189 1.05 Member Bearing
T10 140 Leg A325X 0.7500 4 4.34 30.10 0.144 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.60 5.92 0.609 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.18 5.92 0.200 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.02 5.92 0.173 1.05 Member Bearing
Top Guy
Pull-Off@139.38
5
A325X 0.7500 2 3.80 23.82 0.160 1.05 Gusset Bearing
T11 120 Leg A325X 0.7500 4 4.09 30.10 0.136 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.12 5.92 0.527 1.05 Member Bearing
Top Girt A325X 0.5000 1 0.93 5.92 0.158 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.35 5.92 0.228 1.05 Member Bearing
T12 100 Leg A325X 0.7500 4 5.02 30.10 0.167 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.65 7.02 0.521 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.04 5.92 0.176 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.07 5.92 0.181 1.05 Member Bearing
T13 80 Leg A325X 0.7500 4 5.06 30.10 0.168 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.51 5.92 0.593 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.29 5.92 0.217 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.05 5.92 0.178 1.05 Member Bearing
Top Guy
Pull-Off@79.385
4
A325X 0.7500 2 4.13 23.82 0.173 1.05 Gusset Bearing
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
25 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Component
Type
Bolt
Grade
Bolt Size
in
Number
Of
Bolts
Maximum
Load
per Bolt
K
Allowable
Load
per Bolt
K
Ratio
Load
Allowable
Allowable
Ratio
Criteria
T14 60 Leg A325X 0.7500 4 6.10 30.10 0.203 1.05 Bolt Tension
Diagonal A325X 0.5000 1 4.55 5.92 0.768 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.75 5.92 0.296 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.28 5.92 0.217 1.05 Member Bearing
T15 40 Leg A325X 0.7500 4 5.50 30.10 0.183 1.05 Bolt Tension
Diagonal A325X 0.5000 1 3.79 5.92 0.640 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.29 5.92 0.218 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.39 5.92 0.235 1.05 Member Bearing
T16 20 Diagonal A325X 0.5000 1 4.67 5.92 0.789 1.05 Member Bearing
Top Girt A325X 0.5000 1 1.64 5.92 0.278 1.05 Member Bearing
Bottom Girt A325X 0.5000 1 1.68 5.92 0.285 1.05 Member Bearing
Guy Design Data
Section
No.
Elevation
ft
Size
Initial
Tension
K
Breaking
Load
K
Actual
Tu
K
Allowable
Tn
K
Required
S.F.
Actual
S.F.
T3 279.39 (A)
(690)
3/4 EHS 7.00 58.30 35.33 36.73 0.952 0.990
279.39 (B)
(689)
3/4 EHS 7.00 58.30 35.71 36.73 0.952 0.980
279.39 (C)
(688)
3/4 EHS 7.00 58.30 35.59 36.73 0.952 0.983
T6 209.75 (A)
(699)
9/16 EHS 2.45 35.00 15.48 22.05 0.952 1.357
209.75 (A)
(700)
9/16 EHS 2.45 35.00 16.16 22.05 0.952 1.299
209.75 (B)
(695)
9/16 EHS 2.45 35.00 15.94 22.05 0.952 1.317
209.75 (B)
(696)
9/16 EHS 2.45 35.00 16.98 22.05 0.952 1.237
209.75 (C)
(691)
9/16 EHS 2.45 35.00 16.93 22.05 0.952 1.240
209.75 (C)
(692)
9/16 EHS 2.45 35.00 14.48 22.05 0.952 1.451
T10 139.39 (A)
(708)
9/16 EHS 3.50 35.00 18.67 22.05 0.952 1.125
139.39 (B)
(707)
9/16 EHS 3.50 35.00 18.76 22.05 0.952 1.119
139.39 (C)
(703)
9/16 EHS 3.50 35.00 18.33 22.05 0.952 1.146
T13 79.39 (A)
(714)
9/16 EHS 3.50 35.00 17.38 22.05 0.952 1.208
79.39 (B) (713) 9/16 EHS 3.50 35.00 17.41 22.05 0.952 1.206
79.39 (C) (709) 9/16 EHS 3.50 35.00 17.14 22.05 0.952 1.225
Compression Checks
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
26 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Leg Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 287.341 ROHN 2 X-STR 12.66 2.41 75.4
K=2.00
1.4773 -7.16 43.86 0.163 1
T2 287.341 - 280 ROHN 2 X-STR 7.34 0.11 1.8
K=1.00
1.4773 -35.95 66.46 0.541 1
T3 280 - 260 ROHN 2 X-STR 20.00 2.41 75.4
K=2.00
1.4773 -36.75 43.86 0.838 1
T4 260 - 240 ROHN 2 X-STR 20.00 2.41 75.4
K=2.00
1.4773 -33.30 43.86 0.759 1
T5 240 - 220 ROHN 2 X-STR 20.00 2.41 37.7
K=1.00
1.4773 -55.14 59.91 0.920 1
T6 220 - 200 ROHN 2.5 EH w/ 3XS Half
Sleeve
20.00 2.41 31.3
K=1.00
3.7610 -81.08 157.58 0.515 1
T7 200 - 180 ROHN 2 X-STR w/ 3''
X-STR Half-Sleeve
20.00 2.41 38.6
K=1.00
2.9852 -57.11 120.45 0.474 1
T8 180 - 160 ROHN 2 X-STR 20.00 2.41 75.4
K=2.00
1.4773 -37.66 43.86 0.859 1
T9 160 - 140 ROHN 2.5 STD 20.00 2.41 30.5
K=1.00
1.7040 -55.70 71.64 0.778 1
T10 140 - 120 ROHN 2.5 STD 20.00 2.41 30.5
K=1.00
1.7040 -56.17 71.64 0.784 1
T11 120 - 100 ROHN 2.5 STD 20.00 2.41 61.0
K=2.00
1.7040 -53.97 58.41 0.924 1
T12 100 - 80 ROHN 2.5 STD 20.00 2.41 30.5
K=1.00
1.7040 -56.78 71.64 0.793 1
T13 80 - 60 ROHN 2.5 STD 20.00 2.41 30.5
K=1.00
1.7040 -58.93 71.64 0.823 1
T14 60 - 40 ROHN 2.5 X STR 20.00 2.41 63.1
K=2.00
2.4278 -74.09 81.69 0.907 1
T15 40 - 20 ROHN 2.5 X STR 20.00 2.41 63.1
K=2.00
2.4278 -74.36 81.69 0.910 1
T16 20 - 4.81771 ROHN 2.5 X STR 15.18 2.41 63.1
K=2.00
2.4278 -64.98 81.69 0.795 1
T17 4.81771 - 0 ROHN 2.5 X STR 5.21 1.30 17.0
K=1.00
2.4278 -57.10 106.96 0.534 1
1 P u / Pn controls
Diagonal Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 287.341 ROHN 1.5 x 16GA 4.18 3.94 92.6
K=1.00
0.2627 -2.96 5.86 0.505 1
T2 287.341 - 280 L2x2x1/4 4.18 3.71 116.9
K=1.03
0.9380 -6.79 19.64 0.345 1
T3 280 - 260 ROHN 1.5 x 16GA 4.18 3.94 92.6
K=1.00
0.2627 -3.95 5.86 0.674 1
T4 260 - 240 ROHN 1.5 x 16GA 4.18 3.94 92.6
K=1.00
0.2627 -3.18 5.86 0.543 1
T5 240 - 220 ROHN 1.5 x 16GA 4.18 3.94 92.6
K=1.00
0.2627 -3.30 5.86 0.563 1
T6 220 - 200 ROHN 1.5 x 11GA 4.18 3.82 93.7 0.5202 -5.61 11.47 0.489 1
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
27 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
K=1.00
T7 200 - 180 ROHN 1.5 x 16GA 4.18 3.94 92.6
K=1.00
0.2627 -3.57 5.86 0.608 1
T8 180 - 160 ROHN 1.5 x 16GA 4.18 3.94 92.6
K=1.00
0.2627 -3.12 5.86 0.532 1
T9 160 - 140 ROHN 1.5 x 11GA 4.18 3.89 95.2
K=1.00
0.5202 -3.73 11.26 0.331 1
T10 140 - 120 ROHN 1.5 x 16GA 4.18 3.89 91.4
K=1.00
0.2627 -3.64 5.94 0.612 1
T11 120 - 100 ROHN 1.5 x 16GA 4.18 3.89 91.4
K=1.00
0.2627 -3.44 5.94 0.579 1
T12 100 - 80 ROHN 1.5 x 16GA 4.18 3.89 91.4
K=1.00
0.2627 -3.65 5.94 0.615 1
T13 80 - 60 ROHN 1.5 x 16GA 4.18 3.89 91.4
K=1.00
0.2627 -3.38 5.94 0.568 1
T14 60 - 40 ROHN 1.5 x 16GA 4.18 3.89 91.4
K=1.00
0.2627 -4.70 5.94 0.791 1
T15 40 - 20 ROHN 1.5 x 16GA 4.18 3.89 91.4
K=1.00
0.2627 -4.19 5.94 0.705 1
T16 20 - 4.81771 ROHN 1.5 x 16GA 4.18 3.89 91.4
K=1.00
0.2627 -4.75 5.94 0.800 1
1 P u / Pn controls
Horizontal Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T17 4.81771 - 0 L4x4x1/4 2.56 2.32 77.5
K=2.21
1.9400 -1.05 63.47 0.016 1
1 P u / Pn controls
Top Girt Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 287.341 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -0.34 6.99 0.048 1
T2 287.341 - 280 L2x2x1/4 3.42 2.99 105.9
K=1.15
0.9380 -1.60 23.94 0.067 1
T4 260 - 240 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -0.87 6.99 0.124 1
T5 240 - 220 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -1.00 6.99 0.143 1
T6 220 - 200 ROHN 1.5 x 16GA 3.42 3.13 73.5
K=1.00
0.2627 -1.40 7.13 0.197 1
T7 200 - 180 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -1.03 6.99 0.148 1
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
28 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T8 180 - 160 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -1.26 6.99 0.180 1
T9 160 - 140 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.02 7.05 0.145 1
T10 140 - 120 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.02 7.05 0.145 1
T11 120 - 100 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -0.93 7.05 0.133 1
T12 100 - 80 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.04 7.05 0.148 1
T13 80 - 60 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.05 7.05 0.149 1
T14 60 - 40 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.72 7.05 0.244 1
T15 40 - 20 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.29 7.05 0.183 1
T16 20 - 4.81771 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.37 7.05 0.194 1
T17 4.81771 - 0 L4x4x1/4 3.42 3.18 84.0
K=1.75
1.9400 -1.05 60.37 0.017 1
1 P u / Pn controls
Bottom Girt Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T2 287.341 - 280 L2x2x1/4 3.42 2.98 105.7
K=1.16
0.9380 -2.03 24.01 0.085 1
T3 280 - 260 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -0.87 6.99 0.125 1
T4 260 - 240 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -1.32 6.99 0.189 1
T5 240 - 220 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -1.00 6.99 0.143 1
T6 220 - 200 L2 1/2x2 1/2x1/4 3.42 2.89 95.3
K=1.35
1.1900 -1.40 30.62 0.046 1
T7 200 - 180 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -1.03 6.99 0.148 1
T8 180 - 160 ROHN 1.5 x 16GA 3.42 3.22 75.7
K=1.00
0.2627 -1.31 6.99 0.187 1
T9 160 - 140 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.02 7.05 0.145 1
T10 140 - 120 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.02 7.05 0.145 1
T11 120 - 100 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.22 7.05 0.173 1
T12 100 - 80 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.04 7.05 0.148 1
T13 80 - 60 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.05 7.05 0.149 1
T14 60 - 40 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.28 7.05 0.182 1
T15 40 - 20 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.29 7.05 0.183 1
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
29 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T16 20 - 4.81771 ROHN 1.5 x 16GA 3.42 3.18 74.7
K=1.00
0.2627 -1.14 7.05 0.162 1
1 P u / Pn controls
Top Guy Pull-Off Design Data (Compression)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T3 280 - 260 L2x2x1/4 3.42 2.81 103.2
K=1.20
0.9380 -0.37 22.47 0.017 1
1 P u / Pn controls
Top Guy Pull-Off Bending Design Data
Section
No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
T3 280 - 260 L2x2x1/4 0.00 1.69 0.000 0.00 0.87 0.000
Top Guy Pull-Off Interaction Design Data
Section
No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
T3 280 - 260 L2x2x1/4 0.017 0.000 0.000 0.017 1 1.050 4.8.1
1 P u / Pn controls
Torque-Arm Top Design Data
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 220 - 200 (693) C12x20.7 3.50 3.35 50.4
K=1.00
6.0900 -1.44 172.64 0.008
T6 220 - 200 (694) C12x20.7 3.50 3.35 50.4
K=1.00
6.0900 -0.32 172.64 0.002
T6 220 - 200 (697) C12x20.7 3.50 3.35 50.4
K=1.00
6.0900 -3.60 172.64 0.021
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
30 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 220 - 200 (698) C12x20.7 3.50 3.35 50.4
K=1.00
6.0900 -4.36 172.64 0.025
T6 220 - 200 (701) C12x20.7 3.50 3.35 50.4
K=1.00
6.0900 -4.88 172.64 0.028
T6 220 - 200 (702) C12x20.7 3.50 3.35 50.4
K=1.00
6.0900 -5.03 172.64 0.029
Torque-Arm Top Bending Design Data
Section
No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
T6 220 - 200 (693) C12x20.7 -36.60 68.50 0.534 0.00 7.01 0.000
T6 220 - 200 (694) C12x20.7 -38.44 68.50 0.561 -0.00 7.01 0.000
T6 220 - 200 (697) C12x20.7 -38.54 68.50 0.563 0.00 7.01 0.000
T6 220 - 200 (698) C12x20.7 -35.06 68.50 0.512 -0.00 7.01 0.000
T6 220 - 200 (701) C12x20.7 -38.71 68.50 0.565 0.00 7.01 0.000
T6 220 - 200 (702) C12x20.7 -36.96 68.50 0.540 0.00 7.01 0.000
Torque-Arm Top Interaction Design Data
Section
No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
T6 220 - 200 (693) C12x20.7 0.008 0.534 0.000 0.539 1.050 4.8.1
T6 220 - 200 (694) C12x20.7 0.002 0.561 0.000 0.562 1.050 4.8.1
T6 220 - 200 (697) C12x20.7 0.021 0.563 0.000 0.573 1.050 4.8.1
T6 220 - 200 (698) C12x20.7 0.025 0.512 0.000 0.524 1.050 4.8.1
T6 220 - 200 (701) C12x20.7 0.028 0.565 0.000 0.579 1.050 4.8.1
T6 220 - 200 (702) C12x20.7 0.029 0.540 0.000 0.554 1.050 4.8.1
Tension Checks
Leg Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 287.341 ROHN 2 X-STR 12.66 2.41 37.7 1.4773 7.17 66.48 0.108 1
T2 287.341 - 280 ROHN 2 X-STR 7.34 0.11 1.8 1.4773 32.57 66.48 0.490 1
T3 280 - 260 ROHN 2 X-STR 20.00 0.61 9.6 1.4773 32.58 66.48 0.490 1
T5 240 - 220 ROHN 2 X-STR 20.00 0.11 1.8 1.4773 14.47 66.48 0.218 1
T6 220 - 200 ROHN 2.5 EH w/ 3XS Half
Sleeve
20.00 2.41 31.3 3.7610 36.67 169.25 0.217 1
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
31 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
1 P u / Pn controls
Diagonal Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 287.341 ROHN 1.5 x 16GA 4.18 3.94 92.6 0.2627 3.00 9.93 0.302 1
T2 287.341 - 280 L2x2x1/4 4.18 3.71 77.6 0.5863 6.67 28.58 0.233 1
T3 280 - 260 ROHN 1.5 x 16GA 4.18 3.94 92.6 0.2627 4.02 9.93 0.405 1
T4 260 - 240 ROHN 1.5 x 16GA 4.18 3.94 92.6 0.2627 2.94 9.93 0.296 1
T5 240 - 220 ROHN 1.5 x 16GA 4.18 3.94 92.6 0.2627 2.84 9.93 0.286 1
T6 220 - 200 ROHN 1.5 x 11GA 4.18 3.82 93.7 0.5202 5.57 19.67 0.283 1
T7 200 - 180 ROHN 1.5 x 16GA 4.18 3.94 92.6 0.2627 3.13 9.93 0.315 1
T8 180 - 160 ROHN 1.5 x 16GA 4.18 3.94 92.6 0.2627 3.25 9.93 0.327 1
T9 160 - 140 ROHN 1.5 x 11GA 4.18 3.89 95.2 0.5202 2.79 19.67 0.142 1
T10 140 - 120 ROHN 1.5 x 16GA 4.18 3.89 91.4 0.2627 3.60 9.93 0.363 1
T11 120 - 100 ROHN 1.5 x 16GA 4.18 3.89 91.4 0.2627 3.12 9.93 0.314 1
T12 100 - 80 ROHN 1.5 x 16GA 4.18 3.89 91.4 0.2627 3.01 9.93 0.303 1
T13 80 - 60 ROHN 1.5 x 16GA 4.18 3.89 91.4 0.2627 3.51 9.93 0.353 1
T14 60 - 40 ROHN 1.5 x 16GA 4.18 3.89 91.4 0.2627 4.55 9.93 0.458 1
T15 40 - 20 ROHN 1.5 x 16GA 4.18 3.89 91.4 0.2627 3.79 9.93 0.382 1
T16 20 - 4.81771 ROHN 1.5 x 16GA 4.18 3.89 91.4 0.2627 4.67 9.93 0.470 1
1 P u / Pn controls
Horizontal Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T17 4.81771 - 0 L4x4x1/4 0.85 0.61 5.9 1.4550 1.05 70.93 0.015 1
1 P u / Pn controls
Top Girt Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T1 300 - 287.341 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 0.34 9.93 0.034 1
T2 287.341 - 280 L2x2x1/4 3.42 2.99 63.4 0.5863 1.53 28.58 0.054 1
T4 260 - 240 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 0.88 9.93 0.089 1
T5 240 - 220 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 1.00 9.93 0.100 1
T6 220 - 200 ROHN 1.5 x 16GA 3.42 3.13 73.5 0.2627 1.40 9.93 0.141 1
T7 200 - 180 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 1.03 9.93 0.104 1
T8 180 - 160 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 1.36 9.93 0.136 1
T9 160 - 140 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.02 9.93 0.103 1
T10 140 - 120 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.18 9.93 0.119 1
T11 120 - 100 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 0.93 9.93 0.094 1
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
32 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T12 100 - 80 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.04 9.93 0.105 1
T13 80 - 60 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.29 9.93 0.129 1
T14 60 - 40 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.75 9.93 0.176 1
T15 40 - 20 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.29 9.93 0.130 1
T16 20 - 4.81771 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.64 9.93 0.166 1
T17 4.81771 - 0 L4x4x1/4 3.42 3.18 30.5 1.4550 11.16 70.93 0.157 1
1 P u / Pn controls
Bottom Girt Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T2 287.341 - 280 L2x2x1/4 3.42 2.98 63.4 0.5629 2.60 27.44 0.095 1
T3 280 - 260 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 0.99 9.93 0.099 1
T4 260 - 240 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 1.51 9.93 0.152 1
T5 240 - 220 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 1.00 9.93 0.100 1
T6 220 - 200 L2 1/2x2 1/2x1/4 3.42 2.89 48.8 0.7519 1.40 32.71 0.043 1
T7 200 - 180 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 1.03 9.93 0.104 1
T8 180 - 160 ROHN 1.5 x 16GA 3.42 3.22 75.7 0.2627 1.17 9.93 0.118 1
T9 160 - 140 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.12 9.93 0.113 1
T10 140 - 120 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.02 9.93 0.103 1
T11 120 - 100 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.35 9.93 0.136 1
T12 100 - 80 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.07 9.93 0.108 1
T13 80 - 60 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.05 9.93 0.106 1
T14 60 - 40 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.28 9.93 0.129 1
T15 40 - 20 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.39 9.93 0.140 1
T16 20 - 4.81771 ROHN 1.5 x 16GA 3.42 3.18 74.7 0.2627 1.68 9.93 0.170 1
1 P u / Pn controls
Top Guy Pull-Off Design Data (Tension)
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T3 280 - 260 L2x2x1/4 3.42 2.81 63.4 0.5629 13.32 24.49 0.544 1
T10 140 - 120 4.5x3/8 3.42 3.18 352.2 1.6875 7.60 54.67 0.139 1
T13 80 - 60 4.5x3/8 3.42 3.18 352.2 1.6875 8.26 54.67 0.151 1
1 P u / Pn controls
Top Guy Pull-Off Bending Design Data
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
33 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
T3 280 - 260 L2x2x1/4 0.00 1.69 0.000 0.00 0.87 0.000
T10 140 - 120 4.5x3/8 0.00 5.13 0.000 0.00 0.43 0.000
T13 80 - 60 4.5x3/8 0.00 5.13 0.000 0.00 0.43 0.000
Top Guy Pull-Off Interaction Design Data
Section
No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
T3 280 - 260 L2x2x1/4 0.544 0.000 0.000 0.544 1 1.050 4.8.1
T10 140 - 120 4.5x3/8 0.139 0.000 0.000 0.139 1 1.050 4.8.1
T13 80 - 60 4.5x3/8 0.151 0.000 0.000 0.151 1 1.050 4.8.1
1 P u / Pn controls
Torque-Arm Top Design Data
Section
No.
Elevation
ft
Size
L
ft
Lu
ft
Kl/r
A
in2
Pu
K
Pn
K
Ratio
Pu
Pn
T6 220 - 200 (693) C12x20.7 3.50 3.35 50.4 4.4089 4.36 191.79 0.023
T6 220 - 200 (694) C12x20.7 3.50 3.35 50.4 4.4089 5.85 191.79 0.031
T6 220 - 200 (697) C12x20.7 3.50 3.35 50.4 4.4089 3.52 191.79 0.018
T6 220 - 200 (698) C12x20.7 3.50 3.35 50.4 4.4089 1.37 191.79 0.007
T6 220 - 200 (701) C12x20.7 3.50 3.35 50.4 4.4089 2.83 191.79 0.015
T6 220 - 200 (702) C12x20.7 3.50 3.35 50.4 4.4089 5.66 191.79 0.029
Torque-Arm Top Bending Design Data
Section
No.
Elevation
ft
Size
Mux
kip-ft
Mnx
kip-ft
Ratio
Mux
Mnx
Muy
kip-ft
Mny
kip-ft
Ratio
Muy
Mny
T6 220 - 200 (693) C12x20.7 -34.48 68.50 0.503 0.00 7.01 0.000
T6 220 - 200 (694) C12x20.7 -37.09 68.50 0.541 0.00 7.01 0.000
T6 220 - 200 (697) C12x20.7 -29.10 68.50 0.425 0.00 7.01 0.000
T6 220 - 200 (698) C12x20.7 -33.01 68.50 0.482 0.00 7.01 0.000
T6 220 - 200 (701) C12x20.7 -28.06 68.50 0.410 -0.00 7.01 0.000
T6 220 - 200 (702) C12x20.7 -32.86 68.50 0.480 -0.00 7.01 0.000
Torque-Arm Top Interaction Design Data
Section
No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
T6 220 - 200 (693) C12x20.7 0.023 0.503 0.000 0.515 1.050 4.8.1
T6 220 - 200 (694) C12x20.7 0.031 0.541 0.000 0.557 1.050 4.8.1
T6 220 - 200 (697) C12x20.7 0.018 0.425 0.000 0.434 1.050 4.8.1
T6 220 - 200 (698) C12x20.7 0.007 0.482 0.000 0.485 1.050 4.8.1
T6 220 - 200 (701) C12x20.7 0.015 0.410 0.000 0.417 1.050 4.8.1
T6 220 - 200 (702) C12x20.7 0.029 0.480 0.000 0.494 1.050 4.8.1
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
34 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Size
Ratio
Pu
Pn
Ratio
Mux
Mnx
Ratio
Muy
Mny
Comb.
Stress
Ratio
Allow.
Stress
Ratio
Criteria
Section Capacity Table
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
T1 300 - 287.341 Leg ROHN 2 X-STR 2 -7.16 46.05 15.6 Pass
T2 287.341 - 280 Leg ROHN 2 X-STR 23 -35.95 69.78 51.5 Pass
T3 280 - 260 Leg ROHN 2 X-STR 50 -36.75 46.05 79.8 Pass
T4 260 - 240 Leg ROHN 2 X-STR 82 -33.30 46.05 72.3 Pass
T5 240 - 220 Leg ROHN 2 X-STR 115 -55.14 62.91 87.6 Pass
T6 220 - 200 Leg ROHN 2.5 EH w/ 3XS Half
Sleeve
Note 1 Note 1 Note 1 77.4 Pass
T7 200 - 180 Leg ROHN 2 X-STR w/ 3'' X-STR
Half-Sleeve
Note 1 Note 1 Note 1 64.3 Pass
T8 180 - 160 Leg ROHN 2 X-STR 286 -37.66 46.05 81.8 Pass
T9 160 - 140 Leg ROHN 2.5 STD 320 -55.70 75.22 74.0 Pass
T10 140 - 120 Leg ROHN 2.5 STD 377 -56.17 75.22 74.7 Pass
T11 120 - 100 Leg ROHN 2.5 STD 435 -53.97 61.33 88.0 Pass
T12 100 - 80 Leg ROHN 2.5 STD 467 -56.78 75.22 75.5 Pass
T13 80 - 60 Leg ROHN 2.5 STD 523 -58.93 75.22 78.4 Pass
T14 60 - 40 Leg ROHN 2.5 X STR 581 -74.09 85.78 86.4 Pass
T15 40 - 20 Leg ROHN 2.5 X STR 614 -74.36 85.78 86.7 Pass
T16 20 - 4.81771 Leg ROHN 2.5 X STR 646 -64.98 85.78 75.8 Pass
T17 4.81771 - 0 Leg ROHN 2.5 X STR 673 -57.10 112.31 50.8 Pass
T1 300 - 287.341 Diagonal ROHN 1.5 x 16GA 11 -2.96 6.16 48.1 Pass
T2 287.341 - 280 Diagonal L2x2x1/4 33 -6.79 20.62 32.9 Pass
T3 280 - 260 Diagonal ROHN 1.5 x 16GA 73 -3.95 6.16 64.2 Pass
T4 260 - 240 Diagonal ROHN 1.5 x 16GA 92 -3.18 6.16 51.7 Pass
T5 240 - 220 Diagonal ROHN 1.5 x 16GA 126 -3.30 6.16 53.6 Pass
T6 220 - 200 Diagonal ROHN 1.5 x 11GA 204 -5.61 12.04 46.6 Pass
T7 200 - 180 Diagonal ROHN 1.5 x 16GA 284 -3.57 6.16 57.9 Pass
T8 180 - 160 Diagonal ROHN 1.5 x 16GA 318 -3.12 6.16 50.7 Pass
T9 160 - 140 Diagonal ROHN 1.5 x 11GA 329 -3.73 11.83 31.6 Pass
T10 140 - 120 Diagonal ROHN 1.5 x 16GA 431 -3.64 6.24 58.3 Pass
T11 120 - 100 Diagonal ROHN 1.5 x 16GA 444 -3.44 6.24 55.2 Pass
T12 100 - 80 Diagonal ROHN 1.5 x 16GA 480 -3.65 6.24 58.6 Pass
T13 80 - 60 Diagonal ROHN 1.5 x 16GA 574 -3.38 6.24 54.1 Pass
T14 60 - 40 Diagonal ROHN 1.5 x 16GA 610 -4.70 6.24 75.3 Pass
T15 40 - 20 Diagonal ROHN 1.5 x 16GA 624 -4.19 6.24 67.2 Pass
T16 20 - 4.81771 Diagonal ROHN 1.5 x 16GA 657 -4.75 6.24 76.2 Pass
T17 4.81771 - 0 Horizontal L4x4x1/4 680 -1.05 72.39 13.8 Pass
T1 300 - 287.341 Top Girt ROHN 1.5 x 16GA 5 -0.34 7.33 4.6 Pass
T2 287.341 - 280 Top Girt L2x2x1/4 27 -1.60 25.14 6.4 Pass
T4 260 - 240 Top Girt ROHN 1.5 x 16GA 85 -0.87 7.33 11.8 Pass
T5 240 - 220 Top Girt ROHN 1.5 x 16GA 120 -1.00 7.33 13.6 Pass
T6 220 - 200 Top Girt ROHN 1.5 x 16GA 175 -1.40 7.48 18.8 Pass
T7 200 - 180 Top Girt ROHN 1.5 x 16GA 234 -1.03 7.33 14.1 Pass
T8 180 - 160 Top Girt ROHN 1.5 x 16GA 291 -1.26 7.33 17.2 Pass
T9 160 - 140 Top Girt ROHN 1.5 x 16GA 322 -1.02 7.40 13.8 Pass
T10 140 - 120 Top Girt ROHN 1.5 x 16GA 379 -1.02 7.40 13.8 Pass
T11 120 - 100 Top Girt ROHN 1.5 x 16GA 437 -0.93 7.40 12.6 Pass
T12 100 - 80 Top Girt ROHN 1.5 x 16GA 469 -1.04 7.40 14.1 Pass
T13 80 - 60 Top Girt ROHN 1.5 x 16GA 526 -1.05 7.40 14.2 Pass
T14 60 - 40 Top Girt ROHN 1.5 x 16GA 583 -1.72 7.40 23.2 Pass
T15 40 - 20 Top Girt ROHN 1.5 x 16GA 616 -1.29 7.40 17.4 Pass
T16 20 - 4.81771 Top Girt ROHN 1.5 x 16GA 650 -1.37 7.40 18.4 Pass
T17 4.81771 - 0 Top Girt L4x4x1/4 678 11.16 74.48 15.0 Pass
T2 287.341 - 280 Bottom Girt L2x2x1/4 29 2.60 28.81 9.0 Pass
ttnnxxTToowweerr Job
Adams Ranch (237546)
Page
35 of 35
Tower Engineering
Professionals
326 Tryon Road
Project
TEP No. 152906.551427
Date
12:25:50 06/15/21
Raleigh, NC 27603
Phone: (919) 661-6351
FAX: (919) 661-6350
Client
Verizon Wireless Designed by
JRM
Section
No.
Elevation
ft
Component
Type
Size Critical
Element
P
K
øPallow
K
%
Capacity
Pass
Fail
T3 280 - 260 Bottom Girt ROHN 1.5 x 16GA 55 -0.87 7.33 11.9 Pass
T4 260 - 240 Bottom Girt ROHN 1.5 x 16GA 89 -1.32 7.33 18.0 Pass
T5 240 - 220 Bottom Girt ROHN 1.5 x 16GA 123 -1.00 7.33 13.6 Pass
T6 220 - 200 Bottom Girt L2 1/2x2 1/2x1/4 178 -1.40 32.15 4.4 Pass
T7 200 - 180 Bottom Girt ROHN 1.5 x 16GA 237 -1.03 7.33 14.1 Pass
T8 180 - 160 Bottom Girt ROHN 1.5 x 16GA 292 -1.31 7.33 17.8 Pass
T9 160 - 140 Bottom Girt ROHN 1.5 x 16GA 325 -1.02 7.40 13.8 Pass
T10 140 - 120 Bottom Girt ROHN 1.5 x 16GA 382 -1.02 7.40 13.8 Pass
T11 120 - 100 Bottom Girt ROHN 1.5 x 16GA 441 -1.22 7.40 16.5 Pass
T12 100 - 80 Bottom Girt ROHN 1.5 x 16GA 472 -1.04 7.40 14.1 Pass
T13 80 - 60 Bottom Girt ROHN 1.5 x 16GA 529 -1.05 7.40 14.2 Pass
T14 60 - 40 Bottom Girt ROHN 1.5 x 16GA 586 -1.28 7.40 17.3 Pass
T15 40 - 20 Bottom Girt ROHN 1.5 x 16GA 619 -1.29 7.40 17.4 Pass
T16 20 - 4.81771 Bottom Girt ROHN 1.5 x 16GA 654 1.68 10.43 16.2 Pass
T3 280 - 260 Guy A@279.385 3/4 690 35.33 36.73 96.2 Pass
T6 220 - 200 Guy A@209.75 9/16 700 16.16 22.05 73.3 Pass
T10 140 - 120 Guy A@139.385 9/16 708 18.67 22.05 84.7 Pass
T13 80 - 60 Guy A@79.3854 9/16 714 17.38 22.05 78.8 Pass
T3 280 - 260 Guy B@279.385 3/4 689 35.71 36.73 97.2 Pass
T6 220 - 200 Guy B@209.75 9/16 696 16.98 22.05 77.0 Pass
T10 140 - 120 Guy B@139.385 9/16 707 18.76 22.05 85.1 Pass
T13 80 - 60 Guy B@79.3854 9/16 713 17.41 22.05 79.0 Pass
T3 280 - 260 Guy C@279.385 3/4 688 35.59 36.73 96.9 Pass
T6 220 - 200 Guy C@209.75 9/16 691 16.93 22.05 76.8 Pass
T10 140 - 120 Guy C@139.385 9/16 703 18.33 22.05 83.1 Pass
T13 80 - 60 Guy C@79.3854 9/16 709 17.14 22.05 77.7 Pass
T3 280 - 260 Top Guy
Pull-Off@279.385
L2x2x1/4 54 13.32 25.71 51.8 Pass
T10 140 - 120 Top Guy
Pull-Off@139.385
4.5x3/8 706 7.60 57.41 13.2 Pass
T13 80 - 60 Top Guy
Pull-Off@79.3854
4.5x3/8 712 8.26 57.41 14.4 Pass
T6 220 - 200 Torque Arm
Top@209.75
C12x20.7 701 -4.88 181.27 55.2 Pass
Summary
Leg (T11) 88.0 Pass
Diagonal
(T16)
76.2 Pass
Horizontal
(T17)
13.8 Pass
Top Girt
(T14)
23.2 Pass
Bottom Girt
(T4)
18.0 Pass
Guy A (T3) 96.2 Pass
Guy B (T3) 97.2 Pass
Guy C (T3) 96.9 Pass
Top Guy
Pull-Off
(T3)
51.8 Pass
Torque Arm
Top (T6)
55.2 Pass
Bolt Checks 75.3 Pass
RATING = 97.2 Pass
Notes:
1) See additional documentation in “Appendix B - Additional Calculations” for calculations supporting the % capacity listed.
2) Rating per TIA-222-H, Section 15.5
Program Version 8.1.1.0 - 6/3/2021 File:G:/Shared drives/152800 - 153499/152906/P-242151_L-551427_237546_ADAMS RANCH_Tower - Structural Design
Drawings/TNX/Mod Run/237546 - Adams Ranch.eri
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 9
tnxTower report - version 8.1.1.0
APPENDIX B
ADDITIONAL CALCULATIONS
ASCE 7 Hazards Report
Address:
No Address at This
Location
Standard:ASCE/SEI 7-16
Risk Category:II
Soil Class:D - Default (see
Section 11.4.3)
Elevation:20.47 ft (NAVD 88)
Latitude:
Longitude:
27.440775
-80.547586
Wind
Results:
Wind Speed: 152 Vmph
10-year MRI 86 Vmph
25-year MRI 104 Vmph
50-year MRI 116 Vmph
100-year MRI 127 Vmph
Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2
Date Accessed: Tue Apr 13 2021
Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear
interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds
correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability =
0.00143, MRI = 700 years).
Site is in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Glazed openings shall be protected
against wind-borne debris as specified in Section 26.12.3.
Page 1 of 3https://asce7hazardtool.online/Tue Apr 13 2021
153mph per ASCE7-10
SS : 0.051
S1 : 0.028
F a : 1.6
F v : 2.4
SMS : 0.082
SM1 : 0.067
SDS : 0.055
SD1 : 0.045
T L : 8
PGA : 0.024
PGA M : 0.039
F PGA : 1.6
Ie : 1
C v : 0.7
Design Response Spectrum
S (g) vs T(s)a
MCE Response SpectrumR
S (g) vs T(s)a
Design Vertical Response Spectrum
S (g) vs T(s)a
MCE Vertical Response SpectrumR
S (g) vs T(s)a
Seismic
Site Soil Class:
Results:
Seismic Design Category
D - Default (see Section 11.4.3)
A
Data Accessed:
Date Source:
Tue Apr 13 2021
USGS Seismic Design Maps based on ASCE/SEI 7-16 and ASCE/SEI 7-16
Table 1.5-2. Additional data for site-specific ground motion procedures in
accordance with ASCE/SEI 7-16 Ch. 21 are available from USGS.
Page 2 of 3https://asce7hazardtool.online/Tue Apr 13 2021
Ice
Results:
Data Source:
Date Accessed:
Ice Thickness: 0.00 in.
Concurrent Temperature: 25 F
Gust Speed: 30 mph
Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8
Tue Apr 13 2021
Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys
and gorges may exceed the mapped values.
Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds,
for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain.
Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice
thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may
exceed the mapped values.
The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of
any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers;
or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from
reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability,
currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement,
affiliation, relationship, or sponsorship of such third-party content by or from ASCE.
ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent
professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such
professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard.
In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors,
employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential
damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by
law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data
provided by the ASCE 7 Hazard Tool.
Page 3 of 3https://asce7hazardtool.online/Tue Apr 13 2021
Project Name:Engineer:
Project Number:Check:
Client Site Number: Date:
CODE:TIA-H
Pipe Leg + Half Sleeve R/F
ΦcL =0.90 - LRFD strength reduction factor (leg, compression)Mast St.:1.00
ΦtL =0.90 - LRFD strength reduction factor (leg, tension)
ΦcS =0.90 - LRFD strength reduction factor (sleeve, compression)
ΦtS =0.90 - LRFD strength reduction factor (sleeve, tension)
Φw =0.75 - LRFD strength reduction factor (weld shear)
Φv =0.75 - LRFD strength reduction factor (shear)
Input - Loads Quick Check
Pinitial:12.7 kips - force from initial load (no wind)Weld Size: OK
Pwind:81.1 kips - force due to final loading including reinforcement Weld Connection:52.1%
Tu:36.7 kips - maximum load on leg Crushing Check:76.5%
Leg Comp. Check:51.0%
Input - Tower Leg 2.5 XS Sleeve Check:56.7%
Built-up Check:77.4%
K:1.00 - effective length factor for leg Leg Tension Check:34.4%
Lu:2.41 ft - unbraced length of tower leg *Rating per TIA-222-H Section 15.5
Fy_leg: 50.00
ksi - minimum specified yield strength of tower leg
Fu_leg: 65.00
ksi - minimum specified ultimate strength of tower leg
r: 0.92
in - minimum radius of gyration of tower leg
Aleg:2.25in2 - area of tower leg
Di: 2.32
in - inside diameter of tower leg
tleg: 0.276
in - thickness of tower leg
Input - Sleeve R/F 3 XS
Fy_sleeve: 35.00
ksi - minimum specified yield strength of sleeve r/f
Fu_sleeve: 60.00
ksi - minimum specified ultimate strength of sleeve r/f
rx_sleeve:0.50in - minimum radius of gyration of sleeve r/f about the x-axis
ry_sleeve:1.14in - minimum radius of gyration of sleeve r/f about the y-axis
Asleeve:1.51in2 - area of sleeve r/f
tsleeve:0.30in - thickness of sleeve r/f
Termination: Connected to Leg ONLY
Input - Sleeve Connection to Leg
a: 12.00
in - spacing of connectors connecting the sleeve to the leg
D: 3.00
- weld size for the weld connecting the sleeve to the leg (unit = # of 16ths)
Length //: 6.00
in - length of weld on each side of the leg at the termination
Length :0.00in - length of weld at the bottom/top of the leg sleeve at termination (D/2)
No: 2.00
- number of longitudinal welds per end of the leg (typically near side & far side, so 2)
FEXX: 70.00
ksi - weld electrode classification
Width: 3.50
in - maximum width of the built-up leg
Gap:7.00in - length of leg considered for crushing
Input - Built-up Leg Section 2.5 XS w/3 XS Half Sleeve
rx_bu:0.92in - minimum radius of gyration of the built-up section about the x-axis
ry_bu:1.01in - minimum radius of gyration of the built-up section about the y-axis
Input - Grouted Leg
Ec: 0 ksi - Modulus of Elasticity of Grout
E_leg: 29,000 ksi - Modulus of Elasticity of Leg
E_sleeve: 29,000 ksi - Modulus of Elasticity of Sleeve
Elevation:200ft - 220ft
- from tnxTower
Adams Ranch JRM
TEP No. 152906.551427 RAL
237546 6/15/2021
G:\Shared drives\152800 ‐ 153499\152906\P‐242151_L‐551427_237546_ADAMS RANCH_Tower ‐ Structural Design Drawings\Additional Calculations\05_Built‐Up Leg Calculations_Added Eccentric Checks 200‐220
Project Name:Engineer:
Project Number:Check:
Client Site Number: Date:
CODE:TIA-H
Pipe Leg + Half Sleeve R/F
ΦcL =0.90 - LRFD strength reduction factor (leg, compression)Mast St.:1.00
ΦtL =0.90 - LRFD strength reduction factor (leg, tension)
ΦcS =0.90 - LRFD strength reduction factor (sleeve, compression)
ΦtS =0.90 - LRFD strength reduction factor (sleeve, tension)
Φw =0.75 - LRFD strength reduction factor (weld shear)
Φv =0.75 - LRFD strength reduction factor (shear)
Input - Loads Quick Check
Pinitial: 13.1
kips - force from initial load (no wind)
Pwind:57.1 kips - force due to final loading including reinforcement Weld Connection:46.1%
Tu:0.00 kips - maximum load on leg Crushing Check:49.9%
Leg Comp. Check:50.9%
Input - Tower Leg 2 XS Sleeve Check:46.0%
Built-up Check:64.3%
K:1.00 - effective length factor for leg Slenderness Check: OK
Lu:2.41 ft - unbraced length of tower leg Leg Tension Check:0.0%
Fy_leg:50.00 ksi - minimum specified yield strength of tower leg *Rating per TIA-222-H Section 15.5
Fu_leg: 65.00
ksi - minimum specified ultimate strength of tower leg
r: 0.77
in - minimum radius of gyration of tower leg
Aleg:1.48in2 - area of tower leg
Di: 1.94
in - inside diameter of tower leg
tleg:0.22in - thickness of tower leg
f`c:0.00ksi - minimum specified compressive strength of grout (If ungrouted enter 0)
Input - Sleeve R/F 3 XS
Fy_sleeve: 35.00
ksi - minimum specified yield strength of sleeve r/f
Fu_sleeve: 60.00
ksi - minimum specified ultimate strength of sleeve r/f
rx_sleeve:0.50in - minimum radius of gyration of sleeve r/f about the x-axis
ry_sleeve:1.14in - minimum radius of gyration of sleeve r/f about the y-axis
Asleeve:1.51in2 - area of sleeve r/f
tsleeve:0.30in - thickness of sleeve r/f
Termination: Connected to Flange
Input - Sleeve Connection to Leg
a: 12.00
in - spacing of connectors connecting the sleeve to the leg
D: 4.00
- weld size for the weld connecting the sleeve to the leg (unit = # of 16ths)
Length //: 0.00
in - length of weld on each side of the leg at the termination
Length :5.50in - length of weld at the bottom/top of the leg sleeve at termination (D/2)
No: 2.00
- number of longitudinal welds per end of the leg (typically near side & far side, so 2)
FEXX: 70.00
ksi - weld electrode classification
Width: 3.50
in - maximum width of the built-up leg
Gap:0.00in - length of leg considered for crushing
Input - Built-up Leg Section 2 XS w/3 XS Half Sleeve
rx_bu:0.75in - minimum radius of gyration of the built-up section about the x-axis
ry_bu:0.97in - minimum radius of gyration of the built-up section about the y-axis
Input - Grouted Leg
Ec: 0 ksi - Modulus of Elasticity of Grout
E_leg: 29,000 ksi - Modulus of Elasticity of Leg
E_sleeve: 29,000 ksi - Modulus of Elasticity of Sleeve
Elevation:180ft - 200ft
- from tnxTower
Adams Ranch JRM
TEP No. 152906.551427 RAL
237546 6/15/2021
G:\Shared drives\152800 ‐ 153499\152906\P‐242151_L‐551427_237546_ADAMS RANCH_Tower ‐ Structural Design Drawings\Additional Calculations\06_Built‐Up Leg Calculations_Added Eccentric Checks 180‐200
Tower Type:
146 kips Capacity Demand Rating* Check
3 kips 20.59 0.00 0.0% Pass
9.99 3.00 28.6% Pass
14.16 5.81 39.1% Pass
0 ft-kips 233.69 15.00 6.4% Pass
300 ft 202.09 9.00 4.2% Pass
ft 558.49 0.00 0.0% Pass
0 in 1499.67 147.70 9.4% Pass
0 in 267.86 44.38 15.8% Pass
107.77 2.77 2.4% Pass
0.164 0.013 7.7% Pass
Circular 535.72 5.40 1.0% Pass
2ft 0.164 0.000 0.0% Pass
0.5 ft 535.72 0.00 0.0% Pass
6
8
4 Structural Rating*:15.8%
3 Soil Rating*:39.1%
Tie
3in
4.5 ft
5.5 ft
2ft
6
7
3in
60 ksi
3ksi
150 pcf
125 pcf
23.600 ksf <--Toggle between Gross and Net
0.000 ksf
30 degrees
0
0
0.00 ft
No
4ft
Uplift, Puplift:
Base Shear, Vu_comp:
Groundwater Depth, gw:
Rebar Grade, Fy:
Dry Concrete Density, δc:
Depth, D:
Pad Width, W1:
Pad Thickness, T:
Pad Clear Cover, ccpad:
Material Properties
Soil Properties
Friction Angle, ϕ:
Moment, Mu:
Flexural 2-way (Tension) (kip*ft)
Pad Shear - 2-way (Uplift) (ksi)
Pier Properties
BP Dist. Above Fdn, bpdist:
Bolt Circle / Bearing Plate Width, BC:
Flexural 2-way (Comp) (kip*ft)
Block Foundation?:
Pad Shear - 2-way (Comp) (ksi)
Pier Flexure (Tension) (kip*ft)
Overturning (kip*ft)
Pad Flexure (kip*ft)
Pad Shear - 1-way (kips)
Pier Compression (kip)
Rectangular Pad?:
Pier and Pad Foundation
Site Number:
Site Name:
Compression, Pcomp:
TIA-222 Revision:
TEP Number:
Superstructure Analysis Reactions
H
Guyed
237546
Adams Ranch
152906.551427
Pier Flexure (Comp.) (kip*ft)
Lateral (Sliding) (kips)
Bearing Pressure (ksf)
Uplift (kips)
Foundation Analysis Checks
Neglected Depth, N:
Uplift Shear, Vu_uplift:
Pier Shape:
Tower Height, H:
Base Face Width, BW:
Cohesion, Cu:
Ultimate Gross Bearing, Qult:
Pad Rebar Quantity (Bottom dir. 2), mp2:
Pad Rebar Size (Bottom dir. 2), Sp2:
Total Soil Unit Weight, γ:
Top & Bot. Pad Rein. Different?:
*Rating per TIA-222-H Section
15.5
Foundation Bearing on Rock?
SPT Blow Count, Nblows:
Base Friction, μ:
Pier Diameter, dpier:
Ext. Above Grade, E:
Pier Rebar Size, Sc:
Pier Rebar Quantity, mc:
Concrete Compressive Strength, F'c:
Pier Tie/Spiral Quantity, mt:
Pier Reinforcement Type:
Pier Clear Cover, ccpier:
Pad Properties
Pier Tie/Spiral Size, St:
Version 4.1.0
TIA-222 Revision:55.00 kips38.00 kipsResultant Force, Rf:66.85kips106.89 55.0049.0% Pass300.00 ft90.93 38.0039.8% Pass206.00 ft2142.21 137.506.1% Pass34.6deg2148.24 95.004.2% Pass129.84 66.8549.0% Pass*Rating per TIA-222-H Section 15.58ft49.0%6ft6.1%5ft49.0%20 ft22.2yd30ft0ft1.5 ft8Warning: Maximum soil depth is not equal to bottom of deadman.11Soil Properties:No. of Soil Layers:38Layerφ, degcu, ksfδ, pcf depth, ft Ultimate fs (ksf) N (blows/ft)9 1 32 0.000 125 1.500.0004 2 32 0.000 62.6 3.000.000Anchor Shaft Diameter, ds:1.4375 in 3 32 0.000 62.6 8.000.00024in251678960 ksi4 ksi *key: φ = Internal Angle of Friction0.088kcfcu = Cohesion / Undrained Shear Strength3inδ = Buoyant Soil Unit Weight50 ksid = Depth to Bottom of Layer65 ksiUltimate fs = Geotechnical Report-provided skin friction / adhesionN = SPT Blow CountAnchor Shaft Area Override:Shear Lag Factor, u:No. of Bars in Front of Block:Groundwater Level, gw:Stirrup Size:Anchor Shaft Quantity. n:Guyed Anchor Top Rebar Size, Sat:No. of Bars in Top of Block:Guyed Anchor Front Rebar Size, Saf:Uplift Capacity (kips):Neglect Depth, Neg:Anchor Shaft Ultimate Strength, Fu':Section Type (Reference Only):Material PropertiesRebar Grade, Fy:Concrete Strength, F'c:Wt. Avg.Concrete Density, δx:Anchor Shaft Grade, Fy':Clear Cover, cc:Checks capacity of anchor blocks for a guyed tower.Concrete Volume, Vc:Design ReactionsToe Width, toe:Anchor Thickness, Ta:Shear, S:Resultant Angle to Horizontal, θ: Guy Anchor Radius, R:Tower Height, H:Guy Anchor PropertiesHDepth to Bottom of Deadman, Da:Anchor Width, Wa:Anchor Length, La:Guyed Anchor Block FoundationSite Number:Site Name:Design ChecksRating* CheckCapacity Demand237546Adams RanchTEP Number:Location:Uplift, Ua:152906.551427INNERLateral Capacity (kips):Lateral Flexural Capacity (ft*kips):Uplift Flexural Capacity (ft*kips):Anchor Shaft (kips):Anchor Shaft Rating: Structural Rating: Soil Rating: Version 4.0.0
TIA-222 Revision:24.00 kips26.00 kipsResultant Force, Rf:35.38kips48.10 24.0047.5% Pass300.00 ft61.48 26.0040.3% Pass240.00 ft637.23 45.006.7% Pass47.3deg342.83 48.7513.5% Pass98.17 35.3834.3% Pass*Rating per TIA-222-H Section 15.57ft34.3%5.3 ft13.5%3ft47.5%15 ft8.8yd30ft0ft1.5 ft7Warning: Maximum soil depth is not equal to bottom of deadman.4Soil Properties:No. of Soil Layers:37Layerφ, degcu, ksfδ, pcf depth, ft Ultimate fs (ksf) N (blows/ft)4 1 32 0.000 125 1.500.0003 2 32 0.000 62.6 4.000.000Anchor Shaft Diameter, ds:1.25 in 3 32 0.000 62.6 7.000.00024in251678960 ksi3 ksi *key: φ = Internal Angle of Friction0.088kcfcu = Cohesion / Undrained Shear Strength3inδ = Buoyant Soil Unit Weight50 ksid = Depth to Bottom of Layer65 ksiUltimate fs = Geotechnical Report-provided skin friction / adhesionN = SPT Blow CountAnchor Shaft Area Override:Shear Lag Factor, u:No. of Bars in Front of Block:Groundwater Level, gw:Stirrup Size:Anchor Shaft Quantity. n:Guyed Anchor Top Rebar Size, Sat:No. of Bars in Top of Block:Guyed Anchor Front Rebar Size, Saf:Uplift Capacity (kips):Neglect Depth, Neg:Anchor Shaft Ultimate Strength, Fu':Section Type (Reference Only):Material PropertiesRebar Grade, Fy:Concrete Strength, F'c:Wt. Avg.Concrete Density, δx:Anchor Shaft Grade, Fy':Clear Cover, cc:Checks capacity of anchor blocks for a guyed tower.Concrete Volume, Vc:Design ReactionsToe Width, toe:Anchor Thickness, Ta:Shear, S:Resultant Angle to Horizontal, θ: Guy Anchor Radius, R:Tower Height, H:Guy Anchor PropertiesHDepth to Bottom of Deadman, Da:Anchor Width, Wa:Anchor Length, La:Guyed Anchor Block FoundationSite Number:Site Name:Design ChecksRating* CheckCapacity Demand237546Adams RanchTEP Number:Location:Uplift, Ua:152906.551427OUTERLateral Capacity (kips):Lateral Flexural Capacity (ft*kips):Uplift Flexural Capacity (ft*kips):Anchor Shaft (kips):Anchor Shaft Rating: Structural Rating: Soil Rating: Version 4.0.0
June 15, 2021
300-ft Guyed Tower Structural Modification Analysis Report 237546 - Adams Ranch
TEP Project Number 152906.551427 Page 10
tnxTower report - version 8.1.1.0
APPENDIX C
STRUCTURAL DESIGN DRAWINGS
PROJECT TEAMPROJECT CONTACT:SITE NAME:ADAMS RANCHSITE NUMBER:STRUCTURAL DESIGN DRAWINGS21715 ORANGE AVENUEFORT PIERCE, FL 34945(ST. LUCIE COUNTY)N 27°26'26.79", W 80°32'51.31"SITE ADDRESS:237546ENGINEERING FIRM PROJECT MANAGER:MODIFICATION PROVISIONS006-15-21MODIFICATION DRAWINGSJoRMJRMTITLE SHEETNO.SHEET TITLEINDEX OF SHEETSREVT-10152906.551427ATTENTIONJune 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.netFL COA # 31011
XNANAXNAXXNANANAXNAXNAXNAXNAXXNAMI CHECKLISTPRE-CONSTRUCTIONCONSTRUCTIONPOST-CONSTRUCTIONXXXGENERALMODIFICATION INSPECTION NOTES:SERVICE LEVEL COMMITMENT····REQUIRED PHOTOS···················NANANA006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMN-1MI CHECKLISTAND NOTES
ATTENTIONGENERAL NOTES:WELDING NOTES:STRUCTURAL STEEL NOTES:N-2PROJECT NOTES I006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRM
LEGWORKABLE GAGES221213433124NOMINAL HOLE DIMENSIONSSHORT SLOTSTANDARDHOLEBOLTDIAMETERALLOWABLE ANGLE COPEBOLT THREADSBOLTDIAMETERTHREADLENGTHBOLT DETAILSSINGLE SHEAR CONNECTIONS:DOUBLE SHEAR CONNECTIONS:BOLT EDGE AND SPACINGSPACINGMIN. EDGEBOLTDIAMETERNOTE:SECTION AT CENTER ANDSTITCH CONNECTIONBOLT LENGTHS OVER FOUR DIA. BUT NOT EXCEEDING EIGHT DIA.BOLT LENGTHS UP TO AND INCLUDING FOUR DIA.8.2.1 TURN-OF-THE-NUT TIGHTENINGBOLT TIGHTENING PROCEDURE:N-3PROJECT NOTES II006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRM
GUY PATHGUY ANCHOR RADIUSGUY ANCHOR RADIIINNEROUTERNO.MODIFICATION DESCRIPTIONELEVATION(FT.)SHEETMODIFICATION SCHEDULENOTES:006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMS-1TOWER ELEVATIONAND MODIFICATIONSCHEDULETOWER ELEVATION
BRACING PARTS SCHEDULEPROPOSED BRACE(A572-50)QTYPROPOSEDBOTTOMSECTIONTOPELEVATION(FT.)PANEL #SIZE x LENGTHLENGTHBRACE BOLT(A325X)BOLT-ON LUGASSEMBLYQTYLUG PART #NOTES:ATTENTIONPANEL #87654321MEMBERQTYS-2SECTION ELEVATIONBRACINGREPLACEMENTDETAILS I006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMALLOWABLE COPE DETAIL
FABRICATION DIMENSIONSPIECEMARKEXISTING LEGDIMENSION"A"DIMENSION"B"DIMENSION"C"DIMENSION"D"DIMENSION"E"U-BOLTTORQUEFRONT VIEWSIDE VIEWTOP VIEWNOTES:LUG INVERTEDLUG UPRIGHT006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMS-3BRACINGREPLACEMENTDETAILS IIBOLT ON LUG - DETAILSBOLT ON LUG - ISOMETRICTYPICAL LUG INSTALLATION DETAIL
GIRT REPLACEMENT SCHEDULEGIRT BRACE (ASTM A572-50)QTYPROPOSEDBOTTOMSEC.TOPELEVATION (FT.)AVERAGE LENGTHBRACE BOLT (A325-X)SIZE x LENGTHQUANTITYFACEPLAN VIEWABC006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMALLOWABLE COPE DETAILBRACINGREPLACEMENTDETAILS IIIS-4DAMAGED TOP GIRT BRACE AT 300' ON BC FACEDAMAGED BOTTOM GIRT BRACE AT 260' ON AB FACETYPICAL SECTION ELEVATIONS
SCREW PIN MOUSING DETAILTAG TEXT CHART"A"TAGQTY.TENSION TAG NOTES:ELEV.(FT.)"B""C"GUY HARDWAREGUY HARDWARE NOTESSIDE VIEWTOP VIEWGUY WIRE SPLICE DETAILTURNBUCKLESIZEQTY.EXTRA HEAVY THIMBLESIZEQTY.BIG GRIPSIZEQTY.END SLEEVESIZEQTY.WIRE PROPERTIESSIZE# WIRES INSTRANDMIN. B.S.(KIPS)SHACKLESIZECROSBYPART #QTY.CROSBYPART #CROSBYPART #PLP PART #GUY WIREDETAILS I006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMS-5
INSTALL GUYS & PLUMB TOWER:GUY WIRE PROPERTIESGUY TENSIONING INFORMATIONGUY WIREDETAILS II006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMS-6
ATTENTIONNOTES:AAACCCBBB006-15-21MODIFICATION DRAWINGSADAMS RANCH(237546)June 15, 2021TOWER ENGINEERING PROFESSIONALS326 TRYON ROADRALEIGH, NC 27603OFFICE: (919) 661-6351www.tepgroup.net0152906.551427FL COA # 31011JoRMJRMGUY ANCHORGROUNDING DETAILSGUY ANCHOR PLAN VIEWS-7