HomeMy WebLinkAboutjb_349367_00_c_acad_b_01 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES
A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED
BUILDING CONC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER.
EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTING
EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN
FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3.
ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING
DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION,
MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE
KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17.
BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE
NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY
PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5.
PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY
STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B).
TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING
VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR
AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC
DISCONNECTING MEANS PER ART. 690.31(E).
7. ALL WIRES SHALL BE PROVIDED WITH STRAIN
RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY
UL LISTING.
8. MODULE FRAMES SHALL BE GROUNDED AT THE UL
— LISTED LOCATION PROVIDED BY THE
MANUFACTURER USING UL LISTED GROUNDING
HARDWARE.
9. MODULE FRAMES, RAIL, AND POSTS SHALL BE
BONDED WITH EQUIPMENT GROUND CONDUCTORS.
VICINITY MAP INDEX
Sheet 1 COVER SHEET
Sheet 2 SITE PLAN
Sheet 3 STRUCTURAL VIEWS
Sheet 4 UPLIFT CALCULATIONS
LICENSE GENERAL NOTES j Sheet 5 THREE LINE DIAGRAM
Sheet 6 THREE LINE DIAGRAM CONT.
1. ALL WORK SHALL COMPLY WITH THE 2020 Cutsheets Attached
FLORIDA BUILDING CODE (7TH EDITION), FLORIDA FIRE
PREVENTION CODE (7TH EDITION).
2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE ;
2017 NATIONAL ELECTRIC CODE.
i
MODULE GROUNDING METHOD: ZEP SOLAR
AHJ: St. Lucie County
REV BY DATE COMMENTS
9 REV A JF 1 7/7/2021 Decreased the system size and powerwall count.
' REV B JC 10/14/21 Changed modules to 425W
UTILITY: Florida Power and Light REV c JC 11/4/21 Adjusted PW tie-in and quantity and added blocking
J B-3 4 9 3 6 7 O O CUSTOMER: DESCRIPTION: DESIGN:
CONTAINED AL A THE INFORMATION HEREIN JOB NUMBER: Mario De Ol i ve i r Jessl yn Cobero T = 5 L n
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 7924 Saddlebrook Dr C 27 KWH ENERGY STORAGE YSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie, FL 34986
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (27) Tesla # T425S
TESLA EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. WV 9045635873 1 C 11 4 2021
Powewerwall+ Tesla Inc 240V 1850000-00—A 7.6 kW 13.5 k h COVER SHEET
PITCH: 231 (5:12) ARRAY PITCH:231 (5:12)
MP1 AZIMUTH: 146 ARRAY AZIMUTH: 146
MATERIAL: Low Profile W-Tile STORY: 2 Stories
PITCH: 23 ARRAY PITCH:23
6 MP2 AZIMUTH:236 ARRAY AZIMUTH: 236
e)DRIVEWAY °o MATERIAL: Low Profile W-Tile STORY: 2 Stories
PITCH: 23 ARRAY PITCH:23
MP3 AZIMUTH:326 ARRAY AZIMUTH: 326
MATERIAL: Low Profile W-Tile STORY: 2 Stories
Digitally signed by
ds
Jim ChildsDate:2l2
Date:2021.11.04
17:37:44-07'00'
LEGEND
0 (E) UTILITY METER & WARNING LABEL
Inv INVERTER W/ INTEGRATED DC DISCO
& WARNING LABELS
DRELAY AUTOMATIC RELAY
DC
DC DISCONNECT & WARNING LABELS
< AC
���c"� AC DISCONNECT & WARNING LABELS
Front Of House O DC JUNCTION/COMBINER BOX & LABELS
0 Ess ENERGY STORAGE SYSTEM FOR STAND
ALONE OPERATION
OD DISTRIBUTION PANEL & LABELS
Lc LOAD CENTER & WARNING LABELS
ODEDICATED PV SYSTEM METER
I �Ts� RSD RAPID SHUTDOWN
�I STANDOFF LOCATIONS
_2 CONDUIT RUN ON EXTERIOR
I _ _ CONDUIT RUN ON INTERIOR
I rQ� GATE/FENCE
r�, HEAT PRODUCING VENTS ARE RED
�\ N J INTERIOR EQUIPMENT IS DASHED
SITE PLAN N
Sv Scale:1/16" = 1' W E
01, 16' 32'
—in mom S
J B-3 4 9 3 6 7 O O CUSTOMER: DESCRIPTION: DESIGN:
CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: Mario De Oliveir 11.475 KW PV ARRAY Jesslyn Cabero T = S L n
CONTTAINEDAINED SHAA LL NOT BE USED FOR THE � �
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 7924 Saddlebrook Dr 27 KWH ENERGY STORAGE SYSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie, FL 34986
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (27) Tesla # T425S
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. POwerwoll+ Tesla Inc [240V1 # 1850000-00—A 7.6 kW 13.5 k h9045635873 SITE PLAN 2 C 11/4/2021
INSTALLATION NOTES:
(N) STANDOFF SHALL LAG DIRECTLY 1. CUT (N) BLOCKING TO FIT TIGHT
INTO (N) BLOCKING BETWEEN (E) TRUSSES AND KEEP FLUSH
TO ROOF SHEATHING. ENSURE THERE ARE
(N) 2x6 DF#2 OR SPF#2 BLOCKING. NO GAPS BETWEEN MEMBERS.
2. INSTALL (N) BLOCKING WITH TWO A34
CLIPS, ONE AT EACH END OF BLOCKING.
3. NAIL A34 CLIPS TO EXISTING RAFTERS
WITH (8) 8D (0.131") X 1.5" NAILS, FILLING
(E) JACK TRUSS OR RAFTER ALL HOLES. ENSURE ALL NAILS ARE
(BLOCKING NOT REQUIRED DOWN HERE) LOCATED AWAY FROM EDGE OF MEMBERS
TO AVOID SPLITTING WOOD.
(N) SIMPSON A34 CLIPS (2 PER BLOCK) * INSTALL BLOCKING ONLY BELOW
W/ (8) 8d (0.131 ') X 1-1/2" NAILS PER CLIP STANDOFF LOCATIONS.
(E) SHORTEST BOX TRUSS (BLOCKING FROM
THIS STRUCTURE WILL HERE UP TO RIDGE AS NEEDED)
S SIDE VIEW OF MP1 NTS A BLOCKING UPGRADE.
RECEIVE
MPl '
TOP CHORD 20 @ 24"OC ROOF AZI 146 PITCH 23 STORIES:2 2
ARRAY AZI 146 PITCH 23
BOTTOM CHORD 2X4 @ 24"OC Low Profile W-Tile
NEW BLOCKING SIDE VIEW
INSTALLATION ORDER
ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER
(6) LOCATION, AND REMOVE TILE.
(1) PLACE STANDOFF BASE & DRILL
----------- ------ ---- PILOT HOLES AT THE RAFTER
LOCATION.
" DIA BOLT & NUT (1) (2) (7) (3) q—CLEAN PAPER AROUND PILOT
HOLE.
ZEP SPANNER
BAR CLAMP (3) ADJUST STANDOFF TO BATTEN
HEIGHT.
STANDOFF
(E) TILE 34" MIN. SEAL PILOT HOLES AND BOTTOM
U ((4) OF STANDOFF WITH POLYURETHANE
(E) ROOF DECKING (5) (4) SEALANT.
5/16" DIA STAINLESS 5) LAG STANDOFF INTO RAFTER.
STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES
(6) NOTCH TILE WEATHERING TO FIT
(E) RAFTER STANDOFF AROUND STANDOFF.
S y Scale: 1 1/2" — 1' 7) REINSTALL TILE.
CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J — 9 6
CONTAINED SHALL NOT Mario De Oliveir 11
USED FOR THE .475 KW PV ARRAY Jesslyn Cabero77
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: T
SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 7924 Saddlebrook Dr 27 KWH ENERGY STORAGE SYSTEM = 5Ln
PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES Port St. Lucie, FL 34986
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (27) Tesla # T425S
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. PoWerWall+ Tesla Inc [240VI # 1850000-00—A 7.6 kW 13.5 �kl-19045635873 STRUCTURAL VIEWS 3 C 11/4/2021
Jobsite Specific Design Criteria
Design Code ASCE 7-16
Risk Category II Table 1.5-1
Ultimate Wind Speed V—Ult 160 Fig. 1609A
Exposure Category C Section 26.7
Ground Snow Load pg 0 Table 7-1
Edge Zone Width a 10.1 ft Fig. 30.3-2A to I
MP Specific Design Information
MP Name MP1
Roofing Low Profile W—Tile
Standoff ZEP Mighty Hook
Pitch 23
SL/RLL: PV 0.0
SL/RLL: Non—PV 19.0
Standoff Spacing and Layout
MP Name MP1
Landscape X—Spacing 24
Landscape 12
X—Cantilever
Landscape Y—Spacing 52
Landscape 24
Y—Cantilever
Portrait X—Spacing 24
Portrait X—Cantilever 12
Portrait Y—Spacing 52
Portrait Y—Cantilever 24
Layout Not Staggered
X and Y are maximums that are always
relative to the structure framing that
supports the PV. X is across rafters and Y
is along rafters.
J B-3 49 3 6 7 O O CUSTOMER: DESCRIPTION: DESIGN:
CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: Mario De Oliveir 11.475 KW PV ARRAY Jesslyn Cabero T 5 L n
CONTTAINEDAINED SHAA LL NOT BE USED FOR THE � �
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 7924 Saddlebrook Dr 27 KWH ENERGY STORAGE SYSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS MODu�Es: Port St. Lucie, FL 34986
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (27) Tesla # T425S
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. Powerwall+ Tesla Inc [240V1 # 1850000-00—A 7.6 kW 13.5 00045635873 UPLIFT CALCULATIONS 4 C 11/4/2021
MAIN PANEL SPECS GENERAL NOTES LICENSE
Panel Number: NoLabel
Meter Number:ACD2620
Underground Service Entrance
E 200A MAIN SERVICE PANEL
E 20OA/2P MAIN CIRCUIT BREAKER LOAD CENTER
$ BACKUP GATEWAY
Z
2P Z
50Af 2P
�` TO NEW
POWERWALL+
I JN — ----- -----
e 30�A/2P 7 L1
:,±Lz X ENERGY
N STORAGE
SH LUGSFEED i I L--—————— EGc SYSTEM
THROUGH LUGS N I I
I
Gc — 6
o -- --
z z
c� W I N
GEC n�
0
TO 120/240V I G n
SINGLE PHASE
I
UTILITY SERVICE I
EGCI N L2 L1
I
I I
I
I
Panel Limit feature for Powerwall unit(s)
to be utilized (E) LOAD
Field label to be at the point of interconnectio : •�
"PCS Controlled Current Setting: 200A '
•
The maximum output current from this system awards •
the main panel is controlled electronically. Refe to
manufacturer's instructions for more information."
(E) 200A
DISTRIBUTION PANEL C
POI (1)Gro rid Rod
L- 3 AWG #2/0, THWN-2, Black
5r8 x 8, Copper IUD
(1)AWG #6, THWN-2, Green AC
(1)Tesla #1232100-00—G L-L(1)Copduit
Z Back—up Gateway 2.0 NA for AC PW 2.0 2 PVC; Schedule 80
—(1)CUTLER—HAMMER #BR230 (1)AWG #10, THWN-2, Black
Breaker; 30A/2P, 2 Spaces O�
�(1)AWG #10, THWN-2, Red
—(1)CUTLER—HAMMER #BR250 ILL
Breaker; 50A/2P, 2 Spaces (1)AWG #10, THWN-2, White
—(1)Panelboard Accessory It for GW 2.0 NA —(1)AWG #10, THWN-2, Green —(1)Conduit Kit; 3/4" EMT
200A, 6sp/12cir, 120/24OV, 1PH (3)AWG #2/0, THWN-2, Black
y (1)Eaton M22—PVT—K01 Emergency Stop Button ®L-L(1)AWG #6, THWN-2, Green
I L(1)Copduit
X (1)3012170-05—B 2 PVC; Schedule 80
ASY,AC POWERWALL2.1,5KW,13.5KWH,M48
W (1)Sgguare D #QBL22200
2ODA Circuit Breaker; Moll) #eD #Case, 2—Pole, 240V, 1OkAIC
—(1)SQUARE D #Q2220ONRB
Enclosure only,200A Max,Accepts Q Series Breakers
J B-3 4 9 3 6 7 O O CUSTOMER: DESCRIPTION: DESIGN:
CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: Mario De Oliveir 11,475 KW PV ARRAY yn T = 5 L n
CONTAINED SHALL NOT BE USED FOR THE Jessl Cabero
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 7924 Saddlebrook Dr 27 KWH ENERGY STORAGE SYSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie, FL 34986
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (27) Tesla # T425S
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. POWerWall+ Teslo Inc [240V1 # 1850000-00—A 7.6 kW 13.5 k h9045635873 THREE LINE DIAGRAM 5 C 11/4/2021
GROUND SPECS MAIN PANEL SPECS GENERAL NOTES PRODUCT SPECS MODULE SPECS LICENSE
Panel Number: Inv 1: DC Ungrounded 1 — (1) Powerwall+ Tesla Inc [240V] #1850000-00—A 7.6 kW/13.5 kWh — (27) Tesla #T425S
Meter Number: PV Module, 425W, 397 PTC, 40MM, Black Frame, MC4/MC4—EVO2, ZEP, 1000V
2
Voc: 48.66 Vpmax: 5 g9
3 IIsc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER
E—STOP Product 1
BUTTON T
1
Y ENERGY STORAGE 5 240V DC- MP 1: 1x7
12v DC+ —
----------————————————— EGC -----------------�
DL
TO MAIN PANEL �z DC+ IF 2 Dc+
AND ENERGY
STORAGE SYSTEM N DC- I 3 DC-
EGC DC+ i I I DC+ MP 1: 2x10
DC- DC- I I I
EGC— —
-----——————————————————————————————— EGC —--——————————----j
(1)Conduit Kit; 3/4" EMT
CONDUIT MATERIAL TYPE TBD IN FIELD TO 2017 NEC
STANDARDS
BACKUP SWITCH WILL BE INSTALLED IN A 2ND METER
SOCKET.
CONDUIT MATERIAL TYPE TBD IN FIELD TO 2017 NEC
STANDARDS
Voc* = MAX VOC AT MIN TEMP GD Please see MCI wiring detail page for more information
A (1)EE-000550-001 MC4 Y—Connector, Receptacle
AC —(1)EE-000550-000 MC4 Y—Connector, Plug DC
PV (3)Tesla MCI, 60OV, 13A
(1)AWG #8, THWN-2, Block —(1)AWG #8, THWN-2, White (2)PV Wire, AWG 10, Block Voc* =518.12 VDC Isc —22.48 ADC (2)PV O Wire, AWG 10, Black Voc* =362.69 VDC Isc =11.24 ADC L-L(1)AWG #8, THWN-2, Red O (1)AWG #10, Solid Bare Copper EGC Vmp =410.5 VDC Imp=20.72 ADC O (1)AWG #10, THHN/THWN-2, Green EGC Vmp =287.35 VDC Imp=10.36 ADC
(1)AWG #10, THWN-2, Green EGC Vmp =240 VAC Imp=32 AAC (1)Conduit Kit; 3/4" EMT (1)Conduit Kit; 3/4" EMT
—(1)Conduit Kit; 3/4" EMT (2)PV Wire, AWG 10, Black Voc* =362.69 VDC Isc =11.24 ADC (4)PV Wire, AWG 10, Black Voc* =518.12 VDC Isc =11.24 ADC
® (1)AWG #10, Solid Bare Copper EGC Vmp =287.35 VDC Imp=10.36 ADC O (1)AWG #10, THHN/THWN-2, Green EGC Vmp =410.5 VDC Imp=10.36 ADC
(1)Conduit Kit; 3/4" EMT (1)Conduit Kit; 3/4" EMT
J B-3 4 9 3 6 7 O O CUSTOMER: DESCRIPTION: DESIGN:
CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: Mario De Oliveir 11,475 KW PV ARRAY yn T = 5 L n
CONTAINED SHALL NOT BE USED FOR THE Jessl Cabero
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 7924 Saddlebrook Dr 27 KWH ENERGY STORAGE SYSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie, FL 34986
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (27) Tesla # T425S
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. POWerWall+ Teslo Inc [240V1 # 1850000-00—A 7.6 kW 13.5 k h9045635873 THREE LINE DIAGRAM CONT. 6 C 11/4/2021
SOLAR PV SYSTEM
EQUIPPED WITH RAPID
SHUTDOWN
TURN RAPID SHUTDOWN SWITCH TO THE "OFF"
POSITION TO SHUT DOWN PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE ARRAY
BATTERY STORAGE USED AT THIS FACILITY
- Address: 7924 Saddlebrook Dr
2X ENERGY
STORAGE
SYSTEM
INVERTER
` y
RAPID
SHUTDOWN
SWITCH
UTILITY
SERVICE
OPERATING VOLTAGE = 240V JB-349367-00
J B-3 49 3 6 7 0 0 CUSTOMER: DESCRIPTION: DESIGN:
CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: Mario De Oliveir 11.475 KW PV ARRAY Jesslyn Cabero T 5 L n
CONTTAINEDAINED SHALL NOT BE USED FOR THE � �
BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM:
SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 7924 Saddlebrook Dr 27 KWH ENERGY STORAGE SYSTEM
PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: Port St. Lucie, FL 34986
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE (27) Tesla # T425S
TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE:
PERMISSION OF TESLA INC. PowerWall+ Tesla Inc [240V1 # 1850000-00—A 7.6 kW 13.5 k h9045635873 SITE PLAN PLACARD 7 C 11/4/2021
WARNING:PHOTOVOLTAIC POWER SOURCE Label Location:
- ' WARNING Label • 'Location: WARNING Label Location:
I '
Code:Per Code:
NEC ELECTRIC SHOCK HAZARD • ELECTRIC SHOCK HAZARD
690.31.G.3 NEC 'DO NOT TOUCH TERMINALS 1 13
THE DC CONDUCTORS OF THIS
LabelTERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE
PHOTOVOLTAIC DC LOADN TH OPEN POS TIONIZED MAY BEOENERG ZED
DISCONNECT Per
NEC .•1
.113.13
Label Location: SOLAR . ..-
1 Location:
Label Location: WARNING EQUIPPED ..- . . .- and,Telsa Inverter
MAXIMUM POWER _A Code: INVERTER OUTPUT ••e: Per "
POINT CURRENT(Imp) ._ •
MAXIMUM POWER- CONNECTION 1 • ' 1 '
POINT VOLTAGE(Vmp)_V NEC 690.53 DO NOT RELOCATE F
MAXIMUM SYSTEM THIS OVERCURRENTSitcom
VOLTAGE(Voc)_V DEVICEswrCH
SOLAR
SHLITSHORT CIRCUITELECTRIC
CURRENT(Isc)_A O Mla'1LtiELS
AMME
SHOCK HkZAAD
Label Location: IN THE AR
PHOTOVOLTAIC SYSTEM
Label Location: EQUIPPED WITH RAPID ••"
WARNING (DC) (INV) NEC 690.56.C.3
Per •.•-
ELECTRIC SHOCK HAZARD 690.41.13
IF A GROUND FAULT IS INDICATED
NORMALLY GROUNDED
CONDUCTORS MAY BE
UNGROUNDED AND ENERGIZEDLabel L• •
CAUTION ' '•_ ••_
PHOTOVOLTAIC SYSTEM
CIRCUIT IS BACKFEDNEC 690.64.13.4
Label • •
WARNING Code:Per
ELECTRICAL SHOCK HAZARD
DO NOT TOUCH TERMINALSCEC 690.13.13 Label Location:
TERMINALS ON BOTH LINE AND _
LOAD SIDES MAY BE ENERGIZED CAUTION •
IN THE OPEN POSITION DUAL POWER SOURCEPer Code:
DC VOLTAGE IS SECOND SOURCE IS NEC 705.12.13.3
ALWAYS PRESENT WHEN PHOTOVOLTAIC SYSTEM
SOLAR MODULES ARE
EXPOSED TO SUNLIGHT
Label • •
PHOTOVOLTAIC POINT OF �•
•- • • INTERCONNECTION
PHOTOVOLTAIC AC A P• WARNING: ELECTRIC SHOCKPer Code:• sconnec
Per
Code: HAZARD. CEC DO NOT TOUCH • 1
DISCONNECT TERMINALS.TERMINALS ON Conduit
NEC ••1.13.B (CB): Combiner '•
MAY BE ENERGIZED IN THE OPEN . Distribution
(DC): DC Disconnect
POSITION. FOR SERVICE
DE-ENERGIZE BOTH SOURCE _
AND MAIN BREAKER. • • •
Label PV POWER SOURCEIntegrated DC Disconnect
MAXIMUM AC ' '• MAXIMUM AC A (LC): Load Center
OPERATING CURRENT Per Code OPERATING CURRENT
(M): Utility Meter
MAXIMUM AC • ' MAXIMUM AC
OPERATING VOLTAGE V • 1 OPERATING VOLTAGE V P• Point of • •
Label Location: Label Location:
BACKUP LOAD CENTER CAUTION
Code:Per TRI POWER SOURCEPer Code:
NEC 408.4
,84 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM '
THIRD SOURCE IS ENERGY STORAGE SYSTEM
Label • •
CAUTION
DO NOT ADD NEW LOADSPer Code: .•- • •
Per' WARNING
..-
THIS EQUIPMENT FED BY NEC �
_ on: MULTIPLE SOURCES.TOTAL
CAUTION (MS-)RADEV COS,EXCOLUDRINGUMA NNT
TH15 PANEL HAS SPLICED FEED Per • SUPPLY OVERCURRENT DEVICE,
THROUGH CONDUCTORS. NEC 312.8.A(3) SHALL NOT EXCEED AMPACITY
LOCATION OF DISCONNECT AT ENERGY OF BUSBAR.
STORAGE BACKUP LOAD PANEL
Label
Label ... .
NOMINAL ES5110LTAGE 1�Q��40V Location:
CAUTION - MAX AVAILABLE SI IORT Per ..-
DUAL POWER SOURCE Per ..- CIRCUIT FROM ESS= 32A Per 1•.7(D) label t• •- marked in field
SECOND SOURCE IS ARC FAULTCLEARING
ENERGY STORAGE SYSTEM 11ME FROM ESS: 67fT1S
Label Location:
(MS
DATE OF
CALcuLAT�aN:
ENERGY STORAGE SYSTEM ON SITE -
LOCATED WITHIN LINE OF SIGHT Per • -
Label • •
ENERGY STORAGE SYSTEM ON SITE
LOCATED ON ADJACENT WALLPer Code:
Label • •
ENERGY STORAGE SYSTEM ON SITE
LOCATED ON OPPOSITE WALLPer • "
Label • •
(MSENERGY STORAGE SYSTEM ON SITE -
LOCATED INSIDE Per • -
Disconnect
Backup Load Center
ROOFING SYSTEM SPECIFICATIONS 1-1 GROUND ZEP F-1 CAM FOOT V2
DESCRIPTION PV mounting solution for concrete tile roofs. Listed toUL2703 Listed toUL2703
Part#850-1511 Part#850-1564
Works with all Zep Compatible Modules.
Auto bonding UL-listed hardware creates structural and electrical bond.
Q��MPAT�6
rFA /0v
�OMPp�v
�
SPECIFICATIONS Designed for pitched roofs. Installs in portrait and landscape orientations. DC WIRE CLIP HOME RUN CLIP
Listed to UL 1565 Listed to UL 1565
Engineered for spans up to 72"and cantilevers up to 24". Part#850-1509 Part#850-1510
ZS Span has a UL 1703 Class"A" Fire Rating when installed using modules from any O
manufacturer certified as"Type 1"or"Type 2".
i
Attachment method UL listed to UL 2582 for Wind Driven Rain.
50 psf(2400 Pa)front side and 85 psf(4070 Pa) rear side design load rating.
Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements. ARRAY SKIRT END CAP
Zep wire management products listed to UL 1565 for wire positioning devices. Listed to UL 2703 Listed to UL 2703
Part#850-1608 Part#850-1586(Left)
ZS Span grounding products are listed to UL 2703 and UL 467. Part#850-1588(Right)
ZS Span bonding products are listed to UL 2703. `
SPANNER CLAMP V2 MIGHTY HOOK V2 SKIRT GRIP INTERLOCK
Listed to UL 2703 Listed to UL 2703&UL 2582 for Wind Driven Rain Listed to UL 2703 Listed to UL 2703
Part#850-1554 Part#850-1461 Part#850-1606 Part#850-1613
9P
SPANNER BAR (VARYING LENGTHS) SPLICE ASSEMBLY KIT, SPAN HYBRID INTERLOCK
Listed to UL 2703 Listed to UL 2703 Listed to UL 2703
Part#850-1627 Part#850-1625 Part#850-1281
T - 5 L n DOC-0065160 ZS SPAN DATASHEET 2 T - 5 L n DOC-0065160 ZS SPAN DATASHEET 3
POWERWALL
TYPICAL SYSTEM LAYOUTS
Tesla Powerwall is a fully-integrated AC battery system for T WHOLE HOME BACKUP
residential or light commercial use. Its rechargeable lithium-ion
battery pack provides energy storage for solar self-consumption, optional''
time-based control, and backup.
Powerwall's electrical interface provides a simple connection to Solar
any home or building. Its revolutionary compact design achieves
market-leading energy density and is easy to install, enabling
owners to quickly realize the benefits of reliable, clean power. O o O
to
Solar inverter
------------------------ Main panel Backup Gateway Utility meter Grid
including
service disconnect
T=5 L n
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
AC Voltage(Nominal) 120/240 V Dimensions' 1150 mm x 753 mm x 147 mm
Feed-In Type Split Phase (45.3 in x 29.6 in x 5.75 in) �^
Weight' 114 kg(251.3 Ibs)
Grid Frequency 60 Hz
Mounting options Floor or wall mount
Total Energy' 14 kWh Powerwall Whole home -
'Dimensions and weight differ slightly if manufactured before March 2019. backup
Usable Energy' 13.5 kWh Contact Tesla for additional information.
147 mm
Real Power,max continuous 5 kW(charge and discharge) 753 mm (
(29.6 in) 5.75 in)
Real Power,peak(10s,off-grid/backup) 7 kW(charge and discharge)
Apparent Power,max continuous 5.8 kVA(charge and discharge)
Apparent Power,peak(10s,off-grid/backup)7.2<VA(charge and discharge) T o 9 L n PARTIAL HOME BACKUP
Load Start Capability 106 A LRA for each Powerwall
Maximum Supply Fault Current 10 kA Optional
1150 mm I i
Maximum Output Fault Current 32 A (45.3 in)
Overcurrent Protection Device 30 A
Imbalance for Split-Phase Loads 100% Solar
Power Factor Output Range +/-1.0 adjustable
Power Factor Range(full-rated power) +/-0.85
Internal Battery DC Voltage 50 V
Round TripEfficiency'2 90% ENVIRONMENTAL SPECIFICATIONS O
Warranty 10 years Solar Inverter
Operating Temperature -200C to 500C(-4°F to 122°F) ------------------------- Sub panel Backup Gateway Main panel Utility meter Grid
'Values provided for 250C(770F),3.3 kW charge/discharge power.
'AC to battery to AC,at beginning of life. Recommended Temperature 0°C to 300C(32°F to 86°F)
Operating Humidity(RH) Up to 100%,condensing T-s
Storage Conditions -200C to 300C(-4°F to 86°F)
COMPLIANCE INFORMATION Up to 95%RH,non-condensing
State of Energy(SoE):25%initial
Certifications UL 1642,UL 1741,UL 1973, Maximum Elevation 3000 m(9843 ft)
UL 9540,IEEE 1547,UN 38.3
Environment Indoor and outdoor rated
Grid Connection Worldwide Compatibility Powerwall Backup loads Home loads
Enclosure Type NEMA 3R
Emissions FCC Part 15 Class B,ICES 003
Ingress Rating IP67(Battery&Power Electronics)
Environmental RoHS Directive 2011/65/EU IP56(Wiring Compartment)
Seismic AC156,IEEE 693-2005(high) Wet Location Rating Yes
Noise Level @ 1m < 40 dBA at 300C(86°F)
T = 5 L Fi TESLA.COM/ENERGY NA-BACKUP-2021-06-01 TESLA.COM/ENERGY
POWERWALL
Backup Gateway 2
The Backup Gateway 2 for Tesla Powerwall provides energy management
and monitoring for solar self-consumption,time-based control,and backup.
The Backup Gateway 2 controls connection to the grid,automatically
detecting outages and providing a seamless transition to backup power.
When equipped with a main circuit breaker,the Backup Gateway 2 can be
installed at the service entrance.When the optional internal panelboard is
installed,the Backup Gateway 2 can also function as a load center.
The Backup Gateway 2 communicates directly with Powerwall,allowing you
to monitor energy use and manage backup energy reserves from any mobile
device with the Tesla app.
PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS
Model Number 1232100-xx-y Dimensions 660 mm x 411 mm x 149 mm
AC Voltage(Nominal) 120/240V (26 in x 16 in x 6 in)
Weight 20.4 kg(45 lb)
Feed-In Type Split Phase
Mounting options Wall mount,Semi-flush mount
Grid Frequency 60 Hz
Current Rating 200 A
Maximum Input Short Circuit Current 10 kA'
Overcurrent Protection Device 100-200A;Service Entrance Rated'
Overvoltage Category Category IV
AC Meter Revenue accurate(+/-0.2%) 4 e S L R
Primary Connectivity Ethernet,Wi-Fi
Secondary Connectivity Cellular(3G,LTE/4G)2
User Interface Tesla App
Operating Modes Support for solar self-consumption, o
time-based control,and backup
Backup Transition Automatic disconnect for seamless
backup
Modularity Supports up to 10 AC-coupled
Powerwalls
Optional Internal Panelboard 200A 6-space/12 circuit Eaton
BR Circuit Breakers
Warranty 10 years
'When protected by Class J fuses,Backup Gateway 2 is suitable for use in 411 149
circuits capable of delivering not more than 22kA symmetrical amperes.
2 The customer is expected to provide internet connectivity for Backup Gateway
2;cellular should not be used as the primary mode of connectivity.Cellular
connectivity subject to network operator service coverage and signal strength.
COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS
Certifications UL 67,UL 869A,UL 916,UL 1741 PCS Operating Temperature -200C to 500C(-4°F to 122°F)
CSA 22.2 0.19,CSA 22.2 205 Operating Humidity(RH) Up to 100%,condensing
Emissions FCC Part 15,ICES 003
Maximum Elevation 3000 m(9843 ft)
Environment Indoor and outdoor rated
Enclosure Type NEMA 3R
T = 5 L Fi NA 2020-09-16 TESLA.COM/ENERGY
T = SLn
GENERAL NOTES
• DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN
STRING LENGTH
• IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 GD
SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE
ROOF TO NO GREATER THAN 165V (690.12.B.2.1 )
• MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE
CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ J—BOX J—BOX J—BOX J—BOX J—BOX J—BOX
MCI MCI
RETRORT PV MODULES DC-
0 MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV
MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS 1
• THE QUANTITY OF MCIS PER STRING IS DETERMINED BY
STRING LENGTH
— NUMBER OF MODULES BETWEEN MCI UNITS = 0-3
— MAXIMUM NUMBER OF MODULES PER MCI UNIT = 3 jJ—BOXj J—BOX J—BOX J—BOX
— MINIMUM NUMBER MCI UNITS = MODULE COUNT/3 MCI
*Exception: Tesla (Longi) modules installed in locations where
the max Voc for 3 modules at low design temperature
exceeds 165V shall be limited to 2 modules between MCIs.
PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR 1 (2)AWG, PV Wire, 600V, Black DC
MORE INFORMATION
T = SLM
1 �
GENERAL NOTES
• DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN
STRING LENGTH
• IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30
SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE
ROOF TO NO GREATER THAN 165V (690.12.B.2.1) GD
• MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE
CERTIFIED RAPID SHUTDOWN DEVICE (RSD)
DC+ DIODE DIODE DIODE DIODE DIODE DIODE DIODE
MCI
SOLAR ROOF TLES DC-
0 MCIS ARE LOCATED AT DECK LEVEL, JUST UNDER THE 1 DIODE DIODE DIODE DIODE DIODE DIODE DIODE
MCI
TILES IN ACCORDANCE WITH 690.12 REQUIREMENTS
• THE QUANTITY OF MCIS PER STRING IS DETERMINED BY
STRING LENGTH
— NUMBER OF TILES BETWEEN MCI UNITS = 0—10 DIODE DIODE DIODE DIODE DIODE DIODE DIODE
— MAXIMUM NUMBER OF TILES PER MCI UNIT = 10 MCI
— MINIMUM NUMBER MCI UNITS = TILE COUNT/10
DIODE DIODE DIODE DIODE
PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR 1 (2)AWG, PV Wire, 600V, Black DC
MORE INFORMATION
POWERWALL+
ti:oa�,9b
PHOTOVOLTAIC (PV) AND BATTERY ENERGY
STORAGE SYSTEM (BESS) SPECIFICATIONS MECHANICAL SPECIFICATIONS
Model Number 1850000-xx-y Dimensions 1596 x 755 x 160 mm(62.8 x 29.7 x 6.3 in)
Nominal Battery Energy 13.5 kWh Total Weight 140 kg(310 Ib)4
Nominal Grid Voltage(Input/Output) 120/240 VAC Battery Assembly 118 kg(261 lb)
Grid Voltage Range 211.2-264 VAC Solar Assembly 22 kg(49 Ib)
Frequency 60 Hz Mounting options Floor or wall mount
Phase 240 VAC:2W+N+GND 755 mm 160 mm
Maximum Continuous Power On-Grid 7.6 kW full sun/5.8 kW no sun' �--►I
Maximum Continuous Power Off-Grid 9.6 kW full sun/7 kW no sun'
Peak Off-Grid Power(10 s) 22 kW full sun/10 kW no sun'
Maximum Continuous Current On-Grid 32 A output T
Maximum Continuous Current Off-Grid 40 A output
Load Start Capability 118 A LRA
PV Maximum Input Voltage 600 VDC
L
PV DC Input Voltage Range 60-550 VDC
PV DC MPPT Voltage Range 60-480 VDC
T = S L n
M PPTs 4
1596 mm
Input Connectors per MPPT 1-2-1-2
Maximum Current per MPPT(Imp) 13 A
Maximum Short Circuit 15 A
Current per MPPT(I..)
Allowable DC/AC Ratio 1.7
Overcurrent Protection Device 50 A breaker
Maximum Supply Fault Current 10 kA
Output Power Factor Rating +/-0.9 to 1
Round Trip Efficiency 90%2
Solar Generation CEC Efficiency 97.5%at 208 V
98.0%at 240 V
Customer Interface Tesla Mobile App ENVIRONMENTAL SPECIFICATIONS
Internet Connectivity Wi-Fi,Ethernet,Cellular LTE/4G)3 Operating Temperature -200C to 500C(-4°F to 1220F)5
P O W E R W A L L+ PV AC Metering Revenue grade(+/-O.S%) Recommended Temperature 0°C to 300C(320F to 86°F)
Protections Integrated arc fault Operating Humidity(RH) Up to 100%,condensing
circuit interrupter(AFCI),
PV Rapid Shutdown Storage Conditions -200C to 300C(-4°F to 86°F)
Powerwall+ is an integrated solar battery system that stores energy from solar production. Its integrated design and Up to 95%RH,non-condensing
streamlined installation allow for simple connection to any home, and improved surge power capability brings whole Warranty 10 years State of Energy(SoE):25%initial
home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their Maximum Elevation 3000 m(9843 ft)
renewable energy needs. COMPLIANCE INFORMATION Environment Indoor and outdoor rated
PV Certifications UL 169913,UL 1741,UL 3741,UL 1741 SA,UL Enclosure Type Type 3R
KEY FEATURES 1998(US),IEEE 1547,IEEE 1547.1
Noise Level @ 1 m < 40 db(A)optimal,<50 db(A)maximum
Battery Energy Storage UL 1642,UL 1741,UL 1741 PCs,UL 1741 SA,UL
• Integrated battery, inverter, and system controller for a more compact install System Certifications 1973,UL 9540,IEEE 1547,IEEE 1S47.1,UN 38.3 'Values provided for250C(770F).
• A suite of application modes, including self-powered, time-based control, and backup modes Grid Connection United States 2AC to battery to AC,at beginning of life.
Emissions FCC Part 15 Class B 'Cellular connectivity subject to network service coverage and signal strength.
• WI-Fi, Ethernet, and LTE connectivity with easy over-the-air updates 4The total weight does not include the Powerwall+bracket,which weighs an
Environmental RoHS Directive 2011/65/EU additional 9 kg(20 Ile).
Seismic AC156,IEEE 693-200S(high) 'Performance may be de-rated at operating temperatures below 10°C(50°F)
or greater than 430C(1090F).
NA 2021-09-08 T = S L Fi NA 2021-09-08 TESLA.COM/ENERGY
SOLAR SHUTDOWN DEVICE SYSTEM LAYOUTS
The Tesla Solar Shutdown Device is part of the PV Powerwall+with Backup Switch for Whole Home Backup
system rapid shutdown (RSD)function in accordance % ,
with Article 690 of the applicable NEC. When paired X—)
with Powerwall+, solar array shutdown is initiated by '
turning the Powerwall+ Enable switch off, or by pushing
Solar Backup Switch
the System Shutdown Switch if one is present. L_ —
r
ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS -s L_ Meter (t
Load center Meter socket panel Grid
Nominal Input DC Current Rating(IM,) 12 A Electrical Connections MC4 Connector
Maximum Input Short Circuit Current(I5c) 15 A n
Housing Plastic \/
Maximum System Voltage 600 V DC -
Dimensions 125 mm x 150 mm x 22 mm Powerwall+ Backup loads
(5 in x 6 in x 1 in)
W
RSD MODULE PERFORMANCE eight 350 g(0.77 lb)
Mounting Options ZEP Home Run Clip Powerwall+with Backup Gateway 2 for Whole Home Backup
Maximum Number of Devices per String 5 M4 Screw(#10)
M8 Bolt(5/16")
Control Power Line Excitation
Nail/Wood screw �
Passive State Normally open
Solar
Maximum Power Consumption 7 W
Warranty 25years -- -- __---_--- -- /1
250 mm r
COMPLIANCE INFORMATION X M4 Screw Load center Backup Gateway 2 Meter socket panel Grid
I
o e
Certifications UL 1741 PVRSE,UL 3741,
PVRSA(Photovoltaic Rapid
Shutdown Array) 650 mm 150 mm M8 Bolt
RSD Initiation Method External System Shutdown Switch Powerwall+ Backup loads
e o
Compatible Equipment See Compatibility Table below Nail/
Wood Screw
Powerwall+with Backup Gateway 2 for Partial Home Backup
ENVIRONMENTAL SPECIFICATIONS
Ambient Temperature -400C to 500C(-40°F to 122°F)
Storage Temperature -300C to 700C(-220F to 158°F)
Enclosure Rating NEMA 4/IP65 22
m 125 mm Solar
mm T
—L A Meter
UL 3741 PV HAZARD CONTROL (AND PVRSA) COMPATIBILITY Backup panel Backup Gateway 2 Meter socket panel Grid
I
Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with the Powerwall+and
Solar Shutdown Devices.See the Powerwall+Installation Manual for detailed instructions and for guidance on installing Powerwall+and Solar Shutdown
Devices with other modules.
Brand Model Required Solar Shutdown Devices Powerwall+ Backup loads =_
Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Non-backup panel
Tesla Tesla TxxxS(where xxx=405 to 450 W,increments of 5) 1 Solar Shutdown Device per 3 modules'
Hanwha Q.PEAK DUO BLK-G5 1 Solar Shutdown Device per 3 modules O
Hanwha Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules SSS
'Exception:Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to Non-essential loads
two modules between MCIs.
T = 5 L n NA 2021-09-08 TESLA.COM/ENERGY l TESLA.COM/ENERGY
Tesla Module Specifications
N n o t o v o l t a i c Module Electrical Characteristics
Power Class T4205 T42SS T4305
T420S, T425S, and T430S Test Method STC NOCT STC NOCT STC NOCT
Max Power,Pm_(W) 420 313.7 425 317.4 430 321.1
Open Circuit Voltage,Vo<(V) 48.5 45.47 48.65 45.61 48.8 45.75
Short Circuit Current,Ise(A) 11.16 9.02 11.24 9.09 11.32 9.15
Max Power Voltage,V_(V) 40.90 38.08 41.05 38.22 41.20 38.36
Max Power Current,Imp(A) 10.27 6.24 10.36 8.3 10.44 8.37
Maximum Power
The Tesla module is one of the most powerful Module Efficiency(%) 19.3 19.6 19.8
residential photovoltaic modules available. STC 1000 W/m�,25°C,AM1.5
Our system requires up to 20 percent fewer modules NOCT 800 W/m2,20°C,AM1.5,wind speed lm/s
to achieve the same power as a standard system.
The module boasts a high conversion efficiency Mechanical Loading Temperature Rating(STC)
and a half cell architecture that improves shade Front Side Test Load 6120 Pa 1128lb/ft2 Temperature Coefficient of Isc +0.040%/°C
tolerance.
Rear Side Test Load 5190 Pa 1108 lb/ft' Temperature Coefficient of Von -0.260%/°C E
E
Beautiful Solar Front Side Design Load 4080 Pa 185 Ib/ft2 Temperature Coefficient of P_(W) -0.331%/°C o
Featuring our proprietary Zep Groove design, Rear Side Design Load 3460 Pa 1 721b/ftz
35 mm/1.378 in
the all-black module connects easily with Tesla ZS
Hailstone Test 25 mm Hailstone at 23 m/s
components to keep panels close to your
40+/-0.5 mm 1038+/-2 mm 40.9+/-0.08 in
roof and close to each other for a blended aesthetic Mechanical Parameters 1.57+/-0.020in
with simple drop-in and precision quarter-turn
connections. Cell Orientation 144(6 x 24)
Junction Box IP68,3 diodes ❑
Reliability Cable 4 mm2 112 AWG,1400 mm 155.1 in.Length e
Tesla modules are subject to automotive-grade
Connector Staubli MC4 or EV02
engineering scrutiny and quality assurance,
far exceeding industry standards. Glass 3.2 mm ARC Glass
Modules are certified to IEC/UL 61730-1, Frame Black Anodized Aluminum Alloy
IEC/UL 61730 2 and IEC 61215. Weight 25.3 kg 155.8 lb
d
2094 mm x 1038 mm x 40 mm * e
Dimension ? o;
82.4 in x 40.9 in x 1.57 in m E
E E O
E E
Operation Parameters
a
Operational Temperature -40'C up to+85°C o
Power Output Tolerance -0/+5 W
V_&Is,Tolerance +/-3%
984mm 38.7 in
Max System Voltage DC 1000 V(IEC/UL)
Max Series Fuse Rating 20 A
NOCT 45.7+/-2'C
Safety Class Class II
Fire Rating UL Type 1 or 2
Limited Warranty Linear Power Warranty Current vs.Voltage Power vs.Voltage Current vs.Voltage
Materials and Processing 25 years t00% 12 Cell Temp=25-C 500 Cell Temp=25°C 12 Incident Irradiance=
1000Wim=
95% 98% 0 -1000 W/m= 400 -1000 W/m2 O -1000 Wpm=
Extra Linear Power Output 25 years
E e -Soo W/m= -800 W/m2 8 -BOO W/m2
90% G -600 W/m2 300- -600 W/m2 ¢ -600 W/m2
6 -400 W/m2 -W/m2 « 6 -40°W/m2
The maximum Pmax degradation is 2% in the 85% 85% , -Zoo wrm= ;200 -200 wim= 4 -Zoo wrm=
o
1st year and 0.54%annually from the 2nd to 3 80% V 2 a,00 U 2
25th year. 75%
y o , is zo zs ol 0
0 10 20 30 40 50 0 10 20 30 40 50 0 10 20 30 40 50
voltage(V) voltage(v) Voltage(V)
Tesla Module Datasheet T = 5 L n Tesla Module Datasheet T = 5 L n
(TEPV-DS-0001-21) (TEPV-DS-0001-21)