HomeMy WebLinkAboutTimebrline HD Product Approval i
MIAMI-DADE COUNTY
M1AMF PRODUCT CONTROL SECTION
11805 SW 26 Street Room 208
D®atE' 'OF REGULATORY AND ECONOMIC RESOURCES(RER) M,and,Florida 33175 2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315.2599
NOTICE OF ACCEPTANCE (NOA) IVsvW.mlamrnI ado.toxLee maw
GAF
I Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control.Section to be
used in Miami Dade County and other areas where allowed by the Authority Raving Jurisdictionn(AFI7y.
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section(In Miami Dade County)and/or the AIW (in areas other than Miami Dade County)reserve the right to
have this product or material tested for quality assurance purposes. I£this product or material fails to perform in
the accepted manor„the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke,modify,or suspend the use of such product or material within their jurisdiction, RER reserves the right to
revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including tho#ligh Velocity Hurricane Zone of the Florida=Building Code.
DESCRIPTION.GAY Timberline HDe,Timmberine®Natural Shadow*,Timberline NS,Timberline®American
Harvest*,Timberline All,Timberline IiDZ"„ Timberline CS and Fortitude®Shingles
LABELING:Each unit shall beans permanent label with the manufacturer's name or logo,city,state and following
statement:"Miami-Dade County Product Conttal Approved",unless otherwise noted herein..
RENEWAL,of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of thle product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT. The NOA number preceded by the words Miami-Dade County,Florida, and followed by the
expiration date may be displayed in advertising literature. Many portion of the NOA is displayed,then it shall be done
in its entirety.
I�
INSPECTION:A copy ofthis entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the jab site at the request of the Building Official.
This NOA renews and revises NOA# 16-0811.11 and consists of pages I through 7.
i The submitted documentation was reviewed by Freddy Semino
uerx
NOA No.: 194312.04
Mwmonn F of 17K Expiration Date:02/21/22
I�Nasuu,now Approval Date:01/09/20
1
Page i of 7
V
I
RoOF1NG ASSEMBLY APPROVAL
Catego-xy. Roofing
Seib-Category: Asphalt Shingles
Materials: Laminate
Deck Tyne: Wood
SCOPE
This approves GAF Timberline HD',Timberline's Natural Shadolve,Timberline NSi°,Timberline American'
Harvest®,Timberline AI1e,Timberlines HDZ"',Timberline CSe and FortitudeTri Shingles as manufactured by
GAF as described in this Notice of Acceptance.
PRODUCT DESCRITTION
Product Dimensions Test Product Defcrintion
Sneefications
GAF Timberline HDs 13 1/47 x 39 34" TAS 110 Fiberglass reinforced heavy weight asphalt roof
j Manufacturing shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline'Natural 13 :f4L x 39 W TAS 110 Fiberglass reinforced heavy weight asphalt roof
Shadow'and Timberline®NS shingle,with a laminate profile
Manufacturing
Locations 01,2,3,4,S,6,7
GAP T mberlinee American 13 V;x 39%7 TAS 110 Fiberglass reinforced heavy weight asphalt roof
Ilarvese shingle,with a laminate profile
Manufacturing
Locatlons#2,4,,6,9
GAP Timberllne'AH 13 W'x 39'/s" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Man:pacturing shingle,with a laminate profile
Locations#2, 4 6,9
GAF Timberline'HDV 13 Y4"x 39 s/a" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Mamufacturing shingle,with a laminate profile
Locations 91,2,3,4,5,6,7,g,9
GAF Fortitude" 13 Wx 39 s/an TAS 110 Fiberglass reinforced heavy weight asphalt roof
Mwigfaeluring shingle,with a laminate profile
Location#4
GAF Timberline'CS 13"/4"x 39% TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Location#9
WMFWInaC LINTY
NOA No.:19-0312.04
.., , Upirstlon Date:02121/22
Approval Date:01/09/20
Page 2 of 7
I
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City,IN
3. Baltimore,MD
4. Myerstown,PA
S. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
& Shafter,CA
9. Fontana.,CA
i'
I�
f
i
I
i
PH t:,oaoE COaun NOA No.:19.0312.04
,.. Expiration Date:02121/22
Approval Dates O1/09/20
Page 3 of 7
I
ICVIDENCE SUBMITTED
Test Aeeney Test Identifier Test Name/Reoort Date
Underwriters Laboratories,LLC ASTM D3462 4788932264 12/13/19
Underwriters Laboratories,LLC ASTM D3462 4788717529 01/31/19
Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16
Underwriters Laboratories,Inc. ASTM D3462 1I CA48924 10/22/11
Underwriters Laboratories,Inc ASTM D3462 I OCA21994 04/22/11
Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11
!i Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10106
Underwriters Laboratories,hic. ASTM D3462 06CA31580 11130106
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05'
Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories,hic.Center for ASTM D3462ASTM 03NK26444257989 10/17/03
Applied Engineering D3462 05113191
Underwriters Laboratories,LLC TAS 107 4789225994 I t/l/19'
Underwriters Laboratories,LLC TAS 107 4788717529 01/31/19
Underwriters Laboratories,Inc. TAS 107 OINK45803 04/13/94
Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories,Ine. TAS 107 04NK04273 02/20/04
Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NX41811 11/11/02
Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/01
Underwriters Laboratories,Iite. TAS 107 04CA13850 0$130/04
Ills Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies,,Inc. TAS 100 GAF-912-02-01 12/17/18
PRI Asphalt Technologies,Inc. TAS 100 GAF-044-02701 01/13/04
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-1 O1-02-01 11109/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03123/06'
PRI Asphalt Technologiep,Inc. TAS-100 ELK-083-02-01 10/16/02
ELK-094-02-01 10115/02.
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09103
ELK-108-02-01 10/09/03
ELK-109-02-01 10109/03
i
MIA ECOUNTr NOA No.:19-0312.04
Expiration Date:02/21/22
Approval Date:01/09/20
Page 4 of 7
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard PAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W,attached.
5. Nailing shall be in compliance with Detail 19,attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer`s name or logo, city and state of
manufacturing facility,and following statement: "Miami-Dade Comity Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
01MIANtr4DADE couNTY
vv
BUILDING PERMIT MQUIREMENTS
1. Application for building penult shall be accompanied by copies of the fallowing:
1.1 This Notice ofAcceptanco.
1.2 Any other documents required by the Building Official or, the applicable code in order to properly
evaluate the installation of this system,
i
i
it
u: rOANoa 19-0312.04
e:02121/22
Expiration Date:02121122
Approval Date:01/09/20
Page 5 of 7
i
Ii DETAIL A
COURSE LAYOUT
DECK
�I
FULL
5th
1 r OFF 4th
11"OFF 3rd
6"OFF 2nd
FULL 1st, 5-518"Exposure
ii
i
i
I
I
s
i
MIAM6D nac uNTY NOA No.:19-0312.04
� Expiration Date-02/21/22
-M now Approval Date,01/09/20
Page 6 of I
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
FOR TIMBERLINE HDO TIMBERLINO NATURAL SHADOW*AND TIMBERLwe NS
39-3/801
14.1cee-4t7-1/2" 14-1a&.-e1i m
a8 guide line
_ � i B'1, "s b e'1 :$ $ aa-s va
aer iAi .4- _. --s- - ._. .—. (9aernmr9Sgmm)
i -2.1m from bogom ofsb)ngle
si#seal
adhesive
on back
ENHANCED NAILING PATTERN -six nails per shingle"
•mqubod by some local cudoo andmgatiod for enhanced wind mWerage an cedatn'yroduals.
Soo 9m8ad warranty ror details,
These shingles MUST be nailed a nominal V(Mmm l from.bottam of
of shingle,above the cut outs,as shown. Nails must not be exposed.
OVERALL DIMENSIONS AND NAILING PATTERN
FOR TimBERLINE*HDZ7mn TIMBERLINE CS,TIMBERLINE®AH,AND
FORTITUDE'
m)
i
^`741t mm=.445nn
OW-9-1& G5mm•2airrm) Q> •+U2'(165mm-211mn)...
VY-2.112•It3rrm-61mm) 1tY••2-trY'113mm•69 mm}
TARGET
13-1/4"
t337aaa} ?.� ; ., ;;;;' ;,•';•^.:{f: t::� a,::;::: 4::5'i:?�,c`:: `y:3x.,?:?.3;; v >::::off. :.+•.
NAIL ZONE
s-1an6•-9•va• 5-13/16°-YSIs'
(1a8 don-1 mm) i148 mm-194 mm)
FdCMaivaMNaofe
i
I
i
END OF THIS ACCEPTANCE
I
11AM4fY1DE EOUNTY- NOA NO 19-0312.04
" " I xpiratlon Date:02411,22
Approval Date;01/69/20
y Page 7 of 7