Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY CALCS & MANUAL J - 6513 ALEMENDRA(1)
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: Junsdiction: Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2} 1. New construction or existing New(From Plans) 10. Wall Type�1432.0 sgft.) insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int insul,Exterior R=4.1 1224.00 ft2 g y p y b.Frame-Wood,Adjacent R=11.0 208.00 ftz 3. Number of units,if multiple family 1 c.NIA R= ftz 4. Number of Bedrooms 3 d.N/A R= ftz 5. Is this a worst case? Yes 11.Ceiling Types (1783.0 sgft_) Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ftz 6. Conditioned floor area above grade(ft2) 1753 b.Knee Wall(Vented) R=19.0 30,00 ft2 Conditioned floor area below grade(ft2) 0 c.NIA R= ftz 7. Windows(151.4 sgft.) Description Area 12.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 795 a. U-Factor: S91,U=1.02 111.36 ftz SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ftz 13.Goofing systems kBtu/hr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8, Skylights Area c. U-Factor:(AVG) NIA ftz 15.Hot water systems SHGC(AVG): NIA a.Electric Cap:40 galions 9. Floor Types (1753.0 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ftz b. Conservation features b.NIA R= ftz None c.NIA R= ft2 16.Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 1 hereby certify that the plans and specifications covered by Review of the plans and � � St this calculation are in compliance with the Florida Energy specifications covered by this , __ ; p Code. calculation indicates compliance with the Florida Energy Code. ¢ rrrr n. f;: �,.�,• PREPARED BY: Before construction is completed W DATE: �-�2'2�29 this building will be inspected for �} ,I', compliance with Section 553.908 * ,� 1 hereby certify that this building,as designed,is in compliance Florida Statutes. , with the Florida Energy Co , OWNER/ NT: BUILDING OFFICIAL: DATE: ��'",� DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-seated in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: ISO Street THEWINDSOR Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_SEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER SEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 159 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' ___ 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 W _—_ 0 1 0 3 Slab-On-Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab-On-Grade Edge Insulatio M.BATH 7 ft 0 61 ft ____ 0 1 0 5 Slab-On-Grade Edge Insulatio LAUDRY 1 ft 0 36 ft' 0 1 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BEDROOM 2 121t 0 1 So ft' — 0 1 0 7 Slab-On-Grade Edge Insulatio DINING/GREAT 50 It 0 588 ft' _- 0 1 0 8 Slab-On-Grade Edge Insulatio KITCHEN lift 0 209 W _ 0 1 0 9 Slab-On-Grade Edge Insulatio BATH 511 0 50 ft2 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft' 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 _ 0 1 0 12SIab-OnGrade Edge Insulatio BEDROOM 3 14 ft 0 169 ft. 0 1 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847ft' Oft' Light N 0.6 No 0.9 No 0 18.4 / ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1753 fN N N CEILING # Ceiling Type Space R-Value Ins Type Area - Framing Frac Truss Type 1 Under Attic(Vented) MASTER BEDRO 30 Blown 224 ft- 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft- 0.1 Wood 3 Under Attic(Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) M.BATH 30 Blown 61 ftZ 0.1 Wood 5 Under Attic(Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic(Vented) KITCHEN 30 Blown 209 ft- 0.1 Wood 9 Under Attic(Vented) BATH 30 Blown 50 ft' 0.1 Wood 10 Under Attic(Vented) HALL 30 Blown 25 ft' 0.1 Wood 11 Under Attic(Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic(Vented) BEDROOM 3 30 Blown 169 ft. 0.1 Wood 13 Knee Wall(Vented) DININGIGREAT 19 Blown 30 ft2 0Al Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below n 1 NE=>SW Exterior Concrete Block-Int InsWASTER BE 4.1 16 0 8 0 128.0 8 0 0 0.3 0 2 SW=>NE Exterior Concrete Block-Int InsiMASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 3 NW=>SE Exterior Concrete Block-Int InstMASTER BE 4.1 14 0 8 0 112.0 ft- 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below L�k-4 NE=>SW Exterior Concrete Block-Ind InsUASTER BA 4A 8 0 8 0 64.0 R2 0 0 0.3 0 - 5 NE=>SW Exterior Concrete Block-Int Insul M.BATH 4.1 7 0 8 0 56.0 R' 0 0 0.3 0 - 6 NE=>SW Exterior Concrete Block-Int InsElEDROOM 2 4.1 12 0 8 0 96.0 R2 0 0 0.3 0 -7 SW=>NE Exterior Concrete Block-Int Ins61NING/GRE 4.1 30 0 8 0 240.0 IF 0 0 0.3 0 - 8 NW=>SE Exterior Concrete Block-Int InsOINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 _9 SW=>NE Exterior Concrete Block-Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 _10 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft� 0 0 0.3 0 _11 SE=>NW Exterior Concrete Block-Ini Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0.3 0 _12 SW=>NE Exterior Concrete Block-Int Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 _13 NE=>SW Exterior Concrete Block-Int InsBEDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 _14 SW=>NE Exterior Concrete Block-Int InsBIEDROOM 3 4.1 1 0 8 0 8.0 IF 0 0 0.3 0 15 N=>S Garage Frame-Wood BEDROOM 3 11 26 8 208.0 IF 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Ft Width Fteight Area 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7ft- WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32A ft 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft- 1 ft 0 in 1 ft 4 in None None _ 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 162 ft2 1 It 0 in 1 ft 4 in None None _ 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 W 1 ft 0 in 1 ft 4 in None None _ 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 It 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 806 ft' 806 ft 26 ft aft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12r2021 1:15 PM EnergyGaugefsl USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15 34.8 kBtu/hr cfrn 0.85 1 sys#1 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None DUCTS / —Supply--- --Return-- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool _ 1 Attic 6 195 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 7 TEMPERATURES Programablee 1Thermostaf[t:lN [[ 11 Ceiling Fans: fXI fXI (XI f[X11 Dec Heat ng (XI Jan 4x1 Feb [XI Mar Apr May JA May un r ]Jul i ]Aug I ]Sep Oct NovOct Nov [ ]DDec ec Vent mg II 77 Jan 111 Feb II�X1l Mar Jun [ ]Jul [ ]Aug [ ]Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) PAM 78 M 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PAM 68 68 M 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 6 68 8 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(S Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M.BATH Default(S lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(S lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(S lbs/sq.ft. ft2 ft 0.3 DINING/GREA7 R Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN 1/12/2021 115 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Defau@(8 lbs/sq.ft. ft. ft 0.3 BATH Defau@(8 lbs/sq.ft. ft' ft 0.3 HALL DefauR(8lbs/sq.ft. ft' ft 0.3 FOYER Default B lbs/ .ft. ft' ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 6 of 6 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST.LUCIE COUNTY City.State.Zip: Fr.PIERCE,FL, Permit Number: U Owner Jurisdiction: _ Design Location: FL,Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soil shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. ravines within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors I skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind oinino and wirina- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1112/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index,the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1224.00 ft= b.Frame-Wood,Adjacent R=11.0 208.00 ft- 3. Number of units,if multiple family 1 c.N/A R= ft= 4. Number of Bedrooms 3 d. N/A R= ft= 5. Is this a worst case? Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1753.00 ft= 6. Conditioned floor area(W) 1753 b.Knee Wall(Vented) R=19.0 30.00 ft' 7. Windows** Description Area c.N/A R= ft' a. U-Factor. Sgl,U=1.02 111.36 ff= 12.Ducts,location&insulation level R ft' a.Sup:Attic,Ret:Attic,AH:Attic 6 195 SHGC: SHGC=0.29 b. U-Factor. Sgl,U=1.11 40.00 ft= SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft= a.Central Unit 34.8 SEER:15.00 SHGC, d. U-Factor: N/A ft= SHGC: 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): WA ft2 a.Electric Cap:40 gallons SHGC(AVG): NIA EF:0.97 b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1753.00 ft- Credits(Performance method) None b.N/A R= ft, c.N/A R= ft= 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) �040 in this home before final inspection. Otherwise, a new EPL Display Card will be completed y �° based on installed Code compliant features. Builder Signature: `- Date: Address of New Home: �� ��j � �a�� City/FL Zip: } Q WF *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 e Project Summary Date: wrightsoft Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LN..FT.PIERCE.FL34946 Pinre'.772-466-6799 Fa 772466-6796 Emaii:QUICKCA.LC-@AOL.CAM Project Information For. WYNNE DEVELOPMENT THE W INDSOR,FT.PIERCE,FL Notes: Design Information Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Ducts 6191 Btuh Duds 9337 Btuh Central vent(0 cim) 0 Btuh Central vent(0 cim) 0 Btuh n Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 27734 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenisensibleload 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Duds 2546 Btuh Central vent(0 cfm) 0 Btuh Heat' Coolingg (none) Area(ftz) 1753 1753 Equipment latent load 5041 Btuh Volume(tN) 16478 16478 Airchanges/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 29511 Btuh Equiv.AVF(dm) 104 55 Req.total capacity at0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A 030 Cond 25HBC536A 030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Bluh@47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cim Actual airflow 1160 drn Airflowfactor 0.042 clm/Bluh Airflowfactor 0.045 cfm/Btuh Sbtepressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=36 OF Backup: Input=7kW, Output=23009 Btuh.100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. w_r7ghLsoft' 2021.1an1213:18:18 RigitSUf OUNry r5 1201919.021 RSU08101 Page 1 ...Du rfs\WdghsDft HVAMWYNNE-7HEWINDSOP p Calc=MJ8 Frwd Doorfa�s:N I wrightsW Right-A)Worksheet Dabe: Entire House Dat By. QUICK CALCS, INC. 317 ST.L11CIE LN.,FT.PIERCE,FL 34946 Phom 772-466-6799 Fax 772-466-6796 Email:QUICKC4LCS@AOL.COM 1 oom name Entire House BEDROOM 2[loom aosed vai 207.6 ft 41D ft 3oom height 9.4 ft d 9A Itheatlmol 400m dlmensions 74.0 x 20.0 ft 5 area 1753.0 ft' 280.0 IF Ty Construcion U-value Or HTM Area OF) Load Area (ftn Load number (BIuh4F'FI (BWh41r) or penmeter (ft) (BNh) or perimeter (ft) (Ruh) Heat I Cool Gros N/P/S Heat Cool Gross NIPS Heat Cool 6 13A-4= 0.143 n 4.00 2.55 649 596 2386 1517 66 66 263 167 1Ac1om 1270 n 35.56 34.77 15 0 533 522 0 0 0 0 4A5-2om 0.770 n 21-56 1931 38 0 6l5 730 0 0 0 0 W 13A-4ocs 0.143 ne 4A0 2S5 27 27 106 68 0 0 0 0 11 vJ1 13A-4ocs 0.143 a 4.00 2-55 141 100 400 255 0 0 0 0 'r---G 1Atl= 12.70 e 35.56 87.06 20 1 711 1741 0 0 0 0 LL--DD 11DO 0.390 a 1092 11.31 21 21 229 238 0 0 0 0 W 13A-4ocs 0.143 se 4.00 2S5 27 27 106 68 0 0 0 0 VL--G 13A4= 0.143 s 4A0 255 536 530 2121 1349 188 188 -753 479 IA-dom 1270 s 3556 34.77 6 6 213 209 0 0 0 0 13A-4ocs 0.143 w 4.00 2,55 320 255 1022 649 132 108 432 275 1Aclom 1270 w 3566 54M 12 1 416 636 12 1 415 636 IAc1om 1270 w 35.56 54.53 12 1 427 654 12 1 427 6M 4A5-2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-0s 0.091 2.55 128 254 254 647 326 0 0 0 0 C 16A30md 0.032 - 0.90 2,32 1753 1753 1571 4067 280 290 251 650 F 22P-tp1 0989 - 27.69 0.00 1753 206 5748 0 280 41 1136 0 I 6 c)AED evirson, 397 488 Envelope IDWgaln 18331 15285 3576 3349 12 a) Infiltra5on 3211 905 729 205 b) Roomvencation 0 0 0 0 13 Intemalgains Omlpant@ 230 1 230 0 0 Appliarxesfobrer 0 0 Subbbl(lines6to13) 21542 16420 4405 3554 Lessexamalload 0 0 0 0 Lesstansiar 0 0 0 0 Redistribution 0 0 0 0 14 Subtoia 21542 16420 4405 3554 15 DuCloads 299/. 57% 6191 9337 29% 57% 1266 2021 Total room load 27734 25757 5671 5g.5 Air required(drn) 1160 1160 237 251 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. mpw 2021-dan1213:18:18 RigkSute®lhi�ersa1201919.021 RS1.108101 Page 1 ...Donmarts\Wdgtis,RM/ACkWYNN2.THEWINDSORnp Celc=W8 Frord Dooriares:N �+wrghtsoft° RighW@ Worksheet Job: Entire House Date: QUICK CALLS, INC. By, 317 ST.LUCIE LN.,Fr.PIERCE,FL 34946 Phore:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@AOL.COM 1 1 Room name WIC MASTER BATH 21 Exposed wall 0 ft 9.0 ft 3 Room height 9.4 ft heaVcool 9.4 ft heall000l 4 Room dimensions 7.0 x 9.0ft 7.0 x 9.0 ft 5 Room area 63.0 fF 63.0 fF Ty ConsGucion U-value Or HTM Area Load (� Load number (BUhAF-°Fj (BWh/fF) or perimeter (ft) (Bwh) 000rpedmeter (ft) (Bluh) Heat Cool Gross N/P/S Heat Cool Gross NiPiS Heat Cool 6 13A4ors 0.143 n 4.00 2S5 0 0 0 0 0 0 0 0 1Ac1om 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 w 13AA= 0.143 ne 4.00 2S5 0 0 0 0 0 0 0 0 11 13A-006 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 a 3556 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 1344ors 0.143 se 4A0 2S5 0 0 0 0 0 0 0 0 U�1 13A-4= 0.143 s 4A0 2.55 0 0 0 0 85 85 339 215 t-G 1Acicm 1270 s 35,56 34.77 0 0 0 0 0 0 0 0 v� 13A-0ors 0.143 w 4.001 2S5 0 0 0 0 0 0 0 0 I--C 1Ac1om 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 L�-GG 1Ac1om 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4AS2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-0sv 0.091 2,55 128 0 0 0 0 0 0 0 0 C 1BA-30md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 22A-WI 0989 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AEDe=rsion -10 -28 Envelope ioslgain 55 136 644 334 12 a) Irrfllaabon b) Room venblabon 0 0 160 40 0 0 0 0 13 Inkmal gains Omrpan6@ 230 0 Appliano2slolher 0 0 0 0 0 Subto*al(linesft13) 56 136 804 379 Lesse4amalload 0 0 ��^�r 0 0 0 0 RedLlnbudon 0 0 0 0 80 14 Subbtal 136 0 0 4 379 15 Duct loads 29% 57% 16 77 29% 57% 231 216 Total mom load 73 214 1036 595 Air required(dm) 3 10 43 27 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed +I wr�9!`isoTt^ 2021J.1213:18:18 .9 A RigY-TFEWINDSORrLp 919.021 RSU08101 Paget ...CaamenMWdgh�ft HVAC\WYNNE-TFiE WINDSORnp Calc=Nl18 FroNDoorfacesN wrightsot Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Prom 772466-6799 Fax:772-466-6796 Email:OUICKCALCS@AOL.COM 1 Room name MBATH KITCHEN 2 E)po�aecl%dl 8.0 ft &0 It 3 Room heght 9.4 ft heaNaxol 9A ft heat(=l 4 Rcom dimensions 7.0 x 8.0 ft 1.0 x 172.0 ft 5 Room area 56.0 fP 172.0 IF Ty Construction U-value Or HTM Area (T) Load number (BWhfiF-`F) (BWhfi� or perimeter (ft) (Bhih) oorperimeter (ft) (f3Wh) Heat Cool Gras NIPS Heat Cool Gros NIPS Heat Cool 6 y/ 13A-4as 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1�-GC 1Ao1om 127C In 35M 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13AAc s 0.143 ne 4.00 2,55 0 0 0 0 0 0 0 0 11 13AA= 0.143 a 4.00 2S5 0 0 0 0 0 0 0 0 F--C 1Ac1an 1270 a 3556 87.06 0 0 0 0 0 0 0 0 III --DDD 11DO 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 W 13A-4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 W 13A4= 0.143 s 4.00 2.55 75 69 277 176 0 0 0 0 I-G to-clorn 1270 s 35.56 34.77 6 6 213 209 0 0 0 0 13A4oes 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 5453 0 0 0 0 0 0 0 0 G 1Aclom 1270 w 35.55 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-Osv 0.091 - 2.55 128 0 0 0 0 75 75 192 96 C 16A30md OA32 - 0.90 2.32 56 56 50 130 172 172 154 399 F 22A-tpl - 0989 - 27.69 0.00 56 8 222 0 172 8 222 0 I 6 c)AEDe rson -38 34 Envelope loss/gain I 762 477 567 462 12 a) Infiltration 142 40 0 0 b) Roornwafilafion 0 0 0 0 13 Internal gains: O=pants@ 230 0 0 0 0 Appliancesbther 0 0 Subtotal OhIas6fn 13) 904 517 567 462 Lees emmal load 0 0 Lestransfer 0 0 0 0 Redistributon 0 0 0 0 14 Subtotal 904 517 0 0 566 15 Dud loafs 29% 57% 260 294 9%2 57% 163 263 Total room load 1164 811 730 725 Air required(am) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed .9 wrlglstsolY-... RigF J 9t9.021 RS 2021J 1213:1818 DnrMWrgtoftHUACWNNE-THEWINDSORrup CaIc=M6 FroftDoorfaces:N Page - r}F wrightsoflt° Right-J®Worksheet Job: Entire House Sad. By. QUICK CALCS, INC. 317 ST.LUCIE LN.,FT.PIERCE,PL 34946 PInre:T2466-6799 Fax:772466-6796 EMIL QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM2 2 Exposedwall 5.0 it 42.6 ft 3 Room height 9.4 ft heav000l 9.4 ft heavocol 4 Room dimerds s 9.0 x 5.0 2 1.0 x 204.0 ft 5 Room area 45.0 fF 204.0 fF Ty Construction U-value Or HTM Area () Load Area (fl Load number (BWIVRF-°9 (BLW or perimeter (it) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross N/P/S Heat Cool Gros NPiS Heat Cool 6 y/ 13A-4ocs 0.143 n 4.00 255 47 47 188 120 132 132 527 335 I-C 1Ac1om 1270 n 3556 34.77 0 0 0 0 0 0 0 0 �--G 4A5-2om 0.770 n 21.56 1931 0 0 0 0 0 0 0 0 W 13A-0as 0.143 ne 4.00 2.55 0 0 0 0 27 27 106 68 11 13A-4oa 0.143 a 4.00 2.55 0 0 0 0 65 65 259 164 F--G 1Actom 1270 a 35.56 87D6 0 0 0 0 20 1 711 1741 I-D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 27 27 106 68 13A-4= 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 t-G 1Ac1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 YYY��t111 13A4as 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 �--G IA-ctom 1270 w 35.55 54M 0 0 0 0 0 0 0 0 LI--GG to-ctom 1270 w 3556 5453 0 0 0 0 0 0 0 0 4A5.20m 0.770 w 2156 46.63 0 0 0 0 0 0 0 0 P 12C-ow 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 164-30md 0.032 - 0.90 2.32 45 45 40 104 204 204 183 473 F 22A-tpl 0.989 - 27.69 0.00 45 5 138 0 204 43 1179 0 1 6 c)AEDewcnson .17 -99 Entelopelossrgain 367 207 3599 3065 12 a) Infiltration 89 25 758 214 b) Roomventilaton 0 0 0 0 13 Intemalgaim Ooarpants@ 230 0 0 0 0 Appiortoes'otlter 0 0 Subhltal(lines6b13) 456 232 4357 3299 Less edemal load 0 0 0 0 Less hartsfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 456 232 4357 3299 15 Ductloads 29% 57% 131 132 29% 579/6 1252 1876 Total room load 587 364 5609 5175 Air required(dm) 25 i6 235 233 _ Calculations approved bvACCA to meet all requirements of Manual J 8th Ed .i.�wr�9rtityoft- 2021-Jar,1213:18:18 - MghiSULSUnversal 201919.021 RSUD8101 Page ...Doamer6\WdgNsoft WAC\W7NNE-THEWINDSORnp Calc=M18 FrorlDoorfacexN ► wrghtsofr RighW@ Worksheet Job Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,Fr.PIERCE,FL 34946 Pbnre:772-0 M799 Fa 772-466-6796 Email:OUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 Exposdvall 18.0 It 13.0 ft 3 Room height 9.4 it heatlmol 9A ft heaVocol 4 Room dlmmone 1.0 x 92D ft 7.0 x 6.0 ft 5 Roomarea 92.0 fF 42.0 fF Ty Construction U-value Or HTM Area � Load number ( t Load Area ( (BWh4F-°7r (BWh4f'� or perimetar (ft) (SWh) or perimetar (ft) (afuh) Heat Cool Gross N/P/S Heat Cool Gros N/PS Heat Cool 6 13A-4o s 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 127C n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 1931 0 0 0 0 0 0 0 0 W 13A4a 0.143 re 4.00 2.55 0 0 0 0 0 0 0 0 11 V 13A-4= 0.143 a 4.00 255 56 35 142 90 0 0 0 0 t—C 1Actom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 I—D 11DO 0.390 a 1092 11,31 21 21 229 238 0 0 0 0 W 1344ors 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 13A4= 0.143 s 4.00 255 0 0 0 0 56 56 226 144 1Ac1om 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A-4om 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 5453 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 54.63 0 0 0 0 0 0 0 0 4AS2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-OS'd 0.091 - 2,55 128 113 113 287 145 66 66 168 84 C 16A-30md 0A32 - 0.90 2.32 92 92 82 213 42 42 38 97 F 22A-tpl 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 f 6 c)AED e=rson 49 -24 Envelopelossaain 1239 637 791 301 12 a) Infiltration 107 30 107 30 b) Roomventitaton I 0 0 0 0 13 Intamal gains: Oavpan5@ 230 0 0 0 0 Applertoesrother 0 0 Subtotal(fires 6to 13) 1346 667 8% 331 Les eldemal loac 0 0 Lose 0 0 0 0 s Redistribution 0 0 0 0 14 Subtotal 1346 667 0 0 898 331 15 Ductloads 29% 57% 387 379 29% 57% 258 188 Total room load 1733 1047 1156 520 Airrequired(Qrr.) 72 47 48 23 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed •-� wr7g►fisoR' 2021JarF1213:18:18 RigttSute@Lhwrsa1201919.021 RSU08101 Page5 ...Dowrar6 M1 lW6gtboRHVACIWYNNE-THEWINDSORnp Calc= 6 Frord Doorfaws:N F�t wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 Phore:772-466-6799 Fax 772466-6796 Email:QUICKCALCS@4OL.COM 1 1 Room name GREADDINING Rcom7 2 Elyowdwall 50.0 It 13.0 ft 3 Room height 9.4 ft heav000l 9.4 t heat/cool 4 Roam dimensons 1.0 x 567.0 ft 13A x 13.0 ft 5 Room area 557.0 iF 169.0 fF Ty Consbuction U-value Or HTM Area (ff) Load Area Load number (BWhdt *9 (BWhM) or perimeter (ft) (BWh) or perimeter (ft) (BNh) Heat Cool Gross N/P/S Heat Cool Grow NrP/S Heat Cool 6 T 13A4o s 0.143 n 4.00 2.5E 282 244 978 622 122 107 429 273 �CG tAclom 1270 n 3556 34.77 0 0 0 0 15 0 533 522 4A5-2om 0.770 n 2156 1931 38 0 815 730 0 0 0 0 W 1a44os 0.143 ne 4.00 2.M 0 0 0 0 0 0 0 0 U�1 11 `D 13A4o s 0.143 a 4.00 255 0 0 0 0 0 0 0 0 1Ao1= 1270 a 3556 87.06 0 0 0 0 0 0 0 0 11DO 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 w M40 s 0.143 se 4.00 255 0 0 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 t-C 1Acicm 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-4ors 0.143 w 4.00 255 188 147 589 375 0 0 0 0 1Aclom 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 G 1Acl m 1270 w 35.56 54.53 0 0 0 0 0 0 0 0 4MS2om 0.770 w 2156 45.63 41 2 880 1862 0 0 0 0 P 12C-Ow OD91 - 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 .7 567 508 1315 169 169 151 392 F 22A-yl 0989 - 27.69 0.00 567 50 1385 0 169 13 360 0 6 c)AED e=rsan 307 -100 Er Tope losstgain I 5154 5210 1474 7086 12 a) Infiltration 889 251 231 65 b) Room ventilation 0 0 0 0 13 Internal gains: Ooarpants@ 230 0 0 1 230 Appliarlces/olher 0 0 Subotal Oines6to 13) 6043 546 11705 1381 LessexInmal load 0 0 Lessfiansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6043 5461 0 0 81 15 DUCloads 29% 57% 1737 3105 29% 57% 490 490 785 Total room bad 7780 8566 Airmquired(cfir.) 325 386 2195 2167 92 98 Calculations awroved bvACCAto meet all requirements of Manual J 8th Ed wH9MLsoPt^A ... Rigk sa1207979.027 2021-Jn1213:18:18 Oomr5lWrgluftHUACWNNE-THEWINDSORn CaIc=MI6 FromOoorfaosN Page Duct System Summary o ; - - wrightsoft® e Entire House y QUICK CALCS. INC. 317 ST.LUCIE LN.,FT.PIERCE,FL 34946 PInre:772-466-6799 Fax 772-466-6796 Email:QUICKCALCS@40LCOM For. WYNNE DEVELOPMENT THE W INDSOR,FT.PIERCE,FL Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowestiricton rate 0 in/1OOft 0 in/100ft Actual air 9ow 1160 cfrn 1160 cfm Total effective length(TEL) 0 It Supply Design Htg Gig Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (01m) (Cfm) FIR (in) (in) Mat Ln(R) Ln(it) Trunk BATH h 364 25 16 0 0 OX0 ShMt 0 0 BEDROOM C 2788 119 126 0 0 OX0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 0x0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 OX0 ShMt 0 0 BEDROONLA C 2788 119 126 0 0 OX0 ShMt 0 0 ENTRY h 1047 72 47 0 0 0x0 ShMt 0 0 GREATID tISIG C 2855 108 129 0 0 OX0 ShMt 0 0 GREAVDINING-A C 2855 108 129 0 0 0x0 ShMt 0 0 GREAT(DINING-B C 2855 108 129 0 0 OX0 ShMt 0 0 KITCHEN C 725 31 33 0 0 OX0 ShMt 0 0 LAUNDRY h 520 48 23 0 0 Ox 0 ShMt 0 0 M.BATH h 811 49 37 0 0 OX0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 OX0 ShMt 0 0 RWM7 C 2167 92 98 0 0 OX0 ShMt 0 0 WIC C 214 3 10 1 0 0 Ox0 ShMt 0 0 Return Branch D-tail Table Grille Htg Gig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfin) (Cfin) (ft) FIR opm) (in) (in) Opening(in) MatTrunk rb1 Ox0 1 1160 1160 0 0 0 0 Ox 0 ShMt 40- Wrightsoft- 2021-Jan1213:18:19 �, -w...-. w--rvrv•..w FLgttSLiteg Uri a 1201919A21 RSU08101 Page t AC+CA ...Do rislWngiUoflHVAQWVNNE-THEWINDSORnp Calc=MIB Frorf Doorfacas:N