Loading...
HomeMy WebLinkAboutBuilding PlansST, LUCIE COUNTY TRAFFIC 1 01 � 4 IskZA 1101 Z 1#11I)NIMI-Im 3158 WILL FEE ROAD FORT PIERCE, FL. 34982 ST. LUCIE COUNTY BOARD OF COMMISSIONERS A:4 Chris Dzadovsky District No.1 Chair Sean Mitchell District No.2 Vice -Chair Linda Bartz District No.3 Frannie Hutchinson District No.4 Cathy Townsend District No.5 CONSTRUCTION DOCUMENTS PERMITTING SET: 09/27/2021 DRAWING INFORMATION O Z W A0.0 A1.0 A2.0 A3.0 A4.0 A5.0 A6.0 A7.0 A8.0 A9.0 A10.0 M-1 M-2 M-3 E-1.0 — E-2.0-t - INDEX OF DRAWINGS DRAWINGS LIST ISSUE DATE I REVISIONS GENERAL NOTES: 1. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENTS, DESIGN AND EXTENT OF THE WORK AND ARE PARTIALLY DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGH -IN MEASUREMENTS, OR TO SERVE AS SHOP DRAWINGS OR PORTIONS THEREOF. 2. PRIOR TO START OF CONSTRUCTION, THE CONTRACTOR AND ALL THE SUBCONTRACTORS SHALL VERIFY DIMENSIONS AND COORDINATE EXISTING CONDITIONS OF THE BUILDING WITH THE PLANS AND SPECIFICATIONS, THEY SHALL REPORT ANY INCONSISTENCIES OR ERRORS IN THE ABOVE, TO THE ARCH ITECT/ENG IN EER, BEFORE COMMENCING WORK. THE CONTRACTOR AND HIS SUBCONTRACTORS SHALL LAY OUT THEIR WORK FROM ESTABLISHED REFERENCE POINTS AND BE RESPONSIBLE FOR ALL LOCATIONS OF NEW RECEPTACLES AT THE STATIONS INDICATED. THE ARCHITECT SHALL BE NOTIFIED, PRIOR TO COMMENCING ANY WORK, OF ANY ERRORS OF DISCREPANCIES I BETWEEN PREPARED DRAWINGS AND FIELD CONDITIONS. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS, GENERAL NOTES OR OTHER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCH ITECT/ENGINEER IN WRITING OF SUCH OMISSION OR ERROR PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION. 3. THE GENERAL CONTRACTOR SHALL PROVIDE THE OWNER WITH A SET OF AS-BUILTDOCUMENTS FOR THIS WORK, UPON PROJECT COMPLETION. 44. THE DRAWINGS AND SPECIFICATIONS PREPARED BY THE ARCH ITECT/ENGI N E ER AIRE INSTRUMENTS OF THE ARCHITECT SERVICE THROUGH WHICH THE WORK TO BE EXECUTED BY THE CONTRACTOR IS DESCRIBED. ALL COPIES OF THEM, EXCEPT THE CONTRACTOR'S RECORD SET, SHALL BE RETURNED TO THE ARCHITECT UPON COMPLETION OF THE WORK. 5. CONTRACTOR SHALL BE THOROUGHLY FAMILIAR WITH THE DRAWINGS AND SCOPE PRIOR TO COMMENCING WORK. ALL DIMENSIONS SHALL BE FIELD VERIFIED. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER, AND WITH INFORMATION FURNISHED BY THE OWNER 6. THE CONTRACTOR SHALL PERFORM NO PORTION OF THE WORK REQUIRING S16MITTALAtill REVIEW­_0F SHOP DRAWINGS, PRODUCT DATA SAMPLES OR SIMILAR SUBMITTALS UNTIL THE RESPECTIVE SUBMITTAL HAVE BEEN APPROVED BY THE ARCH ITECT/ENG IN EER. SUCH WORK SHALL BE IN ACCORDANCE: WITH APPROVED SUBMITTALS. A w A 8. THE GENERAL CONTRACTOR IS TO MAINTAIN A COMPLETE, AND UP-TO-DATE SET OF DRAWINGS ON THE JOB ALL TIMES, INCLUDING CONTRACT DOCUMENTS AND SHOP DRAWINGS. 9. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL LABOR, MATERIALS, EQUIPMENT AND OTHER ITEMS NECESSARY TO COMPLETE THE WORK AND / OR QUALITY SPECIFIED, CALLED FOR OR INFERRED BY THESE DRAWINGS UNLESS OTHERWISE NOTED. I 10. IN THE EVENT THAT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN OR, THE DRAWINGS, THEN THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR NOTED. 11. MATERIALS SHALL BE NEW, OF QUALITY SPECIFIED, AND DELIVERED IN AMPLE QUANTITIES TO PREVENT DELAY OF WORK. MANUFACTURER'S DIRECTIONS FOR APPLICATIONS, INSTAL LATION AND METHODS SHALL BE FOLLOWED. gq;ll; 14, NO WORK SHALL BE STARTED TILL ALL SHOP DRAWINGS HAVE BEEN SUBMITTED AND APPROVED BY BUILDING DEPARTMENT. 15. THE GENERAL CONTRACTOR SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH. TRASH AND DEBRIS REMOVAL SHALL BE MADE EACH DAY. AT COMPLETION OF PROJECT, THE GENERAL CONTRACTOR SHALL REMOVE FROM THE PREMISES ALL RUBBISH, IMPLEMENTS, AND SURPLUS MATERIALS AND LEAVE THE PREMISES CLEAN AS ENCOUNTERED BEFORE THE START OF CONSTRUCT11ON ACTIVITIES. ALL TEMPORARY STRUCTURES ARE TO BE REMOVED 16. CONTRACTOR SHALL OBTAIN ABATEMENT ASBESTOS RESPOND FOR AREAS OF WORK REQUIRING DEMOLITION BEFORE COMMENCEMENT OF ANY DEMOLITION ilk F-174 I LojiLM-Al NMI ION01111:1112101 I aftilslilk magnololyalmigglig Inums flyfflom w w 2. CARPET TILE PRODUCT DATA SHALL INCLUDE SPECIFIED TESTS PASSED, MSDS SHEETS, DESCRIPTION OF ADHESIVE, RUBBER BASE, TRANSITION STRIPS AND EDGE STRIPS, INSTALLATION INSTRUCTIONS, AND CERTIFICATION OF FIRE TEST ANN SMOKE PERFORMANCE. 3. CARPET TILE SHALL MEET MANUFACTURERS WRITTEN REQUIREMENTS AND ASTM STANDARDS OF COMPATIBILITY OF FLOOR SLAB TREATMENTS (SEALERS, CURING AGENTS, CUTBACK NEUTRALIZERS). 4. CARPET INSTALLATION ADHESIVE SHALL BE CERTIFIED BY CARPET MANUFACTURER TO BE COMPATIBLE AND RECOMMENDED FOR USE WITH SELECTED CARPET 5. INSTALLED CARPET TO MEET THE WARRANTY REQUIREMENTS OF ISD FOR SUCH PRODUCT 6. INSTALL CARPET TILE AND RUBBER BASE AS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 1. ACOUSTICAL CEILINGS SHALL MEET THE AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM), LATEST EDITION A654 - STANDARD SPEC: F !CATION F07-11 STEEL SHEET, ZINC -COATED (GALVANIZED) OR SI NC -I RON ALLOY-COA7E: E) GALVANNEALED,lBYTHE HOT -DIP PROCESS, C635 - STANDARD SPECIFICATION FOR THE MANUFACTURE, PERFORMANCE, AND TESTING OF METAL SUSPENSION SYSTEMS FOR ACCOUSTICAL TILE AND LAY -IN PANEL CEILINGS, C636 - STANDARD PRACTICE FOR INSTALLATION OF METAL CEILING SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY -IN PANELS, E84 -STANDARD TEST METHOD FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, AND E1264 - STANDARD CLASSIFICATION FOR ACOUSTICAL CEILING PRODUCTS. PRODUCTS SHALL ALSO MEET UL RATING. 2. SURFACE BURNING CHARACTERISTICS, TESTED PER ASTM E84 SHALL BE AS FOLLOWS: A. FLAME SPREAD: 25 OR LESS B. SMOKE DEVELOPED; 50 OR LESS 3. CEILING GRID TO BE INSTALLED FREE OF IRREGULARITIES AND LEVEL TO WITHIN g' INCHES IN 12FT, AND A MAXIMUM DEFLECTION OF 1/360 OF SPAN. 4. CEILING TILE TO BE 24"x24", COMPLYING WITH ASTM E1264, CLASS A. TYPE Ilk, FORM 2, SQUARE EDGED, NOMINAL THICKNESS OF 5 INCHES, AND WITH FACTORY APPLIED FINISH 5. HANGERS SHALL BE 12 GAGE ANNEALED STEEL WIRE, GALVANIZED & FIT ACOUSTICAL LAY -IN PANELS TO GRID ACCURATELY, WITHOUT DENTED, BROKEN, CRACKED, CHIPPED, OR SOILED SURFACES. A CUT PANEL SHALL BE SIZED THAT WILL NOT EXPOSED AN EDGE WHEN THE PANEL IS SLID TO THE OPPOSITE SIDE 7. FIT ACOUSTICAL LAY -IN PANELS ACCURATELY AROUND SURFACE MOUNTED AND STEM MOUNTED ELECTRICAL FIXTURE. ADEQUATELY SUPPORT TEES SUPPORTING LIGHT FIXTURES BY HANGER WIRES SO GRID IS LEVEL AFTER LIGHT FIXTURE INSTALLATION. PROVIDE A HANGER WIRE WITHIN 3 INCHES OF EACH RECESSED LAY -IN LIGHT FIXTURE CORNER. 8. INSTALL CEILING IN A MANNER SUCH THAT BORDERS AREAS ARE BALANCED TO AVOID ACOUSTICAL UNITS LESS THAN 1 UNIT WIDE. 2 9. REPLACE DIRTY OR DISCOLORED ACOUSTICAL PANEL SURFACES FOLLOWING :1 ERECTION AND LEAVE FREE FROM DEFECTS. REMOVE DAMAGED OR IMPROPERLY INSTALLED PANELS AND REPLACE. PAINTING 1. PERFORM WORK IN A THOROUGH AND PROFESSIONAL MANNER IN CONFORMANCE WITH ACCEPTED GOOD PRACTICES AND REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. 2. PROTECT FINISHED MATERIAL AND AREAS NOT TO BE PAINTED BY USING DROP CLOTHS, MASKING, OR OTHER ACCEPTABLE METHODS. PROVIDE ADEQUATE VENTILATION FOR PROPER DRYING OF SURFACES BEFORE AND AFTER PAINTING. COMPLY WITH MANUFACTURER'S SPECIFICATIONS FOR MINIMUM DRY FILM THICKNESS. MINIMUM FILM THICKNESS SHALL BE 5 MILS, UNLESS OTHERWISE RECOMMENDED BY PAINT MANUFACTURER 3. ALL EXISTING AND INTERIOR WALL SURFACES, AND WINDOW FRAMES AND NON -STONE FINISHED WINDOW SILLS SHALL RECEIVE NEW PAINT. 4. INTERIOR WALLS SURFACES SHALL BE: i. 1ST COAT ii. 2ND COAT iii. 3RD COAT SCHEDULES AS FOLLOWS: A. GYPSUM BOARD: i. LOW LUSTER ACRYLIC -ENAMEL: (NON ACOUSTIC TILE CEILING AND SOFFITS) - WITH INTERIOR GYPSUM BOARD PRIMER, AND 2 FINISHED COATS OF LOW LUSTER ACRYLIC ENAMEL ii. SEMI -GLOSS ARCRYLIC-ENAMEL FINISH, WITH INTERIOR GYPSUM BOARD PRIMER, AND 2 COATS OF INTERIOR SEMI -GLOSS ACRYLIC ENAMEL B. FERROUS METAL: 1). FULL GLOSS ACRYLIC ENAMEL - WITH INTERIOR FERROUS -METAL PRIMER, AND 2 COATS INTERIOR FULL -GLOSS ACRYLIC ENAMEL ii). SEMI -GLOSS ACRYLIC -ENAMEL - WITH INTERIOR FERROUS -METAL PRIMER, AND 2 COATS INTERIOR SEMI -GLOSS ACRYLIC ENAMEL 1. BEFORE BEGINNING WORK AT THE SITE, THROUGHOUT THE COURSE OF THE WORK, INSPECT AND VERIFY THE LOCATION & CONDITION OF EVERY ITEM AFFECTED BY THE WORK & REPORT DISCREPANCIES TO ARCHITECT BEFORE BEGINNING WORK. 2. DO NOT DRILL OR CUT EXISTING FLOOR JOISTS, BEAMS, COLUMNS, OR OTHER STRUCTURAL ELEMENTS OF EXISTING STRUCTURE TO REMAIN, 3. PROTECT EXISTING WORK NOT PART OF DEMOLITION TO REMAIN FROM DAMAGE:. 4. WHERE CUTTING OF EXISTING SURFACES OR REMOVAL OF EXISTING FINISHES 1,13 REQUIRED TO PERFORM THE WORK REPAIR THE SURFACE AND FINISH TO MATCH ADJACENT EXISTING SURFACES. 5. TO THE EXTENT POSSIBLE CAREFULLY REMOVE/DEMOLISH USING SMALL HAND TOOLS 6. CONTRACTOR SHALL REPAIR ALL DAMAGES TO BUILDING AS THE RESULT OF'DEMOLITION 7. CONTRACTOR SHALL PROVIDE DUST FILTERS IN RETURN AIR GRILLS BEFORE COMMENCING WORK AND REPLACE FILTERS AT AIR HANDLER UNITS WHEN CONSTRUCTION IS FINISHED, CONTRACTOR TO PROVIDE BARRICADE AT DOORS DURING CONSTRUCTION TO ELIMINATE DUST AT HALLWAYS. ALUMN. ALUMINUN", N.I.C. NOT IN CONTRACT APPROX. APPROXIMATELY N.T.S. NOT TO SCALE ADJ. ADJUSTABLE O.C. ON CENTER BLDG. BUILDING OPNG. OPENING q_ CENTERLINE O.D. OUTSIDE DIMENSION C.W.S. COLD WATER SUPPLY O.H. OVERHANG COL. COLUMN PK PK SURVEY NAIL CONC. CONCRETE PKG. PARKING C.O.S. CHECK ("'IN SITE P.T.W. PRESSURE TREATED WOOD C.M.U. CONCRETE MASONRY UNIT REINF. REINFORCEMENT COND. CONDUIT REQMT. REQUIREMENT CONT. CONTINUOUS R.O. ROUGH OPENING CFM 'CUBIC FEET PER MINUTE SCH. SCHEDULE DET. DETAIL SH. SHEET DIA. DIAMETER SPK. SPRINKLER DWG. DRAWING SP STATIC PRESSURE EXIST. EXISTING T & G TONGUE AND GROOVE EXP. EXPANSION T.B. TIE BEAM T.B.D. TO BE DETERMINED FIN. FL. FINISHED FLOOR THD. THREADED F F.F.E. FINISHED FLOOR ELEVATION T.O.B. TOP OF CONC. BEAM F. F. L. FINISHED FLOOR LEVEL T.O.S TOP OF CONIC. SLAB FIN. WALL FINISHED WALL TYP. TYPICAL F.D. FLOOR DRAIN U.O.N. UNLESS OTHERWISE NOTED G.C. GENERAL CONTRACTOR W/ WITH GALV, GALVANIZED WD. WOOD H3 HOSE B113B DERM DEPARTMENT OF ENVIRONMENTAL H.D.G HOT DIPPED GALVANIZED RESOURCES MANAGEMENT HGT. HEIGHT MDWASD MIAMI-DADE WATER AND SEWER DEPARTMENT I.D. INTERIOR DIMENSION DBD DEPARTMENT OF BUSINESS JT. JOINT DEVELOPMENT MANUR MANUFACTURER DPDR DEPARTMENT OF PLANNING, MAX. MAXIMUM DEVELOPMENT & REGULATION MTL. METAL GSA GENERAL SERVICE ADMINISTRATION M.S.L. MEAN SEA LEVEL V.C.T HEAVY DUTY VINYL COMPOSITE TILE MIN. MINIMUM RM# ROOM NUMBER N.G.V.D. NATIONAL GEODETIC P.M PROJECT MANAGER VERTICAL DATUM NOM, NOMINAL RCP REFLECTIVE CEILING PLAN N/A NOT APPLICABLE COOR COORDINATE ff'MLXW ii!lll DESCRIPTION X x _ v_ :X-03 ORIGIN PAGE DESTINATION PAGE DESCRIPTION ORIGIN PAGE DESTINATION PAGE DETAd'_,S 1262913 N yl NORTH ARROW CENTER LINE BREAK LflE SPACE/ROONI NAME 1--ol __ FD6 M06 GRASS ISLAND STORAGE AREA 2 ASPHALT PAVING RB03 rr RB02 LAND L, __ - __ __ -1 F 83 RB04 l J r -- a;-� LL- GRASS ISLAND RW5 CONC. i FW DEM --T F_ GRASS ISLAND CONC. GRASS DECK ASPHALT ISLAND F03 r PAVING FM GRAM F_ I I S5 _7 T_ ASPHALT rI PAVING GRASS ISLAND STORAGE AREA GRASS BLDG. F02 SUBJECT OF RENOVATION (6,000 SF, 1 STY CBS CONST.) EXISTING PARKING (TYP.) NYISO ARCHI'fEC'fURAL GROUP, INC. AA 002935 CHARLES C. 1VVARK0, AIA AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL CONSULTANT: PROJECT NAME AND LOCATION: LUCIE COUNTY TRAFFIC ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE. DESCRIPTION: DRAWING TITLE: GENERAL NOTES PROJECT PHASE: 10OX SUBMITTAL ISSUE DATE: 9/27/21 DRAWN BY: O.V. I REVIEWED BY: C.N. F"SR WOSK DER NUMBER: ---- EET NUMBER 1%1 BUILDING LOU"ATIO'N' PLAN_ 29 1. 24 INCHES X 24 INCHES. 2. COMPLYING WITH ASTM E1264, CLASS A, TYPE III, FORM 2, SQUARE EDGED. 3. NOMINAL THICKNESS: 5/8". 4. FINISH: FACTORY APPLIED, WASHABLE WHITE. 5. NON -DIRECTIONAL PANELS 6. SUSPENSION GRIDS: 2'X2' EXPOSED, MEETING ASTM C635 7. CARPET TILES OF TUFTED NYLON PILE ON SPONGE PLASTIC OR CUSHION BACKING. 8. FACE YARN: 100% SOLUTION DYED, TYPE 6 OR 6.6, NYLON FIBER, BRANDED, CONTINUOUS FILAMENT, SOIL HIDING, WITH A PERMANENT INTEGRAL (NOT COATED) STATIC CONTROL COMPONENT. 9. PILE THICKNESS: 0.070 TO 0.148 IN.; ASTM D6859. 10.FINISHED PILE YARN WEIGHT: MINIMUM 16 OZ/YD2. 11.PILE DENSITY: 4500 - 8000 OZ/YD3 12.SOIL / STAIN RESISTANCE LEVEL OF YARN: USE A STAIN INHIBITING FLUOROCHEMICAL APPLIED DURING (NOT AFTER) MANUFACTURE OF THE YARN, ATTAINING AT LEAST LEVEL 6 ON THE RED 40 STAIN SCALE; AATCC 175. '.joajlkWA# it . } � M , • ! i ! ., } � it � r *. : ! t !� ! ♦w. ! /" �. . ! • � •s►+� _� ♦r! •r . ! . � ♦. +r a. DRILLING AND TAPPING FOR SURFACE APPLIED HARDWARE SHALL BE DONE IN THE FIELD. li. LOCATE HARDWAREfir!"RECOMMENDED LOCATIONS FOR BUILDERS HHARDWARPUBLISHED BY ♦ 'L BUILDERHARDWAREASSOCIATION 2. BUTT (HINGE) REINFORCING: a. STEEL PLATE 3/16" THICK BY 1-1/4" MINIMUM TO 1-1/2" MAXIMUM BY 10 INCHES LONG, OFFSET AS REQUIRED TO HAVE FACES OF BUTTS FLUSH WITH DOORFRAME EDGE AND SECURED BY NOT LESS THAN 6 SPOT WELDS. D. JAMB ANCHORS: PROVIDE ACCORDING TO FRAME MANUFACTURER'S RECOMMENDATIONS FOR ATTACHMENT TO MASONRY WALLS, CONCRETE COLUMNS, AND METAL_ STUD SYSTEM AS SHOWN ON DRAWINGS. ! '.�. . I. x ♦..All l.. • .... ! • fir'.}' l.. ,r r ! �' 1 ♦ ! ♦ r F. SPREADERS: PROVIDE FRAMES WITH TEMPORARY TEEL SPREADER BARS TACK WELDED TO JAMBS TO MAINTAIN FULL RIGIDITY AND PROPER ALIGNMENT DURING INSTALLATION. &TOX 1. CLASSIFICATION: SDI GRADE III - MODEL 2,16 GAGE, SEAMLESS, AND STEEL STIFFENED WITH M-DCPS REQUIRED REINFORCEMENT AND AS SHOWN ON DRAWINGS. 2. DOORS SHALL HAVE MINIMUM 20 GAGE, CONTINUOUS ONE-PIECE, VERTICAL STEEL_ STIFFENERS SPACED NOT TO EXCEED 6 INCHES APART AND WELDED AT 6 INCHES ON CENTER TO FACE SKIN. 3. LOCK RAIL SHALL BE ONE-PIECE, FULL HEIGHT MINIMUM 16 GAGE CHAIMNEL, 4. HINGE RAIL REINFORCEMENT MANUFACTURER'S OPTION. 5. CYLINDRICAL LOCK REINFORCEMENT: MINIMUM 16 GAGE: STANDARD HARDWARE LOCK BOX. 6. EXIT DEVICE REINFORCEMENT: MINIMUM 14 GAGE CHANNEL OR BOX MINIMUM 16" LONG BY 3-1/2" WIDE. 7. ALL SPACES BETWEEN STIFFENERS SHALL BE INSULATED "vV TH FIBERGLASS OR MINERAL INSULATION. 8. DOOR CLOSER REINFORCEMENT SHALL BE MINIMUM 12 GAGE CHANNEL OR BOX, WELDED TO TOP CHANNEL. BOTTOM OF REINFORCEMENT SHALL BE A MINIMUM OF 5-3/4" FROM TOP OF DOOR, BY WIDTH OF DOOR. 1 ACCESS PANELS 1. SIZES AS SHOWN ON DRAWINGS OR REQUIRED Try PROVIDE SUFFICIENT ACCESS FOR THE PROPER OPERATION OF MAINTENANCE. MINIMUM SIZE SHALL BE 12 INCHES X 12 INCHES. 2. PROVIDE 14 GAGE STEEL DOOR WITH 16 GAGE S 7 EEL FRAME WITH BAKED ENAMEL PRIME COAT. 3. PROVIDE FIRE -RATED COMPONENTS AT FIRE RATED CONSTRUCTION. 4. FLUSH PANEL DOORS: FABRICATE FROM NOT LESS THAN 14-GAGE SHEET STEEL, WITH CONCEALED SPRING HINGES OR CONCEALED CONTINUOUS PIANO HINGE. FINISH AS NOTED ON DRAWINGS. STANDARDTEMPEREDGLASS: COMPLY WITH ASTM C1036 AND FURTHER PROCESSED ACCORDING TO ASTM C1048, KIND FT, WHICH HAS BEEN FULLY TEMPERED BY THE MANUFACTURE:R'S HORIZOPITAL ?IIROCESS. , GYPSUM WALLBOARD: 1. GYPSUM BOARD: ASTM C36, TAPERED EDGE, 5/8" THICK X 48 INCHES WIDE X LONGEST STOCK LENGTH, 2, FASTENERS: TYPE S BUGLE HEAD BY USG OR ACCEPTED EQUIVALENT, WITH LENGTHS AS SPECIFIED BY MANUFACTURER., 3. JOINT TREATMENT: REINFORCING TAPE, TAPING, OR EMBEDDING AND TOPPING MATERIALS AS RECOMMENDED AND MANUFACTURED BY GYPSUM WALLBOARD MANUFACTURER, 4. ACCESSORIES: 1. ALL PAINT MATERIALS. ! IN THE LATESTOF PRODUCT AND SHALL BE FROM A SINGLE MANUFACTURER FOR 2ALL MATERIALS, PREPARATION AND WORKMANSHIP SHALL CONFORM TO THE STANDARDS CONTAINED IN THE LATEST EDITION OF THE MASTER PAINTERS INSTITUTE (MIP�). 3. PAINT SYSTEMS USED FORPROJECTSHALL* BY THE +.INTING SUB -CONTRACTOR WITH COLLABORATION FROM PAINT MANUFACTURER AND SHAILL MEET ALL. THE PERFORMANCE CRITERIA AND WARRANTY REQUIREMENTS SPECIFIED IN THIS DOCUMENT. 4. PRIMERS, r■ UNDERCOATS, INTERMEDIATE !1 AND FINISH COATS: MATERIALS ••. SAME MANUFACTURER xyJ..rWHEN SUCH MATERIALS .:w• ARE APPLIED ON ♦ME SURFACE. COLORS5. COLOR SELECTION MADE BY OWNER OR A/E'IS TO DETERMINE BASIC COLOR REQUIRED FOR SURFACE. 6. SELECT FROM APPROVED MANUFACTURER'S COLOR FAN. 7. IF COLOR IS NOT LISTED FOR A SPECIFIC AREA OR ITEM, CONTRACTOR IS NOT RELIEVED OF RESPONSIBILITY FOR PROVIDING COLORS SUBSEQUENTLY SELECTED. 8. COLORS WITH SAME DESIGNATION BUT PRODUCED FROM TWO OR MORE SOURCES SHALL MATCH WHEN VIEWED FROM DISTANCE OF 24 INCHES OR MORE. 9. FINAL APPLICATION OF COLORS SHALL MATCH MOCK-UP APPROVED BY OWNER. 1. FIRE EXTINGUISHERS: DRY CHEMICAL AND ABC TYPE MULTI --PURPOSE WITH FOG NOZZLE ATTACHED TO A HOSE. 2. TYPES OF FIRE EXTINGUISHERS: 1) ::LASS C FIRE AREAS. 3. LOW HAZARD AREAS: 2A-10BC. 1) HALLWAYS AND REMAINING ROOMS. 2) CLASS A OR B FIRE AREAS. 4. FOR USE WHERE® EXTINGUISHER CABINETS ARE SPECIFIED (LOW HAZARD AREAS): 1. THE EXTINGUISHER SHALL BE A MULTI I �URPOSE, DRY CHEMICAL STORED PRESSURE TYPE WITH A CORROSION -RESISTANT REUSA LE METAL YL NDER 2'­F 5-POUND CAPACITY WITH A DURABLE 3THE EXTINGUISHER SHALL HAVE A VALVE LOCKING PIN WITH A PULL RING AT ONE END OF STAINLESS STEEL OR HARD ALUMINUM AND SHALL NOT BE RErI )VABLE WITHOUT BREAKING THE METAL R PLASTIC & THE EXTINGUISHER SHALL NOT EXCEED AN OVERALL HEIGHT OF 19-1/4", A CYLINDER DIAMETER OF 5-3/4" AND AN OVERALL WIDTH OF 9 INCHES. EACH EXTINGUISHER SHALL HAVE A SECURELY ATTACHED NAMEPLATE OR BAND BEARING COMPLETE OPERATING INSTRUCTIONS, THE NAME OR MARK OF UNDERWRITERS LABORATORIES, A CONTROL NUMBER, THE WORDS "LISTED", "DRY CHEMICAL FIRE EXTINGUISHER", "CLASSIFICATION 2A-IOBC", AND THE MANUFACTURER'S NAME AND EXTINGUISHER MODEL NUMBER. 1. EACH TYPE OF EXTINGUISHER SHALL ARRIVE ON SITE, READY FOR USE, CHARGED WITH NON -TOXIC, MULTI -PURPOSE, SILICONI-TREATED AMMONIUM PHOSPHATE TYPE DRY CHEMICALAND DRY NITROGEN } 2. CABINET DOOR: PANEL WITH FULL TEMPERED GLASS, CATCH, AND NO LOCK. 4. EACH 2A-10BC EXTINGUISHER SHALL AI_3O BE AT LEAST THE EQUAL OF THE GENERAL FIRE EXTINGUISHER CORP. EXTINGUISHER MODEL TCP-5JH FITTED WITH A DISCHARGE HOSE AND PROVIDED WITH A MODEL MVCP-5 HANGING BRACKET. NYAKO C I'I , TURAL GROUP, INC. AA 002935 CHARLES 0. NYARKO, AiA AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 1 FAX:. (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: CONSULTANT: PROJECT NAME AND LOCATION: ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: PRODUCT NOTES PROJECT PHASE: 100Z SUBMITTAL ISSUE DATE: 9/27/21 - DRAWN BY: A O.V. REVIEWED BY: C.N. WORK ORDER NUMBER: -- -- SHEET NUMBER T EXIST. /--CONCRETE 00 On 50T, 111,1112' me EAMI 0 2' 4' CONTRACTOR SHALL INSPECT EXISTING SPACE. EXISTING SPACE HAS ELECTRICAL CONDUITS, SWITCHES, WATER SUPPLY PIPING, ELECTRICAL PANEL, JUNCTION BOXES, CEILING LIGHT FIXTURES MOUNTED UNDER EXISTING ROOF TRUSSES, AND OTHER ELECTRICAL FIXTURES AND CONDUITS. CONTRACTOR TO INSPECT EXISTING ITEMS, COORDINATE WITH IMPROVEMENT PLAN AND REMOVE ALL ITEMS NOT INTENDED TO REMAIN OR REUSE IN NEW IMPROVEMENT SPACE. ELECTRICAL CONDUITS ON WALL AND CEILING TO BE RE —USED TO BE CONCEALED UNDER G.W.B. AND IN BETWEEN FURRING STRIPS ON WALL OR UNDER CEILING. PICTURE 1 PICTURE 3 (TYP.) =—' ®=- PICTURE 2 Ewratillmol • EXISTING CONDNITION -PICTURES D"EMU"'I'LITION NOTES TAGS DESCRIPTION --- REMARKS REMOVE ELECTRICAL DEVICES AND EQUIPMENT ON WALL AFFECTED BY NEW WORK. REFER TO IMPROVEMENT PLANS. 2 REMOVE CAREFULLY EXITING EXIT/EMERGENC°Y LIGHT 3 > REMOVE RECEPTACLE AND CONDUIT BACK TO IDANE:L 04 REMOVE FIRE EXTINGUISHER AND PUT IT BACK AFTER NEW FINISHING r- INSTALLATION ---- CUT ABANDONED PLUMBING PIPE FROM OUTSIDE A.NJ CAP. PATCH/REPAIR 5 EXIST. HOLE IN WALL BEFORE NEW FINISHING INSTALLATION. ACTIVE _ PLUMBING PIPE TO REMAIN. 6� REMOVE EXISTING DOOR AND FRAME. MODIFY EXISTING OPENING FOR NEW DOOR AS NECESSARY 7 REMOVE SURFACE MOUNTED CONDUITS FEEDING RECEPTACLES -- - - - c� - - - -- — - - REMOVE CAREFULLY EXISTING ELECTRICAL PANEL AND PUT IT BACK AT COORDINATE WITH IMPRO. PLANS SAME LOCATION AFTER NEW FINISHING PREPARE SURFACE OF EXISTING MASONRY W Al_L AND PATCH/REPAIR (9-i/ ANY DAMAGE IN WALL TO RECEIVE NEW FINISH NG. (REF. TO IMPROVEMENT PLAN) PREPARE SURFACE OF EXISTING FRAME WOOD WALL a+]TH PLYWOOD FINISH AND Q PATCH/REPAIR ANY DAMAGE IN WALL TO RECEIVE NEV,1 FINISHING. (REF. TO IMPROVEMENT PLAN) �) EXISTING ROLLING DOOR TO REMAIN 2 EXISTING SINGLE DOOR TO REMAIN (13) EXISTING DOUBLE DOOR TO REMAIN 1 4 REMOVE AND DISCARD EXISTING SURFACE MOUNTED LIGHTING FIXTURE r�j jl EXIST. BLDG. SURFACE MOUNTED LIGHT FIXTURE TO REMAIN. REFER TO ELECT. PLANS 1 bf MODIFY EXISTING OPENING FOR A NEW DOORAS NECESSARY TAG O DE-MOLITION NOTES PICTURE TARGET DEVICES i i I i DOUBLE RECEPTACLE LIGHT SWITCH EXIT SIGN WITH EMERGENCY 1_11GHTS ^ k' ;F.E; FIRE EXTINGUISHER WALL LEGEND EXIST. INTERIOR FRAME WOOD PARTITION WITH PLYWOOD FINISH T ! � I 11] EXIST. EXTERIOR MASO`i,IRY WALL J'7 0 L AA 002935 CHARLES O. NVARK0, AIA AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: CONSULTANT: PROJECT NAME AND LOCATION: OFFICES 7, ' Al ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: AIT , TITLE: FLOOR t ECT PFIASE: 100X SUBMITTAL 1 AL DATE~ 9/27/21 N BY: O.V. REVIEWED BY: C.N. K ORDER NUMBER: — ---- SHEET NUMBER Ll 1__A2 NIL tj EXIST. oll PARKING -C ATCH BASIN C.U. 7Ow CONC. P EXIST. PARKING Vol EXIST. � ELEC.PANEL � EXISTING GWATER CATCH COOLER- BASIN PROPOSED WORK AREA - 1 EXISTING ACTIVE PLUMBING .� PIPE TO REMAIN ~- �EXIST PARKING UTRIPING /TY9.\ � COVER L & Ld EXISTING AREA (N.I.C. ''D FIT RAC 18 SF B0S[ ^� /--C J� punmmc P r-% 0-% P S E r-% I IL A P r% AO"%� IL I E- IL L U M H(.)V -MAEN' T K` E%T" tr ---%'L' -A N . . . . O 2 4 8 1G 1 /Fl"--1' (l`' ��[`4| � /`' _ _� ~`''`�� BACKING FOR WALL - HUNG FIXTURE / FORNITURE NOTE%'.'): STEEL STUD SUPPORTING WALL HUNG PLUMBING FIXTURES & WALL CABINETS SHALL BE DOUBLED OR NOT LESS THAN 20GA. & SECURELY FASTENED TO NOT LESS THAN TWO STUDS. STEEL STUD SHALL BE PROVIDED TO WITHSTAND 200 LBS FORCE IN ALL DIRECTIONS. (OR SUPPORTS BE PROVIDED AS PER FIXTURE MANUFACTURES REQUIREMENTS) IF MFR REQUIREMENT IS MORE STIRINGENT FLAME SPREAD AND SMOKE DENSITY NOTES: 1. WALL AND CEILING FINISHES TO HAVE A FLAME -SPREAD CLASSIFICATION OF NOT GRATER THAN 200 2. WALL AND CEILING FINISHES TO HAVE A SMOKE -DEVELOPED INDEX OF NOT GRATER THAN 450 3, TEST TO BE MADE IN ACCORDANCE-WASTM-E84 PLUMBING FIXTURE COUNT OCCUPANCY CLASSIFICATION: BUSINESS TOTAL OCCIJ--IANCY: 15 PEOPLE FIXTURE TYPE CODE RQMT AS PER WATER CLOSET (AND URINALS) LAVATORIES (MEN & WOMEN) BATHTUB SHOWEIRS DRINKING FOUNTAIN JANITORIAL SINK REQUIRED NIA, 1 Ol NOTE: FOR BUSINESS AND MERCANTILE CLASSIFICATIONS WITH AN OCCUPANT LOAD OF 15 OR FEWER, SERVICE SINKS SHALL NOT BE REQUIRED. FLOOR OCCUPANCY LOAD ANA[-Y,9,. S: - TOTAL GROSS AREA OF EXISTING BUSINESS SPACE = 1,200 SF - OCCUPANCY LOAD IN BUSINESS AREA @ 150 SF PER PERSON = 1,200,1150 = 8 PEOPLE - TOTAL GROSS AREA OF EXIST. AND NEW WAREHOUSES SPACE = 3,255 SIF - OCCUPANCY LOAD IN WAREHOUSES AREA @ 500 SF PER PERSON = 3,255/500 = 7 PEOPLE - TOTAL OCCUPANCY ON FLOOR = 8 + 7 = 15 PEOPLE NOTE: OCCUPANCY LOAD ACCORDING TO F.B.C. 2020 SECTION 1004: OCCUPANCY, LOAD, TABLE 1004,5: MAXIMUM FLOOR ALLOWANCES PER OCCUPANT. THE INTENT OF IMPROVEMENT IS TO RENOVATE THE OPENED AND VACANT AREA OF BUILDING INTO THE NEW OFFICES OF THE TRAFFIC DEPARTMENT OF THE COUNTY OF PORT ST. LUC|E. AS INDICATED IN IMPROVEMENT PLAN THE RENOVATED SPACES SHALL CONSIST OF OFFICES, OPEN -SPACE WORK AREAS AND MECHANICAL STORAGE ROOM. REFER TO ALL SHEETS OF PLANS` INCLUDING BUT NOT LIMITED TO OTHER ARCHITECTURAL PLANS AND DETAILS, ELECTRICAL, AND MECHANICAL PLANS FOR OTHER INTENDED SCOPE OF IMPROVEMENT WORK. CONTRACTOR TO PROVIDE ALL MATERIAL EQUIPMENT AND LABOR FOR THE COMPLETION OF THE RENOVATION TO ACHIEVE THE REQUIRED IMPROVEMENT. TAG DESCRIPTION �REFER TO SHEET SCHEDULE A6.0) (D DOORS SCHEDULE F"::� WINDOW SCHEDULE NEW CUBICLE PARTITION NEW INTERIOR PARTITION: 5/8" QNB ON 3-5/8" MTL. STUD /20go\ FRAMING @ 16" O.C. AND PAINT. EXIST. INTERIOR FRAME WOOD PARTITION WITH PLYWOOD FINISH EXIST. EXTERIOR MASONRY WALL NVAIM0 ARCHITECTURAL GROUP, INC. AAou2san CHARLES 0.NYARK0, AIA A/r/5759 5931N\m1r3DRIVE, SUITE 2.M|AM!.rL33O1m TEL: (305)82O-3555 / FAX: (Do5)S20-321OEMAIL: CONSULTANT: PROJECT NAME AND LOCATION: a "T mwm , Lo malE ADDRESS: a1naWILL FEE ROAD, FORT PIERCE, FL 34982 nEvS|own: NO. DATE DESCRIPTION: DRAWING TITLE: PROPOSED OFFICES KEY PLAN ISSUE DATE: 9/27/21 )WORK ORDER NUMBER: ---- SHEET NUMBER Ajou -- -- - A.H.U.-2 A.H.U.-1 SEC.D A4,0 A8.0 - - EXIST. MECH./STORAGE ROOM co -�- 16' NEW OPENING THRU WALL FOR O/A INTAKE VENT. - - -C.0 COORDINATE WITH r' MECHANICAL PLANS — l oo EXIST. PARTITION WALL NEW POWER STRIP -3' A.F.F. (REF. TO ELEC, PLAN) 5' EXIST. PARTITION WALL 32'-411 1 1 2 b-) (TYP.) SEAL EXIST. SURFACE FLOOR MTL SHE ill L� (TYP.) 20 (TYP.) PROPOSED -- -- --- WORK AREA -1 161-2" --- - - __ _ --- 5 ( ' 101-1011 it - FF JE %7% ____ ______7 -i � C111 -- - -Y c� mot- F4 ul) 4 J Co EXI _ STING ACTIVE PLUMBING --- IL: 7 EXIST. SURFACE PIPE TO REMAIN 20-11 MOUNTED LIGHT 6 FIXTURE TO (TYP.) _ DET.D ' � 2'-411 REMAIN. (TYP.) ---__ -- --, 26' -2" 6 -_ -- - - F.E. ELEV.2 CU -----� -- EXIST. FIRE 6 EXTINGUISHER (TYP.) FRAME PARTITION --- C! GROUP - O EXT ■ - - WALL (TYP.) F8 C - ■ OFFICE M r01 - 2__. 20 0 �— ` (TYP.) (TYP.) ' _� I - - ' 2 - i-- FRAME PARTITION SEC.A WALL (TYP.) F1 f) - OFFICE -1 A4.0 A8.0 F1 OFFICE - 2 F1 Loll 03 (TYP.) (TYP.) 8 \� �h �\ (TYP.) - - � MI r — (TYF> --- ---- -- - --- — HALLWAY F1 F� - ;NEW MINI SPLIT } - - - SYSTEM ON WALL TYP.) (REF. TO MECH. PLAN) F2- -- -- ---- _ -- �� �> E - ONDENSER LINE �': -� F1 /l�, - - �� -- TO TERMINATE Q - _ L -w--� - -- 8 4�� ABOVE PAVEMENT - - _=- "- --- -- - - - - - (TYP.) - 1 IT RACK 12 9 , Yp �� C l -_ L _ , i --- -- U"i ROOM F3 F1 F3 F1 04 I I -_ (TYP .) _ -- � _. -_ (TYP. ) -- EXIST. C.U. TO REMAIN - -_ - — - --- i SEC. SEC.B - - C.U. OVER NEW CO C. AD BASE ,/ 1 ' EXISTING AREA N.I.Cm)/4.O A8.0 4.0 A8. ON EXIST. STALL PARKING LOT. - REFER TO MECH. PLAN) 41 '/ 'z C-1 D ET. 7 /V OTE: � O THE NEW C.U. WILL BE LOCATED IN THE SAME ,r - 1' 2' 611 A4.0 A9.0 — _ STALL PARKING LOT SPACE (No.7) WHERE THE -- — -- XISTING C.U. JS C RRENTLY LOC TED Co o , i o� Nor A.H.U.-3 CV, m `' - - O --- ---- -- - DET.8 N A6.0k-A - z 4„, �- PLAN -A All 1 k4.0 FURNITURE, EQUIPMENT AND ACCESSORIES SCHEDULE ITEM DESCRIPTION QTY. BASIS OF DESIGN MFR TAG OFFICE DESK. 60" X 72" MFR: NEWMARKET OFFICE F1 L SHAPE DESK WITH BOX/FILE 2 FURNITURE, BRAND: ICON PEDESTAL 60" X 72" L-SHAPE DESK WITH BOX/FILE PEDESTAL OFFICE DESK WITH MFR: MADISON LIQUIDATORS. CF DRAWERS. LAMINATED 2 BRAND: CHERRYMAN. WOOD. TYPE - 2 SERIES: AMBER. 71" X 84" - L SHAPE DESK MFR: DIGITAL BUYER,COM. VERTICAL 4-DRAWER 6 BRAND: HON. 4-DRAWER 26.5"W F3 METAL FILE CABINET X 18.25"D X 52"H LATERAL FILE CABINET, PART# 314CP F4 TACK BOARD 1 MFR: MASTERVISION. ENCLOSED BULLETIN BOARD 38"W X 47'H. MATERIAL: CORK. ZORO#: G7309605 MFR#: VT380101150 F5 PRODUCTION TABLES. 4 (INSTALLED BY CONTRACTOR) CCTV (CLOSED-CIRCUIT TV), F6 [SELECTED AND PURCH. BY 1 OWNER INSTALLED BY CONTR] F7 NOT USED MFR: DIGITAL BUYER.COM. Fg PRINTER STAND 2 BRAND: MAYLINE. MOBILE STEEL UTILITY STORAGE CABINET. DIM: 30"WX 21 "D X 26.5"H MFR: AVALON, BOTTOM -LOADING Fg BOTTLE FILLER 1 COLD AND HOT WATER COOLER. WATER COOLER DIM:12"W X 13T X 41"H MONITORING DESK. LAM, WOOD 94" X 30" FULL MODESTY DESK SHELL F 1 1 (MONITORING DESK), NEWMARKET (REF. TO SHEET A6.0 DET.D) OFFICE FURNITURE. BRAND: IOF F 11 NOT USED HORIZONTAL MFR: DIGITAL BUYER.COM. F1 4-DRAWER 12 BRAND: GLOBAL. 4-DRAWER METAL FILE CABINET 36"W X 18"D X 54"H LATERAL FILE CABINET. PART#9336P-4F1H MFR: JCWHITE ARCHITECTURAL F1 STANDARD OFFICE 10 INTERIOR PRODUCTS. MODEL: CHAIR VERY TASK CHAIR FOR OFFICE AND WORKSTATION F 1 NOT USED AHU-1 (REFER TO MECHANICAL PLAN) 1 AHU-2 F1 (REFER TO MECHANICAL PLAN) 1 F17 CUBICLE PARTITION -- MFR: JC WHITE ARCHITECTURAL INT. PRODUCTS. HAWORTH/COMPOSE ADAPTABLE WORKSURFACE WITH X-SERIES STORAGE NOTES: APPROVED SUBSTITUTION OF EQUAL OR SIMILAR PRODUCT FROM OTHER MANUFACTURE ALLOWED. FURNITURE DIMENSION NOTES: FOR FURNITURE AND EQIJIPMENT DIMENSION REFER TO FURNITURE AND EQUIPMENT DIMENSION IN SHEET SCHEDULE A6.0 TAG DESCRIPTION (REFER TO SHEET SCHEDULE A6.0) IMPROVEMENT NOTES (REFER TO THIS SHEET) F1 FURNITURE SCHEDULE (REFER TO THIS SHEET) O DOORS SCHEDULE 01 INTERIOR FINISH SCHEDULE & SIGNAGE SCHEDULE LEGEND NEW CUBICLE PARTITION NEW INTERIOR PARTITION: 5/8" GWB ON 3-5/8" MTL. STUD (20ga) FRAMING @ 16" O.C. EXIST. INTERIOR PARTITION WALL WITH PLYWOOD AND PAINT FINISH EXIST. EXTERIOR MASONRY WALL IMPROVEMENT NOTES TAGS DESCRIPTION REMARKS IN THE INTERIOR SIDE OF EXTERIOR WALL, PROVIDE METAL FURRING STRIPS @ 16" O/C, R-7.3 THERMAL INSULATION AND 5/8" G.W.B. AND PAINT EXIST. CONCRETE SLAB: CLEAN AND SEAL SURFACE. 3 UNDER EXIST. WOOD TRUSSES: PROVIDE NEW ATTIC SPACE THERMAL INSULATION (FIBERGLASS) WITH PAPER BACK. PROVIDE NEW 5/8" G.W.B. CEILING IN PROPOSED WORK AREAS AND MECH./STORAGE ROOM. PREPARE G.W.B. CEILING TO RECEIVE NEW SURFACE MOUNTED LIGHT FIXTURES. (REFER TO ELECTRICAL PLANS.) EXISTING ATTIC SPACE VENTILATION ❑5 NEW INTERIOR PARTITION WALL WITH 3-5/8" MTL STUDS (20GA) @ 16" O/C AND WITH 5/8" G.W.B. PROVIDE INTERMEDIATE BRACING AT MID -HEIGHT OF ALL NEW PARTITION WALLS EXCEEDING 8FT IN HEIGHT. COORDINATES THE LOCATIONS OF WALL MOUNTED FIXTURES/EQUIPMENTS AND PROVIDE SUPPORT BRACING WITH CHANNELS AT POINTS OF ATTACHMENTS. SUPPORT BRACING TO HAVE CAPACITY FOR 200LBS IN AL DIRECTIONS. PROVIDE 6" RUBBER BASE AT ALL WALLS - BOTH EXISTING AND NEW PROVIDE SOUND ATTENUATION BATT INSULATION IN ALL NEW STUD WALLS NEW SUSPENDED 2"X2" ACOUSTIC TILE CEILING WITH ALUMINUM GRID IN ENCLOSED OFFICE SPACES AND CORRIDOR BETWEEN OFFICES aPROVIDE NEW 4" CONCRETE SLAB BASE FOR NEW C.U. 1 O PROVIDE CARPET TILE IN NEW OFFICES AREA 1 1 PROVIDE 5/8" G.W.B. PAINTED OVER EXIST. PLYWOOD FINISH 1 2 NEW DUCTWORK FROM UNITS OVER EXIST. WOOD JOIST. PROVIDE INTERMEDIATE CHANNEL FASTENED BETWEEN EXIST, WOOD JOIST AT 16" O/C TO SUPPORT DUCTWORK AS NECESSARY. (REFER TO MECH. PLAN) 13 PROVIDE NEW O/A PENETRATION AND O/A INTAKE GRILL THRU MASONRY WALL TO RECEIVE NEW O/A DUCT FROM AHU. (REFER TO MECH. PLAN) 14 CONDENSER LINE TO TERMINATE 4" ABOVE PAVEMENT. 14.1 NEW REFRIGERANT LINES TO THE TOP OVER EXIST. WOOD JOIST THAT GOES OVER THE EXIST. CONC. BEAM TO OUTSIDE AND GOES DOWN THROUGH THE S. S. SHEET MTL TO THE C. U. REFER TO MECHANICAL PLAN) 15 16GA MTL STUD TV SUPPORT BRACING. PROVIDE BACKING AS REQUIRED. COORDINATE LOCATION WITH EQUIPMENT 1 6 INTERMEDIATE CHANNEL FASTENED BETWEEN EXIST. WOOD JOIST AT 48" O/C TO FASTEN MTL STUD RUNNER FRAME WALL 171 BOTTOM TRACK (20GA) W/ 3/16"0 X 1-1/4" POWER DRIVEN SCREWS @ 16" O/C 18 METAL STUD RUNNER FASTENED TO MTL CHANNEL 1 9 INTERMEDIATE BRACING AT WALLS HIGHER THAN 8'-0" A.F.F. 20 ROOM SIGNAGE (TYP.) REFER TO SIGNAGE SCHEDULE IN SHEET A6.0 21 REPLACE EXIST. THRESHOLD WITH NEW ALUMINUM THRESHOLD 1/2" MAX. HEIGHT. 22 NEW CONDENSER UNITS (REFER TO MECHANICAL PLAN) 23 SOFFIT OVER CORRIDOR WITH 3-516,, MTL CHANNEL 20GA MIN. FRAMING 16" O/C WITH 5/8" G.W.B. AND PAINT. NVARKO ARCHITECTURAL GROUP, INC. AA 002935 CHARLES O. NYARKO, AL4 AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: CONSULTANT: PROJECT ST. LUCIE COUNTY TRAFFIC OPERATIONS OFFICES ;14 Ll MT11 1 [11 � III ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: PLAN -A - FLOOR PLAN AREA PROJECT PHA E: 100Y. SUBMITTAL ISSUE DAT 9/27/21 DRAWN O.V. REVIEWED BY: C.N. WORK MER NUMBER: ---- 0 1' 2' +' n 114 - 0" ALE 1 I , EXIST, ELEC. PANEL TO REMAIN 80 EXIST. STRIPINGTALL (TYP.) NOTE: WIDTH OF THE CONCRETE SLAB SHOULD BE EXIST. ACCORDING TO THE WIDTH OF THE PARKING MASONRY WALL STALL, FROM STRIPE TO STRIPE. CONTRACTOR FIELD VERIFY DIMENSION BEFORE INSTALLATION. EXISTING CATCH BASIN CONC. PAD BASE STEEL TUBE BOLLARD.(TYP.) REFER TO DET.7 IN SH. A9.0---\ CONDENSER UNIT OVER NEW CONCRETE PAD ON EXIST. STALL PARKING LOT. (TYP.) (REFER TO MECH. PLAN) (SEC.E DET.8 A5.0 A9 0 7� rDET.8 A5.0 A6.0 A If 14 It 22 3 LL! DET.7 A570 A9.0 0 22 - r 6 i. NOTE: CONDENSER LINE TO TERMINATE 4" ABOVE PAVEMENT 16 MI 3'--MIN . A.H.U.-2 F1' 04 A.H.U.-1 _N Fl 0 1' 2' 1`0" SCALE EXIST. SURFACE MOUNTED LIGHT FIXTURE TO REMAIN. (TYP.) cy) F5 (TYP.) 501 CONCRETE A PAVING EXIST. FIRE EXTINGUISHER IN NEW LOCATION - 2 7 EXIST. SEALED SURFACE FLOOR 20 STEEL TUBE BOLLARD.(TYP.) REFER TO DET.6 IN SH, A5.1 FUTURE COMPRESSED AIR (N.I.C.) FUTURE CANOPY (N.I.C.)— NEW ELEC. DISCONNECTED FOR FUTURE COMPRESSOR (REFER TO ELEC. PLAN)— t-ro IF. E.1 WORKING TABLE (TYP.) 20 321-411 WAIII, (TYP.) Fl0 (TYP.) , YP.) 61 if L EQ - EQ Al _611 - - - - - - - - --- 31 EXIST. MASONRY WALL 71-311 -11 MTL SF i E L 0 F3 (TYP.) 31 FURNITURE, EQUIPMENT AND ACCESSORIES SCHEDULE ITEM DESCRIPTION CITY. BASIS OF DESIGN MFR TAG OFFICE DESK. 60" X 72" MFR: NEWMARKET OFFICE F L SHAPE DESK WITH BOX/FILE 2 FURNITURE. BRAND: ICON PEDESTAL 60" X 72" L-SHAPE DESK WITH BOX/FILE PEDESTAL OFFICE DESK WITH MFR: MADISON LIQUIDATORS. DRAWERS. LAMINATED 2 BRAND:CHERRYMAN. WOOD. TYPE - 2 SERIES: AMBER.71"X 84" - L SHAPE DESK 6 MFR: DIGITAL BUYER.COM. VERTICAL 4-DRAWER BRAND: HON. 4-DRAWER 26.5"W F3 METAL FILE CABINET X 18.25"D X 52"H LATERAL FILE CABINET. PART# 314CP MFR: MASTERVISION. ENCLOSED TACK BOARD I BULLETIN BOARD 38"W X 47"H. MATERIAL: CORK. ZORO#: G7309605 MFR#: VT380101150 CFj5_ PRODUCTION TABLES, 4 (INSTALLED BY CONTRACTOR) CCTV (CLOSED-CIRCUIT TV). F6 [SELECTED AND PURCH, BY OWNER INSTALLED BY CONTR.] F7 NOT USED MFR: DIGITAL BUYER.COM. PRINTER STAND 2 BRAND: MAYUNE. MOBILE STEEL UTILITY STORAGE CABINET. DIM: 30"WX 21"D X 26,5"H BOTTLE FILLER MFR: AVALON. BOTTOM -LOADING WATER COOLER COLD AND HOT WATER COOLER. DIM: 12"W X 13"D X 41 "H MONITORING DESK. LAM. WOOD 94" X 30" FULL MODESTY DESK SHELL _SK). (MONITORING DE NEWMARKET (REF. TO SHEET A6.0 DET.D) OFFICE FURNITURE, BRAND: IOF NOT USED HORIZONTAL MFR: DIGITAL BUYER.COM. (F 1) 4-DRAWER 12 BRAND: GLOBAL. 4-DRAWER METAL FILE CABINET 36"W X 18"D X 54"H LATERAL FILE CABINET, PART# 9336P-4F1 H MFR: JCWHITE ARCHITECTURAL STANDARD OFFICE 10 INTERIOR PRODUCTS. MODEL: CHAIR VERY TASK CHAIR FOR OFFICE AND WORKSTATION NOT USED AHU-1 (REFER TO MECHANICAL PLAN) oFlAHU-2 (REFER TO MECHANICAL PLAN) CUBICLE PARTITION MFR: JC WHITE ARCHITECTURAL INT. PRODUCTS. HAVIORTHICOMPOSE ADAPTABLE WORKSURPACE WITH X-SERIES STORAGE NOTES: APPROVED SUBSTITUTION OF EQUAL OR SIMILAR PRODUCT FROM OTHER MANUFACTURE ALLOWED. FURNITURE DIMENSION NOTES: FOR FURNITURE ANC' EQUIPMENT DIMENSION REFER TO FURNITURE AND EQUIPMENT DIMENSION IN SHEET SCHEDULE A6.0 TAG DESCRIPTION (REFER TO SHEET SCHEDULE A6.0) IMPROVEMENT NOTES (REFER TO THIS SHEET) FURNITURE SCHEDULE (REFER TO THIS SHEET) O DOORS SCHEDULE 0=1 INTERIOR FINISH SCHEDULE & SIGNAGE SCHEDULE LEGEND NEW CUBICLE PARTITION NEW INTERIOR PARTITION: 5/8" GWB ON 3-5/8" MTL. STUD (20go) FRAMING @ 16" O.C. EXIST. INTERIOR PARTITION WALL WITH PLYWOOD AND PAINT FINISH EXIST. EXTERIOR MASONRY WALL IMPROVEMENTNOTIES TAGS DESCRIPTION REMARKS I IN THE INTERIOR SIDE OF EXTERIOR WALL, PROVIDE MEITAL FURRING STRIPS @ 16" O/C, R-7.3 THERMAL INSULJkTION AND 5/8" G.W.B. AND PAINT EXIST. CONCRETE SLAB: CLEAN AND SEAL SURFACE. UNDER EXIST. WOOD TRUSSES: PROVIDE NEW ATTIC SPACE THERMAL INSULATION (FIBERGLASS) WITH PAPER BACK. PROVIDE NEW 5/8" G.W 13. CEIING IN PROPOSED WORK AREAS AND MECRISTORAGE ROOM. PREPARE G.W.B. CEIINGTO RECEIVE NEW SURFACE MOUNTED LIGHT FIXTURES. (REFER TO ELECTRICAL PLANS.) EXISTING ATTIC SPACE VENTILATION I-E NEW INTERIOR PARTITION WALL WITH 3-5/8" MTL STUDS (0GA) @ 16" O/C AND WITH 5/8" G.W.B. PROVIDE INTERMEDIATE BRACING AT MID -HEIGHT OF ALL NEW PARTITION WALLS EXCEEDING 8FT IN HEIGHT. COORDINATES THE LOCATIONS OF WALL MOUNTED FIXTURES/EQUIPMENTS AND PROVIDE SUPPORT BRACING WITH CHANNELS AT POINTS OF ATTACHMENTS. SUPPORT BRACING TO HAVE CAPACITY FOR 200LBS IN AL DIRECTIONS. 1 [�6] PROVIDE 6" RUBBER BASE AT ALL WALLS - BOTH EXISTING AND NEW PROVIDE SOUND ATTENUATION BATT INSULATION IN ALL. NEW STUD WALLS I NEW SUSPENDED 2"X2" ACOUSTIC TILE CEILING WITH ALUMINUM GRID IN ENCLOSED OFFICE SPACES AND CORRIDORBIETWEEN OFFICES L�O PROVIDE NEW 4" CONCRETE SLAB BASE FOR NEW C.U. El PROVIDE CARPET TILE IN NEW OFFICES AREA PROVIDE 5/8" G.W.B. PAINTED OVER EXIST. PL'y"WOOD FINISH ENEW 12 DJCTWi _yRK FROM UNITS OVER EXIST.WOOD JOIS7: PROVIDE INTERMEDIATE i CHANNEL FASTENED BETWEEN EXIST, WOOD JOIST AT I E" O/C TO SUPPORT DUCTWORK i ! AS NECESSARY, (REFER TO MECH, PLAN) 13 PROVIDE NEW O/A PENETRATION AND O/A INTAKE GRILL THRUI: MASONRY WALL TO RECEIVE NEW O/A DUCT FROM AHU. (REFI-R TO MECH. PLAN) LlTOCTERMINATE OND�� 4" ABOVE PAVEMENT. I .' [4 NEW REFRIGERANT LINES TO THE TOP OVER EXIST. WOOD JOIST THAT GOES OVER THE S EXI 'T CONC. BEAM TO OUTSIDE AND GOES DOWN THROUGH THE& S. SHEET MTL TO TH E C. U. (REFER TO MECHANICAL PLAN) 16GA MTL STUD TV SUPPORT BRACING. PROVIDE BACKING AS REQUIRED. COORDINATE LOCATION WITH EQUIPMENT 16 INTERMEDIATE CHANNEL FASTENED BETWEEN EXIST. WOOD JOIST AT 48" O/C TO FASTEN MTL STUD RUNNER FRAME WALL 117BOTTOM TRACK (20GA) Wl 3/16"0 X 1-1/4" POWER DRIVEN SCREWS @_ 16" O/C METAL STUD RUNNER FASTENED TO MTL CHANNEL 1 19 INTERMEDIATE BRACING AT WALLS HIGHER THAN 8'-0" A.F.F. 20 ROOM SIGNAGE (TYP.) REFER TO SIGNAGE SCHEDULE IN SHEET A6.0 21 REPLACE EXIST. THRESHOLD WITH NEW ALUMINUM THRESHOLD 1/2" MAX. HEIGHT, 22 NEW CONDENSER UNITS (REFER TO MECHANICAL PLAN) Di3 SOFFIT OVER CORRIDOR WITH 3-5/8" MTL CHANNEL 20GA MIN. FRAMING 16" O/C WITH 5/8" G.W.B, AND PAINT. NV ARCHITF,CTURAL GROUP, INC. AA 002935 CHARLES 0. NYARK0, AIA AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com CONSULTANT: PROJECT NAME AND LOCATION: U R E AM 0 m w bTl LE EGIE DIVA i I$] ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: PLAN-B - FLOOR PLAN AREA PROJECT PHASE loox SUBMITTAL ISSUE DAj% 9/27/21 DRAWN 4$ O.V. REVIEWED BY: C.N. WO RIDER NUMBER: ---- At S14VT NUMBER -- _ - - - -- - - DET.6 , I INTERIOR FRAME WALL: 5/8" G.W.B. 5LB FIRE �— ON 3-5/8" METAL EXTINGUISHER 1 �� A6.0 A9.0) STUD 20 a FRAMING 16" O.C. & PAINT ��-/6 ,\ METAL TUB DOOR STOP W/MOUNTING SCREW NOTE: INSTALLATION SHOP DRAWINGS REQUIRED. THE CONTRACTOR IS TO FIELD VERIFY ALL DIMENSION SCALE :1-1/2'-1'-0' SEMI -RECESSED FIRE EXTINGUISHER DETAIL PLAN 6 2' " f -- NEW FRAME WALL WITH 3-5/8" MTL STUD (TYP.)- HARDWOOD CAP ON SILL OF OPENING 0o 3-5/8" MTL STUDI'i FRAME KNEE WALL'i WITH 5/8" G.W.B. AND PAINT i co SCALE :1/2'=1'-0" ATTACHMENT SCREW METAL STUD FRAME 2 2" RT SHOWN HINGE W/MOUNTING SCREW METAL DOOR PULL HANDLE DET.0 A6.01--- KNEE WALL W/MONITORING DESK TAG DESCRIPTION (REFER TO FURNITURE SCHEDULE AT A4.0 & A5.0) F1 FURNITURE SCHEDULE FURNITURE AND EQUIPMENT DIMENSION co N Fo Q0 N'' I 5' OFFICE DESK. 60" X 72" L SHAPE DESK WITH BOX/FILE PEDESTAL F 1 9'-1 11 i- - --- -- 94 ----- - - - - M MONITORING DESK. LAMINATED WOOD F1 f 64,� 2'-211 04 OFFICE DESK 71" X 84° VERTICAL METAL L SHAPE DESK WITH DRAWERS F2 FILE CABINET - TYPE 1 F3 - 3� - x co - -- BOTTLE FILLER WATER COOLER HORIZONTAL METAL F9 FILE CABINET - TYPE 2 F 1 NOTES: THE DIMENSIONS ARE ACCORDING TO THE STANDARD DIMENSIONS OF FURNITURE AND EQUIPMENT ON THE MARKET. THE OWNER WILL SELECT AND PURCHASE FURNITURE AND EQUIPMENT ACCORDING TO THESE DIMENSIONS. EXIST. WOOD JOIST (TYP. EXIST. ATTIC SPACE VENTILATION EXIST. Y2" PLYWOOD WITH MTL LATH AND STUCCO — SEALANT APPLIED IN THE PERIMETER BETWEEN THE PLYWOOD AND THE S.S. SHEET METAL REFRIGERANT LINES SHEET METAL AND SEALANT TO ENCLOSE BOTTOM AND TOP CHASE .YY�1�'k�x` Xx X z xz I O Of °� > ` m w -- co i NEW S.S. SHEET METAL ENCLOSURE OF REFRIGERANT PIPE ALONG WALL )/4" 0 X 1 Y" DRIVE PINS @ 12" O/C EXIST. EXTERIOR WALL EXIST. CONIC. BEAM TOP SHEET METAL PLATE SEAL EXIST. CONC. BEAM BOTTOM Q 10'-10" HEIGHT NEW S.S. SHEET METAL ENCLOSURE OF REFRIGERANT PIPE ALONG WALL EXIST, EXTERIOR MASONRY WALL FASTEN SHEET MTL ENCLOSURE Ya" 0 X 1-Y4" DRIVE PINS @ 12" O/C CONCRETE PAVING LEVEL SIGNAGE SCHEDULE TAG NUMBER NAME NUMBERS OTY. REMARKS 01 GROUP OFFICE 01 1 02 OFFICE -1 02 1 03 OFFICE - 2 03 1 04 IT RACK ROOM 04 1 05 EXIST. MECH/STORAGE ROOM 05 1 06 PROPOSED WORK AREA -1 06 1 07 PROPOSED WORK AREA - 2 0 1 NOTE: FINAL DETERMINATION OF ROOM SIGN NAME TO BE MADE BY OWNER. NEW SIGNAGE NOTE- NEW SIGNAGE SHALL BE INSTALLED TO COMPLY WITH SECTION 703 OF FLORIDA ACCESSIBILITY CODE CHAPTER 7 FINISH FLOOR I SIGNAGE 181# TYPICAL SIGN HEIGHT A.F.F. DETAIL SCALE 3/8"=1'-0n IAIC`I II ATIlIAI IVIL I/'�L JIVV TYPICAL DOOR JAMB /HEADER DETAIL SCALE 3'=1'-0" INTERIOR FINISH SCHEDULE ROOM FLOOR BASE WALL CEILING REMARKS ck- w m DESCRIPTION W v m z L` 4 a J Ii C) w m w Z CLo Q¢ VCD O �I � N o O J m¢wCD w Z Z �-� m.- � I =O ¢ x c .q z -3:: �- U F- 01 GROUP OFFICE 0 0 0 0 02 OFFICE - 1 0 0 0 0 03 OFFICE - 2 0 0 0 0 04 RACK ROOM 0 0 0 0 05 EXIST. MECH./STORAGE ROOM O O O O O6 PROPOSED WORK AREA - 1 O O O O 07 PROPOSED WORK AREA - 2 O O O 1 O - PAINT ON ALL SURFACES TO BE PAINTED SHALL BE PRIMER COAT AND TWO FINISHED COATS. COLOR SELECTION BY ARCHITECT & OWNER DOOR SCHEDULE TAG TYPE OTY. PANEL SIZE DESCRIPTION THRESHOLD HARDWARE �1 1 1 3' X 7' 3/811 STORAGE ROOM TYPE 1 3 3' X 7' OFFICE TYPE METAL HIGH ALUM. (�3 2 1 6' X 7' PASSAGEWAY LOCK SET TYPE WITH AUTOMATIC FLUSH BOLT EACH LEAVE A 1 1 3' X 7' STORAGE ROOM TYPE 5 0 2 1 EXIST. DBL. EXISTING HARDWARE TO REMAIN. DOOR. EXISTING REPLACE EXIST. SGL. Q 1 1 DOOR. METAL DOOR TO W/NEW 3/8" ALUM. RETROFIT EXISTING DOOR WITH PANIC HARDWARE. COORDINATE EXIST. SGL. 0 1 1 R. REMAIN SUPPLIER __ 2 EXIST. ROLL. J DOOR. NOTE: PAINT ALL DOORS USING PAINT FOR METAL DOOR. COORDINATE WITH PAINT SUPPLIER T-4" 2 3' /nl� f� DOOR Nlli�il �� I � AME TYPE:1 NEW DOOR TYPES 4. 6'-4" 016 NYARKO ARCHITECTURAL GROUP, INC. AA 002935 CHARLES 0. NYARKO, A/A AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: CONSULTANT; PROJECT NAME AND LOCATION: ST. LUCIE ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: SCHEDULES PROJECT PHASE: 10OX SUBMITTAL ISSUE DATE: 9/27/21 DRAWN BY: O.V. REVIEWED BY: C.N. WORK ORDER NUMBER: ---- SHEET NUMBER ELEvA-nON VIEW S.S. SHEET METAL DETAIL SCALE :1/2"-1'-O" � • 1 4 EXIST. CONC. BEAM EXIST. CONC. BLOCK WALL W/STUCCO— EXIST. CONC. SLAB (TYP.) - EXIST, FOOTING (TYP.) - NEW HARD CEILING HEIGHT NEW ACOUSTICAL CEILING HEIGHT �i EXIST. DOOR BEYOND CORRIDOR AREA DET.2 A8.0 A9.0 16GA MTL STUD TV SUPPORT BRACING _ 1 I GRoL7P L ___T � I OFFICE AREA mmoo mommoo DET.3 F1 F1 F6 A8.0 A9.0 SECTION A SCALE :1/4'=1'-0' AIR HANDLE UNIT SECTION SCALE: 3/8" = T-0' PROPOSED WORK AREA - 1 OFFICE-01 0 II i J 4 DRAWER MTL CABINET BEHIND WALL (TYP.) — ELEVATION 2 SCALE :1/4"=1'-O' OFFICE-1 AREA SEC.D 4.0 A8.0 20 (TYP.) I, OFFICE-02 -- �nI W ELEV.2 UAl. 7 SEC.A A4. 01 A8.0 OFFICE-2 AREA 3 ALE-Va -ra CORRIDOR SECTION BETWEEN OFFICES 0 MECH. PLAN) EXIST. E-VIC'r DnnC fll vUlnnn I-1kilc`I I EXIST. ROOF EXIST. CONC. BEAM S.S. SHEET MTL DETAIL. REFER TO SHEET A6.0 DET.8 DUCT 1. PLAN) OUTSIDE AREA PROVIDE NEW PENETRATION THRU MASONRY WALL TO RECEIVE NEW CONDENSER LINE EXIST. CONC. PAVING PARKING XIST, FOOTING NEW ACOUE FFL i innv�rvvv uni A8.0 A9.0 SECTION B SCALE 1/4"-1'-O" ELEVATION 1 rELEV.'l"" SCALE :1/4'-1'-0' A4.0 A8.0 SEC.0 A-4 ,01 A8.0 TAG DESCRIPTION aIMPROVEMENT NOTES WINDOW SCHEDULE (REF. TO SHEET SCHEDULE A6.0) FURNITURE SCHEDULE F1 (REFER TO FURNITURE, EQUIPMENT AND ACCESSORY SCHEDULE IN SHEET A4.0 AND A5.0) IMPROVEMENT NOTES TAGS DESCRIPTION REMARKS aIN THE INTERIOR SIDE OF EXTERIOR WALL, PROVIDE METAL FURRING STRIPS @ 16" O/C, R-7.3 THERMAL INSULATION AND 5/8" G.W.B. AND PAINT EXIST. CONCRETE SLAB: CLEAN AND SEAL SURFACE. UNDER EXIST. WOOD TRUSSES: PROVIDE NEW ATTIC SPACE THERMAL INSULATION (FIBERGLASS) WITH PAPER BACK. PROVIDE NEW 5/8" G.W.B. CEILING IN PROPOSED WORK AREAS AND MECH./STORAGE ROOM. PREPARE G.W.B. CEILING TO RECEIVE NEW SURFACE MOUNTED LIGHT FIXTURES. (REFER TO ELECTRICAL PLANS.) HlEXISTING ATTIC SPACE VENTILATION NEW INTERIOR PARTITION WALL WITH 3-5/8' MTL STUDS (20GA) @ 16" O/C AND WITH 5/8" G.W.B. PROVIDE INTERMEDIATE BRACING AT MID -HEIGHT OF ALL NEW PARTITION WALLS EXCEEDING 8FT IN HEIGHT. COORDINATES THE LOCATIONS OF WALL MOUNTED FIXTURES/EQUIPMENTS AND PROVIDE SUPPORT BRACING WITH CHANNELS AT POINTS OF ATTACHMENTS. SUPPORT BRACING TO HAVE CAPACITY FOR 200LBS IN AL DIRECTIONS. ❑6 PROVIDE 6" RUBBER BASE AT ALL WALLS - BOTH EXISTING AND NEW EKI PROVIDE SOUND ATTENUATION BATT INSULATION IN ALL NEW STUD WALLS 1ENEW SUSPENDED 2"X2" ACOUSTIC TILE CEILING WITH ALUMINUM GRID IN ENCLOSED OFFICE SPACES AND CORRIDOR BETWEEN OFFICES a PROVIDE NEW 4" CONCRETE SLAB BASE FOR NEW C.U. 10 PROVIDE CARPET TILE IN NEW OFFICES AREA 1 PROVIDE 5/8" G.W.B. PAINTED OVER EXIST, PLYWOOD FINISH 1 2 NEW DUCTWORK FROM UNITS OVER EXIST. WOOD JOIST. PROVIDE INTERMEDIATE CHANNEL FASTENED BETWEEN EXIST. WOOD JOIST AT 16" OIC TO SUPPORT DUCTWORK AS NECESSARY. (REFER TO MECH. PLAN) 13 PROVIDE NEW O/A PENETRATION AND O/A INTAKE GRILL THRU MASONRY WALL TO RECEIVE NEW O/A DUCT FROM AHU. (REFER TO MECH. PLAN) 1 4 CONDENSER LINE TO TERMINATE 4" ABOVE PAVEMENT. 14.1 NEW REFRIGERANT LINES TO THE TOP OVER EXIST. WOOD JOIST THAT GOES OVER THE EXIST. CONC. BEAM TO OUTSIDE AND GOES DOWN THROUGH THE S. S. SHEET MTL TO THE C, U. (REFER TO MECHANICAL PLAN) 15 16GA MTL STUD TV SUPPORT BRACING. PROVIDE BACKING AS REQUIRED. COORDINATE LOCATION WITH EQUIPMENT 1 6 INTERMEDIATE CHANNEL FASTENED BETWEEN EXIST. WOOD JOIST AT 48" O/C TO FASTEN MTL STUD RUNNER FRAME WALL 17 BOTTOM TRACK (20GA) W/ 3/16"0 X 1-1/4" POWER DRIVEN SCREWS @ 16" O/C 18 METAL STUD RUNNER FASTENED TO MTL CHANNEL 1 9 INTERMEDIATE BRACING AT WALLS HIGHER THAN 8'-0" A.F.F. 20 ROOM SIGNAGE (TYP.) REFER TO SIGNAGE SCHEDULE IN SHEET A6.0 21 REPLACE EXIST. THRESHOLD WITH NEW ALUMINUM THRESHOLD 1/2" MAX. HEIGHT. 22 NEW CONDENSER UNITS (REFER TO MECHANICAL PLAN) 23 SOFFIT OVER CORRIDOR WITH 3-5/8" MTL CHANNEL 20GA MIN. FRAMING 16" O/C WITH 5/8" G.W.B. AND PAINT. 9-s NYARKO ARCHITECTURAL GROUP, INC. AA 002935 CHARLES O. NYARKO, A/A AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: CONSULTANT: PROJECT NAME AND LOCATION: ST. LUCIE ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: SECTIONS AND DETAILS PROJECT PHASE: 100x SUBMITTAL ISSUE TE: 9/27/21 DRAWN BY: ®,VV REVIEWED BY: C.N. W RDER NUMBER: ---- $FEET NUMBER Fil Rio us SCALE 1-1/2"-1'-O' SECTION (MONITORING KNEE WALL) i14.1 RESISTANT RIAL HANDLE WENT S (TYP.) DR FRAME 5/8" G.W.B. -5/8" METAL (20ga) JG @ 16" O.C. NT (TYP.) DETAIL NOTE: INSTALLATION SHOP DRAWINGS REQUIRED. THE CONTRACTOR IS TO FIELD VERIFY ALL DIMENSION SCALE :1-1/2'a1'-0" SEMI -RECESSED :D )D CAP aD SHIM EXIST. ROC EXIST. CONCRETE EXIST. MASONRY' EXIST. CONCRETE EXIST, FO TYPICAL EXTERIOR WALL DETAIL SCALE :1/2"-l'-0" SAFETY YELLOW FINISH 6" 0 STD. GALVANIZED STEEL PIPE FILLED W/ CONCRETE FIN. GRADE VOTE: STRENGTH OF _-ONC. TO BE 3000 PSI IN 28 DAYS. POURED CONC (3000 PSI) SCALE :1/,V-T-0" TYPICAL BOLLARD (-DET 7 DETAIL AS.Q A9.0 PRC WORK TYPICAL EXISTING ET •�� 'iM�TLAI TYPICAL FRAME WALL DETAIL malmil I 14 0 to] tymelelB ail EXIST. WOOD JOIST HURRICANE STRAP NOTES 1. PROVIDE ONE CABLE AT EACH 180 DEGREE FOR TOTAL OF 2 PER FAN. 2. NO EQUIPMENT PENETRATION ALLOWED (SCREWS, CLIPS, ETC.) 3. LOCATE TURNBUCKLE SO CABLE CAN BE TENSIONED WITHOUT DAMAGING THE FAN. PROPOSED WORK AREA-1 RUBBER TRANSITION STRIP OVER MTL TRACK EXIST. SEALED SURFACE FLOORING OFFICES AREA NEW CARPET OVER EXIST. CONC. SLAB TYPICAL CARPET — CONC. SLAB RUBBER TRANSITION W/MTL TRACK ANCHORED TO CONC. SLAB DETAIL TYPICAL THRESHOLD DETAIL SCALE: W-T-Ow TYPICAL FRAME WALL EXIST. MASONRY WALL BEYOND C.U. SUPPORT SLA SCALE 1/2' = 1'-0' COMPACT GRAVEL B SECTION NEW CONDENSER UNIT (TYP.) REFER TO MECHANICAL PLAN NEW HURRICANE STRAPS (TYP.) C.U. ANCHORED TO THE CONCRETE SLAB (TYP.) j NEW 4" CONCRETE SLAB W/ 8"X8" THICKENED WITH 1 #5 EXIST. ASPHALT Pg -& A« « EXIST. SOIL TAG DESCRIPTION IMPROVEMENT NOTES FURNITURE SCHEDULE (REFER TO FURNITURE, EQUIPMENT AND ACCESSORY SCHEDULE IN SHEET A4.0 AND A5.0) #5 CONT. NEW CONCRETE FOOTING (TYP.) IMPROVEMENT NOTES TAGS DESCRIPTION REMARKS aIN THE INTERIOR SIDE OF EXTERIOR WALL, PROVIDE METAL FURRING STRIPS @ 16" O/C, R-7.3 THERMAL INSULATION AND 5/8" G.W.B. AND PAINT L2] EXIST. CONCRETE SLAB: CLEAN AND SEAL SURFACE. UNDER EXIST. WOOD TRUSSES: PROVIDE NEW ATTIC SPACE THERMAL INSULATION (FIBERGLASS) WITH PAPER BACK. PROVIDE NEW 5/8" G.W.B. CEILING IN PROPOSED WORK AREAS AND MECH./STORAGE ROOM. PREPARE G.W.B. CEILING TO RECEIVE NEW SURFACE MOUNTED LIGHT FIXTURES. (REFER TO ELECTRICAL PLANS.) EXISTING ATTIC SPACE VENTILATION aNEW INTERIOR PARTITION WALL WITH 3-5/8" MTL STUDS (20GA) @ 16" O/C AND WITH 5/8" G.W.B. PROVIDE INTERMEDIATE BRACING AT MID -HEIGHT OF ALL NEW PARTITION WALLS EXCEEDING 8FT IN HEIGHT. COORDINATES THE LOCATIONS OF WALL MOUNTED FIXTURES/EQUIPMENTS AND PROVIDE SUPPORT BRACING WITH CHANNELS AT POINTS OF ATTACHMENTS. SUPPORT BRACING TO HAVE CAPACITY FOR 200LBS IN AL DIRECTIONS. HlPROVIDE 4" RUBBER BASE AT ALL WALLS - BOTH EXISTING AND NEW EflPROVIDE SOUND ATTENUATION BATT INSULATION IN ALL NEW STUD WALLS NEW SUSPENDED 2"X2" ACOUSTIC TILE CEILING WITH ALUMINUM GRID IN ENCLOSED OFFICE SPACES AND CORRIDOR BETWEEN OFFICES PROVIDE NEW 4" CONCRETE SLAB BASE FOR NEW C.U. 1 PROVIDE CARPET TILE IN NEW OFFICES AREA 1 1 PROVIDE 5/8" G.W.B. PAINTED OVER EXIST. PLYWOOD FINISH 12 NEW DUCTWORK FROM UNITS OVER EXIST. WOOD JOIST. PROVIDE INTERMEDIATE CHANNEL FASTENED BETWEEN EXIST. WOOD JOIST AT 16" O/C TO SUPPORT DUCTWORK AS NECESSARY. (REFER TO MECH, PLAN) 13 PROVIDE NEW O/A PENETRATION AND O/A INTAKE GRILL THRU MASONRY WALL TO RECEIVE NEW O/A DUCT FROM AHU. (REFER TO MECH. PLAN) 14 CONDENSER LINE TO TERMINATE 4" ABOVE PAVEMENT. 14.1 NEW REFRIGERANT LINES TO THE TOP OVER EXIST. WOOD JOIST THAT GOES OVER THE EXIST. CONC, BEAM TO OUTSIDE AND GOES DOWN THROUGH THE S. S. SHEET MTL TO THE C. U. (REFER TO MECHANICAL PLAN) 1 rJ 16GA MTL STUD TV SUPPORT BRACING. PROVIDE BACKING AS REQUIRED. COORDINATE LOCATION WITH EQUIPMENT 1 6 INTERMEDIATE CHANNEL FASTENED BETWEEN EXIST. WOOD JOIST AT 48" O/C TO FASTEN MTL STUD RUNNER FRAME WALL 1 7 BOTTOM TRACK (20GA) W/ 3/16"0 X 1-1/4" POWER DRIVEN SCREWS @ 16" O/C 18 METAL STUD RUNNER FASTENED TO MTL CHANNEL 1 g INTERMEDIATE BRACING AT WALLS HIGHER THAN V-0" A.F.F. 2� ROOM SIGNAGE (TYP.) REFER TO SIGNAGE SCHEDULE IN SHEET A6.0 21 REPLACE EXIST. THRESHOLD WITH NEW ALUMINUM THRESHOLD 1/2" MAX. HEIGHT. 22 NEW CONDENSER UNITS (REFER TO MECHANICAL PLAN) 23 SOFFIT OVER CORRIDOR WITH 3-5/8" MTL CHANNEL 20GA MIN. FRAMING 16" O/C WITH 5/8" G.W.B. AND PAINT. NYARKO ARCHITECTURAL GROUP, INC. AA 002935 CHARLES O. NYARKO, A/A AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: CONSULTANT: PROJECT NAME AND LOCATION: ST. LUCIE ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: DETAILS PROJECT PHASE: 100/ SUBMITTAL ISSUE DATE: 9/27/21 DRAWN BY: O.V. I REVIEWED BY: C.N. 41 WORK.E%ER NUMBER: ---- SHE UMBER A9,0 FIRE EXTINGUISHER DETAIL DETAIL SCALE :1/2"-1'-0" on-WARA M-) I LVA 1 V3 hiffleClu UNTAFTI141 0 14 XC EF. NES DN METAL HASE 0 8"0 INSULATED METAL O/A AIR TO CONNECT TO MIXING 0 PLENUM BELOW EXIST. CATCH CU-1 BASIN — 0 10"0 INSULATED METAL ON/OFF MOT. O/A */A AIR TO CONNECT TO DAMPER MIXING PLENUM CONDENSER LINE TO TERMINATE 4" ABOVE AHU-1 PAVEMENT 6TONS 1-1/2" CD LINE BELOW 1 OX6 A/I TIED TO WALL @ 8" LOUVER SLOPE 12X6 A/I LOUVER R/A DUCT DOWN TO CONNECT TO TUP BULL I MIXING PLENUM j 044p, awzm 10110 ­Iftft.4 12" (1 2424 CD 300 CFM 1 0 0.0 120 1,' L611A 26X12 I Q m 24X12 ill CD --TRAP 24X16 D 6x6 SR 100 CFM SHEETMET INSULATED MIXING PLE UM ATTACHED '----,TO INLET 0 AHU 30X16 2424 CD 300 Cf.M IM 2424 CD 300 CFM E-11 1 0 110 9 im 2424 CD 250 CFM 2424 CD 250 CFM WORK AREA 1 2424 CD 1 ()Xi 0- 250 CFM 110 10 2 24)114�D 2424 424 E��) CFM 2424 CD RAG 250 CFM • 1 Ho 0 6x6 CD 1 110 50 CFM 0 _71 2424 CD 8flo -------- 8x8 iTxfF 14x1 200 CFM 110 -30 6 10110 2424 CD 424 RA 10.0 ""o 2 200 CFM tG C 24,44 250 F1 R A GI 1 0­X-1 0 X10 1 y.XI10 INISPLIT 242 2424 6 INDOOR j _4 RA RAG 10, _CFM UNIT --3/4" CD TRAP REF LINES OVERHEAD REF. LINES DN IN METAL CHASE MINISPLIT o OUTDOOR UNIT 0 ri I 'a RRIV61 100, Vill[ NYARK0 ARCHITECTURAL GROUP, INC. AA 002935 CHARLES 0. NVARK0, AIA AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: E No. 5 0% STATE OF ®®®®S®`4�O 0 lw- RID MAIL. MWO �' CONSULTANT: PROJECT NAME AND LOCATION: STI Lmwmffo t 4 ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: z R � WITAR PROJECT PHASE: 100% SUBMITTAL ISSUE DATE: 9/27/21 DRAWN BY: ^ARCOS 1 REVIEWED BY: C.N. MISRAHI WORK ORDER NUMBER: SHEET NUMBER w NMI Z M-1 HVAC GENERAL NOTES (REFER TO DN 15 SPECIFICATIONS ATTACHED TO THESE SET OF DWGS FOR MORE INFORMATION 1. HVAC DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND REPRESENT EXISTING CONDITIONS BASED ON DRAWINGS AND SITE OBSERVATIONS. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL ACTUAL CONDITIONS INCLUDING, DUCTWORK AND PIPING LOCATIONS AND SIZES. 2. DUE TO DRAWINGS BEING DIAGRAMMATICAL IN NATURE ALL RISERS & DROPS ARE NOT SHOWN - CONTRACTOR SHALL INCLUDE THESE IN THE BID. WHERE POSSIBLE ALL RISERS & DROPS SHALL BE CONSTRUCTED USING 45 DEGREE OR LONG RADIUS ELBOWS. 3. PROVIDE AND INSTALL NECESSARY DUCTWORK TRANSITIONS AND PIPING INCREASERS/REDUCERS AS REQUIRED FOR EQUIPMENT CONNECTIONS. CONSULT MAANUFACTURER'S DATA FOR ACTUAL DUCTWORK AND PIPING CONNECTIONS SIZES, INCLUDING, BUT NOT LIMITED TO THOSE SHOWN. 4. PROVIDE MANUAL VOLUME DAMPERS AT ALL LOW PRESSURE BRANCH DUCTS TO INDIVIDUAL DIFFUSERS AND GRILLES AND TO ALL LOW PRESSURE BRANCH DUCTS TO REHEAT COILS. PROVIDE DAMPERS AS CLOSE AS POSSIBLE TO BRANCH CONNECTION TO MAIN. SEE DIFFUSER AND GRILLE SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL INFORMATION, 5. SCHEDULE NEW CONSTRUCTION WORK WITH THE OWNER WELL IN ADVANCE. CONSTRUCTION WORK AND DEMOLITION SHALL BE PERFORMED AT SUCH TIMES AND UNDER SUCH CONDITIONS AS SUITS THE OWNER. 6. ALL FINISHES AND SURFACES TO REMAIN WHICH ARE DAMAGED DURING CONSTRUCTION WORK SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST TO THE OWNER. 7. SEAL ALL WALL, ROOF, AND FLOOR PENETRATIONS AIR TIGHT AT PIPE, DUCTWORK, AND CONDUIT PENETRATIONS. ALL PENETRATIONS THRU FIRE RATED WALLS TO BE SEALED AS PER UL DETAILS. 8. DO NOT BLOCK TUBE PULL OR SERVICE SPACE ON EQUIPMENT WITH PIPING, DUCTWORK, ETC. (FLANGED OR REMOVABLE SECTIONS MAY BE USED IN SOME INSTANCES WHERE TIGHT CLEARANCES EXISTS). 9. NO PIPING, DUCTWORK, OR CONDUIT SHALL BE INSTALLED UNTIL IT IS COORDINATED WITH ALL OTHER TRADES AFFECTED. PROVIDE ALL OFFSETS REQUIRED TO AVOID INTERFERENCES WITH OTHER TRADES; EXISTING CONDITIONS AND WITH THE STRUCTURE, INCLUDING, BUT NOT LIMITED TO, THOSE SHOWN. 10. DUCTWORK DIMENSIONS ARE INSIDE CLEAR. 11. FIELD VERIFY TO ELECTRICAL, PLUMBING, FIRE PROTECTION, ARCHITECTURAL AND STRUCTURAL FOR COORDINATION WITH THESE DRAWINGS. 12. DUCTWORK ROUTED PARALLEL TO A WALL, RATED OR CORRIDOR SHALL BE INSTALLED WITH MINIMUM 6" CLEARANCE TO ALLOW FOR INSPECTION OF WALL PENETRATIONS. CONTRACTOR SHALL PROVIDE 12" CLEARANCE WHERE POSSIBLE, COORDINATE. 13. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PERFORM ALL WORK NECESSARY TO PREPARE THE STRUCTURE FOR THE INSTALLATION AND/OR ANDOANLYO DAMAGED OF THE I SURFACETS SHALL BEHREPA'IREDENINNGS AND FINISHED TO MATCH EXISTING. 14. IN ORDER TO MAINTAIN THE EXISTING ROOF WARRANTY, ALL ROOFING WORK (CUTTING AND REPAIRS) SHALL BE PERFORMED BY THE OWNER'S ROOF WARRANTY VENDOR (PAID FOR BY THIS CONTRACTOR). 15. ALL DUCTWORK SHALL BE SUPPORTED IN STRICT COMPLIANCE WITH SMACNA OR FLORIDA MODEL EFFICIENCY CODE, WHICHEVER IS MORE STRINGENT. 16. EXISTING SYSTEMS SHOWN ON THE DRAWINGS ARE BASED ON AVAILABLE RECORD DRAWINGS. THIS INFORMATION IS ONLY PARTIALLY VERIFIED. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY AND INVESTIGATE ALL CONDITIONS THAT AFFECTS THE WORK PRIOR TO SUBMITTING THE BID, 17. INSTALL CONTROL PANELS TO PROVIDE FOR 3'-0" MIN. CLEARANCE IN FRONT OF PANEL. 18. ALL DIFFUSERS IN SAME SPACE SHALL HAVE THE SAME FULL FACE SIZE USING LARGEST SIZE REQUIRED FROM DIFFUSER AND GRILLE SCHEDULE. 19. REFER TO ELECTRICAL, PLUMBING, FIRE- PROTECTION, STRUCTURAL, AND ARCHITECTURAL DRAWINGS FOR COORDINATION WITH THIS DRAWING. PROVIDE CLEAR ACCESS TO FIRE DAMPERS, SMOKE DAMPERS, VALVES AND PROVIDE NOA (NOTICE OF ACCEPTANCE) NUMBER OR ENGINEERED DETAIL OF HOLD DOWN DEVICE TO MEET FBC WINDLOAD FOR ALL EXTERNAL MOUNTED EQUIPMENT. PROVIDE MANUFACTURERS CERTIFIED DATA ON ALL EXTERIOR MOUNTED EQUIPMENT DURING SUBMITTAL PHASE, WHICH INDICATES THAT THE EQUIPMENT CAN WITHSTAND A MINIMUM OF A 150 MPH WIND LOAD. ALL NEW RETURN DUCTWORK, EXHAUST DUCTWORK, AND SUPPLY DUCTWORK WAS SIZED ON THE FOLLOWING CRITERIA: EXHAUST DUCT MAINS: APPROXIMATELY 0,08" W.C./100 FT, SUPPLY AIR DUCTS DISCH, SIDE OF TERMINAL UNITS: APPROXIMATELY 0,04 THRU 0.08" W.G./100 FT. RETURN AIR DUCT MAINS: APPROXIMATELY 0.05" W.G./100 FT. RETURN AND EXHAUST BRANCH MAINS: 0.03 THRU 0.05" W G./100 FT. SUPPLY AIR DUCTWORK INLET SIDE OF TERMINAL UNITS: APPROXIMATELY 0.2" W.G./100 FT. PROVIDE CLEAR ACCESS TO VALVES AND DAMPERS. CEILING ACCESS DOORS ARE REQUIRED FOR ACCESS TO SERVICE EQUIPMENT SUCH AS VALVES, AUTOMATIC DAMPERS, FIRE AND DAMPERS, AND CAV BOXES. COORDINATE CEILING ACCESS DOOR LOCATIONS AND TYPE WITH ARCHITECT. ALL DUCTS AND APPARATUS CASINGS ARE TO BE THOROUGHLY CLEANED BEFORE COILS ARE OPERATED, 26. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE SECTIONS OF THE NFPA STANDARDS, ANSI STANDARDS, THE LOCAL BUILDING CODE (FBC-2009), SMACNA, ASHRAE, NFPA 90A ,NOISE & HEIGHT ORDINANCES, PLANS AND SPECIFICATIONS. 27. ALL MATERIALS SHALL BE NEW AND ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, PRODUCT APPROVAL, RULES AND ORDINANCES, ANY DAMAGED EQUIPMENT SHALL BE REPLACED OR 28. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS PANELS, CONTROL SYSTEMS, DEVICES, PERMITS AND SERVICES NECESSARY FOR FURNISHING AND INSTALLING A COMPLETE OPERABLE MECHANICAL SYSTEM. 29. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR AND TEXTURE WITH ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH BENJAMIN MOORE EPDXY ENAMEL 182. 30. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING, AND WALL OPENINGS SHALL BE BY THE GENERAL CONTRACTOR. 31. ALL OPENINGS( IN BUILDING )STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE WITH H LARGER RE RETARDANT SILICONE FOAMH(E OUCHADSE -FOAM CTC PR PROTECT855 BYACHDASE L TECHNOLOGY CORP,) UNLESS OTHERWISE INDICATED ON HVAC DWGS. 32. BUILDING HVAC CALCULATIONS ARE BASED ON THE FOLLOWING: A. INDOOR DESIGN: SUMMER 75 DDB/50% RH, WINTER 72 DDB. B. OUTDOOR DESIGN: SUMMER 91 DDB/78 DWB, WINTER 42 DDB. C. BUILDING CONDITIONS: GLASS U VALUE 1.04 GLASS S.C. 0.80 WALL U VALUE 0.156 ROOF U VALUE 0.052 33. AIR QUALITY SHOULD BE TESTED BEFORE OCCUPA NCY AND SHOULD BE INSTRUMENTED AND MONITORED THEREAFTER, OR AT LEAST AT REGULAR INTERVALS 1. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPE. 2. PROVIDE OFF WHITE FINISH (SUBJECT TO ARCHITECT'S APPROVAL). 3. ALL DUCTWORK WHERE ALLOWED BY LOCAL CODES AND AND CEILING RATING SHALL BE 2" MEDIUM PRESSURE DUCT, SEAL CLASS "C" AND AS FOLLOWS: A. S/A & R/A - GALVANIZED SHEETMETAL AND DUT LINER FHC 25/50 R=7.4 B. LAB/HOOD EXHAUST AIR - TYPE 316 STAINLESS STEEL C. OUTDOOR AIR - R6 INSULATED GALVANIZED SHEETMETAL 4. ALL DUCTWORK AND DIFFUSERS SHALL BE RATED FOR THE USE, PRESSURE AND TEMPERATURE SPECIFIED AND AS REQUIRED BY THE CEILING SYSTEM RATING. 5. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH SMACNA" STANDARDS AND LOCAL BUILDING CODES AND MDCPS. 6. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 7. SEAL ALL DUCTS, JOINTS AND SEAMS IN AN APPROVED MANNER AND INSURE AGAINST LEAKAGE. 8. PROVIDE ACCESS DOORS AS REQUIRED FOR ALL MECHANICAL EQUIPMENT TO SERVICE AND VISUALLY CHECK ROTATION OF FANS AND MOTORS, POSITION OF DAMPERS, REPLACE FIRE DAMPER LINKS, ADJUST OR REPLACE CONTROLS, ETC, 9. PROVIDE VANED ELBOWS IN ALL CASES, SPUTTER DAMPERS WHERE INDICATED ON DRAWINGS AND VOLUME CONTROL DAMPERS IN ALL BRANCH DUCTS OR DIFFUSER CONNECTIONS. 10. TERMINAL AIR DISTRIBUTION DEVICES SHALL BE AS FOLLOWS: CEILING DIFFUSER: EQUIV. TO TITUS MODEL TDC-AA, RETURN REGISTER: EQUIV. TO TITUS MODEL 355 FL, (ALL ROOMS) EXHAUST REGISTER: EQUIV. TO TITUS MODEL 50F EGG CRATE, (LAB AREA) COORDINATION NOTES: 1. AlC CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS WORK FOR SIZE, LOOCATION, CLEARANCE, ACCESS AND ELECTRICAL CHARACTERISTICS WITH ALL OTHER TRADES AND TO PROVIDE SHOP DRAWINGS TO THE ENGINEER FOR REVIEW BEFORE INSTALLATION OF DUCTWORK OR EQUIPMENT. SHOP DRAWING WILL INCLUDE BEAM OR STRUCTURE ELEVATION & REQUIRED EQUIPMENT ACCESS AREAS. 2. WALL, ROOF, AND CEILING OPENINGS INDICATED ON CONTRACTOR DRAWINGS ARE NOMINAL DIMENSIONS ONLY AND ALL DUCT,PIPE OR EQUIPMENT PENETRATIONS SHALL BE SLEEVED AND FIRE RATED AS REQUIRED, ADJUST OPENINGS 3. COORDINATE LOCATION OF CEILING DIFFUSERS, GRILLES AND REGISTERS IN THE FIELD WITH LIGHTS, SPRINKLERS AND ARCHITECTURAL ELEMENTS. 4. COORDINATE LOCATION OF A/C UNITS, THERMOSTATS, FANS AND DUCTWORK WITH BUILDING STRUCTURE AND OTHER TRADES SO THAT NO INTERFERENCES OCCUR. 5. IN GENERAL, DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C CONTRACTOR TO COORDINATE THESE AS REQUIRED. 6. MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER, 7. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING, ORDERING, FABRICATION OR INSTALLATION OF MATERIALS OR EQUIPMENT, MECHANICAL ROOM NOTES 1. REFER TO ARCHITECTURAL, STRUCTURAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS FOR COORDINATING ALL INSTALLED MATERIALS. 2. EQUIPMENT SIZES AND SERVICES SPACE REQUIREMENTS MAY VARY BETWEEN DIFFERENT MANUFACTURERS. CONSULT MANUFACTURER INSTALLATION DRAWINGS SUBMITTED AND APPROVED FOR APPLICATION WITH MECHANICAL ROOM EQUIPMENT. I SLEEVE PIPE PENETRATION AT WALLS AND FLOORS. 4. DO NOT BLOCK TUBE PULL OR SERVICE SPACE ON EQUIPMENT WITH PIPING DUCTWORK, ETC. FLANGED OR REMOVABLE SECTIONS MAYBE USED IN SOME INSTANCES WHERE TIGHT CLEARANCES EXIST, 5. REFER TO DRAWINGS AND EQUIPMENT SCHEDULES FOR BRANCH PIPE SIZES TO INDIVIDUAL EQUIPMENT. 6. ALL CAPPED LINES FROM EQUIPMENT SHALL BE IDENTIFIED WITH STENCILED SERVICE. TYPE WITHIN 3'-0" OF CAP, 7. PIPE DRAIN LINES FROM EQUIPMENT TO NEAREST FLOOR DRAIN. REFER TO DRAWINGS FOR LOCATIONS OF FLOOR DRAINS. 8. PROVIDE BELT GUARDS FOR ANY EXTERNALLY BELT DRIVEN EQUIPMENT. h ECIIANICAL EQUIPMENT NOTES 1. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L. LISTED WHERE APPLICABLE AND RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND SHALL BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS, ETC. TO FUNCTION PROPERLY. 2. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS AND AHU'S OF 2000 CFM OR ABOVE. ALL SMOKE DETECTORS SHALL BE BY ONE MANUFACTURER; COORDINATE VOLTAGE ETC: WITH ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING, UPON DETECTION, SMOKE DETECTORS SHALL SHUT DOWN ASSOCIATED AIR MOVING EQUIPMENT. 4. PROVIDE BACKDRAFT DAMPERS ON ALL EXHAUST FANS AND/OR INLINE FANS. 5. PROVIDE VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS CALLED FOR IN THE SPECIFICATIONS, IF NOT SPECIFIED, AS RECOMMENDED BY MANUFACTURER FOR QUIET OPERATION (WITH 99% ISOLATION EFFICIENCY), 6. PROVIDE A MIN. OF 10' CLEARANCE BETWEEN O/A INTAKES AND VTR OR EXHAUST OPENINGS. 7. INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT AIR DEVICES, EXTRACTORS, DAMPERS, AHU'S & FAN RATES, ETC. TO PROVIDE THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES, PROVIDE T & B REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS, SIGNED AND SEALED BY A REGISTERED FLORIDA ENGINEER. PROVIDE FINAL BALANCING FOR ALL SYSTEMS TO SATISFACTION OF OWNER AND ENGINEER.T & B CONTRACTOR SHALL VISIT JOB SITE DURING CONSTRUCTION TO ENSURE THAT ALL DUCTS, DAMPERS, ETC, ARE INSTALLED FOR PROPER AND QUIET AIR DELIVERY. 8. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE INSTALLATION. 9. RUN INSULATED CONDENSATE DRAINS AS PER PLUMBING DRAWINGS. 10. MOUNT ALL ROOFTOP EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS AS REQUIRED BY LOCAL CODES, ALL CURBS SHALL EXTEND 8" MIN. ABOVE FINISHED ROOF. 11. ALL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, SLABS, ETC, AS REQUIRED AND COORDINATED WITH THE STRUCTURAL ENGINEER. REWORK BAR JOIST CROSS BRACING AND PROVIDE NECESSARY TRANSITIONS AS REQUIRED FOR DUCTWORK INSTALLATION. 12. ALL INSULATION WILL HAVE FIRE/SMOKE RATING LESS THAN 25/50. 13. PROVIDE MOTOR STARTERS AS FOLLOWS (UNLESS OTHERWISE RECOMMENDED BY MOTOR MANUFACTURER): A: PROVIDE OVERLOAD PROTECTION - 1/3 HP AND ABOVE (ALL PHASES). B: PROVIDE ACROSS THE LINE VOLTAGE STARTING BELOW 25 HP. 14. ALL OUTDOOR EQUIPMENT SHALL COMPLY WITH LOCAL ZONING NOISE ORDINANCES, MIN. REQUIREMENT SHALL NOT EXCEED A NOISE LEVEL OF 65 DB AS MEASURED RADIALLY 30 FT FROM THE EQUIPMENT IN ALL DIRECTIONS. 15. FILTERS SHALL BE IN PLACE DURING CONSTRUCTION. PROVIDE A NEW SET PRIOR TO TEST AND BALANCE AND A FINAL SET AT THE END OF ONE YEAR SERVICE PERIOD. 16. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS, OR MECHANICAL EQUIPMENT. 17. PROVIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT OR SYSTEMS. PROVIDE 5 SETS OF SUBMITTALS ON ALL HVAC EQUIPMENT. SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED INFORMATION. 18. HVAC CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, DUCTWORK, THERMOSTATS, AND ALL OTHER EQUIPMENT,PARTS AND LABOR UNDER THESE DRAWINGS AND SPECIFICATIONS FOR A PERIOD OF ONE (1) YEAR AFTER C.O. OF BUILDING. ANY REPAIRS REQUIRING SYSTEM SHUT DOWN WILL BE DONE DURING NON OPERATIONAL PERIODS. HVAC CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO BIDDING AND PURCHASING ANY EQUIPMENT. MINI SPLIT AC UNIT SCHEDULE (MITSUBISHI) NOM. CONDENSE FAN COIL TOTA COOLING/HEATING CF(f l hl) CONDENSER DESIGNATIO ON SEE REFRI MODEL NUMBERODEL NUMBER FCU-1 FCU-2 FCU-1 FCU-2 (T0� %H50OLING HEATIN EIG (LBS TBR. CI MIN- M EFRIGERANT XXSUCT SLQD' iN . CTRI RVICE AREA SERVE LH L FCU/CU-3 0.9 16 R410 MUY-GEO IVP SY-GE09NA 175/250 9 9 9 10.9 9 9 66 14-15 PER MANUF. RECOMMENDAT 208-1-6 ONS IT ROOM NU I L5: 1. MITSUBISHI IS THE BASIS OF DESIGN AND THE STANDARD FOR COMPARISON. 2. MECHANICAL CONTRACTOR SHALL SIZE LINES PER MANUFACTURER'S RECOMMENDATION BASED ON ACTUAL ROUTING OF REFRIGERANT LINES. 3. MANUFACTURER SHALL PROVIDE COMPLETE FACTORY INSTALLED HI/LOW PRESSURE SWITCH, HI CAPACITY DRYER, ANTI-SH CYCLING DEVICE, CRANK CASE HEATER, SOLENOID VALVE AND NON -BLEED EXPANSION VALVE. 4. PROVIDE AN AUTOMATIC FLOW SWITCH WITH ALARM /LIGHTIN DICATOR IN EACH OF THE AUXILIARY DRAIN PANS. 5. MANUFACTURER SHALL PROVIDE TEN YEAR COMPRESSOR WARRANTY. ABBREVIATIONS: T SR SIDEWALL REGISTER CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE AHU AIRHANDLING UNIT CU CONDENSING UNIT EF EXHAUST FAN RAG RETURN AIR GRILLE AC LEGEND: 17/1 SUPPLY AIR GRILLE RETURN AIR GRILLE FITI HARDDUCT & TRANSITION FLEX DUCT O THERMOSTAT. INSTALL 4' A.F.F. SD DUCT SMOKE DETECTOR SPLIT AC UNIT SCHEDULE (TRANE) DESIGNATI NOM. �ON SEE EER REFRI CONDENSE AIR HANDLER TOTA CFM COOLING CAPACITY (MBTU�i6/62 °F CONDENSER WEIGH-B TlE( INCHES 0 D. (LBS) MIN -MAX SUCT.-LIQ. AIR HANDLER MOTO S.P. WEIGH BHP in. W. .)(LBS) � KW ELEeTRI SERVICE MODEL NUMBER TC SC AHU/CU- 6 12.9 R410A TWE0724B TTA0724D 2400 69.7 56.1 275 23-30 MAN UF. 2 1 323 12 208-3- AHU/CU- 5.0 16.0 R41 0A 4TTR7060A TEM6AOC60 2000 58.8 45.5 275 41-60 FiECOMMENDATIO �4 0.5 168 10 208-1-6 RECOMMENDATIONS AHU Notes: 1) Provide single piece vertical/horizontal indoor fan coil. 2) Provide factory installed belt driven blower motor. 3) Provide factory installed noncorrosive composite drain pan. 4) Provide factory installed single point power connection. 5) Provide factory installed thermal expansion valve. 6) Provide field installed electric heat. 7) Provide field installed OEM programmable thermostat. CU Notes: 1) Provide 2 stage single circuit condensing unit. 2) Provide factory installed crank case heater. 3) Provide factory installed phase monitor. 4) Provide factory installed copper tube aluminum fin condenser coil. O/A CALCULATIONS AS PER FMC 403 AHU-1 5 CFM/P X 20P + 2572 SO FT X 0.06 CFM/SQ FT = 204.32 CFM REQ. 300 CFM 0/A PROVIDED THRU AHU-1 AHU-2 5 CFM/P X 20P + 1720 SO FT X 0.06 CFM/SQ FT = 203.2 CFM REQ. 250 CFM O/A PROVIDED THRU AHU-2 BOTH UNITS ARE TO BE PROVIDED WITH O/A MOTORIZED DAMPER TO BE OPEN 100% WHEN UNIT IS ON AND CLOSED 100% WHEN UNIT IS OFF I A "I 0 L NYAR.KO ARCHITECTURAL GROUP, INC. AA 002935 CHARLES O. IVYARKO, A/A AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL: �-%o�ogI 0 °° E° No. 5 ®_ m m ®° STATE OF kj 0 7f411 m %440� CONSULTANT: PROJECT NAME AND LOCATION: ST. LUCIE COUNTY TRAFFIC OPERATIONS OFFICES RENOVATION ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: HVAC NOTES AND DETAILS I PROJECT PHASE: 100% SUBMITTAL I ISSUE DATE: 9127/21 tDRAWN BY: MARCOS I REVIEWED BY: C.N.1I WORK ORDER NUMBER: I SHEET NUMBER M-2 IMPORTANT! POST TENSI❑N SLAB. )KIMP❑RTANT! PREVENT EXERCISE EXTREME CAUTION IN BENDING OF STRAP AT PLACING INSERTS TO AV❑ID STEEL 90° BEND UNDER LOAD TENSION CABLES. O o O a O o O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 O 0 0 O O O O O 0 0 0 0 o O O O O O o O O 0 O O O O 0 O O O O O 0 0 O O O O O O O O O O O O O O O O O O O O O O O O O O O 0 = O O 0 O - 0 0 O 0 O O O O O 0 = O 0 O O = 0 O 0 O O O O WASHER EXPANSION SHIELDS wxCONCRETE ANCHORS EXPANSION NAIL 0 0 0 0 O O 0 0 0 0 0 0 00 O 0 0 O O O O O O O 0 0 O O O O O O O O O O O a 0 0 0 0 0 0 O O 0 O o 0 O O 0 0 O O O O O O O 0 0 0 O O O O O O O O x IMPORTANT! PREVENT STRAP BENDING OF STRAP AT 9CF BEND UNDER LOAD, ASHER 3aw 3b)K NUT wx ALSO FOR USE IN HANGING VAV BOXES AND AIR VALVES (AV) HANGER S ASD OF HANGERASTRAME P P S 10 ATI❑N HANGERS FOR STACKED DUCTS REINFORCEMENTS MAY BE USED FOR ATTACHMENT IF IT QUALIFIES FOR BOTH DUTIES D❑ NOT EXCEED LOAD RATING FOR METHOD USED HANGER STRAPS THREADED ROD 30" DUCTS & SMALLER SUPPLY, RETURN, _ & EXHAUST TYPICAL --- I r IF BOLTED 31' DUCTS & LARGER SCREWS MAX, 10' -0" C. LOW PRESSURE DUCTWORK HANGER DETAIL 4" MIN CLEARANCE AROUND AHU WALL STRUCTURE THERMOSTAT z_ Cu -u < a- GFM CLOSURE #10X1-1/4 SHEETMETAL SCREWS 12" (MAX) O.C. MIN 2 PER SIDE GFM CLOSL FLANGE 1—Y2" SQ. WASHEF 12" (MAX) O.C. 2 PER SIDE #10X1-1 /4"- SHEETMETAL SCREWS 22 GAUG SHEETME 1X3 22 GAUGE SHEETMETAL 1X1X1 CHANEL FASTENED TO METAL FLANGE SPOT WELD TO GFM CLOSURE EQUIPMENT FLANGE (OVER POCKET LOCK AND FLANGE DUCT DUCT BOARD) BEARING PLATE GFM FLANGE ON SHEETMETAL CLOSURE DUCT, CLINCH LOCK OR DOVE —TAIL #10X1-1/4" SHEETMETAL METAL DUCT PER SCREWS AND 1—Y2" SQ. SPECIFICATION WASHERS 12" (MAX) O.C. TO ATACH DUCT BOARD TO 22 GA "J" SHEETMETAL SLEEVES GFM rl AAIf' r #1OX1-1/ SCREWS MIN 2 PE 22 GAUGE SHEETMETAL 1 X1 X1 CHANEL FASTENED TO METAL FLANGE REFER TO SMACNA STANDARDS FOR OTHER TYPES YPICAL DUCT AND EQUIPMENT ONNECTION DETAILS AIR HANDLING UNIT EXTEND TO AND TERMINATE OVER NEAREST DRAIN: SLOP LINE 1/8 INCH VERTICAL TO ONE FOOT HORIZONTAL AHU DRAIN CONNECTION SHORT NIPPLE -� 1 rr� m MIN. DROP 2 INCHES �N\ FULL SIZE OF AHU DRAIN x CONNECTION MINIMUM SIZE 1 1 /4" INCH. as � mFOR BLOW—THRU UNITS: NOT LESS THAN TOTAL FAN SP + 1" FOR DRAW—THRU UNITS: ( UP TO 3 TONS — MIN 2") NOT LESS THAN OVER 3 TONS — MIN 3" TOTAL FAN SP + 1" NOTE: 2X+Y SHALL EQUAL TOTAL FAN SP+2" (MINIMUM) TYPICAL AIR HANDLING UNIT CASING DRAIN 1-m SUPPLY AIR DUCT FLEX -CONNECTION AIR HANDLING UNIT ---- REFRIGERANT LINES CONDENSATE DRAIN _�T j/-- WITH TRAP (3" SEAL) NEOPRENE PAD AIR HANDLING UNIT SUPPORT (1 "X1 "X1 /4" STEEL ANGLE FRAME) EXTERIOR SHEETMETAL PAINTED FLAT BLACK (OR OTHER COLOR AS DIRECTED BY ARCHITECT) BY HVAC CONTRACTOR BUG SCREEN PITCH TO DRAIN CAULKING LOUVER BY 15` GENERAL CONTRACTOR MIN 1 1/2"X1 1/2"X1/8" ANGLE 2" MINIMUM FOR DUCT CONNECTION SHEETMETAL FASTENED TO ANGLE 6" ON CENTER ANGLE FASTENED TO LOUVER AT INTERMEDIATE SUPPORTS AND FRAMES CAULKING NOTES: FASTENED 6" ON CENTER 10 SUPPORT PLENUM FROM FLOOR OR STRUCTURE ABOVE W/GALVANIZED STEEL ANGLES AND CHANNELS. AIRFLOW DIRECTIO PLENUM LOUVER CONNECTION INSULATI NOTE: CUT INLET AND EXHAUST TUBES T LENGTH SPECIFIE BY MANUFACTURER w® DUCT INLET TUBE HOLES FACE UPSTREAM OF AIR FLOW .—EXHAUST TUBE 24 GA, META INSULATION NOTE 2 12x12 MINIMUM SIZ DUCT ACCESS DO❑ SMOKE DETECTOR H❑USING MOUNTED TO SIDE OF DUCT IN ❑ T E S: 1, DETAIL SHOWS GENERAL INSTALLATI❑N METHODS, REFER TO INDIVIDUAL MANUFACTURER FOR THEIR SPECIFIC INSTALLATION AND LOCATION INSTRUCTIONS. 2, STANDOFF BRACKET NOT REQUIRED ON NON -INSULATED DUCT, DUCT MOUNTED SMOKE DETECTOR UPPER ATTACHMENT PER SMACNA MAX. SAG 1/2" PER FOOT BETWEEN SUPPORT POINTS - DUCT SEALER AT 45" TAKEOFF FLEXIBLE DUCT 45' TAKEOFF OR ROUND OR ROUND BELLMOUTH COLLAR 8'-0' MAXIMUM BELLMOUTH COLLAR CONNECTION TO MAIN LENGTH MOUNT IN SIDE OF DUCT SLIPPY AIR ADJUSTABLE CLAMP DUCT 0 MAXIMUM D/8 OFFSET ALLOWED INN LAST D INCHES TO DEVICE WHERE D IS THE INTERNAL FLEX DIAMETER _ SADDLE —�` SEE NOTE 3 LOCKING VOLUME DAMPER NECK SIZE TO MATCH FLEX ADJUSTABLE CLAMP DUCT SIZE INDICATED DUCT SEALER ALTERNATE TAP LOCATION FOR DIFFUSER BELOW DUCT INSULATE TOP PANEL OF LAPIN DIFFUSER 10 NOTES CEILING (T-BAR SHOWN. 1. FLEXIBLE DUCTS SHALL BE ONE PIECE AND SHALL NOT BE SPLICED TOGETHER . GYP. BOAARD SIMILAR) 2. EXTEND FLEXIBLE DUCT INSULATION TO DUCT/DIFFUSER PANEL INSULATION AND SEAL WITH MASTIC . AIR DISTRIBUTION DEVICE LAYIN SHOWN . 3. MINIMUM 1 1/2" WIDE 26 GALVANIZED STRAP HANGER WITH HEMMED EDGES PER SURFACE MOUNT SIMILAR SMACNA FIGURE 3-10 . 4. FLEXIBLE AIR DUCT SHALL NOT EXCEED 8 FT. WHEN EXTENDED . ELBOW RADIUS SIZED FOR NO LESS THAN R / D = 1.0 . FLEXIBLE DUCT TAKEOFF DETAIL No Scale USE ONE OF AVAILABLE POWER INPUTS NOTE: AUDIBLE/VISIBLE ALARM 1 2 10 12 14 FOR WIRING OF AUXILIARY DEVICES EQUIVILENT TO SIMPLEX REFER TO MANUFACTURERS MODEL #4093 AT 120 VAC 24v FVAC INSTALLATION INSTRUCTIONS OR FOR STAND ALONE APPLICATIONS 220/240 CONTACT MANUFACTURER FOR COMPLIANCE N 9VAG CONTRACTOR TO PROVIDE CUT LOCATE IN NORMALLY OCCUPIED ED AREA OF PREMISES NEAR EACH AUXILIARY ALARM CONTROL CONTACTS SHEET PRIOR TO INSTALLATION THERMOSTAT OF CORRESPONDING UNIT s 16 n 18 19 zo NNO NNO vUU SYSTEM FAN HVAC AUXILIARY ALARM CONTROL CONTACTS CONTROL CONTROLFAN SHOWN IN STANDBY CONTACTS TRANSFER POWER OR DURING ALARM AS INDICATED BY THE ARROW THERMOSTAT FIRE ALARM PANEL INTERFACE CONTACTS a —J NO 9 CLOSEDEIN ONTACTS STANDBY s e n e s zo LOW VOLTAGE ALARM INITIATION CONTACTS AND ALARM CINTACTS Q SHOWN IN STANDBY CONTACTS TRANSFER OPEN WHILE DETECTOR No I o) No No U11 DURING ALARM AS INDICATED BY THE ARROW HEAD OR POWER IS U ® 5 m ( + > ALARM SIGNAL REMOVED AND DURING • 6 (- > AuxluARv Powell RESET AUXILIARY ALARM CONTROL CONTACTS ® 7 SHOWN IN STANDBY CONTACTS TRANSFER l9 ( + ) AUXILIARY POWER ® � DURING ALARM AS INDICATED BY THE ARROWS 10� TROUBLE POWER 15 CONTACTS DUCT DETECTOR EQUIVALENT ATA120 VAC HVAC FAN CONTROL WIRING A/C DUCT SMOKE DETECTOR -WIRING DETAIL FOR SYSTEM SHUT -DOWN LOW PRESSURE SUPPLY AIR DUCT WITH EXTERNAL DUCT INSULATION (SEE SPECS) SPIN -IN COLLAR WITH QUADRANT DAMPER AND 1" STAND-OFF BRACKET RIGID ROUND DUCT 1/2" STEEL CLAMP (OR PANDUIT STRAP) OVER INNER LINER OF PREINSULATED FLEX DUCT, WRAP DUCT TAPE OVER OUTER JACKET TO MAINTAIN INTEGRITY OF INSULATION. 12 GA. WIRE HANGER (SUPPORT MUST NOT DAMAGE DUCT OR CAUSE OUT OF ROUND SHAPE) BELL MOUTH TAKE -OFF MIN. 1 DUCT / DIAMETER STRAIGHT L RUN TO DIFFUSER QUANDRANT DAMPER WITH OPTIONAL STAND-OFF BRACKET. LOCATE QUANDRANT DAMPER HANDLE TO BE ACCESSIBLE 4" MIN. PRE -INSULATED FLEX DUCT NOT TO EXCEED 5' TYPICAL CEILING DIFFUSER CEILING (REFER TO ARCH. PLAN FOR TYPE) TYPICAL DUCT CONNECTION DETAIL No Scale NYARHO ARCHITECTURAL GROUP, INC. AA 002935 CHARLES O. A/YARKO, AIA AR 15759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn®nyarkoarchitects.com SEAL 4�CE ° ®� ® No.5 STATE OF !(� d AL dPBIfl800 CONSULTANT: PROJECT NAME AND LOCATION: ST. LUCIE ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: HVAC DETAILS PROJECT PHASE: 100% SUBMITTAL ISSUE DATE: 9/27/21 DRAWN BY: MARCOS REVIEWED BY: C.N. MISRAHI WORK ORDER NUMBER: SHEET NUMBER TYPICAL VERTICAL AIR UNIT DETAIL N.T.S. PROVIDE AUX. DRAIN W/ FLOAT SWITCH TO SHUT DN THE AHU IN CASE OF CONDENSATE OVERFLOW. mi GENERAL REQUIREMENTS A. DRAWINGS. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS, UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL, AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS, CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED. WHERE HEADROOM OR SPACE CONDITIONS APPEAR INADEQUATE, CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK. SITE CONDITIONS SHALL GOVERN THE EXACT LOCATION OF ALL ELECTRICAL EQUIPMENT, DEVICES, WIRING, CONDUIT, ETC. ONE COMPLETE SET OF DRAWINGS AND SPECIFICATIONS SHALL BE KEPT ON FILE AT THE SITE FOR THE SOLE USE OF MARKING AS -BUILT DATA. ALL CHANGES SHALL BE MARKED IN RED ON THESE PRINTS AS WORK PROGRESSES. PRIOR TO EACH REQUISITION FOR PAYMENT, AS -BUILT PRINTS SHALL BE BROUGHT UP TO DATE FOR ACCEPTANCE BY OWNER'S REPRESENTATIVE. THE COMPLETED SET OF AS -BUILT PRINTS SHALL BE DELIVERED TO THE ARCHITECT/ENGINEER PRIOR TO FINAL PAYMENT FOR INCORPORATION ONTO ORIGINALS. RISERS ARE DIAGRAMMATIC AND DON'T INTEND TO SHOW EVERY BEND REQUIRED FOR THE INSTALLATION, B. COORDINATION. CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND/OR CONNECT WITH APPROPRIATE SERVICES ALL ELECTRICAL ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, PLUMBING, AIR CONDITIONING SPRINKLER, INTERIOR DESIGN AND ELECTRICAL DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES, CONFLICTS, INTERFERENCES OR OMISSIONS OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ENGINEER IN AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. C. PERMITS. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, STATE SALES TAX, FEDERAL EXCISE TAX, ROYALTIES AND OTHER TAXES OR FEES AS REQUIRED FOR INSTALLATION OF A COMPLETE SYSTEM AS OUTLINED HEREIN AND AS SHOWN ON THE PLANS. THE CONTRACTOR SHALL SECURE ALL NECESSARY LICENSES AND INSURANCE. D. BASIS FOR BIDS. EQUIPMENT SPECIFIED SHALL BE ADHERED TO. HOWEVER, OWNER HAS FINAL DECISION ON THE TYPE AND QUALITY OF EQUIPMENT TO BE SUPPLIED. WITHIN 30-DAYS AFTER THE CONTRACT HAS BEEN EXECUTED, A FORMAL REQUEST FOR THE SUBSTITUTION OF PRODUCTS IN PLACE OF THOSE SPECIFIED WILL BE CONSIDERED, UNDER THE FOLLOWING CONDITIONS: THE REQUEST IS ACCOMPANIED BY COMPLETE DATA ON THE PROPOSED SUBSTITUTION SUBSTANTIATING COMPLIANCE WITH THE CONTRACT DOCUMENTS INCLUDING PRODUCT IDENTIFICATION AND DESCRIPTION, PERFORMANCE AND TEST DATA, REFERENCES AND SAMPLES WHERE APPLICABLE, AND AN ITEMIZED COMPARISON OF THE PROPOSED SUBSTITUTION WITH THE PRODUCTS SPECIFIED, WITH DATA RELATING TO CONTRACT TIME SCHEDULE, DESIGN AND AESTHETIC EFFECT WHERE APPLICABLE. THE REQUEST IS ACCOMPANIED BY ACCURATE COST DATA ON THE PROPOSED SUBSTITUTION IN COMPARISON WITH THE PRODUCT SPECIFIED, WHETHER OR NOT MODIFICATION OF THE CONTRACT SUM IS TO BE A CONSIDERATION. IF REDESIGN BY THE ARCHITECT OR HIS CONSULTANTS IS REQUIRED TO ACCOMMODATE AN ALTERNATE PRODUCT OR SYSTEM, ALL COSTS OF THIS REDESIGN SHALL BE BORNE BY THE CONTRACTOR REQUESTING THE CHANGE. IF ADDITIONAL WORK IS REQUIRED BY OTHER CONTRACTORS TO ACCOMMODATE AN ALTERNATE PRODUCT OR SYSTEM, ALL ADDITIONAL COSTS OF THIS WORK SHALL BE BORNE BY THE CONTRACTOR REQUESTING THE CHANGE. THE REQUEST SHALL BE ACCEPTED OR REJECTED SOLELY AT THE DISCRETION OF THE OWNER WITH ARCHITECT'S OR ENGINEER'S WRITTEN APPROVAL. E. CODES & STANDARDS. THE WORK PERFORMED UNDER DIVISION 16 SHALL COMPLY WITH THE LATEST EDITION AND REQUIREMENTS OF THE FOLLOWING: APPLICABLE LOCAL CODES AND ORDINANCES, NATIONAL ELECTRICAL CODE, AS AMENDED BY LOCAL CODE, ALL APPLICABLE FEDERAL AND STATE CODES, REGULATIONS AND STATUTES, APPLICABLE ENERGY CODE, OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), NATIONAL INC.ELECTRICA(UL) LMANUFACTURERS AMER CAN NATIONALS STANDATION ARDS UNDERWRITERS AMERICANS WIT ITHIES, DISABILITIES ACT (ADA). F. MATERIALS & EQUIPMENT. MATERIAL AND EQUIPMENT SHALL BE NEW, STANDARD, CURRENT PRODUCTS OF MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF SUCH EQUIPMENT, AND SHALL BE THE MANUFACTURER'S LATEST DESIGN. ALL MATERIALS SHALL BEAR THE LABEL OF THE UNDERWRITERS LABORATORY FOR THE INTENDED USE OR SHALL BE MATERIALS APPROVED BY THE CODE ENFORCING AUTHORITIES AND THE ARCHITECT. FOLLOW THE INSTALLATION DIRECTIONS AND RECOMMENDATIONS OF MATERIAL AND EQUIPMENT MANUFACTURERS. ALL WORK SHALL BE PERFORMED BY WORKERS SKILLED IN THEIR RESPECTIVE TRADES AND ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ALL WORK SHALL BE EXECUTED IN A NEAT AND WORKMANLIKE MANNER. INSTALL EQUIPMENT, INCLUDING SWITCHES, CONTROLLERS, FIXTURES AND TRANSFORMERS SUCH THAT REMOVAL OR REPLACEMENT MAY BE READILY ACCOMPLISHED WITHOUT DAMAGE TO EQUIPMENT OR FASTENERS. G. SUPPORTING DEVICES DEVICES, INCLUDING ANCHORS, FASTENERS, HANGERS AND SUPPORTS, SHALL BE OF A TYPE DESIGNED OR FABRICATED FOR THE PURPOSE, AND SHALL ADEQUATELY AND SAFELY SECURE THE MATERIAL AND EQUIPMENT AND PRESENT A NEAT APPEARANCE. USE DEVICES WITH CORROSION RESISTANT CHARACTERISTICS FOR THE ATMOSPHERIC CONDITIONS IN WHICH THEY ARE INSTALLED. H. RACEWAYS & BOXES. ROUTING OF RACEWAYS, INTERCONNECTING OUTLETS AND HOME -RUNS IS UP TO THE ELECTRICAL CONTRACTOR, BUT AFTER COMPLETION OF THE INSTALLATION, HE SHALL SUBMIT TO THE ENGINEER AS -BUILT DRAWINGS OF HIS WORK FOR FUTURE RECORD. DEVICE BOXES SHALL BE INSTALLED FLUSH, CONDUIT SHALL BE CONCEALED UNLESS OTHERWISE INDICATED. ALL CONDUCTORS SHALL BE IN CONDUIT. FOR UNDERGROUND/IN-SLAB LOCATIONS USE GALVANIZED RIGID STEEL (GRS) CONDUIT OR SCHEDULE 40 PVC CONDUIT WITH GROUND WIRE SIZED AS INDICATED OR REQUIRED BY N.E.C., STUB -UPS FROM UNDERGROUND/IN-SLAB PVC CONDUIT SHALL BE GRS. UNDERGROUND GRS SHALL BE COATED WITH TWO COATS OF BITUMASTIC #50 APPLIED WITHOUT THINNING. ALL SECTIONS OF METALLIC CONDUIT SYSTEM SHALL BE GROUNDED AND ELECTRICALLY CONTINUOUS. USE ELECTRICAL METALLIC TUBING (EMT) FOR INTERIOR CONCEALED WIRING AND ELSEWHERE AS PERMITTED BY THE N.E.C. USE FLEXIBLE METAL CONDUIT FOR FLEXIBLE CONNECTIONS IN ALL WET LOCATIONS. INSTALL A NYLON PULL -CORD IN ALL EMPTY RACEWAYS FOR FUTURE USE. SIZE ALL GUTTERS AND PULL -BOXES PER NEC 370 AND 374. ALL PULL AND JUNCTION BOXES SHALL REMAIN ACCESSIBLE AT ALL TIMES. ALL JUNCTION BOXES SHALL HAVE THE TYPE OF SYSTEM AND VOLTAGE OF CONTAINED CONDUCTORS STENCILED ON THE OUTSIDE OF THE BOX COVER. EXAMPLES: POWER 120/208 SOUND POWER 277/480 CONTROL 120 V T.V. FIRE ALARM INSTALL EXPOSED CONDUIT PARALLEL WITH OR AT RIGHT ANGLES TO THE BUILDING LINES. CONDUIT IN CONCRETE MEMBERS AND SLABS SHALL BE LOCATED SO AS NOT TO AFFECT THEIR STRUCTURAL STRENGTH. CONCEAL ALL CONDUIT IN WALLS, ABOVE CEILINGS, IN OR UNDER SLABS OR IN FURRING, EXCEPT IN MECHANICAL AND ELECTRICAL ROOMS. ROUTE RACEWAYS TO AVOID CONFLICTS WITH THE WORK OF OTHER TRADES. ALUMINUM CONDUIT WILL NOT BE PERMITTED. MINIMUM SIZE OUTLET BOX SHALL BE 4" SQUARE BY 1-1/2" DEEP UNLESS APPROVED OR INDICATED OTHERWISE. USE CAST METAL OUTLET BOXES WITH GASKETED COVERS FOR ALL EXTERIOR AND FOR ALL DAMP LOCATIONS. PROVIDE APPROVED FIRE STOPPING MATERIALS AT ALL CHASES TO PREVENT DRAFTS, AT PENETRATIONS INTO RATED SPACES, AND OTHER LOCATIONS AS REQUIRED BY CODES. PROVIDE CABLE SUPPORTS IN ACCORDANCE WITH NEC ARTICLE 300. PROVIDE EXPANSION FITTINGS IN CONDUIT RUNS CROSSING EXPANSION JOINTS IN THE STRUCTURE. I. CONDUCTORS. UNLESS OTHERWISE INDICATED, ALL CONDUCTORS ARE #12 IN 3/4" CONDUIT. ALL CONDUCTORS SHALL BE COPPER. ACCEPTABLE INSULATION TYPES ARE TW, THW, THHN, THWN, AND XHHW, WITH USES AS RESTRICTED BY THE NEC. AMPACITIES OF CONDUCTORS IS TO BE BASED ON ARTICLE 310 OF THE NEC WITH UL LIMITATIONS: 60 DEG. RATING FOR SIZES #14 THROUGH #1; 75 DEG. FOR #1/0 AND LARGER. CABLES 3/0 AND LARGER SHALL BE TERMINATED WITH PRESSURE CRIMP CONNECTORS. FOR 20 AMP BRANCH CIRCUITS GREATER THAN 100 FT. IN LENGTH, ONE WAY, UP TO 200 FT. USE #10 WIRE; OVER 200 FT., USE #8 WIRE. INCREASE CONDUIT SIZE AS REQUIRED FOR THE LARGER CONDUCTORS. THIS SUPERSEDES WIRE SIZES CALLED FOR ON THE DRAWINGS. CONDUCTORS SIZE #10 AND SMALLER SHALL HAVE INSULATION COLORED FOR PHASES A, B, C, AND N RESPECTIVELY AS FOLLOWS FOR 3 PHASE SYSTEM: 120/208 VOLTS: BLACK, RED, BLUE AND WHITE 277/480 VOLTS: BROWN, ORANGE, YELLOW AND GRAY ALL CONDUCTORS OF THE SAME PHASE IN PARALLELED FEEDERS OR SERVICES SHALL BE SOLIDLY CONNECTED TOGETHER AT THEIR TERMINATION IN A WIREWAY OR SPLICE BOX. MAKE CONDUCTOR LENGTH FOR PARALLEL FEEDERS IDENTICAL. THE PHASE DESIGNATION OF ALL SECONDARY CONDUCTORS SHALL BE THE SAME AND SHALL BE INDICATED IN OR ON ALL 3 PHASE OUTLETS, TRANSFORMERS, PANELBOARDS, AND DISCONNECT SWITCHES, AND THEY SHALL BE CONNECTED WITH UNIFORM PHASE SEQUENCE. MAINTAIN A, B, C PHASE RELATION LEFT TO RIGHT WHEN VIEWED FROM THE FRONT. TAG ALL FEEDER CONDUCTORS AND IDENTIFY MAJOR CONDUITS IN OR AT WIREWAYS, PANELS, PULL BOXES, SWITCHBOARDS, MOTOR CONTROLLERS, CABINETS AND SIMILAR ITEMS TO ASSIST IN FUTURE CIRCUIT TRACING. CONDUCTOR TAGS SHALL BE NONCONDUCTIVE, IDENTIFICATION SHALL CORRESPOND TO THE CONTRACT DOCUMENTS. COMMUNICATIONS, DATA, AND/OR WIRING WHICH IS NOT INSTALLED IN CONDUIT, AND WHICH IS ROUTED THROUGH ENVIRONMENTAL AIR SPACES, SHALL COMPLY WITH THE REQUIREMENTS OF NEC 300-22. PROVIDE TRAPEZE HANGER ASSEMBLY FOR PLENUM CABLES USING 3/8" DIAMETER HANGER ROD AND CHANNEL ASSEMBLY TO SUPPORT CABLE BUNDLES EVERY 4 FEET. ALL BUNDLES SHALL BE PROPERLY STRAPPED WITH SELF-LOCKING CABLE TIES. EXPOSED CABLES SHALL NOT LIE ON TOP OF CEILING TILES OR LUMINARIES. J. GROUNDING. END -TO -END LIGHTING FIXTURES SHALL BE CONTINUOUSLY BONDED. GROUNDING CONTACTS OF RECEPTACLES SHALL BE CONNECTED TO A SOLIDLY GROUNDED CONDUIT SYSTEM OR TO A SYSTEM GROUNDING CONDUCTOR (NOT THE SYSTEM NEUTRAL) BY A STRANDED COPPER WIRE NOT SMALLER THAN #12 AWG OR SHALL BE GROUNDED IN SOME OTHER APPROVED MANNER; THE RESISTANCE BETWEEN THE CONTACTS AND SERVICE GROUND SHALL NOT EXCEED 3 OHMS. ALL CIRCUITS SHALL HAVE AN EQUIPMENT GROUNDING CONDUCTOR. K. SAFETY SWITCHES/CIRCUIT BREAKER DISCONNECTS. SAFETY SWITCHES SHALL BE HEAVY DUTY TYPE KD, FUSIBLE, OR NON -FUSIBLE, WITH POLES, AMPERE, VOLTAGE AND HORSEPOWER RATINGS INDICATED AND SHALL HAVE SOLID NEUTRALS. LUGS SHALL BE U.L. LISTED FOR COPPER -ALUMINUM. ENCLOSURES FOR SAFETY SWITCHES SHALL BE NEMA-1, GENERAL PURPOSE, EXCEPT THAT SWITCHES INDICATED (WP) WEATHERPROOF, SHALL BE NEMA-3R ENCLOSURES WITH SUITABLE GASKETS AND BONDING MEANS. SWITCHES AND DISCONNECT SHALL BE AS MANUFACTURED BY SQUARE "D", OR APPROVED EQUAL. CIRCUIT BREAKER DISCONNECTS MAY BE USED IN LIEU OF SAFETY SWITCHES PROVIDING THEY COMPLY WITH THE SAFETY SWITCH REQUIREMENTS AND ARE SUPPLIED WITHIN THEIR RATINGS AND A SCHEDULE IS SUBMITTED FOR APPROVAL. L. MOLDED CASE CIRCUIT BREAKERS. CIRCUIT BREAKERS SHALL CONFORM TO APPLICABLE FEDERAL SPECIFICATIONS AND NEMA STANDARDS. CIRCUIT BREAKERS SHALL BE OF THE AMPERE RATING, VOLTAGE RATING, NUMBER OF POLES AND CLASS OR INTERRUPTING CAPACITY (I,C.) AS INDICATED. INTERRUPTING RATINGS ARE GIVEN IN ROOT MEAN SQUARE (RMS), SYMMETRICAL AMPERES BASED ON NEMA TEST PROCEDURES. LUGS AND TERMINALS SHALL BE U.L. APPROVED FOR COPPER -ALUMINUM. ACCESSORIES SHALL BE 120 VOLT. A.I.C. OF BREAKER TO BE INSTALLED ON EXIST. PANELS SHALL MATCH EXIST. EACH CIRCUIT BREAKER SHALL HAVE A TRIP UNIT FOR EACH POLE WITH ELEMENTS PROVIDING INVERSE TIME DELAY UNDER OVERLOAD CONDITIONS AND INSTANTANEOUS MAGNETIC TRIP FOR SHORT CIRCUIT PROTECTION UNLESS INDICATED AS NON -AUTOMATIC. TRIP ELEMENTS SHALL OPERATE A COMMON TRIP BAR TO OPEN ALL ELEMENTS. BREAKERS USED FOR SWITCHING SHALL BE RATED FOR SWITCHING DUTY. M. WIRING DEVICES. DEVICES SHALL BE AS SPECIFIED IN CONTRACT DOCUMENTS, INSTALL PLATES AND COVERS ON ALL OUTLETS. INSTALL ALL DEVICES UNIFORMLY IN EACH AREA. PLATES SHALL BE ALIGNED VERTICALLY AND HORIZONTALLY AND ALL EDGES SHALL BE IN FIRM CONTACT WITH SURROUNDING WALL FINISH. MOUNTING HEIGHTS (TO CENTER LINE OF BOX): GENERALLY MOUNT RECEPTACLES 18" AFF (ABOVE FINISHED FLOOR) UNLESS NOTED OTHERWISE, MOUNT SWITCHES AND DIMMERS AT 48" AFF. MOUNT OUTLETS OVER MIRRORS 8" HIGHER THAN MIRROR. MOUNT OUTLETS OVER COUNTERS AND CENTERED IN THE BACK SPLASH WHERE IT OCCURS; RECEPTACLE SHALL BE HORIZONTAL. ADJUST OUTLET HEIGHTS IN CERAMIC TILE WALLS TO BE ENTIRELY IN OR ENTIRELY OUT OF THE TILE. OUTLETS MAY BE HORIZONTAL TO MEET SPACE CONDITIONS. TEST EACH SOCKET OF EACH OUTLET WITH A DEVICE INTENDED FOR THE PURPOSE. ALL DEDICATED DATA EQUIPMENT BRANCH CIRCUITS SHALL FEED THIS TYPE OF EQUIPMENT ONLY AND SHALL CARRY A DEDICATED GROUNDING CONDUCTOR TO THE PANEL TO BE CONNECTED TO THE GROUNDING SYSTEM. NOW IN EFFECT FLORIDA BUILDING CODE 2020 EDITION & NEC 2017 EDITION. WORK IN EXISTING BUILDINGS THE NATURE OF THIS CONTRACT INVOLVES THE REMODELING OF EXISTING FACILITIES AND THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXACT LOCATION, QUANTITY, ACCESSIBILITY, ETC, OF EXISTING EQUIPMENT AND CONDITIONS AND COMPARE SAME WITH THE DRAWINGS AND SPECIFICATIONS AND SATISFY HIM/HERSELF OF THE CONDITIONS EXISTING PRIOR TO DELIVERING HIS/HER PROPOSAL. NO ADDITIONAL ALLOWANCE WILL BE MADE TO THE CONTRACTOR DUE TO HIS/HER NEGLECT OR FAILURE TO COMPLY WITH THE SPECIFIED REQUIREMENTS. IN EXISTING BUILDINGS, ALL ROOF AND SLAB PENETRATIONS MUST CONFORM TO LANDLORD'S STANDARD CRITERIA AND SHALL BE SUBJECT TO LANDLORD'S APPROVAL AS TO LOCATION AND CONSTRUCTION DETAILS. ROOFING AND/OR WEATHERPROOFING OF ANY INSTALLATION AND/OR PENETRATION MUST BE PERFORMED BY A CONTRACTOR AUTHORIZED BY THE LANDLORD. CONTRACTOR IS REQUIRED TO MAINTAIN FIRE RATING OF ALL WALL, FLOOR, OR ROOF PENETRATIONS, CONTRACTOR IS HEREBY NOTIFIED THAT WORK TO BE PERFORMED UNDER THIS CONTRACT REQUIRES MODIFICATIONS OF EXISTING ELECTRICAL INSTALLATION WHICH MAY BE IN USE WHICH WILL REQUIRE THAT ELECTRICAL POWER BE MAINTAINED. LIKEWISE, SOME WORK MAY NEED TO BE PERFORMER ON WEEK -ENDS OR AFTER HOURS. CONTRACTOR IS REQUIRED TO COORDINATE THESE REQUIREMENTS AND TAKE INTO CONSIDERATION IN HIS/HER BID ANY WORK WHICH MAY NEED TO BE PERFORMED ON WEEKENDS OR AFTER HOURS. CONNECT NEW SMOKE DETECTORS, FIRE ALARM SPEAKERS, PULL STATIONS, AND ANY OTHER FIRE ALARM SYSTEM PERIPHERAL EQUIPMENT TO THE EXISTING FIRE ALARM PANEL BY CONNECTING THE CIRCUITS AT THE NEAREST JUNCTION BOX OF THE SYSTEM. CONSULT WITH BUILDING FIRE ALARM CONTRACTOR TO ENSURE THAT NEW WORK DOES NOT AFFECT ANY EXISTING MAINTENANCE OR REPAIR CONTRACTS. NEW EQUIPMENT SHALL BE COMPATIBLE WITH EXISTING. VERIFY PRIOR TO BID. ANY WIRING INDICATED AS EXISTING IS BASED ON ORIGINAL CONTRACT DRAWINGS AND IS TO BE VERIFIED BY CONTRACTOR AT JOBSITE. IF REUSING EXISTING PANELS, CONTRACTOR IS TO REMOVE AND/OR REPLACE CIRCUIT BREAKERS IN EXISTING PANELS TO OBTAIN AMOUNT REQUIRED AS A MINIMUM PER PANEL SCHEDULE. ALL EXISTING EXCESS BREAKERS, IF ANY, TO REMAIN AS SPARES. DESIGNATED CIRCUIT NUMBERS SHOWN FOR ALL EXISTING PANELS IN BUILDING'S ELECTIRCAL ROOM(S) ARE FOR IDENTIFICATION ONLY. CONTRACTOR IS TO SHOW ON THE AS -BUILT DRAWINGS THE CIRCUITS ACTUALLY USED. IF REUSING EXISTING WIRING, ALL NEW BRANCH CIRCUIT BREAKERS SHALL MATCH EXISTING CONDUCTOR SIZE. IF CONDUCTOR SIZE IS LESS, REPLACE CONDUCTORS TO MATCH BREAKER. DEMOLITION REMOVE EXISTING RECEPTACLES, TELEPHONE, SWITCHES, AND ANY ELECTRICAL DEVICES IN WALLS TO BE DEMOLISHED. RELOCATE ANY OF THESE DEVICES AS INDICATED OR REQUIRED BY THE DRAWINGS. PROVIDE ARCHITECT WITH AS -BUILT DRAWINGS OF FINAL INSTALLATION FOR RECORD PURPOSES. CONTRACTOR IS NOTIFIED THAT NOT ALL EXISTING DEVICES MAY HAVE BEEN INDICATED ON THE DRAWINGS AND THAT SOME EXISTING ELECTRICAL DEVICES MAY NOT HAVE BEEN SHOWN IN THEIR ACTUAL LOCATION. CONTRACTOR IS REQUIRED TO VISIT SITE AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS PRIOR TO DETERMINING THE WORK THAT NEEDS TO BE ACCOMPLISHED AS PART OF HIS/HER BID. THE WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, CUTTING, EXTENDING, CONNECTING, REPAIRING, ADAPTING, AND OTHER WORK COINCIDENTAL HERETO, TOGETHER WITH SUCH TEMPORARY INSTALLATIONS AS MAY BE NECESSARY TO SATISFY THE DEMOLITION PROGRAM. APPROVAL SHALL BE SECURED FROM THE LANDLORD/ARCHITECT PRIOR TO CUTTING/DRILLING ANY STRUCTURAL SUPPORT. ALL BUILDING CONSTRUCTION AFFECTED BY THE REMOVAL, RELOCATION, INSTALLATION OF ANY PIECE OF EQUIPMENT SHALL BE REPAIRED AND FINISHED AS REQUIRED TO MATCH EXISTING CONDITIONS OR AS DIRECTED BY THE ARCHITECTURAL DRAWINGS, SPECIFICATIONS, OR OWNER'S REPRESENTATIVE, WHEN ELECTRICAL DEVICES ARE INSTALLED IN PARTITIONS OR CEILINGS TO BE REMOVED, THE ELECTRICAL CONTRACTOR SHALL DISCONNECT THEM UP TO THE NEXT OUTLET TO REMAIN OR BACK TO THE PANELBOARD. IF EXISTING TO REMAIN OUTLETS ARE FED THROUGH DEMOLISHED PARTITIONS OR CEILINGS, THE CIRCUIT SHALL BE REARRANGED TO MAINTAIN CIRCUIT CONTINUITY. WIRE SHALL BE REMOVED BACK TO SOURCE FROM INACCESSIBLE RACEWAYS NOT REUSED. INSTALL BLANK PLATES ON FLUSH OUTLETS NOT REUSED. PLATE COLOR SHALL MATCH ADJACENT SURFACE AS NEAR AS POSSIBLE IN FINISHED AREAS. ALL ELECTRICAL EQUIPMENT SHALL BE REMOVED FROM STRUCTURE TO BE REMOVED. ACCESSIBLE RACEWAYS, WIRES, BOXES, SWITCHES, AND OTHER ELECTRICAL ITEMS ASSOCIATED WITH THIS WORK SHALL BE REMOVED IF NOT REQUIRED FOR NEW EQUIPMENT TO CONTINUE IN SERVICE. ALL MATERIAL REMOVED SHALL BE DISPOSED OF AS DIRECTED BY OWNER. A,1 EXISTING FPL METER NEMA 3R 120/208v, 30, 4W. 4 #3/0 THWN-CU + 1 # 6 GND. IN ONE 2"C. 4 #3+ 1 #8 •) 4 #3+ 1 t8 IN 1-1/4"C. •' IN 1-1/4"C. NEW EXISTING EXISTING PANEL PANEL PANEL A.F.F ABOVE FINISH FLOOR A.F.G. ABOVE FINISH GRADE IWH INSTANT WATER HEATER G.F.I. GROUND FAULT INTERRUPTER U/C UNDERCOUNTER MTD. MOUNTED U.O.N. UNLESS OTHERWISE NOTED WT WATERTIGHT WR WATER RESISTANT XMER. TRANSFORMER TEL. TELEPHONE PNL. PANEL TYP, TYPICAL LTG. LIGHTING FIN. FINISH CU. COPPER GIRD. GROUND FLUOR. FLUORESCENT EMERG. EMERGENCY FPL FLORIDA POWER & LIGHT U.G. UNDERGROUND LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURER CATALOG NUMBER MPS VOLTS MOIJN11NG REMARKS 2'x4' LED PANEL WESTGATE TGL-2X4-4OW LED 120 RECESSED Al 2'x4' LED PANEL WESTGATE TGL•-2X4-4OW LED 120 RECESSED - EXIT SIGN SIMKAR SELBIGW INCLUDED 120 WALL - C 2'x2' LED PANEL WESTGATE TGI_-2X2-40W LED 120 RECESSED - WITH 90MIN. C1 2'x2' LED PANEL WESTGATE TGL-2X2-40W LED 120 RECESSED BATTERY BACKUP I 1. LIGHT FIXTURES CAN 13E REPLACED BY EQUAL UL LISTED WITH PREVIOUS APPROVALOF RECORD. 2. PROVIDE i MlNUFACTURER RECOMMENDATION IN ALL FIXTU,, C C W TYPE: SCARE' D MAIN BUS:_225k_. SERVICE: 120/208V• 3PH, 4W TI G NEUTRAL: -FULL MOUNTING: SURFACE MAINS: MCB 200A POLES: 42 A.I.0 10,000A OEM K.VA NO OEM K.VA TRIP POLE CON DUIT WIRE REMARKS CKT NO CKT NO REMARKS WIIRE 40 DEM K.VA OEM K.VA 0.2 0.2 20-1 1/2 12 UGHTING CONTROL 1 2 OUTDOOR LTG. 12 1/2 20-1 1.0 1.2 0.6 0.6 20-1 1/2 12 RECEPTACLES 3 4 1AIR COMPRESSOR 8 3/4 40-2 5.2 5.2 1.2 1.2 20-1 1/2 12 ICE MACHINE 5 6 0.2 0.2 20-1 1/2 12 1 REC. PHONE 7 8 1.0 1.0 20-1 1/2 12 PRINTER 9 10 d EXISTING PANEL "8" 3 -1/4 100-3 14.6 14.6 1.0 1.0 20-1 1/2 12 WORK TABLE 11 12 -_ 0.8 0.8 20-1 1/2 12 -...- -- REC, K AREA-2 13 14 LIGHTING/MECH ROOM 12 1/2 20-1 0.8 1.0 1 -- 1.0 1.0 20-1 1/2 12 - WORK TABLE 15 16 --------- LIGHTING WORK AREA-1 12 1/2 20-1 0.8 1.0 1 1.0 1.0 20-1 1/2 12 WORK TABLE 171. 18 UGHTING CCTV ROOM 12 1/2 20-1 0.8 1.0 1 1.3 1.3 20-1 1/2 12 RECEPT. OFFICE-2 19 20 UGHTING WORK AREA-2 12 1/2 20-1 0.8 1.0 1.2 1.2 20-1 1/2 12 RECEPT, WORK AREA-1 21 22 RECEPT. OFFICE-1 12 1/2 20-1 1.3 1.3 1.0 1.0 20-1 1/2 12 COPIER CCTV ROOM 23 24 CONVENIENCE RECEIPT. 12 1/2 20-1 0.8 0.8 1.2 1.2 20-1 1/2 12 IT RACK ROOM 25 26 RECEPT. CCTV ROOM 12 1/2 20-1 0.8 0.8 0.6 0.6 20-1 1/2 12 RECEPT. CCTV ROOM 27 28 RECEIPT. CCTV ROOM 12 1/2 20-1 0.8 0.8 29 30 25.6 41.6 100-3 -1/4 3 NEW PANEL •C" 31 32 POWER STRIP 12 1/2 20-3 1.6 1.6 33 34 0.8 0.8 20-1 1/2 12 RECEIPT. WORK AREA-1 35 1 361 SPACE ---- SPACE -- 37 1 381 SPACE SPACE 39 40 SPAN SPACE 41 42 SPACE 38.7 54.7 29.3 30.3 TOTAL CONNECTED LOAD = 84.00 KVA TOTAL DEMAND LOAD = 69.00 KVA IL = 69,000 t 360 a 191.6 A 1 LOADS UNDER SCOPE OF WORK, PROVIDE ISOLATED GROUND. 191 TYPE: _SQUARE' D - MAIN! BUS: SERVICE: 120/208V. 3PH. 4W W) NEUTRAL: FU MOUNTING: SURFACE MAINS: MILO POLES: 24 A.I.0 10 OOOA DEM NO DEM TRIP CON WIRE REMARKS CKT CKT �1140 REMARKS VARE CON TRIP NO DEM DEM K.VA K.VA POLE DUIT NO DUrrj POLE K.VA K.VA 1 2 MU-2 6 3/4 60-2 9.3 9.3 14.0 14.0 50-3 3/4 8 AHU-1 3 4 _ 5 6ICU-2 8 3/4 50-2 6.0 - 7 8 - 10.0 35-3 3/4 8 CU-1 9 10 MINISPUT 12 1/2 20-2 2.3 2.3 11 12 SPACE 13 14 SPACE ----- SPACE 15 16 SPACE - SPACE 17 18 SPACE, SPACE 19 20 SPACE SPACE 21 22 SPACE SPACE 23 24 SPACE 14.0 24.0 17.6 11.6 TOTAL CONNECTED LOAD = 41.60 KVA TOTAL DEMAND LOAD ! 2.60 KVA I L = 25,600 # 360 = 71.1 A 1 LOADS UNDER SCOPE OF WORK. !J 7 J AA 002935 CHARLE S 0. NVARK0, A14 AR 16759 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL: (305) 820-3555 / FAX: (305) 820-3210 EMAIL: cn@nyarkoarchitects.com SEAL °°°p0�p0�QOpO69�p^p 6U000ODOORpOPOQp�pppppp N o U No. 00 488 N o _ S OF e R 1 Opppppppp4e �oOD' V AO U oogp9��0p°�°p0O CARLOS M. 8 "C RI 01 IEZ FE-55488 CONSULTANT. PROJECT NAME AND LOCATION: ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: PROJECT PHASE: 100% SUBMITTAL ISSUE DATE: 8/24/21 DRAWN BY: O.V. T REVIEWED BY: C.N. WORK ORDER NUMBER: ---- SHEET NUMBER E-1.V i ■ w U. CONC. PAVING _ CONC. i A4,6 I PAVING 126Q� I I I� I Aq A24 A24 PAANNEL •C' At E)USTINg PANEL A' A15 Att A24 ,, PROPOSED WORK AREA - 2 A24 GFI C6 8 .60 i i ---- - -------_ o cu-z� 0 CUI'$ ON 11 4 ❑ A13 A13 CONIC. PAD o Q� 46 cu-1 A35 o AHU-2 Jv Li _ 2 C7,9,11 �CZ4 AHU-1 ACI EXISTING MECH/STORAGE ROOM Ez EXIST. 4 ATwi°0'SA.F F. PARKING A30„A32,A34 SPACE Ali PROPOSED WORK AREA- 1 Alt IL CONC. PAVING PAVING A21 A28' - A28 A21 A21 A21 A2 CCTV A19 A22 CAMERA +� OFFICE-2 OFFICE-1 COVER A AN 26 3-A.F.F.+36'A.F.F. A4 Al A � RACK --._..--- - ---- ROOM MINISPLIT } AHU-3 + O.F."s g C1O.12 i F F - _ C10,12 _�M NSPLIT CU-3 fo ON CONCRETE PAD I EXISTING AREA (N.I.C.) PAVING CONC. PAVING EL PLAIN. 0 2' 4' 8' 16' 1 /8"=1 —0" SCALE CONTROL Y P40TOCE mVP ------------ rum A� Alp At0 A20 ; i � I i rA20 TA"20 PA20 ---- ---- I i i ----------------- A20 A 20 At6 rA16 i ... ; ; i p� A16 PA16 - I rAl tAls w' EXISTING C0NTR0I. 8Y PHOTOCELL 1 -- ----------------- EXISTING A� OCELL COOTTROL BY OCELLAZ A16 A16 18 1 '4 (V '-- A14 A14' 1 -18 ® i ; A141 18 18 L lu" H T I N G* ' " P L A IN. 0 2' 4' 6' 16' - --- 1 /8"--1 '-0" SCALE l PARKING LOT LIGHTING IS EXISTING TO REMAIN. 2. OCCUPANCY SENSORS SHALL • MINUTES OF ALL OCCUPANTS 3. EGRESS ILLUMINATION MEETS MINIMUM 1 FC ASS PER • • 4. ALL MARKED RECEPTACLES (*) SHALL BE CONTROLLED THRU ASTRONOMIC TIMER SWITCH SET TO TURN THE RECEPTACLES OFF WITHIN 20 MINUTES AFTER AREA IS UNOCCUPIED. ALL CONTROLLED RECEPTACLES TO VISUALLY DIFFERENTIATE -• ROLLED RECEPTACLES. ASHRAE 90.1 5. EXITS SIGNS & EMERGENCY LIGHTS TO COMPLY NOTE:J SYMBOLSNOT ALL .;.. , USTED PROJECT.APPLY TO THIS 0, DOCUMENTS FOR SCOPE OF WORK. ELECTRICAL SYMBOL LEGEND 0 LIGHTING FIXTURE TYPE & WALL MOUNTED LIGHT FIXTURE 13 RECESSED 2'x2' LED LIGHT FIXTURE, RECESSED 2'x2' LED LIGHT FIXTURE WITH BATTERY BACKUP. SURFACE MOUNTED LED LIGHT FIXTURE. SURFACE MOUNTED LED LIGHT FIXTURE WITH BATTERY BACKUP. ----- LED COVE LIGHTING EXIT LIGHT - DIRECTIONAL ARROWS AS INDICATED EMERGENCY LIGHTING UNIT WITH BATTERY BACKUP. EXIT SIGN / EMERGENCY LIGHT COMBINATION UNIT. WITH BATTERY BACKUP. DUPLEX RECEIPT. - NEMA 5-20R (18" A.F.F.TO CENTER) ocm DUPLEX RECEIPT. CEILING MOUNTED. ot OUADRUPLEX RECEPT. - NEMA 5-20R. SINGLE RECEPT. - NEMA 5-20R (18" A.F.F.TO CENTER) SPECIAL RECEIPT. - RATED AS NOTED, MASTER CONTROL SWITCH. TO CONTROL ALL PERMANENTLY INSTALLED LUMINAIRES & SWITCHED RECEPTACLES IN SLEEPING UNITS, AS PER FBC-E C405.2.3.3. POWER & DATA SUPPLY VIA POWER POLE. TV CAN OUTLET, COORIDNATE MOUNTING HIGH. FUSIBLE DISCONNECT SWITCH POLES, AMPS AND FUSES AS SHOWN NF INDICATES NON -FUSED MOTOR (1 PHASE) ,1 JUNCTION BOX SINGLE POLE SWITCH - 20 AMP (48" A.F.F.TO CENTER) 3 THREE WAY SWITCH (48" A.F.F. TO CENTER) D DIMMER SWITCH (48" A.F.F. TO CENTER) TWO POLES SWITCH. SINGLE POLE SWITCH - W/OCCUPANCY SENSOR (48" A.F.F.TO CENTER) ELECTRICAL METER PANELBOARD (6'-0" AFF TO TOP) DATA/TELEPHONE OUTLET L:J TIMER DL LIGHTING CONTACTOR !.� DOOR CALL LIGHT. HEARING IMPAIRED ROOMS. sue- PUSH BUTTON FOR DOOR CALL LIGHT. OCCUPANCY SENSOR CONTROL DEVICE. cos) (LIGHTING CONTROL). ® SMOKE DETECTORS TO BE MULTIPLE STATIONS POWERED 120V WITH BATTERY BACK UP AND A MINIMUM OF 36 INCHES FROM ANY AC GRILLES, Y PLAN AA 002935 CHARLES O. NVARK0, AL4 AR 157aP 5931 NW 173 DRIVE, SUITE 2, MIAMI, FL 33015 TEL (305) 820-3555 / FAX: (305) 820-3210 EMAIL: ennyarkoarchltects.com SEAL CONSULTANT: PROJECT NAME AND LOCATION: OFFICES ka, � M�i T1 I ADDRESS: 3158 WILL FEE ROAD, FORT PIERCE, FL 34982 REVISIONS: NO. DATE DESCRIPTION: DRAWING TITLE: 4 PROJECT PHASE: 100% SUBMrV44.L ISSUE DATE_ 8! 1 DRAWN BY: O.V. I REVI E BY: C.N. WORK ORDER NUMBER: ---- SHEET NUMBER E0 ■