Loading...
HomeMy WebLinkAboutAPPROVED 3200 HR FL15814.1BCIS Home 1 Log In f User Registration 1 Hot Topics I Submit Surcharge { Stats & Facts ; Publications Contact Us. BCIS Site Map ? Links d' bFdda Product Approval pr USER: Public User l AD Product Approval Menu > Product or Aoylication Search > Application List > Application Detail FL.# FL15814-R5 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext291 jlathrop@cws.cc Authorized Signature Jay Lathrop jlathrop@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Category Windows Subcategory Horizontal Slider Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A. Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2028 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL15814 R5 COI EvalReport774D.pdf Referenced Standard and Year (of Standard) Standard Year AAMA/ W DMA/CSA/101/I. S.2/A440 2008 ASTM E1886-13a 2013 ASTM E1996 2017 PA TAS 201/202/203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15814 R5 Equiv 3200 Equiyalency pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/27/2020 Date Validated 08/30/2020 Date Pending FBC Approval 09/18/2020 Date Approved 12/15/2020 summary of Products FL # ModelI Number or Name Description 15814.1 HS-3200 HS-3200, Aluminum Horizontal Slider, Impact. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15814 R5 II CWS-774D.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A, Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact, see installation drawings for DP FL15814 R5 AE EvalReport774D.pdf and sizes. Glass complies with ASTM E1300. Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. Privacy. Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee. under Chapter 455, F.S., please click here . Product Approval Accepts: MMME912 Credit Card Safe URNER ENGINEERING & CONSULTING. INC. 2428 Old Natchez Trace Trail Camden, TN 38320 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 774D August 18, 2020 Product Description: Series 3200 (formerly 7700) Aluminum Horizontal Slider Window, LM Impact, max. unit sizes of 74" x 64" DP60 XO or OX, and 112" x 64" DP50 XOX 1/4-1/2-1/4 Manufacturer: Custom Window Systems, Inc. 1900 SW 441h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 7th Edition (2020) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, PE, at 2428 Old Natchez Trc Trl, Camden, TN 2) Approval drawing CWS-774D, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3817-1, -lA, -2, and -2A, and NCTL-210-4000-06, -6A, -07, and -7A, from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E., and test reports CWS-004-02-05 and CWS-005-02-03 from PRI Construction Materials Technologies, Tampa, FL signed and sealed by Zachary Priest, with testing performed: TAS 201/202/203 94, AAMA/WDMA/CSA 101/I.S.2/A440-08, ASTM E 1886-02/04/05, and ASTM E 1996-02/04/06/09 4) Supplemental Calcs. to support CWS-774D, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-774D. Limitations of Use: This product: • May be used up to sizes indicated in CWS-774D, with glass types, design pressures, and max. glass daylight sizes as shown in CWS-774D • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • I.G. glass with annealed outboard lite may not be used above 30 It from grade in HVHZ • Requires Kuraray Butacite PVB Interlayer per Miami -Dade NOA 19-0305.02' • Requires 6063-T6 aluminum extrusions per CWS-774D t I have evaluated the material in this NOA and find that it complies with the requirements of the 7`h Edition (2020) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. �Ny�p A tt1Z. Lucas Turner Na 58201 2020.08.21 * _ 08/18/2020 10:17:57 1W� Lucas A. Turner P.E. -05'00' 0 -6 STATE OF FL PE #58201 P. l�11i11ii 65 114" FLANGE 6! FI H' --751/4" FLANGE WIDTH-- ---74" UNITWIDTH 13/16" SASH WIDTH A 331/16" 331/16" -i - GLASS DLO GLASS DLO I HORIZONTAL SLIDER - IMPACT 281/16" E 64" B 57 1l16" 58 7W I B UN IT GLASS GLASS HEGHT DLO I DLO X O 60 9/16" SASH I HEIGHT A OX or OX 6E FI H —db 1/2" FLANGE WIDTH aSH WIDTH 851/4" UNIT WIDTH D 235116" 251/2" I 1/4" GLASS GLASS ANGE DLO DLO IGHT - - 64" E 571/16" GLASS I 587/8" GLASS I I I E UNIT DLO DLO HEIGHT X 0 x 60 9/ SAS] p a HEIG 113 1/4" FLANGE WIDTH 112" UNIT WIDTH - --28 1116" SASH WIDTH A 1/4" 23 5/16" - 52 1/4" - B ANGE TIGHT GLASS DLO GLASS DLO r 7 64" UNIT HEGHT 57 1/16" GLASS DLO 58 GLASS DLO 718" I 6091 )( Q )(� SASI HEIG 114-1/2-114 TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS _1 GLAZING DETAILS.................................2 SECTION VIEWS, .......... 3-4 EXTRUSIONS & BOM .............................5 ANCHOR SCHEDULE & NOTES........._6 INSTALLATION DETAILS.......................7 65 1/4" FLANGE HEIGHT 6M1" C UNIT 16" 1 HT 1l3-1/3-113 D ®� —55 3/4" FLANGE WIDTH —541/2" UNIT WIDTH --7-2111116" SASH WIDTH 23 5/16"1 ( 23 5/16" GLASS GLASS DLO DLO GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND WINDOW SYSTEMS MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE 190o SW 44TH AVE. HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED OCALA, FLORIDA 34474 WWW.CWS.CC FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. 2. GLAZING DETAILS: (SEE SHEET 2) 3200 ALUM. HORZ. SLIDERIMPACT 3. CONFIGURATIONS: "OX", "XO", "XOX" 4. DESIGN PRESSURES: -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE ¢ Z a AND GLASS TABLES ASTM E-1300-04e01/09. Z o O)WO -POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, z w uj o ¢ O WATER INFILTRATION TEST PRESSURE, AND GLASS w Z O Z x = I_ TABLES ASTM E-1300-04e01/09, 0 F 0w z�� 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT o 0 � 0 a � I- nw. BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE o Z - = Z Z � m SHEET 7 FOR INSTALLATION DETAIL. WIND LOAD 6 Z ¢ O Z O ui Z 0- ~ - M O I'- Z DURATION FACTOR Cd=1.6 WAS USED FOR WOOD Y w O ¢3:Ow-=O- HT ANCHOR CALCULATIONS. < mg } I._ v t Z vi W U)0w 6. PRODUCTS APPROVED FOR IMPACT RESISTANCE. (If LL U)w � w O -r V) F SHUTTERS ARE NOT REQUIRED. a0 w H 0 w 0 > w� 7. ALL FRAMES AND VENTS ARE SCREWED TOGETHER, a w , D- w 2' a SMALL JOINT SEALANT USED AT ALL FRAME JOINTS. 8. SERIES / MODEL DESIGNATION HS-3200 (A.K.A. HS-7700) A71��777j�' 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERABLE SASH, O = FIXED SASH 10. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS. =� N$8•�01 u 11. WEEP SLOTS = 1/4" x 1" LOCATED 6" FROM BOTH ENDS. 0 >STA7EOF i �i t4s �OIIA�' .i Lucas Turner 2020.08.21 571/16" 58 7/8" 10:22:15 GLASS GLASS 8/18/2020 DLO DLO -05,00, 60 9/16" LUCAS A. TURNER, P.E. X 0 SASH HEIGHT FL PE # 58201 2428 Old Natchez Trc Td — - - Camden, TN 38320 CI XO PH. 941-380-1574 SHEET DESCRIPTION: MAX SURE DESIGRAT CONFIG. ENIT NG IMPACT RATING XO w/SIDE LATCH 54-1/2" x 64" +/- 50 PSF LARGE MISSILE IMPACT XO 74" x 64" +/- 60 PSF XOX 1/3 1/3 1/3 85-1/4" x 64" 50 PSF XOX 1/4 1 /2 1/4 1 112" x 64" GENERAL NOTES AND ELEVATIONS DRAWN BY: DATE: ADE 06/01/12 DWG#: REV.: CWS-774 D SCALE: SHEET 1:20 1 OF 7 5/16" OVERALL - 118" ANNEALED -.090 DUPONT PVB INTERLAYER -1/8" ANNEALED LEX 552 or ECT GLAZE "H" GLASS TYPE A - SASH BITE 718" OVERALL 118" ANNEALED 7/16" AIRSPACE 5/16" LAMINATED 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 1/8" ANNEALED QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER t� SIKAFLEX 552 or I PURFECT GLAZE "H" 3/4" GLASS BITE GLASS TYPE C - SASH 5/16" OVERALL 7/16" OVERALL �"""' gom WINDOW SYSTEMS ���%�%� —1/8" ANNEALED - 3/16" ANNEALED 1900 SW 44TH AVE. OCALA, FLORIDA 34474 090 DUPONT PVB INTERLAYER .105 DUPONT PVB INTERLAYER WWW.CWS.CC —1/8" ANNEALED 3/16" ANNEALED SIKAFLEX 552 or 15 SIKAFLEX 552 or 3200 ALUM. 15 PURFECT GLAZE "H" PURFECT GLAZE "H" HORZ. SLIDER { IMPACT 314" GLASS BITE 3/4" GLASS BITE ¢ Z � ¢ z � �1 30 I- 0w0 wwpo Z WJ0 13.. w Z0Z o �z� LLo aw�z0w3:E Z z=�¢Q�wp0 O OF-OF'drZai C jZr2 } Q�pw-mOz GLASS TYPE A - FIXED XO GLASS TYPE B - FIXED XOX w F } 0 O w OLLU WU)0 JrgW D 00 wr0 Q. a: a I- (L O W N a 718" OVERALL 7/8" OVERALL 118" ANNEALED 3l16" ANNEALED J1111111/11op$A.T 1j1/��'' 7/16" AIRSPACE 1/4" AIRSPACE 5/16" LAMINATED 7l16" LAMINATED No. 58201 1/8" ANNEALED 3/16" ANNEALED* f` .090 DUPONT PVB INTERLAYER .105 DUPONT PVB INTERLAYER STATE OF *yOpF 1/8" ANNEALED 3116" ANNEALED NA1�������`�� QUANEX DURASEAL or, QUANEX DURASEAL or, CARDINAL XL EDGE or, CARDINAL XL EDGE or, KODISPACE 4SG TPS KODISPACE 4SG TPS I.G. SPACER I.G. SPACER 15 SIKAFLEX 552 or 15� SIKAFLEX 552 or 8H8/2020 PURFECT GLAZE"H" PURFECT GLAZE"H" LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Td 3/4" GLASS BITE 314" GLASS BITE Camden, TN 38320 1 41Lu PH.941-380-1574 13 " "' 13 SHEET DESCRIPTION: "I GLAZING DETAILS DRAWN BY: DATE: ADE 06/01/12 DWG#: REV.: GLASS TYPE C - FIXED XO GLASS TYPE D - FIXED XOX CWS-774 D SETTING BLOCKS PER FBC 2411.3.3.1 SCALE: SHEET1:1 20F7 INTERIOR WINDOW SYSTEPIS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 4 14 3 2 22 17 14 37 3200 ALUM. HORZ. SLIDER I M PACT I- Z � ¢z� ow0 �Wop Ju Z W W J ZOZ_ xrzw 8 "N—' I 11 ¢-w�z�32= 9 „ f Z O Z=iCKWOO 0I--0d<MF-X �1 �29 28 v Z Urn�Zal-tnn. Z—s ZFDy 00 DU— } i'�� Of QZw10200? 2 1- 34 8 9 38 33 9 23 1 26 40 w O O tr y p w w 40 -- EE Z Lu 0 J o SECTION VIEW B-B O w~ 0 w x> INTERIOR a I•- Q. X a 16 A. iU ii,��i/i kwycp / vJ '� ..��� v%C. * 16 19 = No. 58209 yt� 1Y- _=�1 =70 Z* AY- aTATE OF CJ 8/18/2020 21 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH.941-380-1574 (34 SHEET DESCRIPTION: 34 38 2s SECTION VIEWS SECTION VIEW A -A XO SECTION VIEW C-C DRAWN BY: DATE: SIDE LATCH OPTION ADE 06/01/12 SIZE AND DP RESTRICTED, SEE SHEET 1 DWG#: REV.: ITEMS NOT SHOW FOR CLARITY: CWS-774 D 5, 6, 10, 12, 15, 18,24 SCALE: SHEET 1:1.33 3 OF 7 INTERIOR � 4 14 3 40 2 6 14 4 WINDOW SYSTEMS 1900 SW 44TH AVE, OCALA, FLORIDA 34474 WWW.CWS.CC 3200 ALUM. HORZ. SLIDER I M PACT - - c Z 3: ¢Z� - -- WoCi 0 ZOZ o '-Zm U. Z FW§ZH3y^Z= Z=8QaWpp U 0w H-Zd. 1-0D_ �34 9 38 33� 29 29 3 26 1 30 40 30 1 I29 29 8 34 Z �—Z O Z U ci Z (25 U E9 �¢pFt FZZ SECTION E-E w pO OwU)iwD- n Wp _n F- ~aL 8 woNK_ l w 9 � n H 28 30' �;�'� 2-9 111111UfIll/// A. G `\\\\``�V� �* 1k' 1 ?y No. 58201 INTERIOR Ex zit W G STATE OF 040 C16 19 8/18/2020 30 = _� r1 i _oil 27 _ 32 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: �38 SECTION VIEWS XOX (21) DRAWNBY: DATE: ADE 06/01/12 DWG#: REV.: CWS-774 D �4 ITEMS NOT SHOW FOR CLARITY: SCALE; SHEET SECTION VIEW D-D 5, 6, 10, 12, 15, 18, 24 1:1.33 4 OF 7 PARTS LIST DESCRIPTION MATERIp FIXED MEETING RAIL ALUMINU SASH MTG. RAIL, SASH ALUMINU SASH LIFT RAIL, SASH ALUMINU WSTP, (.300 x .187back, Bulb ) SCREEN LIFT STEEL SCREEN SPRING STEEL LOCK SPRING STEEL WSTP (.210 x .187back) SCREEN FRAME (5/16") ROLLFOR ROUND SPLINE (.155) WSTP (.270 x .187back) SCREEN CORNER KEY NYLON SETTING BLOCK(1/8" x 3/8" x 2") RUBBEF OPEN CELL PAD (black) HOLT MELT WSTP, (.290 X.187) BULB #8 X5/8" PHIL FLAT WHT STEEL SCREEN CLOTH ROLLER ASSEMBLY NYLON #8 X 1 PAN PHIL W/ 1/4" LEAD STEEL WEEP HOLE COVER NYLON SASH MTG RAIL LOCK NYLON ., SASH D-5/16 D-7/16 LATCH 1 38 1 IWSTP (.530 x .187back) ( I 1 7116" 1/2" —1/ 6' 2 ROLLER TRACK - 1959 7/8" 26 1/8" REINF. - 1935 -- 2 5/8" F� 25 2 3/16" 31 1/16" HEAD -1933 — 3 1/16" 34 2 7/8" 1/16" LOCK JAMB - 1962 2 3/8" 3 2 Ld 1/16" SASH LIFT RAIL - 1947 15/16" -{3� 1" L 1/16" SCREEN CATCH -1960 LINE ITEMS NOT USED: 39 NOTE: ALUMINUM PROFILES ARE 6063-T6 UNLES OTHERWISE NOTED. SILL, BOTTOM - 1966 1 15116" 37 2 11116" LLI 1l16" FIXED JAMB - 1957 [--2 1 /2" 2 2 5/16" 1/16" SASH MTG RAIL - 1946 15116" 9/16" 27 r 1/16" SCREEN TSUPPORT -1936 1 5/16" wr 3 5/16"L Li 36 -1/16" SILL, TOP - 1967 FIXED MTG RAIL - 1934 1 1 /8" - 28 1 3/4" 1 �'=A_ 1/16" SASH TOP/BTM RAIL - 1939 13/16" 31 1 114" 1116" SPRING E LATCH - 1956 3/4"' 3/16" - 41 7/y8" 1/16" J PVC 7/8" GLAZEBEAD - 5523 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC I 1II III 1 4' 3200 ALUM. FRAME CORNER CONSTRUCTION HORZ" SLIDER IMPACT 20 \\ c Z Z ¢Z3: W. O _<W�W w IL ZOZ KZF- Hw ZI-3:g= Z O Z=2¢wWOO OF-Wa. 0- SASH CORNER CONSTRUCTION Q O Z 0 ✓n Z O F--u. 00LL0 Q�Ow��O- ry I¢- }� �i02 �- E zma`Omoo�w 20 0 S~w WORN a C�a MEETING RAIL ATTACHMENT SMALLJOINTSEAM SEALANT 3/4" -{29� 1 1/16" 5/16" GLAZEBEAD - 1941 3/4" 30 1" 7/16" GLAZEBEAD - 1949 per,''''/ `* =-u No.58201 0 E!x Z* tl �+Iti STATE OF 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH.941-380-1574 BOM AND EXTRUSIONS ADE 06/01/12 ✓G #: REV.: CWS-774 D ALE' SHEET 1:2 5 OF 7 14" MAX. O.C. (TYP.)- -{ 6" MAX. 6" MAX. (TYP.) 18" MAX. OJ (TYP) NOTES: rt ANCHOR LAYOUT - (FLANGE) 6" MAX (TYP 6" MAX (TYP 18" INSTALLATION MAX ) ANCHORS TYP. ANCHOR LAYOUT - (FLANGE) IOTE 2 INSTALLATION ANCHORS TYP. 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD, 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4", USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED, 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 7. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 7. aubm WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3200 ALUM. HORZ. SLIDER IMPACT a z 3 ¢z wWO<� wZ J-zW zOzwF U. _�M I—WZ3:=z zx�<wwpO 0 0ccooOZa-Prn5- m z—wnZZF-nw 2 F-tO— w OcowInaWinw W v1 W J a _~W W�W�n a a w H `/�,�cEttipti No. 58201 STATE OF ..R�ORICF..at 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Td Camden, TN 38320 PH.941-380-1574 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. SHEET DESCRIPTION: ANCHOR SCHEDULE AND', NOTES 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR SOLID CONCRETE, 3-9116" FOR CMU, 1" FOR WOOD AND METAL. DRAWN BY: --` DATE: 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 7. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. ADE 06/01/12 DWG #: 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) CWS-774 DscALE: SHEET 1:20 6 OF 7 TYPICAL HEAD ANCHORAGE MIN. EDGE DIST. SEE TABLE 1 MIN. EMBEDMENT WINDOW SYSTEMS SUBSTRATE BY OTHERS SEE TABLE 1 1900 SW 44TH AVE. SEE TABLE 1 INTERIOR 114" MAX. SHIM OCALA, FLORIDA 34474 WWW.CWS.CC PERIMETER SEALANT MIN. EMBEDMENT BYINSTALLER INSIDE AND OUT SEE TABLE 1 MIN. EDGE DIST. 3200 ALUM" SEE TABLE 1 HORZ. SLIDER SEALANT BEHIND FLANGE BYINSTALLER INSTALLATION ANCHOR —� IMPACT 1/4" MAX. SHIM SEE TABLE 1 Q Z QZ� O Z00Z §E}Oof�m IN lL F-W ZF3'2=TERIOR INSTALLATION ANCHOR-- SEE TABLE 1 SEALANT BEHIND FLANGE SUBSTRATE BY OTHERS Z O z=� Q K WOO 0 h- 0 Lj Q = F w BYINSTALLER SEE TABLE 1 O o O m I- 0- h a)a z—�ZzrDrn PERIMETER SEALANT Q 0 fj g Z 0 �+ z BYINSTALLER _ 2 0 INSIDE AND OUT Q t- z Ixa}U)U— aj W LL w U) rn W HORIZONTAL SECTION R Z a O � U) h TYPICAL JAMB ANCHORAGE 0 W f a Lj 3 W U) 1/4" MAX. SHIM SEALANT BEHIND FLANGE BYINSTALLER PERIMETERSEALANTMINEMBEDMENT SEE TABLE ENj BYINSTALLER INSIDE AND OUT ="0 No. 58201 SUBSTRATE BY OTHERS _� Zir u SEE TABLE 1 -- --MIN. EDGE DIST. i STATE OF STA SEE TABLE 1 �O ` rA-'\ VERTICAL SECTION //��NAL1�N\��``` �7_TTYPICAL SILL ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1-1/2" 1-118" HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON 1" 2" CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1" 1" GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-314" 2-1/2" 2XMIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON 1-3/8„ 7/8„ 2XMIN. SOUTHERN PINE (G=0,55) #10 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.06W) MIN, STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEXOR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7/16" 118" ALUM, (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING / DRILLING SCREW FULL THREAD THRU 0.125" 7/16" 8/18/2020 LUCAS A. TURNER, P,E. FL PE # 58201 2428 Old Natchez Trc Tri Camden, TN 38320 PH.941-380-1574 INSTALLATION DETAILS ADE 06/01/12 VG #: REV.: CWS-774 D :ALE: SHEET 1:2 70177