Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Report (Paul Marcussen (LF EST)) - Florida Window & DoorProperty Information Owner:Paul Marcussen (LF EST) Address:5200 Seagrape Dr Fort Pierce, FL 34982 Building Information Wind Zone:165 MPH. Exposure Category:C Minimum Building Dimension:30 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 37 80 7 33.9 -44.3 2 End 74 63 7 32.9 -42.2 3 End 37 38 7 35.6 -47.7 4 End 72 80 7 32.4 -41.3 5 End 53 38 7 34.8 -46.1 6 End 53 38 7 34.8 -46.1 7 End 74 38 7 34.1 -44.6 8 End 37 26 7 35.6 -47.7 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1