Loading...
HomeMy WebLinkAboutAPPROVED Single Hung FL15699.112/17/2020 Florida Building Code Online Professional-gl R BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search dbor 4-- Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL15699-R5 Application Type Revision Code Version 2020 Application Status Approved Comments Public comment; Remove proprietary note and does not comply w/ 2411.1.11.11/18/20 Archived Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Authorized Signature Jay Lathrop jlathrop@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Lucas A. Turner Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 07/21/2028 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL15699 R5 COI EvalREuurt7Z6D.ldf Standard AAMA/W DMA/CSA/ 101/I. S.2/A440 ASTM E1886-13a ASTM E1996-17 PA TAS 201/202/203 Year 2008 2013 2017 1994 Equivalence of Product Standards https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvutH8jlpVzpOUF%2bvTH11AVnYhdBPK8BYvxldwlgbLzjg%3d%3d 1/2 12/17/2020 Certified By Florida Building Code Online Florida Licensed Professional Engineer or Architect FL15699 R5 Equiv 3100 Equivalency_pdf Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Produets Method 1 Option D 08/27/2020 08/30/2020 09/18/2020 12/15/2020 FL # Model, Number or Name Description 15699.1 SH-3100 SH-3100, Aluminum Single Hung, Impact Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL15699 R5 II CWS-726D.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact, see Installation drawings for DP FL15699 R5 AE EvalReport726D,pdf and sizes. Glass complies with ASTM E1300. Created by Independent Third Party: Yes [-1 Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: IT NW"_1 ® _C _ E Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvutH8jIpVzpOUF%2bvTHI1AVnYhdBPK8BYvxldwlgbLzjg%3d%3d 212 URNER ENGINEERING & CONSULTING. INC. 2428 Old Natchez Trace Trail Camden, TN 38320 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 726D August 18, 2020 Product Description: Series 3100 (previously 3700) Aluminum Single Hung Window, LM Impact, max. unit sizes of 53 1/8" x 84" DP70 Oriel, 53 1/8" x 76" DP70 OX Equal Split, and 37" x 63" DP80 OX Equal Split Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 71h Edition (2020) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, PE, at 2428 Old Natchez Trc Trl, Camden, TN 2) Approval drawing CWS-726D, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3795-1, -IA, -2, -2A, -3, and -3A, and NCTL-210-4000-01, -IA, -02, and -2A from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E., and test reports CWS-004-02-02 and -03 and CWS-005-02-01 and -02 from PRI Construction Materials Technologies, Tampa, FL, with testing Performed: TAS 201/202/203 1994, AAMA/WDMA/CSA 101/I.S.2/A440-2008, ASTM E 1886-2002/2004/2005, and ASTM E 1996-2002/2004/2006/2009 4) Supplemental Calcs. to support CWS-726D, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-726D. Limitations of Use: This product: • May be used up to sizes indicated above in Product Description, with glass types, design pressures, and max. glass daylight sizes as shown in CWS-726D • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • I.G. glass with annealed outboard lite may not be used above 30 ft from grade in HVHZ • Requires Kuraray Butacite PVB Interlayer per Miami -Dade NOA 19-0305.02' • Requires 6063-T6 aluminum extrusions per CWS-726D t I have evaluated the material in this NOA and find that it complies with the requirements of the 7th Edition (2020) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. N Lucas Turner -Srll* 2020.08.21 =� No. 58Z0'! p� 08/18/202 1 0 10:17:34 ;��1 * 'w Lucas A. Turner, P.E. Cs -05'00� "� STATE OF �� FL PE #58201 01 R( DRAT' /11111tt1 SINGLE HUNG - IMPACT 53 1/8" UNIT WIDTH 50" GLASS DLO A 6 A 53 1/8" UNIT WIDI FrS DLO B B 501/4" GLASS UNT HEIGHT 38 7/8„ 30 5/8" 1 SASH HEIGHT X /\ 4 I 25 3/4" GLASS DLO SASH HEIGHT 48 1/8" GLASS DLO G F-48 118" GLASS DLO-- 51 5/8" SASH WIDTH 51 5/8" SASH WIDTH - ORIEL EQUAL SPLIT TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS .......... 1 GLAZING DETAIL......................................2 SECTION VIEWS.......................................3 EXTRUSIONS & B.O.M ..............................4 ANCHOR SCHEDULE & NOTES...............5 INSTALLATION DETAILS ..........................6 GLASS DLO 37" UNIT WIDTH 33 718" GLASS DLO O 27 1/2" GLASS DLO 1 63" UNIT HEGHT I I 323/8" X 271/2" SASH GLASS HEIGHT DLO 32" GLASS DLO --I 1+351/2" SASH WIDTH" -I EQUAL SPLIT GENERAL NOTES: g®m q 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WINDOW STSTEMS WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE 1900 SW 44TH AVE. HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 OCALA, FLORIDA 34474 MISSILE LEVEL D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2. GLAZING DETAILS: (SEE SHEET 2) 3. CONFIGURATIONS: "D/X" 3100 ALUM. SINGLE HUNG 4. DESIGN PRESSURES: -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES IMPACT ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER O INFILTRATION TEST PRESSURE, AND GLASS TABLES ASTM E-1300-04e01/09. F - w 0� W o Z W J. ¢ Z w 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE w o Z 0 Z of - - (- OF Fn DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR INSTALLATION DETAIL. WIND F w z � 2 Hi LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR Z O Z x ¢ of w O 0 01-0 ¢ CALCULATIONS. 0 O rn l- Z a P V) a 6. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT Z } O Z Q cn z o U - ~-LL�QOwz REQUIRED. x ¢Ow-O- 7. ALL FRAMES AND SASHES ARE PROCESSED AND SCREWED TOGETHER. SMALL z O a > x JOINT SEALANT USED AT ALL FRAME JOINTS. W Z m w rn 0 w a W 8. SERIES / MODEL DESIGNATION SH-3100. (A.K.A. SH-3700) 0_ wT-0 xa=w� x w a h a �3:w a 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X = OPERABLE SASH, O = FIXED SASH 10. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS. je ZtiNo. 58201 Lucas Turner '9-ffffff* tea' STATE OF 2020.08.21 10:21:51 -05'00' �IV Air CONFIG. MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING ORIEL 53-1/8" x 84" +/- 70 PSF LARGE MISSILE IMPACT EQUAL 53-1/8" x 76" +/- 70 PSF EQUAL 1 37" x 63" +/_ 80 PSF 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH.941-380-1574 GENERAL NOTES AND ELEVATIONS DRAWN BY. DATE: TEF 05/17/12 DWG#: REV.: CWS-726 D TALE' SHEET 1:25 1 OF 6 5/16" OVERALL 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 1/8" ANNEALED 34 PURFECT GLAZE 'H" OR SIKAFLEX 552 3/4" GLASS BITE GLASS TYPE A - SASH 7/8" OVERALL 1/8" ANNEALED 7/16" AIRSPACE 5/16" LAMINATED 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 118" ANNEALED 34 PURFECT GLAZE "H" OR SIKAFLEX 552 3/4" GLASS BITE QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER GLASS TYPE C - SASH 5/16" OVERALL 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 1/8" ANNEALED 34 PURFECT GLAZE "H" OR SIKAFLEX 552 10 1 314" GLASS BITE 3' 1 GLASS TYPE A - FIXED 7/8" OVERALL 118" ANNEALED 7/16" AIRSPACE 5116" LAMINATED 1/8" ANNEALED .090 DUPONT PVB INTERLAYER 1/8" ANNEALED 34 PURFECT GLAZE"H" OR SIKAFLEX 552 ' 314" GLASS BITE GLASS TYPE C - FIXED NEX DURASEAL or, DINAL XL EDGE or, ISPACE 4SG TPS ;PACER —7116" OVERALL —3/16'. ANNEALED —.105 DUPONT PVB INTERLAYER —3116" ANNEALED 34 PURFECT GLAZE"H" OR SIKAFLEX 552 1 3/4" GLASS BITE GLASS TYPE B - FIXED 7/8" OVERALL 3l16" ANNEALED 1/4" AIRSPACE 7116" LAMINATED 3/16" ANNEALED .105 DUPONT PVB INTERLAYER 3/16" ANNEALED 34 PURFECT GLAZE "H" OR SIKAFLEX 552 . _ 3/4' GLASS BITE GLASS TYPE D - FIXED QUANEX DURASEAL or, CARDINAL XL EDGE or, KODISPACE 4SG TPS I.G. SPACER SETTING BLOCKS PER FBC 2411.3.3.1 TYPE DESIGN PRESSURE (PSF) MAX. SIZE SASH GLASS FIXED GLASS EQUAL +/- 80 37" x 63" A or C A or C +/- 70 53" x 76" A or C A or C ORIEL +/- 70 53" x 84" A or C B or D WINDOW SYSTEMS k- 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3100 ALUM. SINGLE HUNG I M PACT Q Z 3: QZ O W 0 ZQZ K_zh Z F-WZO��= ZS�QXowFpOOC x~a0)l-n?o Qzo Z— Z —wZ�U- -o200Z>- <3:0FF=0— U) aLL -j O wC Lu~w wT�rn 2 L F- D- No. 58201 STATE OF ,,Ao110t'. 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 SHEET DESCRIPTION: GLAZING DETAILS DRAWN BY: DATE: TEF 05/17/12 DWG N: REV.: CWS-726 D -§GALE: SHEET 1:1 20F6 INTERIOR WINDOW SYSTEMS 111`�� 4 32 19 31 9 33 31 32 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CW S.CC 4 � 11 -- 3100 ALUM. SINGLE HUNG 1j-"� or37 11 IMPACT --1 ...... ¢ Z ¢ Z Z Lu 0 ¢w��W 33 9 25 Z Z w Q K� 2_ 6 20 10or36or37 30 33 SECTIONS-B 4 8 p O prp Qw1O Urn�ZD-11v a 8 Z O—�—Z�UV7 L{ Q �zLLg�01L0 1p— t INTERIOR ¢ } v — Z rn r~11 0 1X(n0WOw D_ 0-0 - t9 of wH 0 o-=w> 7 7 F=- 4. LJ�d 17 `tttpitltll!/// TU/�/ /l 30 A a Map q * 'k = d No. 58201411 30 —ti 15 01 -TATEOF 040WpN 24 10 8/18/2020 19 LUCAS A. TURNER, P.E. FL PE # 58201 19 2428 Old Natchez Trc Trl Camden,0 PH. 941 3 0 1574 SHEET DESCRIPTION: 35 SECTION C-C SECTION VIEWS ALT. SILL LATCH NOTE: MONOLITHIC LAMI SHOWN. DRAWN BY: DATE: IG AVAILABLE, SEE SHEET 2. TEF 05/17/12 5 30 13 DWG#: REV.: ITEMS NOT SHOWN FOR CLARITY: CWS-726 D SECTION A -A 14, 16, 18, 21, 22, 26, 27 SCALE SHEET 1:1.33 30F6 VIA I 2 3/4" 7 Aluminum Aluminum Aluminum Aluminum 2 1/16" 4 Aluminum Aluminum 1/16" Aluminum - - Aluminum Aluminum FRAME HEAD - S-1931 12 1 S-1956 ISill Latch Aluminum 13 P-3018 Wstp., .300 x .187 Bulb Vinyl Nylon 14 P-3029 Screen Pull Tab Steel 15 P-3033 Screen Spring, SS SS 16 P-3046 Take Out Clip 17 P-3218 Screen Frame Alum 18 P-3228 Screen Spline, .155 Dia., Blk. Nylon 19 P-3305 Wstp.,.270 x.187 Black SoftTouch Center Fin, Black Nylon 20 1 P-3309 lWstp.,.210 x.187 Black Soft Touch Center Fin, Black Nylon 21 P-3321 Screen Frame Corner Key Alum 22 P-3342 Seam Sealer, SM-5504 23 P-5637 Set. Blk., 85 Dur., 1/8" x 3/8" x 2" Lg. 24 P-3443 Wstp, .290 X.187 Black, Bulb Vinyl, Hollow Nylon 25 P-3515 #8 x 0,625 Ph FH Type A SMS Steel 26 P-3581 Screen Cloth, 18 x 16 Fiberglass 27 P-4144 #8 x 1" w/ 1/4" lead Quad PH Type A SMS Steel 28 1 P-4707 ISweep Lock Nylon 30 P-4959 Wstp., .420 x .187 back PolyFin, Gray, SoftTouch Nylon 31 P-5228 Sash Cam 32 Balancer 33 GLASS See Sheet 2 34 Purfect Glaze "H" or Sikaflex 552 35 P-5244 Closed Cell Pad, 1-1/2"xl-1/4"x3/16" 3/ I P-bb23 (Glazing Bead, IG (7/8" OA) PVC LIN 29 E ITEMS NOT USED: NOTE: ALUMINUM PROFILES ARE 6063-T6 UNLES OTHERWISE NOTED. SASH CORNER FRAME CORNER FIXED MTG RAIL CONSTRUCTION CONSTRUCTION CONSTRUCTION 7 2 7 �A SMALL JOINT SEAM SEALANT USED AT ALL FRAME JOINTS 3 FRAME SILL - S-1932 2 5/8" 6 2 3/16" L 1/16" FRAME JAMB - S-1933 13/16" 1 1/4" 12 1/16" SILL LATCH - S-1956 —2112" /( f7/1 9frimfjiyjj 1 WINDOW SYSTEMS 1900 SW 44TH AVE, OCALA, FLORIDA 34474 25/16" 7/8" � ^ WWW.CWS.CC ,A6 L ==9 1/6" 3100 ALUM. REINFORCEMENT-S-1935 SINGLE HUNG SASH MTG RAIL - H-1946 IMPACT ? � QZ0 11I6" �wl f-wZa pZ of=Z U. OI-WZ�:22Z ZX: <ofLu00 O Of- OEja=F- of m�Z I-0Q- III-y-1-�-IL� 9 Q O Z 0 U)Z 0LL 0 2 1/2" IJUI� 1 3/4 >' Q p F- 2 O? Q g�}rpU~ZUJ in6" 1/16" W OOxai0LuOw j z cn a O � v1 I- O WF-0 wOOf(n SASH SIDE RAIL-S-1939 a , M I 0- FIXED MTG RAIL - H-1934 %%N%111111111" A. *( No.58201 *' 3 T— 6 /L.* jYf 2 5/6" t 3/t s" -� STATE OF v16° frrrrr����1111A1111����`�� SASH STOP - S-1954 SASH BTM RAIL - H-1947 3/a 8/18/2020 1/2" 15/16" 9/16" 36 LUCAS A. TURNER, P.E. IJFFL PE # 58201 1/16" 2428 Old Natchez Trc Trl Camden, TN 38320 1/16" PH. 941-380-1574 SCREEN ADAPTOR - S-1936 GLAZING BEAD, 7/16" - S-1949 SHEET DESCRIPTION: „ BOM AND EXTRUSIONS 3/4"' 3/4 3/16" r- 5/8" DRAWN SY, DATE' 37 10 TEF 05/17/12 7/8" 1/16" 1," 1/16" DWG p: REV.: J— j— CWS-726 D PVC GLAZING BEAD, 718" IG - P-6523 GLAZING BEAD, 5/16" - S-1941 scALE : SHEET 1:2 4 OF 6 6" MAX. 6" MAX, (TYP.)— 12 112" MAX. O.C. (TYP.) ---SEE NOTE 2 6" MAX. (TYP.) — � / I 19 1/2" MAX O.C. INSTALLATION (TYP.) O ANCHORS (TYP.) L I I I I I 1 4„ (T 4" (TYP) 4' 4" (TYP.) _ I x I ANCHOR LAYOUT EQUAL SPLIT 37" X 63" 6" MAX. (TYP.)—r---f--- i 14" MAX. O.C. (TYP.) ANCHOR LAYOUT EQUAL SPLIT 53.125" X 76" 6" D 6" MAX. (TYP.; )TE 2 INSTALLATION ANCHORS (TYP.) INSTALLAT ANCHORS 4" (TYP.)- 4" (TYP.)- AX, (TYP.) 14" MAX. O.C. (T 2 SEE NOTE 2 13 112" MAX. O.C. (TY+ .) I I ON TYP.) I I I I I O I I I � � I I I I I X I �P 16"I L � I ANCHOR LAYOUT ORIEL 53.125" X 84" NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION, SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND THE SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 4" FOR MASONRY, 1" FOR WOOD AND METAL. 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMAIWDMA300(EXTERIOR DOORS) gbM WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3100 ALUM. SINGLE HUNG IMPACT Q ? !�: ¢ZO ¢ W0 W ZJOZ CY- �F 0 F W �O LL ' Z p � � _ Z Z S Q X W 0 0 0 01-0U ¢=Fw 0 Z—W—ZF to P—�M00,0 r>- Q§OW-20— Q~Zrri W OLL O�lgOWfA U�.J tY z�a 0-1w - X =~x W�w`n 0- r- M W a No. 58201 STATE OF a !kGR1Gr, 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 5820 11 2428 Old Natchez Trc Trl Camden, TN 38320 PH. 941-380-1574 ANCHOR SCHEDULE AND NOTES TEF 05/17/12 VG #. REV.: CWS-726 D ALE: SHEET 1:20 50F6 TYPICAL HEAD ANCHORAGE INTERIOR �® MIN. EDGE DIST, WINDOW SYSCE?15 SEE TABLE 1 1900 SW 44TH AVE. MIN. EMBEDMENT OCALA, FLORIDA 34474 SUBSTRATE BY OTHERS SEE TABLE 1 W WW.CWS.CC SEE TABLE 1 LSE 1/4" MAX. SHIM PERIMETER SEALANT DMENT 31 QO' ALUM. BY INSTALLER E 1 MIN. EDGE DIST. INSIDE AND OUT SEE TAB LE1 SINGLE HUNG SEALANT BEHIND FLANGE INSTALLATION ANCHOR-- IMPACT BY INSTALLER SEE TABLE 1 1l4" MAX. SHIM Q 3: <Zp W ¢W� JO Z rz LL Z w z F W Z O- 2 INTERIOR SEALANT BEHIND FLANGE SUBSTRATE BY OTHERS � BY INSTALLER SEE TABLE 1 J Z Z F=- O Q 1= 0 0 U INSTALLATION ANCHOR U U m� Z M l- p M SEE TABLE 1 PERIMETER SEALANT— BY INSTALLER p Z— to Z N_ U) (7 Z Q 0 u. U — INSIDE AND OUT F- —' g Z p I Z B HORIZONTAL SECTION H W K F ?� O 6 TYPICAL JAMB ANCHORAGE w Z m W U) O0 w op) a En p wF=-0w a.X: 1/4" MAX. SHIM d F d O d SEALANT BEHIND FLANGE BYINSTALLER PERIMETER SEALANT BY INSTALLER MIN. EMBEDMENT TUJk,F //�� INSIDE AND OUT SEE TABLE 1 `��� JCpgA N�. SUBSTRATE BY OTHERS *f SEE TABLE 1 _.tip Na. 58201* MIN. EDGE DIST. ��� STATE SEE TABLE 1 OF (�VERTICAL SECTION _ 6 TYPICAL SILL ANCHORAGE////��.-�:A�•-�������` TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1-1/2" 1-1/8" HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" ITW TAPCON 1" 4" CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1" 1" GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 2-1/4" 2-1/2" 2XMIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON 1-3/8" 7/8" 2XMIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEX OR ITV TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7/16 1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING / DRILLING SCREW FULL THREAD THRU 0,125" 7/16" 8/18/2020 LUCAS A. TURNER, P.E. FL PE # 58201 2428 Old Natchez Trc TO Camden, TN 38320 PH.941-380-1574 AEET DESCRIPTION: INSTALLATION DETAILS RAWN BY', DATE: TEF 05/17/12 JVG #: REV.: CWS-726 D 'ALE' SHEET 1:2 6OF6