APPROVED MANJ(1)
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Load Short Form Jun 21, 2021Date:Entire House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com Project Information Newton Residence, Groza Builders, IncFor: 5804 Raintree Trail, Fort Pierce, FL 34982 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA38MV-036-230*++TDR AHRI ref 204289059 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.3 Sensible cooling Btuh23940 Heating output Btuh24800 Latent cooling Btuh10260 Temperature rise °F20 Total cooling Btuh34200 Actual air flow cfm1140 Actual air flow cfm1140 Air flow factor cfm/Btuh0.046 Air flow factor cfm/Btuh0.051 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.77 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) AC 16 0 0 0 0 Bath 2 77 1678 648 78 33 Bed 2 180 2766 1924 128 98 Bed 3 165 1353 1491 63 76 Dining Room 138 1512 2316 70 118 Dining/Foyer 141 3103 1730 144 88 Gathering Room 263 965 2619 45 134 Hallway 137 0 0 0 0 Kid Kave 161 2341 1995 109 102 Kitchen 167 866 3624 40 185 Laundry 68 703 267 33 14 Linen 29 0 0 0 0 M Bath 160 1552 840 72 43 Master Bedroom 306 4996 3277 232 167 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N WIC 129 2694 1554 125 79 Wrt Clst 18 23 36 1 2 Entire House 2151 24553 22320 1140 1140 Other equip loads 1642 872 Equip. @ 0.95 RSM 22125 Latent cooling 6953 TOTALS 2151 26195 29078 1140 1140 2021-Jun-22 14:58:17 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Building Analysis Jun 21, 2021Date:Entire House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com Project Information Newton Residence, Groza Builders, IncFor: 5804 Raintree Trail, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 17.746252.6Walls 5.815079.3Glazing 0.51433.7Doors 8.121241.0Ceilings 25.065393.03.0Floors 12.632992.0Infiltration 24.16316Ducts 00Piping 00Humidification 6.31642Ventilation0Adjustments 100.026195Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 11.626951.5Walls 14.4333020.5Glazing 0.61453.7Doors 13.531351.5Ceilings 000Floors 3.88760.5Infiltration 30.77119Ducts 3.8872Ventilation 21.65020Internal gains 00Blower 0Adjustments 100.023192Total Latent Cooling Load = 6953 Btuh Overall U-value = 0.082 Btuh/ft²-°F Data entries checked. 2021-Jun-22 14:58:17 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Component Constructions Jun 21, 2021Date:Entire House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com Project Information Newton Residence, Groza Builders, IncFor: 5804 Raintree Trail, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Block R-9 Wall: Blk Wall, Stuc Ext, 8" Thk, R-9 Foam Fill, 1/2" Gyp Bd 12322.589.00.089478ne 7881.65 3431.655362.589.00.089208se 5511.658622.589.00.089335sw 5921.659252.589.00.089359nw 22731.6535542.589.00.0891380all Frm wall, Stucco Ext, R-30 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x6" Wd Frm, 16" OC Stud 51.0381.6130.00.0555ne 131.03211.6130.00.05513se 51.0381.6130.00.0555sw 321.03501.6130.00.05531nw 551.03871.6130.00.05554all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 3661.099842.9411.00.101335 Windows Windows: Windows; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (3 ft window ht, 1 ft sep.); 6.8 ft head ht 8118.0429.2800.3205ne Windows: Windows; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 18718.0979.2800.32010ne 53817.22909.2800.32031sw 56118.02909.2800.32031nw 128617.76769.2800.32073all Windows: Windows; NFRC rated (SHGC=0.19); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht 70415.64058.9900.31045se Windows: Windows; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 8.5 ft overhang (6.7 ft window ht, 1 ft sep.); 6.8 ft head ht 81320.23859.5700.33040nw Doors Fbrgls Door 673.73663.697.00.12718ne 783.73773.697.00.12721se 1453.731433.697.00.12739all 2021-Jun-22 14:58:17 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N Ceilings Attic, Shngl Roof, R-30 Ceil Ins, 5/8" Gyp Bd 0.0342151 31351.4621240.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00653928.700.989228 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Project Summary Jun 21, 2021Date:Entire House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com Project Information Newton Residence, Groza Builders, IncFor:5804 Raintree Trail, Fort Pierce, FL 34982 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18238 Structure Btuh15201 Ducts Btuh6316 Ducts Btuh7119Central vent (52 cfm) 1642 Btuh Central vent (52 cfm) Btuh872 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh26195 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh22125 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2800 Ducts Btuh2163Central vent (52 cfm) Btuh1991 CoolingHeating Outside air21512151Area (ft²) Equipment latent load Btuh6953 1940619406Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh29078 Equiv. AVF (cfm) 52104 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond ML14XC1S036-230C**AHRI ref Coil CBA38MV-036-230*++TDR AHRI ref 204289059Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.3 Sensible cooling Btuh23940Heating output Btuh24800 Latent cooling Btuh10260 Temperature rise °F20 Total cooling Btuh34200Actual air flow cfm1140 Actual air flow cfm1140 Air flow factor cfm/Btuh0.046 Air flow factor cfm/Btuh0.051Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Entire House AC 2 Exposed wall 228.0 ft 0 ft 3 Room height 9.0 ft 8.0 heat/coolft 4 Room dimensions ft4.5x3.5 5 Room area 2151.3 ft²15.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 511 478 1232 788 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 5 0 42 81 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 10 0 97 187 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 18 18 66 67 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 5 5 8 5 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 274 208 536 343 0 0 0 0 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 45 11 405 704 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 21 21 77 78 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 13 13 21 13 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 366 335 862 551 0 0 0 0 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 31 8 290 538 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 5 5 8 5 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 430 359 925 592 0 0 0 0 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 31 0 290 561 0 0 0 0 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 40 0 385 813 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 31 31 50 32 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 335 335 984 366 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 2151 2151 2124 3135 16 16 16 23 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 2151 228 6539 0 16 0 0 0 6 c) AED excursion 445 -1 Envelope loss/gain 14939 9305 16 22 12 a) Infiltration 3299 876 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 4100 0 Subtotal (lines 6 to 13)18238 15201 16 22 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -16 -22 14 Subtotal 18238 15201 0 0 15 Duct loads 35%47%6316 7119 35%47%0 0 Total room load 24553 22320 0 0 Air required (cfm)Air required (cfm)1140 1140 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Bath 2 Bed 2 2 Exposed wall 17.5 ft 27.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft8.5x9.0 ft12.0x15.0 5 Room area 76.5 ft²180.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 68 50 129 83 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 18 18 66 67 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 96 96 247 158 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 72 72 185 119 120 104 269 172 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 0 0 0 0 16 0 145 281 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 77 77 76 111 180 180 178 262 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 77 18 502 0 180 27 774 0 6 c) AED excursion -21 64 Envelope loss/gain 958 358 1613 937 12 a) Infiltration 282 75 436 116 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 250 Subtotal (lines 6 to 13)1240 433 2049 1302 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 6 8 6 8 14 Subtotal 1246 441 2055 1311 15 Duct loads 35%47%432 207 35%47%712 614 Total room load 1678 648 2766 1924 Air required (cfm)Air required (cfm)78 33 128 98 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 3...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Bed 3 Dining Room 2 Exposed wall 11.0 ft 9.5 ft 3 Room height 8.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft11.0x15.0 ft14.5x9.5 5 Room area 165.0 ft²137.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 88 72 187 119 0 0 0 0 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 16 2 145 269 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 0 0 0 0 76 36 92 59 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 40 0 385 813 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 0 0 0 0 19 19 31 20 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 165 165 163 240 138 138 136 201 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 165 11 315 0 138 10 272 0 6 c) AED excursion 64 412 Envelope loss/gain 810 693 916 1505 12 a) Infiltration 178 47 192 51 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 0 Subtotal (lines 6 to 13)987 990 1108 1556 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 18 25 16 22 14 Subtotal 1005 1015 1123 1578 15 Duct loads 35%47%348 475 35%47%389 739 Total room load 1353 1491 1512 2316 Air required (cfm)Air required (cfm)63 76 70 118 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 4...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Dining/Foyer Gathering Room 2 Exposed wall 29.0 ft 7.0 ft 3 Room height 10.0 heat/coolft 11.0 heat/coolft 4 Room dimensions ft141.3x1.0 ft15.0x17.5 5 Room area 141.3 ft²262.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 20 20 52 33 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 5 5 8 5 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 162 118 305 195 0 0 0 0 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 23 3 203 352 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 21 21 77 78 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 13 13 21 13 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 90 90 264 98 77 77 226 84 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 141 141 139 206 263 263 259 383 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 141 29 832 0 263 7 201 0 6 c) AED excursion 90 -86 Envelope loss/gain 1901 1071 686 381 12 a) Infiltration 403 107 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 0 900 Subtotal (lines 6 to 13)2305 1178 686 1741 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 31 43 14 Subtotal 2305 1178 717 1784 15 Duct loads 35%47%798 552 35%47%248 835 Total room load 3103 1730 965 2619 Air required (cfm)Air required (cfm)144 88 45 134 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 5...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Hallway Kid Kave 2 Exposed wall 0 ft 25.0 ft 3 Room height 10.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft136.5x1.0 ft160.5x1.0 5 Room area 136.5 ft²160.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 8 8 21 13 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 92 76 197 126 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 0 0 0 0 16 2 145 269 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 100 100 294 109 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 137 137 135 199 161 161 158 234 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 137 0 0 0 161 25 717 0 6 c) AED excursion -9 46 Envelope loss/gain 135 190 1531 797 12 a) Infiltration 0 0 202 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)135 190 1733 1351 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -135 -190 6 8 14 Subtotal 0 0 1739 1359 15 Duct loads 35%47%0 0 35%47%602 636 Total room load 0 0 2341 1995 Air required (cfm)Air required (cfm)0 0 109 102 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 6...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Kitchen Laundry 2 Exposed wall 6.0 ft 8.5 ft 3 Room height 10.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft14.5x11.5 ft8.0x8.5 5 Room area 166.8 ft²68.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 48 48 124 79 0 0 0 0 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 12 12 19 12 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 68 68 200 74 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 167 167 165 243 68 68 67 99 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 167 6 172 0 68 9 244 0 6 c) AED excursion -119 -8 Envelope loss/gain 480 216 511 165 12 a) Infiltration 121 32 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 1700 0 Subtotal (lines 6 to 13)601 2408 511 165 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 43 60 12 16 14 Subtotal 643 2468 522 182 15 Duct loads 35%47%223 1156 35%47%181 85 Total room load 866 3624 703 267 Air required (cfm)Air required (cfm)40 185 33 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 7...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Linen M Bath 2 Exposed wall 4.5 ft 11.5 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft4.5x6.5 ft159.5x1.0 5 Room area 29.3 ft²159.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 36 36 93 59 92 88 225 144 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 5 0 42 81 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 29 29 29 43 160 160 157 232 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 29 5 129 0 160 12 330 0 6 c) AED excursion -6 -21 Envelope loss/gain 251 96 755 437 12 a) Infiltration 73 19 186 49 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)323 116 940 486 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -323 -116 213 86 14 Subtotal 0 0 1153 572 15 Duct loads 35%47%0 0 35%47%399 268 Total room load 0 0 1552 840 Air required (cfm)Air required (cfm)0 0 72 43 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 8...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Master Bedroom WIC 2 Exposed wall 45.0 ft 26.5 ft 3 Room height 8.8 heat/coolft 8.0 heat/coolft 4 Room dimensions ft23.5x13.0 ft129.0x1.0 5 Room area 305.5 ft²129.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 207 196 506 324 88 88 227 145 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 0 0 0 0 0 0 0 0 .GG WindowsWindows 0.3200.320 nene 9.289.28 17.9917.99 10 0 97 187 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 11 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nene 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 104 81 210 134 GG WindowsWindows 0.3100.310 sese 8.998.99 15.6315.63 0 0 0 0 23 3 203 352 DD Fbrgls DoorFbrgls Door 0.1270.127 sese 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 sese 1.611.61 1.031.03 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 75 75 193 123 15 15 39 25 GG WindowsWindows 0.3200.320 swsw 9.289.28 17.2417.24 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 swsw 1.611.61 1.031.03 0 0 0 0 5 5 8 5 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 114 99 255 163 0 0 0 0 GG WindowsWindows 0.3200.320 nwnw 9.289.28 17.9917.99 16 0 145 281 0 0 0 0 GG WindowsWindows 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 WW Frm wall, Stucco Ext 0.055Frm wall, Stucco Ext 0.055 nwnw 1.611.61 1.031.03 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 306 306 302 445 129 129 127 188 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 306 45 1291 0 129 27 760 0 6 c) AED excursion -53 95 Envelope loss/gain 2787 1470 1573 945 12 a) Infiltration 799 212 428 114 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)3586 2182 2001 1058 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 125 50 0 0 14 Subtotal 3711 2232 2001 1058 15 Duct loads 35%47%1285 1045 35%47%693 496 Total room load 4996 3277 2694 1554 Air required (cfm)Air required (cfm)232 167 125 79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-22 14:58:17Right-Suite® Universal 2021 21.0.07 RSU27054 Page 9...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Right-J® Worksheet Jun 21, 2021Date:Entire House Vicki Lynne NisaBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com 1 Room name Wrt Clst 2 Exposed wall 0 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft5.0x3.5 5 Room area 17.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Block R-9 Wall 0.089 ne 2.58 1.65 0 0 0 0 .G Windows 0.320 ne 9.28 17.99 0 0 0 0 .G Windows 0.320 ne 9.28 17.99 0 0 0 0 .D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 11 W Frm wall, Stucco Ext 0.055 ne 1.61 1.03 0 0 0 0 W Block R-9 Wall 0.089 se 2.58 1.65 0 0 0 0 G Windows 0.310 se 8.99 15.63 0 0 0 0 D Fbrgls Door 0.127 se 3.69 3.73 0 0 0 0 W Frm wall, Stucco Ext 0.055 se 1.61 1.03 0 0 0 0 W Block R-9 Wall 0.089 sw 2.58 1.65 0 0 0 0 G Windows 0.320 sw 9.28 17.24 0 0 0 0 W Frm wall, Stucco Ext 0.055 sw 1.61 1.03 0 0 0 0 W Block R-9 Wall 0.089 nw 2.58 1.65 0 0 0 0 G Windows 0.320 nw 9.28 17.99 0 0 0 0 G Windows 0.330 nw 9.57 20.23 0 0 0 0 W Frm wall, Stucco Ext 0.055 nw 1.61 1.03 0 0 0 0 P Frm Wall, 1/2" Gyp B 0.101 -2.94 1.09 0 0 0 0 C Attic, Shngl Roof, R 0.034 -0.99 1.46 18 18 17 26 F On Grade Depth, Tile 0.989 -28.68 0.00 18 0 0 0 6 c) AED excursion -1 Envelope loss/gain 17 24 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)17 24 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 17 24 15 Duct loads 35%47%6 11 Total room load 23 36 Air required (cfm)1 2 2021-Jun-22 14:58:18 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Duct System Summary Jun 21, 2021Date:Entire House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com Project Information Newton Residence, Groza Builders, IncFor: 5804 Raintree Trail, Fort Pierce, FL 34982 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.350 / 0.350 in H2O in H2O0.350 / 0.350 Lowest friction rate in/100ft0.288in/100ft0.288 Actual air flow cfm1140cfm1140 Total effective length (TEL) ft243 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st2200.039.2VlFx0x06.00.29340931678hBath 2 st2200.042.9VlFx0x07.00.2881181542766hBed 2 st2200.032.8VlFx0x06.00.30191751491cBed 3 st1200.022.8VlFx0x07.00.314142842316cDining Room st3205.020.5VlFx0x07.00.3101061733103hDining/Foyer st3205.021.1VlFx0x07.00.310161542619cGathering Room st2200.038.8VlFx0x06.00.2931221302341hKid Kave st2200.032.5VlFx0x06.00.301111241812cKitchen st2200.035.1VlFx0x06.00.298111241812cKitchen-A st2200.037.6VlFx0x04.00.2951639703hLaundry st3205.020.9VlFx0x06.00.31051861552hM Bath st1200.021.5VlFx0x06.00.3161001392498hMaster Bedroom st1200.021.0VlFx0x06.00.3171001392498hMaster Bedroom-A st3205.023.7VlFx0x07.00.306951502694hWIC st3205.018.5VlFx0x04.00.3132136cWrt Clst Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 541 610 0.288 776 12.0 0x0 VinlFlx st1 Peak AVF 363 343 0.314 821 9.0 0x0 VinlFlx st3 Peak AVF 465 415 0.306 852 10.0 0x0 VinlFlx 2021-Jun-22 14:58:18 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 2 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 4280 296 0 0 0 0 x0 0 VlFx rb1 0x 5800 740 0 0 0 0 x0 0 VlFx rb3 0x 1540 118 0 0 0 0 x0 0 VlFx rb2 0x 750 91 0 0 0 0 x0 0 VlFx rb4 0x 1300 122 0 0 0 0 x0 0 VlFx 2021-Jun-22 14:58:18 Right-Suite® Universal 2021 21.0.07 RSU27054 Page 1 ...ments\Wrightsoft HVAC\5804 Raintree Trl GBI.rup Calc = MJ8 Front Door faces: N 1538Job:Manual S Compliance Report Jun 21, 2021Date:Entire House Vicki Lynne NisaBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Web: www.aircalcs.com Project Information Newton Residence, Groza Builders, IncFor: 5804 Raintree Trail, Fort Pierce, FL 34982 Cooling Equipment Design Conditions °F76.9Entering coil DB:Btuh23192Sensible gain:°F90.4Outdoor design DB: °F64.0Entering coil WB:Btuh6953Latent gain:°F77.4Outdoor design WB: Btuh30145Total gain:°F75.0Indoor design DB: cfm1140Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: ML14XC1S036-230C**+CBA38MV-036-230*++TDRModel:LennoxManufacturer: cfm1140Actual airflow: % of load103Btuh23940Sensible capacity: % of load148Btuh10260Latent capacity: %70SHR:% of load113Btuh34200Total capacity: Heating Equipment Design Conditions °F68.1Entering coil DB:Btuh26195Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1140Actual airflow: °F50Temp. rise:% of load95kW7.3Output capacity: Meets all requirements of ACCA Manual S.