Loading...
HomeMy WebLinkAboutAPPROVED TRUSSCUTS(1)Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone: (800)755-6001 www.alpineitw.com Site Information:Page 1: Customer: Central Florida Truss, Inc.Job Number: 21-0598 Job Description: /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Address: 5804 RAINTREE TRAIL, FORT PIERCE, FL Job Engineering Criteria: Design Code: FBC 7th Ed. 2020 Res IntelliVIEW Version: 20.02.01A JRef #: 1X6V7610023 Wind Standard: ASCE 7-16 Wind Speed (mph): 170 Design Loading (psf): 37.00 Building Type: Closed This package contains general notes pages, 65 truss drawing(s) and 6 detail(s). Item Drawing Number Truss Item Drawing Number Truss 1 187.21.1739.44487 T1 2 187.21.1739.49347 T2 3 187.21.1739.51537 T3 4 187.21.1739.53390 T4 5 187.21.1739.55040 T5 6 187.21.1739.56493 T6 7 187.21.1739.58290 T7 8 187.21.1740.03597 T8 9 187.21.1740.04813 T9 10 187.21.1740.06043 T10 11 187.21.1740.07250 T11 12 187.21.1740.08353 T12 13 187.21.1740.09520 T13 14 187.21.1740.10777 T14 15 187.21.1740.11963 T15 16 187.21.1740.13280 T16 17 187.21.1740.14560 T17 18 187.21.1740.15870 T18 19 187.21.1740.17283 T19 20 187.21.1740.19917 T20 21 187.21.1742.08850 T21 22 187.21.1742.11980 T22 23 187.21.1742.24693 T23 24 187.21.1742.49880 T24 25 187.21.1743.03987 T25 26 187.21.1743.10553 T26 27 187.21.1743.14520 T27 28 187.21.1743.18587 T28 29 187.21.1743.24070 T29 30 187.21.1743.26720 T30 31 187.21.1743.29283 T31 32 187.21.1743.31477 T32 33 187.21.1743.33443 T33 34 187.21.1743.35530 T34 35 187.21.1743.37430 T35 36 187.21.1743.38600 T36 37 187.21.1743.40220 T37 38 187.21.1743.41590 T38 39 187.21.1743.42980 T39 40 187.21.1743.44243 T40 41 187.21.1743.45510 T41 42 187.21.1743.47550 V1 43 187.21.1743.48710 V2 44 187.21.1743.49870 J1 45 187.21.1743.51023 J2 46 187.21.1743.52290 J3 47 187.21.1743.53457 J4 48 187.21.1743.54620 J5 49 187.21.1743.56000 K1 50 187.21.1744.04530 K2 51 187.21.1744.07147 K3 52 187.21.1744.08677 K4 Florida Certificate of Product Approval #FL1999 Printed 7/7/2021 9:43:03 AM 07/07/2021 COA #0 278 Alpine, an ITW Company 6750 Forum Drive, Suite 305 Orlando, FL 32821 Phone: (800)755-6001 www.alpineitw.com Site Information:Page 2: Customer: Central Florida Truss, Inc.Job Number: 21-0598 Job Description: /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Address: 5804 RAINTREE TRAIL, FORT PIERCE, FL Item Drawing Number Truss Item Drawing Number Truss 53 187.21.1744.10227 C1 54 187.21.1744.11580 C1A 55 187.21.1744.12900 C2 56 187.21.1744.14010 C2AC 57 187.21.1744.15207 C2T 58 187.21.1744.16323 C3 59 187.21.1744.17383 C3AC 60 187.21.1744.18363 C3T 61 187.21.1744.19337 C4 62 187.21.1744.20540 C5 63 187.21.1744.21493 C5T 64 187.21.1744.22493 C6 65 187.21.1744.25120 C6T 66 BRCLBSUB0119 67 DEFLCAMB1014 68 GBLLETIN0118 69 S18015ENC160118 70 VAL180160118 71 VALTN160118 Florida Certificate of Product Approval #FL1999 Printed 7/7/2021 9:43:03 AM 07/07/2021 COA #0 278 General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer’s seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.org. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re-dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non-Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non-gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non-hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.org. 3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO 63045; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.com. Page 3 of 3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x6 SP #2; Webs: 2x4 SP #2; W1,W9 2x6 SP #2; Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 2 Rows @ 4.50" o.c. (Each Row) Webs : 1 Row @ 4" o.c. Repeat nailing as each layer is applied. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 28 plf at 0.00 to 28 plf at 17.82 BC: From 10 plf at 0.00 to 10 plf at 17.82 BC: 1584 lb Conc. Load at 1.92 BC: 1572 lb Conc. Load at 3.92, 5.92 BC: 1565 lb Conc. Load at 7.92 BC: 1567 lb Conc. Load at 9.92 BC: 1448 lb Conc. Load at 11.92 BC: 1441 lb Conc. Load at 13.92 BC: 949 lb Conc. Load at 15.92 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL J 6488 /-/-/-/4231 /- F 5881 /-/-/-/3596 /- Wind reactions based on MWFRS J Brg Width = 5.5 Min Req =2.6 F Brg Width = 3.5 Min Req =2.3 Bearings J & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 593 -907 B - C 784 -1209 Chords Tens.Comp. C - D 855 -1312 D - E 1163 -1853 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 831 -541 Chords Tens.Comp. H - G 1675 -1051 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 1297 -1982 A - I 1819 -1185 B - I 595 -917 B - H 1298 -832 H - C 459 -284 Webs Tens.Comp. H - D 381 -665 D - G 618 -327 G - E 1934 -1212 E - F 1080 -1709 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.23 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.048 G 999 360 VERT(CL):0.077 G 999 240 HORZ(LL):-0.008 F - - HORZ(TL):0.013 F - - Creep Factor: 2.0 Max TC CSI:0.224 Max BC CSI:0.922 Max Web CSI:0.437 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T1 Ply: 3 Qty:1 SEQN:178515 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T61 DrwNo:187.21.1739.44487 SSB /WHK 07/06/2021 3 Complete Trusses Required W1 W9 17'8"14 1" 3'5"10 3'5"10 6'1"6 2'7"12 11'9"14 5'8"8 17'9"14 6' 3'5"10 3'5"10 5'11"10 2'6" 12'1"6 6'1"12 17'9"14 5'8"87'1"123'8"88'7"110'1" A B C D E FGHIJ 5 12 6X6 3X10 5X8 5X5 5X8 4X4 3X4 7X6 4X5 3X10 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x6 SP #2; Webs: 2x4 SP #2; W1,W9 2x6 SP #2; Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 2 Rows @ 4.50" o.c. (Each Row) Webs : 1 Row @ 4" o.c. Repeat nailing as each layer is applied. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 28 plf at 0.00 to 28 plf at 17.82 BC: From 10 plf at 0.00 to 10 plf at 17.82 BC: 1584 lb Conc. Load at 1.92 BC: 1572 lb Conc. Load at 3.92, 5.92 BC: 1565 lb Conc. Load at 7.92 BC: 1567 lb Conc. Load at 9.92 BC: 1448 lb Conc. Load at 11.92 BC: 1441 lb Conc. Load at 13.92 BC: 949 lb Conc. Load at 15.92 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL J 6488 /-/-/-/4231 /- F 5881 /-/-/-/3596 /- Wind reactions based on MWFRS J Brg Width = 5.5 Min Req =2.6 F Brg Width = 3.5 Min Req =2.3 Bearings J & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 593 -907 B - C 784 -1209 Chords Tens.Comp. C - D 855 -1312 D - E 1163 -1853 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 831 -541 Chords Tens.Comp. H - G 1675 -1051 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - J 1297 -1982 A - I 1819 -1185 B - I 595 -917 B - H 1298 -832 H - C 459 -284 Webs Tens.Comp. H - D 381 -665 D - G 618 -327 G - E 1934 -1212 E - F 1080 -1709 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 16.23 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.048 G 999 360 VERT(CL):0.077 G 999 240 HORZ(LL):-0.008 F - - HORZ(TL):0.013 F - - Creep Factor: 2.0 Max TC CSI:0.224 Max BC CSI:0.922 Max Web CSI:0.437 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T1 Ply: 3 Qty:1 SEQN:178515 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T61 DrwNo:187.21.1739.44487 SSB /WHK 07/06/2021 3 Complete Trusses Required W1 W9 17'8"14 1" 3'5"10 3'5"10 6'1"6 2'7"12 11'9"14 5'8"8 17'9"14 6' 3'5"10 3'5"10 5'11"10 2'6" 12'1"6 6'1"12 17'9"14 5'8"87'1"123'8"88'7"110'1" A B C D E FGHIJ 5 12 6X6 3X10 5X8 5X5 5X8 4X4 3X4 7X6 4X5 3X10 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T2 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; B1,B5 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; W11,W12 2x4 SP 2250f-1.9E; Stack Chord: T1 2x4 SP 2250f-1.9E; Lt Bearing Leg: 2x4 SP #2; Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Plating Notes All plates are 3X4 except as noted. (**) 3 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Bottom chord section directly below beam pocket bearing(s) shall be cut out prior to installing truss. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AF 1840 /-/-/-/1146 /- AE 4824 /-/-/-/2981 /- AG 2428 /-/-/-/1470 /- Wind reactions based on MWFRS AF Brg Width = 7.6 Min Req =1.5 AE Brg Width = 3.5 Min Req =1.5 AG Brg Width = 7.6 Min Req =1.5 Bearings AF, AE, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 2408 -1465 AC- D 1477 -2332 H - J 427 -260 C -AC 1397 -854 D - E 1545 -2483 Chords Tens.Comp. E - F 1126 -1834 J - K 922 -1594 K - L 1573 -2642 L - M 1749 -2925 M - N 1529 -2533 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. C -AC 1766 -1076 AC-AA 2139 -1322 AA- Z 2153 -1323 Z - Y 2482 -1557 Y - V 1785 -1108 Chords Tens.Comp. T - S 1511 -885 S - R 2608 -1564 R - Q 2938 -1770 Q - P 2304 -1371 P - N 2292 -1374 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - Y 474 -722 Y - F 395 -147 F - V 1119 -1788 V - U 327 -513 V - H 932 -588 H -AE 875 -1207 I -AE 1153 -630 Webs Tens.Comp. AE- I 901 -1390 AE- T 1153 -630 T - J 1311 -2179 J - S 816 -360 S - K 745 -1188 Q - M 709 -432 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.10 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.194 L 999 360 VERT(CL):0.352 L 930 240 HORZ(LL):-0.100 X - - HORZ(TL):0.175 X - - Creep Factor: 2.0 Max TC CSI:0.746 Max BC CSI:0.961 Max Web CSI:0.650 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T2 Ply: 2 Qty:1 SEQN:178411 HIPS FROM: Page 1 of 2 Cust: R 761 JRef:1X6V7610023 T47 DrwNo:187.21.1739.49347 SSB /WHK 07/06/2021 2 Complete Trusses Required T2 B1 B5 W11 W12 23'7"4 27'4"12 2"10 2"10 6'3"12 6'1"2 11'8"7 5'4"11 16'9"9 5'1"3 21'9" 4'11"7 23'6"4 1'9"4 29'0"4 5'6" 34'1"12 5'1"8 39'3"4 5'1"8 44'8"4 5'5" 51' 6'3"12 2'8"6 2'8"6 6'5"8 3'9"2 11'4"15 4'11"7 16'6"1 5'1"3 21'7"4 5'1"3 23'0"4 1'5" 24'2"4 1'2" 29'3"12 5'1"8 34'5"4 5'1"8 39'6"12 5'1"8 44'6"8 4'11"12 51' 6'5"81'1' 3'4" (NNL) 6"3 2'9"15 8"3'1"123'4"68'1" 9'0"4ABC D E F G H I J K L M N O PQRSTUVWXYZAAABACADAEAF AG 5 12 3X5(C3)3X4(C3) 3X4(**) 4X12(**) 3X4(**)1.5X4 3X33X3 5X8 1.5X4 5X6 5X6 1.5X4 6X81.5X4 4X16 3X104X5 5X8 5X6 1.5X4 5X8 4X5(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T2 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; B1,B5 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; W11,W12 2x4 SP 2250f-1.9E; Stack Chord: T1 2x4 SP 2250f-1.9E; Lt Bearing Leg: 2x4 SP #2; Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Plating Notes All plates are 3X4 except as noted. (**) 3 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Bottom chord section directly below beam pocket bearing(s) shall be cut out prior to installing truss. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AF 1840 /-/-/-/1146 /- AE 4824 /-/-/-/2981 /- AG 2428 /-/-/-/1470 /- Wind reactions based on MWFRS AF Brg Width = 7.6 Min Req =1.5 AE Brg Width = 3.5 Min Req =1.5 AG Brg Width = 7.6 Min Req =1.5 Bearings AF, AE, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 2408 -1465 AC- D 1477 -2332 H - J 427 -260 C -AC 1397 -854 D - E 1545 -2483 Chords Tens.Comp. E - F 1126 -1834 J - K 922 -1594 K - L 1573 -2642 L - M 1749 -2925 M - N 1529 -2533 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. C -AC 1766 -1076 AC-AA 2139 -1322 AA- Z 2153 -1323 Z - Y 2482 -1557 Y - V 1785 -1108 Chords Tens.Comp. T - S 1511 -885 S - R 2608 -1564 R - Q 2938 -1770 Q - P 2304 -1371 P - N 2292 -1374 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - Y 474 -722 Y - F 395 -147 F - V 1119 -1788 V - U 327 -513 V - H 932 -588 H -AE 875 -1207 I -AE 1153 -630 Webs Tens.Comp. AE- I 901 -1390 AE- T 1153 -630 T - J 1311 -2179 J - S 816 -360 S - K 745 -1188 Q - M 709 -432 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.10 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.194 L 999 360 VERT(CL):0.352 L 930 240 HORZ(LL):-0.100 X - - HORZ(TL):0.175 X - - Creep Factor: 2.0 Max TC CSI:0.746 Max BC CSI:0.961 Max Web CSI:0.650 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T2 Ply: 2 Qty:1 SEQN:178411 HIPS FROM: Page 1 of 2 Cust: R 761 JRef:1X6V7610023 T47 DrwNo:187.21.1739.49347 SSB /WHK 07/06/2021 2 Complete Trusses Required T2 B1 B5 W11 W12 23'7"4 27'4"12 2"10 2"10 6'3"12 6'1"2 11'8"7 5'4"11 16'9"9 5'1"3 21'9" 4'11"7 23'6"4 1'9"4 29'0"4 5'6" 34'1"12 5'1"8 39'3"4 5'1"8 44'8"4 5'5" 51' 6'3"12 2'8"6 2'8"6 6'5"8 3'9"2 11'4"15 4'11"7 16'6"1 5'1"3 21'7"4 5'1"3 23'0"4 1'5" 24'2"4 1'2" 29'3"12 5'1"8 34'5"4 5'1"8 39'6"12 5'1"8 44'6"8 4'11"12 51' 6'5"81'1' 3'4" (NNL) 6"3 2'9"15 8"3'1"123'4"68'1" 9'0"4ABC D E F G H I J K L M N O PQRSTUVWXYZAAABACADAEAF AG 5 12 3X5(C3)3X4(C3) 3X4(**) 4X12(**) 3X4(**)1.5X4 3X33X3 5X8 1.5X4 5X6 5X6 1.5X4 6X81.5X4 4X16 3X104X5 5X8 5X6 1.5X4 5X8 4X5(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 6.31 TC: From 28 plf at 6.31 to 28 plf at 44.69 TC: From 55 plf at 44.69 to 55 plf at 52.00 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 6.34 BC: From 10 plf at 6.34 to 10 plf at 44.52 BC: From 20 plf at 44.52 to 20 plf at 51.00 BC: From 4 plf at 51.00 to 4 plf at 52.00 TC: 300 lb Conc. Load at 6.34 TC: 172 lb Conc. Load at 8.37,10.37,12.37,14.37 16.37,18.37,20.37 TC: 157 lb Conc. Load at 22.37,24.37,26.37,28.37 30.37,32.37,34.37,36.37,38.37,40.37,42.37 TC: 534 lb Conc. Load at 44.52 BC: 427 lb Conc. Load at 6.34 BC: 86 lb Conc. Load at 8.37,10.37,12.37,14.37 16.37,18.37,20.37 BC: 117 lb Conc. Load at 22.37,24.37,26.37,28.37 30.37,32.37,34.37,36.37,38.37,40.37,42.37 BC: 484 lb Conc. Load at 44.52 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T2 Ply: 2 Qty:1 SEQN:178411 HIPS FROM: Page 2 of 2 Cust: R 761 JRef:1X6V7610023 T47 DrwNo:187.21.1739.49347 SSB /WHK 07/06/2021 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 6.31 TC: From 28 plf at 6.31 to 28 plf at 44.69 TC: From 55 plf at 44.69 to 55 plf at 52.00 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 6.34 BC: From 10 plf at 6.34 to 10 plf at 44.52 BC: From 20 plf at 44.52 to 20 plf at 51.00 BC: From 4 plf at 51.00 to 4 plf at 52.00 TC: 300 lb Conc. Load at 6.34 TC: 172 lb Conc. Load at 8.37,10.37,12.37,14.37 16.37,18.37,20.37 TC: 157 lb Conc. Load at 22.37,24.37,26.37,28.37 30.37,32.37,34.37,36.37,38.37,40.37,42.37 TC: 534 lb Conc. Load at 44.52 BC: 427 lb Conc. Load at 6.34 BC: 86 lb Conc. Load at 8.37,10.37,12.37,14.37 16.37,18.37,20.37 BC: 117 lb Conc. Load at 22.37,24.37,26.37,28.37 30.37,32.37,34.37,36.37,38.37,40.37,42.37 BC: 484 lb Conc. Load at 44.52 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T2 Ply: 2 Qty:1 SEQN:178411 HIPS FROM: Page 2 of 2 Cust: R 761 JRef:1X6V7610023 T47 DrwNo:187.21.1739.49347 SSB /WHK 07/06/2021 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Stack Chord: T1 2x4 SP #2; Lt Bearing Leg: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Plating Notes All plates are 1.5X4 except as noted. (**) 3 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Bottom chord section directly below beam pocket bearing(s) shall be cut out prior to installing truss. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AD 921 /-/-/614 /550 /192 AC 1995 /-/-/983 /1152 /- AE 1063 /-/-/717 /632 /- Wind reactions based on MWFRS AD Brg Width = 7.6 Min Req =1.5 AC Brg Width = 3.5 Min Req =1.5 AE Brg Width = 7.6 Min Req =1.5 Bearings AD, AC, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 2144 -1197 AA- D 1717 -2388 C -AA 1523 -972 D - E 1021 -1609 Chords Tens.Comp. E - F 976 -1467 J - K 892 -1284 K - L 1197 -1806 L - M 1074 -1821 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. C -AA 1374 -685 AA- Y 1681 -885 Y - X 1680 -884 X - W 1474 -746 W -T 1457 -757 Chords Tens.Comp. R - Q 1247 -652 Q - P 1806 -978 P - O 1602 -849 O - M 1597 -851 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - X 395 -145 F - T 733 -1314 T - H 919 -491 H -AC 531 -943 I -AC 877 -441 Webs Tens.Comp. AC- I 765 -1210 AC- R 877 -441 R - J 903 -1595 J - Q 527 -139 Q - K 372 -642 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.10 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.161 D 999 360 VERT(CL):0.306 D 915 240 HORZ(LL):0.081 V - - HORZ(TL):0.156 V - - Creep Factor: 2.0 Max TC CSI:0.972 Max BC CSI:0.666 Max Web CSI:0.656 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T3 Ply: 1 Qty:1 SEQN:178418 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T24 DrwNo:187.21.1739.51537 SSB /WHK 07/06/2021 23'7"4 27'4"12 2"10 2"10 6'3"12 6'1"2 8'3"12 2' 15'3" 6'11"4 21'9" 6'6" 23'6"4 1'9"4 30'0"12 6'6"8 36'2"12 6'2" 42'8"4 6'5"8 51' 8'3"12 2'8"6 2'8"6 6'5"8 3'9"2 8'3"12 1'10"4 14'11"8 6'7"12 21'7"4 6'7"12 23'0"4 1'5" 24'2"4 1'2" 30'4"4 6'2" 36'6"4 6'2" 42'6"8 6'0"4 51' 8'5"81'1' 3'4" (NNL) 6"3 2'9"15 8"3'11"124'2"6(a)(a) 8'1" 9'0"4ABC D E F G H I J K L M N OPQRSTUVWXYZAAAB AC AD AE 5 12 3X5(C3)3X4(C3) 3X4(**) 4X12(**) 3X4(**) 3X3 3X3 3X8 5X8 5X6 3X4 5X6 6X8 4X16 3X10 3X44X5 5X6 3X4 3X4 5X6 5X8 4X5(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Stack Chord: T1 2x4 SP #2; Lt Bearing Leg: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Plating Notes All plates are 1.5X4 except as noted. (**) 3 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Bottom chord section directly below beam pocket bearing(s) shall be cut out prior to installing truss. WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AD 921 /-/-/614 /550 /192 AC 1995 /-/-/983 /1152 /- AE 1063 /-/-/717 /632 /- Wind reactions based on MWFRS AD Brg Width = 7.6 Min Req =1.5 AC Brg Width = 3.5 Min Req =1.5 AE Brg Width = 7.6 Min Req =1.5 Bearings AD, AC, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 2144 -1197 AA- D 1717 -2388 C -AA 1523 -972 D - E 1021 -1609 Chords Tens.Comp. E - F 976 -1467 J - K 892 -1284 K - L 1197 -1806 L - M 1074 -1821 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. C -AA 1374 -685 AA- Y 1681 -885 Y - X 1680 -884 X - W 1474 -746 W -T 1457 -757 Chords Tens.Comp. R - Q 1247 -652 Q - P 1806 -978 P - O 1602 -849 O - M 1597 -851 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - X 395 -145 F - T 733 -1314 T - H 919 -491 H -AC 531 -943 I -AC 877 -441 Webs Tens.Comp. AC- I 765 -1210 AC- R 877 -441 R - J 903 -1595 J - Q 527 -139 Q - K 372 -642 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.10 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.161 D 999 360 VERT(CL):0.306 D 915 240 HORZ(LL):0.081 V - - HORZ(TL):0.156 V - - Creep Factor: 2.0 Max TC CSI:0.972 Max BC CSI:0.666 Max Web CSI:0.656 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T3 Ply: 1 Qty:1 SEQN:178418 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T24 DrwNo:187.21.1739.51537 SSB /WHK 07/06/2021 23'7"4 27'4"12 2"10 2"10 6'3"12 6'1"2 8'3"12 2' 15'3" 6'11"4 21'9" 6'6" 23'6"4 1'9"4 30'0"12 6'6"8 36'2"12 6'2" 42'8"4 6'5"8 51' 8'3"12 2'8"6 2'8"6 6'5"8 3'9"2 8'3"12 1'10"4 14'11"8 6'7"12 21'7"4 6'7"12 23'0"4 1'5" 24'2"4 1'2" 30'4"4 6'2" 36'6"4 6'2" 42'6"8 6'0"4 51' 8'5"81'1' 3'4" (NNL) 6"3 2'9"15 8"3'11"124'2"6(a)(a) 8'1" 9'0"4ABC D E F G H I J K L M N OPQRSTUVWXYZAAAB AC AD AE 5 12 3X5(C3)3X4(C3) 3X4(**) 4X12(**) 3X4(**) 3X3 3X3 3X8 5X8 5X6 3X4 5X6 6X8 4X16 3X10 3X44X5 5X6 3X4 3X4 5X6 5X8 4X5(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Plating Notes All plates are 1.5X4 except as noted. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 704 /-/-/488 /373 /229 S 2502 /-/-/1267 /1477 /- AD 906 /-/-/652 /481 /- Wind reactions based on MWFRS AC Brg Width = 7.6 Min Req =1.5 S Brg Width = 3.5 Min Req =2.6 AD Brg Width = 7.6 Min Req =1.5 Bearings AC, S, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1529 -760 AA- D 1194 -1700 B -AC 273 -388 C -AA 1186 -690 D - E 380 -756 F - G 1451 -742 Chords Tens.Comp. G - H 1449 -740 H - I 1642 -833 I - J 535 -203 J - K 469 -877 K - L 636 -1197 L - M 796 -1562 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. C -AA 901 -328 AA- Y 1100 -435 Y - X 1101 -433 X - W 660 -213 W -T 238 -399 Chords Tens.Comp. S - R 316 -568 R - Q 860 -286 Q - P 1060 -362 P - O 1379 -639 O - M 1381 -637 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - X 343 -508 E - W 413 -687 W -F 545 -189 F - T 938 -1584 T - H 560 -251 T - S 1189 -1738 H - S 386 -584 Webs Tens.Comp. S - I 1031 -1732 I - R 785 -352 R - J 624 -1040 J - Q 393 -93 Q - K 222 -376 P - L 308 -377 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.10 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.097 D 999 360 VERT(CL):0.210 D 999 240 HORZ(LL):0.056 O - - HORZ(TL):0.104 O - - Creep Factor: 2.0 Max TC CSI:0.691 Max BC CSI:0.686 Max Web CSI:0.925 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T4 Ply: 1 Qty:1 SEQN:178422 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T42 DrwNo:187.21.1739.53390 SSB /WHK 07/06/2021 23'7"4 27'4"12 2"10 2"10 6'3"12 6'1"2 10'3"12 4' 16'1"4 5'9"8 21'9" 5'7"12 23'5"8 1'8"8 29'1"4 5'7"12 34'9" 5'7"12 40'8"4 5'11"4 45'7"1 4'10"13 51' 5'4"15 2'8"6 2'8"6 6'5"8 3'9"2 10'3"12 3'10"4 15'9"12 5'6" 21'7"4 5'9"8 23'7"4 2' 29'4"12 5'9"8 35'0"8 5'7"12 40'8"4 5'7"12 45'8"13 5'0"9 51' 5'3"31' 1' 3'4" (NNL) 6"3 2'9"15 8"4'9"125'0"6(a)(a) 8'1"A B C D E F G H I J K L M N OPQRSTUVWXYZAAABAC AD 5 12 3X5(C3)3X4(C3) 3X34X8 2X4 3X33X3 3X8 5X8 5X6 3X4 3X5 5X8 5X8 4X8 4X4 3X4 3X4 5X6 5X8 3X4 3X4 3X5(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Plating Notes All plates are 1.5X4 except as noted. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL AC 704 /-/-/488 /373 /229 S 2502 /-/-/1267 /1477 /- AD 906 /-/-/652 /481 /- Wind reactions based on MWFRS AC Brg Width = 7.6 Min Req =1.5 S Brg Width = 3.5 Min Req =2.6 AD Brg Width = 7.6 Min Req =1.5 Bearings AC, S, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1529 -760 AA- D 1194 -1700 B -AC 273 -388 C -AA 1186 -690 D - E 380 -756 F - G 1451 -742 Chords Tens.Comp. G - H 1449 -740 H - I 1642 -833 I - J 535 -203 J - K 469 -877 K - L 636 -1197 L - M 796 -1562 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. C -AA 901 -328 AA- Y 1100 -435 Y - X 1101 -433 X - W 660 -213 W -T 238 -399 Chords Tens.Comp. S - R 316 -568 R - Q 860 -286 Q - P 1060 -362 P - O 1379 -639 O - M 1381 -637 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - X 343 -508 E - W 413 -687 W -F 545 -189 F - T 938 -1584 T - H 560 -251 T - S 1189 -1738 H - S 386 -584 Webs Tens.Comp. S - I 1031 -1732 I - R 785 -352 R - J 624 -1040 J - Q 393 -93 Q - K 222 -376 P - L 308 -377 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.10 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.097 D 999 360 VERT(CL):0.210 D 999 240 HORZ(LL):0.056 O - - HORZ(TL):0.104 O - - Creep Factor: 2.0 Max TC CSI:0.691 Max BC CSI:0.686 Max Web CSI:0.925 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T4 Ply: 1 Qty:1 SEQN:178422 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T42 DrwNo:187.21.1739.53390 SSB /WHK 07/06/2021 23'7"4 27'4"12 2"10 2"10 6'3"12 6'1"2 10'3"12 4' 16'1"4 5'9"8 21'9" 5'7"12 23'5"8 1'8"8 29'1"4 5'7"12 34'9" 5'7"12 40'8"4 5'11"4 45'7"1 4'10"13 51' 5'4"15 2'8"6 2'8"6 6'5"8 3'9"2 10'3"12 3'10"4 15'9"12 5'6" 21'7"4 5'9"8 23'7"4 2' 29'4"12 5'9"8 35'0"8 5'7"12 40'8"4 5'7"12 45'8"13 5'0"9 51' 5'3"31' 1' 3'4" (NNL) 6"3 2'9"15 8"4'9"125'0"6(a)(a) 8'1"A B C D E F G H I J K L M N OPQRSTUVWXYZAAABAC AD 5 12 3X5(C3)3X4(C3) 3X34X8 2X4 3X33X3 3X8 5X8 5X6 3X4 3X5 5X8 5X8 4X8 4X4 3X4 3X4 5X6 5X8 3X4 3X4 3X5(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T5 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 45.84 TC: From 2 plf at 45.84 to 2 plf at 50.67 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 50.67 TC: 178 lb Conc. Load at 45.90,46.94 TC: 296 lb Conc. Load at 48.94 Plating Notes All plates are 3X4 except as noted. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 720 /-/-/-/390 /- S 2512 /-/-/-/1504 /- M 1164 /-/-/-/702 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 S Brg Width = 3.5 Min Req =2.6 M Brg Width = 3.6 Min Req =1.5 Bearings B, S, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 556 -1116 C - D 237 -574 D - E 415 -187 E - F 1285 -795 Chords Tens.Comp. F - G 1285 -795 H - I 363 -785 I - J 656 -1168 J - K 1094 -1771 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - V 969 -457 V - U 965 -459 U - T 470 -159 T - S 202 -440 Chords Tens.Comp. R - Q 763 -352 Q - P 1004 -534 P - O 1869 -1173 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - U 332 -563 D - U 409 -94 D - T 480 -795 T - E 658 -276 E - S 832 -1387 S - G 976 -1594 G - R 805 -379 R - H 613 -971 Webs Tens.Comp. H - Q 450 -204 Q - I 296 -456 I - P 418 -160 P - J 673 -927 J - O 653 -810 O - K 1984 -1225 K - N 709 -1128 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.07 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.065 J 999 360 VERT(CL):0.129 J 999 240 HORZ(LL):0.025 N - - HORZ(TL):0.047 N - - Creep Factor: 2.0 Max TC CSI:0.625 Max BC CSI:0.640 Max Web CSI:0.989 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T5 Ply: 1 Qty:1 SEQN:178445 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T62 DrwNo:187.21.1739.55040 SSB /WHK 07/06/2021 T5 23'7"4 27'0"12 6'4"15 6'4"15 12'3"12 5'10"13 18'2"2 5'10"6 23'7"4 5'5"2 29'0"6 5'5"2 34'7"4 5'6"14 38'8"4 4'1" 45'10"1 7'1"13 50'3"12 4'5"11 50'8" 4"4 6'3"3 6'3"3 12'5"8 6'2"5 17'10"10 5'5"2 23'7"4 5'8"10 29'3"14 5'8"10 34'10"12 5'6"14 38'8"4 3'9"8 46'2"1 7'5"13 50'5"8 4'3"7 50'8" 2"8 1' 6"3 2'8"5'7"125'10"6(a)(a) 8'1"A B C D E F G H I J K L MNOPQRSTUV 5 12 3X5(B1)1.5X4 5X8 5X8 5X6 4X8 3X5 5X6 5X8 5X6 5X6 3X8 4X6 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T5 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 45.84 TC: From 2 plf at 45.84 to 2 plf at 50.67 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 50.67 TC: 178 lb Conc. Load at 45.90,46.94 TC: 296 lb Conc. Load at 48.94 Plating Notes All plates are 3X4 except as noted. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Special care must be taken during handling, shipping and installation of trusses. See "W ARNING" note below. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 720 /-/-/-/390 /- S 2512 /-/-/-/1504 /- M 1164 /-/-/-/702 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 S Brg Width = 3.5 Min Req =2.6 M Brg Width = 3.6 Min Req =1.5 Bearings B, S, & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 556 -1116 C - D 237 -574 D - E 415 -187 E - F 1285 -795 Chords Tens.Comp. F - G 1285 -795 H - I 363 -785 I - J 656 -1168 J - K 1094 -1771 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - V 969 -457 V - U 965 -459 U - T 470 -159 T - S 202 -440 Chords Tens.Comp. R - Q 763 -352 Q - P 1004 -534 P - O 1869 -1173 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - U 332 -563 D - U 409 -94 D - T 480 -795 T - E 658 -276 E - S 832 -1387 S - G 976 -1594 G - R 805 -379 R - H 613 -971 Webs Tens.Comp. H - Q 450 -204 Q - I 296 -456 I - P 418 -160 P - J 673 -927 J - O 653 -810 O - K 1984 -1225 K - N 709 -1128 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 5.07 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.065 J 999 360 VERT(CL):0.129 J 999 240 HORZ(LL):0.025 N - - HORZ(TL):0.047 N - - Creep Factor: 2.0 Max TC CSI:0.625 Max BC CSI:0.640 Max Web CSI:0.989 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T5 Ply: 1 Qty:1 SEQN:178445 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T62 DrwNo:187.21.1739.55040 SSB /WHK 07/06/2021 T5 23'7"4 27'0"12 6'4"15 6'4"15 12'3"12 5'10"13 18'2"2 5'10"6 23'7"4 5'5"2 29'0"6 5'5"2 34'7"4 5'6"14 38'8"4 4'1" 45'10"1 7'1"13 50'3"12 4'5"11 50'8" 4"4 6'3"3 6'3"3 12'5"8 6'2"5 17'10"10 5'5"2 23'7"4 5'8"10 29'3"14 5'8"10 34'10"12 5'6"14 38'8"4 3'9"8 46'2"1 7'5"13 50'5"8 4'3"7 50'8" 2"8 1' 6"3 2'8"5'7"125'10"6(a)(a) 8'1"A B C D E F G H I J K L MNOPQRSTUV 5 12 3X5(B1)1.5X4 5X8 5X8 5X6 4X8 3X5 5X6 5X8 5X6 5X6 3X8 4X6 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 377 /-/-/456 /252 /380 M 1030 /-/0 /782 /683 /0 H 658 /-/-/334 /390 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 338 -740 E - F 409 -689 Chords Tens.Comp. F - G 408 -688 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 632 -371 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 624 -805 L - D 638 -765 D - J 647 -414 Webs Tens.Comp. F - I 372 -383 I - G 837 -497 G - H 408 -608 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.045 K 999 360 VERT(CL):-0.081 K 999 240 HORZ(LL):-0.008 M - - HORZ(TL):0.011 M - - Creep Factor: 2.0 Max TC CSI:0.541 Max BC CSI:0.402 Max Web CSI:0.440 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T6 Ply: 1 Qty:1 SEQN:178512 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T37 DrwNo:187.21.1739.56493 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"10 4'6"10 8'10"10 4'4" 14'3"12 5'5"2 20'4"6 6'0"10 26'5" 6'0"10 9'0"6 9'0"6 14'3"12 5'3"6 20'4"6 6'0"10 26'5" 6'0"101' 6"3 2'4'5"126'5"126'8"68'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X33X4 4X7 3X4 1.5X4 3X8 4X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 377 /-/-/456 /252 /380 M 1030 /-/0 /782 /683 /0 H 658 /-/-/334 /390 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 338 -740 E - F 409 -689 Chords Tens.Comp. F - G 408 -688 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 632 -371 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 624 -805 L - D 638 -765 D - J 647 -414 Webs Tens.Comp. F - I 372 -383 I - G 837 -497 G - H 408 -608 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.045 K 999 360 VERT(CL):-0.081 K 999 240 HORZ(LL):-0.008 M - - HORZ(TL):0.011 M - - Creep Factor: 2.0 Max TC CSI:0.541 Max BC CSI:0.402 Max Web CSI:0.440 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T6 Ply: 1 Qty:1 SEQN:178512 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T37 DrwNo:187.21.1739.56493 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"10 4'6"10 8'10"10 4'4" 14'3"12 5'5"2 20'4"6 6'0"10 26'5" 6'0"10 9'0"6 9'0"6 14'3"12 5'3"6 20'4"6 6'0"10 26'5" 6'0"101' 6"3 2'4'5"126'5"126'8"68'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X33X4 4X7 3X4 1.5X4 3X8 4X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 374 /-/-/455 /252 /431 M 1045 /-/0 /818 /711 /0 H 653 /-/-/345 /392 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 313 -736 E - F 301 -497 Chords Tens.Comp. F - G 301 -497 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 606 -369 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 669 -837 L - D 692 -778 D - J 591 -386 Webs Tens.Comp. I - G 701 -424 G - H 409 -609 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.044 K 999 360 VERT(CL):-0.081 K 999 240 HORZ(LL):-0.009 I - - HORZ(TL):0.013 I - - Creep Factor: 2.0 Max TC CSI:0.545 Max BC CSI:0.467 Max Web CSI:0.418 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T7 Ply: 1 Qty:1 SEQN:178509 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T35 DrwNo:187.21.1739.58290 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"4 4'6"4 8'10"10 4'4"6 16'3"12 7'5"2 21'4"6 5'0"10 26'5" 5'0"10 9'0"6 9'0"6 16'3"12 7'3"6 21'4"6 5'0"10 26'5" 5'0"101' 6"3 2'5'3"127'3"127'6"68'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 5X5 6X6 3X33X4 4X8 3X4 1.5X4 3X8 4X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 374 /-/-/455 /252 /431 M 1045 /-/0 /818 /711 /0 H 653 /-/-/345 /392 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 313 -736 E - F 301 -497 Chords Tens.Comp. F - G 301 -497 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 606 -369 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 669 -837 L - D 692 -778 D - J 591 -386 Webs Tens.Comp. I - G 701 -424 G - H 409 -609 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.044 K 999 360 VERT(CL):-0.081 K 999 240 HORZ(LL):-0.009 I - - HORZ(TL):0.013 I - - Creep Factor: 2.0 Max TC CSI:0.545 Max BC CSI:0.467 Max Web CSI:0.418 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T7 Ply: 1 Qty:1 SEQN:178509 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T35 DrwNo:187.21.1739.58290 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"4 4'6"4 8'10"10 4'4"6 16'3"12 7'5"2 21'4"6 5'0"10 26'5" 5'0"10 9'0"6 9'0"6 16'3"12 7'3"6 21'4"6 5'0"10 26'5" 5'0"101' 6"3 2'5'3"127'3"127'6"68'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 5X5 6X6 3X33X4 4X8 3X4 1.5X4 3X8 4X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 380 /-/-/458 /248 /481 N 1013 /-/0 /819 /684 /0 I 663 /-/-/370 /414 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 N Brg Width = 7.6 Min Req =1.5 I Brg Width = -Min Req =- Bearings B & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. E - F 299 -635 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - K 607 -452 Chords Tens.Comp. K - J 535 -325 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - M 621 -788 M - E 588 -736 Webs Tens.Comp. J - H 648 -418 H - I 429 -623 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.044 L 999 360 VERT(CL):-0.081 L 999 240 HORZ(LL):-0.013 J - - HORZ(TL):0.016 J - - Creep Factor: 2.0 Max TC CSI:0.260 Max BC CSI:0.822 Max Web CSI:0.497 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T8 Ply: 1 Qty:1 SEQN:178505 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T33 DrwNo:187.21.1740.03597 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"4 4'6"4 8'8"14 4'2"10 13'7"3 4'10"5 18'3"12 4'8"9 22'4"6 4'0"10 26'5" 4'0"10 9'0"6 9'0"6 18'3"12 9'3"6 22'4"6 4'0"10 26'5" 4'0"101' 6"3 2'6'1"128'1"128'4"68'1" 10'1" A B C D E F G H IJK L M N 5 12 3X4(B1) 5X5 6X6 1.5X45X5 3X4 4X7 3X4 1.5X4 3X8 4X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 380 /-/-/458 /248 /481 N 1013 /-/0 /819 /684 /0 I 663 /-/-/370 /414 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 N Brg Width = 7.6 Min Req =1.5 I Brg Width = -Min Req =- Bearings B & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. E - F 299 -635 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - K 607 -452 Chords Tens.Comp. K - J 535 -325 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - M 621 -788 M - E 588 -736 Webs Tens.Comp. J - H 648 -418 H - I 429 -623 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.044 L 999 360 VERT(CL):-0.081 L 999 240 HORZ(LL):-0.013 J - - HORZ(TL):0.016 J - - Creep Factor: 2.0 Max TC CSI:0.260 Max BC CSI:0.822 Max Web CSI:0.497 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T8 Ply: 1 Qty:1 SEQN:178505 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T33 DrwNo:187.21.1740.03597 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"4 4'6"4 8'8"14 4'2"10 13'7"3 4'10"5 18'3"12 4'8"9 22'4"6 4'0"10 26'5" 4'0"10 9'0"6 9'0"6 18'3"12 9'3"6 22'4"6 4'0"10 26'5" 4'0"101' 6"3 2'6'1"128'1"128'4"68'1" 10'1" A B C D E F G H IJK L M N 5 12 3X4(B1) 5X5 6X6 1.5X45X5 3X4 4X7 3X4 1.5X4 3X8 4X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 379 /-/-/230 /25 /531 M 1026 /-/0 /729 /753 /0 H 659 /-/-/387 /421 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 130 -427 D - E 238 -750 Chords Tens.Comp. E - F 225 -510 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 646 -443 Chords Tens.Comp. I - H 403 -256 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 637 -798 L - D 653 -756 D - J 646 -455 Webs Tens.Comp. F - I 397 -90 F - H 380 -598 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.021 K 999 360 VERT(CL):-0.058 K 999 240 HORZ(LL):-0.013 H - - HORZ(TL):0.014 H - - Creep Factor: 2.0 Max TC CSI:0.638 Max BC CSI:0.633 Max Web CSI:0.335 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T9 Ply: 1 Qty:1 SEQN:178501 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T36 DrwNo:187.21.1740.04813 SSB /WHK 07/06/2021 8'7"13 17'9"3 4'6"10 4'6"10 8'10"4 4'3"10 14'8"15 5'10"11 20'3"12 5'6"13 26'5" 6'1"4 9'0"6 9'0"6 14'5"7 5'5"1 20'3"12 5'10"5 26'5" 6'1"41' 6"3 2'6'11"128'11"129'2"6(a) 8'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 4X7 3X4 1.5X4 6X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 379 /-/-/230 /25 /531 M 1026 /-/0 /729 /753 /0 H 659 /-/-/387 /421 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 130 -427 D - E 238 -750 Chords Tens.Comp. E - F 225 -510 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 646 -443 Chords Tens.Comp. I - H 403 -256 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 637 -798 L - D 653 -756 D - J 646 -455 Webs Tens.Comp. F - I 397 -90 F - H 380 -598 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.021 K 999 360 VERT(CL):-0.058 K 999 240 HORZ(LL):-0.013 H - - HORZ(TL):0.014 H - - Creep Factor: 2.0 Max TC CSI:0.638 Max BC CSI:0.633 Max Web CSI:0.335 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T9 Ply: 1 Qty:1 SEQN:178501 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T36 DrwNo:187.21.1740.04813 SSB /WHK 07/06/2021 8'7"13 17'9"3 4'6"10 4'6"10 8'10"4 4'3"10 14'8"15 5'10"11 20'3"12 5'6"13 26'5" 6'1"4 9'0"6 9'0"6 14'5"7 5'5"1 20'3"12 5'10"5 26'5" 6'1"41' 6"3 2'6'11"128'11"129'2"6(a) 8'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 4X7 3X4 1.5X4 6X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 377 /-/-/462 /244 /582 M 1033 /-/0 /858 /722 /0 H 656 /-/-/418 /433 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 116 -497 D - E 206 -762 Chords Tens.Comp. E - F 137 -392 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 646 -450 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 660 -812 L - D 679 -763 D - J 643 -461 Webs Tens.Comp. E - I 328 -447 F - I 423 -144 F - H 383 -588 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.042 K 999 360 VERT(CL):-0.081 K 999 240 HORZ(LL):-0.013 H - - HORZ(TL):0.015 H - - Creep Factor: 2.0 Max TC CSI:0.540 Max BC CSI:0.468 Max Web CSI:0.397 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T10 Ply: 1 Qty:1 SEQN:178497 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T34 DrwNo:187.21.1740.06043 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"10 4'6"10 8'10"4 4'3"10 15'8"15 6'10"11 22'3"12 6'6"13 26'5" 4'1"4 9'0"6 9'0"6 15'5"7 6'5"1 22'3"12 6'10"5 26'5" 4'1"41' 6"3 2'7'9"129'9"1210'0"6(a) (a) 8'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 4X7 3X4 1.5X4 6X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 377 /-/-/462 /244 /582 M 1033 /-/0 /858 /722 /0 H 656 /-/-/418 /433 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 7.6 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 116 -497 D - E 206 -762 Chords Tens.Comp. E - F 137 -392 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. J - I 646 -450 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 660 -812 L - D 679 -763 D - J 643 -461 Webs Tens.Comp. E - I 328 -447 F - I 423 -144 F - H 383 -588 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.042 K 999 360 VERT(CL):-0.081 K 999 240 HORZ(LL):-0.013 H - - HORZ(TL):0.015 H - - Creep Factor: 2.0 Max TC CSI:0.540 Max BC CSI:0.468 Max Web CSI:0.397 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T10 Ply: 1 Qty:1 SEQN:178497 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T34 DrwNo:187.21.1740.06043 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"10 4'6"10 8'10"4 4'3"10 15'8"15 6'10"11 22'3"12 6'6"13 26'5" 4'1"4 9'0"6 9'0"6 15'5"7 6'5"1 22'3"12 6'10"5 26'5" 4'1"41' 6"3 2'7'9"129'9"1210'0"6(a) (a) 8'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 4X7 3X4 1.5X4 6X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Bracing (b) scab reinforcement. 80% length of web member. Same size, species & grade or better. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" oc. (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 382 /-/-/465 /239 /632 N 1012 /-/0 /852 /703 /0 I 663 /-/-/455 /457 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 N Brg Width = 7.6 Min Req =1.5 I Brg Width = -Min Req =- Bearings B & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 111 -521 D - E 53 -386 Chords Tens.Comp. E - F 203 -676 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - K 632 -469 Chords Tens.Comp. K - J 470 -347 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - M 636 -788 M - E 580 -755 F - J 395 -504 Webs Tens.Comp. G - J 506 -258 G - I 408 -629 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.042 L 999 360 VERT(CL):-0.081 L 999 240 HORZ(LL):-0.019 I - - HORZ(TL):0.022 I - - Creep Factor: 2.0 Max TC CSI:0.284 Max BC CSI:0.629 Max Web CSI:0.602 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T11 Ply: 1 Qty:1 SEQN:178493 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T30 DrwNo:187.21.1740.07250 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"10 4'6"10 8'8"8 4'1"14 14'1"5 5'4"13 19'4"1 5'2"11 24'3"12 4'11"11 26'5" 2'1"4 9'0"6 9'0"6 16'8"11 7'8"5 24'3"12 7'7"1 26'5" 2'1"41' 6"3 2'8'7"1210'7"1210'10"6(a) (b) 8'1" 10'1" A B C D E F G H IJK L M N 5 12 3X4(B1) 1.5X4 6X6 5X54X4 3X4 3X4 3X4 4X7 3X4 2X4 6X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2700f-2.2E; B2 2x4 SP #2; Webs: 2x4 SP #2; Bracing (b) scab reinforcement. 80% length of web member. Same size, species & grade or better. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" oc. (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 382 /-/-/465 /239 /632 N 1012 /-/0 /852 /703 /0 I 663 /-/-/455 /457 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 N Brg Width = 7.6 Min Req =1.5 I Brg Width = -Min Req =- Bearings B & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 111 -521 D - E 53 -386 Chords Tens.Comp. E - F 203 -676 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - K 632 -469 Chords Tens.Comp. K - J 470 -347 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - M 636 -788 M - E 580 -755 F - J 395 -504 Webs Tens.Comp. G - J 506 -258 G - I 408 -629 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.042 L 999 360 VERT(CL):-0.081 L 999 240 HORZ(LL):-0.019 I - - HORZ(TL):0.022 I - - Creep Factor: 2.0 Max TC CSI:0.284 Max BC CSI:0.629 Max Web CSI:0.602 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T11 Ply: 1 Qty:1 SEQN:178493 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T30 DrwNo:187.21.1740.07250 SSB /WHK 07/06/2021 B2 8'7"13 17'9"3 4'6"10 4'6"10 8'8"8 4'1"14 14'1"5 5'4"13 19'4"1 5'2"11 24'3"12 4'11"11 26'5" 2'1"4 9'0"6 9'0"6 16'8"11 7'8"5 24'3"12 7'7"1 26'5" 2'1"41' 6"3 2'8'7"1210'7"1210'10"6(a) (b) 8'1" 10'1" A B C D E F G H IJK L M N 5 12 3X4(B1) 1.5X4 6X6 5X54X4 3X4 3X4 3X4 4X7 3X4 2X4 6X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (b) scab reinforcement. 80% length of web member. Same size, species & grade or better. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" oc. (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 383 /-/-/224 /-/639 N 1010 /-/0 /737 /746 /0 I 664 /-/-/455 /460 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 N Brg Width = 7.6 Min Req =1.5 I Brg Width = -Min Req =- Bearings B & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 146 -509 Chords Tens.Comp. E - F 198 -678 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - K 634 -472 Chords Tens.Comp. K - J 472 -351 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - M 629 -785 M - E 571 -749 F - J 407 -519 Webs Tens.Comp. G - J 516 -257 G - I 410 -642 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.021 L 999 360 VERT(CL):-0.058 L 999 240 HORZ(LL):-0.020 I - - HORZ(TL):0.023 I - - Creep Factor: 2.0 Max TC CSI:0.313 Max BC CSI:0.637 Max Web CSI:0.597 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T12 Ply: 1 Qty:1 SEQN:178486 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T31 DrwNo:187.21.1740.08353 SSB /WHK 07/06/2021 8'7"13 17'9"3 4'6"10 4'6"10 8'8"8 4'1"14 14'1"5 5'4"13 19'4"1 5'2"11 24'6"12 5'2"11 26'5" 1'10"4 9'0"6 9'0"6 16'8"11 7'8"5 24'6"12 7'10"1 26'5" 1'10"41' 6"3 2'8'9"10'9"10'11"10(a) (a)(b) 8'1" 10'1" A B C D E F G H IJK L M N 5 12 3X4(B1) 1.5X4 6X6 5X54X4 3X4 3X4 3X4 4X7 3X4 2X4 6X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (b) scab reinforcement. 80% length of web member. Same size, species & grade or better. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" oc. (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 383 /-/-/224 /-/639 N 1010 /-/0 /737 /746 /0 I 664 /-/-/455 /460 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 N Brg Width = 7.6 Min Req =1.5 I Brg Width = -Min Req =- Bearings B & N are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 146 -509 Chords Tens.Comp. E - F 198 -678 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - K 634 -472 Chords Tens.Comp. K - J 472 -351 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. N - M 629 -785 M - E 571 -749 F - J 407 -519 Webs Tens.Comp. G - J 516 -257 G - I 410 -642 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.021 L 999 360 VERT(CL):-0.058 L 999 240 HORZ(LL):-0.020 I - - HORZ(TL):0.023 I - - Creep Factor: 2.0 Max TC CSI:0.313 Max BC CSI:0.637 Max Web CSI:0.597 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T12 Ply: 1 Qty:1 SEQN:178486 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T31 DrwNo:187.21.1740.08353 SSB /WHK 07/06/2021 8'7"13 17'9"3 4'6"10 4'6"10 8'8"8 4'1"14 14'1"5 5'4"13 19'4"1 5'2"11 24'6"12 5'2"11 26'5" 1'10"4 9'0"6 9'0"6 16'8"11 7'8"5 24'6"12 7'10"1 26'5" 1'10"41' 6"3 2'8'9"10'9"10'11"10(a) (a)(b) 8'1" 10'1" A B C D E F G H IJK L M N 5 12 3X4(B1) 1.5X4 6X6 5X54X4 3X4 3X4 3X4 4X7 3X4 2X4 6X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 451 /-/-/289 /59 /588 M 918 /-/0 /661 /691 /0 H 676 /-/-/434 /448 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 3.5 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -448 C - D 85 -406 Chords Tens.Comp. D - E 236 -813 E - F 133 -387 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 383 -342 Chords Tens.Comp. J - I 689 -482 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 599 -720 L - D 626 -683 D - J 521 -373 Webs Tens.Comp. E - I 370 -507 F - I 454 -167 F - H 399 -612 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.067 D 999 360 VERT(CL):0.124 D 865 240 HORZ(LL):0.041 H - - HORZ(TL):0.077 H - - Creep Factor: 2.0 Max TC CSI:0.569 Max BC CSI:0.900 Max Web CSI:0.428 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T13 Ply: 1 Qty:1 SEQN:178475 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T23 DrwNo:187.21.1740.09520 SSB /WHK 07/06/2021 8'10"10 17'6"6 4'6"10 4'6"10 8'10"4 4'3"10 15'10"7 7'0"3 22'6"12 6'8"5 26'5" 3'10"4 9'0"6 9'0"6 15'6"15 6'6"9 22'6"12 6'11"13 26'5" 3'10"41' 6"3 2'7'11"9'11"10'1"10(a) (a) 8'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 4X7 3X4 1.5X4 6X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 451 /-/-/289 /59 /588 M 918 /-/0 /661 /691 /0 H 676 /-/-/434 /448 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 3.5 Min Req =1.5 H Brg Width = -Min Req =- Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -448 C - D 85 -406 Chords Tens.Comp. D - E 236 -813 E - F 133 -387 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 383 -342 Chords Tens.Comp. J - I 689 -482 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - L 599 -720 L - D 626 -683 D - J 521 -373 Webs Tens.Comp. E - I 370 -507 F - I 454 -167 F - H 399 -612 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.067 D 999 360 VERT(CL):0.124 D 865 240 HORZ(LL):0.041 H - - HORZ(TL):0.077 H - - Creep Factor: 2.0 Max TC CSI:0.569 Max BC CSI:0.900 Max Web CSI:0.428 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T13 Ply: 1 Qty:1 SEQN:178475 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T23 DrwNo:187.21.1740.09520 SSB /WHK 07/06/2021 8'10"10 17'6"6 4'6"10 4'6"10 8'10"4 4'3"10 15'10"7 7'0"3 22'6"12 6'8"5 26'5" 3'10"4 9'0"6 9'0"6 15'6"15 6'6"9 22'6"12 6'11"13 26'5" 3'10"41' 6"3 2'7'11"9'11"10'1"10(a) (a) 8'1" 10'1" A B C D E F G HIJ K L M 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 4X7 3X4 1.5X4 6X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B1 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 454 /-/-/284 /129 /429 U 1223 /-/0 /860 /847 /0 L 997 /-/-/485 /593 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 U Brg Width = 3.5 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B, U, & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 15 -426 D - E 613 -1237 E - F 659 -1097 Chords Tens.Comp. F - G 586 -812 G - H 585 -809 H - I 309 -468 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 1098 -685 Chords Tens.Comp. Q - N 956 -562 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. U - T 764 -1038 T - D 786 -1005 D - R 972 -613 N - M 448 -249 Webs Tens.Comp. N - H 895 -545 M - H 555 -820 M - I 782 -446 I - L 606 -962 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.088 E 999 360 VERT(CL):0.163 E 999 240 HORZ(LL):0.060 M - - HORZ(TL):0.112 M - - Creep Factor: 2.0 Max TC CSI:0.388 Max BC CSI:0.532 Max Web CSI:0.879 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T14 Ply: 1 Qty:1 SEQN:178519 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T3 DrwNo:187.21.1740.10777 SSB /WHK 07/06/2021 B1 8'10"10 25'7"4"14 4'6"10 4'6"10 8'10"4 4'3"10 14'10"7 6'0"3 20'6"12 5'8"5 26'10"4 6'3"8 30'5"4 3'7" 34'2"2 3'8"14 34'10"8 8"6 9'0"6 9'0"6 14'6"15 5'6"9 20'6"12 5'11"13 26'8"8 6'1"12 30'3"8 3'7" 34'3"14 4'0"6 34'10"8 6"101' 6"3 7'2"132'9'1"9'3"10(a) (a) 8'1"A B C D E F G H I J KLM N OP QR S T U 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 5X8 3X4 1.5X4 6X81.5X4 3X8 5X8 4X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B1 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 454 /-/-/284 /129 /429 U 1223 /-/0 /860 /847 /0 L 997 /-/-/485 /593 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 U Brg Width = 3.5 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B, U, & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 15 -426 D - E 613 -1237 E - F 659 -1097 Chords Tens.Comp. F - G 586 -812 G - H 585 -809 H - I 309 -468 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 1098 -685 Chords Tens.Comp. Q - N 956 -562 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. U - T 764 -1038 T - D 786 -1005 D - R 972 -613 N - M 448 -249 Webs Tens.Comp. N - H 895 -545 M - H 555 -820 M - I 782 -446 I - L 606 -962 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.088 E 999 360 VERT(CL):0.163 E 999 240 HORZ(LL):0.060 M - - HORZ(TL):0.112 M - - Creep Factor: 2.0 Max TC CSI:0.388 Max BC CSI:0.532 Max Web CSI:0.879 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T14 Ply: 1 Qty:1 SEQN:178519 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T3 DrwNo:187.21.1740.10777 SSB /WHK 07/06/2021 B1 8'10"10 25'7"4"14 4'6"10 4'6"10 8'10"4 4'3"10 14'10"7 6'0"3 20'6"12 5'8"5 26'10"4 6'3"8 30'5"4 3'7" 34'2"2 3'8"14 34'10"8 8"6 9'0"6 9'0"6 14'6"15 5'6"9 20'6"12 5'11"13 26'8"8 6'1"12 30'3"8 3'7" 34'3"14 4'0"6 34'10"8 6"101' 6"3 7'2"132'9'1"9'3"10(a) (a) 8'1"A B C D E F G H I J KLM N OP QR S T U 5 12 3X4(B1) 1.5X4 6X6 3X35X5 3X4 3X4 5X8 3X4 1.5X4 6X81.5X4 3X8 5X8 4X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B1 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 456 /-/-/299 /131 /429 W 1221 /-/0 /834 /846 /0 M 998 /-/-/476 /595 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 W Brg Width = 3.5 Min Req =1.5 M Brg Width = 3.5 Min Req =1.5 Bearings B, W, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -427 D - E 573 -1185 E - F 681 -1161 Chords Tens.Comp. F - G 691 -1060 G - H 615 -923 H - I 614 -921 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. T - S 1064 -664 S - R 1021 -619 Chords Tens.Comp. R - O 1062 -638 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. W -V 758 -1032 V - D 776 -1008 D - T 961 -607 O - I 976 -601 Webs Tens.Comp. N - I 589 -836 N - J 882 -511 J - M 592 -993 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.086 E 999 360 VERT(CL):0.161 E 999 240 HORZ(LL):0.058 N - - HORZ(TL):0.109 N - - Creep Factor: 2.0 Max TC CSI:0.312 Max BC CSI:0.532 Max Web CSI:0.933 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T15 Ply: 1 Qty:1 SEQN:178523 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T8 DrwNo:187.21.1740.11963 SSB /WHK 07/06/2021 B1 8'10"10 25'7"4"14 4'6"4 4'6"4 8'10"10 4'4"6 13'10"7 4'11"13 18'6"12 4'8"5 22'11"2 4'4"6 26'10"4 3'11"2 32'5"4 5'7" 34'2"2 1'8"14 34'10"8 8"6 9'0"6 9'0"6 13'6"15 4'6"9 18'6"12 4'11"13 22'7"10 4'0"14 26'8"8 4'0"14 32'3"8 5'7" 34'3"14 2'0"6 34'10"8 6"10 1' 6"3 7'2"132'8'3"8'5"108'1"A B C D E F G H I J K LMN O PQ RST U V W 5 12 3X4(B1) 5X5 6X6 3X33X4 3X4 3X4 5X8 3X4 3X4 3X4 1.5X4 5X81.5X4 3X8 5X8 3X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B1 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 456 /-/-/299 /131 /429 W 1221 /-/0 /834 /846 /0 M 998 /-/-/476 /595 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 W Brg Width = 3.5 Min Req =1.5 M Brg Width = 3.5 Min Req =1.5 Bearings B, W, & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 0 -427 D - E 573 -1185 E - F 681 -1161 Chords Tens.Comp. F - G 691 -1060 G - H 615 -923 H - I 614 -921 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. T - S 1064 -664 S - R 1021 -619 Chords Tens.Comp. R - O 1062 -638 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. W -V 758 -1032 V - D 776 -1008 D - T 961 -607 O - I 976 -601 Webs Tens.Comp. N - I 589 -836 N - J 882 -511 J - M 592 -993 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.086 E 999 360 VERT(CL):0.161 E 999 240 HORZ(LL):0.058 N - - HORZ(TL):0.109 N - - Creep Factor: 2.0 Max TC CSI:0.312 Max BC CSI:0.532 Max Web CSI:0.933 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T15 Ply: 1 Qty:1 SEQN:178523 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T8 DrwNo:187.21.1740.11963 SSB /WHK 07/06/2021 B1 8'10"10 25'7"4"14 4'6"4 4'6"4 8'10"10 4'4"6 13'10"7 4'11"13 18'6"12 4'8"5 22'11"2 4'4"6 26'10"4 3'11"2 32'5"4 5'7" 34'2"2 1'8"14 34'10"8 8"6 9'0"6 9'0"6 13'6"15 4'6"9 18'6"12 4'11"13 22'7"10 4'0"14 26'8"8 4'0"14 32'3"8 5'7" 34'3"14 2'0"6 34'10"8 6"10 1' 6"3 7'2"132'8'3"8'5"108'1"A B C D E F G H I J K LMN O PQ RST U V W 5 12 3X4(B1) 5X5 6X6 3X33X4 3X4 3X4 5X8 3X4 3X4 3X4 1.5X4 5X81.5X4 3X8 5X8 3X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/904 /753 /438 L 1312 /-/-/702 /801 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.6 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1432 -2599 C - D 1315 -2371 D - E 1017 -1702 E - F 1038 -1607 Chords Tens.Comp. F - G 871 -1371 G - H 871 -1371 H - I 528 -846 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2324 -1646 P - O 1965 -1343 Chords Tens.Comp. O - N 1563 -1012 N - M 887 -559 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. P - D 433 -132 D - O 485 -602 E - O 978 -543 O - F 310 -420 Webs Tens.Comp. N - H 816 -527 H - M 748 -996 M - I 1403 -876 I - L 818 -1263 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.160 D 999 360 VERT(CL):0.299 D 999 240 HORZ(LL):-0.052 M - - HORZ(TL):0.093 M - - Creep Factor: 2.0 Max TC CSI:0.735 Max BC CSI:0.999 Max Web CSI:0.889 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T16 Ply: 1 Qty:1 SEQN:178553 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T7 DrwNo:187.21.1740.13280 SSB /WHK 07/06/2021 34'5"10 4"14 5'11"8 5'11"8 11'8" 5'8"8 17'5"4 5'9"4 18'3"12 10"8 23'6"10 5'2"14 28'9"8 5'2"14 34'2"2 5'4"10 34'10"8 8"6 8'9"15 8'9"15 17'5"4 8'7"5 23'6"10 6'1"6 29'1" 5'6"6 34'3"14 5'2"14 34'10"8 6"10 1' 6"3 3"87'9"68'(a)(a)(a) 8'1"A B C D E F G H I J KLMNOP 5 12 4X5(B1) 1.5X4 3X4 5X5 5X5 5X8 5X5 1.5X4 3X8 3X4 4X5 4X5 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/904 /753 /438 L 1312 /-/-/702 /801 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.6 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1432 -2599 C - D 1315 -2371 D - E 1017 -1702 E - F 1038 -1607 Chords Tens.Comp. F - G 871 -1371 G - H 871 -1371 H - I 528 -846 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2324 -1646 P - O 1965 -1343 Chords Tens.Comp. O - N 1563 -1012 N - M 887 -559 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. P - D 433 -132 D - O 485 -602 E - O 978 -543 O - F 310 -420 Webs Tens.Comp. N - H 816 -527 H - M 748 -996 M - I 1403 -876 I - L 818 -1263 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.160 D 999 360 VERT(CL):0.299 D 999 240 HORZ(LL):-0.052 M - - HORZ(TL):0.093 M - - Creep Factor: 2.0 Max TC CSI:0.735 Max BC CSI:0.999 Max Web CSI:0.889 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T16 Ply: 1 Qty:1 SEQN:178553 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T7 DrwNo:187.21.1740.13280 SSB /WHK 07/06/2021 34'5"10 4"14 5'11"8 5'11"8 11'8" 5'8"8 17'5"4 5'9"4 18'3"12 10"8 23'6"10 5'2"14 28'9"8 5'2"14 34'2"2 5'4"10 34'10"8 8"6 8'9"15 8'9"15 17'5"4 8'7"5 23'6"10 6'1"6 29'1" 5'6"6 34'3"14 5'2"14 34'10"8 6"10 1' 6"3 3"87'9"68'(a)(a)(a) 8'1"A B C D E F G H I J KLMNOP 5 12 4X5(B1) 1.5X4 3X4 5X5 5X5 5X8 5X5 1.5X4 3X8 3X4 4X5 4X5 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/889 /764 /388 L 1314 /-/-/682 /810 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.6 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1457 -2606 C - D 1364 -2419 D - E 1123 -1857 E - F 1057 -1648 Chords Tens.Comp. F - G 1146 -1798 G - H 765 -1237 H - I 765 -1237 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2331 -1624 P - O 2057 -1385 Chords Tens.Comp. O - N 1658 -1064 N - M 1721 -1092 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - O 427 -531 E - O 473 -256 N - F 600 -376 N - G 381 -483 Webs Tens.Comp. G - M 442 -653 H - M 441 -463 M - I 1641 -1014 I - L 832 -1257 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.161 D 999 360 VERT(CL):0.300 D 999 240 HORZ(LL):-0.053 M - - HORZ(TL):0.097 M - - Creep Factor: 2.0 Max TC CSI:0.742 Max BC CSI:0.992 Max Web CSI:0.872 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T17 Ply: 1 Qty:1 SEQN:178549 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T19 DrwNo:187.21.1740.14560 SSB /WHK 07/06/2021 34'5"10 4"14 5'3"10 5'3"10 10'5"6 5'1"12 15'6"12 5'1"6 19'3"12 3'9" 20'3"12 1' 27'2"15 6'11"3 34'2"2 6'11"3 34'10"8 8"6 7'10"11 7'10"11 15'6"12 7'8"1 19'2" 3'7"4 27'2"15 8'0"15 34'3"14 7'0"15 34'10"8 6"10 1' 6"3 6'7"7'7'2"10(a)(a) 8'1"A B C D E F G H I J KLMNOP 5 12 4X5(B1) 5X5 3X4 3X4 5X8 5X5 3X8 5X5 5X5 1.5X4 6X8 5X5 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/889 /764 /388 L 1314 /-/-/682 /810 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.6 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1457 -2606 C - D 1364 -2419 D - E 1123 -1857 E - F 1057 -1648 Chords Tens.Comp. F - G 1146 -1798 G - H 765 -1237 H - I 765 -1237 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2331 -1624 P - O 2057 -1385 Chords Tens.Comp. O - N 1658 -1064 N - M 1721 -1092 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - O 427 -531 E - O 473 -256 N - F 600 -376 N - G 381 -483 Webs Tens.Comp. G - M 442 -653 H - M 441 -463 M - I 1641 -1014 I - L 832 -1257 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.161 D 999 360 VERT(CL):0.300 D 999 240 HORZ(LL):-0.053 M - - HORZ(TL):0.097 M - - Creep Factor: 2.0 Max TC CSI:0.742 Max BC CSI:0.992 Max Web CSI:0.872 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T17 Ply: 1 Qty:1 SEQN:178549 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T19 DrwNo:187.21.1740.14560 SSB /WHK 07/06/2021 34'5"10 4"14 5'3"10 5'3"10 10'5"6 5'1"12 15'6"12 5'1"6 19'3"12 3'9" 20'3"12 1' 27'2"15 6'11"3 34'2"2 6'11"3 34'10"8 8"6 7'10"11 7'10"11 15'6"12 7'8"1 19'2" 3'7"4 27'2"15 8'0"15 34'3"14 7'0"15 34'10"8 6"10 1' 6"3 6'7"7'7'2"10(a)(a) 8'1"A B C D E F G H I J KLMNOP 5 12 4X5(B1) 5X5 3X4 3X4 5X8 5X5 3X8 5X5 5X5 1.5X4 6X8 5X5 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2250f-1.9E; B2 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/871 /774 /337 L 1314 /-/-/661 /802 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1434 -2584 C - D 1217 -2059 D - E 1210 -1893 E - F 1210 -1893 Chords Tens.Comp. F - G 1220 -1965 G - H 769 -1261 H - I 769 -1261 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - Q 2310 -1540 Q - P 2308 -1543 P - O 1834 -1167 Chords Tens.Comp. O - N 1801 -1107 N - M 1868 -1158 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - P 415 -524 D - P 408 -150 F - N 480 -234 G - M 528 -825 Webs Tens.Comp. H - M 379 -398 M - I 1677 -1023 I - L 820 -1264 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.147 P 999 360 VERT(CL):0.273 P 999 240 HORZ(LL):0.045 M - - HORZ(TL):0.084 M - - Creep Factor: 2.0 Max TC CSI:0.695 Max BC CSI:0.639 Max Web CSI:0.985 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T18 Ply: 1 Qty:1 SEQN:178545 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T1 DrwNo:187.21.1740.15870 SSB /WHK 07/06/2021 B2 34'5"10 4"14 7'0"7 7'0"7 13'6"12 6'6"5 17'5"4 3'10"8 21'3"12 3'10"8 22'3"12 1' 28'2"15 5'11"3 34'2"2 5'11"3 34'10"8 8"6 6'10"11 6'10"11 13'6"12 6'8"1 17'5"4 3'10"8 21'3"12 3'10"8 28'2"15 6'11"3 34'3"14 6'0"15 34'10"8 6"10 1' 6"3 5'9"6'2"6'4"10(a) 8'1"A B C D E F G H I J KLMNOPQ 5 12 4X5(B1)1.5X4 3X4 5X8 3X4 1.5X4 5X8 5X8 3X4 5X5 1.5X4 5X8 4X5 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2250f-1.9E; B2 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/871 /774 /337 L 1314 /-/-/661 /802 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1434 -2584 C - D 1217 -2059 D - E 1210 -1893 E - F 1210 -1893 Chords Tens.Comp. F - G 1220 -1965 G - H 769 -1261 H - I 769 -1261 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - Q 2310 -1540 Q - P 2308 -1543 P - O 1834 -1167 Chords Tens.Comp. O - N 1801 -1107 N - M 1868 -1158 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - P 415 -524 D - P 408 -150 F - N 480 -234 G - M 528 -825 Webs Tens.Comp. H - M 379 -398 M - I 1677 -1023 I - L 820 -1264 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.147 P 999 360 VERT(CL):0.273 P 999 240 HORZ(LL):0.045 M - - HORZ(TL):0.084 M - - Creep Factor: 2.0 Max TC CSI:0.695 Max BC CSI:0.639 Max Web CSI:0.985 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T18 Ply: 1 Qty:1 SEQN:178545 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T1 DrwNo:187.21.1740.15870 SSB /WHK 07/06/2021 B2 34'5"10 4"14 7'0"7 7'0"7 13'6"12 6'6"5 17'5"4 3'10"8 21'3"12 3'10"8 22'3"12 1' 28'2"15 5'11"3 34'2"2 5'11"3 34'10"8 8"6 6'10"11 6'10"11 13'6"12 6'8"1 17'5"4 3'10"8 21'3"12 3'10"8 28'2"15 6'11"3 34'3"14 6'0"15 34'10"8 6"10 1' 6"3 5'9"6'2"6'4"10(a) 8'1"A B C D E F G H I J KLMNOPQ 5 12 4X5(B1)1.5X4 3X4 5X8 3X4 1.5X4 5X8 5X8 3X4 5X5 1.5X4 5X8 4X5 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2250f-1.9E; B2 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/851 /782 /287 L 1314 /-/-/644 /795 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1458 -2587 C - D 1319 -2218 D - E 1402 -2237 E - F 1402 -2237 Chords Tens.Comp. F - G 1279 -2107 G - H 773 -1280 H - I 773 -1280 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - Q 2316 -1522 Q - P 2316 -1525 P - O 1996 -1255 Chords Tens.Comp. O - N 1959 -1187 N - M 2005 -1221 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. G - M 613 -993 M - I 1709 -1033 Webs Tens.Comp. I - L 810 -1270 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.164 E 999 360 VERT(CL):0.305 E 999 240 HORZ(LL):0.048 M - - HORZ(TL):0.090 M - - Creep Factor: 2.0 Max TC CSI:0.668 Max BC CSI:0.537 Max Web CSI:0.820 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T19 Ply: 1 Qty:1 SEQN:178541 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T2 DrwNo:187.21.1740.17283 SSB /WHK 07/06/2021 B2 34'5"10 4"14 6'0"7 6'0"7 11'6"12 5'6"5 17'5"4 5'10"8 23'3"12 5'10"8 24'3"12 1' 29'2"15 4'11"3 34'2"2 4'11"3 34'10"8 8"6 5'10"11 5'10"11 11'6"12 5'8"1 17'5"4 5'10"8 23'3"12 5'10"8 29'2"15 5'11"3 34'3"14 5'0"15 34'10"8 6"10 1' 6"3 4'11"5'4"5'6"108'1"A B C D E F G H I J KLMNOPQ 5 12 4X5(B1)1.5X4 3X4 5X8 3X4 1.5X4 5X8 5X8 3X4 5X5 1.5X4 5X8 4X5 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP 2250f-1.9E; B2 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/851 /782 /287 L 1314 /-/-/644 /795 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1458 -2587 C - D 1319 -2218 D - E 1402 -2237 E - F 1402 -2237 Chords Tens.Comp. F - G 1279 -2107 G - H 773 -1280 H - I 773 -1280 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - Q 2316 -1522 Q - P 2316 -1525 P - O 1996 -1255 Chords Tens.Comp. O - N 1959 -1187 N - M 2005 -1221 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. G - M 613 -993 M - I 1709 -1033 Webs Tens.Comp. I - L 810 -1270 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.164 E 999 360 VERT(CL):0.305 E 999 240 HORZ(LL):0.048 M - - HORZ(TL):0.090 M - - Creep Factor: 2.0 Max TC CSI:0.668 Max BC CSI:0.537 Max Web CSI:0.820 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T19 Ply: 1 Qty:1 SEQN:178541 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T2 DrwNo:187.21.1740.17283 SSB /WHK 07/06/2021 B2 34'5"10 4"14 6'0"7 6'0"7 11'6"12 5'6"5 17'5"4 5'10"8 23'3"12 5'10"8 24'3"12 1' 29'2"15 4'11"3 34'2"2 4'11"3 34'10"8 8"6 5'10"11 5'10"11 11'6"12 5'8"1 17'5"4 5'10"8 23'3"12 5'10"8 29'2"15 5'11"3 34'3"14 5'0"15 34'10"8 6"10 1' 6"3 4'11"5'4"5'6"108'1"A B C D E F G H I J KLMNOPQ 5 12 4X5(B1)1.5X4 3X4 5X8 3X4 1.5X4 5X8 5X8 3X4 5X5 1.5X4 5X8 4X5 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B1 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/828 /789 /236 M 1314 /-/-/629 /789 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 3.5 Min Req =1.5 Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1554 -2594 C - D 1378 -2355 D - E 1611 -2596 E - F 1596 -2601 Chords Tens.Comp. F - G 1597 -2602 G - H 1351 -2248 H - I 752 -1254 I - J 751 -1253 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - S 2324 -1564 S - R 2136 -1306 R - Q 2615 -1604 Chords Tens.Comp. Q - P 2089 -1254 P - O 2122 -1275 O - N 2123 -1274 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - R 594 -363 Q - G 654 -407 H - N 712 -1186 Webs Tens.Comp. N - J 1705 -1022 J - M 801 -1277 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.199 E 999 360 VERT(CL):0.371 E 999 240 HORZ(LL):0.056 M - - HORZ(TL):0.104 M - - Creep Factor: 2.0 Max TC CSI:0.829 Max BC CSI:0.627 Max Web CSI:0.593 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T20 Ply: 1 Qty:1 SEQN:178537 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T6 DrwNo:187.21.1740.19917 SSB /WHK 07/06/2021 B1 34'5"10 4"14 4'10"11 4'10"11 9'6"12 4'8"1 15'0"1 5'5"5 20'0"3 5'0"1 25'3"12 5'3"9 26'3"12 1' 30'4"11 4'0"15 34'2"2 3'9"7 34'10"8 8"6 9'6"12 9'6"12 14'8"9 5'1"13 20'0"3 5'3"9 25'3"12 5'3"9 26'5"8 1'1"12 30'4"11 3'11"3 34'3"14 3'11"3 34'10"8 6"10 1' 6"3 4'1"4'6"4'8"108'1"A B C D E F G H I J K LMNOPQRS 5 12 4X5(B1) 1.5X4 5X8 3X4 5X5 3X4 1.5X4 5X8 5X8 3X4 5X10(SRS) 1.5X4 1.5X4 5X8 4X5 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B1 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/828 /789 /236 M 1314 /-/-/629 /789 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 M Brg Width = 3.5 Min Req =1.5 Bearings B & M are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1554 -2594 C - D 1378 -2355 D - E 1611 -2596 E - F 1596 -2601 Chords Tens.Comp. F - G 1597 -2602 G - H 1351 -2248 H - I 752 -1254 I - J 751 -1253 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - S 2324 -1564 S - R 2136 -1306 R - Q 2615 -1604 Chords Tens.Comp. Q - P 2089 -1254 P - O 2122 -1275 O - N 2123 -1274 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - R 594 -363 Q - G 654 -407 H - N 712 -1186 Webs Tens.Comp. N - J 1705 -1022 J - M 801 -1277 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.199 E 999 360 VERT(CL):0.371 E 999 240 HORZ(LL):0.056 M - - HORZ(TL):0.104 M - - Creep Factor: 2.0 Max TC CSI:0.829 Max BC CSI:0.627 Max Web CSI:0.593 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T20 Ply: 1 Qty:1 SEQN:178537 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T6 DrwNo:187.21.1740.19917 SSB /WHK 07/06/2021 B1 34'5"10 4"14 4'10"11 4'10"11 9'6"12 4'8"1 15'0"1 5'5"5 20'0"3 5'0"1 25'3"12 5'3"9 26'3"12 1' 30'4"11 4'0"15 34'2"2 3'9"7 34'10"8 8"6 9'6"12 9'6"12 14'8"9 5'1"13 20'0"3 5'3"9 25'3"12 5'3"9 26'5"8 1'1"12 30'4"11 3'11"3 34'3"14 3'11"3 34'10"8 6"10 1' 6"3 4'1"4'6"4'8"108'1"A B C D E F G H I J K LMNOPQRS 5 12 4X5(B1) 1.5X4 5X8 3X4 5X5 3X4 1.5X4 5X8 5X8 3X4 5X10(SRS) 1.5X4 1.5X4 5X8 4X5 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B2,B3 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/803 /795 /186 L 1314 /-/-/626 /785 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.6 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1462 -2558 C - D 1445 -2331 D - E 2002 -3354 E - F 2002 -3354 Chords Tens.Comp. F - G 1334 -2247 G - H 1433 -2423 H - I 1277 -2155 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2276 -1402 P - O 3024 -1863 Chords Tens.Comp. O - N 3002 -1836 N - M 2259 -1342 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - P 641 -230 P - D 543 -852 D - O 404 -208 O - F 435 -192 F - N 640 -919 Webs Tens.Comp. N - G 803 -446 H - M 668 -1060 M - I 2391 -1416 I - L 801 -1255 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.268 E 999 360 VERT(CL):0.499 E 827 240 HORZ(LL):0.059 L - - HORZ(TL):0.110 L - - Creep Factor: 2.0 Max TC CSI:0.781 Max BC CSI:0.907 Max Web CSI:0.848 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T21 Ply: 1 Qty:1 SEQN:178533 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T5 DrwNo:187.21.1742.08850 SSB /WHK 07/06/2021 B2 B3 34'5"10 4"14 7'6"12 7'6"12 12'6"14 5'0"2 17'5"4 4'10"6 22'3"10 4'10"6 27'3"12 5'0"2 28'3"12 1' 34'2"2 5'10"6 34'10"8 8"6 7'10"4 7'10"4 17'5"4 9'7" 27'2" 9'8"12 28'7"4 1'5"4 34'3"14 5'8"10 34'10"8 6"10 1' 6"3 3'3"3'8"3'10"10(a) 8'1"A B C D E F G H I J KLMNOP 5 12 4X5(B1) 5X5 5X5 5X5 1.5X4 5X8 5X5 5X8 5X5 5X5 4X7 4X7 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B2,B3 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1360 /-/-/803 /795 /186 L 1314 /-/-/626 /785 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.6 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1462 -2558 C - D 1445 -2331 D - E 2002 -3354 E - F 2002 -3354 Chords Tens.Comp. F - G 1334 -2247 G - H 1433 -2423 H - I 1277 -2155 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - P 2276 -1402 P - O 3024 -1863 Chords Tens.Comp. O - N 3002 -1836 N - M 2259 -1342 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - P 641 -230 P - D 543 -852 D - O 404 -208 O - F 435 -192 F - N 640 -919 Webs Tens.Comp. N - G 803 -446 H - M 668 -1060 M - I 2391 -1416 I - L 801 -1255 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.268 E 999 360 VERT(CL):0.499 E 827 240 HORZ(LL):0.059 L - - HORZ(TL):0.110 L - - Creep Factor: 2.0 Max TC CSI:0.781 Max BC CSI:0.907 Max Web CSI:0.848 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T21 Ply: 1 Qty:1 SEQN:178533 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T5 DrwNo:187.21.1742.08850 SSB /WHK 07/06/2021 B2 B3 34'5"10 4"14 7'6"12 7'6"12 12'6"14 5'0"2 17'5"4 4'10"6 22'3"10 4'10"6 27'3"12 5'0"2 28'3"12 1' 34'2"2 5'10"6 34'10"8 8"6 7'10"4 7'10"4 17'5"4 9'7" 27'2" 9'8"12 28'7"4 1'5"4 34'3"14 5'8"10 34'10"8 6"10 1' 6"3 3'3"3'8"3'10"10(a) 8'1"A B C D E F G H I J KLMNOP 5 12 4X5(B1) 5X5 5X5 5X5 1.5X4 5X8 5X5 5X8 5X5 5X5 4X7 4X7 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T1,T2 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; W13 2x6 SP #2; Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 5.56 TC: From 28 plf at 5.56 to 28 plf at 29.31 TC: From 55 plf at 29.31 to 55 plf at 34.87 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 5.59 BC: From 10 plf at 5.59 to 10 plf at 29.28 BC: From 20 plf at 29.28 to 20 plf at 34.55 BC: From 4 plf at 34.55 to 4 plf at 34.87 TC: 284 lb Conc. Load at 5.59,29.28 TC: 137 lb Conc. Load at 7.25, 9.25,11.25,13.25 15.25,17.25,19.25,21.25,23.25,25.25,27.25 BC: 314 lb Conc. Load at 5.59,29.28 BC: 103 lb Conc. Load at 7.25, 9.25,11.25,13.25 15.25,17.25,19.25,21.25,23.25,25.25,27.25 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 2824 /-/-/-/1716 /- L 2794 /-/-/-/1691 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1811 -2990 C - D 2645 -4381 D - E 2940 -4869 Chords Tens.Comp. E - F 2940 -4869 F - G 2573 -4262 G - H 1672 -2792 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - R 2709 -1633 R - Q 2718 -1630 Q - P 4439 -2696 P - O 4323 -2625 Chords Tens.Comp. O - N 2610 -1571 N - M 2418 -1454 M - L 2401 -1444 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - Q 1812 -1106 Q - D 446 -512 D - P 470 -268 P - F 597 -345 Webs Tens.Comp. F - O 463 -540 O - G 1800 -1091 N - H 449 -274 H - L 1620 -2696 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.445 E 922 360 VERT(CL):0.807 E 509 240 HORZ(LL):-0.079 C - - HORZ(TL):0.143 C - - Creep Factor: 2.0 Max TC CSI:0.942 Max BC CSI:0.703 Max Web CSI:0.589 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T22 Ply: 2 Qty:1 SEQN:178527 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T16 DrwNo:187.21.1742.11980 SSB /WHK 07/06/2021 2 Complete Trusses Required T1 T2 W13 34'5"10 4"14 5'6"12 5'6"12 11'8"10 6'1"14 17'5"4 5'8"10 23'1"14 5'8"10 29'3"12 6'1"14 30'3"12 1' 34'3"14 4'0"2 34'10"8 6"10 5'8"8 5'8"8 11'5"2 5'8"10 17'5"4 6'0"2 23'5"6 6'0"2 29'3"12 5'10"6 30'5"8 1'1"12 34'1"2 3'7"10 34'10"8 9"6 1' 6"3 2'5"2'10"3'0"108'1"A B C D E F G H I J K LMNOPQR 5 12 4X6(B2) 5X8 1.5X4 5X8 3X4 5X5 3X8 3X4 5X8 5X8 3X4 5X14 1.5X4 1.5X4 3X8 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T1,T2 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; W13 2x6 SP #2; Nailnote Nail Schedule:0.128"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 5.56 TC: From 28 plf at 5.56 to 28 plf at 29.31 TC: From 55 plf at 29.31 to 55 plf at 34.87 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 5.59 BC: From 10 plf at 5.59 to 10 plf at 29.28 BC: From 20 plf at 29.28 to 20 plf at 34.55 BC: From 4 plf at 34.55 to 4 plf at 34.87 TC: 284 lb Conc. Load at 5.59,29.28 TC: 137 lb Conc. Load at 7.25, 9.25,11.25,13.25 15.25,17.25,19.25,21.25,23.25,25.25,27.25 BC: 314 lb Conc. Load at 5.59,29.28 BC: 103 lb Conc. Load at 7.25, 9.25,11.25,13.25 15.25,17.25,19.25,21.25,23.25,25.25,27.25 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Right cantilever is exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 2824 /-/-/-/1716 /- L 2794 /-/-/-/1691 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 L Brg Width = 3.5 Min Req =1.5 Bearings B & L are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1811 -2990 C - D 2645 -4381 D - E 2940 -4869 Chords Tens.Comp. E - F 2940 -4869 F - G 2573 -4262 G - H 1672 -2792 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - R 2709 -1633 R - Q 2718 -1630 Q - P 4439 -2696 P - O 4323 -2625 Chords Tens.Comp. O - N 2610 -1571 N - M 2418 -1454 M - L 2401 -1444 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - Q 1812 -1106 Q - D 446 -512 D - P 470 -268 P - F 597 -345 Webs Tens.Comp. F - O 463 -540 O - G 1800 -1091 N - H 449 -274 H - L 1620 -2696 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.49 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.445 E 922 360 VERT(CL):0.807 E 509 240 HORZ(LL):-0.079 C - - HORZ(TL):0.143 C - - Creep Factor: 2.0 Max TC CSI:0.942 Max BC CSI:0.703 Max Web CSI:0.589 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T22 Ply: 2 Qty:1 SEQN:178527 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T16 DrwNo:187.21.1742.11980 SSB /WHK 07/06/2021 2 Complete Trusses Required T1 T2 W13 34'5"10 4"14 5'6"12 5'6"12 11'8"10 6'1"14 17'5"4 5'8"10 23'1"14 5'8"10 29'3"12 6'1"14 30'3"12 1' 34'3"14 4'0"2 34'10"8 6"10 5'8"8 5'8"8 11'5"2 5'8"10 17'5"4 6'0"2 23'5"6 6'0"2 29'3"12 5'10"6 30'5"8 1'1"12 34'1"2 3'7"10 34'10"8 9"6 1' 6"3 2'5"2'10"3'0"108'1"A B C D E F G H I J K LMNOPQR 5 12 4X6(B2) 5X8 1.5X4 5X8 3X4 5X5 3X8 3X4 5X8 5X8 3X4 5X14 1.5X4 1.5X4 3X8 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at 0.00 to 55 plf at 19.01 TC: From 2 plf at 19.01 to 2 plf at 20.72 BC: From 20 plf at 0.00 to 20 plf at 13.94 BC: From 20 plf at 13.94 to 20 plf at 20.43 TC: 187 lb Conc. Load at 19.08,20.11 Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes Shim all supports to solid bearing. Drop leg is not designed to resist any lateral loading from wind pressure on the wall. End vertical does not provide support for wall. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL L 788 /-/-/-/456 /- G 1050 /-/-/-/519 /- Wind reactions based on MWFRS L Brg Width = -Min Req =- G Brg Width = 6.1 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 418 -730 B - C 570 -999 Chords Tens.Comp. C - D 661 -1120 D - E 980 -1716 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 766 -447 J - I 1509 -854 Chords Tens.Comp. I - H 1136 -661 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - L 473 -750 A - K 969 -556 K - B 422 -529 J - D 340 -616 Webs Tens.Comp. I - E 515 -212 E - H 932 -1578 H - G 519 -1048 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.055 I 999 360 VERT(CL):0.104 I 999 240 HORZ(LL):0.025 H - - HORZ(TL):0.048 H - - Creep Factor: 2.0 Max TC CSI:0.417 Max BC CSI:0.507 Max Web CSI:0.376 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T23 Ply: 1 Qty:1 SEQN:178448 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T40 DrwNo:187.21.1742.24693 SSB /WHK 07/06/2021 20'8"10 5'0"15 5'0"15 9'10"6 4'9"7 13'7"13 3'9"7 19'0"3 5'4"6 20'8"10 1'8"7 4'9"7 4'9"7 9'8"10 4'11"3 13'11"5 4'2"11 20'5"2 6'5"13 20'8"10 3"8 7"131'4"34'5"122'8"2'0"36'5"1210'1" 8'1" A B C D E F GH IJKL 5 12 2.5 12 4X4 1.5X6 3X4 3X4 3X8 4X4 3X4 5X5 5X5(SRS) 4X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at 0.00 to 55 plf at 19.01 TC: From 2 plf at 19.01 to 2 plf at 20.72 BC: From 20 plf at 0.00 to 20 plf at 13.94 BC: From 20 plf at 13.94 to 20 plf at 20.43 TC: 187 lb Conc. Load at 19.08,20.11 Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes Shim all supports to solid bearing. Drop leg is not designed to resist any lateral loading from wind pressure on the wall. End vertical does not provide support for wall. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL L 788 /-/-/-/456 /- G 1050 /-/-/-/519 /- Wind reactions based on MWFRS L Brg Width = -Min Req =- G Brg Width = 6.1 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 418 -730 B - C 570 -999 Chords Tens.Comp. C - D 661 -1120 D - E 980 -1716 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 766 -447 J - I 1509 -854 Chords Tens.Comp. I - H 1136 -661 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - L 473 -750 A - K 969 -556 K - B 422 -529 J - D 340 -616 Webs Tens.Comp. I - E 515 -212 E - H 932 -1578 H - G 519 -1048 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.055 I 999 360 VERT(CL):0.104 I 999 240 HORZ(LL):0.025 H - - HORZ(TL):0.048 H - - Creep Factor: 2.0 Max TC CSI:0.417 Max BC CSI:0.507 Max Web CSI:0.376 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T23 Ply: 1 Qty:1 SEQN:178448 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T40 DrwNo:187.21.1742.24693 SSB /WHK 07/06/2021 20'8"10 5'0"15 5'0"15 9'10"6 4'9"7 13'7"13 3'9"7 19'0"3 5'4"6 20'8"10 1'8"7 4'9"7 4'9"7 9'8"10 4'11"3 13'11"5 4'2"11 20'5"2 6'5"13 20'8"10 3"8 7"131'4"34'5"122'8"2'0"36'5"1210'1" 8'1" A B C D E F GH IJKL 5 12 2.5 12 4X4 1.5X6 3X4 3X4 3X8 4X4 3X4 5X5 5X5(SRS) 4X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T1 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at 0.00 to 55 plf at 19.01 TC: From 2 plf at 19.01 to 2 plf at 20.72 BC: From 20 plf at 0.00 to 20 plf at 13.94 BC: From 20 plf at 13.94 to 20 plf at 20.43 TC: 371 lb Conc. Load at 19.08,20.11 Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes Shim all supports to solid bearing. Drop leg is not designed to resist any lateral loading from wind pressure on the wall. End vertical does not provide support for wall. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 806 /-/-/-/472 /- G 1400 /-/-/-/837 /- Wind reactions based on MWFRS R Brg Width = -Min Req =- G Brg Width = 6.1 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 608 -1052 B - C 1352 -2286 Chords Tens.Comp. C - D 1364 -2292 D - E 1077 -1825 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - J 1085 -640 Chords Tens.Comp. I - H 1404 -904 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Q 503 -737 A - M 1179 -692 R - Q 488 -760 M - B 421 -444 B - J 1336 -781 J - D 496 -296 Webs Tens.Comp. J - I 2025 -1182 D - I 595 -818 I - E 517 -61 E - H 1287 -1970 H - G 836 -1397 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.105 L 999 360 VERT(CL):0.199 L 999 240 HORZ(LL):0.058 H - - HORZ(TL):0.110 H - - Creep Factor: 2.0 Max TC CSI:0.807 Max BC CSI:0.619 Max Web CSI:0.874 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T24 Ply: 1 Qty:1 SEQN:178451 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T27 DrwNo:187.21.1742.49880 SSB /WHK 07/06/2021 T1 20'8"10 7'10"6 7'10"6 12'2"13 4'4"7 13'7"13 1'5" 19'0"3 5'4"6 20'8"10 1'8"7 11"5 11"5 7'6"14 6'7"9 12'1"1 4'6"3 13'11"5 1'10"4 20'5"2 6'5"13 20'8"10 3"8 7"131'4"35'3"122'8"2'0"32'4"37'3"1210'1" 8'1" A B C D E F GH I J KLM NOPQR 5 12 2.5 12 4X4 1.5X6 3X31.5X4 1.5X4 3X5 5X5 6X81.5X4 1.5X4 3X4 5X14 5X5(SRS) 4X5 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; T1 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at 0.00 to 55 plf at 19.01 TC: From 2 plf at 19.01 to 2 plf at 20.72 BC: From 20 plf at 0.00 to 20 plf at 13.94 BC: From 20 plf at 13.94 to 20 plf at 20.43 TC: 371 lb Conc. Load at 19.08,20.11 Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes Shim all supports to solid bearing. Drop leg is not designed to resist any lateral loading from wind pressure on the wall. End vertical does not provide support for wall. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 806 /-/-/-/472 /- G 1400 /-/-/-/837 /- Wind reactions based on MWFRS R Brg Width = -Min Req =- G Brg Width = 6.1 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 608 -1052 B - C 1352 -2286 Chords Tens.Comp. C - D 1364 -2292 D - E 1077 -1825 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - J 1085 -640 Chords Tens.Comp. I - H 1404 -904 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Q 503 -737 A - M 1179 -692 R - Q 488 -760 M - B 421 -444 B - J 1336 -781 J - D 496 -296 Webs Tens.Comp. J - I 2025 -1182 D - I 595 -818 I - E 517 -61 E - H 1287 -1970 H - G 836 -1397 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.105 L 999 360 VERT(CL):0.199 L 999 240 HORZ(LL):0.058 H - - HORZ(TL):0.110 H - - Creep Factor: 2.0 Max TC CSI:0.807 Max BC CSI:0.619 Max Web CSI:0.874 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T24 Ply: 1 Qty:1 SEQN:178451 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T27 DrwNo:187.21.1742.49880 SSB /WHK 07/06/2021 T1 20'8"10 7'10"6 7'10"6 12'2"13 4'4"7 13'7"13 1'5" 19'0"3 5'4"6 20'8"10 1'8"7 11"5 11"5 7'6"14 6'7"9 12'1"1 4'6"3 13'11"5 1'10"4 20'5"2 6'5"13 20'8"10 3"8 7"131'4"35'3"122'8"2'0"32'4"37'3"1210'1" 8'1" A B C D E F GH I J KLM NOPQR 5 12 2.5 12 4X4 1.5X6 3X31.5X4 1.5X4 3X5 5X5 6X81.5X4 1.5X4 3X4 5X14 5X5(SRS) 4X5 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at 0.00 to 55 plf at 19.01 TC: From 2 plf at 19.01 to 2 plf at 20.72 BC: From 20 plf at 0.00 to 20 plf at 13.94 BC: From 20 plf at 13.94 to 20 plf at 20.43 TC: 152 lb Conc. Load at 19.08,20.11 Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes Shim all supports to solid bearing. Drop leg is not designed to resist any lateral loading from wind pressure on the wall. End vertical does not provide support for wall. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 785 /-/-/-/457 /- G 982 /-/-/-/525 /- Wind reactions based on MWFRS R Brg Width = -Min Req =- G Brg Width = 6.1 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 404 -711 B - C 1353 -2264 Chords Tens.Comp. C - D 1295 -2195 D - E 980 -1696 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - J 741 -431 Chords Tens.Comp. I - H 1087 -667 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Q 476 -743 A - M 939 -537 R - Q 462 -765 M - B 433 -487 B - J 1601 -943 J - D 587 -382 Webs Tens.Comp. J - I 1887 -1069 D - I 581 -808 I - E 516 -204 E - H 941 -1508 H - G 524 -980 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.116 L 999 360 VERT(CL):0.222 L 999 240 HORZ(LL):0.055 H - - HORZ(TL):0.105 H - - Creep Factor: 2.0 Max TC CSI:0.588 Max BC CSI:0.500 Max Web CSI:0.496 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T25 Ply: 1 Qty:1 SEQN:178454 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T38 DrwNo:187.21.1743.03987 SSB /WHK 07/06/2021 20'8"10 5'10"6 5'10"6 12'2"13 6'4"7 13'7"13 1'5" 19'0"3 5'4"6 20'8"10 1'8"7 11"5 11"5 5'6"14 4'7"9 12'1"1 6'6"3 13'11"5 1'10"4 20'5"2 6'5"13 20'8"10 3"8 7"131'4"36'1"122'8"2'0"32'4"38'1"12(a) 10'1" 8'1" A B C D E F GH I J KLM NOPQR 512 2.5 12 4X4 1.5X6 3X31.5X4 1.5X4 3X4 5X8 6X81.5X4 1.5X4 3X4 5X14 5X5 4X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at 0.00 to 55 plf at 19.01 TC: From 2 plf at 19.01 to 2 plf at 20.72 BC: From 20 plf at 0.00 to 20 plf at 13.94 BC: From 20 plf at 13.94 to 20 plf at 20.43 TC: 152 lb Conc. Load at 19.08,20.11 Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. End verticals not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes Shim all supports to solid bearing. Drop leg is not designed to resist any lateral loading from wind pressure on the wall. End vertical does not provide support for wall. It is the responsibility of the Building Designer and Truss Fabricator to review this drawing prior to cutting lumber to verify that all data,including dimensions and loads, conform to the architectural plans/specifications and fabricators truss layout. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 785 /-/-/-/457 /- G 982 /-/-/-/525 /- Wind reactions based on MWFRS R Brg Width = -Min Req =- G Brg Width = 6.1 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 404 -711 B - C 1353 -2264 Chords Tens.Comp. C - D 1295 -2195 D - E 980 -1696 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. M - J 741 -431 Chords Tens.Comp. I - H 1087 -667 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Q 476 -743 A - M 939 -537 R - Q 462 -765 M - B 433 -487 B - J 1601 -943 J - D 587 -382 Webs Tens.Comp. J - I 1887 -1069 D - I 581 -808 I - E 516 -204 E - H 941 -1508 H - G 524 -980 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.116 L 999 360 VERT(CL):0.222 L 999 240 HORZ(LL):0.055 H - - HORZ(TL):0.105 H - - Creep Factor: 2.0 Max TC CSI:0.588 Max BC CSI:0.500 Max Web CSI:0.496 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T25 Ply: 1 Qty:1 SEQN:178454 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T38 DrwNo:187.21.1743.03987 SSB /WHK 07/06/2021 20'8"10 5'10"6 5'10"6 12'2"13 6'4"7 13'7"13 1'5" 19'0"3 5'4"6 20'8"10 1'8"7 11"5 11"5 5'6"14 4'7"9 12'1"1 6'6"3 13'11"5 1'10"4 20'5"2 6'5"13 20'8"10 3"8 7"131'4"36'1"122'8"2'0"32'4"38'1"12(a) 10'1" 8'1" A B C D E F GH I J KLM NOPQR 512 2.5 12 4X4 1.5X6 3X31.5X4 1.5X4 3X4 5X8 6X81.5X4 1.5X4 3X4 5X14 5X5 4X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.22" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL S 908 /-/-/587 /582 /531 U 973 /-/-/671 /522 /- Wind reactions based on MWFRS S Brg Width = -Min Req =- U Brg Width = 7.6 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 228 -533 B - C 205 -626 C - D 1357 -3006 Chords Tens.Comp. D - E 1297 -2980 E - F 1138 -2446 F - G 1447 -2932 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - P 445 -142 P - N 588 -184 N - K 1266 -175 Chords Tens.Comp. J - I 2700 -1283 I - G 2675 -1262 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - R 518 -904 A - N 974 -520 S - R 376 -902 N - C 641 -991 C - K 1979 -947 Webs Tens.Comp. K - E 586 -31 K - J 2730 -1006 E - J 305 -888 J - F 426 -425 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.221 E 999 360 VERT(CL):0.413 E 702 240 HORZ(LL):0.133 N - - HORZ(TL):0.212 A - - Creep Factor: 2.0 Max TC CSI:0.564 Max BC CSI:0.812 Max Web CSI:0.805 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T26 Ply: 1 Qty:1 SEQN:178458 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T41 DrwNo:187.21.1743.10553 SSB /WHK 07/06/2021 24'2"2 3'10"6 3'10"6 7'11"11 4'1"5 12'2"13 4'3"1 13'7"13 1'5" 19'2"5 5'6"8 24'2"2 4'11"13 11"5 11"5 3'8"10 2'9"5 12'1"1 8'4"7 13'11"5 1'10"4 19'1"15 5'2"10 23'6"8 4'4"9 24'2"2 7"10 1'2'6'11"126"33'9'2"610'1" 8'1" A B C D E F G HI J K LMN OPQRS U 512 2.5 12 4X4 2X6 3X33X3 2X5 3X8 4X4 4X7 6X8 1.5X4 1.5X4 3X4 8X12(SRS) 5X6 1.5X4 5X8(F3) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.22" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL S 908 /-/-/587 /582 /531 U 973 /-/-/671 /522 /- Wind reactions based on MWFRS S Brg Width = -Min Req =- U Brg Width = 7.6 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 228 -533 B - C 205 -626 C - D 1357 -3006 Chords Tens.Comp. D - E 1297 -2980 E - F 1138 -2446 F - G 1447 -2932 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - P 445 -142 P - N 588 -184 N - K 1266 -175 Chords Tens.Comp. J - I 2700 -1283 I - G 2675 -1262 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - R 518 -904 A - N 974 -520 S - R 376 -902 N - C 641 -991 C - K 1979 -947 Webs Tens.Comp. K - E 586 -31 K - J 2730 -1006 E - J 305 -888 J - F 426 -425 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.221 E 999 360 VERT(CL):0.413 E 702 240 HORZ(LL):0.133 N - - HORZ(TL):0.212 A - - Creep Factor: 2.0 Max TC CSI:0.564 Max BC CSI:0.812 Max Web CSI:0.805 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T26 Ply: 1 Qty:1 SEQN:178458 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T41 DrwNo:187.21.1743.10553 SSB /WHK 07/06/2021 24'2"2 3'10"6 3'10"6 7'11"11 4'1"5 12'2"13 4'3"1 13'7"13 1'5" 19'2"5 5'6"8 24'2"2 4'11"13 11"5 11"5 3'8"10 2'9"5 12'1"1 8'4"7 13'11"5 1'10"4 19'1"15 5'2"10 23'6"8 4'4"9 24'2"2 7"10 1'2'6'11"126"33'9'2"610'1" 8'1" A B C D E F G HI J K LMN OPQRS U 512 2.5 12 4X4 2X6 3X33X3 2X5 3X8 4X4 4X7 6X8 1.5X4 1.5X4 3X4 8X12(SRS) 5X6 1.5X4 5X8(F3) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.22" DL: 0.19". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL T 908 /-/-/620 /596 /582 V 973 /-/-/670 /507 /- Wind reactions based on MWFRS T Brg Width = -Min Req =- V Brg Width = 7.6 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 422 -1236 D - E 1212 -2996 Chords Tens.Comp. E - F 1066 -2441 F - G 1396 -2937 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. S - Q 450 -138 Q - O 630 -195 O - N 1058 0 Chords Tens.Comp. N - K 2740 -807 J - I 2705 -1235 I - G 2680 -1215 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - S 422 -896 A - O 905 -423 T - S 332 -892 O - C 659 -1083 C - N 740 -286 N - D 883 -1793 Webs Tens.Comp. D - K 1269 -508 K - E 625 -40 K - J 2698 -922 E - J 263 -863 J - F 447 -436 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.220 E 999 360 VERT(CL):0.410 E 708 240 HORZ(LL):0.146 N - - HORZ(TL):0.242 A - - Creep Factor: 2.0 Max TC CSI:0.551 Max BC CSI:0.814 Max Web CSI:0.994 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T27 Ply: 1 Qty:1 SEQN:178462 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T45 DrwNo:187.21.1743.14520 SSB /WHK 07/06/2021 24'2"2 1'10"6 1'10"6 6'9"15 4'11"9 12'1"1 5'3"1 13'8"3 1'7"2 19'0"3 5'4" 24'2"2 5'1"15 11"5 11"5 1'8"10 9"5 7'1"7 5'4"13 12'1"1 4'11"9 13'11"5 1'10"4 19'1"15 5'2"10 23'6"8 4'4"9 24'2"2 7"10 1'2'7'9"126"33'10'0"610'1" 8'1" A B C D E F G HI J K LMNO PQRST V 512 2.5 12 3X5 3X5 3X33X3 3X5 4X7 4X4 3X4 4X4 4X5 5X8 1.5X4 5X5 8X12(SRS) 3X4 1.5X4 5X8(F3) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.22" DL: 0.19". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL T 908 /-/-/620 /596 /582 V 973 /-/-/670 /507 /- Wind reactions based on MWFRS T Brg Width = -Min Req =- V Brg Width = 7.6 Min Req =1.5 Bearing G is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 422 -1236 D - E 1212 -2996 Chords Tens.Comp. E - F 1066 -2441 F - G 1396 -2937 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. S - Q 450 -138 Q - O 630 -195 O - N 1058 0 Chords Tens.Comp. N - K 2740 -807 J - I 2705 -1235 I - G 2680 -1215 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - S 422 -896 A - O 905 -423 T - S 332 -892 O - C 659 -1083 C - N 740 -286 N - D 883 -1793 Webs Tens.Comp. D - K 1269 -508 K - E 625 -40 K - J 2698 -922 E - J 263 -863 J - F 447 -436 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.220 E 999 360 VERT(CL):0.410 E 708 240 HORZ(LL):0.146 N - - HORZ(TL):0.242 A - - Creep Factor: 2.0 Max TC CSI:0.551 Max BC CSI:0.814 Max Web CSI:0.994 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T27 Ply: 1 Qty:1 SEQN:178462 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T45 DrwNo:187.21.1743.14520 SSB /WHK 07/06/2021 24'2"2 1'10"6 1'10"6 6'9"15 4'11"9 12'1"1 5'3"1 13'8"3 1'7"2 19'0"3 5'4" 24'2"2 5'1"15 11"5 11"5 1'8"10 9"5 7'1"7 5'4"13 12'1"1 4'11"9 13'11"5 1'10"4 19'1"15 5'2"10 23'6"8 4'4"9 24'2"2 7"10 1'2'7'9"126"33'10'0"610'1" 8'1" A B C D E F G HI J K LMNO PQRST V 512 2.5 12 3X5 3X5 3X33X3 3X5 4X7 4X4 3X4 4X4 4X5 5X8 1.5X4 5X5 8X12(SRS) 3X4 1.5X4 5X8(F3) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Bracing (a) scab reinforcement. 80% length of web member. Same size, species & grade or better. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" oc. (b) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.22" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 908 /-/-/656 /609 /634 T 973 /-/-/633 /503 /- Wind reactions based on MWFRS R Brg Width = -Min Req =- T Brg Width = 7.6 Min Req =1.5 Bearing F is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 293 -1146 C - D 1109 -2997 Chords Tens.Comp. D - E 995 -2442 E - F 1331 -2936 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - O 967 -7 O - M 978 0 M - J 2741 -707 Chords Tens.Comp. I - H 2704 -1169 H - F 2679 -1150 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. R - Q 346 -913 Q - B 682 -1199 B - M 709 -177 M - C 896 -1857 C - J 1271 -497 Webs Tens.Comp. J - D 622 -1 J - I 2702 -840 D - I 230 -865 I - E 452 -434 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.222 D 999 360 VERT(CL):0.415 D 699 240 HORZ(LL):0.245 R - - HORZ(TL):0.275 R - - Creep Factor: 2.0 Max TC CSI:0.604 Max BC CSI:0.814 Max Web CSI:0.610 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T28 Ply: 1 Qty:2 SEQN:178467 MONO FROM: Cust: R 761 JRef:1X6V7610023 T32 DrwNo:187.21.1743.18587 SSB /WHK 07/06/2021 24'2"2 6'3"9 6'3"9 12'1"7 5'9"14 13'7"13 1'6"6 19'0"3 5'4"6 24'2"2 5'1"15 11"5 11"5 6'7"1 5'7"12 12'1"1 5'6" 13'11"5 1'10"4 19'1"15 5'2"10 23'6"8 4'4"9 24'2"2 7"10 1'2'8'7"16"33'10'9"11(a) (b) (b) 10'1" 8'1" A B C D E F GH I J KLM NOPQR T 512 2.5 12 1.5X4 3X5 5X53X33X5 3X4 4X4 5X6 5X8 1.5X4 3X4 8X12(SRS) 3X4 1.5X4 5X8(F3) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Bracing (a) scab reinforcement. 80% length of web member. Same size, species & grade or better. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" oc. (b) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.22" DL: 0.20". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL R 908 /-/-/656 /609 /634 T 973 /-/-/633 /503 /- Wind reactions based on MWFRS R Brg Width = -Min Req =- T Brg Width = 7.6 Min Req =1.5 Bearing F is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 293 -1146 C - D 1109 -2997 Chords Tens.Comp. D - E 995 -2442 E - F 1331 -2936 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Q - O 967 -7 O - M 978 0 M - J 2741 -707 Chords Tens.Comp. I - H 2704 -1169 H - F 2679 -1150 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. R - Q 346 -913 Q - B 682 -1199 B - M 709 -177 M - C 896 -1857 C - J 1271 -497 Webs Tens.Comp. J - D 622 -1 J - I 2702 -840 D - I 230 -865 I - E 452 -434 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.222 D 999 360 VERT(CL):0.415 D 699 240 HORZ(LL):0.245 R - - HORZ(TL):0.275 R - - Creep Factor: 2.0 Max TC CSI:0.604 Max BC CSI:0.814 Max Web CSI:0.610 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T28 Ply: 1 Qty:2 SEQN:178467 MONO FROM: Cust: R 761 JRef:1X6V7610023 T32 DrwNo:187.21.1743.18587 SSB /WHK 07/06/2021 24'2"2 6'3"9 6'3"9 12'1"7 5'9"14 13'7"13 1'6"6 19'0"3 5'4"6 24'2"2 5'1"15 11"5 11"5 6'7"1 5'7"12 12'1"1 5'6" 13'11"5 1'10"4 19'1"15 5'2"10 23'6"8 4'4"9 24'2"2 7"10 1'2'8'7"16"33'10'9"11(a) (b) (b) 10'1" 8'1" A B C D E F GH I J KLM NOPQR T 512 2.5 12 1.5X4 3X5 5X53X33X5 3X4 4X4 5X6 5X8 1.5X4 3X4 8X12(SRS) 3X4 1.5X4 5X8(F3) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.18" DL: 0.16". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL K 908 /-/-/625 /597 /588 M 973 /-/-/670 /505 /- Wind reactions based on MWFRS K Brg Width = -Min Req =- M Brg Width = 7.6 Min Req =1.5 Bearing F is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 466 -1169 D - E 1072 -2449 Chords Tens.Comp. E - F 1378 -2931 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 993 -55 J - I 2149 -742 Chords Tens.Comp. I - H 2697 -1216 H - F 2673 -1197 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. K - C 705 -1129 C - J 695 -232 J - D 739 -1232 Webs Tens.Comp. D - I 691 -252 I - E 420 -417 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.176 I 999 360 VERT(CL):0.328 I 884 240 HORZ(LL):0.097 A - - HORZ(TL):0.180 A - - Creep Factor: 2.0 Max TC CSI:0.601 Max BC CSI:0.811 Max Web CSI:0.901 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T29 Ply: 1 Qty:1 SEQN:178471 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T39 DrwNo:187.21.1743.24070 SSB /WHK 07/06/2021 24'2"2 1'7"6 1'7"6 7'7"9 6'0"3 13'8"3 6'0"10 18'10"15 5'2"12 24'2"2 5'3"3 5"4 5"4 7'11"1 7'5"13 13'11"5 6'0"3 19'0"11 5'1"7 23'6"8 4'5"13 24'2"2 7"10 1'2'7'11"6"3 10'1"10(a) 10'1" 8'1" A B C D E F GH IJK M 512 2.5 12 1.5X4 6X8 4X4 3X4 3X4 5X5 5X5 3X4 1.5X4 5X8(F3) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Rt Slider: 2x4 SP #2; block length = 2.715' Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Deflection Max JT VERT DEFL: LL: 0.18" DL: 0.16". See detail DEFLCAMB1014 for camber recommendations. Provide for adequate drainage of roof. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL K 908 /-/-/625 /597 /588 M 973 /-/-/670 /505 /- Wind reactions based on MWFRS K Brg Width = -Min Req =- M Brg Width = 7.6 Min Req =1.5 Bearing F is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. C - D 466 -1169 D - E 1072 -2449 Chords Tens.Comp. E - F 1378 -2931 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. K - J 993 -55 J - I 2149 -742 Chords Tens.Comp. I - H 2697 -1216 H - F 2673 -1197 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. K - C 705 -1129 C - J 695 -232 J - D 739 -1232 Webs Tens.Comp. D - I 691 -252 I - E 420 -417 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.176 I 999 360 VERT(CL):0.328 I 884 240 HORZ(LL):0.097 A - - HORZ(TL):0.180 A - - Creep Factor: 2.0 Max TC CSI:0.601 Max BC CSI:0.811 Max Web CSI:0.901 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T29 Ply: 1 Qty:1 SEQN:178471 HIPM FROM: Cust: R 761 JRef:1X6V7610023 T39 DrwNo:187.21.1743.24070 SSB /WHK 07/06/2021 24'2"2 1'7"6 1'7"6 7'7"9 6'0"3 13'8"3 6'0"10 18'10"15 5'2"12 24'2"2 5'3"3 5"4 5"4 7'11"1 7'5"13 13'11"5 6'0"3 19'0"11 5'1"7 23'6"8 4'5"13 24'2"2 7"10 1'2'7'11"6"3 10'1"10(a) 10'1" 8'1" A B C D E F GH IJK M 512 2.5 12 1.5X4 6X8 4X4 3X4 3X4 5X5 5X5 3X4 1.5X4 5X8(F3) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP 2250f-1.9E; T3 2x4 SP #2; Bot chord: 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 4.83 TC: From 28 plf at 4.83 to 28 plf at 15.17 TC: From 55 plf at 15.17 to 55 plf at 20.00 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 4.98 BC: From 10 plf at 4.98 to 10 plf at 15.14 BC: From 20 plf at 15.14 to 20 plf at 20.00 TC: 424 lb Conc. Load at 4.98 TC: 118 lb Conc. Load at 7.10, 9.10,11.10,13.10 TC: 306 lb Conc. Load at 15.14 BC: 259 lb Conc. Load at 4.98 BC: 89 lb Conc. Load at 7.10, 9.10,11.10,13.10 BC: 170 lb Conc. Load at 15.14 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1659 /-/-/-/1011 /- J 1505 /-/-/-/899 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 J Brg Width = 7.6 Min Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1981 -3281 C - D 2342 -3882 Chords Tens.Comp. D - E 2341 -3882 E - F 1855 -3069 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2951 -1768 I - H 2968 -1758 Chords Tens.Comp. H - G 2773 -1645 G - F 2761 -1654 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - H 994 -635 D - H 546 -522 Webs Tens.Comp. H - E 1207 -758 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.178 D 999 360 VERT(CL):0.326 D 728 240 HORZ(LL):-0.052 G - - HORZ(TL):0.095 G - - Creep Factor: 2.0 Max TC CSI:0.837 Max BC CSI:0.730 Max Web CSI:0.383 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T30 Ply: 1 Qty:1 SEQN:178557 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T51 DrwNo:187.21.1743.26720 SSB /WHK 07/06/2021 T3 20' 4'10" 4'10" 10' 5'2" 15'2" 5'2" 20' 4'10" 4'11"12 4'11"12 10' 5'0"4 15'0"4 5'0"4 20' 4'11"121' 6"32'6"62'8"158'1"A B C D E F GHI J 5 12 4X6(B2) 6X8 1.5X4 2X4 5X8 1.5X4 6X8 4X6(B2) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP 2250f-1.9E; T3 2x4 SP #2; Bot chord: 2x4 SP 2250f-1.9E; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 4.83 TC: From 28 plf at 4.83 to 28 plf at 15.17 TC: From 55 plf at 15.17 to 55 plf at 20.00 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 4.98 BC: From 10 plf at 4.98 to 10 plf at 15.14 BC: From 20 plf at 15.14 to 20 plf at 20.00 TC: 424 lb Conc. Load at 4.98 TC: 118 lb Conc. Load at 7.10, 9.10,11.10,13.10 TC: 306 lb Conc. Load at 15.14 BC: 259 lb Conc. Load at 4.98 BC: 89 lb Conc. Load at 7.10, 9.10,11.10,13.10 BC: 170 lb Conc. Load at 15.14 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 1659 /-/-/-/1011 /- J 1505 /-/-/-/899 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 J Brg Width = 7.6 Min Req =1.5 Bearings B & F are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 1981 -3281 C - D 2342 -3882 Chords Tens.Comp. D - E 2341 -3882 E - F 1855 -3069 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2951 -1768 I - H 2968 -1758 Chords Tens.Comp. H - G 2773 -1645 G - F 2761 -1654 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - H 994 -635 D - H 546 -522 Webs Tens.Comp. H - E 1207 -758 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.178 D 999 360 VERT(CL):0.326 D 728 240 HORZ(LL):-0.052 G - - HORZ(TL):0.095 G - - Creep Factor: 2.0 Max TC CSI:0.837 Max BC CSI:0.730 Max Web CSI:0.383 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T30 Ply: 1 Qty:1 SEQN:178557 HIPS FROM: Cust: R 761 JRef:1X6V7610023 T51 DrwNo:187.21.1743.26720 SSB /WHK 07/06/2021 T3 20' 4'10" 4'10" 10' 5'2" 15'2" 5'2" 20' 4'10" 4'11"12 4'11"12 10' 5'0"4 15'0"4 5'0"4 20' 4'11"121' 6"32'6"62'8"158'1"A B C D E F GHI J 5 12 4X6(B2) 6X8 1.5X4 2X4 5X8 1.5X4 6X8 4X6(B2) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 21.17 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 21.17 TC: 52 lb Conc. Load at 20.63 BC: 45 lb Conc. Load at 20.63 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 861 /-/-/-/523 /- H 886 /-/-/-/521 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 H Brg Width = 3.5 Min Req =1.5 Bearings B & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 852 -1415 C - D 778 -1337 Chords Tens.Comp. D - E 879 -1472 E - F 1007 -1751 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1238 -722 L - K 1243 -718 Chords Tens.Comp. K - J 1890 -1108 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. K - E 345 -586 E - J 452 -615 Webs Tens.Comp. J - F 1853 -1064 F - I 526 -805 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.081 K 999 360 VERT(CL):0.151 K 999 240 HORZ(LL):0.023 I - - HORZ(TL):0.043 I - - Creep Factor: 2.0 Max TC CSI:0.507 Max BC CSI:0.584 Max Web CSI:0.418 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T31 Ply: 1 Qty:1 SEQN:178561 COMN FROM: Cust: R 761 JRef:1X6V7610023 T54 DrwNo:187.21.1743.29283 SSB /WHK 07/06/2021 21'2" 6'10" 6'10" 13'2" 6'4" 17'6" 4'4" 20'9"12 3'3"12 21'2" 4"4 6'11"12 6'11"12 13'0"4 6'0"8 17'9"8 4'9"4 20'11"8 3'2" 21'2" 2"8 1' 6"3 1'6"113'4"63'6"158'1"A B C D E F G HIJKL 5 12 3X4(B1) 4X7 1.5X4 5X8 5X5 5X5 4X5 4X5 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 55 plf at -1.00 to 55 plf at 21.17 BC: From 4 plf at -1.00 to 4 plf at 0.00 BC: From 20 plf at 0.00 to 20 plf at 21.17 TC: 52 lb Conc. Load at 20.63 BC: 45 lb Conc. Load at 20.63 Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 861 /-/-/-/523 /- H 886 /-/-/-/521 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 H Brg Width = 3.5 Min Req =1.5 Bearings B & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 852 -1415 C - D 778 -1337 Chords Tens.Comp. D - E 879 -1472 E - F 1007 -1751 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1238 -722 L - K 1243 -718 Chords Tens.Comp. K - J 1890 -1108 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. K - E 345 -586 E - J 452 -615 Webs Tens.Comp. J - F 1853 -1064 F - I 526 -805 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Varies by Ld Case FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.081 K 999 360 VERT(CL):0.151 K 999 240 HORZ(LL):0.023 I - - HORZ(TL):0.043 I - - Creep Factor: 2.0 Max TC CSI:0.507 Max BC CSI:0.584 Max Web CSI:0.418 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T31 Ply: 1 Qty:1 SEQN:178561 COMN FROM: Cust: R 761 JRef:1X6V7610023 T54 DrwNo:187.21.1743.29283 SSB /WHK 07/06/2021 21'2" 6'10" 6'10" 13'2" 6'4" 17'6" 4'4" 20'9"12 3'3"12 21'2" 4"4 6'11"12 6'11"12 13'0"4 6'0"8 17'9"8 4'9"4 20'11"8 3'2" 21'2" 2"8 1' 6"3 1'6"113'4"63'6"158'1"A B C D E F G HIJKL 5 12 3X4(B1) 4X7 1.5X4 5X8 5X5 5X5 4X5 4X5 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/516 /498 /165 I 792 /-/-/382 /470 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 I Brg Width = 3.5 Min Req =1.5 Bearings B & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 888 -1451 C - D 701 -1191 D - E 726 -1070 Chords Tens.Comp. E - F 736 -1199 F - G 898 -1533 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 1285 -860 M - L 1057 -587 Chords Tens.Comp. L - K 1601 -955 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. L - F 377 -598 F - K 412 -497 Webs Tens.Comp. K - G 1625 -951 G - J 483 -740 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.074 L 999 360 VERT(CL):0.137 L 999 240 HORZ(LL):-0.021 J - - HORZ(TL):0.037 J - - Creep Factor: 2.0 Max TC CSI:0.501 Max BC CSI:0.659 Max Web CSI:0.522 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T32 Ply: 1 Qty:1 SEQN:178565 COMN FROM: Cust: R 761 JRef:1X6V7610023 T55 DrwNo:187.21.1743.31477 SSB /WHK 07/06/2021 21'2" 4'6"5 4'6"5 8'10" 4'3"11 11'2" 2'4" 15'6" 4'4" 20'9"12 5'3"12 21'2" 4"4 8'10" 8'10" 11'0"4 2'2"4 15'9"8 4'9"4 20'11"8 5'2" 21'2" 2"8 1' 6"3 2'4"114'2"64'4"158'1"A B C D E F G H I JKLM 5 12 3X4(B1) 1.5X4 4X7 3X4 5X8 4X4 5X5 4X5 4X5 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/516 /498 /165 I 792 /-/-/382 /470 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 I Brg Width = 3.5 Min Req =1.5 Bearings B & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 888 -1451 C - D 701 -1191 D - E 726 -1070 Chords Tens.Comp. E - F 736 -1199 F - G 898 -1533 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 1285 -860 M - L 1057 -587 Chords Tens.Comp. L - K 1601 -955 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. L - F 377 -598 F - K 412 -497 Webs Tens.Comp. K - G 1625 -951 G - J 483 -740 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.074 L 999 360 VERT(CL):0.137 L 999 240 HORZ(LL):-0.021 J - - HORZ(TL):0.037 J - - Creep Factor: 2.0 Max TC CSI:0.501 Max BC CSI:0.659 Max Web CSI:0.522 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T32 Ply: 1 Qty:1 SEQN:178565 COMN FROM: Cust: R 761 JRef:1X6V7610023 T55 DrwNo:187.21.1743.31477 SSB /WHK 07/06/2021 21'2" 4'6"5 4'6"5 8'10" 4'3"11 11'2" 2'4" 15'6" 4'4" 20'9"12 5'3"12 21'2" 4"4 8'10" 8'10" 11'0"4 2'2"4 15'9"8 4'9"4 20'11"8 5'2" 21'2" 2"8 1' 6"3 2'4"114'2"64'4"158'1"A B C D E F G H I JKLM 5 12 3X4(B1) 1.5X4 4X7 3X4 5X8 4X4 5X5 4X5 4X5 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/526 /491 /188 I 792 /-/-/386 /476 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 I Brg Width = 3.5 Min Req =1.5 Bearings B & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 810 -1462 C - D 669 -1094 Chords Tens.Comp. D - E 676 -1075 E - F 764 -1307 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 1290 -835 M - L 1288 -838 Chords Tens.Comp. L - K 1333 -788 K - J 834 -539 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - L 553 -289 L - E 270 -481 Webs Tens.Comp. K - F 616 -293 F - J 680 -1040 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.062 L 999 360 VERT(CL):0.115 L 999 240 HORZ(LL):0.023 J - - HORZ(TL):0.043 J - - Creep Factor: 2.0 Max TC CSI:0.410 Max BC CSI:0.643 Max Web CSI:0.402 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T33 Ply: 1 Qty:1 SEQN:178569 COMN FROM: Cust: R 761 JRef:1X6V7610023 T59 DrwNo:187.21.1743.33443 SSB /WHK 07/06/2021 21'2" 5'3"1 5'3"1 10' 4'8"15 13'6" 3'6" 17'3"10 3'9"10 20'11"8 3'7"14 21'2" 2"8 5'1"5 5'1"5 10' 4'10"11 13'9"8 3'9"8 20'9"12 7'0"4 21'2" 4"4 1' 6"3 3'2"114'8"34'10"138'1"A B C D E F G H I JKLM 5 12 3X4(B1)1.5X4 3X4 4X4 5X8 5X5 3X4 3X4 1.5X4 6X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/526 /491 /188 I 792 /-/-/386 /476 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 I Brg Width = 3.5 Min Req =1.5 Bearings B & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 810 -1462 C - D 669 -1094 Chords Tens.Comp. D - E 676 -1075 E - F 764 -1307 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 1290 -835 M - L 1288 -838 Chords Tens.Comp. L - K 1333 -788 K - J 834 -539 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - L 553 -289 L - E 270 -481 Webs Tens.Comp. K - F 616 -293 F - J 680 -1040 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.062 L 999 360 VERT(CL):0.115 L 999 240 HORZ(LL):0.023 J - - HORZ(TL):0.043 J - - Creep Factor: 2.0 Max TC CSI:0.410 Max BC CSI:0.643 Max Web CSI:0.402 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T33 Ply: 1 Qty:1 SEQN:178569 COMN FROM: Cust: R 761 JRef:1X6V7610023 T59 DrwNo:187.21.1743.33443 SSB /WHK 07/06/2021 21'2" 5'3"1 5'3"1 10' 4'8"15 13'6" 3'6" 17'3"10 3'9"10 20'11"8 3'7"14 21'2" 2"8 5'1"5 5'1"5 10' 4'10"11 13'9"8 3'9"8 20'9"12 7'0"4 21'2" 4"4 1' 6"3 3'2"114'8"34'10"138'1"A B C D E F G H I JKLM 5 12 3X4(B1)1.5X4 3X4 4X4 5X8 5X5 3X4 3X4 1.5X4 6X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/547 /484 /235 I 792 /-/-/408 /485 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 I Brg Width = 3.5 Min Req =1.5 Bearings B & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 792 -1459 C - D 643 -1100 D - E 668 -1052 Chords Tens.Comp. E - F 515 -840 F - G 515 -840 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 1288 -869 M - L 1286 -872 Chords Tens.Comp. L - K 1094 -696 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - L 597 -319 K - G 1047 -641 Webs Tens.Comp. G - J 498 -750 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.059 C 999 360 VERT(CL):0.110 C 999 240 HORZ(LL):0.019 J - - HORZ(TL):0.035 J - - Creep Factor: 2.0 Max TC CSI:0.407 Max BC CSI:0.645 Max Web CSI:0.399 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T34 Ply: 1 Qty:1 SEQN:178573 COMN FROM: Cust: R 761 JRef:1X6V7610023 T60 DrwNo:187.21.1743.35530 SSB /WHK 07/06/2021 21'2" 5'3"1 5'3"1 10' 4'8"15 11'6" 1'6" 16'1"14 4'7"14 20'9"12 4'7"14 21'2" 4"4 5'1"5 5'1"5 10' 4'10"11 16'1"14 6'1"14 20'11"8 4'9"10 21'2" 2"8 1' 6"3 4'0"114'8"34'10"138'1"A B C D E F G H I JKLM 5 12 3X4(B1)1.5X4 3X4 4X4 5X8 5X5 1.5X4 3X8 4X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/547 /484 /235 I 792 /-/-/408 /485 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 I Brg Width = 3.5 Min Req =1.5 Bearings B & J are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 792 -1459 C - D 643 -1100 D - E 668 -1052 Chords Tens.Comp. E - F 515 -840 F - G 515 -840 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - M 1288 -869 M - L 1286 -872 Chords Tens.Comp. L - K 1094 -696 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. D - L 597 -319 K - G 1047 -641 Webs Tens.Comp. G - J 498 -750 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.059 C 999 360 VERT(CL):0.110 C 999 240 HORZ(LL):0.019 J - - HORZ(TL):0.035 J - - Creep Factor: 2.0 Max TC CSI:0.407 Max BC CSI:0.645 Max Web CSI:0.399 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T34 Ply: 1 Qty:1 SEQN:178573 COMN FROM: Cust: R 761 JRef:1X6V7610023 T60 DrwNo:187.21.1743.35530 SSB /WHK 07/06/2021 21'2" 5'3"1 5'3"1 10' 4'8"15 11'6" 1'6" 16'1"14 4'7"14 20'9"12 4'7"14 21'2" 4"4 5'1"5 5'1"5 10' 4'10"11 16'1"14 6'1"14 20'11"8 4'9"10 21'2" 2"8 1' 6"3 4'0"114'8"34'10"138'1"A B C D E F G H I JKLM 5 12 3X4(B1)1.5X4 3X4 4X4 5X8 5X5 1.5X4 3X8 4X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/568 /474 /284 H 792 /-/-/426 /494 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 H Brg Width = 3.5 Min Req =1.5 Bearings B & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 763 -1456 C - D 602 -1061 Chords Tens.Comp. D - E 458 -724 E - F 457 -724 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1284 -889 L - K 1282 -891 Chords Tens.Comp. K - J 931 -609 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 314 -391 J - F 958 -605 Webs Tens.Comp. F - I 510 -747 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.057 C 999 360 VERT(CL):0.106 C 999 240 HORZ(LL):-0.018 J - - HORZ(TL):0.033 J - - Creep Factor: 2.0 Max TC CSI:0.413 Max BC CSI:0.633 Max Web CSI:0.487 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T35 Ply: 1 Qty:1 SEQN:178577 COMN FROM: Cust: R 761 JRef:1X6V7610023 T56 DrwNo:187.21.1743.37430 SSB /WHK 07/06/2021 21'2" 5'6"1 5'6"1 10'6" 4'11"15 15'9"10 5'3"10 20'9"12 5'0"2 21'2" 4"4 5'4"5 5'4"5 10'6" 5'1"11 15'9"10 5'3"10 20'11"8 5'1"14 21'2" 2"8 1' 6"3 4'10"115'1"58'1"A B C D E F G HIJKL 5 12 3X4(B1)1.5X4 3X4 4X7 5X5 1.5X4 3X8 4X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/568 /474 /284 H 792 /-/-/426 /494 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 H Brg Width = 3.5 Min Req =1.5 Bearings B & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 763 -1456 C - D 602 -1061 Chords Tens.Comp. D - E 458 -724 E - F 457 -724 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1284 -889 L - K 1282 -891 Chords Tens.Comp. K - J 931 -609 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 314 -391 J - F 958 -605 Webs Tens.Comp. F - I 510 -747 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.057 C 999 360 VERT(CL):0.106 C 999 240 HORZ(LL):-0.018 J - - HORZ(TL):0.033 J - - Creep Factor: 2.0 Max TC CSI:0.413 Max BC CSI:0.633 Max Web CSI:0.487 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T35 Ply: 1 Qty:1 SEQN:178577 COMN FROM: Cust: R 761 JRef:1X6V7610023 T56 DrwNo:187.21.1743.37430 SSB /WHK 07/06/2021 21'2" 5'6"1 5'6"1 10'6" 4'11"15 15'9"10 5'3"10 20'9"12 5'0"2 21'2" 4"4 5'4"5 5'4"5 10'6" 5'1"11 15'9"10 5'3"10 20'11"8 5'1"14 21'2" 2"8 1' 6"3 4'10"115'1"58'1"A B C D E F G HIJKL 5 12 3X4(B1)1.5X4 3X4 4X7 5X5 1.5X4 3X8 4X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/580 /464 /334 H 792 /-/-/448 /508 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 H Brg Width = 3.5 Min Req =1.5 Bearings B & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 724 -1436 C - D 492 -898 Chords Tens.Comp. D - E 337 -518 E - F 337 -518 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1261 -893 L - K 1258 -895 Chords Tens.Comp. K - J 766 -516 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 421 -545 D - K 385 -148 D - J 288 -400 Webs Tens.Comp. J - F 834 -542 F - I 521 -754 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.057 L 999 360 VERT(CL):0.106 L 999 240 HORZ(LL):-0.019 J - - HORZ(TL):0.034 J - - Creep Factor: 2.0 Max TC CSI:0.432 Max BC CSI:0.513 Max Web CSI:0.447 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T36 Ply: 1 Qty:1 SEQN:178581 COMN FROM: Cust: R 761 JRef:1X6V7610023 T57 DrwNo:187.21.1743.38600 SSB /WHK 07/06/2021 21'2" 6'6"1 6'6"1 12'6" 5'11"15 16'9"10 4'3"10 20'9"12 4'0"2 21'2" 4"4 6'4"5 6'4"5 12'6" 6'1"11 16'9"10 4'3"10 20'11"8 4'1"14 21'2" 2"8 1' 6"3 5'8"115'11"58'1"A B C D E F G HIJKL 5 12 3X4(B1)1.5X4 3X4 4X7 5X5 1.5X4 3X8 4X4 1.5X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/580 /464 /334 H 792 /-/-/448 /508 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 H Brg Width = 3.5 Min Req =1.5 Bearings B & I are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 724 -1436 C - D 492 -898 Chords Tens.Comp. D - E 337 -518 E - F 337 -518 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1261 -893 L - K 1258 -895 Chords Tens.Comp. K - J 766 -516 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 421 -545 D - K 385 -148 D - J 288 -400 Webs Tens.Comp. J - F 834 -542 F - I 521 -754 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.057 L 999 360 VERT(CL):0.106 L 999 240 HORZ(LL):-0.019 J - - HORZ(TL):0.034 J - - Creep Factor: 2.0 Max TC CSI:0.432 Max BC CSI:0.513 Max Web CSI:0.447 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T36 Ply: 1 Qty:1 SEQN:178581 COMN FROM: Cust: R 761 JRef:1X6V7610023 T57 DrwNo:187.21.1743.38600 SSB /WHK 07/06/2021 21'2" 6'6"1 6'6"1 12'6" 5'11"15 16'9"10 4'3"10 20'9"12 4'0"2 21'2" 4"4 6'4"5 6'4"5 12'6" 6'1"11 16'9"10 4'3"10 20'11"8 4'1"14 21'2" 2"8 1' 6"3 5'8"115'11"58'1"A B C D E F G HIJKL 5 12 3X4(B1)1.5X4 3X4 4X7 5X5 1.5X4 3X8 4X4 1.5X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/588 /450 /385 G 792 /-/-/473 /520 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 G Brg Width = 3.5 Min Req =1.5 Bearings B & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 678 -1408 Chords Tens.Comp. C - D 352 -724 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1231 -892 J - I 1228 -894 Chords Tens.Comp. I - H 585 -386 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 562 -710 D - I 519 -181 Webs Tens.Comp. D - H 531 -806 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.056 J 999 360 VERT(CL):0.104 J 999 240 HORZ(LL):-0.021 H - - HORZ(TL):0.037 H - - Creep Factor: 2.0 Max TC CSI:0.755 Max BC CSI:0.568 Max Web CSI:0.784 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T37 Ply: 1 Qty:1 SEQN:178585 COMN FROM: Cust: R 761 JRef:1X6V7610023 T58 DrwNo:187.21.1743.40220 SSB /WHK 07/06/2021 21'2" 7'6"1 7'6"1 14'6" 6'11"15 20'11"8 6'5"8 21'2" 2"8 7'4"5 7'4"5 14'6" 7'1"11 20'9"12 6'3"12 21'2" 4"4 1' 6"3 6'6"116'9"5(a) 8'1"A B C D E F GHIJ 5 12 3X4(B1)5X5 3X4 4X7 3X4 1.5X4 6X6 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Bracing (a) 1x4 "T" reinforcement. 80% length of web member. Same species & grade or better, attached with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" oc. or (1) continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels use purlins to brace all flat TC @ 24" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 859 /-/-/588 /450 /385 G 792 /-/-/473 /520 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 G Brg Width = 3.5 Min Req =1.5 Bearings B & H are a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 678 -1408 Chords Tens.Comp. C - D 352 -724 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1231 -892 J - I 1228 -894 Chords Tens.Comp. I - H 585 -386 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 562 -710 D - I 519 -181 Webs Tens.Comp. D - H 531 -806 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.056 J 999 360 VERT(CL):0.104 J 999 240 HORZ(LL):-0.021 H - - HORZ(TL):0.037 H - - Creep Factor: 2.0 Max TC CSI:0.755 Max BC CSI:0.568 Max Web CSI:0.784 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T37 Ply: 1 Qty:1 SEQN:178585 COMN FROM: Cust: R 761 JRef:1X6V7610023 T58 DrwNo:187.21.1743.40220 SSB /WHK 07/06/2021 21'2" 7'6"1 7'6"1 14'6" 6'11"15 20'11"8 6'5"8 21'2" 2"8 7'4"5 7'4"5 14'6" 7'1"11 20'9"12 6'3"12 21'2" 4"4 1' 6"3 6'6"116'9"5(a) 8'1"A B C D E F GHIJ 5 12 3X4(B1)5X5 3X4 4X7 3X4 1.5X4 6X6 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Plating Notes All plates are 1.5X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 10.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Additional Notes See DWGS S18015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL N 423 /-/-/324 /466 /111 J 423 /-/-/324 /466 /- Wind reactions based on MWFRS N Brg Width = 4.0 Min Req =1.5 J Brg Width = 4.0 Min Req =1.5 Bearings N & J are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.026 E 999 360 VERT(CL):0.032 E 999 240 HORZ(LL):0.009 C - - HORZ(TL):0.015 G - - Creep Factor: 2.0 Max TC CSI:0.235 Max BC CSI:0.338 Max Web CSI:0.048 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T38 Ply: 1 Qty:1 SEQN:178438 GABL FROM: Cust: R 761 JRef:1X6V7610023 T26 DrwNo:187.21.1743.41590 SSB /WHK 07/06/2021 1'6'2"1' 1'5"1'4" (TYP) 4'1" 4'1" 8'2" 4'1" 8'2" 8'2"1'1' 6"32'2"102'5"310'9"A B E H I JN 5 12 3X4(B1) 4X4 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Plating Notes All plates are 1.5X4 except as noted. Loading Truss designed to support 1-0-0 top chord outlookers and cladding load not to exceed 10.00 PSF one face and 24.0" span opposite face. Top chord must not be cut or notched, unless specified otherwise. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Additional Notes See DWGS S18015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL N 423 /-/-/324 /466 /111 J 423 /-/-/324 /466 /- Wind reactions based on MWFRS N Brg Width = 4.0 Min Req =1.5 J Brg Width = 4.0 Min Req =1.5 Bearings N & J are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.026 E 999 360 VERT(CL):0.032 E 999 240 HORZ(LL):0.009 C - - HORZ(TL):0.015 G - - Creep Factor: 2.0 Max TC CSI:0.235 Max BC CSI:0.338 Max Web CSI:0.048 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T38 Ply: 1 Qty:1 SEQN:178438 GABL FROM: Cust: R 761 JRef:1X6V7610023 T26 DrwNo:187.21.1743.41590 SSB /WHK 07/06/2021 1'6'2"1' 1'5"1'4" (TYP) 4'1" 4'1" 8'2" 4'1" 8'2" 8'2"1'1' 6"32'2"102'5"310'9"A B E H I JN 5 12 3X4(B1) 4X4 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Plating Notes All plates are 3X4(B1) except as noted. Loading Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Additional Notes See DWGS S18015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 383 /-/-/301 /205 /99 H 383 /-/-/301 /205 /- Wind reactions based on MWFRS G Brg Width = 4.0 Min Req =1.5 H Brg Width = 4.0 Min Req =1.5 Bearings G & H are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.027 C 999 360 VERT(CL):0.050 F 277 240 HORZ(LL):-0.012 C - - HORZ(TL):0.014 C - - Creep Factor: 2.0 Max TC CSI:0.175 Max BC CSI:0.428 Max Web CSI:0.031 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T39 Ply: 1 Qty:1 SEQN:178441 GABL FROM: Cust: R 761 JRef:1X6V7610023 T64 DrwNo:187.21.1743.42980 SSB /WHK 07/06/2021 1'6'2"1' 4'1" 4'1" 8'2" 4'1" 4'1" 4'1" 8'2" 4'1"1'1' 6"32'2"102'5"310'9"A B C D E G H 5 12 4X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Plating Notes All plates are 3X4(B1) except as noted. Loading Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Additional Notes See DWGS S18015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 383 /-/-/301 /205 /99 H 383 /-/-/301 /205 /- Wind reactions based on MWFRS G Brg Width = 4.0 Min Req =1.5 H Brg Width = 4.0 Min Req =1.5 Bearings G & H are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.027 C 999 360 VERT(CL):0.050 F 277 240 HORZ(LL):-0.012 C - - HORZ(TL):0.014 C - - Creep Factor: 2.0 Max TC CSI:0.175 Max BC CSI:0.428 Max Web CSI:0.031 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T39 Ply: 1 Qty:1 SEQN:178441 GABL FROM: Cust: R 761 JRef:1X6V7610023 T64 DrwNo:187.21.1743.42980 SSB /WHK 07/06/2021 1'6'2"1' 4'1" 4'1" 8'2" 4'1" 4'1" 4'1" 8'2" 4'1"1'1' 6"32'2"102'5"310'9"A B C D E G H 5 12 4X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 393 /-/-/289 /221 /99 H 170 /-/-/168 /79 /- I 296 /-/-/273 /207 /- Wind reactions based on MWFRS G Brg Width = 4.0 Min Req =1.5 H Brg Width = 4.0 Min Req =1.5 I Brg Width = 1.5 Min Req =1.5 Bearings G, H, & I are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.030 F 465 360 VERT(CL):0.056 F 249 240 HORZ(LL):-0.007 C - - HORZ(TL):0.013 C - - Creep Factor: 2.0 Max TC CSI:0.181 Max BC CSI:0.454 Max Web CSI:0.027 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T40 Ply: 1 Qty:1 SEQN:178428 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T65 DrwNo:187.21.1743.44243 SSB /WHK 07/06/2021 1'6'8"4 5"12 4'1" 4'1" 8'2" 4'1" 4'1" 4'1" 8'2" 4'1"1'1' 6"32'2"102'5"310'9"A B C D E FG H I 5 12 3X4(B1) 4X4 1.5X4 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 393 /-/-/289 /221 /99 H 170 /-/-/168 /79 /- I 296 /-/-/273 /207 /- Wind reactions based on MWFRS G Brg Width = 4.0 Min Req =1.5 H Brg Width = 4.0 Min Req =1.5 I Brg Width = 1.5 Min Req =1.5 Bearings G, H, & I are a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.030 F 465 360 VERT(CL):0.056 F 249 240 HORZ(LL):-0.007 C - - HORZ(TL):0.013 C - - Creep Factor: 2.0 Max TC CSI:0.181 Max BC CSI:0.454 Max Web CSI:0.027 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T40 Ply: 1 Qty:1 SEQN:178428 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T65 DrwNo:187.21.1743.44243 SSB /WHK 07/06/2021 1'6'8"4 5"12 4'1" 4'1" 8'2" 4'1" 4'1" 4'1" 8'2" 4'1"1'1' 6"32'2"102'5"310'9"A B C D E FG H I 5 12 3X4(B1) 4X4 1.5X4 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 152 /-/-/176 /81 /99 H 371 /-/-/181 /245 /- I 187 /-/-/157 /78 /- J 178 /-80 /-/209 /185 /- Wind reactions based on MWFRS G Brg Width = 1.5 Min Req =1.5 H Brg Width = 1.5 Min Req =1.5 I Brg Width = 1.5 Min Req =1.5 J Brg Width = 1.5 Min Req =1.5 Bearings G, H, I, & J are a rigid surface. Members not listed have forces less than 375# Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 396 -469 Chords Tens.Comp. F - D 403 -478 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 342 -440 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.021 F 946 360 VERT(CL):0.039 F 501 240 HORZ(LL):-0.007 C - - HORZ(TL):0.013 C - - Creep Factor: 2.0 Max TC CSI:0.212 Max BC CSI:0.217 Max Web CSI:0.060 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T41 Ply: 1 Qty:2 SEQN:178425 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T63 DrwNo:187.21.1743.45510 SSB /WHK 07/06/2021 1'6"12 2'0"12 2'2'0"12 5"12 4'1" 4'1" 8'2" 4'1" 4'1" 4'1" 8'2" 4'1"1'1' 6"32'2"102'5"310'9"A B C D E FGH I J 5 12 3X4(B1) 4X4 1.5X4 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL G 152 /-/-/176 /81 /99 H 371 /-/-/181 /245 /- I 187 /-/-/157 /78 /- J 178 /-80 /-/209 /185 /- Wind reactions based on MWFRS G Brg Width = 1.5 Min Req =1.5 H Brg Width = 1.5 Min Req =1.5 I Brg Width = 1.5 Min Req =1.5 J Brg Width = 1.5 Min Req =1.5 Bearings G, H, I, & J are a rigid surface. Members not listed have forces less than 375# Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 396 -469 Chords Tens.Comp. F - D 403 -478 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 342 -440 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.021 F 946 360 VERT(CL):0.039 F 501 240 HORZ(LL):-0.007 C - - HORZ(TL):0.013 C - - Creep Factor: 2.0 Max TC CSI:0.212 Max BC CSI:0.217 Max Web CSI:0.060 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:T41 Ply: 1 Qty:2 SEQN:178425 SPEC FROM: Cust: R 761 JRef:1X6V7610023 T63 DrwNo:187.21.1743.45510 SSB /WHK 07/06/2021 1'6"12 2'0"12 2'2'0"12 5"12 4'1" 4'1" 8'2" 4'1" 4'1" 4'1" 8'2" 4'1"1'1' 6"32'2"102'5"310'9"A B C D E FGH I J 5 12 3X4(B1) 4X4 1.5X4 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See DWGS VALTN160118 and VAL180160118 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL D*75 /-/-/31 /22 /5 Wind reactions based on MWFRS D Brg Width = 46.8 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.004 999 360 VERT(CL):0.008 999 240 HORZ(LL):-0.001 - - HORZ(TL):0.003 - - Creep Factor: 2.0 Max TC CSI:0.061 Max BC CSI:0.094 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:V1 Ply: 1 Qty:1 SEQN:178359 VAL FROM: Cust: R 761 JRef:1X6V7610023 T43 DrwNo:187.21.1743.47550 SSB /WHK 07/06/2021 3'10"13 1'11"6 1'11"6 3'10"13 1'11"6 3'10"13 3'10"13 0"410"12'1"10 A B C D 5 12 3X4(D1) 3X4 3X4(D1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See DWGS VALTN160118 and VAL180160118 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL D*75 /-/-/31 /22 /5 Wind reactions based on MWFRS D Brg Width = 46.8 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.004 999 360 VERT(CL):0.008 999 240 HORZ(LL):-0.001 - - HORZ(TL):0.003 - - Creep Factor: 2.0 Max TC CSI:0.061 Max BC CSI:0.094 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:V1 Ply: 1 Qty:1 SEQN:178359 VAL FROM: Cust: R 761 JRef:1X6V7610023 T43 DrwNo:187.21.1743.47550 SSB /WHK 07/06/2021 3'10"13 1'11"6 1'11"6 3'10"13 1'11"6 3'10"13 3'10"13 0"410"12'1"10 A B C D 5 12 3X4(D1) 3X4 3X4(D1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See DWGS VALTN160118 and VAL180160118 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E*75 /-/-/34 /33 /6 Wind reactions based on MWFRS E Brg Width = 94.8 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.008 D 999 360 VERT(CL):0.014 D 999 240 HORZ(LL):0.003 D - - HORZ(TL):0.005 D - - Creep Factor: 2.0 Max TC CSI:0.152 Max BC CSI:0.150 Max Web CSI:0.036 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:V2 Ply: 1 Qty:1 SEQN:178360 VAL FROM: Cust: R 761 JRef:1X6V7610023 T66 DrwNo:187.21.1743.48710 SSB /WHK 07/06/2021 7'10"13 3'11"6 3'11"6 7'10"13 3'11"6 3'11"6 3'11"6 7'10"13 3'11"6 0"41'8"11'3"10 A B C D E 5 12 3X4(D1) 4X4 1.5X4 3X4(D1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See DWGS VALTN160118 and VAL180160118 for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL E*75 /-/-/34 /33 /6 Wind reactions based on MWFRS E Brg Width = 94.8 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.008 D 999 360 VERT(CL):0.014 D 999 240 HORZ(LL):0.003 D - - HORZ(TL):0.005 D - - Creep Factor: 2.0 Max TC CSI:0.152 Max BC CSI:0.150 Max Web CSI:0.036 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:V2 Ply: 1 Qty:1 SEQN:178360 VAL FROM: Cust: R 761 JRef:1X6V7610023 T66 DrwNo:187.21.1743.48710 SSB /WHK 07/06/2021 7'10"13 3'11"6 3'11"6 7'10"13 3'11"6 3'11"6 3'11"6 7'10"13 3'11"6 0"41'8"11'3"10 A B C D E 5 12 3X4(D1) 4X4 1.5X4 3X4(D1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 307 /-/-/228 /145 /178 D 117 /-/-/65 /-/- C 157 /-/-/102 /174 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.012 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.557 Max BC CSI:0.422 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J1 Ply: 1 Qty:13 SEQN:178355 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T28 DrwNo:187.21.1743.49870 SSB /WHK 07/06/2021 6'3"12 6'3"121' 6"3 3'1"123'4"68'1" 10'11"4 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 307 /-/-/228 /145 /178 D 117 /-/-/65 /-/- C 157 /-/-/102 /174 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.012 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.557 Max BC CSI:0.422 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J1 Ply: 1 Qty:13 SEQN:178355 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T28 DrwNo:187.21.1743.49870 SSB /WHK 07/06/2021 6'3"12 6'3"121' 6"3 3'1"123'4"68'1" 10'11"4 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 307 /-/-/228 /145 /178 E 86 /-/-/50 /2 /- D 172 /-/-/117 /167 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.171 F 434 360 VERT(CL):0.256 F 290 240 HORZ(LL):-0.080 C - - HORZ(TL):0.117 C - - Creep Factor: 2.0 Max TC CSI:0.714 Max BC CSI:0.223 Max Web CSI:0.112 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J2 Ply: 1 Qty:8 SEQN:178369 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T44 DrwNo:187.21.1743.51023 SSB /WHK 07/06/2021 2'4"14 2'4"14 6'3"12 3'10"14 2'8"6 2'8"6 6'3"12 3'7"61' 6"3 8"2'5"123'1"123'4"68'1" 8'9" 10'11"4 A B C D E FGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 307 /-/-/228 /145 /178 E 86 /-/-/50 /2 /- D 172 /-/-/117 /167 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.171 F 434 360 VERT(CL):0.256 F 290 240 HORZ(LL):-0.080 C - - HORZ(TL):0.117 C - - Creep Factor: 2.0 Max TC CSI:0.714 Max BC CSI:0.223 Max Web CSI:0.112 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J2 Ply: 1 Qty:8 SEQN:178369 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T44 DrwNo:187.21.1743.51023 SSB /WHK 07/06/2021 2'4"14 2'4"14 6'3"12 3'10"14 2'8"6 2'8"6 6'3"12 3'7"61' 6"3 8"2'5"123'1"123'4"68'1" 8'9" 10'11"4 A B C D E FGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 279 /-/-/210 /133 /159 D 103 /-/-/57 /-/- C 137 /-/-/89 /153 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.008 D - - HORZ(TL):0.010 D - - Creep Factor: 2.0 Max TC CSI:0.418 Max BC CSI:0.319 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J3 Ply: 1 Qty:13 SEQN:178357 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T18 DrwNo:187.21.1743.52290 SSB /WHK 07/06/2021 5'6"12 5'6"121' 6"3 2'10"3'0"108'1" 10'7"8 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 279 /-/-/210 /133 /159 D 103 /-/-/57 /-/- C 137 /-/-/89 /153 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.008 D - - HORZ(TL):0.010 D - - Creep Factor: 2.0 Max TC CSI:0.418 Max BC CSI:0.319 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J3 Ply: 1 Qty:13 SEQN:178357 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T18 DrwNo:187.21.1743.52290 SSB /WHK 07/06/2021 5'6"12 5'6"121' 6"3 2'10"3'0"108'1" 10'7"8 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 253 /-/-/193 /122 /141 D 89 /-/-/48 /-/- C 118 /-/-/76 /133 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.005 D - - HORZ(TL):0.006 D - - Creep Factor: 2.0 Max TC CSI:0.300 Max BC CSI:0.234 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J4 Ply: 1 Qty:7 SEQN:178356 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T52 DrwNo:187.21.1743.53457 SSB /WHK 07/06/2021 4'10" 4'10"1' 6"3 2'6"62'8"158'1" 10'3"14 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 253 /-/-/193 /122 /141 D 89 /-/-/48 /-/- C 118 /-/-/76 /133 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.005 D - - HORZ(TL):0.006 D - - Creep Factor: 2.0 Max TC CSI:0.300 Max BC CSI:0.234 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J4 Ply: 1 Qty:7 SEQN:178356 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T52 DrwNo:187.21.1743.53457 SSB /WHK 07/06/2021 4'10" 4'10"1' 6"3 2'6"62'8"158'1" 10'3"14 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 173 /-/-/143 /87 /82 D 45 /-/-/23 /-/- C 52 /-/-/30 /64 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 D - - HORZ(TL):0.001 D - - Creep Factor: 2.0 Max TC CSI:0.064 Max BC CSI:0.052 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J5 Ply: 1 Qty:1 SEQN:178381 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T25 DrwNo:187.21.1743.54620 SSB /WHK 07/06/2021 2'6" 2'6"1' 6"3 1'6"111'9"58'1" 9'4"3 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 173 /-/-/143 /87 /82 D 45 /-/-/23 /-/- C 52 /-/-/30 /64 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 D - - HORZ(TL):0.001 D - - Creep Factor: 2.0 Max TC CSI:0.064 Max BC CSI:0.052 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:J5 Ply: 1 Qty:1 SEQN:178381 EJAC FROM: Cust: R 761 JRef:1X6V7610023 T25 DrwNo:187.21.1743.54620 SSB /WHK 07/06/2021 2'6" 2'6"1' 6"3 1'6"111'9"58'1" 9'4"3 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Loading Hipjack supports 6-3-12 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (3) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 272 /-/-/-/165 /- E 250 /-/0 /-/79 /0 D 220 /-/-/-/195 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 374 -617 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - G 577 -350 Chords Tens.Comp. G - F 564 -350 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 388 -621 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.115 F 912 360 VERT(CL):0.215 F 490 240 HORZ(LL):0.022 C - - HORZ(TL):0.041 C - - Creep Factor: 2.0 Max TC CSI:0.611 Max BC CSI:0.866 Max Web CSI:0.117 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K1 Ply: 1 Qty:1 SEQN:178393 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T29 DrwNo:187.21.1743.56000 SSB /WHK 07/06/2021 4'2"15 4'2"15 8'11"2 4'8"3 4'1"3 4'1"3 7'2"2 3'0"15 8'11"2 1'9"1'5" 5"15 3'1"83'4"38'1" 10'11" A B C D EFG 3.54 12 2X4(A1)1.5X4 3X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Loading Hipjack supports 6-3-12 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (3) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 272 /-/-/-/165 /- E 250 /-/0 /-/79 /0 D 220 /-/-/-/195 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 374 -617 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - G 577 -350 Chords Tens.Comp. G - F 564 -350 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 388 -621 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.115 F 912 360 VERT(CL):0.215 F 490 240 HORZ(LL):0.022 C - - HORZ(TL):0.041 C - - Creep Factor: 2.0 Max TC CSI:0.611 Max BC CSI:0.866 Max Web CSI:0.117 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K1 Ply: 1 Qty:1 SEQN:178393 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T29 DrwNo:187.21.1743.56000 SSB /WHK 07/06/2021 4'2"15 4'2"15 8'11"2 4'8"3 4'1"3 4'1"3 7'2"2 3'0"15 8'11"2 1'9"1'5" 5"15 3'1"83'4"38'1" 10'11" A B C D EFG 3.54 12 2X4(A1)1.5X4 3X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Plating Notes All plates are 1.5X4 except as noted. Loading Hipjack supports 6-3-12 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. (3) 16d common (0.162"x3.5") nails at top chord (3) 16d common (0.162"x3.5") nails at bottom chord Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 272 /-/-/-/165 /- G 341 /-/-/-/154 /- F 129 /-/-/-/119 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 G Brg Width = 1.5 Min Req =- F Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 460 -779 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. D - K 638 -369 K - I 747 -436 Chords Tens.Comp. I - H 728 -433 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - H 488 -818 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.073 J 999 360 VERT(CL):0.136 J 777 240 HORZ(LL):0.029 H - - HORZ(TL):0.055 H - - Creep Factor: 2.0 Max TC CSI:0.233 Max BC CSI:0.603 Max Web CSI:0.119 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K2 Ply: 1 Qty:1 SEQN:178398 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T50 DrwNo:187.21.1744.04530 SSB /WHK 07/06/2021 1'5"9 1'5"9 5'10"14 4'5"6 8'11"2 3'0"4 1'5"9 1'5"9 2'1"10 8"2 3'9"13 1'8"2 5'9"2 1'11"6 8'3"1 2'5"15 8'11"2 8"11'5" 5"15 8"2'5"83'1"83'4"38'1" 8'9" 10'11" A B C D E F GHI JKLM 3.54 12 2X4(A1) 3X3 3X4 3X5 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP 2250f-1.9E; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Plating Notes All plates are 1.5X4 except as noted. Loading Hipjack supports 6-3-12 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. (3) 16d common (0.162"x3.5") nails at top chord (3) 16d common (0.162"x3.5") nails at bottom chord Laterally brace top chord below filler and bottom chord above filler at 24" o.c., including a lateral brace at chord ends (If no rigid diaphragm exists at that point). Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 272 /-/-/-/165 /- G 341 /-/-/-/154 /- F 129 /-/-/-/119 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 G Brg Width = 1.5 Min Req =- F Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. D - E 460 -779 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. D - K 638 -369 K - I 747 -436 Chords Tens.Comp. I - H 728 -433 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. E - H 488 -818 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.073 J 999 360 VERT(CL):0.136 J 777 240 HORZ(LL):0.029 H - - HORZ(TL):0.055 H - - Creep Factor: 2.0 Max TC CSI:0.233 Max BC CSI:0.603 Max Web CSI:0.119 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K2 Ply: 1 Qty:1 SEQN:178398 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T50 DrwNo:187.21.1744.04530 SSB /WHK 07/06/2021 1'5"9 1'5"9 5'10"14 4'5"6 8'11"2 3'0"4 1'5"9 1'5"9 2'1"10 8"2 3'9"13 1'8"2 5'9"2 1'11"6 8'3"1 2'5"15 8'11"2 8"11'5" 5"15 8"2'5"83'1"83'4"38'1" 8'9" 10'11" A B C D E F GHI JKLM 3.54 12 2X4(A1) 3X3 3X4 3X5 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Loading Hipjack supports 5-6-12 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 236 /-/-/-/148 /- E 211 /-/0 /-/75 /0 D 147 /-/-/-/133 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 249 -428 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - G 397 -229 Chords Tens.Comp. G - F 390 -231 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 256 -431 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.020 C 999 360 VERT(CL):0.037 C 999 240 HORZ(LL):0.004 C - - HORZ(TL):0.007 C - - Creep Factor: 2.0 Max TC CSI:0.295 Max BC CSI:0.352 Max Web CSI:0.058 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K3 Ply: 1 Qty:2 SEQN:178390 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T20 DrwNo:187.21.1744.07147 SSB /WHK 07/06/2021 4'2"15 4'2"15 7'10"6 3'7"7 4'1"3 4'1"3 7'2"2 3'0"15 7'10"6 8"41'5" 5"15 2'9"123'0"78'1" 10'7"4 A B C D EFG 3.54 12 2X4(A1)1.5X4 3X4 3X3 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Loading Hipjack supports 5-6-12 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 236 /-/-/-/148 /- E 211 /-/0 /-/75 /0 D 147 /-/-/-/133 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. B - C 249 -428 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - G 397 -229 Chords Tens.Comp. G - F 390 -231 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 256 -431 Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):0.020 C 999 360 VERT(CL):0.037 C 999 240 HORZ(LL):0.004 C - - HORZ(TL):0.007 C - - Creep Factor: 2.0 Max TC CSI:0.295 Max BC CSI:0.352 Max Web CSI:0.058 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K3 Ply: 1 Qty:2 SEQN:178390 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T20 DrwNo:187.21.1744.07147 SSB /WHK 07/06/2021 4'2"15 4'2"15 7'10"6 3'7"7 4'1"3 4'1"3 7'2"2 3'0"15 7'10"6 8"41'5" 5"15 2'9"123'0"78'1" 10'7"4 A B C D EFG 3.54 12 2X4(A1)1.5X4 3X4 3X3 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Loading Hipjack supports 4-10-0 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 171 /-/-/-/106 /- D 81 /-/-/14 /-/- C 188 /-/-/-/170 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.008 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.656 Max BC CSI:0.340 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K4 Ply: 1 Qty:2 SEQN:178378 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T53 DrwNo:187.21.1744.08677 SSB /WHK 07/06/2021 6'10" 6'10"1'5" 5"15 2'6"22'8"138'1" 10'3"10 A B C D 3.54 12 2X4(A1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Loading Hipjack supports 4-10-0 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 171 /-/-/-/106 /- D 81 /-/-/14 /-/- C 188 /-/-/-/170 /- Wind reactions based on MWFRS B Brg Width = 10.8 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:0.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: No FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.008 D - - HORZ(TL):0.016 D - - Creep Factor: 2.0 Max TC CSI:0.656 Max BC CSI:0.340 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:K4 Ply: 1 Qty:2 SEQN:178378 HIP_ FROM: Cust: R 761 JRef:1X6V7610023 T53 DrwNo:187.21.1744.08677 SSB /WHK 07/06/2021 6'10" 6'10"1'5" 5"15 2'6"22'8"138'1" 10'3"10 A B C D 3.54 12 2X4(A1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 143 /-/-/133 /90 /44 D 15 /-/-/9 /3 /- C -/-10 /-/29 /31 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.000 C - - HORZ(TL):0.000 C - - Creep Factor: 2.0 Max TC CSI:0.061 Max BC CSI:0.010 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C1 Ply: 1 Qty:5 SEQN:178349 JACK FROM: Cust: R 761 JRef:1X6V7610023 T15 DrwNo:187.21.1744.10227 SSB /WHK 07/06/2021 1' 1'1' 6"3 11"31'1"138'1" 8'8"11 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 143 /-/-/133 /90 /44 D 15 /-/-/9 /3 /- C -/-10 /-/29 /31 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.000 C - - HORZ(TL):0.000 C - - Creep Factor: 2.0 Max TC CSI:0.061 Max BC CSI:0.010 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C1 Ply: 1 Qty:5 SEQN:178349 JACK FROM: Cust: R 761 JRef:1X6V7610023 T15 DrwNo:187.21.1744.10227 SSB /WHK 07/06/2021 1' 1'1' 6"3 11"31'1"138'1" 8'8"11 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 42 /-/-/26 /12 /24 C 17 /-/-/10 /-/- B 23 /-/-/16 /29 /- Wind reactions based on MWFRS A Brg Width = 7.6 Min Req =1.5 C Brg Width = 1.5 Min Req =- B Brg Width = 1.5 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.000 C - - HORZ(TL):0.000 C - - Creep Factor: 2.0 Max TC CSI:0.010 Max BC CSI:0.007 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C1A Ply: 1 Qty:1 SEQN:178358 JACK FROM: Cust: R 761 JRef:1X6V7610023 T9 DrwNo:187.21.1744.11580 SSB /WHK 07/06/2021 1' 1' 6"3 11"38'1" 8'8"11A B C 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 42 /-/-/26 /12 /24 C 17 /-/-/10 /-/- B 23 /-/-/16 /29 /- Wind reactions based on MWFRS A Brg Width = 7.6 Min Req =1.5 C Brg Width = 1.5 Min Req =- B Brg Width = 1.5 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.000 C - - HORZ(TL):0.000 C - - Creep Factor: 2.0 Max TC CSI:0.010 Max BC CSI:0.007 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C1A Ply: 1 Qty:1 SEQN:178358 JACK FROM: Cust: R 761 JRef:1X6V7610023 T9 DrwNo:187.21.1744.11580 SSB /WHK 07/06/2021 1' 1' 6"3 11"38'1" 8'8"11A B C 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 D 54 /-/-/28 /-/- C 67 /-/-/41 /80 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 D - - HORZ(TL):0.001 D - - Creep Factor: 2.0 Max TC CSI:0.089 Max BC CSI:0.080 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C2 Ply: 1 Qty:4 SEQN:178350 JACK FROM: Cust: R 761 JRef:1X6V7610023 T14 DrwNo:187.21.1744.12900 SSB /WHK 07/06/2021 3' 3'1' 6"3 1'9"31'11"138'1" 9'6"11 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 D 54 /-/-/28 /-/- C 67 /-/-/41 /80 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 D - - HORZ(TL):0.001 D - - Creep Factor: 2.0 Max TC CSI:0.089 Max BC CSI:0.080 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C2 Ply: 1 Qty:4 SEQN:178350 JACK FROM: Cust: R 761 JRef:1X6V7610023 T14 DrwNo:187.21.1744.12900 SSB /WHK 07/06/2021 3' 3'1' 6"3 1'9"31'11"138'1" 9'6"11 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 138 /-/-/103 /45 /74 C 42 /-/-/23 /-/- B 76 /-/-/50 /89 /- Wind reactions based on MWFRS A Brg Width = 3.5 Min Req =1.5 C Brg Width = 1.5 Min Req =- B Brg Width = 1.5 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 B - - HORZ(TL):0.002 B - - Creep Factor: 2.0 Max TC CSI:0.115 Max BC CSI:0.067 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C2AC Ply: 1 Qty:1 SEQN:178384 JACK FROM: Cust: R 761 JRef:1X6V7610023 T21 DrwNo:187.21.1744.14010 SSB /WHK 07/06/2021 4"14 3' 3' 6"3 1'9"38'1" 9'6"11 A B C 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 138 /-/-/103 /45 /74 C 42 /-/-/23 /-/- B 76 /-/-/50 /89 /- Wind reactions based on MWFRS A Brg Width = 3.5 Min Req =1.5 C Brg Width = 1.5 Min Req =- B Brg Width = 1.5 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 B - - HORZ(TL):0.002 B - - Creep Factor: 2.0 Max TC CSI:0.115 Max BC CSI:0.067 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C2AC Ply: 1 Qty:1 SEQN:178384 JACK FROM: Cust: R 761 JRef:1X6V7610023 T21 DrwNo:187.21.1744.14010 SSB /WHK 07/06/2021 4"14 3' 3' 6"3 1'9"38'1" 9'6"11 A B C 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 E 18 /-/-/13 /13 /- D 77 /-/-/55 /62 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.004 F 999 360 VERT(CL):0.005 G 999 240 HORZ(LL):-0.003 C - - HORZ(TL):0.003 C - - Creep Factor: 2.0 Max TC CSI:0.094 Max BC CSI:0.055 Max Web CSI:0.018 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C2T Ply: 1 Qty:1 SEQN:178372 JACK FROM: Cust: R 761 JRef:1X6V7610023 T22 DrwNo:187.21.1744.15207 SSB /WHK 07/06/2021 2'4"14 2'4"14 3' 7"2 2'8"6 2'8"6 3' 3"101' 6"3 8"1'1"31'9"31'11"138'1" 8'9" 9'6"11 A B C D EFGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 E 18 /-/-/13 /13 /- D 77 /-/-/55 /62 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.004 F 999 360 VERT(CL):0.005 G 999 240 HORZ(LL):-0.003 C - - HORZ(TL):0.003 C - - Creep Factor: 2.0 Max TC CSI:0.094 Max BC CSI:0.055 Max Web CSI:0.018 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C2T Ply: 1 Qty:1 SEQN:178372 JACK FROM: Cust: R 761 JRef:1X6V7610023 T22 DrwNo:187.21.1744.15207 SSB /WHK 07/06/2021 2'4"14 2'4"14 3' 7"2 2'8"6 2'8"6 3' 3"101' 6"3 8"1'1"31'9"31'11"138'1" 8'9" 9'6"11 A B C D EFGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 D 92 /-/-/50 /-/- C 122 /-/-/79 /137 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.006 D - - HORZ(TL):0.007 D - - Creep Factor: 2.0 Max TC CSI:0.325 Max BC CSI:0.252 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C3 Ply: 1 Qty:2 SEQN:178351 JACK FROM: Cust: R 761 JRef:1X6V7610023 T13 DrwNo:187.21.1744.16323 SSB /WHK 07/06/2021 5' 5'1' 6"3 2'7"32'9"138'1" 10'4"11 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 D 92 /-/-/50 /-/- C 122 /-/-/79 /137 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.006 D - - HORZ(TL):0.007 D - - Creep Factor: 2.0 Max TC CSI:0.325 Max BC CSI:0.252 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C3 Ply: 1 Qty:2 SEQN:178351 JACK FROM: Cust: R 761 JRef:1X6V7610023 T13 DrwNo:187.21.1744.16323 SSB /WHK 07/06/2021 5' 5'1' 6"3 2'7"32'9"138'1" 10'4"11 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 211 /-/-/150 /79 /125 C 83 /-/-/41 /-/- B 126 /-/-/83 /144 /- Wind reactions based on MWFRS A Brg Width = 3.5 Min Req =1.5 C Brg Width = 1.5 Min Req =- B Brg Width = 1.5 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.003 B - - HORZ(TL):0.008 B - - Creep Factor: 2.0 Max TC CSI:0.347 Max BC CSI:0.200 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C3AC Ply: 1 Qty:1 SEQN:178387 JACK FROM: Cust: R 761 JRef:1X6V7610023 T17 DrwNo:187.21.1744.17383 SSB /WHK 07/06/2021 4"14 5' 5' 6"3 2'7"38'1" 10'4"11 A B C 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Left cantilever is exposed to wind Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL A 211 /-/-/150 /79 /125 C 83 /-/-/41 /-/- B 126 /-/-/83 /144 /- Wind reactions based on MWFRS A Brg Width = 3.5 Min Req =1.5 C Brg Width = 1.5 Min Req =- B Brg Width = 1.5 Min Req =- Bearing A is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):0.003 B - - HORZ(TL):0.008 B - - Creep Factor: 2.0 Max TC CSI:0.347 Max BC CSI:0.200 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C3AC Ply: 1 Qty:1 SEQN:178387 JACK FROM: Cust: R 761 JRef:1X6V7610023 T17 DrwNo:187.21.1744.17383 SSB /WHK 07/06/2021 4"14 5' 5' 6"3 2'7"38'1" 10'4"11 A B C 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 E 59 /-/-/35 /3 /- D 137 /-/-/94 /129 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.070 F 835 360 VERT(CL):0.105 F 560 240 HORZ(LL):-0.033 C - - HORZ(TL):0.048 C - - Creep Factor: 2.0 Max TC CSI:0.324 Max BC CSI:0.100 Max Web CSI:0.067 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C3T Ply: 1 Qty:1 SEQN:178375 JACK FROM: Cust: R 761 JRef:1X6V7610023 T46 DrwNo:187.21.1744.18363 SSB /WHK 07/06/2021 2'4"14 2'4"14 5' 2'7"2 2'8"6 2'8"6 5' 2'3"101' 6"3 8"1'11"32'7"32'9"138'1" 8'9" 10'4"11 A B C D E FGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 E 59 /-/-/35 /3 /- D 137 /-/-/94 /129 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.070 F 835 360 VERT(CL):0.105 F 560 240 HORZ(LL):-0.033 C - - HORZ(TL):0.048 C - - Creep Factor: 2.0 Max TC CSI:0.324 Max BC CSI:0.100 Max Web CSI:0.067 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C3T Ply: 1 Qty:1 SEQN:178375 JACK FROM: Cust: R 761 JRef:1X6V7610023 T46 DrwNo:187.21.1744.18363 SSB /WHK 07/06/2021 2'4"14 2'4"14 5' 2'7"2 2'8"6 2'8"6 5' 2'3"101' 6"3 8"1'11"32'7"32'9"138'1" 8'9" 10'4"11 A B C D E FGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 143 /-/-/133 /90 /44 D 15 /-/-/9 /3 /- C -/-10 /-/29 /31 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.000 C - - HORZ(TL):0.000 C - - Creep Factor: 2.0 Max TC CSI:0.061 Max BC CSI:0.010 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C4 Ply: 1 Qty:6 SEQN:178352 JACK FROM: Cust: R 761 JRef:1X6V7610023 T12 DrwNo:187.21.1744.19337 SSB /WHK 07/06/2021 1' 1'1' 6"3 11"31'1"138'1" 8'8"11 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 143 /-/-/133 /90 /44 D 15 /-/-/9 /3 /- C -/-10 /-/29 /31 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.000 C - - HORZ(TL):0.000 C - - Creep Factor: 2.0 Max TC CSI:0.061 Max BC CSI:0.010 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C4 Ply: 1 Qty:6 SEQN:178352 JACK FROM: Cust: R 761 JRef:1X6V7610023 T12 DrwNo:187.21.1744.19337 SSB /WHK 07/06/2021 1' 1'1' 6"3 11"31'1"138'1" 8'8"11 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 D 54 /-/-/28 /-/- C 67 /-/-/41 /80 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 D - - HORZ(TL):0.001 D - - Creep Factor: 2.0 Max TC CSI:0.089 Max BC CSI:0.080 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C5 Ply: 1 Qty:5 SEQN:178353 JACK FROM: Cust: R 761 JRef:1X6V7610023 T11 DrwNo:187.21.1744.20540 SSB /WHK 07/06/2021 3' 3'1' 6"3 1'9"31'11"138'1" 9'6"11 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 D 54 /-/-/28 /-/- C 67 /-/-/41 /80 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.001 D - - HORZ(TL):0.001 D - - Creep Factor: 2.0 Max TC CSI:0.089 Max BC CSI:0.080 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C5 Ply: 1 Qty:5 SEQN:178353 JACK FROM: Cust: R 761 JRef:1X6V7610023 T11 DrwNo:187.21.1744.20540 SSB /WHK 07/06/2021 3' 3'1' 6"3 1'9"31'11"138'1" 9'6"11 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 E 18 /-/-/13 /13 /- D 77 /-/-/55 /62 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.004 F 999 360 VERT(CL):0.005 G 999 240 HORZ(LL):-0.003 C - - HORZ(TL):0.003 C - - Creep Factor: 2.0 Max TC CSI:0.094 Max BC CSI:0.055 Max Web CSI:0.018 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C5T Ply: 1 Qty:1 SEQN:178363 JACK FROM: Cust: R 761 JRef:1X6V7610023 T48 DrwNo:187.21.1744.21493 SSB /WHK 07/06/2021 2'4"14 2'4"14 3' 7"2 2'8"6 2'8"6 3' 3"101' 6"3 8"1'1"31'9"31'11"138'1" 8'9" 9'6"11 A B C D EFGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 189 /-/-/153 /94 /95 E 18 /-/-/13 /13 /- D 77 /-/-/55 /62 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.004 F 999 360 VERT(CL):0.005 G 999 240 HORZ(LL):-0.003 C - - HORZ(TL):0.003 C - - Creep Factor: 2.0 Max TC CSI:0.094 Max BC CSI:0.055 Max Web CSI:0.018 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C5T Ply: 1 Qty:1 SEQN:178363 JACK FROM: Cust: R 761 JRef:1X6V7610023 T48 DrwNo:187.21.1744.21493 SSB /WHK 07/06/2021 2'4"14 2'4"14 3' 7"2 2'8"6 2'8"6 3' 3"101' 6"3 8"1'1"31'9"31'11"138'1" 8'9" 9'6"11 A B C D EFGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 D 92 /-/-/50 /-/- C 122 /-/-/79 /137 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.006 D - - HORZ(TL):0.007 D - - Creep Factor: 2.0 Max TC CSI:0.325 Max BC CSI:0.252 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C6 Ply: 1 Qty:3 SEQN:178354 JACK FROM: Cust: R 761 JRef:1X6V7610023 T10 DrwNo:187.21.1744.22493 SSB /WHK 07/06/2021 5' 5'1' 6"3 2'7"32'9"138'1" 10'4"11 A B C D 5 12 3X4(B1) **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 D 92 /-/-/50 /-/- C 122 /-/-/79 /137 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 D Brg Width = 1.5 Min Req =- C Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):NA VERT(CL):NA HORZ(LL):-0.006 D - - HORZ(TL):0.007 D - - Creep Factor: 2.0 Max TC CSI:0.325 Max BC CSI:0.252 Max Web CSI:0.000 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C6 Ply: 1 Qty:3 SEQN:178354 JACK FROM: Cust: R 761 JRef:1X6V7610023 T10 DrwNo:187.21.1744.22493 SSB /WHK 07/06/2021 5' 5'1' 6"3 2'7"32'9"138'1" 10'4"11 A B C D 5 12 3X4(B1) 07/07/2021 COA #0 278 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 E 59 /-/-/35 /3 /- D 137 /-/-/94 /129 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.070 F 835 360 VERT(CL):0.105 F 560 240 HORZ(LL):-0.033 C - - HORZ(TL):0.048 C - - Creep Factor: 2.0 Max TC CSI:0.324 Max BC CSI:0.100 Max Web CSI:0.067 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C6T Ply: 1 Qty:1 SEQN:178366 JACK FROM: Cust: R 761 JRef:1X6V7610023 T49 DrwNo:187.21.1744.25120 SSB /WHK 07/06/2021 2'4"14 2'4"14 5' 2'7"2 2'8"6 2'8"6 5' 2'3"101' 6"3 8"1'11"32'7"32'9"138'1" 8'9" 10'4"11 A B C D E FGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 **WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAW ING! **IMPORTANT**FURNISH THIS DRAW ING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses. A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of thisdrawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org 6750 Forum Drive Suite 305 Orlando FL, 32821 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #2; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe-nails at top chord. Provide (2) 0.131"x3.0", min. toe-nails at bottom chord. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+/ R-/ Rh / Rw / U / RL B 259 /-/-/197 /124 /145 E 59 /-/-/35 /3 /- D 137 /-/-/94 /129 /- Wind reactions based on MWFRS B Brg Width = 7.6 Min Req =1.5 E Brg Width = 1.5 Min Req =- D Brg Width = 1.5 Min Req =- Bearing B is a rigid surface. Members not listed have forces less than 375# Loading Criteria (psf) TCLL:20.00 TCDL:7.00 BCLL:0.00 BCDL:10.00 Des Ld:37.00 NCBCLL:10.00 Soffit:2.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std:ASCE 7-16 Speed:170 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 4.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std:2014 Rep Fac: Yes FT/RT:20(0)/5(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL):-0.070 F 835 360 VERT(CL):0.105 F 560 240 HORZ(LL):-0.033 C - - HORZ(TL):0.048 C - - Creep Factor: 2.0 Max TC CSI:0.324 Max BC CSI:0.100 Max Web CSI:0.067 VIEW Ver: 20.02.01A.1209.10 Job Number:21-0598 /GROZA BUILDERS, INC. / /NEWTON RESIDENCE Truss Label:C6T Ply: 1 Qty:1 SEQN:178366 JACK FROM: Cust: R 761 JRef:1X6V7610023 T49 DrwNo:187.21.1744.25120 SSB /WHK 07/06/2021 2'4"14 2'4"14 5' 2'7"2 2'8"6 2'8"6 5' 2'3"101' 6"3 8"1'11"32'7"32'9"138'1" 8'9" 10'4"11 A B C D E FGH 5 12 3X4(B1) 3X3 1.5X4 1.5X4 07/07/2021 COA #0 278 514 Earth City Expressway Suite 242 Earth City, MO 63045 07/07/2021COA #0 278 514 Earth City Expressway Suite 242 Earth City, MO 63045 07/07/2021COA #0 278 514 Earth City Expressway Suite 242 Earth City, MO 63045 07/07/2021COA #0 278 514 Earth City Expressway Suite 242 Earth City, MO 63045 07/07/2021COA #0 278 514 Earth City Expressway Suite 242 Earth City, MO 63045 07/07/2021COA #0 278 514 Earth City Expressway Suite 242 Earth City, MO 63045 07/07/2021COA #0 278