HomeMy WebLinkAboutRidge Vent Product Approval(1)9/8/21, 11:57 AM
Florida Building Code Online
BCIS Home Log In User Registration
dUpr
4USER:
Approval
Ir USER: Public User
Ali
Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Anoroval Meru > Product or Application Search > ApplleaUun List > Application D•tall
FL #
FL38576-RI
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Accessories that are an Integral Part of the Roofing System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License
PE-62354
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
12/06/2026
Validated By
Lucas A. Turner, RE., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Standard
TAS 100A
Year
1995
Product Approval Method
Method 1 Option D
https:/lfloridabuildi ng.org/prlpr_app_dtl.aspx?param=wGEVXQwtDq urhYH%2fNuQVrH7xpTGbOI snR IH RyDs3yAXKxR5eytbrsg%3d%3d 1/2
9/8/21, 11:57 AM Florida Building Code Online
Date Submitted 06/15/2021
Date Validated 06/15/2021
Date Pending FBC Approval 06/18/2021
Date Approved 08/10/2021
Summary of Products
FL #
Modal, Number or Name
Description
38576.1
Dynamic Ridge Vent
0.032" Alum or 26 Ga Steel Vented Ridge Cap (Low Slope).
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL38576 RI 11 Rldoel Dwa2,=
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL38576 R3 AE Rid el Eval2.odf
Limits of Use.
I Created by Independent Third Party: Yes
38576.2
Dynamic Ridge Vent
0.032" Alum or 26 Ga Steel Vented Ridge Cap (High Slope)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL38576 Rl 11 Rldae2 Dwa2,pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL38576 R1 AE Ridae2 Eva12.odf
Limits of Use.
Created by Independent Third Party: Yes
Bach Nerd
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Flonda is an AA/EED employer i'gaydpht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, Contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1),
Florida Statutes, ef/active October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made avallable to Me public. To detem nine If you are a licensee under Chapter 455, ES., please click here .
product Approval Acupts:
TWI®®e
Credit Card
Safe
https://8oridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDqurhYH%2fNuQVrH7xpTGbQlsnRIHRyDs3yAXKxR5eytbrsga/o3d%3d 2/2
I 'WOLTERS ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
15211 97th Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225-1982
PRODUCT EVALUATION
(FOR HVHZ APPROVED PRODUCT)
PRODUCT: DYNAMIC VENTED RIDGE CAP (HIGH SLOPE)
(FLPA# 38576.2)
MANUFACTURER: DYNAMIC METALS, LLC
3201 SE DOMINICA TERRACE
STUART, FL 34997
To all concerned,
The Dynamic Vented Ridge Cap (High Slope) is manufactured by Dynamic Metals LLC from 0.032"
Fluropon coated aluminum (25 ksi min) or 26 Ga. galvalume or Fluropon coated steel (50 ksi min). The vented
ridge cap meets the requirements of Sections 1507.4 and 1518.9 of the 7th Edition (2020) Florida Building Code.
The panels have been tested per TAS 100(A) by Intertek B&C, with results shown in test report M1246.01-450-18.
It has also been tested per TAS 110 by PRI Construction Materials Technologies, with results shown in test reports
VLS-004-02-01 and VLS-005-02-01.
Technical Documentation:
1. Drawing "DMRVHS-HZ" dated 4/19121, signed and sealed by Scott Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test Reports listed above by PRI Construction Materials Technologies, signed and sealed by Zachary
R Priest, PE.
4. Supplemental Calculations to support DMRVHS-HZ, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 7th Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This system is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Ridge Cap Width: 121/2" (Length is unlimited)
Maximum Ridge Cap Height: Varies (Based on roof slope)
Min. Slope: 3112"
SPECIALIZING IN IMPACT k�5151ANf Cl1P1AINWPLI 5, StO FRONTS, & WNPOW5
Minimum Substrate: '/i (15/32" min) 5-ply CDX Plywood or'/:' solid wood planks (S.G. = .42
min) nailed to 2x rafters spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The %" wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architecl/Engineer
or
Structural panels with 16 Ga. (min) Steel Purlins.
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2
2. Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate is by others and is not a part of this evaluation.
4. All panel system perimeters, penetrations, and transitions to be
flashed and sealed per the requirements of RAS 133.
5. Rational analysis, provided by a Florida licensed Architect/Engineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities having jurisdiction.
If you have any questions or need more information concerning this approval please contact me.
Thank you,
GQ�I VVOL11#11j`F/"
Ole
No 62354
Scott Wolters
* '•
FL PE# 62354
: -o CIC c
JUN 14 2021
STATE OF 411
: o'. . 4Q
0RIOP:�2`:
%1n�tttt�'
SPECIALIZING IN IMPACT RE95TANT CU?rANWA15. 5f0MFV0NT5, & WINDOW5
_ __, m_w
) j _ , � m � _ ; �\
_ _ --
: -sc SIVA A >w»NAG
�.
|( $ §
,- - !
§! §a.
i
® -
!§ �a
Zz
< 0ƒ
I �-0 _
w ® §
-
■ � 2 _
_ . �x
I � �z & Z
\ ,
,§ !
§�
!; on
!! (
(\ \§
0 �}cr
o `
�
Lr) \�
� B.
« � ! ;,|
LLI
o < 3 6 z 64 )§
� m b M ) |_ §|
0 2 E|�§k§
LLI % k \
z zLLI w®®■|
LLJ >BkCL x <W,/
.���i
g —J o R §§22/
« � WHO
E F-,z
z n � � _ N �it
» qcl)»
0 ono