Loading...
HomeMy WebLinkAboutAPPROVED Shwinco Sliding Door Drawings 30505.3BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJASHWINCO ARCHITECTURAL PRODUCTS, LLC SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZ INSTALLATION ANCHORAGE DETAILS GENERAL NOTES: 1.THIS PRODUCT HAS BEEN TESTED, EVALUATED AND DESIGNED TO THE DESIGN PRESSURE(S) STATED HEREIN IN ACCORDANCE WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). THIS PRODUCT CAN BE USED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2.THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED UL TEST REPORT NO. SV31355-20190517-REPORT-B & SV31355-20190517-REPORT-C AND ASSOCIATED LABORATORY DRAWINGS BY NATIONAL CERTIFIED TESTING LABORATORIES. 2.1.PERFORMANCE STANDARDS USED IN TESTING FOR HVHZ LOCATIONS WERE TAS 201-94, TAS 202-94 AND TAS 203-94. 2.2.PERFORMANCE STANDARDS USED IN TESTING FOR NON-HVHZ LOCATIONS WERE AAMA/WDMA/CSA 101/I.S.2/A440-11, ASTM E1886-13a, AND ASTM E1996-14a. 3. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE / MASONRY AND 2X FRAMING FRAMING SUBSTRATES AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS THE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION. 4.1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS THE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION. 5.THE PRODUCT SHOWN HEREIN WAS TESTED WITH IMPACT PROTECTIVE GLAZING SHOWN IN DETAIL A AND B ON SHEET 11 FOR LARGE MISSILE IMPACT (SMALL MISSILE IMPACT ENVELOPED) IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ). WHEN INSTALLED IN LOCATIONS WHERE WINDBORNE DEBRIS PROTECTION REQUIREMENTS EXIST, THIS PRODUCT DOES NOT REQUIRE OPENING PROTECTION. 6.SITE CONDITIONS NOT COVERED IN THIS PRODUCT EVALUATION DOCUMENT ARE SUBJECT TO ADDITIONAL ENGINEERING ANALYSIS BY A LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 7.MATERIALS 7.1.FRAME MATERIAL: EXTRUDED RIGID PVC BY VISION EXTRUSIONS LIMITED APPROVED PER CURRENT MIAMI-DADE NOTICE OF ACCEPTANCE. 7.2.LAMINATED GLAZING INTERLAYER: EASTMAN CHEMICAL CO. SAFLEX PVB AND VANCEVA APPROVED PER CURRENT MIAMI-DADE NOTICE OF ACCEPTANCE. 7.3.GLASS MEETS THE REQUIREMENTS OF ASTM E1300-09a AND EXCEEDS THE DESIGN PRESSURES ON SHEETS 3 AND 4. 8.DESIGNATION "X" STANDS FOR OPERABLE PANEL AND '"O" STANDS FOR FIXED PANEL 9.INTERIOR AND EXTERIOR FINISHING AND PERIMETER SEALING ARE FOR ILLUSTRATIVE PURPOSES ONLY. THESE DRAWINGS CERTIFY THE DOOR INSTALLATION ONLY. WATER PROOFING OF THE INSTALLED DOOR IS NOT PART OF THIS INSTALLATION CERTIFICATION. WATER PROOFING SHALL BE THE RESPONSIBILITY OF THE INSTALLER. 9.1.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH THE FBC RESIDENTIAL AND BUILDING AND WITH FMA/AAMA/WDMA PROTOCOLS. 9.2.SEE INSTALLATION NOTE 2.2 ON SHEET 4 FOR STRUCTURAL ADHESIVE REQUIREMENTS FOR 2-TRACK SILL INSTALLATION. 10.SEE SHEETS 3 AND 4, GENERAL NOTES FOR APPROVED CONFIGURATIONS. 11.SEE SHEETS 3 AND 4 FOR DESIGN PRESSURE BASED ON GLAZING REQUIREMENTS AND ASSOCIATED ANCHOR REQUIREMENTS. INSTALLATION NOTES: 1.PRODUCT ANCHORS SHALL BE AS DESIGNATED AND LOCATED AS SHOWN IN THIS PRODUCT EVALUATION DOCUMENT. ANCHOR EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER AND SIDING. 2.SEE INSTALLATION ANCHOR SCHEDULE ON SHEET 2 FOR TYPE AND GRADE OF ANCHOR, AND/OR MANUFACTURER'S ANCHOR SPECIFICATIONS, INCLUDING MINIMUM NOMINAL SIZE, MINIMUM EMBEDMENT INTO SUBSTRATE AND MINIMUM EDGE DISTANCES. 2.1.EDGE DISTANCES SHALL BE MEASURED FROM CENTERLINE OF ANCHOR TO EDGE OF STRUCTURAL SUBSTRATE EITHER TO THE INTERIOR OR EXTERIOR OF THE FENESTRATION PRODUCT. 2.2.MINIMUM EMBEDMENT SHALL BE BASED ON PENETRATION INTO MAIN WIND FORCE RESISTING SYSTEM SUBSTRATE. 2.3.ALL INSTALLATION ANCHORS SHALL BE MADE OF A CORROSION RESISTANT MATERIAL OR HAVE A CORRISION RESISTANT COATING. 3.WOOD BUCKS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN THE CURRENT EDITION OF THE FLORIDA BUILDING CODE. 4.DISSIMILAR MATERIALS INCLUDING FASTENERS THAT MAY COME INTO CONTACT SHALL HAVE BEEN PROTECTED AS DEFINED IN THE CURRENT EDITION OF THE FLORIDA BUILDING CODE. 5.INSTALLATION DETAILS 5.1.SEE SHEETS 3 AND 4 FOR ELEVATION DETAILS. 5.2.SEE SHEETS 5 THROUGH 8 FOR SECTION VIEWS OF SPECIFIC ANCHOR INSTALLATION DETAILS. 5.3.SEE SHEET 9 FOR GLAZING DETAILS. 6.TWO (2) INSTALLATION ANCHORS ARE REQUIRED AT EACH ANCHOR LOCATION SHOWN IN ELEVATION DETAILS (SHEETS 3 AND 4) AT 2-TRACK, 3-TRACK AND 4-TRACK HEAD, SILL AND JAMB EXTRUSIONS. 6.1.EXCEPTION FOR 2-TRACK XX AND XO CONFIGURATION. 1/4" FILLET PERIMETER BEAD OF STRUCTURAL ADHESIVE SHALL BE USED IN LIEU OF INSTALLATION ANCHORS AT THE SILL. SEE SHEET 4 FOR MORE DETAILS. BOTTOM OF SILL SHALL BE SEALED TO SUBSTRATE USING STRUCTURAL SILICONE ADHESIVE. 7.ANCHOR QUANTITIES AND SPACING / EMBEDMENT AND EDGE DISTANCE 7.1.THE NUMBER OF INSTALLATION ANCHORS IS BASED ON THE MAXIMUM END DISTANCE (ED) AND THE MAXIMUM ON CENTER (O.C.) SPACING PLACEMENT OF ANCHORS IN ACCORDANCE WITH ELEVATIONS ON SHEETS ON SHEETS 3 AND 4. 7.2.END DISTANCES AND O.C. SPACING LESS THAN THAT SHOWN IN THE ELEVATION ON SHEETS ON SHEETS 3 AND 4 ARE ACCEPTABLE. 7.3.FOR DOOR SIZES SMALLER THAN THOSE SHOWN, ANCHOR QUANTITIES CAN BE REDUCED WHILE MAINTAINING EDGE DISTANCE AND O.C. SPACING REQUIREMENTS. 7.4.ANCHOR QUANTITIES AND SPACING SHOWN ARE BASED ON THE LOWER OF ANCHOR SPACING USED IN TESTING OR REQUIRED BY LOADING AT DESIGN PRESSURE. 7.5.SEE EMBEDMENT AND EDGE DISTANCE DESCRIPTION ON SHEET 2. 8.MAXIMUM ALLOWABLE SHIM THICKNESS IS 1/4 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF WOOD COMPOSITE, HIGH DENSITY PLASTIC OR SIMILAR LOAD BEARING MATERIAL. 9.FOR CONCRETE BLOCK APPLICATIONS DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. 10.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED IN THE INSTALLATION ANCHOR SCHEDULE ON SHEET 2. TABLE OF CONTENTS SHEET SHEET DESCRIPTION 1 GENERAL NOTES, INSTALLATION NOTES, TABLE OF CONTENTS 2 ANCHOR SCHEDULE - EMBEDMENT & EDGE DISTANCE - ANCHOR INSTALL 3 4-TRACK XXXX & XXXO DOOR ELEVATION - ANCHOR LAYOUT 4 2-TRACK XX & XO DOOR ELEVATION - ANCHOR LAYOUT 5 2, 3 AND 4-TRACK VERTICAL SECTIONS 5A 2-TRACK ELEVATION & VERTICAL SECTION - SILL INSTALLATION CLIP OPTION 6 4-TRACK XXXX & XXXO HORIZONTAL CROSS SECTIONS 7 3-TRACK XXX & XXO HORIZONTAL CROSS SECTIONS 8 2-TRACK XX & XO HORIZONTAL CROSS SECTIONS 9 GLAZING DETAILS 10 & 11 BILL OR MATERIALS GENERAL NOTES, INSTALLATION NOTES & TABLE OF CONTENTS1 BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJAFRAME ANCHORAGE MINIMUM EMBEDMENT AND EDGE DISTANCE THROUGH-FRAME INSTALLATION APPLICABLE TO HEAD, SILL (SHOWN) AND JAMBS (SHOWN) WOOD AND CONCRETE SCREW FRAME ANCHORAGE REQUIREMENTS (NOTE 5 FROM ANCHOR SCHEDULE TABLE ABOVE) THROUGH-FRAME INSTALLATION APPLICABLE TO HEAD, SILL (SHOWN) AND JAMBS – – – – ANCHOR SCHEDULE - EMBEDMENT & EDGE DISTANCE - ANCHOR INSTALL2 SERIES 9700 SLIDING GLASS DOOR - XXXX AND XXXO 4-TRACK SYSTEM (SHOWN) SIMILAR ARRANGEMENT FOR 3 TRACK CONFIGURATIONS LISTED BELOW EXTERIOR ELEVATION B* 6 A 5 INSTALLATION NOTES: 1.ANCHOR SPACING LOCATION TOLERANCES 1.1.ON CENTER (O.C.) SPACING ANCHOR LOCATION TOLERANCE IS +/- 1". 1.2.EDGE ANCHORS ARE 3" MAXIMUM AS SHOWN. 1.3.CONCRETE ANCHORS SHALL NOT BE SPACED LESS THAN 3" O.C. REGARDLESS OF STATED TOLERANCES. 2.ANCHOR QUANTITY AND SPACING 2.1.HEAD AND SILL 2.1.1.ANCHORS ARE QUANTITY EIGHTEEN (18) WITH MAXIMUM 11" ON CENTER (O.C.) SPACING. 2.1.2.EDGE ANCHORS ARE 3" MAXIMUM AS SHOWN. 2.1.3.ANCHOR QUANTITIES CAN BE REDUCED AS REQUIRED FOR SMALLER FRAMES AS LONG AS THE EDGE DISTANCE AND O.C. SPACING REQUIREMENTS ARE MET. 2.2.JAMBS 2.2.1.ANCHORS ARE QUANTITY TEN (10) WITH MAXIMUM 11" ON CENTER (O.C.) SPACING. 2.2.2.EDGE ANCHORS ARE 3" MAXIMUM AS SHOWN. 2.2.3.ANCHOR QUANTITIES CAN BE REDUCED AS REQUIRED FOR SMALLER FRAMES AS LONG AS THE EDGE DISTANCE AND O.C. SPACING REQUIREMENTS ARE MET. GENERAL NOTES: 1.APPROVED DOOR CONFIGURATIONS INCLUDE THE FOLLOWING. 1.1.XXXO AND XXXX, 4-TRACK 1.1.1.ELEVATION SHOWN THIS SHEET. 1.1.2.SECTION VIEWS ON SHEETS 5 AND 6. 1.2.XXO AND XXX, 3-TRACK 1.2.1.ELEVATION SIMILAR TO 4-TRACK. 1.2.2.SECTION VIEWS ON SHEETS 5 AND 7. 2.ANY STILE CONFIGURATION SHOWN IN HORIZONTAL SECTION VIEWS ON SHEETS 6 AND 7 ARE ALLOWED. 3.MAXIMUM FRAME AND PANEL SIZES 3.1.MAXIMUM FRAME SIZE IS 192.25" X 95.5" 3.2.MAXIMUM PANEL SIZE IS 51.55" X 92.75" 3.3.MAXIMUM PANEL DAYLIGHT OPENING (DLO) IS 40.625" X 81.875" 4.XXXO AND XXO DOOR CONFIGURATIONS SHOWN WITH FIXED (O) PANEL AT RIGHT JAMB IN EXTERIOR TRACK. 4.1.ACCEPTABLE TO ORIENT PANELS AS OXXX AND OXX WITH FIXED PANEL AT LEFT JAMB IN INTERIOR TRACK. 4.2.ACCEPTABLE TO ORIENT FIXED PANEL (O) IN EXTERIOR OR INTERIOR TRACK. B* 7 * SECTION B/8, 4-TRACK 4-PANEL SECTION (ELEVATION SHOWN) SECTION B/9, 3-TRACK 3-PANEL SECTION SILL ANCHORAGE SAME AS HEADER Max. Frame Size: 192.25" x 95.5" Max. Panel Size: 51.5" x 92.75" Max. Daylight Opening Size: 40.63" x 81.88"BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJA4-TRACK XXXX & XXXO DOOR ELEVATION - ANCHOR LAYOUT3PERFORMANCE RATING CONFIGURATION (SEE GENERAL NOTE 11) TRACKS NOTES GLAZING DETAIL (SEE SHEET 2) DESIGN PRESSURE (PSF) IMPACT RATING XXXO XXXX 4 SHEET 3, GENERAL NOTES 1.1, 2 & 3 A +/-65 LARGE MISSILE (SMALL MISSILE ENVELOPED) XXXO XXXX 4 SHEET 3, GENERAL NOTES 1.1, 2 & 3 B +/-50 XXO XXX 3 SHEET 3, GENERAL NOTES 1.2, 2 & 3 A +/-65 XXO XXX 3 SHEET 3, GENERAL NOTES 1.2, 2 & 3 B +/-50 SERIES 9700 SLIDING GLASS DOOR - XX AND XO 2-TRACK SYSTEM (SHOWN) EXTERIOR ELEVATION B 8 A 5 INSTALLATION NOTES: 1.ANCHOR SPACING LOCATION TOLERANCES 1.1.ON CENTER (O.C.) SPACING ANCHOR LOCATION TOLERANCE IS +/- 1". 1.2.EDGE ANCHORS ARE 3" MAXIMUM AS SHOWN. 1.3.CONCRETE ANCHORS SHALL NOT BE SPACED LESS THAN 3" O.C. REGARDLESS OF STATED TOLERANCES. 2.ANCHOR QUANTITY AND SPACING 2.1.HEAD 2.1.1.ANCHORS ARE QUANTITY TEN (10) WITH MAXIMUM 11" ON CENTER (O.C.) SPACING. 2.1.2.EDGE ANCHORS ARE 3" MAXIMUM AS SHOWN. 2.1.3.ANCHOR QUANTITIES CAN BE REDUCED AS REQUIRED FOR SMALLER FRAMES AS LONG AS THE EDGE DISTANCE AND O.C. SPACING REQUIREMENTS ARE MET. 2.2.SILL 2.2.1.SILL SHALL BE SEALED TO SUPPORTING SUBSTRATE OR BUCKING USING A 1/4" FILLET PERIMETER BEAD OF STRUCTURAL SILICONE ADHESIVE AT THE INTERIOR AND EXTERIOR. BOTTOM OF SILL SHALL BE SEALED TO SUBSTRATE USING STRUCTURAL SILICONE ADHESIVE. 2.2.2.APPROVED ADHESIVES INCLUDE THE FOLLOWING: 2.2.2.1.DOW CORNING 995 2.2.2.2.DOW CORNING DOWSIL 795 2.2.2.3.SIKA SIKASILGP & SIKASIL WS-305CN 2.2.2.4.OTHER STRUCTURAL SILICONE ADHESIVES MEETING SITE INSTALLATION REQUIREMENTS ALSO ACCEPTABLE PER ENGINEER OR ARCHITECT OF RECORD. 2.2.3.INSTALLATION CLIP 2.2.3.1.AN OPTIONAL INSTALLATION CLIP MAY BE EMPLOYED AT THE SILL. 2.2.3.2.THIS CLIP IS NOT REQUIRED AND ITS USE IS AT THE DISCRETION OF THE CONTRACTOR/INSTALLER. 2.2.3.3.SEE SHEET 5A FOR INSTALLATION DETAILS FOR CLIP. 2.3.JAMBS 2.3.1.ANCHORS ARE QUANTITY TEN (10) WITH MAXIMUM 11" ON CENTER (O.C.) SPACING. 2.3.2.EDGE ANCHORS ARE 3" MAXIMUM AS SHOWN. 2.3.3.ANCHOR QUANTITIES CAN BE REDUCED AS REQUIRED FOR SMALLER FRAMES AS LONG AS THE EDGE DISTANCE AND O.C. SPACING REQUIREMENTS ARE MET. GENERAL NOTES: 1.APPROVED DOOR CONFIGURATIONS INCLUDE THE FOLLOWING. 1.1.XO AND XX, 2-TRACK 1.1.1.ELEVATION SHOWN THIS SHEET. 1.1.2.SECTION VIEWS ON SHEETS 5 AND 8. 2.ANY STILE CONFIGURATION SHOWN IN HORIZONTAL SECTION VIEW ON SHEET 8 ARE ALLOWED. 3.MAXIMUM FRAME AND PANEL SIZES 3.1.MAXIMUM FRAME SIZE IS 99.85" X 95.5" 3.2.MAXIMUM PANEL SIZE IS 51.55" X 92.75" 3.3.MAXIMUM PANEL DAYLIGHT OPENING (DLO) IS 40.625" X 81.875" 4.XO DOOR CONFIGURATION SHOWN WITH FIXED (O) PANEL AT RIGHT JAMB IN EXTERIOR TRACK. 4.1.ACCEPTABLE TO ORIENT PANELS AS OX WITH FIXED PANEL AT LEFT JAMB IN INTERIOR TRACK. 4.2.ACCEPTABLE TO ORIENT FIXED PANEL (O) IN EXTERIOR OR INTERIOR TRACK. Max. Frame Size: 99.85" x 95.5" Max. Panel Size: 51.5" x 92.75" Max. Daylight Opening Size: 40.63" x 81.88"BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJA2-TRACK XX & XO DOOR ELEVATION - ANCHOR LAYOUT4PERFORMANCE RATING CONFIGURATION (SEE GENERAL NOTE 11) TRACKS NOTES GLAZING DETAIL (SEE SHEET 2) DESIGN PRESSURE (PSF) IMPACT RATING XO XX 2 SHEET 3, GENERAL NOTES 1.3, 2 & 3 A +/-65 LARGE MISSILE (SMALL MISSILE ENVELOPED)XO XX 2 SHEET 3, GENERAL NOTES 1.3, 2 & 3 B +/-50 SERIES 9700 SLIDING GLASS DOOR APPLICABLE TO 2-TRACK, 3-TRACK AND 4-TRACK DOOR CONFIGURATIONS. VERTICAL CROSS SECTIONS A 5 INTERIOREXTERIOR EXTERIOR EXTERIORINTERIOR INTERIOR SEE NOTE 1 BELOW. SEE NOTE 1 BELOW. SEE NOTE 1 BELOW. SEE NOTE1 BELOW. SEE NOTE 1 BELOW. SEE NOTE 1 BELOW. FRAME WIDTH 5.90"FRAME WIDTH 8.28"FRAME WIDTH 10.66" FRAME WIDTH FOR 2-TRACK, 3-TRACK AND 4-TRACK SILL SHOWN. APPLICABLE TO HEAD AND JAMBS BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJA2, 3, 4-TRACK VERTICAL SECTIONS5 SERIES 9700 SLIDING GLASS DOOR - XX AND XO 2-TRACK SYSTEM (SHOWN) OPTIONAL SILL INSTALLATION CLIP EXTERIOR ELEVATION B 8 A 5A Max. Frame Size: 99.85" x 95.5" Max. Panel Size: 51.5" x 92.75" Max. Daylight Opening Size: 40.63" x 81.88" INTERIOR EXTERIOR SEE NOTE 1 BELOW. SEE NOTE1 BELOW. SERIES 9700 SLIDING GLASS DOOR APPLICABLE TO 2-TRACK WITH OPTIONAL SILL INSTALLATION CLIP VERTICAL CROSS SECTIONS A 5A OPTIONAL INSTALLATION CLIP. SEE SHEET 4, NOTE 2.2.3.BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJA2-TRACK ELEVATION & VERTICAL SECTION - SILL INSTALLATION CLIP OPTION5A BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJASERIES 9700 SLIDING GLASS DOOR APPLICABLE 4-TRACK XXXX & XXXO DOOR CONFIGURATION HORIZONTAL CROSS SECTIONS B 6 SEE NOTE 1 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. INTERIOR EXTERIOR 4-TRACK, XXXX & XXXO - HORIZONTAL CROSS SECTION6 BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJASEE NOTE 1 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. SERIES 9700 SLIDING GLASS DOOR APPLICABLE 3-TRACK XXX & XXO DOOR CONFIGURATION HORIZONTAL CROSS SECTIONS B 7 INTERIOR EXTERIOR 3-TRACK, XXX & XXO - HORIZONTAL CROSS SECTION7 BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJASERIES 9700 SLIDING GLASS DOOR APPLICABLE 2-TRACK XX & XO DOOR CONFIGURATION HORIZONTAL CROSS SECTIONS B 8 SEE NOTE 1 BELOW. SEE NOTE 2 BELOW. SEE NOTE 2 BELOW. EXTERIOR INTERIOR 2-TRACK, XX & XO - HORIZONTAL CROSS SECTION8 BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJAGLAZING DETAIL A LAMINATED IGU INTERIOR GLAZED WITH DOW 995 BACK-BEDDING EXTERIOR INTERIOR GLAZING DETAIL B LAMINATED IGU INTERIOR GLAZED WITH DOW 995 BACK-BEDDING EXTERIOR INTERIOR GLAZING DETAIL9 BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJABILL OF MATERIALS10 BYDATE12OF8/2/19DESCRIPTIONREVTITLE:DRAWN BY:SCALE:REV:DATE:DRAWING NO:SHEET:Robert J. Amoruso, P.E. Florida P.E. No. 49752 PTC PRODUCT DESIGN GROUP, LLCPO BXO 520775LONGWOOD, FLORIDA 32752FBPE C.A. NO. 25935Phone: 321.690.1788Fax: 321.690.1789Email: info@ptc-corp.comRJASHW0004SHWINCO ARCHITECTURAL PRODUCTS, LLC171 JET SERVICES WAYDOTHAN, AL 36303SERIES 9700 VINYL SLIDING GLASS DOOR - HVHZBNONEPROJECT # 421-0602AUPDATE TO THE CURRENTEDITION FBC9/3/20RJABADD OPTIONAL INSTALLATIONCLIP TO 2-TRACK SILL7/7/21RJABILL OF MATERIALS11