HomeMy WebLinkAboutWindowDoor Replacement1
James Philip Drago, Registered Architect
333 NE 24th St, Boca Raton, Florida 33431......... Seal # AR009780
(561) 361-7161 office (954) 275-8834 cell (561) 361-8096 fax
"WINDOW / DOOR REPLACEMENT LETTER"
Date: September 9, 2021
Project: Kos Door/Window Replacement
Address: 9650 S Ocean Drive, #404, Jensen Beach, FL 34957
Dear: St Lucie County Building Official(s),
I (James Drago, Registered Architect) have conducted a review of the proposed
design pressures (PSF) for the above Commercial Property location to replace the
doors and windows shown on the attached Floor Plan.
Above 30' component height are as follows:
(See attached Floor Plan for specific door and window size and design pressures)
• ZONE 4 — 53.7 / -67.5
• ZONE 5 — 53.7 -12..6
• Zone 5 is defined as 6.4' of building wall from building corners.
• Zone 4 is defined as all other wall space.
Design pressures calculated with
• II occupancy category
• 16o mph ultimate design wind speed
• D asce exposure category
• 1 wind directionally factor (Kd)
• 1 topographical factor (Kzt)
• 64' _ min. (least) building dimension
• 18o' mean roof height, mrh
• _36' elevation of installation
• Flat (<io deg) roof slope
Therefore, please accept this letter as a formal certification that to the best of my
belief and professional judgment that the proposed design pressures (PSF) to
replace the doors and windows -installation will meet (or exceed) the minimum
requirements set: fol y he3262a-Florida Building Code — Building, 7th Edition.
,� car — ,��e s �- ,: ; •: �;
Thank yo,IUMt L Ice in this matter.
.tom{}wo�Q"'�Cii6�k' - -+:. � � - x�`•�_ .
James Philip Drago,, Reg End Architect AR #00978o