HomeMy WebLinkAboutSurvey for Permitting S V q'2O'13R" R 1 LEGEND OF SURVEY ABBREVIATIONS
r[RAGOINTROL
WALL W 16 O.O O' V.V J A DELTA ANGLE N.V. HEAD HWALL
WALL A/C AIR CONDITIONER L. LENGTH
o. 'N. o.7TI. SET GAP AVE AVENUE a LIGHT ALL
POLE
AVG. AVERAGE M, MEASURED
T GAP @.B, HEARING BASE MA, MANHOLE
E
C/L WALE . K. BASELINE M.H.V.L.MEAN HIGH WATER LINE
H.M. BENCH MARK NONL NR%BENT
HS L. BUILDING ING SETBACK LINE CK NLD NAIL L DISK
5' WALL MAINTENANCE ESMT. _I N. NORTH
BLVD, BOULEVARD
C. CURVE No, NUMBER
N.IC. NOT INCLUDED
b ` C.B. CHORD BEARING O.H.V. OVERHEND VIRES
O O CHS. CONCRETE BLOCK . PAGE0 VALVE 0. CHORDTDISTANCE PP.K. PARKER. PLAT
P.C. POINT OF ACURVATURE
UCH NAIL
T 6ULONG SETBACK C.LF. CHAIN LINK FENCE P.C.P. PERMANENT CONTROL POINT
VALVE F� IGA' 400 O C.D. CHORD CENTERDISTANCE
I W C.N, CONCRETE MONUMENT P.I. POINT T INTERSECTION
37.6' C.N.P. CORRUGATED METAL PIPE PL' PROPERTY LINE
CONC. CONCRETE PN. POWER METER
C.R. COUNTY ROAD P.G.B. POINT OF BEGINNING
CT. COURT P,O,C. PCINT OF COMMENCEMENT
C/S CONCRETE SLAB PRC POINT OF REVERSE CURVE
CDR. CORNER P.R.M. PERMANENT REFERENCE MONUMENT
D. DEED PROP. PROPOSED
D.B. DEED BOOK RA� RADIAL O POWER R RADIUS
d R' DEP DEPARTMENT OF R/V RIGHT OF WAY
L ENVIRONMENTAL PROTECTION S. SOUTH
DIST. DPARTMISTANC SEC. SECTION
LOT 15 OR DEPARTMENT OF SOFT. SQUARE FEET
�..{_ NATURAL RESOURCES S.R. STATE ROAD
VACANT V ER EAST DRIVE ST. STREET
YS 1.OT 1.8 ESMT. EASEMENT ST& STRUCTURE
N P� ELEC. ELECTRICAL STA STATION
VACANT EL. ELEVATION SUB. SUBDIVISION
N E.O.V. EDGE OF WATER T.ILK TEMPORARY BENCH MARK
F.F. FINISHED FLOOR TELE. TELEPHONE
4G.O' O V FIRE HYDRANT TOPO. TOPOGRAPHA CAL w
p F. IRON P.L. FLORIDA POWER L LIGHT TR. ACT TR
m I.P. IRON PIPE TW TRACT P
• ♦ O LR IRON ROD U L 0 UTILITY L DRAINAGE
IRV. INVERT W. UNREADABLE
IRR. GOVIRRIERNMEATIONT
W. WEST
CIO20.0_ G'O GNO.T GROUND MENT COMBINED LOWATER TS
GR. GRADE WV WATER VALVE
LOT lq FORM BOARD LOCATION LOT 18 HIP. HIGH CFORMS ONLY
L INT
#15q
TOP OF FORMS GOBOXSi ® TELE.
EL.=7.0' I , &JBOX
N
9 LEGAL DE50RIPTIONI ALL OF LOT 18+19. BLOCK 2
AVALON BEACH P.U.D.
O G.7' ACCORDING TO THE PLAT THEREOF AS RECORDED
O IN PLAT BOOK 55. PAGE 1q OF THE PUBLIC
9 a 39.5' 10' BUILDING SETBACK RECORDS OF ST. LUCIE CO.. FLORIDA. SAID LANDS
47.6' c 40.0' LYING IN ST. LUCIE CO.. FLORIDA.
TELE' CONTAINING 0.12 ACRES MORE OR LE55
' eo% .G' PLASTIC 10' UTILITY E5MT. °
/ VERTICAL PIPE of SURVEY NOTES:
C BELIEVED TO BE C/L ) 1. LANDS SHOWN HEREON WERE NOT ABSTRACTED
FOR RIGHTS-OF-WAY AND/OR EASEMENTS OF
Q (� RECORD.
Y 5ET N D N(J-IO2O'13"E 115.44' SET GAP NA ED INDI DUALS 2. THIS SRVEY IS CERTIFIED ONLY TO THE BELOW
a' cone. 3. LEGAL DESCRIPTION SUPPLIED BY CLIENT.
WALK 4. SQ. FT. OF HOUSE (IF SHOWN) SUPPLIED BY
CLIENT.
5. NO STRUCTURES OR UTILITIES THAT ARE
BENEATH THE SURFACE HAVE BEEN LOCATED.
bi 6. ALL SET CAPS LABELED KMA ENG & SURVEY L.B.
B
GOMGASi OCEAN ESTATES DRIVE I 8351 ARE SUPPORTED WITH AN 78- LONG #5 REBAR.
SET T.B.M ON Prc+TAB C 30' PRIVATE R/W D FK+TAB ALL SET NAIL & DISKS ARE MAG NAILS AND STAINLESS
C497U C4971)
EC4g7I
20' PAVEMENT eL-4.72' ALLEFOU STAMPED
ABSj851ROD WITH A CAP
FIBER OPTIC S AS LABELED ON SURVEY.
GABLE
ALL FOUND REBAR ARE A 5/8' ROD UNLESS
V / OTHERWISE NOTED.
CATCH SET N+D 7. ALL LOT DIMENSIONS ARE PLAT AND MEASURED
DA5IN
EL.-3.G4' UNLESS OTHERWISE NOTED.
8. BEARING BASE ON SOUTH LINE OF LOT 18&19
9. ORIGINAL SL BM:K-633 EL.-17.74' NAVD 88
10. ELEVATIONS (IF SHOWN) HEREON ARE BASED
S CNIM9k aA1;+'XM58), TtGESS OTHERWISE NOTED.
VB CUSTOMS HOMES
PK+TAB
C4971)
EL.-4.17' /
L=47.42'
CATCH
Go•F 1 L0"1' 15 R=G2.00'
ELr3.e2' O\0 \1 VACANT
e w toJ ¢ A=43°4q'12'
GB=NG7°25'37'E
GD=4G.27'
I- COUNTY WATER + SEWER AVAILABLE FOR THIS TE PLAN NOTES- 2a�1• 2' GUTTER
PARCEL. PK+TAB 2• GUTTER '
2, A DRIVEWAY MAX" SLOPE IS NOT TO EXCEED A ` C4971)
SO7. GRADE EL.-4.92'
3. FIRST FLOOR ELEVATION ESTABLISHED WITHOUT A l"
HEALTH DEPARTMENT PERMIT. J
4: PROPOSED DRAINAGE PLAN DESIGNED TO MEET
FLORIDA BUILDING CODE. RESIDENTIAL
REQUIREMENT5.(R401.3)
5. ALL SLOPES AROUND THE PROPOSED STRUCTURE THIS SURVEY MAP AND REPORT OR COPIES THEREOF ARE SURVEY TYPE: FLOOD ZONE:X
ARE NOT TO EXCEED THE MAXIMUM ALLOWABLE SLOPE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED BOUNDARY S EFFECTIVE DATE: 02/19/20
GRADE OF 4-1 SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 1: ��/� ,Q� 7+ BOUNDARY/SITE DATE: REVISIONS: BY: PNL NO.: 12111CO087 K
BE SETN A CULVERT 15 BY PUBLIC WORKS UIRED THEDEPARTMENT EPART ENT AND W LERTS RBE 0 - - KMA Engineering <71C• SU1 ve ing, LLC CHECKED BY: W.E.H.1J� EH 7/30/21 CLIENT REQUESTS W.E.H ® INDICATES PROPOSED ELEVATION
ON
DETERMINED AT STAKE AND GRADE. DRAWN BY: J.P.L. 9/2/21 RAISE F.F.E. TO 7.0 W.E.H INDICATES AS-BUILT ELEVATION
T ALL STORMWATER RUNOFF IS NOT TO IMPACT THE ELEVATIONS ARE FOR cALC.
ADJACENT PROPERTIES AND MUST MEET A MINIMUM OF 17. Consulting Engineers & Surve ors FIELD BOOK: 396 10/28/21 FORM BOARD LOC. J.E.K. PURPOSES
SARE NOYWELLS OR SEPTICS
LONGITUDINAL SLOPE OR OTHERWISE ACCEPTED. 2345 14tb Ave. Suite 3 Vero Beach,Fl. 32960 PAGE NO. 2O SHOWN.- WITHIN 100' OF PROPERTY UNLESS
Be PLOT PLANS ARE NOT TO BE USED x,.o�- PROPOSED CONTOUR LINE
FOR CONSTRUCTION LAYOUT PURPOSES KMAPhone: (772) 569-6680 Fax: (772) 770-3446 E-Mail: survey@kmafl.com FIELD DATE-' 07 15 21 _ PROPOSED SCALE LINE
WITHOUT APPROVED BUILDING PERMITS. Lo/as/.L INDICATES LOT DRAINAGE
WILLIAM E. HA VR8T DAMID SCALE: 1"=101 ®INDICATES DRAINFIELD
AHLO/'.l.20NwL LAND ■ OA 4 LBAPP.IL ENGINEERING&SURVEYING Certificate of Authorization Number: L.B.8351 LIVING AREA 3000 so•Ft•
szoxaxxaw nxaoxernwa'BON No uaa JOB NO: 21-2470 LOT AREA 11TANK sa.Ft.
(�=SEPTIC TANK