Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Load Short Form 7/12/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hood Residence, Groza Builders, IncFor: TBD Pinetree Dr, Fort Pierce, FL 34982 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C** AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.6 Sensible cooling Btuh24220 Heating output Btuh26063 Latent cooling Btuh10380 Temperature rise °F21 Total cooling Btuh34600 Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.047 Air flow factor cfm/Btuh0.052 Static pressure in H2O0.85 Static pressure in H2O0.85 Space thermostat Load sensible heat ratio 0.75 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Foyer 75 1490 597 71 31 Master Suite 263 3863 2797 183 145 M Hall 20 0 0 0 0 Master Bath 113 1030 567 49 29 Linen 11 0 0 0 0 WIC 85 1868 676 88 35 Pantry 23 0 0 0 0 Laundry 64 2086 1379 99 71 Kit/DR/GR 703 6123 10439 290 540 Bath 61 586 282 28 15 Hall 54 0 0 0 0 Bed 2 142 1557 1564 74 81 Bed 3 143 1502 1558 71 81 WIC2 36 1126 380 53 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W WIC3 30 489 189 23 10 Bed 4 160 2639 1859 125 96 House 1980 24358 22287 1153 1153 Other equip loads 1826 970 Equip. @ 0.95 RSM 22187 Latent cooling 7558 TOTALS 1980 26185 29745 1153 1153 2021-Jul-12 09:41:12 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Building Analysis 7/12/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hood Residence, Groza Builders, IncFor: TBD Pinetree Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 18.047232.6Walls 4.511888.7Glazing 0.3893.7Doors 7.519551.0Ceilings 25.366233.33.3Floors 13.334882.2Infiltration 24.06292Ducts 00Piping 00Humidification 7.01826Ventilation0Adjustments 100.026185Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 12.428791.6Walls 11.2261019.0Glazing 0.4893.7Doors 12.428851.5Ceilings 000Floors 4.29750.6Infiltration 30.37048Ducts 4.2970Ventilation 24.95800Internal gains 00Blower 0Adjustments 100.023257Total Latent Cooling Load = 7558 Btuh Overall U-value = 0.085 Btuh/ft²-°F Data entries checked. 2021-Jul-12 09:41:12 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Component Constructions 7/12/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hood Residence, Groza Builders, IncFor: TBD Pinetree Dr, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Block R-9 Wall: Blk wall, Stuc Ext, 8" thk, R-9 Foam Fill, 1/2" Gyp Bd 3492.589.00.089135ne 2231.65 7361.6511512.589.00.089447se 5861.659172.589.00.089356sw 441.65692.589.00.08927w 7961.6512452.589.00.089483nw 23861.6537302.589.00.0891448all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 4931.469942.9411.00.101338 Windows Non-Impact: Non-Impact; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 40717.61958.4100.29023ne 27216.81368.4100.29016se 27216.81368.4100.29016sw 28417.61368.4100.29016nw 123717.26038.4100.29072all Non-Impact: Non-Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 38216.52028.7000.30023se Non-Impact: Non-Impact; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 6 ft overhang (5.25 ft window ht, 1 ft sep.); 6.8 ft head ht 27912.31988.7000.30023w Non-Impact: Non-Impact; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (0.67 ft window ht, 1 ft sep.); 6.8 ft head ht 3318.3147.8300.2702nw Non-Impact: Non-Impact; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 11.5 ft overhang (6.7 ft window ht, 1 ft sep.); 6.8 ft head ht 36120.21719.5700.33018nw Doors Fbrgls Door 893.73893.697.00.12724ne Ceilings 2021-Jul-12 09:41:12 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W Attic, Shngl Roof, R-30 Ceil Ins, 5/8" Gyp Bd 0.0341980 28851.4619550.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00662328.700.989231 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Project Summary 7/12/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hood Residence, Groza Builders, IncFor:TBD Pinetree Dr, Fort Pierce, FL 34982 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18066 Structure Btuh15239 Ducts Btuh6292 Ducts Btuh7048Central vent (57 cfm) 1826 Btuh Central vent (57 cfm) Btuh970 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh26185 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh22187 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3226 Ducts Btuh2118Central vent (57 cfm) Btuh2214 CoolingHeating Outside air19801980Area (ft²) Equipment latent load Btuh7558 1728217282Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh29745 Equiv. AVF (cfm) 58109 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make LennoxTrade Trade LENNOX Model Cond ML14XC1S036-230C**AHRI ref Coil CBA27UHE-036-230*++TDR AHRI ref 204289057Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.6 Sensible cooling Btuh24220Heating output Btuh26063 Latent cooling Btuh10380 Temperature rise °F21 Total cooling Btuh34600Actual air flow cfm1153 Actual air flow cfm1153 Air flow factor cfm/Btuh0.047 Air flow factor cfm/Btuh0.052Static pressure in H2O0.85 Static pressure in H2O0.85 Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Foyer 2 Exposed wall 230.9 ft 15.5 ft 3 Room height 8.7 ft 8.5 heat/coolft 4 Room dimensions ft15.0x5.0 5 Room area 1979.9 ft²75.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 183 135 349 223 43 19 48 30 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 23 0 195 407 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 24 24 89 89 24 24 89 89 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 486 447 1151 736 0 0 0 0 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 16 2 136 272 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 23 3 202 382 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 372 356 917 586 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 16 2 136 272 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 49 27 69 44 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 23 17 198 279 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 519 483 1245 796 0 0 0 0 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 2 0 14 33 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 16 0 136 284 0 0 0 0 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 18 0 171 361 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 338 338 994 493 89 89 262 130 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 1980 1980 1955 2885 75 75 74 109 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 1980 231 6623 0 75 16 445 0 6 c) AED excursion 318 -13 Envelope loss/gain 14578 8464 917 347 12 a) Infiltration 3488 975 92 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 5 1150 0 0 Appliances/other 4650 0 Subtotal (lines 6 to 13)18066 15239 1009 372 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 96 35 14 Subtotal 18066 15239 1105 408 15 Duct loads 35%46%6292 7048 35%46%385 189 Total room load 24358 22287 1490 597 Air required (cfm)Air required (cfm)1153 1153 71 31 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Suite M Hall 2 Exposed wall 37.0 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft15.0x17.5 ft4.5x4.5 5 Room area 262.5 ft²20.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 140 117 301 192 0 0 0 0 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 23 0 195 407 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 36 36 93 59 0 0 0 0 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 120 120 309 198 0 0 0 0 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 263 263 259 383 20 20 20 30 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 263 37 1061 0 20 0 0 0 6 c) AED excursion -14 -1 Envelope loss/gain 2218 1226 20 29 12 a) Infiltration 642 179 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)2860 1905 20 29 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 5 7 -20 -29 14 Subtotal 2865 1912 0 0 15 Duct loads 35%46%998 884 35%46%0 0 Total room load 3863 2797 0 0 Air required (cfm)Air required (cfm)183 145 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 3...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bath Linen 2 Exposed wall 9.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft113.0x1.0 ft3.5x3.0 5 Room area 113.0 ft²10.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 76 74 191 122 0 0 0 0 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 2 0 14 33 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 113 113 112 165 11 11 10 15 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 113 10 272 0 11 0 0 0 6 c) AED excursion 7 -1 Envelope loss/gain 589 327 10 15 12 a) Infiltration 165 46 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)754 373 10 15 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 10 15 -10 -15 14 Subtotal 764 387 0 0 15 Duct loads 35%46%266 179 35%46%0 0 Total room load 1030 567 0 0 Air required (cfm)Air required (cfm)49 29 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 4...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name WIC Pantry 2 Exposed wall 19.5 ft 5.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.5x13.0 ft4.5x5.0 5 Room area 84.5 ft²22.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 104 104 268 171 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 52 52 134 86 0 0 0 0 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 40 40 118 58 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 85 85 83 123 23 23 22 33 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 85 20 559 0 23 5 143 0 6 c) AED excursion -16 -3 Envelope loss/gain 1045 365 283 88 12 a) Infiltration 338 95 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1383 459 283 88 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 2 3 -283 -88 14 Subtotal 1385 462 0 0 15 Duct loads 35%46%482 214 35%46%0 0 Total room load 1868 676 0 0 Air required (cfm)Air required (cfm)88 35 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 5...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Laundry Kit/DR/GR 2 Exposed wall 24.0 ft 45.9 ft 3 Room height 8.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft8.0x8.0 ft702.9x1.0 5 Room area 64.0 ft²702.9 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 64 64 165 105 190 167 430 275 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 0 0 0 0 23 3 202 382 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 64 64 165 105 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 49 27 69 44 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 0 0 0 0 23 17 198 279 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 0 0 0 0 75 57 147 94 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 18 0 171 361 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 64 64 188 93 145 145 426 212 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 64 64 63 93 703 703 694 1024 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 64 24 688 0 703 46 1317 0 6 c) AED excursion -32 146 Envelope loss/gain 1269 365 3653 2817 12 a) Infiltration 278 78 682 191 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 5 1150 Appliances/other 500 2900 Subtotal (lines 6 to 13)1547 943 4335 7058 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 206 80 14 Subtotal 1547 943 4541 7138 15 Duct loads 35%46%539 436 35%46%1582 3301 Total room load 2086 1379 6123 10439 Air required (cfm)Air required (cfm)99 71 290 540 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 6...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath Hall 2 Exposed wall 5.5 ft 0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft5.5x11.0 ft13.5x4.0 5 Room area 60.5 ft²54.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 44 44 113 73 0 0 0 0 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 61 61 60 88 54 54 53 79 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 61 6 158 0 54 0 0 0 6 c) AED excursion -6 -3 Envelope loss/gain 331 154 53 76 12 a) Infiltration 95 27 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)426 181 53 76 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 8 12 -53 -76 14 Subtotal 435 193 0 0 15 Duct loads 35%46%151 89 35%46%0 0 Total room load 586 282 0 0 Air required (cfm)Air required (cfm)28 15 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 7...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Bed 3 2 Exposed wall 13.5 ft 13.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft13.5x10.5 ft13.0x11.0 5 Room area 141.8 ft²143.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 108 92 237 151 0 0 0 0 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 16 2 136 272 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 0 0 0 0 104 88 226 145 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 0 0 0 0 16 0 136 284 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 142 142 140 207 143 143 141 208 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 142 14 387 0 143 13 373 0 6 c) AED excursion 94 98 Envelope loss/gain 900 725 876 735 12 a) Infiltration 234 65 225 63 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 250 Subtotal (lines 6 to 13)1134 1040 1102 1048 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 21 29 12 17 14 Subtotal 1155 1069 1114 1066 15 Duct loads 35%46%402 495 35%46%388 493 Total room load 1557 1564 1502 1558 Air required (cfm)Air required (cfm)74 81 71 81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 8...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name WIC2 WIC3 2 Exposed wall 12.0 ft 5.0 ft 3 Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft6.0x6.0 ft6.0x5.0 5 Room area 36.0 ft²30.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nene 2.582.58 1.651.65 0 0 0 0 0 0 0 0 .GG Non-ImpactNon-Impact 0.2900.290 nene 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 .DD Fbrgls DoorFbrgls Door 0.1270.127 nene 3.693.69 3.733.73 0 0 0 0 0 0 0 0 .WW Block R-9 WallBlock R-9 Wall 0.0890.089 sese 2.582.58 1.651.65 0 0 0 0 0 0 0 0 11 GG Non-ImpactNon-Impact 0.2900.290 sese 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 sese 8.708.70 16.4816.48 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 swsw 2.582.58 1.651.65 48 48 124 79 40 40 103 66 GG Non-ImpactNon-Impact 0.2900.290 swsw 8.418.41 16.8316.83 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 ww 2.582.58 1.651.65 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3000.300 ww 8.708.70 12.2712.27 0 0 0 0 0 0 0 0 WW Block R-9 WallBlock R-9 Wall 0.0890.089 nwnw 2.582.58 1.651.65 48 48 124 79 0 0 0 0 GG Non-ImpactNon-Impact 0.2700.270 nwnw 7.837.83 18.3518.35 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.2900.290 nwnw 8.418.41 17.5717.57 0 0 0 0 0 0 0 0 GG Non-ImpactNon-Impact 0.3300.330 nwnw 9.579.57 20.2320.23 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.461.46 36 36 36 52 30 30 30 44 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 36 12 344 0 30 5 143 0 6 c) AED excursion -9 -4 Envelope loss/gain 627 202 276 105 12 a) Infiltration 208 58 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)835 260 363 129 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 835 260 363 129 15 Duct loads 35%46%291 120 35%46%126 60 Total room load 1126 380 489 189 Air required (cfm)Air required (cfm)53 20 23 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-12 09:41:12Right-Suite® Universal 2021 21.0.07 RSU29066 Page 9...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Right-J® Worksheet 7/12/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 4 2 Exposed wall 25.5 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft11.0x14.5 5 Room area 159.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W Block R-9 Wall 0.089 ne 2.58 1.65 0 0 0 0 .G Non-Impact 0.290 ne 8.41 17.57 0 0 0 0 .D Fbrgls Door 0.127 ne 3.69 3.73 0 0 0 0 .W Block R-9 Wall 0.089 se 2.58 1.65 88 88 227 145 11 G Non-Impact 0.290 se 8.41 16.83 0 0 0 0 G Non-Impact 0.300 se 8.70 16.48 0 0 0 0 W Block R-9 Wall 0.089 sw 2.58 1.65 116 100 257 164 G Non-Impact 0.290 sw 8.41 16.83 16 2 136 272 W Block R-9 Wall 0.089 w 2.58 1.65 0 0 0 0 G Non-Impact 0.300 w 8.70 12.27 0 0 0 0 W Block R-9 Wall 0.089 nw 2.58 1.65 0 0 0 0 G Non-Impact 0.270 nw 7.83 18.35 0 0 0 0 G Non-Impact 0.290 nw 8.41 17.57 0 0 0 0 G Non-Impact 0.330 nw 9.57 20.23 0 0 0 0 P Frm Wall, 1/2" Gyp B 0.101 -2.94 1.46 0 0 0 0 C Attic, Shngl Roof, R 0.034 -0.99 1.46 160 160 157 232 F On Grade Depth, Tile 0.989 -28.68 0.00 160 26 731 0 6 c) AED excursion 74 Envelope loss/gain 1509 889 12 a) Infiltration 442 124 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 250 Subtotal (lines 6 to 13)1951 1262 Less external load 0 0 Less transfer 0 0 Redistribution 6 9 14 Subtotal 1957 1271 15 Duct loads 35%46%682 588 Total room load 2639 1859 Air required (cfm)125 96 2021-Jul-12 09:41:13 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Duct System Summary 7/12/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hood Residence, Groza Builders, IncFor: TBD Pinetree Dr, Fort Pierce, FL 34982 CoolingHeating External static pressure in H2O0.85in H2O0.85 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.85in H2O0.85 Supply / return available pressure 0.526 / 0.324 in H2O in H2O0.526 / 0.324 Lowest friction rate in/100ft0.281in/100ft0.281 Actual air flow cfm1153cfm1153 Total effective length (TEL) ft302 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st2100.037.6VlFx0x04.00.3821833586hBath st2100.036.9VlFx0x06.00.38497881564cBed 2 st2100.039.2VlFx0x06.00.37797851558cBed 3 st4125.056.8VlFx0x07.00.2891151502639hBed 4 st3110.040.6VlFx0x05.00.34937851490hFoyer st195.014.2VlFx0x06.00.481162872610cKit/DR/GR st3110.044.8VlFx0x07.00.340162872610cKit/DR/GR-A st2100.037.4VlFx0x07.00.383162872610cKit/DR/GR-B st2100.036.8VlFx0x07.00.384162872610cKit/DR/GR-C st195.012.2VlFx0x06.00.490861182086hLaundry st3110.036.8VlFx0x05.00.35835591030hMaster Bath st3110.031.3VlFx0x06.00.372871101931hMaster Suite st3110.039.1VlFx0x06.00.352871101931hMaster Suite-A st3110.041.5VlFx0x06.00.347421061868hWIC st4125.061.7VlFx0x05.00.28124641126hWIC2 st4125.056.2VlFx0x04.00.2901228489hWIC3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 205 248 0.481 709 8.0 0x0 VinlFlx st4 Peak AVF 242 151 0.281 692 8.0 0x0 VinlFlx st2 st2 Peak AVF 623 686 0.281 874 12.0 0x0 VinlFlx st3 Peak AVF 556 450 0.340 707 12.0 0x0 VinlFlx Bold/italic values have been manually overridden 2021-Jul-12 09:41:13 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb5 0x 1780 127 115.3 0.281 402 9.0 x0 0 VlFx rt1 rb3 0x 1490 120 106.0 0.306 559 7.0 x0 0 VlFx rt1 rb4 0x 880 97 101.4 0.320 278 8.0 x0 0 VlFx rt1 rb1 0x 4100 253 50.0 0.649 522 12.0 x0 0 VlFx rb2 0x 5580 786 93.9 0.345 563 16.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 973 1131 0.281 640 18.0 0x0 VinlFlx 2021-Jul-12 09:41:13 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...cuments\Wrightsoft HVAC\TBD Pinetree Dr GBI.rup Calc = MJ8 Front Door faces: W 1556Job:Manual S Compliance Report 7/12/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Hood Residence, Groza Builders, IncFor: TBD Pinetree Dr, Fort Pierce, FL 34982 Cooling Equipment Design Conditions °F76.9Entering coil DB:Btuh23257Sensible gain:°F90.4Outdoor design DB: °F64.1Entering coil WB:Btuh7558Latent gain:°F77.4Outdoor design WB: Btuh30815Total gain:°F75.0Indoor design DB: cfm1153Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: ML14XC1S036-230C**+CBA27UHE-036-230*++TDRModel:LennoxManufacturer: cfm1153Actual airflow: % of load104Btuh24220Sensible capacity: % of load137Btuh10380Latent capacity: %70SHR:% of load112Btuh34600Total capacity: Heating Equipment Design Conditions °F68.0Entering coil DB:Btuh26185Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm1153Actual airflow: °F50Temp. rise:% of load100kW7.6Output capacity: Meets all requirements of ACCA Manual S.