HomeMy WebLinkAboutAPPROVED 118197 - Greene Property - SS CD Rev 0_070621 - esign(1)TITLE SHEETPREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONT-1DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637SITE NUMBER:118197SITE NAME:GREENE PROPERTYSTRUCTURE TYPE:250' SELF SUPPORT TOWERMARKET: JUPITERPROJECT TYPE: SUB-6118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21CONTACT INFORMATIONSITE DIRECTIONSLIST OF DRAWINGSLOCATION SKETCHAPPROVALSPROPERTY OWNER: _________________________________________________________________RF ENGINEER: ______________________________________________________________________CONSTRUCTION: ____________________________________________________________________SITE ACQUISITION: __________________________________________________________________ZONING: ___________________________________________________________________________NETWORK: _________________________________________________________________________OPERATIONS: ______________________________________________________________________SITE INFORMATIONAPPLICABLE CODESSCOPE OF WORKPARCEL ID #:LATITUDE:LONGITUDE:1112-441-0001-000/927° 31' 52.7016" NORTH (NAD 83)80° 34' 47.7012" WEST (NAD 83)APPLICANT:VERIZON WIRELESS7701 E TELECOM PKWYTEMPLE TERRACE, FL 33637ARCHITECT/ ENGINEER:CBVR/ HUGH O. REILLY, PE6505 N HIMES AVETAMPA, FL 33614JURISDICTION:ST. LUCIE COUNTYT-1TITLE SHEETSITE GENERAL ARRANGEMENT PLANSARCHITECTURAL/ CIVIL PLANSC-2EQUIPMENT AREA PLANC-3TOWER ELEVATION & ANTENNA MOUNT DETAILSELECTRICAL PLANSC-5EQUIPMENT DETAILS AND PROPOSED ANTENNA & CABLESCHEDULEE-1GROUNDING DETAILSC-1COMPOUND PLANTHE SCOPE OF WORK CONSISTS OF MODIFYING COMMUNICATIONSINSTALLATION ON AN EXISTING TOWER:EQUIPMENT PAD:·REMOVE (1) 6101 CABINET W/ BBU·REMOVE 30KW LP GENERATOR·REMOVE DISCONNECT, MTS, ATS, ELECTRICAL MAIN AND SUBPANELS·INSTALL (1) 200A ILC·INSTALL 50KW LP GENERATOR·INSTALL (1) CHARLES CUBE CABINET·INSTALL (2) OVP-12'STOWER/ RAD:·REMOVE (9) ANTENNAS (3 PER SECTOR)·REMOVE (6) 1-5/8" COAX CABLES·INSTALL ANTENNA MOUNTS REINFORCEMENTS PER MASERCONSULTING (ALPHA SECTOR ONLY)·INSTALL (3) AIR 6449 ANTENNAS (1 PER SECTOR)·INSTALL (3) LTE ANTENNAS (1 PER SECTOR)·INSTALL (3) TWIN DIPLEXERS (1 PER SECTOR)·INSTALL (3) RRU4449'S AND (3) RRU8843'S (1 OF EACH PER SECTOR)·INSTALL (2) OVP-12'S AND (2) 12/24 HYBRID CABLES.- FLORIDA BUILDING CODE 2020 (7th EDITION)WIND DESIGN CRITERIAA. ASCE 7 - 16ULTIMATE WIND SPEED = 160 MPHRISK CATEGORY = IIEXPOSURE = CB. ANSI/ TIA-222-HSTRUCTURE CLASS = IITOPOGRAPHIC CATEGORY = 1-FLORIDA FIRE PREVENTION CODE - 2020 (7TH EDITION)-NATIONAL ELECTRIC CODE (NFPA 70-2017)-CITY AND OR COUNTY ORDINANCESC-4EQUIPMENT DETAILSFrom FL-706 & FL-811 (Jupiter):1.Head west on FL-706 W/W Indiantown Rd toward N Orange Ave (go 2.9 mi)2.Continue straight onto W Indiantown Rd (go 0.2 mi)3.Slight right to merge onto I-95 N toward Daytona Bch (go 0.8 mi)4.Merge onto I-95 N (go 18.2 mi)5.Keep left to stay on I-95 N (go 19.8 mi)6.Take exit 126 for County Rd 712/Midway Rd (go 0.4 mi)7.Keep left at the fork, follow signs for Fairgrounds (go 276 ft)8.Turn left onto W Midway Rd (go 4.9 mi)9.Turn left onto FL-70 W (go 2.8 mi)10.Turn right onto State Hwy 613 (go 5.6 mi)11.Turn left onto Orange Ave (go 1.8 mi)12.Turn right onto Minute Maid Rd (go 2.9 mi)13.Turn left (go 3.7 mi)14.Turn left onto 122nd Ave SW (go 184 ft)15.Destination will be on the leftSITE LOCATIONTOWER OWNER:SBA TOWERS, LLC8051 CONGRESS AVENUEBOCA RATON , FL 33487C-6GENERATOR DETAILSE-2ELECTRICAL DETAILS
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X
X
X XXXXPREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-1DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21COMPOUND PLANCOMPOUND PLAN5'10'11x17 SCALE: 1"=10'GRAPHIC SCALE(SCALE IN FEET)0'NOTES:·ALL DRAWINGS HAVE BEEN PREPARED WITHOUT THE AID OF A SURVEY OR A TITLE·ALL DIMENSIONS, PROPERTY LINES, AND RIGHT OF WAYS ARE APPROXIMATE BASED UPON AVAILABLE ONLINE RESOURCES·CONTRACTOR SHALL RESTORE AND REPAIR ANY DAMAGED AREAS CAUSED BY CONSTRUCTION TO ORIGINAL OR BETTER CONDITION·ALL NEW WORK TO BE PERFORMED PER LATEST VERIZON WIRELESS STANDARDS & SPECIFICATIONSEXISTING VERIZON WIRELESSEQUIPMENT CONCRETE PADEXISTING VERIZON WIRELESS500GAL LP TANK ON CONCRETE PADEXISTING 250'SELF-SUPPORT TOWEREXISTING VERIZONWIRELESS UTILITY H-FRAMEEXISTING DOUBLE SWINGACCESS GATEEXISTING CHAINLINK FENCEEXISTING VERIZON WIRELESS30KW LP GENERATOREXISTING GAS LINE SIZE TO BE FIELD VERIFIED. IF PIPESIZE IS LESS THAN 3/4" DIA, REPLACE WITHPOLYETHYLENE PLASTIC PIPE PER FBC TABLE (402.4(36))
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
G
GGG
GGGGGPREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-2DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21EQUIPMENT AREA PLANEXISTING EQUIPMENT LAYOUT2.5'5'11x17 SCALE: 1"=5'GRAPHIC SCALE(SCALE IN FEET)0'1TELCO BOX2TELCO CABINET3METER4TOWER LIGHT SYSTEM BOX5MICROWAVE PRIMARY CABINET6EBRE BATTERY CABINET74.0B BTS CABINET W/ BBU8DISCONNECT (TO BE REMOVED)9ATS (TO BE REMOVED)10MTS W/ GEN PLUG (TO BE REMOVED)11MAIN ELECTRICAL PANEL (TO BE REMOVED)12ELECTRICAL SUB PANEL (TO BE REMOVED)1330KW LP GENERATOR (TO BE REMOVED)146101 CABINET W/ BBU (TO BE REMOVED)LEGENDPROPOSED EQUIPMENT LAYOUT2.5'5'11x17 SCALE: 1"=5'GRAPHIC SCALE(SCALE IN FEET)0'NOTE:ALL EXISTING AND PROPOSED EQUIPMENT CONFIGURATIONSSHALL BE FIELD VERIFIED AND CONFIRMED BY GC WITH THEVERIZON WIRELESS CONSTRUCTION MANAGER.#2 AWG SOLID TINNED COPPER GROUNDCONNECTION, BOND TO EXISTING GROUNDSYSTEM (TYP. ON NEW EQUIPMENT)EXISTING GROUND CONNECTION TOEXISTING GROUND SYSTEM (TYP.)13943428101112556714131TELCO BOX2TELCO CABINET3METER4TOWER LIGHT SYSTEM BOX5MICROWAVE PRIMARY CABINET6EBRE BATTERY CABINET74.0B BTS CABINET W/ BBU8PROPOSED 200A ILC9PROPOSED OVP-1210PROPOSED 50KW LP GENERATOR11PROPOSED CHARLE CUBE CABINETLEGEND134342855671110EXISTING GAS LINE SIZE TO BE FIELDVERIFIED. IF PIPE SIZE IS LESS THAN 3/4"DIA, REPLACE WITH POLYETHYLENEPLASTIC PIPE PER FBC TABLE (402.4(36))99
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-3DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21NOTES:1.CONTRACTOR TO FIELD VERIFY ANTENNA MOUNT CONFIGURATION AND PROVIDE MOUNTS OR ADDITIONAL HARDWAREIF REQUIRED TO SUPPORT PROPOSED EQUIPMENT.2.ALL EQUIPMENT AND MOUNTING HARDWARE SHALL CONFORM TO DESIGN REQUIREMENTS PER FLORIDA BUILDINGCODE (7TH EDITION, 2020) AND ANSI/ TIA-222-H STRUCTURAL STANDARD FOR ANTENNA SUPPORTING STRUCTURES ANDANTENNAS; ULTIMATE WIND SPEED 160 MPH, 3 SECOND GUST.3.AZIMUTH INFO TAKEN FROM VERIZON WIRELESS RF SITE DESIGN DATA. TOWER AND ANTENNAS HEIGHTS TAKEN FROMRECENT TOWER SURVEY DATA.4.REFERENCE STRUCTURAL ANALYSIS REPORT BY TOWER ENGINEERING SOLUTIONS, LLC., DATED 05/26/2021.EXISTING ANTENNA MOUNT DETAILNOT TO SCALETOWER ELEVATION &ANTENNA MOUNT DETAILSNOTE:CONTRACTOR TO FIELD VERIFY ANTENNA MOUNT CONFIGURATIONAND PROVIDE MOUNTS OR ADDITIONAL HARDWARE PERMANUFACTURER RECOMMENDATIONS, AND REFERENCESTRUCTURAL ANALYSIS PER MASER CONSULTING, DATED 04/09/21.1 X7-665-4 ANTENNA (TO BE REMOVED)2X7C-FRO-640-4 ANTENNA (TO BE REMOVED)3X7CAP-665-42 ANTENNA (TO BE REMOVED)4UNKNOWN ANTENNA (TO BE REMOVED)LEGENDFAA NOTE:FAA APPROVED OVERALLHEIGHT = 290' AGLPROPOSED ANTENNA MOUNT DETAILNOT TO SCALEEXISTING VERIZONWIRELESS ICE BRIDGEEXISTING VERIZONWIRELESS EQUIPMENT PADEXISTING 250'SELF-SUPPORT TOWERTOP OF TOWEREL. 250' AGLRAD CENTER OF EXISTING AND PROPOSEDVERIZON WIRELESS ANTENNASEL. 249.3' AGLEXISTING VERIZON WIRELESS (12) 1-5/8" COAXCABLES ROUTED ON TOWER, (6) TO BE REMOVEDPROPOSED VERIZON WIRELESS (2) 12/24HYBRID CABLES TO BE ROUTED ON TOWER1 PROPOSED NNH4-65B-R6 ANTENNA2PROPOSED AIR6449 ANTENNA3PROPOSED RRU44494PROPOSED RRU88435PROPOSED CBC1923T-DS-43 TWIN DIPLEXER6PROPOSED OVP-12LEGENDAZ= SECTOR A165.00°TOWER ELEVATIONNOT TO SCALEA
Z
=
S
E
C
T
O
R
B
2
2
0
.
0
0
°AZ= SECTOR C290.00°323414424EXISTING 250'SELF-SUPPORT TOWEREXISTING LOW PROFILE ANTENNA MOUNTTO BE REINFORCED (BETA SECTOR ONLY)AZ= SECTOR A165.00°A
Z
=
S
E
C
T
O
R
B
2
2
0
.
0
0
°AZ= SECTOR C290.00°211212EXISTING 250'SELF-SUPPORT TOWEREXISTING REINFORCED LOW PROFILEANTENNA MOUNT (TYP. EACH SECTOR)EXISTING LOW PROFILE ANTENNA MOUNTTO REMAIN (ALPHA AND GAMMA SECTORS)EXISTING REINFORCED LOW PROFILE ANTENNAMOUNT (ALPHA SECTOR ONLY) PER MASERCONSULTING GROUP DRAWINGS, DATED 04/09/21.34665553434
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-4DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21EQUIPMENT DETAILSRADIO PIPE MOUNT DETAILPROPOSED MOUNT PIPE(ATTACHED TO WALL ORFRAME AS NECESSARY)PROPOSED POLE CLAMP ANDHARDWARE SUPPLIED WITHRRU. INSTALL PERMANUFACTURER'SSPECIFICATIONSPROPOSED RADIOOVP-12 DETAILSCALE : 1"=1'FRONT VIEWSIDE VIEWBOTTOM VIEWMANUFACTURER:VERIFY WITH VZW CX PMMODEL#:VERIFY WITH VZW CX PMDIMENSIONS (WxDxH):VERIFY WITH VZW CX PMWEIGHT:VERIFY WITH VZW CX PM42016.574929.531912.6RRU4449 DETAILRRU8843 DETAILAIR 6449 SPECIFICATIONS
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-5DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21EQUIPMENT DETAILS AND PROPOSED ANTENNA &CABLE SCHEDULEPROPOSED EQUIPMENT IN BOLD*REFER TO RFDS**(6) 1-5/8" COAX CABLES TO BE REMOVED.NOTES:1.VERIZON WIRELESS CURRENTLY HAS (12) 1-5/8" COAX CABLES INSTALLED.2.LENGTH FOR PROPOSED HYBRID FIBER CABLE IS FROM VERIZON WIRELESS OVP AT EQUIPMENT TO VERIZON WIRELESS RAD CENTER.3.REQUEST CURRENT RFDS BEFORE INSTALLATION.4.ALL VERIZON WIRELESS ANTENNA AND CABLE DATA BASED ON ASSUMED ANTENNA HEIGHT, CONTRACTOR SHALL VERIFY PROPOSED ANTENNA HEIGHT PRIOR TOINITIATION OF CONSTRUCTION ACTIVITIES, INCLUDING, BUT NOT LIMITED TO, ORDERING OF ANY ANTENNA OR CABLE MOUNTING HARDWARE.CUBE-SS4B228LX1 CABINET DETAIL
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-6DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21GENERATOR DETAILS
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONE-1DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21TO GROUND RINGPARALLEL EXOTHERMIC WELDSCALE : N.T.S.SCALE : N.T.S.SCALE : N.T.S.GROUNDING DETAILS1.DO NOT INSTALL CABLE GROUND KIT AT A BEND ANDALWAYS DIRECT GROUND WIRE DOWN TO GROUNDBAR2.GROUNDING KIT SHALL BE TYPE AND PART NUMBERAS SUPPLIED OR RECOMMENDED BY CABLEMANUFACTURER.3.WEATHERPROOFING SHALL BE TYPE AND PARTNUMBER AS SUPPLIED OR RECOMMENDED BY CABLEMANUFACTURER.4.BUTYL TAPE WEATHERPROOFING MUST FOLLOWMANUFACTURER'S INSTALLATION INSTRUCTIONS WITHTHE FOLLOWING MODIFICATION: ON THE FIRST TAPEPASS PROVIDE A COURTESY WRAP TO AVOIDPERMANENTLY ADHERING TO THE COAX CONNECTOR.5.START TAPE APPROXIMATELY 5 INCHES FROM THECONNECTOR AND WRAP 2 INCHES TOWARD THECONNECTOR, THEN REVERSE THE TAPE A HALF TURNOR SO THAT THE STICKY SIDE IS UP. CONTINUEWRAPPING THE TAPE OVER THE CONNECTOR UNTIL 3INCHES BEYOND THE CONNECTOR AND REVERSE THETAPE A HALF TURN AGAIN OR SO THAT THE STICKYSIDE IS DOWN FOR ANOTHER 2 INCHES.6.WHEN APPLIED, THE TAPE MUST BE ABOVE 32°F (0°C)TO ENSURE ADHESION7.DO NOT STRETCH THE TAPE AND DO NOT PULL THETAPE TO TEAR IT - ALWAYS CUT IT. PULLED TAPEEVENTUALLY UNRAVELS, DECREASING POSITION.8.TIGHTLY WRAP THE RUBBER TAPE WITH 2 LAYERS OFVINYL INSULATING TAPE.NOTES:WEATHERPROOFINGKIT (SEE NOTE 3)COAX CABLE GROUNDINGCLAMP KIT#6 AWG STRANDED CUWIRE WITH GREEN, 600V,THWN INSULATION(GROUNDED TO GROUNDBAR) (SEE NOTES 1 & 2)COAX CABLE TOANTENNA OR TMACOAX CABLE TOEQUIPMENT AT GRADENOTES:1.ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING SPLIT WASHERS.2.COAT WIRE END WITH ANTI-OXIDATION COMPOUND PRIOR TO INSERTION INTO LUG BARREL AND CRIMPING.3.APPLY ANTI-OXIDATION COMPOUND BETWEEN ALL LUGS AND BUSS BARS PRIOR TO MATING AND BOLTING.TIN COATED-SOLID COPPER BUSSBAR PER SPECIFICATIONS2 HOLE, LONG BARREL TINNEDSOLID COPPER LUG (TYP.)NOTE: MINIMUM OF 3 THREADSTO BE VISIBLE (TYP.)S/S FLAT WASHER (TYP.)S/S NUT (TYP.)S/S SPLIT WASHER (TYP.)S/S FLATWASHER (TYP.)S/S BOLT (TYP.)CHERRY INSULATORINSTALLED IF REQUIREDPER SPECIFICATIONSSCALE : N.T.S.SCALE : N.T.S.NOTE:CONTRACTOR TO APPLYCOPPERSHIELD OR NO-OX3/8"x3/4" SS BOLT1/4"x4"x12" OR1/4"x4"x20" BUS BARSITE PRO 1PART #'SMG41236 (TYP.)MG42051 (MGB)3/8" LOCK WASHERINSULATOR PART # INS38-KOR APPROVED EQUIVALENT38" GALV. SCREWS2" AWG TINNED WIRELEAD W/ THERMOWELDMOUNTINGBRACKET PART#MT200 ORAPPROVEDEQUIVALENT3/8"x3/4" SS BOLTSS ANGLE ADAPTORPART# MG-ADAP-K ORAPPROVED EQUIVALENT(TOWER MOUNTING KIT)ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF THENATIONAL ELECTRICAL CODE (N.E.C.), AND APPLICABLE LOCAL CODES.GROUNDING SHALL COMPLY WITH ARTICLE 250 OF NATIONAL ELECTRICALCODE.ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED.ALL WIRES SHALL BE AWG MIN #12 THHN COPPER UNLESS NOTED.CONDUCTORS SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT UNLESSNOTED OTHERWISE.ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST ANDSTRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM8" RADIUS.ENGAGE AN INDEPENDENT TESTING FIRM TO TEST AND VERIFY THATRESISTANCE DOES NOT EXCEED 5 OHMS TO GROUND. TEST GROUND RINGRESISTANCE PRIOR TO MAKING FINAL GROUND CONNECTIONS TOINFRASTRUCTURE AND EQUIPMENT. GROUNDING AND OTHER OPERATIONALTESTING SHALL BE WITNESSED BY VERIZON WIRELESSS REPRESENTATIVE.PROVIDE PULL BOXES AND JUNCTION BOXES WHERE REQUIRED SO THATCONDUIT BENDS DO NOT EXCEED 360°.OBTAIN PERMITS AND PAY FEES RELATED TO ELECTRICAL WORKPERFORMED ON THIS PROJECT. DELIVER COPIES OF ALL PERMITS TOVERIZON WIRELESS REPRESENTATIVE.SCHEDULE AND ATTEND INSPECTIONS RELATED TO ELECTRICAL WORKREQUIRED BY JURISDICTION HAVING AUTHORITY. CORRECT AND PAY FORANY WORK REQUIRED TO PASS ANY FAILED INSPECTION.REDLINED AS-BUILTS ARE TO BE DELIVERED TO VERIZON WIRELESSREPRESENTATIVE.ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALLAPPLICABLE BUILDING CODES AND LOCAL ORDINANCES, INSTALLED IN ANEAT MANNER, AND SHALL BE SUBJECT TO APPROVAL BY VERIZONWIRELESS REPRESENTATIVE.CONDUCT A PRE-CONSTRUCTION SITE VISIT AND VERIFY EXISTING SITECONDITIONS AFFECTING THIS WORK. REPORT ANY OMISSIONS ORDISCREPANCIES FOR CLARIFICATION PRIOR TO THE START OFCONSTRUCTION.PROTECT ADJACENT STRUCTURES AND FINISHES FROM DAMAGE. REPAIRTO ORIGINAL CONDITION ANY DAMAGED AREA.REMOVE DEBRIS ON A DAILY BASIS. DEBRIS NOT REMOVED IN A TIMELYFASHION WILL BE REMOVED BY OTHERS AND THE RESPONSIBLESUBCONTRACTOR SHALL BE CHARGED ACCORDINGLY. REMOVAL OF DEBRISSHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE. DEBRISSHALL BE REMOVED FROM THE PROPERTY AND DISPOSED OF LEGALLY.UPON COMPLETION OF WORK, THE SITE SHALL BE CLEAN AND FREE OFDUST AND FINGERPRINTS.ELECTRICAL NOTES:GROUNDING NOTES:ALL DOWN GROUND WIRE AND GROUND SYSTEM WIRE SHALL BE #2 AWG, SOLID,BARE, TINNED COPPER. ALL CONNECTIONS TO GROUND SYSTEM SHALL BEEXOTHERMICALLY WELDED.WHERE MECHANICAL GROUNDING CONNECTIONS ARE SPECIFIED, BOLTED,COMPRESSION-TYPE CLAMPS OR SPLIT-BOLT TYPE CONNECTORS SHALL BE USED.GRIND OFF GALVANIZING IN AFFECTED AREA. EXOTHERMICALLY WELD #2CONDUCTOR. COLD-GALV AFTER. EXOTHERMICALLY WELD OTHER END TOGROUND.FOLLOWING COMPLETION OF WORK, CONDUCT GROUND TEST. SUBMIT WRITTENTEST TO CONSTRUCTION MANAGER AND PROJECT MANAGER.ALL GROUNDING WORK SHALL COMPLY WITH VERIZON WIRELESS STANDARDS.UNLESS NOTED OTHERWISE, ALL GROUNDING SHALL BE IN ACCORDANCE WITHVERIZON WIRELESS'S REQUIREMENTS FOR "BONDING, GROUNDING ANDTRANSIENT PROTECTION FOR CELL SITES", AND "SITE RESISTANCE TO EARTHTESTING". ALL GROUNDING SHALL ALSO COMPLY WITH ALL STATE AND LOCALCODES, AND THE NATIONAL ELECTRICAL CODE (NEC).UNLESS NOTED OTHERWISE, ALL GROUNDING CONNECTIONS SHALL BE MADE BYAN EXOTHERMIC WELD.RESISTANCE TO EARTH TESTING IS REQUIRED PER NEC STANDARDS ON ALL NEWSITES.NEW INSTALLED ANTENNA PIPE MOUNTS SHALL BE EXOTHERMICAL GROUNDED W/#2 AWG SOLID TINNED COPPER TO EXISTING GROUND SYSTEM (EACH SECTOR).ALL NEW COAX OR HYBRID CABLES SHALL BE GROUNDED W/ SUPPLIED GROUNDKIT TO SECTOR GROUND SYSTEM.EXTERIOR GROUND RING. #2SOLID BARE TINNED COPPERGROUNDING CONDUCTORNO SLAG ORDEFORMITIES ALLOWEDEXOTHERMIC WELD(THERMOWELD OREQUIVALENT) PARALLEL, NOT-WELD ALLOWED.MIN. TURNINGRADIUS 45° (TYP.)JUMPER. #2 SOLID BARETINNED COPPERGROUNDING CONDUCTORGROUNDING BAR LUG DETAILSCOAX CABLE GROUNDTYPICAL GROUND BAR DETAILTYP. METALLIC GROUNDING DETAILEXOTHERMIC WELD DETAILMETALLIC BOX, HOUSING ETC.#2 AWG BARE TINNED SOLIDCOPPER WIRE (UNIT BOND)BRASS TWO HOLEMECHANICAL CONNECTORWITH STAINLESS HARDWARE
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONE-2DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101407/06/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637118197GREENE PROPERTY25500 MINUTE MAID ROADFORT PIERCE, FL 34945CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT007.06.21ELECTRICAL DETAILSELECTRICAL DETAILS200ATO UTILITYTRANSFORMER200A ILC2P-200AMP50KWGEN3-#3/0 AWG6 AWG EG2" CONDUITNEL1" CONDUIT FOR GEN CONTROLS & ALARMS4-#12 AWG,1-#12 AWG EG,1" CONDUIT (FOR GEN HEATER & BATT. CHARGER)NOTE: THE GENERATOR USED INCONJUNCTION WITH A 2-POLE ILCWITH A SOLID NEUTRAL IS NOT ASEPARATELY DERIVED SYSTEM.AS SUCH, DO NOT BOND THENEUTRAL TO GROUND AT THEGENERATOR200AINTEGRATEDLOADCENTERCMUTILITY METER200APRIMARYCABINETSERVICE DISCONNECT/FUSED SWITCH4 AWG MBJ4 AWG GECGEN MAINDISCONNECT/FUSED SWITCHGFCIRECPT.LIGHT2-#12 AWG1-#12 AWG EG1" CONDUITBAH CAB.12-#6 AWG (6 PAIRS)#6 AWG EG 1-1/2"LMFC1" CONDUIT FOR GEN & ILC ALARMSELECTRICAL SINGLE LINE DIAGRAM(P) VERIZON WIRELESS ILCCABINET WITH 2P/200AUTILITY BREAKER ANDOPTIONAL 2P/200A CAMLOCK BREAKERMECHANICALLYINTERLOCKED WITHWALKING BEAM TRANSFERSWITCH AND 30 POSITIONLOAD CENTERCAM LOCK(OPTIONAL)PANEL SCHEDULEUSAGEFACTOR135791113151719212325272924681012141618202224262830BUS AMPSPOSL2L1LOADPOLESAMPSL2L1USAGEFACTORBUS AMPSPOSL1L2LOADPOLESAMPSENCLOSURETYPE:MOUNT:MAINBREAKER:RATEDVOLTAGE:PANELNAME:240120VOLTSVZW ILCSURFACE200NEMA 3RAMPSAIC:NEUTRALBAR:BUSRATING:PHASE/WIRE:MODELNUMBER:KEY DOORLATCH:HENGED DOOR:YESYES13200YES65KASCO D300L SERIESFACTORED TOTALAMPSFACTORED SUBTOTAL AMPSFACTORED SUBTOTAL AMPSRECTIFIERRECTIFIERRECTIFIERRECTIFIERFUTURERECTIFIERFUTURERECTIFIER181818181818181818181818GFI RECEPT.685.7587.04036125.75123.0NOTES:1.ALL CONDUCTORS ARE TYPE THWN (75°C) COPPER, UNLESS NOTED OTHERWISE.2.MAXIMUM LENGTH OF RUN FOR RECTIFIER CIRCUITS IS 50FT.3.ASCO INTEGRATED LOAD CENTER INCLUDES 200 AMP MAIN DISCONNECT AND TRANSFER SWITCH FOR PORTABLE OR PERMANENTGENERATOR.4.RECTIFIER LOADS ARE CONSIDERED TO BE NON-CONTINUOUS, BLOCK HEATER AND BATTERY CHARGER ARE INACTIVE WHILE GENERATORIS IN USE.5.IF ADDITIONAL FUTURE LOADS ARE ADDED WHICH CAUSE TOTAL DEMAND TO EXCEED GENERATOR BREAKER SIZE, BACKUP POWERSYSTEM SHALL BE EVALUATED AND UPGRADED AS NECESSARY.PROPOSED LOAD:LOAD CALCULATIONLOADAMPSVOLTAGE: 120/240V SINGLE PHASE 3W 200A125.75TOTAL DEMAND:125.75230A230A230A230A230A230A120A111111111.25111113-#3/0 AWG#6 AWG EG2" CONDUIT20A1SERVICE LIGHT4UL LISTED8-#10 AWG, 1-#10 AWG EG (RECTIFIERCONDUCTORS SHALL BE RATED THHN ORHIGHER) IN (1) 1-1/2" CONDUIT. ROUTECONDUIT ABOVE GROUND SECURED TOEQUIPMENT FRAMEFUTURECABINET6-#10 AWG, 1-#10 EG IN (1)1-1/2" CO. FOR FUTURE REC.2-#12 AWG1-#12 AWG1" CONDUIT3-#3/0 AWG IN (1)2" CONDUIT3-#3/0 AWG IN (1)2" CONDUIT2P - 200/200 CLF 100KAIC,SERVICE DISCONNECT/ SERATED NEMA 3R MAIN DISC.1" CONDUIT WITH CAT 5 CABLEFOR LP TANK FUEL GAUGEALARMS(PASS THROUGH GENERATOR)(E) 500 GALPROPANE TANK(P) VERIZON WIRELESS 50KW120/240V LP GENERATOR WITH200A MAIN BREAKER. GENERATORIS IN A NEMA 3R ENCLOSURE.SUPPLIED WITH 1500W 120VBLOCK HEATER.NOTES:1.ALL EQUIPMENT SHALL BE NEMA 3R RATED.2.ALL EQUIPMENT SHALL BE LIGHTNING PROTECTED IN ACCORDANCE WITH TIA-222-H AND VERIZON WIRELESS STANDARDS.3.BELOW GRADE CONDUIT SHALL BE SCHEDULE 80 PVC. ABOVE GRADE CONDUIT SHALL BE GALVANIZED RIGID CONDUIT. BELOW GRADE PVC CONDUIT SHALL TRANSITION TO GRCPRIOR TO RISING ABOVE GRADE. ALL BENDS SHALL HAVE A MINIMUM 24" RADIUS. ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIGID CONDUIT. VERIFY CONDUITTYPE WITH LOCAL CONSTRUCTION MANAGER AND ADJUST IF NECESSARY. ALL CONDUIT SHALL MEET NEC, STATE, AND LOCAL CODE REQUIREMENTS AS REQUIRED.4.DIAGRAM SHOWN FOR TYPICAL CONFIGURATION. VERIFY ALL EQUIPMENT, BREAKERS, CONDUIT, AND CONDUCTORS WITH FIELD CONSTRUCTION MANAGER PRIOR TOCONSTRUCTION.BLOCK HEATER12120A1.25BATT.CHARGER5120A1.25