Loading...
HomeMy WebLinkAboutEngineering Re-roof letter�#v T.E. S C H LITT E N G I N E E R I N G October 14, 2021 Mr. Douglas Harvey, Building Supervisor/Building Official St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Subject: Re -Roof Letter — Cox Residence Flat Roof Area Per Attached Sketch 7410 James Road Fort Pierce, FL 34982 Engineer's Project Number: 21FO30 Dear Mr. Harvey: RECEIV D - OCT 2 1202 ST. Lucie County, Permitting The above referenced project has existing roof covering systems that will be removed down to the wood deck. The new roof systems will be installed per the following specifications. Project Design Parameters • Florida Building Code: Seventh Edition • Building Occupancy Category: II • Internal Pressure: Enclosed • Wind Speed: Ultimate: 158 MPH • Nominal / Allowable: 123 MPH • Wind Exposure Category: C • Size of Building (WxL): 50'x60' • Height of Building: 10'-0" • Slope of Roof Area: Sloped and Flat/Low Sloped • Edge Zone: 4' • Corner: 4' x 4' The existing roof covering and underlayment shall be removed, and the existing wood deck shall be verified to be in sound condition. Any necessary sheathing repairs shall be performed per code with minimum size of sheathing repairs to span three rafters/trusses (approximately 48"). The existing deck and any repairs shall be re -nailed per current code requirements. Roof Material Specifications for the Flat Roof Florida Product Approvals: FL 2533.1 R26 CertainTeed, LLC Modified Bitumen Roof System W-67 UnderlaymentSystem: 75# base sheet mechanically attached 1555 Indian River Blvd., Suite B-145 Vero Beach, FL 32960 ittengineering.com 11 Mr. Harvey October 14, 2021 EPN: 21F030 Page 2 The underlayment system shall be installed over minimum 19/32" thick, APA rated plywood. The base layer shall be one of the following: Glasbase Base Sheet; Flintlastic Base 20; Flintlastic Poly MSM Base Sheet, or Flintlastic Ultra Poly SMS Base Sheet with FlintFast 3 in. Insulation Plates with FlintFast #14; orTrufast 3" Metal Insulation Plates with Trufast HD fastened perthe schedule below: Zone Effective Area (minimum) Nominal (ASD) Wind Load Pressure Maximum Pressure per method of Manufacturer +PSF -PSF We 96 SF 10.6 40.8 -105.0 PSF 2 96 SF 10.6 54.2 -105.0 PSF 3 16 SF 12.7 87.5 -105.0 PSF All areas shall be fastened at 4" on center at 3" lap and 4" on center at four (4) equally spaced, staggered center rows. First Ply Roof Coverinq System: SBS-SA-H The first ply shall be Black Diamond Base Sheet with 4" side laps and 6" end laps with end laps diagonally staggered not less than 3' apart. Roof Covering System: SBS-AA, SBS-TA, or APP-TA The bonded roof cover shall be one of the following specifications, all three are approved for this use. The contractor shall pick only one for the entire area unless approved by the manufacturer. 1. SBS-AA: Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P, Flintastic GMS or any of these products in Coolstar type in hot asphalt at 20-40 Ibs/square. 2. SBS-TA: Flintlastic FR Cap 30, Flintlastic GTS-FR or either of these products in Coolstar type as Torch -Applied. 3. APP-TA: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA Coolstar, Flintlastic GTA-FR, Flintlastic GTA-FR Coolstar as Torch -Applied. Roof Material Specifications for the Sloped Roof FL 17322.1-R8 Atlas Roofing WeatherMaster Underlayment, FL 16305-R10 Atlas Shingles Follow manufacturers product application requirements for additional installation requirements. I have reviewed the above information and certify that to my best knowledge and belief; the referenced method of attachment provides adequate resistance to the wind loads and forces 1555 Indian River Blvd., Suite B-145 T: 772.360.4998 Vero Beach, FL 32960 info@schlittengineering.com Mr. Harvey October 14, 2021 EPN: 21FO30 Page 3 specified by current code provisions. Should you have any questions regarding the above subject, please call. Very truly yours, Terence Schlitt, P.E. FL P.E. # 81238 TS/kw cc: Mr. Paul Lucas, Lucas Roofing, Inc. oW i l 11ii// N\\\\�%� * ; No. 81238 * = ' 'I_ STATE OF (V�` /lllllll��� 1555 Indian River Blvd., Suite B-145 Vero Beach, FL 32960 T: 772.360.4998 info@schlittengineering.com