Loading...
HomeMy WebLinkAboutEvaluation ReportCertificate of Authorization No. 29824 L;Kh=K17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, f" EDITION (2020) Manufacturer: ATLAS ROOFING CORPORATION Issued October 16, 2020 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 RECEIVED (770) 612-6267 www.atiasroofina.com OCT 2 1 2021 Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110) 5T. Lucie County, Permitting SCOPE Category: Roofing Subcategory: Underlayments Code Edition: Florida Building Code, 7t' Edition (2017) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1507.1.1, 1518.4, 1523.1.1, 1523.6.5.2.1 Properties: Physical properties REFERENCES Enifty Report No. Standard Year PRI Construction Materials Technologies (TST6049) ATL-033-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049). ATL-068-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) TAS 110 2000 PRI Construction Materials Technologies (TST6049) ATL-069-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-149-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-164-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-254-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) ATL-255-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) BWR-534-02-01 ASTM D 1970 2015a ASTM D 4798 2011(2016) TAS 110 2000 PRI Construction Materials Technologies (TST6049) BWR-543-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01 ASTM D 1970 2015a - PRI Construction Materials Technologies (TST6049) WRMI-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-004-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-007-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST6049) MSA-026-02-01.1 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-030-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-047-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-054-02-01.1 TAS 103 2020 TAS 110 2000 PRI Construction Materials Technologies (TST6049) MSA-057-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) MSA-062-02-01.1 ASTM D 1623 2017 PRI Construction -Materials Technologies (TST6049) 1085T0002 TAS 110 2000 PRI Construction Materials Technologies (TST6049) 1085T0007 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 117T0001 ASTM D 1623 2017 PRI Construction Materials Technologies (TST6049) 117T0004 TAS 110 2000 PRI Construction Materials Technologies (TST6049) 117T0005 UL 1897 2012 PRI Construction Materials Technologies (TST6049) 1085T0011 ASTM D 1623 2017 TAS 103 2020 UL LLC (TST1740) 02-NK40952 ASTM D 1970 2015a UL LLC (TST1740) 02-NK40952 ASTM D 226 2009 UL LLC (TST1740) 02-NK40952 ASTM D 2626 2004(2012)E1 �� UL LLC (TST1740) UL LLC (TST1740) 02-NK40952 02-NK40952 ASTM ASTM D 4869 D 6380Vwl 2016 1 ATL14001.7A FL17322-R7 a_gage 1 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEKi, ¢, Roofing Underlayments 9 TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION #15 Specification Felt ASTM D 226, Type I asphalt saturated organic felt underlayment for use in the HVHZ. #30 Organic Saturated Felt ASTM D 4869, Type II asphalt saturated organic felt underlayment for use in the non-HVHZ only. #30 Specification Felt ASTM D 226, Type 11 asphalt saturated organic felt underlayment for use in the HVHZ and non-HVHZ. #43 Base Sheet ASTM D 2626 asphalt saturated and coated, non -perforated, organic felt underlayment for use in the HVHZ and non-HVHZ. #90 Mineral Surface Roll ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the Roofing HVHZ and non-HVHZ. Gorilla Guard® EVERFELT 30 Asphalt -saturated organic felt underlayment reinforced with glass fiber that meets the performance requirements of ASTM D 226, Type I for use in the HVHZ. Slate/Tile Underlayment ASTM D 6380, Class M asphalt -saturated organic roll roofing sheet for use in the HVHZ and non-HVHZ. WeatherMaster0 Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 100 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster® Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 200 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster® Ice and ASTM D 1970 SBS modified, self -adhering underlayment reinforced with a Water 216 fiberglass mat and a granular surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film; which is removed during installation. WeatherMaster® Flexible Ice ASTM D 1970 SBS.modified, self -adhering underlayment with plastic film surface and Water for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a split -release film, which is removed during installation. WeatherMaster@ Pro -Grade ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Ice and Water Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self - adhering underlayment with a fiberglass mat reinforcement and a poly -fabric surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. WeatherMaster® Tile ASTM D 1970, TAS 103, and FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, Sixth Edition compliant compliant SBS modified, self - adhering underlayment with a fiberglass mat reinforcement and a poly -fabric -surface for use in the HVHZ and non-HVHZ. The self-adhesive side is covered with a release film, which is removed during installation. ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ATLAS ROOFING CORPORATION Roofing Underlayments APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the requirements below. Deck substrates shall be clean, dry, and _free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Exposure of the underlayments shall be limited to a maximum 30 days except as follows: a) #15 Specification Felt, #30 Specification Felt, and #40 Base Sheet — exposure for greater than 24 hours may adversely affect product performance b) WeatherMaster@) Ice and Water 100, WeatherMaster@ Ice and Water 200, WeatherMaster@ Ice and Water 216 — maximum 45 days c) WeatherMaster@ Pro -Grade Ice and Water —maximum 180 days d) WeatherMaster@ Tile —maximum 180 days Self -adhering •underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ. Roof coverings shall be mechanically fastened through the underlayment to the roof deck except as follows (or as indicated in other current FBC product approval documents): a) WeatherMaster@ Pro -Grade Ice and Water — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond b) WeatherMaster@ Tile — DAP Touch 'n Seal Storm Bond Roof Tile Adhesive or DuPont Tile Bond Allowable Roof Coverings: Composite Metal ;Roof or Wood Clay and Asphalt Panels and Photovoltaic Shingles Slate Concrete Underla ment Shingles Shingles Shingles and Shakes Shingles Tile #15 Specification Felt (HVHZ Y Y N Y2 Y N only) #30 Organic Saturated Felt Y Y Y Y Y N #30 Specification Felt Y Y Y Y Y Y #43 Base Sheet Y Y Y N Y Y #90 Mineral Surface Roll YI N N N N Y Roofing Gorilla Guard@ EVERFELT 30 Y Y Y Y2 Y N Slate/Tile Underlayment Y1 N N N N Y WeatherMaster@ Ice and Y Y Y N Y N Water 100 WeatherMaster@ Ice and Y Y Y N Y N Water 200 WeatherMaster@ Ice and Y Y Y N Y N Water 216 WeatherMaster@ Flexible Ice Y Y Y N Y N and Water WeatherMaster@ Pro -Grade Y Y Y N Y Y Ice and Water WeatherMaster(D Tile Y Y Y N Y Y Notes: 1) Open valley applications per 1507.2.9.2 2) Wood shingles only ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC WIND RESISTANCE (NON-HVHZ ONLY) ATLAS ROOFING CORPORATION Roofing Underlayments The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlayment System No.1 — WeatherMaster® Tile only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherMaster® Tile shall be fully adhered to the optionally primed plywood deck. Maximum Design -52.5 psf Pressure: Underlayment System No.2 — WeatherMaster® Pro -Grade Ice and Water only Roof Deck: Min. 15/32-inch APA plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherMaster® Pro -Grade Ice and Water shall be backnailed 12-inches o.c. to the plywood deck using min. 12ga, 1-1/4" galvanized, ring shank roofing nails with min. 32ga 1-5/8" diameter tin caps. Maximum Design -105 psf Pressure: LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) Roof slope limitations shall be in accordance with FBC requirements. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Products described within this report may be 'used as described in other current FBC product approval documents. 5) Roof coverings shall not be adhered directly to the underlayment unless otherwise approved in this or other current FBC product approval documents. 6) All products listed,in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. ATLAS ROOFING CORPORATION CREEKRoofing Underlayments TECH NICAL,SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. ,,,,1,,,,,,,,,,, PRY R. p \G E NSF No 74021 00 STATE OF A, +nn CERTIFICATION OF INDEPENDENCE 2020.10.16 14:18:26 u9+ah ao�,a er uavry z e,w, ry-04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. m END OF REPORT ATL14001.7A FL17322-R7 Page 4 of 6 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. T"EcHNICAL SERVICES, I. -.,LC EVALUATION REPORT Manufacturer: ATLAS ROOFING CORPORATION 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 (770)612-6267 Manufacturing Plants: Hampton, GA Meridian, MS Dangerfield, TX Ardmore, OK Franklin, OH Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 FLORIDA BUILDING CODE 7T" EDITION (2020) Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110) SCOPE Issued August 26, 2020 OCT 21 2021 i ST, Lucie County, Permitting Category: Roofing Subcategory: Asphalt Shingles Code Edition: Florida Building Code, 7`" Edition (2020) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance, Wind Driven Rain PRODUCT DESCRIPTION Legend (Ardmore) ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. GlassMaster®30 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, (Ardmore & Hampton) thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. Tough-Master020 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, (Ardmore & Hampton) thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro -Cut® Hip & Ridge ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle with a (Ardmore & Hampton) dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro -Cut® Starter Strip ASTM D 3161, Class F fiberglass reinforced, starter asphalt shingle with a dashed, (Hampton) thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. ProLAMTm Architectural ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated (Hampton, Franklin & architectural asphalt shingle with a dashed, thermally -activated, self-sealing sealant Meridian) stripe that complies with ASTM D 3462. Pinnacle® Pristine, ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated Pinnacle® Pristine architectural asphalt shingle with two, dashed, thermally -activated, self-sealing sealant Lifetime w/Scotchgard stripes that complies with ASTM D 3462. (Dangerfield, Hampton, Franklin & Meridian) StormMaster0 Shake ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated (Dangerfield) architectural modified asphalt shingle with two, dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. ATL13002.9 FL 16305-R9 Page-1 oNj This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacture hatif�iREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for v ort is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other produ a utes that are not specifically addressed herein. R ATLAS ROOFING CORPORATION _ Asphalt Shingles TECHNICAL SERVICES, LLC Storm Master® Slate ASTM D 3161, Class F & ASTM D 7158, Class H fiberglass reinforced, laminated (Ardmore) architectural modified asphalt shingle with two, dashed, thermally -activated, self-sealing sealant stripe that complies with ASTM D 3462. REFERENCES in!L Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL-079-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-083-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-086-02-01 Rev 1 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-104-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-106-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATLA 06-02-01 Rev 1 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATLA 07-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-107-02-01.1 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATLA 09-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATLA 16-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATLA 18-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATLA 19-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-123-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-125-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-127-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATLA 32-02-01 ASTM D 3161 2016 ' TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATLA 33-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATLA 35-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-136-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-137-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATLA 38-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-143-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-144-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-151-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-162-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-167-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies (TST5878) ATL-168-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-169-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-170-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-171-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-172-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-174-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-179-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-184-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-185-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATLA86-02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATLA 87-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-220-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-220-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-220-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-221-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-221-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-221-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-221-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-222-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-222-02-02 TAS 100 1995 ATL13002.9 FL 16305-R9 Page 2 of 11 This evaluation report is provided for State of Florida product -approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC ATLAS ROOFING CORPORATION Asphalt Shingles EU& Report No. Standard Year PRI Construction Materials Technologies (TST5878) ATL-222-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-222-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-223-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-223-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-223-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-223-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies (TST5878) ATL-224-02-01 ASTM D 3462 201 OA PRI Construction Materials Technologies (TST5878) ATL-225-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies (TST5878) ATL-225-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-225-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies (TST5878) ATL-225-02-04 ASTM D 7158 2019 CREEK Technical Services LLC (ANE11669) ATL13002.7 Calculations 2018 r- ATL13002.9 FL 16305-R9 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC INSTALLATION Legend Basic Wind Speed (V„ it): Basic Wind Speed (Vasa): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Solidly sheathed in accordance with FBC requirements. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 5-inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 5-inch exposure in- accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 1. Legend 4 Nail Pattern (Non-HVHZ only) Figure 2. Legend 6 Nail Pattern ATL13002.9 FL 16305-R9 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC GlassMaster® 30 & Basic Wind Speed (V„ it): Max. 194 mph Tough -Master® 20 Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 5-inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. 3T Figure 3. GlassMaster® 30 & Tough -Master® 20 4 Nail Pattern (Non-HVHZ only) ---- Nails 12" 5.51811 811 Figure 4. GlassMaster® 30 & Tough -Master® 20 6 Nail Pattern ATL13002.9 FL 16305-R9 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Prol-AMT"" Architectural Basic Wind Speed (V„ It): Basic Wind Speed (Vasd): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: , Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Solidly sheathed in accordance with FBC requirements. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. SINGLE Ya" SEALANT LINE PATTERN t LENGTH ON: 1 OFF 14•• % 1313' ._......................._..... ... ...__ .._..__..._........__ .....__._.....__..........1ryp __.._.._.............._._...__.......__....._......._...__....._-................_._... —................. ........... ..... ................ 1 I LI�.-ranwNG AREa I'.; :;:; • , , : ; : i P . • . : i 6B. i. 16 Figure 5. ProLAMTm Architectural Shingle 4 Nail Pattern (non-HVHZ only) 1 q" TYP _r.. ..... _....._..... _ �..—s'_._ f— I SINGLE X" SEALANT LINE PATTERN t LENGTH ON: 1 OFF - ............. .__ ....._...._ .. _... ......-- _._.. -- _...... _......-_ - ;j L1' NANNG AREA •i": •;., ••.,: •: •"^� l'; •".� ...� I Figure 6. Pro-LAMTm Architectural Shingle 6 Nail Pattern ATL13002.9 FL 16305-R9 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LL.0 Pinnacle® Pristine & Basic Wind Speed (Vint): StormMaster® Shake Basic Wind Speed (Vasd): Deck (HVHZ): Deck (Non-HVHZ) Underlayment: Min. slope: Installation (HVHZ) Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Solidly sheathed in accordance with FBC requirements. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. 4G ,DOUBLE Ya' SEALANT LINE PATTERN TOP: 1 LENGTH ON: 3 OFF BOTTOM: 1" LENCTH ON: 1" OFF 1318, 74" TYP 4 / � • 3 ......_I..1..�.............. _.........I.`.. .�I.........__..::........._.. X. .......,.................--..-....................................................................................................................... ......... IL 1,aNAIL NG AREA Figure 7. Pinnacle® Pristine and StormMaster® Shake 4 Nail Pattern (Non-HVHZ only) U DOUBLE X" SEALANT LINE PATTERN TOP: t LENGTH ON: 3 OFF BOTTOM: 1" LENGTH ON: 1" OFF 1 � 8 TYP 4.: " - -- '1' C------ ---_ . __.. 3...--- --- ------._.---- ---�- --- --------------........._-------------------------- ................... _..--------------------------- ------- ._ .... ®... ...... ..... Dom- __. ® I .._. �.__... ®._ ..... ®... ._. ®-.. ..._ ..... ®.... ..._ ... ®__ _. ..._ ®.... _. ..... . i` .... .. _.... 61, :. .... '....�': .. �.� NAgJYG Figure 8. Pinnacle® Pristine and StormMaster® Shake 6 Nail Pattern ATL13002.9 FL 16305-R9 I Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 14" CREEK TECHNICAL SERVICES, LLC StormMaster® Slate Basic Wind Speed (V,,,t): Basic Wind Speed (Vasd): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Solidly sheathed in accordance with FBC requirements. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed with 8.5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installed with 8.5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either "4 Nail Pattern" or "6 Nail Pattern" detailed below. Figure 9. StormMaster® Slate 4 Nail Pattern 1" T l Figure 10. StormMaster® Slate 6 Nail Pattern ATL13002.9 FL 16305-R9 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Pro -Cut® Starter Strip Basic Wind Speed (V it): Basic Wind Speed (Vasd) Deck (HVHZ): Deck (Non-HVHZ) Underlayment: Min. slope -- Installation (HVHZ): Installation (Non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Solidly sheathed in accordance with FBC requirements. In accordance with FBC requirements.' 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installed in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached as shown below. Installed in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached as shown below. 3e _ 1? ga. '_ 1/2" ring shank rail I 1 Figure 11. Pro -Cut® Starter Strip ATL13002.9 FL 16305-R9 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC Pro -Cut® Hip & Ridge Basic Wind Speed (V it): Basic Wind Speed (Vasa): Deck (HVHZ): Deck (Non-HVHZ): Underlayment: Min. slope: Installation (HVHZ and non-HVHZ): ATLAS ROOFING CORPORATION Asphalt Shingles Max. 194 mph Max. 150 mph In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Solidly sheathed in accordance with FBC requirements. In accordance with FBC requirements. 2:12 and in accordance with FBC requirements. Installed with 5-5/8 inch exposure in accordance with RAS 115 (HVHZ only) and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. 12" 1 12 ga. 1-1/2" ring shank nail 12" Ll �Ft Figure 12. Pro -Cut® Hip & Ridge ATL13002.9 FL 16305-R9 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC LIMITATIONS ATLAS ROOFING CORPORATION Asphalt Shingles 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC,' and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT 'The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. �`•`��G \>1 No 74021 �tr XZ :-0 .. 'STATE OF : 14/: n� CERTIFICATION OF INDEPENDENCE 2020.08.2 6 14:26:43 -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL13002.9 FL 16305-R9 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.