Loading...
HomeMy WebLinkAboutDBPR - Town Country Roll Up ShutterProfessional Regulation�� c �5•�_...misi�nrn�r Fvr�p�rch4r�rf:►:4�nrtrkrM��,smu�.l�.ri�a+cir� ;:. .. BCIS Home ! Log In I User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search b'p� 4,1 Product Approval r USER: Public User ✓7 duC[ Aanravai Menu.> PI'adud nr pkllratlnn Se Fdj > Appifration W > Application Detall FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email FL14235-R8 Revision 2020 Approved Town and Country Industries, 400 West McNab Road Ft. Lauderdale, FL 33309 (954)493-8551 tomj@tc-alum.com Tom Johnston tomj@tc-alum.com Category Shutters Subcategory Roll -up Compliance Method Fvaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer i ? Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Frank L. Bennardo, P.E. Evaluation Report Florida License PE-0046549 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By ORLANDO L. BLANCO, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) 5A nAaLd Year ASTM E1886 2002 ASTM E1886 2005 ASTM E1996 2012 ASTM E1996 2002 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL14235 R8 Enuly EQUIV123•pd Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/03/2021 Date Validated 02/05/2021 Date Pending FBC Approval 02/10/2021 Date Approved 04/13/2021 Products FL # Model, Number or Name 14235.1 Maestroshield Aluminum Roll -Up Shutter Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See installation instructions for span/design pressure schedules and other limitations of use. Description Aluminum roll -up shutter with non -end retention slats and rails. Installation Instructions FL14235 R6 'II i}WG1a.pdf FL14235 R8 II DWGIb.pdf Verified By: Frank L. Bennardo, P.E. PE0046549 Created by Independent Third Party: Yes Evaluation Reports FL14235 R8 AE EVAL1,pdf Created by Independent Third Party: Yes 14235.2 Eyewall Armor 44mm Aluminum Roll- Eyewall Armor 44mm Aluminum Roll -Up Shutter Up Shutter Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See installation instructions for span/design pressure schedules and other limitations of use. 14235.3 I Maestroshield Aluminum Roll -Up Shutter Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See installation instructions for span/design pressure schedules and other limitations of use. Installation Instructions FL14235 R8 II DWG2a.pdf FL14235 R8 II D.WG2b.pdf Verified By: Frank L. Bennardo, P.E. PE0046549 Created by Independent Third Party: Yes Evaluation Reports F114235 R8 AE EVAL2,pjdf FL14235 R8 AE FL14235 R3 AE BIII - UL - FCC 1.0-22-13 .(jQE - UL motors electronics)_pdf F-L14235 R8 AE FL14235 R3 AE Bill - UL - _FCC I0-22-13 (- V motor electronics)_pdf FL14235 R8 AE FL14235 R3,. AE Bill—UL - FCC 10-22-13.pdf FL1.4235. R8 AE FL14235 Charts.pdf FL14235 R8 AE FL14235 R3 AE UL cerl3ification standard motors.pdf Created by Independent Third Party: Yes Aluminum roll -up shutter with end retention and non -end retention slats and rails. Installation Instructions EL14235 R8 II I)WG3a.pdf FLL4235 R8 II OWG3b.pdf Verified By: Frank L. Bennardo, P.E. PE0046549 Created by Independent Third Party: Yes Evaluation Reports FLJ.4235 RS AE EVAL3.pdf FL14235 RS AE Bill - UL - FCC 10-22-13_(CE - UL motors electronics)_pdf FL14235 R8 AE Bill, -,UL - FCC 10-22-13 (!UV motor_ electronics)_pdf FL14235 R8 AE Bill - UL - ECC 10-22-.tpdf FL142, 5 R8 AE Lifting Charts.pdf FL14235 R5 AE SDI. certification standard motors. cp ff Created by Independent Third Party: Yes OR+IILSt Uj :: 20-01 9tajr-Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007_-2023 State of Florida, :: PrIVack Statement :: Accessibility Statement :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ANCHOR SCHEDULE: NON -END RETENTION WALL MOUNT ANCHOR SUBSTRATE MINIMUM EMBEDMENT MINIMUM EDGE MAXIMUM SPACING (O.C.) DISTANCE 1/4" DEWALT ULTRACON 2700 PSI MIN. CONCRETE 1.75" 2.5" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 2.5" 6.0" 1/4" ITW SS TAPCON 3192 PSI MIN. CONCRETE 1.75" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 2.5" 5.7" 5/16" DEWALT ULTRACON 3500 PSI MIN. CONCRETE 2.0" 3.125" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 3.125" 6.0" 5/16 ITW TAPCON 2899 PSI MIN. CONCRETE 2.25" 3.125" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 4.0" 6.0" HOLLOW CONCRETE BLOCK 1.75" 4.0" 6.0" 1/4" DEWALT POWER -BOLT 3000 PSI MIN. CONCRETE 2.5" 3.0" 6.0" GROUT -FILLED CONCRETE BLOCK 2.5" 5.25" 6.0" HOLLOW CONCRETE BLOCK 1.5" 12.0" 6.0" 1/4" ALL -POINTS SOLID -SET 3000 PSI MIN. CONCRETE 0.875" 3.0" 6.0" HOLLOW CONCRETE BLOCK 0.875" 3.0" 6.0" 1/4" LAG SCREW G=0.42 MIN. WOOD 1.5" 0.75" 6.0" #14 WOOD SCREW G=0.42 MIN. WOOD 1.5" 0.75" 6.0" #14 410 SS SMS (OR 1/4-20 410 SS THRU-BOLT) 1/8" THICK MIN. 6063-T6 ALUMINUM FULL THREAD PENETRATION 0.5" 6.0" 3/8" DEWALT SCREW BOLT 3000 PSI MIN. CONCRETE 3.5" 4.5" 6.0" GROUT -FILLED CONCRETE BLOCK* 2.5" 12.0" 6.0" 3/8" DEWALT CONFLEX 1819 PSI MIN. CONCRETE 3.5" 3.75" 6.0" 4510 PSI MIN. CONCRETE 3.5" 3.75" 6.0" 1/4" DEWALT CARBON STEEL OR 304 SS TAPPER 3000 PSI MIN. CONCRETE 1.75" 3.0" 6.0" HOLLOW CONCRETE BLOCK 1.25" 3.0" 5.3" ANCHOR SCHEDULE: NON -END RETENTION INTERIOR MOUNT ANCHOR SUBSTRATE MINIMUM EMBEDMENT MINIMUM EDGE MAXIMUM SPACING (O.C.) DISTANCE 1/4" DEWALT ULTRACON 2700 PSI MIN. CONCRETE 1.75" 2.5" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 2.5" 5.5" 1/4" ITW SS TAPCON 3192 PSI MIN. CONCRETE 1.75" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 2.5" 4.6" 5116" DEWALT ULTRACON 3500 PSI MIN. CONCRETE 2.0" 3.125" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 3.125" 6.0" 5/16 ITW TAPCON 2899 PSI MIN. CONCRETE 2.25" 3.125" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 4.0" 6.0" HOLLOW CONCRETE BLOCK 1.75" 4.0" 6.0" 1/4" DEWALT POWER -BOLT 3000 PSI MIN. CONCRETE 2.5" 3.0" 6.0" GROUT -FILLED CONCRETE BLOCK 2.5" 5.25" 6.0" HOLLOW CONCRETE BLOCK 1.5" 12.0" 6.0" 1/4" ALL -POINTS SOLID -SET 3000 PSI MIN. CONCRETE 0.875" 3.0" 6.0" HOLLOW CONCRETE BLOCK 0.875" 3.0" 6.0" 1/4" LAG SCREW G=0.42 MIN. WOOD 1.5" 0.75" 5.2" #14 WOOD SCREW G=0.42 MIN. WOOD 1.5" 0.75" 5.0" #14 410 SS SMS (OR 1/4-20 410 SS THRU-BOLT) 1/8" THICK MIN. 6063-T6 ALUMINUM FULL THREAD PENETRATION 0.5" 6.0" 3/8" DEWALT SCREW BOLT 3000 PSI MIN. CONCRETE 3.5" 4.5" 6.0" GROUT -FILLED CONCRETE BLOCK* 2.5" 12.0" 6.0" 3/8" DEWALT CONFLEX 1819 PSI MIN. CONCRETE 3.5" 3.75" 6.0" 4510 PSI MIN. CONCRETE 3.5" 3.75" 6.0" 1/4" DEWALT CARBON STEEL OR 304 SS TAPPER 3000 PSI MIN. CONCRETE 1.75" 3.0" 6.0" HOLLOW CONCRETE BLOCK 1.25" 3.0" 4.3" ANCHOR NOTES: 1. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 2. WHERE ANCHORS FASTEN TO NARROW FACE OF STUD FRAMING, ANCHOR SHALL BE LOCATED IN CENTER OF NOMINAL 2x (MIN) WOOD STUD (i.e. 3/4" EDGE DISTANCE IS ACCEPTABLE FOR ANCHORS TO WOOD FRAMING). 3. MINIMUM EMBEDMENT SHALL BE AS NOTED IN ANCHOR SCHEDULE. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES. 4. ANCHOR SCHEDULE APPLIES TO ALL PRODUCTS CERTIFIED HEREIN, BUT ONLY PROVIDES MAXIMUM ALLOWABLE ANCHOR SPACING. MAXIMUM ALLOWABLE SPANS AND PRESSURES INDICATED IN SPAN SCHEDULE SHALL APPLY. 5. WHERE EXISTING STRUCTURE IS WOOD FRAMING, EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT INTO PLYWOOD. 6. WOOD BUCKS (BY OTHERS) SHALL BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE EXISTING STRUCTURE. 7. MACHINE SCREWS SHALL HAVE MINIMUM OF 1/2" ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD ("SIDEWALK BOLT") U.N.O. 8. SHEET METAL SCREWS SHALL BE INSTALLED WITH FULL ENGAGEMENT OF THREADS INTO METAL HOST STRUCTURE. 9. ® DESIGNATES ANCHOR CONDITIONS WHICH ARE NOT ACCEPTABLE FOR USE. 10. * ANCHOR SHALL PENETRATE THROUGH FACE SHELL INTO GROUTED CELL. ANCHOR SCHEDULE: NON -END RETENTION BUILD -OUT MOUNT ANCHOR SUBSTRATE MINIMUM EMBEDMENT MINIMUM EDGE MAXIMUM SPACING (D.C.) DISTANCE 1/4" DEWALT ULTRACON 2700 PSI MIN. CONCRETE 1.75" 2.5" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 2.5" 1/4" ITW SS TAPCON 3192 PSI MIN. CONCRETE 1.75" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 2.5" 3.4" 5/16" DEWALT ULTRACON 3500 PSI MIN. CONCRETE 2.0" 3.125" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 2.5" 6.0" HOLLOW CONCRETE BLOCK 1.25" 3.125" 6.0" 5/16 ITW TAPCON 2899 PSI MIN. CONCRETE 2.25" 3.125" 6.0" GROUT -FILLED CONCRETE BLOCK 2.25" 4.0" 6.0" HOLLOW CONCRETE BLOCK 1.75" 4.0" 5.6" 1/4" DEWALT POWER -BOLT 3000 PSI MIN. CONCRETE 2.5" 3.0" 6.0" GROUT -FILLED CONCRETE BLOCK 2.5" 5.25" 6.0" HOLLOW CONCRETE BLOCK 1.5" 12.0" 6.0" 1/4" ALL -POINTS SOLID -SET 3000 PSI MIN. CONCRETE 0.875" 3.0" 6.0" HOLLOW CONCRETE BLOCK 0.875" 3.0" 6.0" 1/4" LAG SCREW G=0.42 MIN. WOOD 1.5" 0.75" 6.0" #14 WOOD SCREW G=0.42 MIN. WOOD 1.5" 0.75" 6.0" #14 410 SS SMS (OR 1/4-20 410 SS THRU-BOLT) 1/8" THICK MIN. 6063-T6 ALUMINUM FULL THREAD PENETRATION 0.5" 6.0" 3/8" DEWALT SCREW BOLT 3000 PSI MIN. CONCRETE 3.5" 4.5" 6.0" GROUT -FILLED CONCRETE BLOCK* 2.5" 12.0" 6.0" 3/8" DEWALT CONFLEX 1819 PSI MIN. CONCRETE 3.5" 3.75" 6.0" 4510 PSI MIN. CONCRETE 3.5" 3.75" 6.0" 1/4" DEWALT CARBON STEEL OR 304 SS TAPPER 3000 PSI MIN. CONCRETE 1.75" 3.0" 6.0" HOLLOW CONCRETE BLOCK 1.25" 3.0" FRANK BENNARDO,PE PE# 0046549 CA#9885 02rffL21 0 N Z OIt �It �r®^ FM�y0 V, W �--� J rn ui U rn U W LL� Mc Vm WLL aw ZO 2�w� wwU�X U� ~> LU -Z w Q w O W d t m o Z w1, ON u w W W ww 7 Z �LLoE(9 Ul vF w w O w tD p ui M N J u_ ujfs3 E y Q o O M �� 7 C 6 d' M Q -= w zm [0 J tL z w U Q �- :3 N K Wo O Q c[ O J V as LL N as a w H n o N IJ zo a � N 2 Q =mNm� oz C)IJLU LJL LL' 8-_ xS�WaW Z K J > > O Y w W U �30~ �g< Y w W � M (n m m LL LL m LL �- UJ COPYRIGHT FRANK L. BENNARDO P.E. 20-26180a SCALE: - PAGE DESCRIPTION: U HEADER LENGTH 82.1" MAX SLAT SPAN+82.1" MAX SLAT SPAN NON -END RETENTION SHUTTER WITH STORM BARS (DOUBLE -SPAN N.T.S. VCHOR 1LE FOR 'ACING NOTE: SEE ADDENDUM INSTALLATION INSTRUCTIONS FOR STORM BAR AND HEADER LIMITATIONS. )CTURAL JNTED 2T #30) ACED )M OF OR ITH E @16" EXTERIOR ELEV TABLE 3 NON -END RETENTION W/ INTERIOR & EXTERIOR STORM BARS SLAT SPAN ALLOWABLE DESIGN PRESSURE POSITIVE NEGATIVE 47.1" + 120.0 PSF 120.0 PSF 50.0" + 100.5 PSF 104.2 PSF 55.0" + 74.0 PSF 83.1 PSF 60.0" + 55.8 PSF 67.3 PSF 65.0" + 39.7 PSF 55.2 PSF 70.0" + 28.9 PSF 45.7 PSF 75.0" + 21.4 PSF 38.2 PSF 80.0" + 16.2 PSF 32.2 PSF 82.1" + 14.5 PSF 30.0 PSF HEADER LENGTH r- 82.1" MAX SLAT SPAN } 82.1" MAX SLAT SPAN n 82.1" MAX SLAT SPAN n NON -END RETENTION SHUTTER WITH STORM BARS (TRIPLE -SPAN N.T.S. Y r.\_7■=KEA 0 rtii i� • SLAT SPAN IS AS DEFINED IN DETAILS 1/6 AND 2/6. • LINEAR INTERPOLATION BETWEEN SHUTTER SPANS IS NOT PERMITTED. FOR SPANS BETWEEN THOSE INDICATED ABOVE, THE DESIGN PRESSURES FOR THE NEXT HIGHER SPAN SHALL BE USED. EXTERIOR ELEV FRANK BENNARDO,PE PE# 0046549 CA#9885 IF--3 02,/0i 21 O N ZO� _ E �M,yo V^ w�uiU UJ1 LLWc' LoWW LLn w ZOWoa wMCwaWUS7 F> a W W U' o ZkEL t coo z K N 0 �0Lu 0 J M z w H JCHOR LL. a 1LE FOR z w F w 'ACING O w VN c� 78 8 p'a s )CTURAL JNTED Q 2T #30) q, -ACED iM OF N v ITH OR z_@ 16" 5" \X C) a� O M d' M [0 _j a LL z LLI U �a W0 W W W 0 o v LL w H L2 �! o N oy-- a tc G 2 com Z U LL U LL r z- �k > Z p'wi: Z Z i�m x5=? O Y Df Df U �oo , Y w In m m LL LL m LL I In - m COPYRIGHT FRANK L. BENNARDO P.E. 20-26180a ALUMINUM STORM BARSL HEADERS AND MULLIONS ADDENDUM INSTALLATION INSTRUCTIONS FOR ROLL —UP SHUTTER HEADER LENGTH ROLL -UP SHUTTER SYSTEM PER THIS APPROVAL HEADER O 0 O O 0 0 O O 0 0 O O 0 0 O 0 • �v SLAT SPAN I SLAT SPAN 1 TYPICAL SHUTTER WITH STORM BARS 1 N.T.S. EXTERIOR ELEV GENERAL NOTES 1. THE SYSTEM DESCRIBED HEREIN HAS BEEN DESIGNED AND TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE SEVENTH EDITION (2020), THE INTERNATIONAL BUILDING CODE (IBC) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC), FOR USE WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. CRITICAL STORM BARS, MULLIONS AND HEADERS SHOWN HEREIN HAVE BEEN IMPACTED TO VERIFY LARGE MISSILE IMPACT RESISTANCE. SEE PRODUCT EVALUATION REPORT FOR ADDITIONAL INFORMATION. 2. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 3. POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED PER SEPARATE ENGINEERING IN ACCORDANCE WITH THE GOVERNING CODE. PRESSURE REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH ASCE 7 AND CHAPTER 1609 OF THE FLORIDA BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PRESSURE CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. 4. DESIGN PRESSURES NOTED HEREIN ARE BASED ON MAXIMUM TESTED PRESSURES DIVIDED BY A 1.5 SAFETY FACTOR. 5. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. THIS CERTIFICATION IS VALID FOR USE IN CONJUNCTION WITH THE MOST CURRENT REVISION OF FLORIDA PRODUCT APPROVAL #FL14235.1, MAESTROSHIELD ALUMINUM ROLL -UP SHUTTER. 6. PERMIT HOLDER SHALL VERIFY THE ADEQUACY OF THE EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS. 7. ALL EXTRUSIONS SHALL BE MINIMUM 6063-T5 ALUMINUM ALLOY, UNLESS NOTED OTHERWISE. 8. END CONNECTION DETAILS SHOWN MAY BE INTERCHANGED AS FIELD CONDITIONS DICTATE. 9. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 10. UNLESS OTHERWISE NOTED, ALL BOLTS & WASHERS SHALL BE ZINC COATED STEEL, GALVANIZED STEEL, OR STAINLESS STEEL WITH A MINIMUM TENSILE YIELD STRENGTH OF 60 KSI. 11. ALL STEEL IN CONTACT WITH ALUMINUM SHALL BE PAINTED OR PLATED AS PRESCRIBED IN THE FLORIDA BUILDING CODE. ROLL -UP SHUTTER SYSTEM PERT IS 'E OND SLAT SPAN SLAT SPAN TYPICAL SHUTTER WITH MULLIONS N.T.S. EXTERIOR ELEV VISIT ECALC.10/26180b FOR SITE SPECIFIC DEVIATIONS & MORE INFORMATION ABOUT THIS DOCUMENT OR SCAN THIS OR CODE VISIT ENGINEERINGEXPRESS.COMISTORE FOR ADDITIONAL PLANS, REPORTS & RESOURCES FRANK BENNARDO,PE PE# 0046549 CA#9885 III 02,/01 f 2021 t0 N Z O� ED w � Ja: In � ui , N U u W Iul W Maul ZW O owK H LU � U Z k aco 41 cz Lu 0 _j z w v �LL°�az U) w w W O vi M N ._j J LL N 4s *wwl w a a o rn O M -C O M ^ ❑ 3 � m -i a LL Vmx U - U K LU og m w wvu��o N Q W r N p N O O N - v v oo co - =m�mz U U - Z - Z Z _ 00 p Y Of w U �a Y w ��mmm - W o rv�o S� z 2 1 1 - COPYRIGHT FRANK L. BENNARDO RE, 20-26180b i OF g �8" MAX. X 0.125" MIN. L 0.250" MAX. 1-13 ALUMINUM TUBE 6" = V-0" MAT'L PER BOM N Z X 0.125" 1' 2.75" MIN. 5.75" MAX. Fy = 30 ksi MINIMUM STEEL REINFORCEMENT 141'-0" A36 GALV. STEEL OR STAINLESS STEEL Z X .. Q �M 0.250" 2" MIN. 4" MAX. 15 ALUMINUM ANGLE 6" = V-0" 6061-T6 OR 6005-T5 ALUM BILL OF MATERIALS ITEM # DESCRIPTION MATERIAL 1 2"x4"xO.125" TUBE 6063-T6 ALUM 2 2"x6x0.125" TUBE 6063-T6 ALUM 3 2"x3"xO.25" TUBE 6061-T6 OR 6005-T5 ALUM 4 2"x4"xO.25" TUBE 6061-T6 OR 6005-T5 ALUM 5 2"x6x0.25" TUBE 6061-T6 OR 6005-T5 ALUM 6 2"x6x0.125" TUBE 6063-T6 ALUM 7 2"x6x0.25" TUBE 6061-T6 OR 6005-T5 ALUM 8 3"xTW.125" TUBE 6063-T6 ALUM 9 3"x3"xO.25" TUBE 6061-T6 OR 6005-T5 ALUM 10 4"x4"xO.125" TUBE 6063-T6 ALUM 11 4"x4"x0.25" TUBE 6061-T6 OR 6005-T5 ALUM 12 4"x6x0.25" TUBE 6061-T6 OR 6005-T5 ALUM 13 4"x8"x0.25" TUBE 6061-T6 OR 6005-T5 ALUM 14 STEEL REINFORCEMENT F = 30 ksi MIN. A36 OR STAINLESS STEEL 15 ALUMINUM ANGLE 6061-T6 OR 6005-T5 ALUM STEEL REINFORCEMENT, 90% OF THE MULLION LENGTH, MINIMUM. LOCATED AT CENTER OF MULLION. MULLION #14 18-8 SS OR COATED SAE GR. 5 SMS OR SDS AT 12" O.C. MAX STAGGERED FOR FULL LENGTH OF REINFORCEMENT i TYPICAL REINFORCEMENT 2 N.T.S. SECTION END MULLION PER MULLION SCHEDULE -------------------------- .-------------------------- POLL UP SHUTTER AND ATTACHMENT TO MULLION PER ADDITIONAL INSTALLATION INSTRUCTIONS INCLUDED IN THIS APPROVAL 2 TYPICAL END MULLION 2 N.T.S. HORIZ SECTION INTERMEDIATE MULLION PER MULLION SCHEDULE -------------- ____________i LLy ii3i------____'______________ `--------------------------' L--------------------------i ROLL UP SHUTTER AND ATTACHMENT TO MULLION PER ADDITIONAL INSTALLATION INSTRUCTIONS INCLUDED IN THIS APPROVAL TYPICAL 3 INTERMEDIATE MULLION 2 N.T.S. HORIZ SECTION STORM BAR PER STORM BAR SCHEDULE STORM BAR PER STORM BAR SCHEDULE ROLL UP SHUTTERS PER THIS APPROVAL 4 TYPICAL STORM BARS 2 N.T.S. HORIZ SECTION FRANK BENNARDO,PE PE# 0046549 CA#9885 02, %621 N Z O� I �r�^ F- y0 ED W �--� J ui U r^ U L W NJ LL (n r�� In ZLu rQ 0 =2Wa wWU�C7x U� F> Q Zw �Q W oWU' o.r w Zk 0 _j zw z � LL 2: (n W w O W O M a m Q = w Ep J �ZmA zLL w U m � Q WW � o Q og w � tz w � "' � o � N Q u� 00 N p N O O N - 7 2 m � m � U LL U LL - � J z z m - p LL�o �a zap_ a�mmm � LL LL LL w COPYRIGHT FRANK L. BE MARDO P E. 20-26180b 0 STORM BAR AND MULLION SCHEDULE: 2"x6"x1/8" WITH 1.75"x5.75"x0.125" STEEL REINFORCEMENT* MEMBER LENGTH SLAT SPAN 25" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 30" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 35" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 40" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 45" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 50" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 55" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 60" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 65" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 70" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 75" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 80" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 120" 120.0 1250.0 120.0 1500.0 115.0 1676.7 100.6 1676.7 89.4 1676.7 80.5 1676.7 73.2 1676.7 67.1 1676.7 55.2 1495.0 45.7 1332.9 38.2 1193.8 32.2 1073.3 108" 120.0 1125.0 120.0 1350.0 120.0 1575.0 120.0 1800.0 114.6 1934.0 103.1 1934.0 83.1 1713.9 67.3 1514.3 55.2 1345.5 45.7 1199.6 38.2 1074.4 32.2 966.0 96" 120.0 1000.0 120.0 1200.0 120.0 1400.0 120.0 1600.0 120.0 1800.0 104.2 1736.7 83.1 1523.5 67.3 1346.0 55.2 1196.0 45.7 1066.3 38.2 955.0 32.2 858.7 84" 120.0 875.0 120.0 1050.0 120.0 1225.0 120.0 1400.0 120.0 1575.0 104.2 1519.6 83.1 1333.1 67.3 1177.8 55.2 1046.5 45.7 933.0 38.2 835.6 32.2 751.3 72" 120.0 750.0 120.0 900.0 120.0 1050.0 120.0 1200.0 120.0 1350.0 104.2 1302.5 83.1 1142.6 67.3 1009.5 55.2 897.0 45.7 799.8 38.2 716.3 32.2 644.0 60" 120.0 625.0 120.0 750.0 120.0 875.0 120.0 1000.0 120.0 1125.0 104.2 1085.4 83.1 952.2 67.3 841.3 55.2 747.5 45.7 666.5 38.2 596.9 32.2 536.7 48" 120.0 500.0 120.0 600.0 120.0 700.0 120.0 800.0 120.0 900.0 104.2 868.3 83.1 761.8 67.3 673.0 55.2 598.0 45.7-1-533.2 38.2 477.5 32.2 429.3 STORM BAR AND MULLION SCHEDULE: 3"x3"x1/8" WITH 2.75"x2.75"x0.125" STEEL REINFORCEMENT* MEMBER LENGTH SLAT SPAN 25" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 30" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 35" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 40" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 45" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 50" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 55" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 60" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 65" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 70" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 75" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 80" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 120" 64.2 668.4 53.5 668.4 45.8 668.4 40.1 668.4 35.6 668.4 32.1 668.4 1 29.2 668.4 26.7 668.4 24.7 668.4 22.9 668.4 21.4 668.4 20.1 668.4 108" 88.0 825.2 73.3 825.2 62.9 825.2 55.0 825.2 48.9 825.2 44.0 825.2 40.0 825.2 36.7 825.2 33.9 825.2 31.4 825.2 29.3 825.2 27.5 825.2 96" 120.0 1000.0 104.4 1044.4 89.5 1044.4 78.3 1044.4 69.6 1044.4 62.7 1044.4 57.0 1044.4 52.2 1044.4 48.2 1044.4 44.8 1044.4 38.2 955.0 32.2 858.7 84" 120.0 875.0 120.0 1050.0 120.0 1225.0 116.9 1364.1 103.9 1364.1 93.5 1364.1 83.1 1333.1 67.3 1177.8 55.2 1046.5 45.7 933.0 38.2 835.6 32.2 751.3 72" 120.0 750.0 120.0 900.0 120.0 1050.0 120.0 1200.0 120.0 1350.0 104.2 1302.5 83.1 1142.6 67.3 1009.5 55.2 897.0 45.7 799.8 38.2 716.3 32.2 644.0 60" 120.0 625.0 120.0 750.0 120.0 875.0 120.0 1000.0 120.0 1125.0 104.2 1085.4 83.1 952.2 67.3 841.3 55.2 747.5 45.7 666.5 38.2 596.9 32.2 536.7 48" 120.0 500.0 120.0 600.0 120.0 700.0 1 120.0 800.0 120.0 1 900.0 1 104.2 1 868.3 83.1 761.8 67.3 1 673.0 1 55.2 598.0 1 45.7 533.2 38.2 1 477.5 32.2 429.3 STORM BAR AND MULLION SCHEDULE: 4"x4"x1/8" WITH 3.75"x3.75"x0.125" STEEL REINFORCEMENT* MEMBER LENGTH SLAT SPAN 25" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 30" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 35" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 40" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 45" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 50" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 55" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 60" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 65" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 70" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 75" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 80" DESIGN REACTION PRESSURE AT ENDS (PSF) (LBS) 120" 120.0 1250.0 120.0 1500.0 115.4 1682.8 101.0 1682.8 89.7 1682.8 80.8 1682.8 73.4 1682.8 67.3 1682.5 55.2 1495.0 45.7 1332.9 38.2 1193.8 32.2 1073.3 108" 120.0 1125.0 120.0 1350.0 120.0 1575.0 120.0 1800.0 120.0 2025.0 104.2 1953.8 83.1 1713.9 67.3 1514.3 55.2 1345.5 45.7 1199.6 38.2 1074.4 32.2 966.0 96" 120.0 1000.0 120.0 1200.0 120.0 1400.0 120.0 1600.0 120.0 1800.0 104.2 1736.7 83.1 1523.5 67.3 1346.0 55.2 1196.0 45.7 1066.3 38.2 955.0 32.2 858.7 84" 120.0 875.0 120.0 1050.0 120.0 1225.0 120.0 1400.0 120.0 1575.0 104.2 1519.6 83.1 1333.1 67.3 1177.8 55.2 1046.5 45.7 933.0 38.2 835.6 32.2 751.3 72" 120.0 750.0 120.0 900.0 120.0 1050.0 120.0 1200.0 120.0 1350.0 104.2 1302.5 83.1 1142.6 67.3 1009.5 55.2 897.0 45.7 799.8 38.2 716.3 32.2 644.0 60" 120.0 625.0 120.0 750.0 120.0 875.0 120.0 1000.0 120.0 1125.0 104.2 1085.4 83.1 952.2 67.3 841.3 55.2 747.5 45.7 666.5 38.2 596.9 32.2 536.7 48" 1120.0 500.0 120.0 1 600.0 1 120.0 1 700.0 120.0 800.0 120.0 1 900.0 1 104.2 1 868.3 83.1 761.8 67.3 1 673.0 1 55.2 1 598.0 45.7 533.2 38.2 477.5 32.2 429.3 STORM BAR AND MULLION SCHEDULE NOTES: 1. PRESSURES SHOWN IN "STORM BAR AND MULLION SCHEDULE" ARE MAXIMUM ALLOWABLE POSITIVE AND NEGATIVE DESIGN PRESSURES AT EACH RESPECTIVE SLAT SPAN AND STORM BAR/MULLION HEIGHT. DESIGN VALUES NOTED HEREIN WHEN USED WITH MULLIONS SHALL ONLY BE USED WITH NON -END RETENTION ROLL -UP SHUTTERS. 2. "STORM BAR AND MULLION SCHEDULES" ARE APPLICABLE TO ALL STORM BARS AND NON -END RETENTION MULLIONS. 3. SEE SHEET 2 FOR STORM BAR, MULLION, AND REINFORCEMENT DETAIL AND MATERIALS. 4. FOR END MULLIONS, ONE HALF OF THE SLAT SPAN MAYBE USED TO DETERMINE ALLOWABLE DESIGN PRESSURES AND END REACTIONS. END MULLIONS ARE AS DEFINED IN ELEVATION 2/1. *NOTE: STEEL REINFORCEMENT LENGTH 5. ALLOWABLE DESIGN PRESSURES AND SLAT SPANS INDICATED ARE FOR DETERMINING SHALL BE A MINIMUM OF 90% THE MULLION PERMISSIBLE STORM BAR AND MULLION HEIGHTS ONLY. ACTUAL SLAT SPANS AND DESIGN PRESSURES LENGTH, LOCATED AT THE CENTER OF THE SHALL NOT EXCEED THOSE INDICATED IN SEPARATE ROLL -UP SHUTTER APPROVAL. "REACTION MULLION AND FASTENED IN PLACE WITH 6. AT ENDS" IS LISTED FOR EACH COMBINATION OF DESIGN LOAD, STORM #14 18-8 SS OR COATED SAE GR. 5 STEEL BAR/MULLION TYPE, & SLAT SPAN. CHOOSE MOUNTING CONNECTIONS (PER APPLICABLE CONNECTION SMS OR SDS AT 12" O.C. MAX STAGGERED DETAILS HEREIN) THAT PROVIDES "CONNECTION CAPACITY" GREATER THAN OR EQUAL TO "REACTION ALONG THE FULL REINFORCEMENT LENGTH. AT ENDS" GIVEN ABOVE. (REFERENCE STEEL REINFORCEMENT DETAIL 7. THIS SCHEDULE MAY BE USED FOR ALL MOUNTING CONDITIONS LISTED HEREIN. 8. ® DENOTES CONDITIONS NOT APPROVED FOR USE. 1/2) FRANK BENNARDO, PE PE# 0046549 CA#9885 02VftL21 U to N Z OIt . I _ It 0 �F_Q� _vM"O yz� 0r^HMrnV)u MU Zi Jw� ui LL K JW LL QZwwUSXx> Qw woWU It 'co902Z�W�,1ww LLW w Ow %D p Lri M N v J LL. w� �0 O M oa ° K M zm A m a LL z LLi a U CG Q �V- K � w w D og Q w c H o N zJ�o p v v ro co - ao =mU) U LL U� K o 0' J > > [t] 3�- p `L Ir w U x' < wM w�w ww� �mm (n m LL LL LL oa ¢�o COPYRIGHT FRANK L. BENNARDO P.E. 20-26180b SCALE: - PAGE DESCRIPTION: m OF I FRANK BENNARDO,PE PE# 0046549 CA#9885 HEADER SCHEDULE: 2"x6"x1/8" WITH 1.75"x5.75"x0.125" STEEL REINFORCEMENT* HEADER LENGTH STORM BAR HEIGHT 60" 76" 92" 108" 124" 140" 156" 172" 188" 204" 220" 228" DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION DESIGN REACTION PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS PRESSURE AT ENDS (PSF) (LBS) IPSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) (PSF) (LBS) 120" 120.0 1000.0 105.9 1117.5 87.5 1117.5 74.5 1117.5 64.9 1117.5 57.5 1117.5 51.6 1117.5 46.8 1117.5 42.8 1117.5 39.4 1117.5 36.6 1117.5 35.3 1117.5 108" 120.0 900.0 120.0 1140.0 112.1 1289.4 95.5 1289.4 83.2 1289.4 73.7 1289.4 66.1 1289.4 60.0 1289.4 54.9 1289.4 50.6 1289.4 46.9 1289.4 45.2 1289.4 96" 120.0 800.0 120.0 1013.3 120.0 1226.7 120.0 1440.0 110.3 1519.8 97.7 1519.8 87.7 1519.8 79.5 1519.8 72.8 1519.8 67.0 1519.8 62.2 1519.8 60.0 1519.8 84" 120.0 700.0 120.0 886.7 120.0 1073.3 120.0 1260.0 120.0 1446.7 120.0 1633.3 120.0 1820.0 110.3 1844.9 100.9 1844.9 93.0 1844.9 86.3 1844.9 83.2 1844.9 72" 120.0 600.0 120.0 760.0 120.0 920.0 120.0 1080.0 120.0 1240.0 120.0 1400.0 120.0 1560.0 120.0 1720.0 120.0 1880.0 120.0 2040.0 120.0 2200.0 120.0 2280.0 60" 120.0 500.0 120.0 633.3 120.0 766.7 120.0 900.0 120.0 1033.3 120.0 1166.7 120.0 1300.0 120.0 1433.3 120.0 1566.7 120.0 1700.0 120.0 1833.3 120.0 1900.0 48" 120.0 400.0 120.0 506.7 120.0 613.3 120.0 720.0 120.0 826.7 120.0 933.3 120.0 1040.0 120.0 1146.7 120.0 1253.3 120.0 1360.0 120.0 1466.7 120.0 1520.0 36" 120.0 300.0 120.0 380.0 120.0 460.0 120.0 540.0 120.0 620.0 120.0 700.0 120.0 780.0 120.0 860.0 120.0 940.0 120.0 1020.0 120.0 1100.0 120.0 1140.0 HEADER SCHEDULE NOTES: 1. PRESSURES SHOWN IN "HEADER SCHEDULE" ARE MAXIMUM ALLOWABLE POSITIVE AND NEGATIVE DESIGN PRESSURES AT EACH RESPECTIVE HEADER LENGTH AND STORM BAR HEIGHT. DESIGN PRESSURES ARE APPLICABLE TO BOTH DOUBLE -SPAN AND TRIPLE -SPAN CONDITIONS. 2. "HEADER SCHEDULES" ARE APPLICABLE TO ALL HEADERS. 3. SEE SHEET 2 FOR HEADER AND REINFORCEMENT DETAIL AND MATERIALS. 4. ALLOWABLE DESIGN PRESSURES AND STORM BAR HEIGHTS INDICATED ARE FOR DETERMINING PERMISSIBLE HEADER LENGTHS ONLY. ACTUAL STORM BAR HEIGHT AND DESIGN PRESSURES SHALL NOT EXCEED THOSE INDICATED IN "STORM BAR AND MULLION SCHEDULES" AS APPLICABLE. 5. "REACTION AT ENDS" IS LISTED FOR EACH COMBINATION OF DESIGN LOAD, HEADER LENGTH, & STORM BAR HEIGHT. CHOOSE MOUNTING CONNECTIONS (PER APPLICABLE CONNECTION DETAILS HEREIN) THAT PROVIDES "CONNECTION CAPACITY" GREATER THAN OR EQUAL TO "REACTION AT ENDS" GIVEN ABOVE. 6. THIS SCHEDULE MAY BE USED FOR ALL MOUNTING CONDITIONS LISTED HEREIN. 7. ® DENOTES CONDITIONS NOT APPROVED FOR USE. *NOTE: STEEL REINFORCEMENT LENGTH SHALL BE A MINIMUM OF 90% THE MULLION LENGTH, LOCATED AT THE CENTER OF THE MULLION AND FASTENED IN PLACE WITH #14 18-8 SS OR COATED SAE GR. 5 STEEL SMS OR SIDS AT 12" O.C. MAX STAGGERED ALONG THE FULL REINFORCEMENT LENGTH. (REFERENCE STEEL REINFORCEMENT DETAIL 1/2) STORM BAR TO HEADER CONNECTION DETAILS (3) #14 410 SS OR COATED SAE GR. 5 STEEL SMS OR SIDS PER ANGLE Y" MIN. FROM ANY ALUPIII�UM EDGE, HEADER PER SPACED %" O.C. MIN. HEADER SCHEDULE --\ (2) 5/6" 18-8 SS OR COATED SAE GR. 5 STEEL THRU-BOLTS, WITH Y4" MIN. EDGE DISTANCE FROM ANY ALUMINUM EDGE. STORM BAR PER STORM BAR AND MULLION SCHEDULE CONNECTION CAPACITY: 4262 LB i STORM BAR TO HEADER 12 N.T.S. VERT SECTION (6) #14 410 SS OR COATED SAE GR. 5 STEEL SMS OR HEADER PER SIDS PER ANGLE, %2" MIN. HEADER FROM ANY ALUMINUM EDGE, SCHEDULE, PACED %" O.C. MIN. (3) 3/8" 18-8 SS OR COATED SAE GR. 5 I� STEEL THRU-BOLTS, WITH Y4" MIN. EDGE DISTANCE FROM ANY ALUMINUM EDGE. (2) ANGLES PER 2 MIN.�MIN.y 15 STORM BAR ONE EACH SIDE OF I I STORM BAR STORM BAR PER I I STORM BAR AND MULLION SCHEDULE CONNECTION CAPACITY: 8524 LB 2 STORM BAR TO HEADER 12 N.T.S. VERT SECTION HEADER PER HEADER SCHEDULE MIN. MIN. MIN. MIN. r MIN. MIN: (3) 3/8" 18-8 SS OR COATED SAE GR. 5 STEEL THRU-BOLTS, WITH Y4" MIN. EDGE DISTANCE FROM ANY ALUMINUM EDGE. o2y�i.Y�2i U 0 N It Z o1 �ro^ F_ y0 ED WH J �uiU r^ ULr) W - 0 LL (n r�� In W w aw Z O Lu u20a- ''nnn w-> x U� F> Q Zw �QwoWU' Zk d m o W. 0 � zw �� � LL 2: �1w <W w � t7 Ln M N I V(6) #14 410 SS OR COATED SAE GR. 5 STEEL SMS OR SIDS PER ANGLE 1/" MIN. FROM ANY ALUMINUM EDGE, SPACED %" O.C. MIN STORM BAR PER STORM BAR AND MULLION SCHEDULE CONNECTION CAPACITY: 8524 LB 3 STORM BAR TO HEADER 12 N.T.S. VERT SECTION vl�n r�+w 38 rr � � �1 l+�r- ate � °ate O M a m CA:) mh z � W U m � Q W w Q og w � Q w ;! u, �: o N -- Q tc p N O O N - vvaoco - =mU) U LL U 1 - Z Z Z �wzzm m� p Y w w U LL�o �a zap_ Q (n m m m � LL LL LL w V Z O COPYRIGHT FRANK L. BE MARDO P E. 20-26180b OF I STORM BAR AND MULLION CONNECTION DETAILS MIN. SPACING PER SCHEDULE 'Al' (2) ANCHORS PER SCHEDULE 'Al' 3/4" MIN, TYPICAL (2) 516" 18-8 SS OR COATED SAE GR. 5 STEEL THRU-BOLTS, WITH STORM BAR OR MULLION PER STORM BAR 3/4" MIN. EDGE DISTANCE FROM AND MULLION SCHEDULES. ORIENTATION ANY ALUMINUM EDGE. VARIES FOR INTERIOR OR WALL MOUNT, SEE DETAIL 4/13. END CONNECTION 1 INTERIOR OR WALL MOUNT 1 3 N.T.S. 15 � Q Z w U J Q a w N 2 Z_ U Ln w a (4) ANCHORS PER MIN. SPACING SCHEDULE 'Al' PER SCHEDULE 'Aft, -1-1 3/4" MIN, TYPICAL 3/4" MIN, 3/4" MIN, TYPICAL 3/4" MIN, TYPICAL s /s (3) �� 18-8 SS OR COATED SAE STORM BAR OR MULLION PER STORM GR. 5 STEEL THRU-BOLTS, WITH BAR AND MULLION SCHEDULES. 3/4" MIN. EDGE DISTANCE FROM ORIENTATION VARIES FOR INTERIOR ANY ALUMINUM EDGE. OR WALL MOUNT, SEE DETAIL 4/13. END CONNECTION 2 INTERIOR OR WALL MOUNT 1 3 N.T.S. ANCHOR NOTES: 1. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. 2. MINIMUM EMBEDMENT SHALL BE AS NOTED IN ANCHOR SCHEDULE. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDES STUCCO, FOAM, BRICK, AND OTHER WALL FINISHES. 3. ANCHOR SCHEDULE APPLIES TO ALL PRODUCTS CERTIFIED HEREIN. 4. WHERE EXISTING STRUCTURE IS WOOD FRAMING, EXISTING CONDITIONS MAY VARY. FIELD VERIFY THAT FASTENERS ARE INTO ADEQUATE WOOD FRAMING MEMBERS, NOT INTO PLYWOOD. 5. MACHINE SCREWS SHALL HAVE MINIMUM OF 5/8" ENGAGEMENT OF THREADS IN BASE ANCHOR AND MAY HAVE EITHER A PAN HEAD, TRUSS HEAD, OR WAFER HEAD ("SIDEWALK BOLT") U.N.O. 6. ` ANCHOR SHALL PENETRATE THROUGH FACE SHELL INTO GROUTED CELL. (2) A" 18-8 SS OR COATED SAE GR. 5 STEEL THRU-BOLTS, WITH %2" MIN. EDGE DISTANCE FROM ANY ALUMINUM EDGE. 15 ONE EACH SIDE OF STORM BAR, TYPICAL • CLUSTER OF (4) 3/8" DEWALT SCREW BOLTS AT CENTERED EACH STORM BAR W/ 33/2" MIN. EMBED, 3" MIN. EDGE DISTANCE, AND 41/2" SPACING TO 3KSI MIN. CONCRETE. BALANCE SPACED AT 18" O.C. MAX • CLUSTER OF (4) 5/16" ITW TAPCONS AT CENTERED EACH STORM BAR W/ 2-1/4" MIN. EMBED/ 4" MIN. EDGE DISTANCE, AND 4' SPACING TO GROUT -FILLED CONCRETE BLOCK BALANCE SPACED AT 18" O.C. MAX • CLUSTER OF (4) 5/16" LAG SCREWS AT CENTERED EACH STORM BAR W/ 2" MIN. THREAD PENETRATION, 1-1/4" MIN. EDGE DISTANCE, AND 2" SPACING TO G=0.42 MIN. WOOD. BALANCE SPACED AT 18" O.C. MAX • SCHEDULE'Al' STORM BARS PER STORM BAR AND MULLION SCHEDULES 1" MIN 1" MIN. (2) Y4" 18-8 SS OR COATED SAE GR. 5 STEEL THRU-BOLTS, WITH 3/2" MIN. EDGE DISTANCE FROM ANY ALUMINUM EDGE. ONE EACH SIDE OF STORM BAR, TYPICAL 6063-T6 ALUMINUM BAR, 0.25" MIN. THICKNESS. SIZE VARIES PER STORM BAR SIZE �R1/5 STEEL THRU-B COATED SAE . 5 STEEL THRU-BOLTS PER 1� ANGLE W/ Y2" MIN EDGE DISTANCE (2) /4"-20 316 SS THRU-BOLTS PER q TO ANY ALUMINUM EDGE ANGLE W/ 1/2" MIN EDGE DISTANCE <TFP 15 TO ANY ALUMINUM EDGE NqT� — — — — — — — — — — — — — — — — — — — — — — — — (2) 20 SS O (2) #14 18-8 SS OR 1/2" 1/2" COATED SAE GR. 5 MIN. MIN. STEEL SMS OR SDS IPER ANGLE W/ %" MIN EDGE DISTAqCE TO 1/2" 1/2" ATED SAE GR. 5 STEEL 1 MIN. MIN.ITHRU-BOLTS PER ANGLE W/ 1" MIN.%" MIN EDGE DISTANCE TO AY ALUMINUM EDGE ANY ALUMINUM EDGE 6063-T6 ALUMINUM ANGLE, 0.25" MIN. THICKNESS. SIZE EQ. VARIES PER STORM BAR SIZE. CLUSTER OF (9) #14 18-8 SS OR COATED SAE GR. 5 STEEL i EQ. SMS OR SIDS CENTERED AT EACH STORM BAR W/ %" MINIMUM ANY /" THICK ALUMINUM EDGE DISTANCE TO ANY ALUMINUM EDGE (INCLUD2ING TUBE FR6M SHEETS 2 AND 3 ACCESS HOLES FOR WEDGE BOLTS, SPACED 3/4" O.C. MIN, 3" O.C. MAX. BALANCE SPACED AT 18' O.C. MAX — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ---- CONNECTION CAPACITY: 2276 LB 3 STORM BAR BUILD -OUT MOUNT 13 N.T.S. VERT SECTION ANCHOR TYPE MINIMUM SPACING MINIMUM EDGE DISTANCE CONNECTION DETAIL MOUNTING CONDITION CONNECTION CAPACITY 3/8" DEWALT SCREW BOLTS 1/13 WALL MOUNT 4332 LB INTERIOR MOUNT 3065 LB W/ 3-1/2" EMBED TO 3KSI MIN. CONCRETE 4.5" 4.5" 2/13 WALL MOUNT 8820 LB INTERIOR MOUNT 6130 LB 3/8" DEWALT STEEL DROPIN 1/13 WALL MOUNT 1590 LB INTERIOR MOUNT 2290 LB W/ 1-9/16" EMBED TO 3KSI MIN. CONCRETE 4.5" 5.25" 2/13 WALL MOUNT 3180 LB INTERIOR MOUNT 4580 LB 3/8" DEWALT SCREW BOLTS 1/13 WALL MOUNT 2580 LB INTERIOR MOUNT 2200 LB W/ 3-1/2" EMBED TO GROUT -FILLED CONCRETE BLOCK' 6.0" 12.0" 2/13 WALL MOUNT 5160 LB INTERIOR MOUNT 4400 LB 5/16" ITW TAPCON XL OR DEWALT ULTRACON W/ 2-1/4" MIN. EMBED TO 3.5KSI MIN. 5.0" 3.125" 1/13 WALL MOUNT 1576 LB INTERIOR MOUNT 1702 LB WALL MOUNT 3152 LB CONCRETE 2/13 INTERIOR MOUNT 3404 LB 5/16" ITW TAPCON XL OR DEWALT ULTRACON W/ 2-1/4" MIN. EMBED TO GROUT -FILLED 5.0" 3.125" 1/13 WALL MOUNT 584 LB INTERIOR MOUNT 744 LB WALL MOUNT 1168 LB CONCRETE BLOCK 2/13 INTERIOR MOUNT 1488 LB WALL MOUNT 1310 LB 5/16" LAG SCREW W/ 2" MIN. THREAD PENETRATION TO G=0.42 MIN WOOD 2.0" 1.25" 1/13 INTERIOR MOUNT 302 LB 2/13 WALL MOUNT 2620 LB INTERIOR MOUNT 604 LB THRU-BOLTS PER DETAILS ABOVE `STORM BAR OR MULLION PER STORM BAR AND O MULLION SCHEDULES. EXISTING HOST \\\\ STRUCTURE ANCHORSPER DETAILS ABOVE INTERIOR MOUNT ANCHORSPER DETAILS ABOVE J/11 EXISTING HOST %j/ STRUCTURE J THRU-BOLTS PER DETAILS ABOVE STORM BAR OR MULLION PER STORM BAR AND MULLION SCHEDULES. WALL MOUNT END CONNECTION 4 MOUNTING CONDITIONS 1 3 N.T.S. FRANK BENNARDO,PE PE# 0046549 CA#9885 III 02,/01/2021 N Z o� WuJ LL (n W m In W LL aw Z O u wW -Ex Ua~'<—w �QWoWU Zk 0Lm�z� 0 _j zw z � LL 2: (ncvFw O W j W Ln M N v LL w O M O � M Q = w p] J � mA z w w v can w Z m m L � 0 CONTINUOUSLY ANCHORED MULLION CONNECTION DETAILS ROLL -UP SHUTTER -E OND SLAT SPAN SLAT SPAN SHUTTER WITH MULLIONS 1 ANCHORED CONTINUOUSLY 14 N.T.S. EXTERIOR ELEV ANCHORS PER SCHEDULE 'A3' END MULLION PER MULLION SCHEDULE INTERMEDIATE MULLION PER MULLION SCHEDULE t_ ANCHORS PER SCHEDULE 'A3' ROLL UP SHUTTER AND ATTACHMENT TO ROLL UP SHUTTER AND ATTACHMENT TO MULLION PER ADDITIONAL INSTALLATION MULLION PER ADDITIONAL INSTALLATION INSTRUCTIONS INCLUDED IN THIS APPROVAL INSTRUCTIONS INCLUDED IN THIS APPROVAL END MULLION INTERMEDIATE MULLION 2 CONTINUOUSLY ANCHORED 3 CONTINUOUSLY ANCHORED 14 N.T.S. HORIZ SECTION 14 N.T.S. HORIZ SECTION SCHEDULE 'A2' SLAT SPAN DESIGN PRESSURE (PSF) REACTION ALONG LENGTH INTERMEDIATE END MULLION MULLION 40 50 LB/FT 100 LB/FT 60 75 LB/FT 150 LB/FT 30" 80 100 LB/FT 200 LB/FT 100 125 LB/FT 250 LB/FT 120 150 LB/FT 300 LB/FT 40 67 LB/FT 133 LB/FT 60 100 LB/FT 200 LB/FT 40" 80 133 LB/FT 267 LB/FT 100 167 LB/FT 333 LB/FT 120 200 LB/FT 400 LB/FT 40 83 LB/FT 167 LB/FT 60 125 LB/FT 250 LB/FT 50" 80 167 LB/FT 333 LB/FT 100 208 LB/FT 417 LB/FT 120 250 LB/FT 500 LB/FT 40 100 LB/FT 200 LB/FT 60 150 LB/FT 300 LB/FT 60" 80 200 LB/FT 400 LB/FT 100 250 LB/FT 500 LB/FT 120 300 LB/FT 600 LB/FT 40 117 LB/FT 233 LB/FT 60 175 LB/FT 350 LB/FT 70" 80 233 LB/FT 467 LB/FT 100 292 LB/FT 583 LB/FT 120 350 LB/FT 700 LB/FT 40 133 LB/FT 267 LB/FT 60 200 LB/FT 400 LB/FT 80" 80 267 LB/FT 533 LB/FT 100 333 LB/FT 667 LB/FT 120 400 LB/FT 800 LB/FT SCHEDULE 'AT ANCHOR TYPE MINIMUM EDGE DISTANCE ANCHOR SPACING (ON CONNECTION CAPACITY CENTER) 12" 2205 LB/FT 3/8" DEWALT SCREW BOLTS 18" 1470 LB/FT W/ 3-1/2" EMBED TO 3KSI MIN. CONCRETE 4.5" 24" 735 LB/FT 30" 294 LB/FT 12" 1290 LB/FT 3/8" DEWALT SCREW BOLTS 18" 860 LB/FT W/ 3-1/2" EMBED TO GROUT -FILLED CONCRETE BLOCK' 12.0" 24" 430 LB/FT 30" 172 LB/FT 12" 795 LB/FT 3/8" DEWALT STEEL DROPIN 18" 530 LB/FT W/ 1-9/16" EMBED TO 3KSI MIN. CONCRETE 5.25" 24" 265 LB/FT 30" 106 LB/FT 12" 788 LB/FT 5/16" ITW TAPCON XL OR DEWALT 18" 525 LB/FT ULTRACON W/ 2-1/4" MIN. EMBED TO 3.5KSI MIN. CONCRETE 4.0" 24" 263 LB/FT 30" 105 LB/FT 5/16" ITW TAPCON XL OR DEWALT 12" 292 LB/FT 18" 195 LB/FT ULTRACON W/ 2-1/4" MIN. EMBED TO GROUT -FILLED CONCRETE 3.125" 24" 97 LB/FT BLOCK 30" 39 LB/FT 12" 655 LB/FT 5/16" LAG SCREW W/ 2" MIN. THREAD PENETRATION TO G=0.42 MIN WOOD 1.25" 18" 437 LB/FT 24" 218 LB/FT 30" 87 LB/FT CONTINUOUSLY ANCHORED MULLION NOTES: 1. USE SCHEDULE 'A2' TO DETERMINE THE REACTION ALONG MULLION LENGTH FOR THE APPLICABLE SLAT SPAN AND DESIGN PRESSURE. 2. "REACTION ALONG LENGTH" IS LISTED FOR EACH COMBINATION OF DESIGN LOAD & SLAT SPAN. CHOOSE ANCHOR TYPE AND ANCHOR SPACING FROM SCHEDULE 'A3' THAT PROVIDES "CONNECTION CAPACITY" GREATER THAN OR EQUAL TO "REACTION ALONG LENGTH" GIVEN ABOVE IN SCHEDULE 'A2'. 3. SCHEDULES ARE APPLICABLE TO ALL NON -END RETENTION MULLIONS. 4. ALLOWABLE DESIGN PRESSURES AND SLAT SPANS INDICATED ARE FOR DETERMINING PERMISSIBLE MULLION ANCHORS ONLY. ACTUAL SLAT SPANS AND DESIGN PRESSURES SHALL NOT EXCEED THOSE INDICATED ROLL -UP SHUTTER INSTALLATION INSTRUCTIONS. 5. THIS SCHEDULE MAY BE USED FOR ALL NON -END RETENTION MULLIONS ANCHORED CONTINUOUSLY ALONG THEIR LENGTH. 6. SEE ANCHOR NOTES ON SHEET 13 FRANK BENNARDO,PE PE# 0046549 CA#9885 029621 w Hn ui �: o N m n O z - R o Z =m ;m� o U LL Z U LL x - G' J >Z > >Z > O Y x x U a wt Y w m m m w COPYRIGHT FRANK L. BENNARDO P E. 20-26180b ml OFF N FRANK BENNARDO,PE PE# 0046549 CA#9885 HEADER CONNECTION DETAILS ANCHOR PER SCHEDULE 'B' SHUTTER RAIL HEADER PER HEADER SCHEDULES BUILD -OUT & WALL MOUNT 1 5 N.T.S. ELEV ANCHOR PER SCHEDULE 'B' EXISTING HOST STRUCTURE HEADER HEAT SCHEDU 2 WALL MOUNT 15 N.T.S. HORIZ SECTION ANCHOR PER SCHEDULE 'B' EXISTING HOST STRUCTURE BUILD -OUT TUBE HEADER P HEAD SCHEDUL MIN. SPACING PER SCHEDULE 'B' (2) 3/8" 18-8 SS OR COATED SAE GR. 5 STEEL THRUBOLTS, %4" FROM ANY ALUMINUM EDGE, 1" MIN. SPACING. (2) ANCH( SCHE HEADER PER (2) 3/8" 18-8 SS OR COATED HEADER SAE GR. 5 STEELTHRUBOLTS, 3/4" HEADER PER SCHEDULES FROM ANY ALUMINUM EDGE, 1" [SCHEDULES HEADER MIN. SPACING. BUILD -OUT & 4 WALL MOUNT 15 N.T.S. ELEV (2) ANCHORS PER SCHEDULE 'B' 3/4" IN. 1" MIN. 3/4" MIN. HEADER PER HEADER SCHEDULES MIN. SPACING PER EMBED. 15 SCHEDULE 'B' / (2) 3/8" 18-8 SS OR COATED SAE GR. 5 STEEL THRUBOLTS, 3/4" FROM ANY EXISTING HOST ALUMINUM EDGE, 1" MIN. SPACING. STRUCTURE BOLTS MAY BE INSTALLED THROUGH ONE OR BOTH WALLS OF HEADER. SHUTTER RAIL (3) 1/4" 18-8 SS OR COATED SAE GR. 5 STEEL THRUBOLTS, 3/4" FROM ANY ALUMINUM EDGE, 1" MIN. SPACING. (2) ANCHORS PER SCHEDULE 'B' 3 BUILD -OUT MOUNT 15 N.T.S. HORIZ SECTION 5 WALL MOUNT 15 N.T.S. VERT SECTION (2) 3/8" 18-8 SS OR COATED SAE GR. 5 STEEL THRUBOLTS, %" FROM ANY ALUMINUM EDGE, 1" MIN. SPACING. ROLL -UP BOLTS MAY BE INSTALLED THROUGH SHUTTER ONE OR BOTH WALLS OF HEADER. SYSTEM PER THIS I I i APPROVAL " MIN.j}f--+Y," MIN. EXISTING HOST /} I I HEADER PER STRUCTURE / I 1'I MIN. HEADER SCHEDULES MIN. SPACING PER EMBED. I i 15 SCHEDULE 'B' 1 I 1 (3) Y4" 18-8 SS OR COATED I SAE GR. 5 STEEL THRUBOLTS, I I I 3/4" FROM ANY ALUMINUM 31 MIN. I I EDGE, 1" MIN. SPACING. BUILD -OUT TUBE I SHUTTER RAIL 6 BUILD -OUT MOUNT 15 N.T.S. VERT SECTION N EXISTING HOST It STRUCTURE I LLuWJ z WJ U E (2) ANCHORS PERQ' EQ'I W^ rn uj Ln�LL Lo 'B' xzSCHEDULE p = wW U mix n� U� z Q—.w �Q W oWU' EMBED. / ZX Or co oz� a 15 K N 0 (9 Lu J M Z Lu U '-I W a LLL o 2:() �W INTERIOR MOUNT ow oo 15 N.T.S. ELEV SCHEDULE 'B' ANCHOR TYPE MINIMUM SPACING MINIMUM EDGE DISTANCE MOUNTING CONDITION NUMBER OF ANCHORS CONNECTION CAPACITY 3/8" DEWALT SCREW BOLTS W/ 3-1/2" EMBED TO 3KSI MIN. CONCRETE 4.5" 4.5" BUILD -OUT OR WALL MOUNT 1 2205 LB 2 3093 LB INTERIOR MOUNT 1 LB 2 065 3065 LB 2.5" 4.5" BUILD -OUT OR WALL MOUNT 1 1477 LB 2 2955 LB INTERIOR MOUNT 1 1272 LB 2 2544 LB 3/8" DEWALT SCREW BOLTS W/ 3-1/2" EMBED TO GROUT -FILLED CONCRETE BLOCK` 6.0" 12.0" BUILD -OUT OR WALL MOUNT 1 1290 LB 2 2580 LB INTERIOR MOUNT 1 1100 LB 2 2200 LB 3/8" DEWALT STEEL DROPIN W/ 1-9/16" EMBED TO 3KSI MIN. CONCRETE 4.5" 5.25" BUILD -OUT OR WALL MOUNT 1 795 LB 2 1590 LB INTERIOR MOUNT 1 1145 LB 2 2290 LB 2.5" 5.25" BUILD -OUT OR WALL MOUNT 1 461 LB 2 922 LB INTERIOR MOUNT 1 664 LB 2 1328 LB 5/16" ITW TAPCON XL OR DEWALT ULTRACON W/ 2-1/4" MIN. EMBED TO 3.5KSI MIN. CONCRETE 5.0" 4.0" OR BUILD -OUT WALL MOUNNTT 1 788LB 2 1576 LB INTERIOR MOUNT 1 851 LB 2 1702 LB 5/16" ITW TAPCON XL OR DEWALT ULTRACON W/ 2-1/4" MIN. EMBED TO GROUT -FILLED CONCRETE BLOCK 5.0" 3.125" BUILD -OUT OR WALL MOUNT 1 292 LB 2 584 LB INTERIOR MOUNT 1 372 LB 2 744 LB 5/16" LAG SCREW W/ 2" MIN. THREAD PENETRATION TO G=0.42 MIN WOOD 2.0" 1.25" BUILD -OUT OR WALL MOUNT 1 655 LB 2 1311 LB INTERIOR MOUNT 1 151 LB 2 301 LB NOTES: 1. ALL ANCHORS SHALL BE 3/4" MINIMUM FROM ANY ALUMINUM EDGE. 2. ` ANCHOR SHALL PENETRATE THROUGH FACE SHELL INTO GROUTED CELL. 3. SEE ANCHOR NOTES ON SHEET 13. Ln M N .-I LL w-9 �LL �a' °C) O M a m p =8 u � ZmA Qu- z ui U cow Q � H w Q og w � w u� o Q �4 oo n p N vvaoco - =m�mz U LL U LL - z z z m m 10 LL�o �a zap_ o' m U U U Q <nm mm � LL LL LL m a o� z - COPYRIGHT FRANK L. BENNARDO P E. 20-2618Ob W5 MAESTROSHIELD ALUMINUM ROLL -UP SHUTTER WITH NON -END RETENTION SLATS AND RAILS 88.375" MAX. UNIT WIDTH WITHOUT STORM BARS & WITHOUT END RETENTION SLATS VCHOR JLE FOR 'ACING JCTURAL JNTED 2T #30) ACED )M OF D WITH JOR E @ 16" -82.1" MAX SLAT SPAN NON -END RETENTION 1 SHUTTER W/O STORM BARS 1 N.T.S. EXTERIOR ELEV TABLE 1 NON -END RETENTION NO STORM BARS SLAT SPAN ALLOWABLE DESIGN PRESSURE POSITIVE NEGATIVE 47.1" + 120.0 PSF 120.0 PSF 50.0" + 100.5 PSF 104.2 PSF 55.0" + 74.0 PSF 83.1 PSF 60.0" + 55.8 PSF 67.3 PSF 65.0" + 39.7 PSF 55.2 PSF 70.0" + 28.9 PSF 45.7 PSF 75.0" + 21.4 PSF 38.2 PSF 80.0" + 16.2 PSF 32.2 PSF 82.1" + 14.5 PSF 30.0 PSF TABLE 1 & 2 NOTES: TABLE 2 MINIMUM GLAZING SEPARATION NON -END RETENTION SLAT SPAN INSTALLATIONS <_ 30' ABOVE GRADE INSTALLATIONS > 30' ABOVE GRADE 47.1" 3.1" 2.5" 50.0" 3.1" 2.7" 55.0" 3.1" 2.8" 60.0" 3.1" 3.0" 65.0" 3.1" 3.0" 70.0" 3.1" 3.0" 75.0" 3.1" 3.0" 80.0" 3.1" 3.0" 82.1" 3.1" 3.0" SLAT SPAN IS DEFINED AS THE DISTANCE BETWEEN RAILS FOR SINGLE SPAN ASSEMBLIES. LINEAR INTERPOLATION BETWEEN SHUTTER SPANS IS NOT PERMITTED. FOR SPANS BETWEEN THOSE INDICATED ABOVE, THE DESIGN PRESSURES FOR THE NEXT HIGHER SPAN SHALL BE USED. SEPARATION FROM GLAZING IS ONLY REQUIRED WITHIN THE HVHZ. GENERAL NOTES 1. THE SYSTEM DESCRIBED HEREIN HAS BEEN DESIGNED AND TESTED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE SEVENTH EDITION (2020), THE INTERNATIONAL BUILDING CODE (IBC) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC), FOR USE WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. SEE EVALUATION REPORT FOR ADDITIONAL INFORMATION. 2. NO 33-1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. WIND LOAD DURATION FACTOR Cd=1.6 HAS BEEN USED FOR WOOD ANCHOR DESIGN. 3. POSITIVE AND NEGATIVE DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED PER SEPARATE ENGINEERING IN ACCORDANCE WITH THE GOVERNING CODE. PRESSURE REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH ASCE 7 AND CHAPTER 1609 OF THE FLORIDA BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE POSITIVE OR NEGATIVE DESIGN PRESSURE CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. 4. DESIGN PRESSURES NOTED HEREIN ARE BASED ON MAXIMUM TESTED PRESSURES DIVIDED BY A 1.5 SAFETY FACTOR. 5. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. THIS CERTIFICATION IS VALID FOR USE IN CONJUNCTION WITH THE MOST CURRENT REVISION OF FLORIDA PRODUCT APPROVAL #FL14235.1, ALUMINUM STORM BARS, HEADERS, & MULLIONS 6. ROLL -UP MECHANISM AND HOOD ASSEMBLY ARE NOT PART OF THIS APPROVAL. 7. THIS DOCUMENT CONTAINS INFORMATION RELEVANT TO THE NECESSARY STRUCTURAL REQUIREMENTS OF THE SYSTEM INSTALLATION. COMPONENTS AND FASTENERS NOT REFERENCED WHICH ARE PART OF THE INTERNAL FABRICATION OF THE SPECIFIED SYSTEMS OR ASSEMBLIES SHALL BE PER MANUFACTURER PUBLISHED SPECIFICATIONS. 8. PERMIT HOLDER SHALL VERIFY THE ADEQUACY OF THE EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS. WOOD BUCKS (BY OTHERS) SHALL BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE EXISTING STRUCTURE. 9. ALL EXTRUSIONS SHALL BE MINIMUM 6063-T5 ALUMINUM ALLOY, UNLESS NOTED OTHERWISE. 10. EACH SHUTTER ASSEMBLY SHALL BEAR A PERMANENT LABEL ON THE BOTTOM OF THE HOOD FACING THE EXTERIOR WITH THE FOLLOWING MINIMUM INFORMATION: TOWN & COUNTRY INDUSTRIES FORT LAUDERDALE, FL 9LB MISSILE LEVEL D - TAS 201, 202 AND 203 FLORIDA PRODUCT APPROVAL NUMBER 11. ALL BOLTS & WASHERS SHALL BE ZINC COATED STEEL, GALVANIZED STEEL, OR STAINLESS STEEL WITH A MINIMUM TENSILE YIELD STRENGTH OF 60 KSI. ALL ALUMINUM 3/16"0 OR 1/4"0 POP RIVETS SHALL HAVE A MINIMUM SHEAR ULTIMATE STRENGTH OF 42ksi. 12. ALL STEEL IN CONTACT WITH ALUMINUM SHALL BE PAINTED OR PLATED AS PRESCRIBED IN THE FLORIDA BUILDING CODE. VISIT ECALC.10/26180a FOR SITE SPECIFIC DEVIATIONS & MORE INFORMATION ABOUT THIS DOCUMENT OR SCAN THIS OR CODE VISIT ENGINEERINGEXPRESS.COMISTORE FOR ADDITIONAL PLANS, REPORTS & RESOURCES FRANK BENNARDO,PE PE# 0046549 CA#9885 III 02,/01/2021 U � N ZoI _ ' ox uJ o--i J � 'i U r^ U U Ww� M d l n W `� ZQ O 2�Wa w Lu � U � z W �Q<1 W Z� az 4 m mow; Izw a z z V) D' F w LLl ow M N J LL On ; ui o a o p rn } I„ a o � R M = Co J z LL J c� a � � p LU LU � w w c p O Q Q O J ca v cv v � a w �! u2 �! o N r-- a��o��n O O N ?z�- Q N 7 OD O - z = U LL LL U � tY - z >Z >Z �a NU Y w �v=im mm og S - m�a�o COPYRIGHT FRANK L. BENNARDO P.E. 20-26180a OF a FRANK BENNARDO,PE PE# 0046549 CA#9885 )T Y 0.150" F 0.083" T.744" m 00 0.150" r-i 1.724' 3.150" 8 SIDE RAIL 6" = 1'-0" 6063-T6 ALUM 3" MIN 8" MAX. �X 0.125" MIN. i L 0.250" MAX. NOTE: SEE BILL OF MATERIALS (BOM) FOR TUBE SIZES AND MATERIALS LiE2.595" 0.552" 0.047" MIN, TYPICAL 11 TYPICAL SLAT 0" 6063-T6 ALUM 1� zQ 0.125" �M I 1 2.75" MIN. 5.75" MAX. Fy = 30 ksi MINIMUM �j ALUMINUM TUBE qD STEEL REINFORCEMENT E 6" = 1'-0" MAT'L PER BOM 6" = 1'-0" A36 GALV. STEEL OR STAINLESS STEEL (� BILL OF MATERIALS ITEM # DESCRIPTION MATERIAL 1 HOOD TOP 3105-H14 ALUM 2 HOOD FACE 3105-H14 ALUM 3 SIDE CAP, RIGHT CAST ALUM 4 MOTOR TUBE, 60-88mm DIAMETER, 3mm THICK 6063-T5 ALUM 4 MOTOR TUBE, 60-100mm DIAMETER, 3mm THICK GALV. STEEL 5 SIDE CAP, LEFT CAST ALUM 6 IDLE BEARING NYLON/STEEL 7 MANUAL GEAR OR ELECTRONIC MOTOR 8 SIDE RAIL, NON -END RETENTION 6063-T6 MIN. ALUM 11 TYPICAL SLAT 6063-T6 ALUM 12 1 "x3"xO.125" TUBE 6063-T6 ALUM 13 2"xTW.125" TUBE 6063-T6 ALUM 14 2"x4'W.125" TUBE 6063-T6 ALUM 15 2"x5"xO.125" TUBE 6063-T6 ALUM 16 2"xTW.25" TUBE 6061-T6 OR 6005-T5 ALUM 17 2"x4"x0.25" TUBE 6061-T6 OR 6005-T5 ALUM 18 2"x5"xO.25" TUBE 6061-T6 OR 6005-T5 ALUM 19 2"x6x0.125" TUBE 6063-T6 ALUM 20 2"x6x0.25" TUBE 6061-T6 OR 6005-T5 ALUM 21 3"xTW.125" TUBE 6063-T6 ALUM 22 3"xTW.25" TUBE 6061-T6 OR 6005-T5 ALUM 23 4'W'W.125" TUBE 6063-T6 ALUM 24 4"x4"xO.25" TUBE 6061-T6 OR 6005-T5 ALUM 25 4"x6"0.25" TUBE 6061-T6 OR 6005-T5 ALUM 26 4"x8"xO.25" TUBE 6061-T6 OR 6005-T5 ALUM 27 STEEL REINFORCEMENT F = 30 ksi MIN. A36 OR STAINLESS STEEL 28 ALUMINUM ANGLE 6061-T6 OR 6005-T5 ALUM 29 OPTIONAL BOTTOM SLAT 6063-T5 ALUM 30 WALL MOUNTED STOP 6063-T6 ALUM T zX M 0.250" 2" MIN. 7" MAX. 28 ALUMINUM ANGLE 0" 6061-T6 OR 6005-T5 ALUM T Z_ Q 1" MIN. 7" MAX. r-2.200"----i 1.440" Q 0.300" 0.042" MIN, TYPICAL OPTIONAL 29 BOTTOM SLAT 6" = 1'-0" 6063-T5 ALUM 30 WALL MOUNTED STOP -0" 6063-T6 ALUM I 02,/F---�L 0i 021 O N Z O� �c I M BYO Wi-. J �uiU W EDr^ U LL (n LL M (n W LL aw Z O owa r_nnn wW U�c7a Ur F> a z W a W o W U Zkaz� KN 0 40Lu O J M Z W a L o E U (n c F w w O W C) li Lr M N J LL N 3 o0 a� aM C) M c' M Cl a s �zm m IJi z a U J � �a Wo =5 O a Q O J v N LL N o v W H r' N oy-- a = coU m z �: U LL U LL K z- z z zco O Y Of w U �oo P LL �a i3�r N Y w In LL LL m LL - Lu a z - COPYRIGHT FRANK L. BENNARDO P.E. 20-26180a 0 E E FRANK BENNARDO,PE PE# 0046549 CA#9885 'F--36 CONTINUOUS %" THICK 6063-T5 OG�/oi 1 HOOD END CAPS ANCHORED TO ALUM. ANGLE (SIZE VARIES PER HOST STRUCTURE ABOVE WITH TOP OF HOOD ANCHORED TO HOOD END CAPS BUILD -OUT DISTANCE), FASTENED TO ANY (2) ANCHORS FROM EXISTING HOST STRUCTURE FULL ANCHORED TO TOP D- HOOD WITH E), SAE NE 2 ANCHOR SCHEDULE EACH SIDE 1 BUILD -OUT TUBE 0 N HOOD ANCHORED TO HOST LENGTH WITH ANY /4"O ANCHOR FROM SMS OR 3/6" POP RIVETS @ 16" O.C., O i ANCHOR SCHEDULE @ 16" O.C. WITH (2) #14 SAE Z � It STRUCTURE WITH ANY /4"� ANCHORED TO HOST STRUCTURE It Z EXISTING HOST GR. 2 SMS EACH ® Lu m 0 � ANCHOR FROM ANCHOR ANCHORS SHALL HAVE 1/Z" MIN EDGE THROUGH 1" LEG WITH ANY %4"O rr^^ [- m � U O j SCHEDULE @16" O.C.; STRUCTURE DISTANCE FROM ANY ALUMINUM EDGE SIDE ANCHOR FROM ANCHOR SCHEDULE VnJ W `" J rn U) U Wr LL M K ui Lu ANCHORS SHALL HAVE 1/Z" @16" O.C.; ANCHORS AND FASTENERS W'VJ to MIN EDGE DISTANCE FROM E EXISTING HOST j SHALL HAVE %Z" MIN EDGE DISTANCE 7 W U m � Lu w � ANY ALUMINUM EDGE. STRUCTURE FROM ANY ALUMINUM EDGE. ANGLE Q W w U Z x LEG MAY BE POSITIONED UP OR �� " Q wow c3 HOOD END CAPS ANCHORED DOWN. (SEE DETAIL 4/4 FOR Zk a m o z TO HOST STRUCTURE WITH ALTERNATE) ON 0 M w w ANY (2) ANCHORS FROM 0 � @ z ANCHOR SCHEDULE � U HOOD END CAPS ANCHORED Lr) EXISTING HOST E O �J i i TO INTERIOR MOUNT O �`� w ~ W STORM BAR INTERIOR !I , O O , HEADER PER STRUCTURE MOUNT CONNECTION PER i TUBE/ANGLE WITH (2) #14 0 p SAE GR. 2 SMS EACH SIDE ADDENDUM ,1 ADDENDUM INSTALLATION i i INSTALLATION i 0 O INSTRUCTIONS I� ® INSTRUCCTTIOONS i i Ln OPTIONAL / ii li i STORM BAR TO HEADER CONNECTION/ STORM BAR INTERIOR n // i O O i HEADER PER / it l I DETAILS PER ADDENDUM I ADDENDUM INSTALLATION INSTRUC MOUNT CONNECTION I INSTALLATION s PER ADDENDUM i i i i 0 O INSTRUCTIONS 1/4" MINIMUM it I I I I (HVHZ ONLY) ii i i i OPTIONAL HEADER INSTALLATION I II 1 ! I I� II STORM BAR TO HEADER INSTRUCTIONS !• II ' ' I CONNECTION DETAILS I ; ; OPTIONAL HEADER PER I PER ADDENDUM i INSTALLATION ,I I I I i i II = I it I I I PER ADDENDUM i�—, ADDENDUM INSTALLATION II , , '�~� �� INSTALLATION i i 0 O, INSTRUCTIONS } Q m INSTRUCTIONS i o i I I 1 i INSTRUCTIONS / i l ; I ' ' 1 i n a"d O m I I I I I I I ii i i i O O i II ' i I i = 1 � m MIN. GLASS SEPARATION i i i ! MIN. GLASS SEPARATION/ li i MIN. GLASS SEPARATION I i i !� a ANCHORS INTO HOST ; ; z Q PER SCHEDULE I I �, , , PER SCHEDULE �, STORM BAR TO PER SCHEDULE I I 1 ; , STORM BAR TO C _m z li I I I STRUCTURE PER ;; ; ; ; ; II ' ' 1 ; a U w 1 i i ANCHOR SCHEDULE ;; i� i i HEADER CONNECTION ii i i i HEADER CONNECTION @ a �i-- I I 1 EXISTING HOST _ __ i i i i DETAILS PER EXISTING HOST ' I i i ! i DETAILS PER N p OPTIONAL INTERIOR ADDENDUM ADDENDUM �_. STORM BAR PER STRUCTURE STRUCTURE o JJJ INSTALLATION INSTALLATION ADDENDUM BEYOND BEYOND INSTRUCTIONS INSTRUCTIONS 0 ¢ INSTALLATION 1 I ' ' I , I I, , , , ' I ' ' ' I I 1 1 I , , , i li i I j ) O J INSTRUCTIONS i 1 i f/ li I i ' ii i g' v F LL INTERIOR i EXTERIOR INTERIOR �✓ li I i EXTERIOR INTERIOR �i j i EXTERIOR v �1Cv � �✓ li I i ANCHORS TO EXISTING HOST /11 I I , I 1 STRUCTURE BEYOND�]I i i i i I� i INTERIOR MOUNT OPTIONAL INTERIOR H = I I 1 I I OPTIONAL INTERIO I� , , TUBE/ANGLE PER STORM BAR PER 11 ANCHORS TO �' i STORM BAR PER /� ADDENDUM �i 1 I 1 ANCHOR SCHEDULE , , BUILD -OUT TUBE PER 13/4" MINIMUM �' I 1 i I OPTIONAL ADDENDUM ^i % I' i i i INSTALLATION �� = i ANCHOR SCHEDULE I ' I " ' ' ' (HVHZ ONLY) it i O O i i i EXTERIOR STORM BAR PER INSTALLATION I� i INSTRUCTIONSLu 11 i i i N o m rum i i � N�sINSTRUCTIONS OPTIONAL EXTERIOR v co ,z s�ADDENDUM INSTALLATION STORM BAR PER Hw1 I INSTRUCTIONS li li i i ADDENDUM STORM BAR INTERIOR i STORM BAR INTERIOR ii ; ; 13/4" MINIMUM 1 = ; 1 ; Y m J m z MOUNT CONNECTION PER i i MOUNT CONNECTION. ii li ; i INSTALLATION 1 , x J n J � ozo (HVHZ ONLY) I 1 1 O LL O LL I INSTRUCTIONS _ I ADDENDUM INSTALLATION 1 I REFERENCE STORM BAR Z wk INSTRUCTIONS i i CONNECTION DETAILS.,\ i li i i OPTIONAL EXTERIOR a Of W 0 coxo = STORM BAR INTERIOR I I i STORM BAR PER o Y �30 EXISTING HOST / ii i EXISTING HOST !i \\li i i I i , ADDENDUM O MOUNT CONNECTION PER �60� STRUCTURE ii i STRUCTURE iji; I i i ADDENDUM INSTALLATION ; O O i i 0 O i INSTALLATION Wow n I h i O O I i O O; INSTRUCTIONS �_ __ ___ _ __ _ INSTRUCTIONS �3¢F II I STORM BAR WALL MOUNT m m O i CONNECTION PER EXISTING HOST STORM BAR BUILD -OUT w a o !! ! ADDENDUM STRUCTURE�� MOUNT CONNECTION PER � z o INSTALLATION ADDENDUM INSTALLATION COPYRIGHT FRANK L. BENNARDO P.E. INSTRUCTIONS INSTRUCTIONS 20-26180a WALL MOUNT (SHOWN INTERIOR MOUNT (SHOWN BUILD -OUT MOUNT (SHOWN SCALE: - PAGE DESCRIPTION: i W/ OPTIONAL STORM BARS 2 W/ OPTIONAL STORM BARS 3 W/ OPTIONAL STORM BARS 3 N.T.S. VERT SECTION 3 N.T.S. VERT SECTION 3 N.T.S. VERT SECTION 7oF- 0 NOTE: FOR OPTIONAL MOUNTING CONDITIONS, NOTE: FOR OPTIONAL MOUNTING CONDITIONS, NOTE: FOR OPTIONAL MOUNTING CONDITIONS, REFERENCE ADDENDUM STORM BAR AND REFERENCE ADDENDUM STORM BAR AND REFERENCE ADDENDUM STORM BAR AND MULLION INSTALLATION INSTRUCTIONS. MULLION INSTALLATION INSTRUCTIONS. MULLION INSTALLATION INSTRUCTIONS. EXISTING HOST STRUCTURE ANCHORS ANCHOR SCHEI INTERIOR FXTFRTr)D MIN. GLASS SEPARATION PER SCHEDULE NON -END RETENTION 1 TYPICAL WALL MOUNT 4 N.T.S. HORIZ SECTION EXISTING HOST STRUCTURE BUILD -OUT ANCHORS PER ANCHOR SCHEDULE WALL -MOUNT ANCHO PER ANCHOR SCHEDU ANY ALUMINUM TUBE FROM BILL OF MATERIALS HOLE PLUG INTERIOR iy.rrmiraru EXISTING HOST MIN. GLASS STRUCTURE SEPARATION PER SCHEDULE INTERIOR MOUNT Lu (D � ANCHORS PER L p ANCHOR SCHEDULE /�EMBED./B// E ACCESS HOLE NON -END RETENTION 2 TYP. BUILD -OUT MOUNT 4 N.T.S. HORIZ SECTION CONTINUOUS %$" THICK 6063-T5 ALUM. ANGLES (SIZE VARIES PER BUILD -OUT DISTANCE) ANGLE ANCHORED THRU TYP 1" LEG W/ ANY %4"O ANCHOR FROM ANCHOR SCHEDULE @16" O.C., 1/2" MIN EDGE DIST. FROM T) ANY ALUM EDGE 11 HOOD j 1" MAX, Lu %2" MIN x//// L %4"-20 THRU-BOLT W/ NUT PER WALL MOUNT ANCHOR SCHEDULE (2) ROWS OF %4" 18-8 SS OR COATED SAE GR. 5 STEEL THRUBOLTS, 16" O.C. #14 18-8 SS OR COATED SAE GR. 5 STEEL SMS @ 16" O.C., 1/z" MIN EDGE DIST. FROM ANY ALUM EDGE ALTERNATE BUILD -OUT HOOD CONNECTION N.T.S. SECTION HOLE PLUG INTERIOR [ANY ALUMINUM TUBE OR ANGLE FROM BILL OF MATERIALS MIN. GLASS SEPARATION PER SCHEDULE cy �I a �I w 1 1/4" 11 MIN. 8 FXTFRTr)D NON -END RETENTION 3 TYP. INTERIOR MOUNT 4 N.T.S. HORIZ SECTION FRANK BENNARDO,PE PE# 0046549 CA#9885 IF--3 02,/0i 21 N Z o� �r®^ [_ Y0 V, W �-. J ui U rn U W LL (n W M CL LLo u W LLaw Z0 owa rt wW U�c7a U Q °F i Q z W �a W oW(� Zkat°Doz� KN 0 �C7w 0� W Mww 7 ti LL o E U (n F w w O W C) li Lr M N J LL N 3 �ILr, o0 a, aM O M � � 3 E M p a s �zm m IJi z a U J � �a Wo 0 a Q O J 41 V N LL v o v w H u o N �x-- =m ca U) z U LL U LL K - �k > Z Kwi: Z Z i�m x5=? O Y Of W U �oo LL�o� �a Y w mmm � _ W - COPYRIGHT FRANK L. BENNARDO P.E. 20-26180a 4