Residential Performance Method
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RODOLFO VEGA gopher ridge Builder Name: Street: 960 GOPHER RIDGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: RODOLFO VEGA Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(2488.9 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block-Ext Insul, ExterioR=5.7 2171.60 ft2 3. Number of units, if multiple family 1 b. Frame-Wood, Adjacent R=11.0 317.33 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(2276.0 sqft.) Insulation Area a. Roof Deck(Unvented) R=20.0 2276.00 ft2 6. Conditioned floor area above grade(ft2) 2276 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 7. Windows(256.7 sqft.) Description Area 12. Ducts, location &insulation level R ft2 a. U-Factor: Sgl, U=0.32 166.69 ft2 a. a. Sup: Attic, Ret: Attic, AH: Garage 6 300 SHGC: SHGC=0.22 b. b. U-Factor: Sgl, U=0.35 90.00 ft2 c. SHGC: SHGC=0.20 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit RECEIVED 34.0 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 3.396 ft OCT 21 2020 Area Weighted Average SHGC: 0.213 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Strip Heat st,pKf I Q Unry 27.0 COP:1.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area 15. Hot Water Systems a. Slab-On-Grade Edge Insulation R= 0.0 2276.00 ft2 a. Electric Cap: 50 gallons b. N/A R= ft2 EF: 0.950 c. N/A R= ft2 b. Conservation features None Glass/Floor Area:0.113 Total Proposed Modified Loads: 72.08 Total Baseline Loads: 72.80 PASS I hereby certify that the plans and specifications covered by Review of the plans and TIME Sr this calculation are in compliance with the Florida Energy specifications covered by this pF A?F .,, Code. calculation indicates compliance' 0.0 with the Florida Energy Code. PREPARED BY:Q��)anxPBefore construction is completed n this building will be inspected for - - flb. -- DATE: ®-� wr.�2_ compliance with Section 553.908 Florida Statutes. ,t I hereby certify that this building, as designed, is in compliance CpD WE.�t�� with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: pv j cs 5NW O DATE: DATE: Jo--.2.0- 20 j - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors,tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). PXVISION 10/21/2021 11:32:00 AM EnergyGauge@)USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Co IL nt SVOMPY Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: RODOLFO VEGA gopher ridge Address type: Street Address Building Type: User Bedrooms: 4 Lot#: --- Owner: RODOLFO VEGA Conditioned Area: 2276 Block/SubDivision: --- Total Stories: 1 PlatBook: --- Builder Name: Worst Case: No Street: 960 GOPHER RIDGE Permit Office: ST.LUCIE COUNTY Rotate Angle: 0 County: St.Lucie Jurisdiction: Cross Ventilation: No City,State,Zip: FT.PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New(From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2270394.400390625 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _1 FAMILY ROOM 252 2368.8 No 0 Yes Yes Yes -2 BATH 2 54 507.6 No 0 Yes Yes Yes -3 BEDROOM 2 172 1616.8 No 1 1 Yes Yes Yes -4 DINIG/KITCHEN 402 3778.8 Yes 0 Yes Yes Yes _5 LIVING ROOM 310 2914 No 0 Yes Yes Yes -6 CLST. 42 394.8 No 0 Yes Yes Yes -7 BEDROOM 3 186 1748.4 No 1 1 Yes Yes Yes _8 BEDROOM 4 156 1466.4 No 1 1 Yes Yes Yes _9 BATH 3 66 620.4 No 0 Yes Yes Yes _10 MASTER BEDROOM 286 2688.4 No 2 1 Yes Yes Yes _11 WIC 50 470 No 0 No Yes Yes _12 M.BATH 121 1137.4 No 0 No Yes Yes _13 LAUNDRY 69 648.6 No 0 Yes Yes Yes 14 OFFICE 110 1034 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 2276 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _1 Slab-On-Grade Edge Ins FAMILY ROOM 44 0 252 ft 0.473 --- 0.00 1.00 0.00 -2 Slab-On-Grade Edge Ins BATH 2 6 0 54 ft 0.473 --- 0.00 1.00 0.00 -3 Slab-On-Grade Edge Ins BEDROOM 2 27 0 172 ft 0.473 --- 0.00 1.00 0.00 -4 Slab-On-Grade Edge Ins DINIG/KITCHEN 18 0 402 ft 0.473 --- 0.00 1.00 0.00 _5 Slab-On-Grade Edge Ins LIVING ROOM 18 0 310 ft 0.473 --- 0.00 1.00 0.00 -6 Slab-On-Grade Edge Ins CLST. 6 0 42 ft 0.473 --- 0.00 1.00 0.00 _7 Slab-On-Grade Edge Ins BEDROOM 3 25 0 186 ft 0.473 --- 0.00 1.00 0.00 _8 Slab-On-Grade Edge Ins BEDROOM 4 25 0 156 ft 0.473 --- 0.00 1.00 0.00 _9 Slab-On-Grade Edge Ins BATH 3 7 0 66 ft 0.473 --- 0.00 1.00 0.00 _10 Slab-On-Grade Edge Ins MASTER BEDROOM 20.6 0 286 ft 0.473 --- 0.00 1.00 0.00 _11 Slab-On-Grade Edge Ins WIC 1 0 50 ft 0.473 --- 0.00 1.00 0.00 12 Slab-On-Grade Edge Ins M.BATH 1 0 121 ft 0.473 --- 0.00 1.00 0.00 10/21/2021 11:32:00 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS(Continued) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _13 Slab-On-Grade Edge Ins LAUNDRY 15 0 69 ft 0.473 --- 0.00 1.00 0.00 14 Slab-On-Grade Edge Ins OFFICE 21 0 110 ft 0.473 --- 0.00 1.00 0.00 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2399 ft2 Uhf iished,Galvanizdd 0.5 No 0.7 No 20 18.43 ATTIC # Type Ventilation Vent Ratio(1 in) Area RIBS IRCC 1 Full attic Unvented 0 2276 ft2 N N CEILING (Total Exposed Area = 2276 sq.ft.) # Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type _1 Under Attic(Unvented) FAMILY ROOM 0.0 Blown 252.0ft2 0.061 0.10 Wood -2 Under Aftic(Unvented) BATH 2 0.0 Blown 54.0ft2 0.061 0.10 Wood -3 Under Attic(Unvented) BEDROOM 2 0.0 Blown 172.0ft2 0.061 0.10 Wood _4 Under Attic(Unvented) DINIGIKITCHEN 0.0 Blown 402.0ft2 0.061 0.10 Wood _5 Under Attic(Unvented) LIVING ROOM 0.0 Blown 310.0ft2 0.061 0.10 Wood _6 Under Attic(Unvented) CLST. 0.0 Blown 42.0ft2 0.061 0.10 Wood _7 Under Attic(Unvented) BEDROOM 3 0.0 Blown 186.0ft2 0.061 0.10 Wood _8 Under Attic(Unvented) BEDROOM 4 0.0 Blown 156.0ft2 0.061 0.10 Wood _9 Under Attic(Unvented) BATH 3 0.0 Blown 66.0ft2 0.061 0.10 Wood _10 Under Attic(Unvented) MASTER BEDROOM 0.0 Blown 286.0ft2 0.061 0.10 Wood _11 Under Attic(Unvented) WIC 0.0 Blown 50.0ft2 0.061 0.10 Wood _12 Under Attic(Unvented) M.BATH 0.0 Blown 121.0ft2 0.061 0.10 Wood 13 Under Attic(Unvented) LAUNDRY 0.0 Blown 69.0ft2 0.061 0.10 Wood 14 Under Attic(Unvented) OFFICE 0.0 Blown 110.Oft2 0.061 0.10 Wood WALLS (Total Exposed Area = 2489 sq.ft.) VAdjacent Cavity Width Height Area U- Sheath Frm. Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _1 NE Exterior Cone.Blk-Ext Ins FAMILY ROOM 5.7 14.0 0 9.0 4 130.7 0.109 0 0 0.40 0% -2 SW Exterior Cone. Blk-Ext Ins FAMILY ROOM 5.7 14.0 0 9.0 4 130.7 0.109 0 0 0.40 0% -3 NW Exterior Cone.Blk-Ext Ins FAMILY ROOM 5.7 16.0 0 9.0 4 149.3 0.109 0 0 0.40 0% -4 NE Exterior Cone.Blk-Ext Ins BATH 2 5.7 6.0 0 9.0 4 56.0 0.109 0 0 0.40 0% _5 NE Exterior Cone.Blk-Ext Ins BEDROOM 2 5.7 13.0 0 9.0 4 121.3 0.109 0 0 0.40 0% _6 SE Exterior Cone.Blk-Ext Ins BEDROOM 2 5.7 14.0 0 9.0 4 130.7 0.109 0 0 0.40 0% _7 SE Exterior Cone.Blk-Ext Ins DINIG/KITCHEN 5.7 12.0 0 9.0 4 112.0 0.109 0 0 0.40 0% _8 NW Exterior Cone.Blk-Ext Ins DINIG/KITCHEN 5.7 6.0 0 9.0 4 56.0 0.109 0 0 0.40 0% _9 SW Exterior Cone.Blk-Ext Ins LIVING ROOM 5.7 18.0 0 9.0 4 168.0 0.109 0 0 0.40 0% _10 SW Exterior Cone.Blk-Ext Ins CLST. 5.7 6.0 0 9.0 4 56.0 0.109 0 0 0.40 0% _11 SE Exterior Cone.Blk-Ext Ins BEDROOM 3 5.7 12.0 0 9.0 4 112.0 0,109 0 0 0.40 0% _12 SW Exterior Cone.Blk-Ext Ins BEDROOM 3 5.7 13.0 0 9.0 4 121.3 0.109 0 0 0.40 0% _13 NE Exterior Cone.Blk-Ext Ins BEDROOM 4 5.7 12.0 0 9.0 4 112.0 0.109 0 0 0.40 0% _14 SE Exterior Cone.Blk-Ext Ins BEDROOM 4 5.7 13.0 0 9.0 4 121.3 0.109 0 0 0.40 0% _15 NE Exterior Cone.Blk-Ext Ins BATH 3 5.7 6.0 0 9.0. 4 56.0 0.109 0 0 0.40 0% _16 SE Exterior Cone.Blk-Ext Ins BATH 3 5.7 1.0 0 9.0 4 9.3 0.109 0 0 0.40 0% 17 SE Exterior Cone.Blk-Ext Ins MASTER BEDROOM 5.7 4.0 0 9.0 4 37.3 0.109 0 0 0.40 0% 10/21/2021 11:32:00 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS(Continued) 18 S Exterior Cone.Blk-Ext Ins MASTER BEDROOM 5.7 2.0 10 9.0 4 26.4 0.109 0 0 0.40 0%_ _19 SW Exterior Cone.Blk-Ext Ins MASTER BEDROOM 5.7 11.0 0 9.0 4 102.7 0.109 0 0 0.40 0% _20 W Exterior Cone. Blk-Ext Ins MASTER BEDROOM 5.7 2.0 10 9.0 4 26.4 0.109 0 0 0.40 0% _21 NE Exterior Cone.Blk-Ext Ins LAUNDRY 5.7 15.0 0 9.0 4 140.0 0.109 0 0 0.40 0% _22 NE Exterior Cone.Blk-Ext Ins OFFICE 5.7 11.0 0 9.0 4 102.7 0.109 0 0 0.40 0% _23 NW Exterior Cone.Bik-Ext Ins OFFICE 5.7 10.0 0 9.0 4 93.3 0.109 0 0 0.40 0% 24 N Garage Frame-Wood OFFICE 11.0 34.0 0 9.0 4 317.3 0.092 0.23 0.40 0% DOORS (Total Exposed Area = 40 sq.ft.) Width Height J# Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area _1 NE Exterior Insulated FAMILY ROOM None 0.39 3.00 0 6.00 8 20.0ft2 2 SW Exterior Insulated LIVING ROOM None 0.39 3.00 0 6.00 8 20.0ft2 WINDOWS (Total Exposed Area = 257 sq.ft.) Wall -----Overhang---- V# Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening _1 NW 3 Vinyl Low-E Single Yes 0.32 0.22 N N 30.0ft2 1.0 ft 5 in 1.0 ft 5 in None None -2 NE 4 Vinyl Low-E Single Yes 0.32 0.22 N N 9.0ft2 1.0 ft 5 in 1.0 ft 5 in None None -3 NE 5 Vinyl Low-E Single Yes 0.32 0.22 N N 15.02 1.0 ft 5 in 1.0 ft 5 in None None -4 SE 7 Vinyl Low-E Single Yes 0.35 0.20 N N 30.02 1.0 ft 5 in 1.0 ft 5 in None None _5 NW 8 Vinyl Low-E Single Yes 0.32 0.22 N N 48.0ft2 12.0 ft 0 in 1.0 ft 5 in None None _6 SW 9 Vinyl Low-E Single Yes 0.32 0.22 N N 30.0ft2 1.0 ft 5 in 1.0 ft 5 in None None _7 SW 12 Vinyl Low-E Single Yes 0.32 0.22 N N 15.0ft2 1.0 ft 5 in 1.0 ft 5 in None None -8 NE 13 Vinyl Low-E Single Yes 0.32 0.22 N N 15.0ft2 1.0 ft 5 in 1.0 ft 5 in None None _9 NE 15 Vinyl Low-E Single Yes 0.32 0.22 N N 4.7ft2 1.0 ft 5 in 1.0 ft 5 in None None _10SW 19 Vinyl Low-E Single Yes 0.35 0.20 N N 30.0ft2 1.0 ft 5 in 1.0 ft 5 in None None 11 NW 23 Vinyl Low-E Single Yes 0.35 0.20 N N 30.0ft2 1.0 ft 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA GFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00042 2496 136.94 257.09 0.1348 7.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 264 ft2 264 ft2 34 ft 9 ft 11 MASS # Mass Type Area Thickness Furniture Fraction Space _1 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 _ FAMILY ROOM -2 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 BATH 2 -3 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 BEDROOM 2 -4 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 DINIG/KITCHEN -5 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 LIVING ROOM _6 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 CLST. _7 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 BEDROOM 3 -8 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 BEDROOM 4 9 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 BATH 3 10/21/2021 11:32:00 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS(Continued) _10 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 MASTER BEDROOM _11 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 WIC _12 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 M.BATH _13 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 LAUNDRY 14 Default(8 Ibs/sq.ft.) 0 ft2 Oft 0.30 OFFICE HEATING SYSTEM # System Type Subtype AHRI# Efficiency Capacity ----Geothermal HeatPump---- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat None COP:1.00 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency . Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split/Single SEER:16.0 34.0 0 0.70 sys#1 1 HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Garage 0.95(0.93) 50.00 gal 61 gal 120 deg Standard None 105 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No' NA NA NA No NA NA NA None DUCTS VDuct ---------Supply--------- ---------Return--------- Air CFM 25 CFM 25 HVAC# # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0300 ft2 Attic 6.0 95 ft2 Default Leakage Garage (Default)(Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans:N Cooling []Jan I]Feb []Mar []Apr []May [X]Jun [X]Jul [X]Aug [X]Sep []Oct []Nov []Dec Heating [X]Jan [X]Feb [X]Mar []Apr []May []Jun []Jul []Aug []Sep []Oct [X]Nov [X]Dec Venting []Jan []Feb [X]Mar [X]Apr []May []Jun []Jul []Aug []Sep [X]Oct [X]Nov []Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 76 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/21/2021 11:32:00 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 960 GOPHER RIDGE,FT. PIERCE,FL, 1. New construction or existing New(From Plans) 10. Wall Types(2488.9 sqft.) Insulation Area .2. Single family or multiple family Detached a. Concrete Block-Ext Insul, ExterioR=5.7 2171.60 ft2 3. Number of units, if multiple family 1 b. Frame-Wood, Adjacent R=11.0 317.33 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(2276.0 sqft.) Insulation Area a. Roof Deck(Unvented) R=20.0 2276.00 ft2 6. Conditioned floor area above grade(ft2) 2276 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 7. Windows** Description Area 12. Ducts, location &insulation level R ft2 a. U-Factor: Sgl, U=0.32 166.69 ft2 a. a. Sup: Attic, Ret: Attic, AH: Garage 6 300 SHGC: SHGC=0.22 b. b. U-Factor: Sgl, U=0.35 90.00 ft2 C. SHGC: SHGC=0.20 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.0 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 3.396 ft Area Weighted Average SHGC: 0.213 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Strip Heat 27.0 COP:1.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area 15. Hot Water Systems a. Slab-On-Grade Edge Insulation R= 0.0 2276.00 ft2 a. Electric Cap: 50 gallons b. N/A R= ft2 EF: 0.950 c. N/A R= ft2 b. Conservation features None 16. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed EVE ST.g1 based on installed Code compliant features. ��� Builder Signature: Date: Address of New Home: 960 GOPHER,RIDGE City/FL Zip: FT. PIERCE,FL, CoLo *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/21/2021 11:32:04 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA" Project Name: RODOLFO VEGA gopher ridge Builder Name: Street: 960 GOPHER RIDGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: RODOLFO VEGA Jurisdiction: w Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation,insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be out to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box The air barrier shall be installed behind electrical or on exterior walls communication boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling penetrated by the boot. Concealed When required to be sealed,concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 10/21/2021 11:32:11 AM EnergyGauge®USA 7.0-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 - - wrightsoft® Project Summary �e: Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772466-6799 Email:QUICKCALCS@,AOL.COM Prowlect Information For: RODOLFO VEGA 960 GOPHER RIDGE,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26341 Bt ih Structure 21638 Btuh Ducts 4257 Btuh Ducts 2838 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30598 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 23252 Btuh Method Simplified -Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3383 Btuh Ducts 2287 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2276 2276 Equipment latent load 5671 Btuh Volume(ft3) 21394 21394 i Airchanges/hour 0.32 0.16 Equipment Total Load(Sen+Lat) 28923 Btuh Equiv.AVF(cfm) 114 57 Req.total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6036J1 AHRI ref Coil TEM6AOB3OH21++TDR AHRI ref 8704409 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 7.8 kW Sensible cooling 23800 Btuh Heating output 26550 Btuh Latent cooling 10200 Btuh Temperature rise 21 OF Total cooling 34000 Btuh Actual air flow 1133 cfm Actual air flow 1133 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t -Pk wrightsoft, 2021-Oct-2111,30:04 �••��.a�,�..4 M. Right Sulte®Univereal 202121.0.08 RSU08101 Page 1 ACCA .,,1Wrlghtso8H\1GNEGA,RODOLFO-GOPHERRIDGE.rup Calr=MJ8 Front Door faces:SE wrightsoft Right-M Worksheet J°ir Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.00M 1 Room name Entire House FAMLYROOM 2 Exposed wall 267.6 ft 44.0 ft 3 Room height 9.4 It 9A ft heat/cool 4 Room dimensions 1.0 x 252.0 ft 5 Room area 2276.0 ft' 252.0 ft' Ty Construction U-value Or HTM Area (fF) Load Area (fl) Load number (BtuhfiP--°F) PUMP) or perimeter (fl) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 'W 13A-5ocs - 0:125 ne 3.50 1al 724 659 '2307 1260 132 111 387. 212 4A5-2ob 0.560 ne 15.68 33.75 5 0 75 161 0 0 0 0 AA5 lob , 0.560 ne 15B8 33.76 9 0 141 304' 0 0 0 0 4A5-2ob 0.560 ne. 15.68 33.75 30 0 470 1012 0 0 0 0 11 _ D.11D0-.`..._ 0.390 ne 10.92 _ 10.34 21 21 229 .1217 21 21 .. 229 217 13A5ocs 0.125 se 3.50 l all 526 496 1737 949 0 0 0 0 T-G 4A5-2ob 0.560 se 15.68 25.15 30 15 470 _ 755 0 0 0 0 W... 13A Socs 0.125 s. 3.50 1.01 27 27 93' 51' 0' 0 0 0 VIU _ 13A-5ocs 0.125 sw 3.50 1.91 583 487 1704 931 132 132 461 252 4A5-20b 0.560 sw 15.68 25.15 15 7 235 377 0 0 0 0 4A5-2ob 0.560 sw 15.68 25.15 60 30 941 1509 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 21 21 229 217 0 0 0 0 UV 13Aocs- _. _ U.125 w 350 .._ 191 ,- ,•,27 27 93 ...._.. 51 .0.. 0... 0 0 W 13A-5ocs 0.125 nw 3.50 1.91 301 193 675 369 150 120 421 230 4A5-2ob 0560 nw 15.68 33.75 60 0 941 2025 30 0 470 1012 4A5-2ovd 0.470 nw -. 13.16 2829 48 0 632 1358 0 0 0 0 P "12C-0sw ` 0.091 2S5 1.06 329 329, 838 347 0 0. 0 0 C 16X19-oml 0.408 - 159 1.13 2276 2276 3609 2577 252 252 400 285 F 22A-tpl. 0.989 - 27.69' 0.00 2276 2W 7410 0 252 44 1218 0 , 6 c)AED excursion 2078 372 Envelope loss/gain 22829 M48 3587 2581 12 a) Infiltration 3511 941 664 178 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 0 0 Appliances/other 3000 1000 Subtotal(lines 6to 13) 26341 21638 4251 3758 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26341 21638 4251 3758 15 Duct loads 16% 13% 4257 2838 16% 13% 687 493 Total room load 30598 24476 4938 4251 Air required(cfm) 1133 1133 183 197 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fli- wrightoof't- 2021.Oct-2111:30:04 C.�A °�°•^ -� Right-Sulte®Universal 202121.0,08 RSU08101 Page 1 \WrlghtsoftHUAQVEGA,RODOLFO-GOPHER RIDGE.rup Calo=MJB Front Door faces:SE - -wrrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKC4LCS@AOL.00M 1 Room name BATH 2 BEDROOM 2 2 Exposed wall 6.0 ft 27.0 It 3 Room height 9A It heat(cool 9.4 ft heaUcool 4 Room dimensions 6.0 x 9.0 It 1.0 x 172.0 ft 5 Room area 54.0 ft2 172.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft?) Load number (Btuh/fP--°F) (BtuhAF) or perimeter (ft) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IW �13A-5ocs 0.125 ne 3.60 9.61 56 47 166 -91'-- 122 '107 375 265 I- G 4P5-2ob OWO. ne 15.68 33.75. 0 0 0 0 0 0 0 0 4A5-2ob. 0S60 ne 16.68 33.76 9 0• 141 304 0 0 0 0 4A5-26b 0560 he 15.68 33.76 p 0 0 0 15 0 235 506 11 -. 11D0 '' . _ .0.390 ne 10.92 - 10.34. 0 0 .. - -0 0 -0 0 0 0 13A 5ocs 0.125 se 3.50 1.91 0 0 0 0 132 132 461 252 Y--G 4A5-2ob 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 W. 13A-5ocs 0.125 s 350 1:91 0 0 0 0 0 0 0 0 13A5ocs 0.125 sw 3.50 1.91 0 0 0 0 0 0 0 0 4A5-20b 0.560 sw 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 sw 15.68 25.15 0 0 0 0 0 0 0 0 D 11 DO 0" sw 10.92 10.34 0 0 0 0 0 0 0 0 W 13A5ocs_. 0.125.w_ 350'.. . .1.91 0 0 . 0•..-- - 0 `0 0 0 0 W 13A5ocs 0.125 nw 3.50 121 0 0 0 0 0 0 0 0 iI-CGI 4AS-2ob 0.560 nw 15.68 33.75 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 nw 13.16 2.829 0 0 0 0 0 0 0 _ 0 P 12C 0sw 6.091 2.55 1:06 0 . 0 0 0 0 _ 0 0 0 C 16X19-Oml 0.408 - _ 1.59 1.13 54_ 54 86 61 172 172 2M 195 F` , 22A-tpf _ 0.989 :.- 27.69 0.00 54 6 166 6 172 27. 748 0 6 c)AED excursion -7 -21 Envelope loss/gain 559 449 2091 1136 12 a) Infiltration 91 24 407 109 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 01 0 Subtotal Qines 6 to 13) 649 473 2499 1475 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 649 473 2499 1475 15 Duct loads 16% 13% 105 62 16% 13% 404 193 Total room load 764 535 2903 1669 Air required(cfm) 28 25 107 77 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C Ai- wrflghtaoT•t- 2021-Oct-21 11:30:04 . °u • Um- Right-Sulte®Universal 202121.0.08RSU08101 Paget 1Wrightsoft H\AC%VEGA,RODOLFO-GOPHER RIDGE.rup Calc=MJ8 Front Door faces:SE -�-wrightsofts Right-J®Worksheet Date: Entire House Dal QUICK CALCS, INC. 317 ST,LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name DINIG ITCHEN LIVING ROOM 2 Exposed wall 18.0 It 18.0 ft 3 Room height 9A It heat/cool 9A ft heat/cool 4 Room dimensions I D x 402.0 ft 1.0 x 310.0 It 5 Room area 402.0 IF 310.0 W Ty Construction Ll-value Or HTM Area (" Load Area (fF) Load number (BtuhHF--°F) (BtuhAn or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-5ocs 0.125 ..ne . . 350 1'.91` . 6 0 -0. 0 0 0 0 0 �--G 4A5-2ob 0.560 ne 15.68 33.75 0 0 0 0 0 0 0 0 4A5-2ob 0.560 ne 15.68 33.75, 0 0 0 0 0 0 0 0 �G 4A5-2ob 0.560 ne 15.68 33.75 0 0 0 0 0 0 0 0 11 D 11 D0. 0.390, ne, 10.92 10.34 0 ' _ 0. 0 0 0 0: 0 _ 0 UV 13ASocs 0.125 se 3.50 1 D1 113 83 290 158 0 0 0 0 L-G 4A5-2ob 0.560 se 15.68 25.15 30 15 470 755 _ 0 0 0 0 W _ •• 13A-506s-° 0.125•-s. 3.50•" 1;:91 0 0 0 0. 0 0 . . 0 ... 0 �-!D 13ASocs 0.125 sw 3.50 1.91 69 0 0 0 0 1 118 414 226 4A5-2ob 0.560 sw 15.68 25.15 0 0 0 0 0 0 0 0 4A5.2ob 0.560 sw 15.68 25.15 0 0 0 0 30 15 470 755 11DO 0.390 sw ,_,.10.92 _ 10.34 0•.- 0 _ 0 __. 0 21 21, 229 217 W 13R Sdcs 0.125 -.w 3a0 - - 1.97 0 0 0 0. 0 0 0 0 W 13ASocs 0.125 nw 350 1.91 56 8 29 16 0 0 0 0 4A5-2ob 0560 nw 15.68 33.75 0 0 0 0 0 0 0 0 4A5-2ovd OA70 nw - 13.16 2829 48 0 632 1358 0 0, 0 _ 0 P. 12C-0sw . 6.091` - 2.% 1 A6:, -0 0 0. 1 0 . ' 0 0 0 0 C 16X19-0m1 0.408 _-_ 1.59 1.13 402 402 637 455 310 310 492 351 IF 22A-tpl- 0.989 - 27,69 0.00 402 _ 18 '_ 498 _ 0 310 18 498 0 6 c)AED excursion 244 458 Envelope loss(gain 2557 2986 2103 2007 12 a) Infiltration 272 73 272 73 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal(lines 6 to 13) 2829 5058 2375 2080 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2829 5058 2375 2080 15 Duct loads 16% 13% 457 663 16% 13% 384 273 Total room load 3286 5722 2759 2352 Air required(cfm) 122 2651 102 1 109 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrOghtsot:t- 2021-Oct-21 11:30:04 A �°^ •.uma Right-Suited Universal 202121.0.08 RSU081 01 Page iWrightsoftHVACNEGA,RODOLFO-GOPHERRIDGE.rup Calc=MJ8 Front Door faces:SE - -wrightsofta Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@A0L.0 0M 1 Room name CLST. BEDROOMS 2 Exposed wall 6.0 ft 25.0 ft 3 Room height 9A ft heaticool 9A It heat/cool 4 Room dimensions 6.0 x 7.0 ft 1.0 x 186.0 It 5 Room area 42.0 ftz 186.0 fP Ty Construction U-value Or HTM Area (it) Load Area (ft?) Load number (BMhV-°F) or perimeter (ft) (Btuh) or perimeter (f) (Btuh) Heat C001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W. I 13A-5ws 6325 he .3.50 1.91 6 0 (Y .. 0 0' 0 0 0 _ 4A5-2ob 0.560 ne 15.68 33.75 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ob 0.560 ne 15.68 33.75 0 0 0 0 4A5-2ob OM ne 15.68 33.75 0 0 0 0 0 0 0 0 11 D _11DO. -- ._ 0.390 ne 10.92 10.34 0 0 0 0 0 0 0 0 w 13A5ocs 0.125 se 3.50 1.91 0 0 0 0 113 113 395 216 t-G 4>A5-lob _ .0.560 se 15.68 25.15 0 0 0, 0 0 -_0 0 0 W 13A5ocs 0.126 - 0 s 350 1.91. ..' t); _ .!) _ _. ... .0 _ 0 .0'_ . 0' 0 �D2 W 13A-5ocs 0.125 sw 3.50 1.91 56 56 197 108 122 107 375 205 4A5-2ob 0.560sw 15.68 25.15 0 0 0 0 15 7 235 377 4A5-2ob 0.560 sw 15.68 25.15 0 0 0 0 0 0 0 0 11 DO- l).390_sw 1022 10.34, ,, 0 0 0 0 0 0 _ 0 0 W i 13A 5ocs &t5 w 350 191 o. 0 0 0 0 0 0 0 W 13ASocs 0.125 nw 350 1.91 0 0 0 0 0 0 0 0 Lt4A5-2ob 0560 nw 15.68 33.75 0 0 0 0 0 0 0 0 4A5-2ovd 0.470 nw 13.16 2829 0 0 0 0 _0 0 0 0 P. 12C-Osw 0.091 - _ 2.55 1.06 0 ._ ,0 0 0' 0 10 _ 0 0 C 16X19-0ml 0.408 - 159 1.13 42 42 67 48 186 186 295 211 F. 22A-4pi.. 0:989"- 27.69' 0.00 42 6 166 0 186I . 25 692 0 6 c)AED excursion -3 222 Envelope loss/gain 430 153 1992 1230 12 a) Infiltration 91 24 377 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal(Iines 6 to 13) 521 177 2370 1561 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 521 177 2370 1561 15 Duct loads 16% 13% 84 23 16% 13% 383 205 Total room load 605 200 2753 1766 Air required(cfm) 22 9 102 82 Calo!�lat!ons approved hyACC-A to meet all requirements of Manual J 8th Ed. "OW wrightsotta 2021-Oct-21 11:30:04 Right-Suite®Universal 2021 21.0.08 RSU08101 Page 4 \Wrightsoft H\AAVEGA,RODOLFO-GOPHER RIDGE.rup Calc=MJB Front Door faces:SE -wrightsofte Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.00M 1 Room name BEDROOM 4 BATH 3 2 Exposed wall 25.0 ft 7.0 ft 3 Room height 9A ft heaUcool 9.4 ft heaUcool 4 Room dimensions 12.0 x 13.0 ft 6D x 11.0 ft 5 Room area 156.0 ftz 66.0 ft' Ty Construction U-value Or HTM Area (ftF) Load Area (W) Load number (Btuh/fP--°F) (BtuhM or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W -` 13A-5acs 0.125 he, 3.50 ' 1.91 113 98 -.342 187 56 52 181 99 4A5-2ob 0.560 ne 15.68 33.16 0 0 0 0 5 0 75 161 4A5-2ob 0.566 ne 15B8 33.75 0 0 0 0 0 % 0 0 4A5-2ob, 0.560 ne 15.68;. 33.75 15 0 235 506 0 IO 0 0 11 D '11D0 0.390 .ne, _10,92 10.34 _- - '0 ._ _ .. 0 0- 0 0 .0 0 0 W 13A 5ocs 0.125 se 3.50 121 122 122 428 234 9 9 33 18 -G 4A5-2ob _ 0.560 se 15.68 25.15 0 0 0 0 0 0 0 0 W 13A s : - 0.125 s; 3s0 . , 1;91 -. ...: 0 .: ' . 0 0 _ 0 0 . "-6 0 0, TE2D 13ASocs 0. sw 3. 1. 0 0 0 0 0 0 0 0 4A5-lob 0.560560 sw 15.6868 25.11 5 0 0 0 0 0 0 0 0 4A5-2ob 0.560 sw 15.68 25.15 0 0 0 0 0 0 0 0 11DO 0290 sw 10.92 10.34 0 __ 0 _ 0, _ . . 0 0 0 0 0 W 13A-150cs .. ` 0.125 .W 350'. 191 0' 0 0 0 0 ''0 0 . 0 W 13A-5ocs 0.125 nw 3.50 191 0 0 0 0 0 6 0 0 4A5-2ob 0.560 nw 15.68 33.75 0 0 0 0 0 0 0 0 4A5-2ovd 0.470"nw _ 13.16 2829 -0 0 0 _ 0 0 0 0 0 P - : 12C-0sw . _ 0.691 . 2.55'.. ._ 06, 0 . 0 0 0 l 0 0 6 0 C 16X19-0m1 0.408 - 1.59 1.13 156 156 247 177 66 66 105 75 F 22A4p1' 0.989 21.69'. '6.� 156: '. 25 692 0 66 7 194 A 6 c)AED excursion -21 5 Envelope loss/gain 1945 1083 587 347 12 a) Infiltration 377 101 106 28 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(Iines 6to 13) 2322 1414 692 375 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2322 1414 692 375 15 Ductloads 16% 13% 375 185 16% 13% 112 49 Total room load 2697 1600 804 424 Air required(cfm) 100 741 30 20 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A Ad- 2021-Oct-2111M:04 Right-Suite®Universal 2021 21.0.08RSU08101 Page 5 SWrightsoft HVACIVEGA,RODOLFO-GOPHER RIDGE.rup Calc=MJB Front Door faces:SE _ > O1 > CA NAWN> r l �� C7WCrr W 5 afl m fII--jtI-. 'c M�� � r G 0oyyy 3 �n I1TIL :C7 047 333w$ m , Fa ca $6i5a fD 6f m o o mn�CD rr �3 o_ x OI HMOKH �Aa pAN Wa— oram c5p3 a1. r°n ctX n ^9oY' 19: c o >w_m mO N N W� L' 0OO 000 O~ O •8 Q S OC O N D C° 1-0o000000000000000000; m o �y(A OG N NN NN N N Cl) � > 0 _ r+ _ -.. O N•N N NON N. X2 tv m� f �. g N m m m m c'o m coo, a D O m C O CD N a :+.NtW L71 W WONNW WN N W WON N . ' fD .. (O 18 9((��77 S °o N . ° gm O.»co +0(N71N> CNTI pp bb (W� ww O a`o� ,."• OWN�CVT�� �P.NU���N�AfJ11NN CD ;1 C D CD p� r+ - " �� CD CD r�a� o N - Oo.00 O10 OO:ti0AP 00W V000000' �' O A D Z m o 8 �• .. �DOf.�000'V10NOW V-O OD00000 x �W m CD m &j >� 8 i w � � rn (w� > (o�y NN f7�0000 O ON 00OOO.WOOO�IW ON00000 -. 0 °O N W N ° OW OOA N OAZ0 00N ;jO'000 0� L p� D Q- o O � �00000.0000000000000 �_ O A K W , o ON.b00000000:010000000 1 x C N S >o N ' b w2 wc"°000 oo om00000.0000000000O.o a g o $ rn6 WS -4rn000 rn Oo 00 i o,04000000000.0000O'000 �{+wrightsoft Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS a,,OL.COM 1 • Room name M.BATH LAUNDRY 2 Exposed wall 6.0 ft 15.0 ft 3 Room height 9A ft heat/cool 9A ft heaUcool 4 Room dimensions 1.0 x 121.0 ft 1 D x 69.0 it 5 Room area 121 D 8z 69.0 ftz Ty Construction U-value Or HTM Area (fF) Load Area (ftF) Load number (BtuhgF--°F) (Btuhlff� or perimeter (it) (Btuh) or perimeter (tq (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 w 13A-5ocs, 0.125 ne 'Ub 1M 0 0 0 0 141 141 403 276 4A5-2ob 0.560 ne 15.68' 33.75 0 0 0 .0 0 0 0 0 AA5-2ob OM ne 15.68 3175 0 0,4A5-2ob 0.560 ne 15.683175 0 0 0 0 0 0 0. 0 0 � 0 0 0 0 0 11 D 11D0 _ 0.390 .ne 10.92_ 10.34 0 _. _ 0 0 0 0 0 0 0 � 13A 5ocs 0.125 se 3.50 1.91 0 0 0 0 0 0 0 0 G 4A5-2ob _ 0.560 se 15.68 _ 25.15 0 0 0 0 0 0 0 0 W; . .: 13A 5ocs ,.. -..0.125 s - 350 y 191' .: 0 0 0 0 0 _0 0 0 w 13ASocs 0.125 sw 3.50 1 D1 0 0 0 0 0 0 0 0 4A5-20b 0.560 sw 15.68 25.15 0 0 0 0 0 0 0 0 4A5-2ob 0.560 sw 15.68 25.15 0 0 0 0 0 0 0 0 D 11 DO 0.390 sw 10.92 10.34 0 0 0 _ 0 0 0 0 0 W 13AS6cs 0.125 _w 350 1:91 . 0 0 0.. 0 .. _ 0-- 0, 0- 0 W 13A-5ocs 0.125 nw 350 121 0 0 0 0 0 0 0 0 4A5-2ob 0560 nw 15.68 33.75 0 0 0 0 0 0 0 0 4A5-2ovd OA70 nw 13.16 2829 0 0 0 0 0 0 0 0 P 12C-Osw 0,091 '- . 2.55 1`.06, 56 56: _" 144 _ 60 0 0 0 0 C 16X19-Oml 0.408 - 1.59• 1.13. 121 121 192 137 69 - 69 109 78 F _ 22A-tpl 0.089 21M ODD 121 '6 _166 0 ,_ 60 15 415 0 6 c)AED excursion -3 -6 Envelope loss/gain 502 194 1018 342 12 a) Infiltration 0 0 226 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(Iines 6to 13) 502 194 1245 403 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 502 194 1245 403 15 Ductloads 16% 13% 81 25 16% 13% 201 53 Total room load 583 219 1446 455 Air required(cfm) 22 101 54 21 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft� 2021-Oct-21 11:30:04 A u ^°- ^• Right-Suite®Universal 202121.0.08 RSU08101 Page 7 \Wrightsoft HVAQVEGA,RODOLFO-GOPHER RIDGE.rup Calc=MJ8 Front Door faces:SE - -wrightsofr Right-M Worksheet Job. Entire House Date: By: QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-466-6799 Email:QUICKCALCS@AOL.COM 1 Room name OFFICE 2 Exposed wall 32.0 It 3 Room height 9A It heat/cool 4 Room dimensions 11.0 x 10.0 It 5 Room area 110.0 fe Ty Construction U-value Or HTM Area (tt) Load Area Load number (BtuhllF-°F) (BtuW or perimeter (10 (Btuh) or perimeter Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W. .. `13A-5ocs._ 0.125 ne 3.50 lb! 1O 103.. . 3 ._ .. 1§ . �--G 4A5 lob OS60 rte '15M' 33!76 0 0 0 0 4A5-2ob' 0.560 ne 15.68 33.75 0 0 0 D LLFF----CG 4A5-2ob 0.560 he 15.68 33.75 0 0 0 0 11 D_11 DO. ._. ..._- 0.390 rie- 10.92 10.34 0-- , . 0 0 0 fit/ 13A-5ocs 0.125 se 3.50 1.91 0 0 0 0 L-G 4A5-2ob _ 0.560 se 15.68 25.15 0 0 0 0 W _ 13A-5ocs ...._ 0.125 s 356 1,91:. . 0. 0._ 6. . 0 13A5ocs 0.125 sw 3.50 1.91 D 0 0 D 4A5-2ob 0.560 sw 15.68 25.15 0 0 0 0 4A5-2ob 0.560 sw 15.68 25.15 0 0 0 0 D 11DO_ 0.3M sw, „ 10.92 10.34- 0 0 0 0 W'. 13Afocs 0.125 ,w 350, 101. 0 0 O :U-.. . W 13A-5ocs 0.125 nw 3.50 1.91 94 64 224 122 4A5-2ob OM nw 15.68 33.75 30 0 470 1012 4A5.2ovd 0.470 nw 13.16 2829_. 0 0 0- ..0 P 12C-0sw 6.091' - .. 2.56., 1.06 103 •103 - 263 109 , C 16X19-Oml 0.408 - 1.59 1.13 110 110 174 125 F 22A-tpl 0.989 = ' 27.69, 0.60 110 32 . 886 0, 6 c)AED excursion 397 Envelope loss/gain 2380 1963 12 a) Infiltration 317 85 b) Roomventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 2697 2048 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2697 2048 15 Duct loads 16% 13% 436 269 Total room load 3133 2317 Air required(cfm) 116 107 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrQgl�tsoTt° 2021-Oct-21 11:30:04 . A �•w•� -w• Right-Suite®Universal 202121.0.08 RSU08101 Page 8 ...1Wrightsoft HVAC\VEGA,RODOLFO-GOPHER RIDGE.rup Calc=MJ8 Front Door faces:SE ® Duct System Summary Job: - wrightsoft Y Date: Entire House By: QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL 34946 Phone:772-4W-6799 Email:QUICKCALCS@AOL.ODM Project • • For: RODOLFO VEGA 960 GOPHER RIDGE,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.28 in H2O 0.28 in H2O Available static pressure 0.22 in H2O 0.22 in H2O Supply/return available pressure 0.110/0.110 in H2O 0.110/0.110 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual air flow 1133 cfm 1133 cfm Total effective length(TEL) 200 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat Ln(ft) Ln(ft) Trunk BATH 2 h 754 28 25 0.080 5.0 Ox 0 VIFx 61.4 130.0 st2 BATH h 804 30 20 0.080 5.0 Ox 0 VIFx 38.2 110.0 st1 BEDROOM2 h 2903, 107 77 0.080 8.0 Ox 0 VIFx 55.2 130.0 st2 BEDROOM3 h 2753 102 82 0.080 8.0 Ox 0 VIFx 47.7 110.0 st1 BEDROOM 4 h 2697 100 74 0.080 7.0 Ox 0 VIFx 47.0 110.0 st1 OLST h 605 22 9 0.080 4.0 Ox 0 VIFx 44.8 110.0 st1 DINIGXITCHEN c 2861 61 132 0.080 8.0 Ox 0 VIFx 47.4 130.0 st2 DINIGXITCHEN-A c 2861 61 132 0.080 8.0 Ox 0 VIFx 35.0 110.0 st1 FAMILY ROOM c 4251 183 197 0.080 10.0 Ox 0 VIFx 70.3 130.0 st2 LAUNDRY h 1446 54 21 0.080 6.0 Ox 0 VIFx 17.0 70.0 LIVING ROOM c 2352 102 109 0.080 8.0 Ox 0 VIFx 39.0 110.0 st1 M.BATH h 583 22 10 0.080 4.0 Ox 0 VIFx 6.3 70.0 MASTERBEDROOM h 3845 142 134 0.080 8.0 Ox 0 VIFx 18.4 70.0 OFFICE h 3133 116 107 0.080 8.0 Ox 0 VIFx 5.4 70.0 WIC h 92 3 3 0.080 4.0 Ox 0 VIFx 12.0 90.0 st1 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 799 860 0.080 616 16.0 0 x 0 VinlFbc st2 PeakAVF 379 431 0.080 549 12.0 0 x 0 VinlFbc st1 Bold"talic values have been manually overridden wrightsoft, 2021-Oct-21 1130:05 .� .•,� .,«.�, RightSuiteOunwrsal202121.0.08RSU08101 Pagel ...\Wdghtsoft H\ACIVEGA,RODOLFO-GOPHER RIDGE.rup Calc=MJ8 Front Door faces:SE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mal Trunk rb1 Ox 0 1133 1133 0 0 0 0 Ox 0 VIFx -i�i- wrightsoft" 2021-oa-2111:30:05 RlghtSulte®UnNersai 202121.DA8 RSU08101 Page 2 �!� ...\WrightsoftRAC1VEGA,RODOLFO-GOPHERRIDGE.rup CaIo=MJ8 Front Door faces:SE