Loading...
HomeMy WebLinkAboutapproved, RevisionsOFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # 2012-0540 RECEIPT # - Map. v -D PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION v �� 7 2300 VIRGINIA AVENUE NOID FORT PIERCE, FL 34982-5652 St. Lucie County f _ (772) 462-1553 Permitting APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 4003 Ave. 0 Fort Pierce FL 34947 DETAILED DESCRIPTION OF PROJECT REVISIONS: Engineer's report and drawing for mullions and concealed work, per inspection comments. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC 046091 ST. LUCIE CO CERT. #: BUSINESS NAME: STORM TIGHT WINDOWS QUALIFIERS NAME: ALPHONSE CAMPANELLI , ADDRESS: 500 SW 12th.AVENUE CITY: DEERFIELD BEACH STATE: FL ZIP: 33442 PHONE (DAYTIME): (561) 420-02071 FAX: (754) 227-7891 OWNER/BUILDER INFORMATION: NAME: RICARDO & KIMBERLY PELLOT ADDRESS: 4003 Ave. O CITY: Fort Pierce STATE: FL ZIP: 34947 PHONE (DAYTIME: (772) 216-2267 FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC. 9123109 Revised 06130117 4"x 4" WOOD BEAM ^ . (� Tll\TAT (EXISTING)G) •` % J _ � 4"x 1"x 1/4"6061-T6 ALUMINUM TUBE MULLION WITH INSERTS. ATTACH -' AT TOP W/ 4@#14x3"WOOD SCREWS ATTACH AT BOTTOM W/4@1/4"x3 1/4" TAPCONS. NEW WINDOWS NEW WINDOWS NEW WINDOWS CONCRETE SILL (EXISTING) _ ST. LUCIE COUNTY DUILDING DIVISION REVIEWED FOR CO 5�16 CE . REVIEWED BY DATE i PLANS AND PERMIT I 041 KEPT ON OR u ST BE NO INSPECTION WILL BE MADE —.1 200" NEW WINDOWS WITH VERTICAL MULLIONS r A --' k• t '� 1 IA Engineering and Designs, Inc. Consulting Engineers 8427 Siciliano Street Boynton Beach, FL 33472 Telephone: (954) 984-4646 Fax: (561) 413-3109 PE #28376, CA #30113 SI #1121 Pellot Residence 4003 Avenue 0 Fort Pierce, Florida 34947 Door and Window Wind Loads (ASCE 7-16) Wind Velocity (mph) 160 2020 Florida Building Code Section 1620 Importance Category II Mean Height of Roof (ft) 12 Use ASCE 7-16, for h<=60ft only Length of Short Side (ft) 14.67 Building enclosure Enclosed Slope of roof (Degrees) 18.435493 Negative internal pressure -0.18 Positive internal pressure 0.18 C Alpha 9.5 Zg 900 Exposure coefficient (KZ) 0.85 Kz (from ASCE 7-16,z>=15 ft) Directional coefficient (Kd) 0.85 Velocity Pressure (psf) 47.29 qz=.00256KZV2IKd (Kzt= 1.0) Pdesign=P*0.60 as required by ASCE 7-16 Window Number 1 1 2 2 3 3 Distance from Corner to End of Type 5 Area (ft) 3 Window within Type 5 area TRUE FALSE TRUE FALSE TRUE FALSE Window/Door Height (ft) 5.875 5.875 5.875 5.875 5.875 5.875 Window/Door Width (ft) 5.4444444 5.4444444 5.4444444 5.4444444 5.4444444 5.4444444 Window/Door Area 31.99 31.99 31.99 31.99 31.99 31.99 Positive GCp 0.911 0.911 0.911 0.911 0.911 0.911 Adjusted Positive GCp 0.911 0.911 0.911 0.911 0.911 0.911 GCp -1.222 -1.011 -1.222 -1.011 -1.222 -1.011 P.E. #28371 NOV i p, Pellot Residence 4003 Avenue 0 Fort Pierce, Florida 34947 Span #1= 2 FT DL= Span #2= 2 FT DL= Wall Hgt= 0 FT DL= i a IA Engineering and Designs. Inc. 8427 Siciliano Street Boynton Beach, Florida 33472 Tel:(954) 984-4646 FAX:(561) 413-3109 PE#28376, CA#30113, SI#1121 ANALYSIS OF WOOD BEAMS 25 PSF LL= 30 PSF TL= 25 PSF LL= 30 PSF TL= 0 PSF LL= 0 PSF TL= Total Beam Load= Try= 1 @ 4 X 4 LOAD FACTOR= 1 Fb= 1500 PSI DER ALLOW (Ud)= 240 E= 1600000 PSI UNIFORM LOADING: OVERHANG L= 2 FT Beam Lg= 5.44 FT Mmaxl= 304.3 FT- # Mmax= 304.3 FT-# V1= 339.6 # V3=R1= 258.8 # Vmax= 339.6 # 55 P/FT BEAM 55 P/FT BEAM 0 P/FT BEAM 110 P/FT BEAM GRADE= 2 Fs= 90 PSI Mmax2= 220.0 FT- # V2= 220.0 # R2= 559.641 # Members= 1 X 3.5 X 3.5 Bending Check: Shear Check: ` 4 Deflection Check: USE: 1 @ 4 X 4 GRADE= 2 0 1 fb= 511.1 PSI Fb= 1500.0 PSI BENDING IS OK fs= 41.6 PSI Fs= 90 PSI SHEAR IS OK delta= 0.1083IN Udelta= 603 DEFLECTION IS OK P.E. #28376 i� NOV 12 IA11 r IA Engineering and Designs, Inc. Consulting Engineers 8427 Siciliano Street Boynton Beach, FL 33472 FAX:(561)413-3109 TEL:(954)984-4646 PE#28376,CA#30113,S1#1121 WINDOW AND DOOR MULLION DESIGN CLIENT: Pellot Residence 40030Avenue O Fort Pierce, Florida 34947 OPENING DIMENSION (1): WIDTH: 65.28 IN. X HEIGHT: 70.5 IN. OPENING DIMENSION (2): WIDTH: 65.28 IN. X HEIGHT: 70.5 IN. MULL DIRECTION VERTICAL (VERTICAL OR HORIZONTAL) MULLION LENGTI 70.5 IN. DESIGN PRESSURE (1): -39.77 PSF DESIGN PRESSURE (2): PRESSURE LOAD ON MULLION: W= 216.3 PLF MAXIMUM MOMENT IN MULLION: M= 933.4 FT -LB MAXIMUM SHEAR IN MULLION: V= 635.5 LB END ATTACHMENT IS SHEAR OR TENSION TO WALL: SHEAR TRY SPECIAL HEIGHT I= 0 INA4 SECTION: # OF WEBS= 0 x 0 S= 0 INA3 HEIGHT WIDTH THICKNESS TRY SECTION: TUBE 4 x 1 x 0.25 1= 3.551N^4 S= 1.77INA3 LGTH= 4IN THK= 0.250IN MATERIAL: ALUMINUM 6061-T6 Fb= 19000 PSI Fs= 12000 PSI Udel= 360 fb= 6316 PSI OK FOR BENDING fs= 318 PSI OK FOR SHEAR del= 0.162 IN OK FOR DEFLECTI E= 10100000 PSI Udel= 435 USE: TUBE 4 x 1 x 0.25 1 -39.77 PSF P.E. #28376 CLIENT: Pellot Residence 40030Avenue O Fort Pierce, Florida 34947 FASTEN WITH: #14 DIA. WOOD SCREWS NUMBER OF FASTENERS/SIDE= 3 FASTEN WITH: 1/4" TAPCONS NUMBER OF FASTENERS/SIDE= 2 IA Engineering and Designs, Inc. Consulting Engineers 8427 Siciliano Street Boynton Beach, FL 33472 FAX:(561)413-3109 TEL:(954)984-4646 PE#28376,CA#30113,SI#1121 Ps= 232 LB/FASTENER #14 DIA. WOOD SCREWS 1/4" TAPCONS Ps= 456.5 LB/FASTENER P.E. #28376