BLOWER DOOR TEST FORM
House Infiltration T st Certification
Prescriptive and Pe ormance Method
Date: 10/25/2021 Permi #: 20120410
Contractor: RON RAYMOND CONSTRUCTION
Job Address: 2422 OAK DRIVE FORT PIERCE
Construction: ( X ) New Construction—Complete ( ) Existing—After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM($0)= 2175 Test Date: OCTOBER 25, 2021
Volume= 22503.9
ACH (50) =CFM (50)x 60/Volume= 5.8 Mechanical Ventilation required less than 3 ACH
Passing results must be&ACH (50)or less (X) Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified)as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w.g. (50 Pascals . Testing shall be conducted by either individuals as defined in
Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or(i)or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC,Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Sec ion R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: ECOINNOVATIVE Address: 10570 S US HWY 1,STE 300 PORT ST LUCIE, FL 34952
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
g Kathleen Connolly ti,Digitally sign by Kathleen Connolly
Signature: y ;:'Date:2021.19.2716:19:24-04'00'
Printed Name: kathleen connolly
License/Certification#: 5060036