Loading...
HomeMy WebLinkAboutAPPROVED FPA Impact Door7/7/2021 i I BCIS Home Log In User Registration Hot TopIcs bpr L: 4Product Approval USER: Public User Florida Building Code Online ti t� Il �It Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map finks Search PrAict ARrlroval Menu a E=oct or Appb atlun 5corN Apphcatmn List a Application 6etarl FL # FL5979-R18 ` Application Type PP YP Editorial Change Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Simonton/Ply Gem Windows Address/Phone/Email 5020 Weston Parkway Suite 300 Cary, NC 27513 (800)542-9118 Ext413596 luanne.harris@cornerstone-bb.com Authorized Signature Luanne Harris luanne.harris@comerstone-bb.com Technical Representative Luanne Harris Address/Phone/Email 1 Cochrane Ave Pennsboro, WV 2641S (614)532-3596 luanne.harris@simonton.com Quality Assurance Representative AAMA Address/Phone/Email 1827 Walden Office Square Suite 550 Schaumburg, IL 60173 (847) 303-5664 webm aster@aama net.org Category Exterior Doors Subcategory Sliding Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By American Architectural Manufacturers Association Referenced Standard and Year (of Standard) Standard year AAMA 506 2016 AAMA/WDMA/CSA 101/I.5.2/A440 2008 ASTM E 1886 2013 ASTM E 1996 2014 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect 171-5979 RIB EgWi FL5979 Equivalency_pdf https:l/www.noridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvHz5YE31uuVSlgNPiQf85sAP2d0h4KM8W6ibqAoavO3A%3d%3d 112 7n/2021 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option A 06/04/2021 06/04/2021 06/08/2021 Summary of Products FL # Model, Number or Name 5979.1-- Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: 95x80 - Missile Impact Rating: C 5979.2 :11-11 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: 71x79, 71x95, 95x79, 95x95, 107x79, 107x95, 143x79, 143x95 - Missile impact Rating: D Description _ --- - - ProRnlsh Brickmould w/SafePoint Storm, Contemporary Vinyl 2-Panel Sliding Patio Door Certffi floe Agency Certificate FL5g79 R18 A ne-nc 7p n I ��� --- >df Quallty Assurance Contract Expiration Date 01/30/2022 Installation Instructions FL5979 R18 II IN0548-R2 pdf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL5979�nort-IN0548-97 gdf Created by Independent Third Party: Yes StormBreaker Plus, 8000, PerfeXion Impact 2-Panel & 3-Panel Sliding Patio Door Certification Agency Certificate _-- _— - - - --- _ FL5979 RIB C CAC 11-11 3P 5 D lmpaq-jQZ&7Q R O OQ FL5979 R18 C CAC 11-11 3P SGD Impact 107x95 RSO.pdf FL5979 R18 C CAC 51-11 3P SGD Impact 143x79 RSO.pdf FL5979 R18 C LAC 11-11 3PSGD Impact 143x95 R PGSO.gdf Quality Assurance Contract Expiration Date 07/09/2021 Installation Instructions FL5979 R18 II IN0371-R7 df Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports— - _-- F 97 R18 AE valR Dort-IN0371-R7 oilf Created by Independent Third Party: Yes conductUs:: 2601 Blair stone Raae Tnllanas F i]399 Poore: 850487-1824 The state of Fbrlde Is an AVEW employer. Q&,I ht 200>-2013 state of FI tl Pdvaty statement :: Access pile, Sbt-mrM :: Refund suddabove Under Florida law, email addresses are public..Ms. if you do not want your e-mall address released in response to a Public -recants request, do not "ad electronic mad to ale entby. Innea , contact We state by phone or by tradidonal mail. If you have any questions, please Contest 850.487.1395.'Pursuant to Sedbn 455.275(/), Florida Statutes, eXedows October 1, 2012, IiCaMew, licensed under chapter 455, F.S. must PmAde Hie Department with, an email address xmey have one. The deals provided may be used for .1rdi l mmmunxetion wid, the Noumea. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. ro detertnlne x you are a howeea under chapter 455, F.S., please dick berc , product Approval Aegyta: ®NU® KE® Credit Card Safe hfps:l/wvrw.floridabuilding.org/pr/pr_app_Otl.aspx?param=wGEVXQVADgvHz5YE3[UuVS1 gNPIQf85SAP2dOh4KM8W6ibgAoavO3A%3d%3d 212 (Validates / Operations Administrator) Simonton Windows 1 Cochrane Dr. Pennsboro, WV 26415 Attn: Tina Sees& AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMAAVDMAICSA 10111.5.2/A440-08 R-PG50-2724x2013 (107x79)SD AAMA 506 Missile Level: D CPD SERIES MODEL & COMPANY AND CODE Rating: +501.50, 107x79 NO. PRODUCT MAXIMUM SIZE TESTED Wind Zone: 4 Rating above conforms DESCRIPTION 11-11 SGD Simonton Windows to the requirements of: (PVC)(OXO)(OG) FRAME fmml (mm AN PANEL fmml 2724 x 013 x 1943 943 Code: SIM ASTM E1886 96n (INS TEMPIPVB LAM GL) and E1996 (MODIF)(REINF)(ASTM) (2724 x (918 x 2. This Certification will expire July 9, 2021 (extended from July 9, 2016 per AAMA 103.15) and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Structural Test & Report By: Architectural Testing, Inc. Report No: C0842.09.109.47 Date of Report: July 30, 2012 (Revised August 2, 2012) Date: March 28, 2016 Cc: AAMA JGS ACP-14 (Rev. 1/11) Missile Impact Test & Report By: Architectural Testing, Inc. Report No: C0843.01-109-47 Date of Report: September 27, 2012 Validated for Certification 'h' A ocl ted Laboratories, Inc. Authorized for Certification T� AmeritlJ Architectural Manufacturers Association (Validator / Operations Administrator) Simonton Windows 1 Cochrane Dr. Pennsboro, WV 26415 Attn: Tina Seese AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based successful completion of tests, and the reporting to the Administrator of the results of tests. accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMAIWDMAICSA 101/1.S.2/A440-08 R-PG50.2724x2419 (107x95)SD AAMA 506 COMPANY AND CODE Missile Level: D CPD SERIES MODEL & PRODUCT Rating: +50/S0, 107x95 NO. MAXIMUM SIZE TESTED Wind Zone: 4 Rating above conforms DESCRIPTION 11-11 SGD Simonton Windows to the requirements of: (PVC)(OXO)(OG) FRAME (mm1 AN PANEL ANEL Im (m ml 4724 x 916 x 346 Code: SIM ASTM E1886 2534 (INS TEMP/PVB LAM GL) and E1996 (MODIF)(REINF)(ASTM) (8'11" x 7'11") (3'0" x 7'811) 2. This Certification vnll expire July 25, 2021 (extended from July 25, 2016 per AAMA 103-15) and requires validation unfil then by continued listing in the current AAMA Certified Products Directory. 3. Structural Test & Report By: Element Materials Technology Report No: ESP010622P-5 Date of Report: August 10, 2012 Date: March 28, 2016 Cc: AAMA JGS ACP-14 (Rev. 1/11) Missile Impact Test & Report By: Element Materials Technology Report No: ESP010622P-6 Date of Report: August 10, 2012 Validated for Certification 'h' A oci ted Laboratories, Inc. Authorized for Certification AmerikA Architectural Manufacturers Association (Validator / Operations Administrator) Simonton Windows 1 Cochrane Dr. Pennsboro, WV 26415 Attn: Tina Seese AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMANVDMAICSA 101/1.S.2/A440A8 R-PG50-3639x2013(143x79)SD AAMA 506 Missile Level: D CPD SERIES MODEL & COMPANY AND CODE Rating: +50/-50, 143x79 NO. PRODUCT MAXIMUM SIZE TESTED Wind Zone: 4 Rating above conforms DESCRIPTION 11.11 SGD Simonton Windows to the requirements of: (PVC)(OXO)(OG) FRAME (mml PANEL (mml 3639 x 2013 1245 x 1934 Code: SIM E9666 10223 (INS TE LAM GL) and E and E1996 (MODIF)(REINF)(ASTM) )(REIN (11'11" x 6'7") (4'1" x 6'4") 2. This Certification will expire October 31. 2021 (extended from October 31, 2016 per AAMA 103-15) and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Structural Test & Report By: Architectural Testing, Inc. Report No: C3517.01.501-47 Date of Report: January 11, 2013 Date: May 26, 2016 Cc: AAMA JGS ACP-14 (Rev. 1/11) Missile Impact Test & Report By: Architectural Testing, Inc. Report No: C4265.01.10947 Date of Report: January 21, 2013 Validated for Certification ,h, oci ted Laboratories, Inc. Authorized for Certification AmerNA Architectural Manufacturers Association A•L•1 (Validates / Operations Administrator) Simonton Windows 1 Cochrane Dr. Pennsboro, WV 26415 Attn: Tina Seese AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION This authorization is based on the successful completion of tests. and the reporting to the AAMA Validator of the results of the tests by an AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED 71 AAMANVDMA/CSA 101B.S.2/A440-08 R-PG50-3639x2419 (143x95)-SD AAMA 506 COMPANY AND CODE Missile Level: D Rating: +50/30, 143x95 Wind Zone: 4 SERIES MODEL & PRODUCTF DESCRIPTION UM SIZE TESTED JNO SGD (INS TEMPI SGP LAM TEMP GL)11 (M ODIF) (RE IN F)(ASTM) m) 19 ") PANEL (mml Simonton Windows Code: SIM Rating above conforms11-11 to the requirements of:(PVC)(OXO)(OG) ASTM E1S86 and E1996 1222 x 2350 (4'0" x 7'9") This Certification will expire March 11, 2022 (extended from March 11, 2017 per AAMA 103-15) and requires validation until then by continued listing in the current AAMA Certified Products Directory. Structural Test & Report By: Architectural Testing, Inc. Report No: C6575.01.501-47 Date of Report: April 3, 2013 JGS/JTS ACP-14 (Rev. 6/16) Missile Impact Test & Report By: Architectural Testing, Inc. Report No: C6573.01-109-47 Date of Report: April 3, 2013 Evaluated for Certification: October 7, 2016 /J A( ted Laboratories. Inc. Authorized for Certification: October 7, 2016 America rchitectural Manufacturers Association W a BAyr 9 g-M Ni $gg€ n� Z FR Z N W o a a o o a a o x a a a N NW.=�Am m�ZlO1.�mm N K x N ei WU m \ • m m N N i- I N n n \ \ S - W W n n r � 4 4 p F Uo t pz F F po[� F VUI �7bU by j b e e N NWN� J z o w ¢ o c w z z _i 21 n a �-mz 2 z N o_ NCO WY�gIW ?r1¢UW N p3a Zp ynj� C/rl z cmim U S�N�%Vb mm B< al U O W LL N N w O LL gg o 31$2 iFaWi�g9 EiNo < i a u_ oi N z N " O N S N J W u F W ¢Z j J O U O l X O C t-ceWLL:g<o Er : N =Y� S Z W¢ V 2 ym, p 2 ¢ a V W gg11 % O Z way W E 1- J Y S W O H N E O U � W O Yi F <_ W W 9 z C y j W Z q j V W J n< y yl " m C W m G j O 6 Z <a¢s N�� wazg o myy}}in00% nS F$ wosi�s Wgr nNs< �+WoF 09 t2_ mf W2� of m<z 'a Wwo m'W' .�f" i Gyo 3 �d�mae5-`i¢'S 3'¢ ���oo�y� z�W ; ooroiLLa Fz Iygo W �Iru�N y J a afmg z NIO-C aio1 <f2^ gpw Fr z je�o,o a wiam€I'u3� 1�;, asLL aw<a 12.101 a¢i o l' =om U n n o �ww:W�dw a_N ai '`W'"'WxgWzZ ge. a W F s i w o d a .o. o y z o 9 8 i P r p o i < a J w a3 �'r L""' a^ z.oW �¢�_� o ? a a z N C W F U 0 0^ 2 N Z_Cs Nn < p ¢ O aO = O 6¢ OF C W 2 Z W i J e< 2 N Z O y n .J a i ¢N t a w w F- >< 4`0' ' z FFu<QQ4wo?3Ear.o+`o'In"3 =fnrS�l¢o`x4oa��a3urp�x z ..1,! .�, gy7r .� (?•| !� .:|( |, |ED ||||| 0 ..: or• ;..... o 0- i ! § " ® ( a. m F U /EDU � J % ` | 7 | ' L z 2| fit R ~� / O •�, ! ! � ) � ]§ r,� % /\c 0 oa ' b 3 | w . | U 2 al u §a. h| } | z X z¥ . « � �w /~w " � 5 X. Yp & a „ 09 4�S{ <}j a e� X X Z K G 2 K cz- 0 $g rctuw �rc� i S 4 s w u p a i 2 }v0iN ty[ogy � x � e o IIL7Jl�IIJGI� N a xO O g88 3p5 rc� x x a px ♦ Old �'''�_ 39k ` �� p{�b8. I �XgX, CiN!{ • + z c o s g a N 3 3 a fill ciz€g E „xa 'aw YY s a�oa t8 xry S Y13m3 "3 AS _ t' a RW i �W „ URNER ENGINEERING & CONSULTING, INC. 2428 Old Natchez Trace Trl. Camden, TN 38320 Ph.941-380-1574 FBPE C.O.A.#29779 Evaluation Report IN0371-R7 December 8, 2020 Product Description: Sliding Glass Door Series 11-11, XO, OX, or OXO configurations Manufacturer: Simonton Windows, 1 Cochrane Ave., Pennsboro, WV Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule 61 G20-3.005 (4). This product complies with the requirements of the 7s' Edition (2020) Florida Building Code outside the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 2428 Old Natchez Tic Trl, Camden, TN 2) Installation drawing IN0371-117, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports C0842.01-109-47-R1, C0843.01-109-47-r0, C3517.01-501-47-r0, C4265.01- 109-47-r0, C6573.01-109-47-r0, C6575.01-10947-rO, from Architectural Testing, Inc., Springdale and York, PA, and ESP010622P-5 and ESP010622P-6, by Element Materials Technology, Wausau, WI, with testing performed: AAMA/WDMA/CSA 101/I.S.2/A440- 05/08, ASTM E1886-05, and ASTM E1996-09 4) Supplemental Calculations to support IN0371-R7, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to installation drawing IN0371-R7. Limitations of Use: This product: • May be used in the configurations, DP, product sizes, and with glazing as indicated in IN0371-R7 • Is large missile impact resistant (missile level D, wind zone 4) and does not require the use of shutters in windbome debris regions • May not be used in the High Velocity Hurricane Zone • Requires Eastman (Solutia) Saflex HP PVB interlayer in laminated glass • Requires white SiroEx, Inc. PVC extrusions with current listing as an AAMA Certified Profile Licensee under AAMA 303 Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Simonton Windows or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. Lucas Turner =�, No.58201 } ;�� 2020.12.08 =0i * =� 12/8/2020 _ 14:36:35-06'00' i STATE � Z' Lucas A. Turner, P.E. FL PE #58201