HomeMy WebLinkAboutAPPROVED, 11505 Willis Rd Permit InfoS �r, LL! cLL
C-)�-�
r
ST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Low Slope Application
Prescriptive BUR-RAS 150
Required Sections of
the Permit Application
Form
A, B C
A, B, C
Attachments Required
See List Below
1,2,3,45,6,7
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,8,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs
A, B, D
1,2,3,4,5,6,7
Wood Shingles and '
A, B, D
` 12,4,5,6,7
Shakes
Other •
As Applicable
, , ,7 J
ATTACHMENTS REQUIRED As APPlicablej:
1. Fire I"ctory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Ap cable Detail Drawingj -.• f
• ... •ram..._.--r-�
3. Design Calculations per Cha er or If applicable, RA 127 or RAS 128
4 Other Component of Product Ajftal`; "-
5. Municipal Permit Application
I
6. Owners !Notification for Roofing Considerations (Reroofing Only)
7 Any Required Roof Testing/Calculation Documentation
f arms Itog11nW111621 aev F alb 13, X21
ST. LUCIE WORKS
Section A (General Information)
Master Permit No.
Process No.
Contractors Name
�[ {
Y\Q License a
Job Address
ROOF CATEGORY
❑ Low Slope
❑ Mechanically Fastened Tile
❑ Mortar/Adhesive Set Tiles
❑ Asphaltic Shingles
❑ Metal Panel/Shingles
❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE
❑ New roof
❑ Repair ❑ Maintenance
❑ Reroofing Q Recovering
p ROOF SYSTEM INFORMATION p��
Low Slope Roof Area (SF) _ p1 _ Steep Sloped Roof Area (SF) L D ,\ v D Total (SF) 2 Q" 1
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
1
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer
Notice of Acceptance Number. FL
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
81.7
4 Zone 1:33—Zone 2e:"t'9LZone 2n,l�gone 2ra` -one 3e: Zone 3r:
Deck Type: S/j Plywood
Roof Slope:
Type Underlayment: LSelf Adhesive Underlayment A QC -[L�ff Al f-
- -
Insulation: NIA
Fire Barrier: N1A
!Ridge fentdation? Fastener Type & Spacing: 6 Nails PerShingle - 1 114" Coil N Is
Adhesive Type: Bituman Tar
Type Gap Sheet NIA
r —
Mean Roof Heigh: 15 ft Roof Covering Dimensional Asphault Shingles
Type & Size Drip 2" x2" Galy. Steel
Edge:
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
Of a component is not used, identify as ''NA")
System Manufacturer: PolyglasS
Product Ap prova I No.: FL 1654 -
Design Wind Pressures, From RAS 128 Or Calculations:
53.32 -53.3 -74.4 -95.8
Zone 1': , one 1: Zone 2: Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:_Plywood
Gauge Thickness: 5/8
Slope: 1-112 112
Surfacing: white Granular Surfaces
Fastener Spacing for Anchor/Base Sheet Attachmert:
Zone 1':_" oc @ Lap, # Rows @ oc
Zone 1:_" oc @ Lap, # Rows _ @ oc
Zone 2:_ _" oc @ Lap, # Rows — 6 �' oc
Zone 3:---" oc @ Lap, # Rows__ Q oc
Number of Fasteners Per Insulation Board:
Zone 1': Zone 1• Zone 2 Zone 3
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc_
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base SheetPollass s] & No. of Ply(s): y9 SA-V & 1 -
Base Sheet Fastener/Bonding Material:
Self -Adhesive
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material
Top Ply:
Top Ply Fastener/Bonding Material
Self-Adhesrve Tb r Lh p o11r t d-