Loading...
HomeMy WebLinkAboutENCODES & MJ(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HOMECRETE - ROBINSON 2 Builder Name: HOMECRETE HOMES Street: 5403 DEER RUN DR. Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: ROBINSON RES. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41580.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=6.5 1276.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 304.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1802.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1802.00 ft2 6. Conditioned floor area above grade (ft2) 1802 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(144.0 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.29 72.00 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 250 SHGC: SHGC=0.29 b. U-Factor: Dbl, U=0.32 42.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.29 30.00 ft2 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 1.451 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.275 a. Electric Heat Pump 35.0 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1802.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1802.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.080 Total Proposed Modified Loads: 48.80 PASS Total Baseline Loads: 52.40 I hereby certify that the plans and spe ' icalions covered by Review of the plans and -SIRE ST,g1� this calculation are in compliance with a Florida Energy specifications covered by this O� Code. calculation indicates compliance with the Florida Energy Code. .rr,,,,-., •:= ;;,• `'� `�O PREPARED BY: Before construction is completed emu.. ;s • �.,, . DATE: this building will be inspected for compliance with Section 553.908 esigned, is in compliance I hereby certify that thif4� Florida Statutes. with the Florida Energ �0 WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 8/19/2021 7:30 AM EnergyGaugeoD USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HOMECRETE - ROBINSON 2 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1802 Lot # Owner Name: ROBINSON RES. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMECRETE HOMES Rotate Angle: 90 Street: 5403 DEER RUN DR. Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1802 14416 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BED 4 147 1176 No 1 3 1 No Yes Yes 2 DINING 143 1144 No 0 1 No Yes Yes 3 KITCHEN FOYER 195 1560 No 0 1 No Yes Yes 4 LAUNDRY 45 360 No 0 1 No Yes Yes 5 BATH 2 84 672 No 0 1 No Yes Yes 6 BED 3 120 960 No 1 1 No Yes Yes 7 BED 2 221 1768 No 1 1 No Yes Yes 8 GREAT ROOM 412 3296 No 0 1 No Yes Yes 9 MASTER WIC 84 672 No 0 1 No Yes Yes 10 MASTER BATH 126 1008 No 0 1 No Yes Yes 11 MASTER BED 225 1800 No 2 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 4 30 ft 0 147 ft2 ---_ 0 1 0 2 Slab -On -Grade Edge Insulatio DINING 27 ft 0 143 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio KITCHEN FOYE 7 ft 0 195 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 45 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio BATH 2 20 ft 0 84 ft2 --__ 1 0 0 6 Slab -On -Grade Edge Insulatio BED 3 12 ft 0 120 ft2 _-__ 0 1 0 8/19/2021 7:30 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio BED 2 30 ft 0 221 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio GREAT ROOM 19 ft 0 412 ft2 ---_ 0 1 0 9 Slab -On -Grade Edge Insulatio MASTER WIC 6 ft 0 84 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio MASTER BATH 8.5 ft 0 126 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio MASTER BED 30 ft 0 225 ft2 --_- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1952 ft2 0 ft2 Medium N 0.9 No 0.9 No 20 22.62 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1802 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BED 4 0 Blown 147 ft2 0.1 Wood 2 Under Attic (Unvented) DINING 0 Blown 143 ft2 0.1 Wood 3 Under Attic (Unvented) KITCHEN FOYE 0 Blown 195 ft2 0.1 Wood 4 Under Attic (Unvented) LAUNDRY 0 Blown 45 ft2 0.1 Wood 5 Under Attic (Unvented) BATH 2 0 Blown 84 ft2 0.1 Wood 6 Under Attic (Unvented) BED 3 0 Blown 120 ft2 0.1 Wood 7 Under Attic (Unvented) BED 2 0 Blown 221 ft2 0.1 Wood 8 Under Attic (Unvented) GREAT ROOM 0 Blown 412 ft2 0.1 Wood 9 Under Attic (Unvented) MASTER WIC 0 Blown 84 ft2 0.1 Wood 10 Under Attic (Unvented) MASTER BATH 0 Blown 126 ft2 0.1 Wood 11 Under Attic (Unvented) MASTER BED 0 Blown 225 ft2 0.1 Wood WALLS Adjacent Space CavityR_Valup Width In Height Ft In Area Sheathing Framing Solar R--Valtle Ernrfion AhSnr BelowPt o _ 1 N=>E Exterior Concrete Block - Int Insul BED 4 6.5 12 0 8 0 96.0 ft2 0 0 0.5 0 _ 2 E=>S Exterior Concrete Block - Int Insul BED 4 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 3 S=>W Exterior Concrete Block - Int Insul BED 4 6.5 4 0 8 0 32.0 ft2 0 0 0.5 0 4 N=>E Exterior Concrete Block - Int Insul DINING 6.5 4 0 8 0 32.0 ft2 0 0 0.5 0 5 E=>S Exterior Concrete Block - Int Insul DINING 6.5 11 0 8 0 88.0 ft2 0 0 0.5 0 _ 6 S=>W Exterior Concrete Block - Int Insul BATH 2 6.5 6 0 8 0 48.0 ft2 0 0 0.5 0 _ 7 S=>W Exterior Concrete Block - Int Insul BED 3 6.5 15 0 8 0 120.0 ft2 0 0 0.5 0 8 S=>W Exterior Concrete Block - Int Insul BED 2 6.5 13 0 8 0 104.0 ft2 0 0 0.5 0 8/19/2021 7:30 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2ron IAIDI IT QI IRARRAE2V I-Ucnvl it-r mr-n^.mT WALLS Adjacent Wall Twe Space Cavity Width Height Sheathing Framing Solar Below o• _ 9 W=>N Exterior Concrete Block - Int Insul BED 2 6.5 17 0 8 0 136.0 ft2 0 0 0.5 0 _ 10 W=>N Exterior Concrete Block - Int Ins(DREAT ROO 6.5 19 0 8 0 152.0 ft2 0 0 0.5 0 11 N=>E Exterior Concrete Block - Int InsUASTER WI 6.5 6 0 8 0 48.0 ft2 0 0 0.5 0 _ 12 N=>E Exterior Concrete Block - Int InsMASTER BA 6.5 8 6 8 0 68.0 ft2 0 0 0.5 0 _ 13 N=>E Exterior Concrete Block - Int InsWASTER BE 6.5 16 0 8 0 128.0 ft2 0 0 0.5 0 _ 14 W=>N Exterior Concrete Block - Int InsAAASTER BE 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 -15 N=>E Garage Frame - Wood LAUNDRY 11 38 8 304.0 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated LAUNDRY None .39 3 6 8 20 ft2 2 E=>S Wood DINING None .46 2.8 6.8 19 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 90 degrees). / V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E=>S 2 Metal Double (Tinted) Yes 0.29 0.26 N 15.0 ft2 1 ft 6 in 1 ft 0 in None None 2 E=>S 5 Metal Double (Tinted) Yes 0.29 0.26 N 15.0 ft2 1 ft 6 in 1 ft 0 in None None 3 S=>W 7 Metal Double (Tinted) Yes 0.29 0.29 N 15.0 ft2 1 ft 6 in 1 ft 0 in None None 4 W=>N 9 Metal Double (Tinted) Yes 0.29 0.29 N 15.0 ft2 1 ft 6 in 1 ft 0 in None None 5 W=>N 10 Metal Double (Tinted) Yes 0.32 0.26 N 42.0 ft2 1 ft 4 in 1 ft 0 in None None 6 N=>E 12 Metal Double (Tinted) Yes 0.29 0.29 N 12.0 ft2 1 ft 6 in 1 ft 0 in None None 7 W=>N 14 Metal Double (Tinted) Yes 0.29 0.29 N 30.0 ft2 1 ft 6 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wail Insulation 1 387 ft2 387 ft2 42 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1201.3 65.91 123.74 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singi HSPF:8.5 35 kBtu/hr 1 sys#1 8/19/2021 7:30 AM EnergyGaugee USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2wn IAIDI IT CI IRARAAw r+u=r+vi irT nr�nr m r COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtulhr 1050 cfm 0.76 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / --- Supply ---- V/ -- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft2 Attic 150 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Heating H Jan H Feb Venting Mar Mar ki Apr E i ArEIMayrlJun Ma Jun X Jul f l Jul Au4 rj Aug Se i Sep Oct OctNov Nov ] Dec Xl Dec Jan Feb Mar X Apr ( May Jun [ Jul Aug [ Se [X Oct [X Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 80 80 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BED 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BED 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BED 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC BED 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH BED 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 LIV DIN FOYER Default(8 Ibs/s .ft. ft2 ft 0.3 KITCHEN 8/19/2021 7:30 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. 5403 DEER RUN DR., FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=6.5 1276.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 304.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Roof Deck (Unvented) R=20.0 1802.00 ft2 6. Conditioned floor area (ft2) 1802 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.29 72.00 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 250 b. U-Factor: Dbl, U=0.32 42.00 ft2 SHGC: SHGC=0.26 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.29 30.00 ft2 a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.26 d. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.451 ft. a. Electric Heat Pump 35.0 HSPF:8.50 Area Weighted Average SHGC: 0.275 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): NIA ft2 a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.95 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1802.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home Construction through t in this home before fig based on installed Cdc Builder Signature: plied with the Florida Energy Efficiency Code for Building energy saving features which will be installed (or exceeded) rion t #rwise, a new EPL Display Card will be completed KyAwl/m Address of New Home: � f�� City/PL Zip: Q �y©x114E ST,g18 WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/19/2021 7:30 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project Summary Entire House "�°"'" "` Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421.4117 Fax: 954-420.0064 Web: www.lindstrornair.com Prooect Information For: HOMCRETE • a. ROBINSON Design Information Weather: Winter Design Conditions Outside db 41 OF Inside db 70 OF Design TD 29 OF Heating Summary Structure 20576 Btuh Ducts 3368 Btuh Central vent (72 cfm) 2294 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 26237 Btuh Infiltration Method Construction quality Fireplaces St Lucie Co Intl, FL, US Simplified Average 0 Area ft z(W) Heating Coolin Volume 14408 14408 Air changes/hour Equiv. 0.38 0.20 AVF (cfm) 91 48 Heating Equipment Summary Make CARRIER Trade Model CH16NA036 AHRI ref Efficiency 8.5 HSPF Heating input Heating output 35000 Btuh @ 47°F Temperature rise 27 OF Actual air flow 1200 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Space thermostat Capacity balance point = 0 OF Backup: CARRIER 5 KW Input = 6 kW, Output = 20716 Btuh, 100 AFUE Job: Date: 7-2021 By: LINDSTROM Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Sensible Cooling Equipment Load Sizing Structure 18091 Btuh Ducts 5482 Btuh Central vent (72 cfm) 1218 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 23651 Btuh Latent Cooling Equipment Load Sizing Structure 3056 Btuh Ducts 1474 Btuh Central vent _(72 cfm) 2781 Btuh Outside air Equipment latent load 7311 Btuh Equipment Total Load (Sen+Lat) 30962 Btuh Req. total capacity at 0.78 SHR 2.5 ton Cooling Equipment Summary Make CARRIER Trade Cond CH16NA036 Coil FX4DNF037 AH R I ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 27200 Btuh 7800 Btuh 35000 Btuh 1200 cfm 0.051 cfm/Btuh 0 in H2O 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - wri14ghtsoft^ 2021-Aug-19 07:40:40 »•• Right -Suite® Universal 2019 19.0.12 RSU08398 Page 1 ACCA ...CTS ENERGYIA- MANUAL JIHOMECRETE - ROBINSON.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet CPAPM, Job: Entire House Date: 7-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAS RD, POMPANO BEACH, FL 33069 Phone: 954-421.4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 2 Room name Exposed wall Entire House LIVING RM 3 Room height 195.5 ft 30.0 ft 4 Room dimensions 8.0 ft 8.0 ft heat/cool 5 Room area 1801.0 ft2 12.5 x 12.0 ft 150.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (W) Load number (Btuh/W °F) (Btuh/ftq or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6VL_G13A-6ocs 0.111 n 3.22 1.79 372 360 1159 643 96 96 309 172 1D-h2om 0.870 n 25.23 22.62 12 0 303 271 0 0 0 0 0.111 a 3.22 1.79 278 226 727 404 112 97 312 173 1:13A-6ocs 211 113-h2om 0.870 a 25.23 54.06 30 3 757 1622 15 1 378 811 11 DO 0.390 a 11.31 11.43 22 22 249 251 0 0 0 0 13A-6ocs 0.111 S 3.22 1.79 304 289 930 516 32 32 103 57 1D-h2om 0.870 s 25.23 22.62 15 30 378 339 0 0 0 0 1kJ 13A-6ocs 0.111 w 3.22 1.79 400 329 1059 588 0 0 0 0 1 D-h2om 0.870 w 25.23 54.06 30 3 757 1622 0 0 0 0 lD-h2omd 0.870 w 25.23 22.62 41 82 1034 928 0 0 0 0 P 12B-Obw 0.097 - 281 0.88 312 290 816 256 0 0 0 0 11 DO 0.390 n 11.31 11.43 22 22 249 251 0 0 0 0 C 1613-19ad 0.049 a 1.42 2.59 1801 1801 2559 4660 150 150 213 388 F 22A-tpm 1.180 a 34.22 0.00 1801 196 6690 0 150 30 1027 0 6 c) AED excursion 1146 1 1-67 Envelope loss/gain 17668 13498 2342 1534 12 a) Infiltration 2908 813 515 144 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 6 1380 2 460 Appliances/other 2400 0 Subtotal (lines 6 to 13) 20576 18091 2858 2138 Less external load 0 0 0 0 ]15 Less transfer 0 0 0 0 Redistribution 0 0 0 0 Subtotal 20576 18091 2858 2138 Duct loads 16% 300/0 3368 5482 16% 30% 467 646 Total room load 23943 23573 3325 2784 Air required (cfm) 1200 1200 1 167 142 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - wrfightsoft� 2021-Aug-19 07:40:40 - Right -Suite® Universal 2019 19.0.12 RSU08398 Page 1 ...CTS ENERGY\A- MANUAL J\HOMECRETE -ROB[ NSON. rup Calc = MJ8 Front Door faces: N o Right-JO Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax 954-420-0064 Web: www.lindstromair.com Job: Date: 7-2021 By: LINDSTROM 1 Room name DINING KITCHEN FOYER 2 Exposed wall V.0 ft 7.0 ft 3 Room height 8.0 ft heat/ccol 8.0 ft heat/cool 4 Room dimensions 11.0 x 13.0 ft 13.0 x 15.0 ft 5 Room area 143.0 ft' 195.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ft� Load number (BtutVW °F) (Btuh/ft� or perimeter (ft) (St uh} or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross NIP/S Heat Cool 6 Ulf 13A-6ocs 0.111 n 3.22 1.79 32 32 103 57 0 0 0 0 l--G 1 D-h2om 0.870 n 25.23 22.62 0 0 0 0 0 0 0 0 13A-6ocs 0.111 a 3.22 1.79 88 51 164 91 0 0 0 0 J:j1 D-h2om 0.870 a 25.23 54.06 15 1 378 Bill 0 0 0 11 11 DO 0.390 a 11.31 11.43 22 22 249 251 0 0 0 0 13A-6ocs 0.111 s 3.22 1.79 0 0 0 0 0 0 0 0 10-h2om 0.870 s 25.23 22.62 0 0 0 0 0 0 0 0 13A-60cs 0.111 w 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 26.23 54.06 0 0 0 0 0 0 0 0 1 D-h2omtl 0.870 w 25.23 22.62 0 0 0 0 0 0 0 0 P L-D 12B-Obw 0.097 - 2.81 0.88 96 96 270 85 56 56 158 49 11 DO 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0 C 16B-19ad 0.049 a 1.42 2.59 143 143 203 370 195 195 277 505 F 22A-tpm 1.180 a 34.22 0.00 143 27 924 0 195 7 240 0 6 c) AED excursion -41 -165 Envelope loss/gain 2292 1624 674 389 12 a) Infiltration 258 72 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 2400 Subtotal (lines 6 to 13) 2549 1696 674 2789 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2549 1696 674 2789 1161 Duct loads 16% 30% 416 513 16% 30% 110 843 Total room load 2966 2209 784 3632 Air required (cfm) 1491 112 39 185 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlg2021-Aug-19 07:40:40 Right -Suite® Universal 2019 19.0.12 RSU08398 Page 2 '��p` ...CTS ENERGY�A- MANUAL JIHOMECRETE - ROBINSON.rup Calc= MJ8 Front Door faces: N Aft Right-J® Worksheet°b w Entire House Date: 7-2021 -_ Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAE RD, POMPANO BEACH, FL 33069 Phone954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 2 Room name Exposed vvall LAUNDRY BATH 2 3 Room height 6.0 ft 8.0 ft heat/cool 20.0 ft 8.0 ft healdcool 4 Room dimensions 6.0 x 7.5 ft 14.0 x 6.0 ft 5 Room area 45.0 ft' 84.0 ft' Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btutvftz-°F) (Btuwft�) or perimeter (ft) (Btuh) cr perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 V',J 13A-6ocs 0.111 n 3.22 1.79 0 0 0 0 0 0 0 0 G 1D-h2om 0.870 n 25.23 22.62 0 0 0 0 0 0 0 0 U 13A-6ocs 0.111 e 3.22 1.79 0 0 0 0 0 0 0 0 1D-h2om 0.870 e 25.23 54.06 0 0 0 0 0 0 0 0 1 1 11 DO 0.390 e 11.31 11.43 0 0 0 0 0 0 0 0 1qJ 13A-60cs 0,111 s 3.22 1.79 0 0 0 0 48 48 155 86 L-- G ID-h2om 0.870 s 25.23 22.62 0 0 0 0 0 0 0 0 13A-flocs 0.111 w 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 25.23 54.06 0 0 0 0 0 0 0 0 1D-h2omd 0.870 w 25.23 22.62 0 0 0 0 0 0 0 0 PI - 12B-Obw 0.097 - 2.81 0.88 48 26 73 23 112 112 315 99 L-U 11 DO 0,390 n 11.31 11.43 22 22 249 251 0 0 0 0 C 16B-19ad 0.049 a 1.42 2.59 45 45 64 116 84 84 119 217 F 22A-tpm 1.180 e 34.22 0.00 45 6 205 0 84 20 684 0 6 c) AED excursion 22 .24 Envelope loss/gain 591 369 1273 378 12 a) Infiltration 0 0 103 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 591 369 1376 407 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 591 369 1376 407 15 Duct loads 16% 30% 97 112 16% 30% 225 123 Total room load 688 480 1601 530 Air required (cfm) 34 24 80 27 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed - : wrigFttsoi't- 2021-Aug-19 07:40:40 ...^ -• Right -Suite@ Universal 2019 19.0,12 RSU08398 Page 3 p` ...CTS ENERGYIA- MANUAL J\HOMECRETE - ROBINSON.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: Entire House Date: 7-2021 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromaircom 1 Room name BED 3 BED 2 2 3 Exposed wall Room height 12.0 ft 30.0 ft 4 Room dimensions 8.0 ft heat/cool 8.0 ft heat/cool 5 Room area 10.0 x 12.0 ft 17.0 x 13.0 ft 120.0 ft' 221.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/ft2 °F) (Btuhlft� or permeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-rocs 0.111 n 3.22 1.79 0 0 0 0 0 0 0 0 �-G 1D-h2om 0.870 n 25.23 22.62 0 0 0 0 0 0 0 0 13A-6ocs 0.111 e 3,22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0,870 e 2523 54.06 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 11,31 11.43 0 0 0 0 0 0 0 0 13A-6ocs 0.111 s 3.22 1.79 120 105 338 188 104 104 335 186 1D-h2om 0.870 s 25.23 22.62 15 15 378 339 0 0 0 0 13A-60cs 0.111 w 3.22 1.79 0 0 0 0 136 121 389 216 D-h2om 0.870 w 25.23 54.06 0 0 0 0 15 1 378 611 1D-h2omd 0.870 w 25.23 22.62 0 0 0 0 0 0 0 0 P. L-D 12B-Obw 0.097 - 2.81 0.88 0 0 0 0 0 0 0 0 11DO 0,390 n 11.31 11.43 0 0 0 0 0 0 0 0 C 158-19ad 0.049 e 1.42 2.59 120 120 171 310 221 221 314 572 F 22A-tpm 1.180 e 34.22 0.00 120 12 411 0 221 30 1027 0 6 c) AED excursion -64 236 Envelope loss/gain 1298 774 2443 2021 12 a) Infiltration 258 72 515 144 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1555 1076 2959 2395 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1555 1076 2959 2395 15 Ductloads 16% 30`,'/0 254 325 16% 30% 483 724 Total room load 1809 1401 3442 3119 Air required (cfm) 91 71 173 159 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed +� wrigtitso... 2021-Aug-19 07:40:40 Right -Suite® Universal 2019 19.0.12 RSU08398 Page 4 '`� k ...CTS ENERGY\A- MANUAL J\HOMECRETE - ROBINSON.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: Entire Mouse Date: 7-2021 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0094 w.h -, r 1 2 Room name Exposed wall GREAT ROOM MASTER WIC 3 Room height % ft 6.0 ft 4 Room dimensions 8.0 ft heat/cool a.0 ft heat/cool 5 Room area 24.0 x 17.0 ft 8.0 x 6.0 ft 408.0 ft2 48.0 ft' ry Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuhlft2-°F) (BtuNft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 LL 13A-6ocs 0.111 n 3.22 1.79 0 0 0 0 48 48 155 86 -G 1D-h2om 0.870 n 25.23 22.62 0 0 0 0 0 0 0 0 13A-6ocs 0.111 e 3.22 1.79 78 78 251 139 0 0 0 0 1 D-h2om 0 670 e 25.23 54.06 0 0 0 0 0 0 0 0 1 1 11 DO 0390 e 11.31 11.43 0 0 0 0 0 0 0 0 T--G 13A-6ocs 0.111 s 3.22 1.79 0 0 0 0 0 0 0 1 D-h2om 0,870 s 25.23 22.62 0 0 0 0 0 0 0 0 0 U(� 13A-6o s 0.111 w 3.22 1.79 152 'I'll 357 198 0 0 0 0 --CGS fL-- 1 D-h2om 0.870 w 25.23 54.06 0 0 0 0 0 0 0 0 P 1 D-h2omd 126-Obw 0.870 0.097 w - 25.23 2.81 22.62 41 41 1034 928 0 0 0 0 i--D 11 DO 0.390 n 11.31 0.88 11.43 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C F 16B-19ad 0.049 e 1.42 2.59 408 408 580 1056 48 48 68 0 124 22A-tpm 1.180 e 34.22 0.00 408 19 650 0 48 6 205 0 6 c) AED excursion 1130 -13 Envelope loss/gain 2873 3451 428 197 12 a) Infiltration 494 138 103 29 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3367 3589 531 225 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 3367 3589 531 225 16% 30°% 550 1085 '16% 30% 87 68 Total room load Air required (cfm) 3917 4674 618 294 196 238 31 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed +�- wrightsoft* �^�A • • •• Right-Suitem Universal 2019 19.0.12 RSU08398 2021-Aug-19 07:40:40 Page 5 ..CTS ENERGY\A- MANUAL J\HOMECRETE - ROBINSON.rup Calc = MJ8 Front Door faces: N ON Job: Right-J® Worksheet Entire House Date: 7-2021 CZIAI:jw�By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421.4117 Fax: 954-420-0064 Web: www.lindstromaircom 1 2 Room name Exposed wall MASTER BATH MASTER BED 3 Room height 8.5 ft 30.0 ft 4 Room dimensions 8.0 ft heat/cool 8.0 ft heat/cool 5 Room area 9.0 x 14.0 ft 15.0 x 15.0 ft 126.0 ftz 225.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuhtft2--F) (BtutVft') or perimeter (ft) (Btuh) or perimeter (ft) (8tuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 �j✓ --G 13A-6ocs 1 D-h2om 0.111 n 3.22 1.79 68 56 180 100 128 128 412 229 0.870 0.111 n a 25.23 3.22 22.62 1.79 12 0 0 0 303 271 0 0 0 0 tJ13A-6ocs O 1 D-h2om 0,870 a 25.23 54.06 0 0 0 0 0 0 0 0 0 0 0 0 0 11 11 DO 0.390 a 11.31 11.43 0 0 0 0 0 0 0 0 0 13A-6ms 0.111 s 3.22 1.79 0 0 0 0 0 0 0 0 1 D-h2om 0.670 s 25.23 22.62 0 0 0 0 0 0 0 0 13A-600s 0.111 w 3,22 1.79 0 0 0 0 112 97 312 173 1 D-h2om 0.870 w 25.23 54.06 0 0 0 0 15 1 378 811 1D-h2omd 0.870 w 25.23 22.62 0 0 0 0 0 0 0 0 P L-D 126-Obw 0.097 - 2,81 0.88 0 0 0 0 0 0 0 0 1166 0.390 n 11.31 11.43 0 0 0 0 0 0 0 0 Cr F 168-19ad 0.049 a 1.42 2.59 125 126 179 326 225 225 320 582 22A-tpm 1.180 a 34.22 0.00 126 9 291 0 225 30 1027 0 6 c) AED excursion -41 223 Envelope loss/gain 953 656 2449 2018 12 a) Infiltration 146 41 515 144 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 2 4W Appliances/other 0 0 Subtotal (lines 6 to 13) 1099 697 2965 2672 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 15 Subtotal Duct loads 1099 697 2965 2622 160/0 30% 180 211 161/0 300/0 484 793 Total room load 1279 908 3449 3414 Air required (cfm) 64 461 173 174 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed w-rlgF�tsoft- �- Right-SuiteC9 Universal 2019 19.0.12 RSU08396 2021-Aug-19 07:40:40Page 6 '���` ...CTS ENERGY\A- MANUAL J\HOMECRETE - ROSINSON.rup Calc = MJB Front Door faces: N Right-JO Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD. POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromaircom Job: Date: 7-2021 By: LINDSTROM 1 Room name WIC INT 2 Exposed wall 0 f1 3 Room height 8.0 ft heat/cod 4 Room dimensions 6.0 x 6.0 ft 5 Room area 36.0 ft2 Ty Construction U-value Or HTM Area (fe) Load Area Load number (Btuhlft? `F) (BtutVftl) or perimeter (ft) (Brun) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Coc! 6 4 13A-6ocs 0.111 n 3.22 1.79 0 0 0 0 1 D-h2om 0.870 n 25.23 22.62 0 0 0 0 0.111 e 3.22 1.79 0 0 0 0 1 D-h2om 0 870 e 25.23 5406 0 0 0 0 11T:J13A-6ocs D11 DO 0.390 e 11.31 11.43 0 0 0 0 1QJ 13A-6ocs 0.111 s 3.22 1.79 0 0 0 0 -(; 1 D-h2om 0 870 s 25.23 22.62 0 0 0 0 UJ 13A-6ocs 0.111 w 3.22 1.79 0 0 0 0 1 D-h2om 0.870 w 25.23 54.06 0 0 0 0 ID-h2omd 0.870 w 25.23 22.62 0 0 0 0 P 12"bw 0 097 - 2.81 0.88 0 0 0 0 (--D 11 DO 0,390 n 11,31 11.43 0 0 0 0 C 16B-19ad 0.049 a 1.42 2.59 36 36 51 93 F 22A-tpm 1.180 e 34.22 0.00 36 0 0 0 6 c) AED excursion -5 Envelope loss/gain 51 88 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 1ntemal gains: Occupants Q 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 51 88 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 51 88 15 Duct loads 28% 45% 14 40 Total room load 66 148 Air required (cfm) 3 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f}+ wrigFstsoft 2021-Aug-19 07:40:40 Right-Suiteb Universal 2019 19.0 12 RSU08398 Page 7 ...CTS ENERGY\A- MANUAL JIHOMECRETE - ROBINSON.rup Cale = MJ8 Front Door faces: N