Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY CALCS & MANUAL J - 58 MEDITERRANEAN NORTH(1)
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Typet1432.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 W 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 c. NIA 4. Number of Bedrooms 3 R= ftz d. NIA R= ft2 5. 1s this a worst case? Yes 11. Ceiling Types (1783.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ftz) 1753 b. Knee Wall (Vented) R=19.0 30.00 ftz Conditioned floor area below grade (ftz) 0 c. NIA R= ftz 7. Windows(151.4 sgft.) Description Area 12. Ducts R f' a. U-Factor: Sgi, U=1.02 111.36 ftz a. Sup: Attic, Rot: Attic, AH: Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.2$5 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor.(AVG) NIA ftz SHGC(AVG): NIA 15. Hot water systems 9_ Floor Types (1753.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. NIA R= ftz None c. NIA R= ft2 16. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total A Baseline Loads: 50.69 hereby certify that the plans and specifications covered by this calculation are in compliance Florida Review of the plans and with the Energy specifications covered by this Code, calculation indicates compliance,,,�'� with the Florida Energy Code. PREPARED BY: ti �$ DATE: 1-12-2021 Before construction is completed rsa -• '�° this building will be inspected for compliance with Section 553.908 A I hereby certify that this building, as designed compliance with the Florida Energy Code~'per, * Florida Statutes. WF OWNERIA BUILDING OFFICIAL: DATE: 1 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires envelope leakage test report with envelope leakage no greater an than 5.00 ACH50 (R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FSC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPART PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE JDesign Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range _ FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 It 0 63 ft' 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 It 0 56 IF ___ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 It 0 36 ft' ___ 0 1 0 1/12/2021 1:16 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 __ 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 __ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 �_ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 0 1 0 _ 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ___ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 __ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor, Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / `/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood _ 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below e 1 NE=>SW Exterior Concrete Block - Int InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 2 SW=>NE Exterior Concrete Block- Int InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 _ 3 NW=>SE Exterior Concrete Block - Int InsWASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 4 NE=>SW Exterior Concrete Block - Int Ins011ASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 -5 NE=>SW Exterior Concrete Block- Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.3 0 7 SW=>NE Exterior Concrete Block- Int InsMINING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.3 0 8 NW=>SE Exterior Concrete Block - Int Ins(DINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 9 SW=>NE Exterior Concrete Block- Int Insu1KITCHEN 4.1 11 0 8 0 88.0 ft- 0 0 0.3 0 _ 10 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 11 SE=>NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 12 SW=>NE Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 NE=>SW Exterior Concrete Block- Int Ins8EDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 _14 SW=>NE Exterior Concrete Block- Int Ins8EDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N=>S Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft- 0.23 0.3 0 DOORS # Omt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. Wall Overhang v # OrM ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft- 1 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft2 It 0 in 1 ft 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 It 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft' 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKI IST RFPART HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing] HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None {(_ DUCTS / — Supply — -- Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft- Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb VentnOct g Jan Feb Ma Mar �A Apr € (XI Jun [)Jul jX� [ j Aug jX� [ ] Sep ] Nov 11 Oct Dec [ ]X May Jun I 1 Jul [ ]Aug I 1 Sep txJ Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heabng(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft= ft 0.3 WIC Default(8 Ibs/sq.ft. ft= ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(81bs/sq.ft. ft= ft 0.3 LAUDRY Default(81bs/sq.ft. ft= It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft= ft 0.3 DINING/GREAT R Default(81bs/sq.ft. ft= ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRe52020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 I-ORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Defauft(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(B lbs/sq.ft. ft' it 0.3 FOYER Default 8 lbs/sci.ft. ft' It 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT h II Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. x Owner: Jurisdiction: w Design Location: FL, Fort Pierce = V COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped /soffit y pp ceilin g the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous ali nment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulaton, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be out neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nining iii2d wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a In addition in t nki I , spec i on o f og via II s s a be f ICC-400. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC An Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft' b. Frame- Wood, Adjacent R=11.0 208.00 ft- 3. Number of units, if multiple family 1 c. N/A R= W 4. Number of Bedrooms 3 d. N/A R= ft° 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft- 6. Conditioned floor area (ft') 1753 b. Knee Wall (Vented) R=19.0 30.00 ft' 7. Windows" Description Area c. N/A R= ft' a. Sgl, U= 229 111.36 ft' 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 SHGC: SHGC:: SHGC=0. b. U-Factor: Sgl, U=1.11 40.00 ft' SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A TP SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft, a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.97 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft- Credits (Performance method) None b. N/A R= ft' c. N/A R= fF I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: (\City/FL Zip:�S� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project Summary o: wrighltsof#° Entire House BY. QUICK CALCS, INC. 317 ST. LUCIE LN.,Fr. PIERCE, FL 34946 Prune: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@40LCOM Promect Information For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 of Outside db 90 of Inside db 70 °F Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grflb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Ducts 6191 Btuh Duds 9337 Blurl Central vent (0 chn) 0 Btuh Central vent (0 cfm) 0 Btuh (gone) e) 0 Btuh Blower 0 Btuh Piping 0 Bluh Equipment load 27734 Btuh Use manufacturer's data n Rate/sw ng multiplier Equipment 0.95 Infiltration sensible load 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Duds 2546 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Coolingg (none) (ft=) 1753 1753 Equipment latent load 5041 Btuh Volume(fP) 16478 16478 Airchangesihour 0.38 0.20 Equipment Total Load (Sen+Lat) 29511 Btuh Equiv.AVF(dm) 104 55 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A'030 Cond 25HBC536XO30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHI ref 7914585 Ef6dency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensiblecooling 24360 Btuh Heating output 34600 Btuh @47-F Latent000ling 10440 Btuh Temperaturedse 27 of Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 dm Airflowfador 0.042 dm/Btuh Airflowfador 0.045 cim/BWh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point = 36 of Backup: Input=7kW, Output=23009Btuh,100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed wFrg"TiS ft- 2021-Jan1213:18:18 RigI1SLile@UriwmI201919.021 RSU08101 ...Dor6\WngktwRHUARWY NE-THEWINDSORnp Calc=MJB FrortDoorfacesN Paget v wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Plum: 772-466-6799 Fax 772-466-6796 Email OUCKCALCSa@AOL.COM 1 Room name Erdm Hone BEDROOM 2 Etryosed wall 207.6 ft 41A ft 3 Room height 9.4 ft d 9.4 ft heat/==] 4 Room dimensons 14.0 x 200 ft 5 Rwmarea 1753.0 ft 280D R' Ty Combudon U-value Or HTM Area Load A� (fll� Loadnumber (BIuhW--q (Btuw) or penm�r (ft) (BhWh) or penmeler (ft) (eWh) Heat Cool Gross NIPS Heat Cool Gros NIPS Heat Cool 6 13A4= 0.143 In 4.00 2.55 649 598 2386 1517 66 66 263 167 1Ac7om 1270 n 35.56 34.77 15 0 533 Sm 0 0 0 0 4A5-20m 0.770 n 2156 19.31 38 0 815 730 0 0 0 0 w 13AA= 0.143 ne 4.00 2.55 27 27 106 68 0 0 0 0 17 13AA= 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 tAclom 1270 a 3556 87.06 20 1 711 1741 0 0 0 0 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 - 0 w 13A-4= 0.143 ce 400 255 27 27 106 68 0 0 0 0 w 13A-0ar 0.143 s 4.00 2.55 536 530 2121 1349 188 188 753 479 L—G to -clan 1270 s 3556 34.77 6 6 213 209 0 0 0 0 13A4= 0.143 w 400 255 320 255 1022 649 132 108 432 275 1Aclom 1270 w 35M 54.53 12 1 415 636 12 1 415 636 1Aclom 1270 w 35.56 54.53 12 1 427 654 12 1 427 654 4A5-2om 0.770 w 2156 45.63 41 2 880 18K 0 0 0 0 P 12C-Ow 0.091 255 128 254 254 647 326 0 0 0 0 C 16A30md OA32 - 0.90 2.32 1753 1753 1571 4067 280 280 251 650 IF22Atpl 0.989 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 c)AEDeuursiw 397 488 Ewelope los/gain 18331 15295 3676 3349 12 a) Infiltra4on 3211 9M 729 20 b) Roomventilaffw 0 0 0 0 13 htemal gains O—pams@ 230 1 230 0 Appliances/other 0 0 0 Subtotal(lines6hr13) 21542 16420 4405 3554 LeseNemalload 0 0 0 0 Lestansfer 0 0 0 0 Redis4ibutm 0 0 0 0 14 15 Sub41tal Ductloads 21542 16420 4405 3554 29% 57% 6191 9337 29% 57% 1265 2021 Total room load AirreQuired(cfm) 27734 26757 56711 5575 1160 1160 2371 251 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed Rigk3uteSUriversa1201919.021 RSU08101 2021-J2n12 t3:18:78 ...DoomarlslWngh�tWAC\WVNNE-THEWINDSORnp C-Ic=MI8 Fror Dooffaces.N Paget -rF wrightsoft, Right JO Worksheet Date: Entire House QUICK CALCS, INC. BY 317 ST. LUCIE LN.,FF. PIERCE, FL 34946 PWre: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@F.OL.COM 1 Roan rlame WIC MASTER BATH 2 Erposedwall 0 it 9.0 ft 3 Roan height 9.4 ft hedtDO] 9A ft heaVmol 4 Raom dime . 7.0 x 9D ft 7.0 x 9.0 ft 5 Room area 63D fF 63.0 iP Ty Construldion U-%WW Or HTM Area (IF) Load Am number I (BUTAFL*Fj (BWftflt� or Perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Glow WPS Heat Cool Grote NrPS Heat Cool 6 wl - 13A-4= 0.143 n 4A0 2.55 0- 0 0 - 0 0 0 0 0. IL---GG 1Actan 12M n 3556 34.77 0 0 0 0 0- 0 0 0 4A5-2= 0.770 n 21M 1931 0 0 0 0 0 0 0 0 W 13A4as 0.143 re 4DO 2S5 0 0 0 0 0 0 0 0 11 Y 13A4oc; 0.143 a 4.00 2M 0 0 0 0 0 0 0 0 �G I—D 1Actom 1270 e - 3556 97.06 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 1131 0 0 0 0- 0 0- 0 0 W 13A4= 0.143 m 4D0 255 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 85 85 339 - 215 f—G IAclam 1270 s 3556 34.77 0 0 0 0 0 0 0- -. 0 13A4as 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 w 35.66 5453 0 0 0 0 0 0 .0 0 IAclom 1270 w 35M 54M 0 0 0 0 0 0 0 0 4A5-2an 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P- 12c-Ow - OD91 - - 2.55 128 - O 0 0 0 0 0 0 0 C 16A30md OD32 - Ox 232 63 63 56 146 63 63 56 146 F 22A-tpl 0.989 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AEDelauson -10 -28 Envelope lossk, n 56 136 644 334 12 a) Infiltration 0 0 160 45 b) Roomvenilation 0 0 0 0 13 Mane gains Omrpants@ 230 0 0 0 0 Appliancesfolher 0 0 Sub1i3W(l1rles6to13) 56 136 804 379 Lesse)demalload 0 0 0 0 LmVansfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 56 136 804 379 15 Durtloads 29% 57% 16 77 290/0 57% 231 216 Total mom load 73 214 1 1036 595 Air required(cfm) 3 10 43 27 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -*- wri9hisoT[^ 2021 Jarv1213:18:18 .4 A RIgHSute4�tlri� l 201919.021 RSLA08101 P 2 _CaarnertslWdgt�oftHVAMWYNNE-THEWIND.SORnp Calc=MJB FrortWorface N � wrightsoft- Righttil® Worksheet Jab: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUGE LN, Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Emil: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E1poeedwall Room height Room dimensions Roomarea MBATH 8.0 It 9.4 ft heabbool 7.0 x 8.0 It 56.0 fF KfrCHEN 8.0 It 9.4 It heatl000l 1.0 x 172.0 ft 172.0 T Ty I Construction number U-wlue (BWh4F--F) Or HTM (BWhMt� Area or perimeter (ft) Load (BWh) oorperim� (ft) (BWh) Heat Cool Grass NIPS Heat Cool Gross NIPS Heat Cool 6 11 y/ I�-CC W `�' �G �D 13A-4ocs 1Aciom 4A5-2om 13A-4ocs 13A4= 1Aclorn 11 D0 13A4ocs 13A-4= 1Aclom 13A-4= 1Aelom IA-clom 0.143 1270 0.770 0.143 0.143 1270 0.390 0.143 0.143 1270 0.143 1270 1270 n n n ne a a a se s s w w w 4.00 3556 21.56 4.00 4.00 3556 10.92 4.00 4.00 3556 4.00 3556 35.56 2S5 34.77 19.31 2.55 2S5 87.06 11.31 2.55 2.55 34.77 2.55 54.53 54.53 0 0 0 0 0 0 0 0 75 6 0 0 0 0 0 0 0 0 0 0 0 69 6 0 0 0 0 0 0 0 0 0 0 0 277 213 0 0 0 0 0 0 0 0 0 0 0 176 209 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 w W I-G P c F 4A5-2om 12C-O v 16A.30md 22A-tpl 0.770 0.091 0.032 0.989 w - - 2156 2.55 0.90 27,69 45.63 128 2.32 0.00 0 0 56 56 0 0 56 8 0 0 50 222 0 0 130 0 0 75 172 172 0 75 172 8 0 192 154 222 0 96 399 0 6 c)AEDe mon g8 -34 Emalopeloss/gain 762 477 567 462 12 a) Infiltration b) Roomuznfilabon 142 0 40 0 0 0 0 0 13 Internal gains Oaupants@ 230 0 0 0 0 Applianordother 0 0 Subtotal(lines6to13) 904 517 567 462 14 15 Les edemal load Lestransfer Redistribution Subtotal Dud loads 29% 57% 0 0 0 904 260 0 0 0 517 294 29% 57% 0 0 0 567 163 0 0 0 462 263 Total room bad Airrequired(Qm) 1164 49 811 37 730 311 725 33 Calculations approved bvACCAto meet all requirements of Manual J ft Ed. '' Rigrt-SULOL;riv M1201919.021 RSU08101 2021-Jan1213:18:18 ' ~ ...Doo rtslWngFLsoft HVAC1WYNNE-TFEWINDSORny Calc=MU8 FrontDoorfaces: N Pa9 e3 wrightsoft° Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.. LUCIE LN., FT. PIERCE, FL 34946 Piore: 772-466-6799 Fax T 2466-6796 Email: OUICKCALCS AOL.COM 1 Room name BATH BEDROOM2 2 Eposedwall 5.0 ft 42.6 ft 3 Room height 9.4 R heatrcool 9.4 It heaNcool 4 Room dimensono 9.0 x 5.0 ft 1.0 x 204D R 5 Room area 45.0 1F 204.0 ft Ty Construction U-value Or HTM Area (ft� Load number EtihhF-°F) (BNhAF) or perimeter (ft) (BWh) or perimeter (ft) (Bluh) Heat Cool Gross N/PrS Heat Cool Gross WPS Heat Cool 6 ell 13A-4o s 0.143 n 4.00 2.55 47 47 188 120 132 132 527 335 1Aclom 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 ��lG' 4A5-20m 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 13A-4ots 0.143 ne 4.00 2S5 0 0 0 0 27 27 106 68 17 13A4ocs 0.743 a 4.00 2.55 0 0 0 0 85 65 269 164 L:j1Actan 1270 a 3556 87.06 0 0 0 0 20 1 711 1741 11DO 0.390 a 10.92 1131 0 0 0 0 0 0 0 0 w 13A4= 0.143 se 4.00 255 0 0 0 0 27 27 106 68 13A-4= 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 1Ac1w 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1= 1270 w 3556 5453 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5.2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-0src 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 45 45 40 104 204 204 183 473 F 22A-tpl 0.989 - 27.69 0.00 45 5 138 0 204 43 1179 - 0 6 c)AMe=rsim -17 .99 Envelope loa(gain 367 207 3599 3085 12 a) Infiltration 89 25 758 214 b) Room verrtilation 0 0 0 0 13 Interval gains: O=pants@ 230 0 0 0 0 Applianoesbther 0 0 Subtotal(Iines6to 13) 456 232 4357 3299 Leasexfemal load 0 0 0 0 Lesstrarsrer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 456 232 4573299 15 DuCloads 29% 57% 131 132 29% 67% 12 187652 1876 Total room load 587 364 5609 5175 Air required(cim) 25 16 235 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed 2021JarF1213:18:18 RigkTHE WINDSOse1201919.021 RSU081 o Page4 -.DoamerlslWrigHmRHVAC\WYNNE-THE WINDSORnp Calc=Nu6 Frort Doorfa�sN wrightsoft, Right-J® Worksheet JC& Entire House Date: QUICK CALCS, INC. BY,. 317 ST. LUCIE LN., Fr. PIERCE, FL 34M Rom:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS®WLCOM 1 Room name ENTRY LAUNDRY 2 Elrposedwall 18.0 It 13.0 ft 3 Room height 9A It heaUmol 94 ft heaV=l 4 Room dimensons to x 92.0 ft 7A x 6.0 ft 5 Room area 920 fF 420 W Ty Construction U-%slue Or HTM Area Load A� number fthffi Fn (Btuh4� or penm� (it) (uh) a wa penmeeffi M (Btuh) Heat Cool Gross NIPM Heat Cool Gros NPIS Heat Cool 6 Vy 13A4= C143 n 4.00 255 0 0 0 0 0 0 0 0 H—G L--G 1AcIom 1270 n 35.56 34.77 0 0- 0 0 0 0 0 0 4As2om 0.770 n 2156 1931 0 0 0 0 0 0 0- o w 13A4= 0.143 re 4A0 2.55 0 0 0 0 0 0 0 0 11 ly - 13A-4ocs 0.143 a 4.00 255 56 35 142 90 0 0 0 0 �—DG 1Actom 1270 a 35M 97M 0 0 0 0 0 0 0 0 11DO 0.390 a 1092 1131 21 21 229 238 0 0 0 0 w 13A4= 0.143 se 4.00 255 0 0 0 0 0 0 0 0 1344= 0.143 s 4DO 255 0 0 0 0 56 56 226 144 1Adw 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4as 0.143 w 400 255 0 0 0 0 0 0 0 0 1Ac1am 1270 w 3556 5453 0 0 0 0 0 0 0 0 tActan 1270 w 3556 5453 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P - 12C-Ow OA91 255 128 113 113 287 145 66 66 168: 84 C 16A Vmd 0932 - 0.90 232 92 92 82 213 42 42 38 97 F 22A-V 098 - 2759 0.00 92 18 - 498 0 42 13 360 0 6 c)AEDelcurson -49 -24 Envelope loss'gain 1239 637 791 301 12 a) Infilhalion 107 30 107 30 b) Room%endatlon 0 0 0 0 13 Inlemalgai. Oaupan5@ 230 0 0 0 0 Applianoestter 0 0 SubtotW(lines6b13) 1346 667 898 331 Leser.&mal load 0 0 0 0 Lest ansfer 0 0 0 0 Redistribution 0 0 0 0 14 SubMl 1346 667 898 3 H 15 Ductloads 29% 57% 387 379 --Y/.l 5M.1 258 1 188 Totd room load 1733 1047 1156 520 Air required (dm) 72 47 48 23 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed ¢ - wrlf9hs+olt' 2021-Jan-1213:16:18 RigF-T u WIUriver591 p Calc.081 RSU08101 �k_Doamer�iWn9Fb1/[HVAQWYNNE-'Rff=WINDSORnp CaIc=MI6 Frart Doorf�s N Page5 wrightsoft° Right-M Worksheet Jon: Entire House Date: By. QUICK CALCS, INC. 317 ST. LUCIE LN.,Fr. PIERCE, FL 34946 Ph": 772-066i6799 Fax 772-466-6796 Email: QU1CKCALCS@AOL.00M 1 Room name GREATA MING Room? 2 EVosedwall 50D ft 13,0 It 3 Room height 9.4 ft heatbool 9.4 It heatkool 4 Room rLmereons 1.0 x 557D ft 13D x 13D It 5 Room area 567.0 IF 169D IF Ty Consoucgon U-Value Or HTM Ala (fF) Load Area (112) Load rwmber (Bld'AF-°F) (BWM� or pennnehx (m (BWh) or perimeter (ft) (BWh) Heat Cool Grose NAPS Heat Cool Gros NIPS Heat Cool 6 lM - 13A4o s 0.143 n 4.W 255 262 244 978 622 122 107 429 273 1Ac1om 1270 n 3556 34.77 0 0 - 0 0 15 0 533 522 tI--GG 4A5-2om 0.770 n 21M 1931 38 0 815 730 0 0 0 0 w 13A-4= 0.143 m 4D0 255 0 0 0 0 0 0 0 0 11 tq/ 134-0as 0.143 a 4.00 255 0 0 0 0 0 0 0 0 1Aolom 1270 a 35M 87M 0 0 0 0 0 0 0 0 t�DG 11DO 0.390- a 1092 11.31 - 0 0 0 0 0 - 0 0-- 0 w 1344= 0.143 w 4D0 255 0 0 0 0 0 0 0 0 w 13A4= 0.143 s 4.00 255 0 0 0 0 0 0 0 0 LG 1Aciom 1270 a 3556 34.77 0 0 0 0 0 - 0 0 - 0 13A4= 1143 w 4DO 255 188 147 589 375 0 0 0 0 IA-dw 1270 w 3556 5453 0 0 0 0 0 0 0 0 1Ac1om 12M w 3556 54M 0 0 0 0 0 0 0 0 4A5-20m (I770 w 21M 45.63 41 2 880 18M 0 0 0 0 P 12C-0sv - OD91 255 128 0 0 0 0 0 0 0 0 c 16430md 0D32 - 090 2.32 597 597 508 1315 169 169 151 392 F 22A-tpt 02M - 27.69 0.00 567 - 50 1385 0 169 13 360 - 0 6 c)AED tt rsion 307 -100 Fsvelope loss/gain 5154 5210 14741 1086 12 a) htfiitration 889 251 231 65 b) Rcomeenfilation 0 0 0 0 13 h mel gains: Oovpants@ 230 0 0 1 230 Appliancesb her 0 0 Subbml(lir,aa6b13) 6043 5461 1705 1381 Lew external load 0 0 0 0 Lesstransfer 0 0 0 0 RedLCbLrdm 0 0 0 0 14 SubNfal 6043 5461 1705 1381 15 Durtloads 291% 57% 1737 3105 295/6 57% 490 785 Total roorn load 7780 8566 2195 2167 Air required(rSm) 3251 386 92 98 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed ,C -�-w�ft9ti 2021-JaM21 Page6 ' MgHSLiLO@Li rsat201919.021RS1108101 Page -.Do rtAWd9NsoftHVAMWVNNE-TI-GWINDSORnp Caic=MZ r-rod Doorfaces N -�d- wrightsoft® Duct System Summary o. Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772466-6796 Emil: QUICKCALCS@AOL.COM Project Information For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowestfidion rate Actual airflow Total efective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1160 cfm 0 ft Supply Branch Detail Table Cooling 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1160 clim Name Design (Btuh) Htg (cfm) Clg (dm) Design FIR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 Ox0 ShMt 0 0 BEDROOM c 2788 119 126 0 0 Ox0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM -A c 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox 0 ShMt 0 0 GREATIDINING C 2855 108 129 0 0 OxO ShMt 0 0 GREATDINING-A C 2855 108 129 0 0 OXO ShMt 0 0 GREATIDINING-B c 2855 108 129 0 0 OXO ShMt 0 0 KrrCHEN c 725 31 33 0 0 OxO ShMt 0 0 LAUNDRY h 520 48 23 0 0 OxO ShMt 0 0 M. BATH h 811 49 37 0 0 Ox 0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 RDOro7 c 2167 92 98 0 0 Ox 0 ShMt 0 0 WIC c 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (CIM) TEL (ft) Design FIR Veloc (fpm) Diam (in) HxW (in) Stud/Joist Opening (in) Dud Mall Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 ShMt 40- wrightsoft® 2021Jarv1213:18:19 I—:_- NgfSLite'Ja Ud�ml20l9l9.021 RSU08101 /� ...Do rMWri tbhft HVACIWYNNE-THEWINDSO Pagel g Rnp CaIc=MIB Fror¢Doorfaces: N