Loading...
HomeMy WebLinkAboutProduct Approval I , S� RECEIVED ' I NOV j2 2029 PAk �. tlnq®apartment E EXTR M E M ETAUt.suchC006tY FABRICATORS SKILLED CRAFTERS OF METAL ROOFING SYSTEMS 26ga ( min ) VMAX over 15/32 ( min ) p1ywpl.?dCopy Extreme Metal Fabricators -- x- 2120 SW Poma Dr I Palm City FL 34990 FOR Product Description FEVI NC 5V Crimp style exposed fastener panel with 24 m00[�s�eC n I rib height of 3/8 . ST, LUCIE CON" Product Material socc 26ga (min) steel I RECEIVED Corrosion resistant per FBC 1507.4.3 where required Fastener NOV 12 ^P7 11 #9 or #10 x 1.5 fastener with sealing washerSt.Lucie Cour Compliant with FBC 1506.6 where required. Substrate/Deck 15/32 (min) plywood or 3/4 (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 www.TimberLakeCove.com 'V 11 ` David E Eng No.81377 020.10.oi 00.08:33+01'00- Q •• STATE OF ((� /ONAI IE��.. signedThis item has been digitally sealedand . date indicated, Printed copies AX •• • • •• • . . • • be Crimpverified on any electronic copies Exposed • I I I � F �17022.Q�1-FZ8 Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope: Comply with local building code or FBC 1507.4.2 where required. ' Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Maximum Allowable Loads & Installation Requirements: Method A: #9 x 1.5 fastener in 12 -12 pattern at 16 o.c.: 86 PSF Method B: #10 x 05 fastener in It -it pattern at f6 o.c.: 93.5 PSF Method C: #10 x 1.9' fastener in 12' -12' pattern at 8' o.c.: 101 PSF Method D: #10 x 1.f fastener in 12' -1T pattern at b' o.c.: 228 PSF A factor of safety"of 2 has been applied. " Technical Documentation: This product has been tested to the UL 580 standard by Architectural Testing (now Intertek Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in FL 17022.01-R7 i Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables arel based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers forlproject specific approval by local authorities having jurisdiction. Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The some entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC! 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Installation shall be subject to the local building code and authority having jurisdiction; this report shall not be construed to supersede local codes in force. I I EXTREMEMErALFABRICA TORS • I I Instructions: Select the appropriate load table that applies to the structure in question. 2 2 3 Determine the design wind speed for the project location. 2 1: 1 2 Use the attachment method indicated for that 2 windspeed within each roof zone. 2 3 a 12 1 2 2 3 a NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables below, the worst case was taken 2 for each zone and reported using the standard zones 2 2 1-2-3: Zone 1 includes zones 1 and 1' a 3. I Zone 2 includes zones 2e, 2r, and 2n F�]aL HIP ROOF GABLE ROOF -�+aL Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple &+0%OF LEAST HO=AlTAL...E"9'a-0-,""°"EE"LS SMALLER B"'NOT LESS THAN EITHER A%OF LEAST HORQOHTAL OWENSIDH OR Y7 N.W1 scheme, at the expense of some design efficiency. OR AS OETERMNED BY DESBRI OR OTHER APPMABLE DODE. Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING or consult a licensed design professional. METHOD A: METHOD B: METHOD C: METHOD D: #9 AT 16"O.C. #10 AT 16"O.C. #10 AT 8"O.C. #10 AT 6"O.C. I r- 12"(NOM) 12" (NOM) NR: NOT;RATED. CONSULT DESIGN PROFESSIONAL AS NEEDED Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are.located in B,C,or D exposure area Have either a flat roof,or gable/hip roof with max slope of 12:12 Have either a flat roof,or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL17022.01: 26 a 5V Crimp on 15/32" Plywood FL17022.01: 26 a 5V,Crim on 15/32" Plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130: 140 150 160 170 180 190 200 Zone 1: A A A A A _-A A A A A A, Zone 1: 'A ;A' A A A A A D D D Zone 2: A A A A A A A A C, D D Zone 2: A A A A D D D D I® D Zone 3: A A A A_: A A B C;;D ID D Zone 3: A A A WO D _D © D ®i D Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof less than 7°,hip roof with Have either a flat roof less than 70,hip roof with max slope of 12:12,or gable roof with slope between 4.4:12&12:12 max slope of 12:12,or gable roof with slope between 4.4:12&12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL17022.01: 26 a 5V Crimp on 15/32" Plywood FL17022.01: 26 a 5V-Crimp on 15/32" Plywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130' 140 150 160 170 180 190 200 Zone 1: A A A_ A A A A A AAA Zone 1: A A A A A A A ' Zone 2: A A A , A A A A A. , A i B .�.0 Zone 2: A_ ' A A A A r_.. Zone 3: A A A A A . A A B ® D ® Zone 3: -'A p A A F=B D D D D D ® D //oRs' 3 • - •