HomeMy WebLinkAboutDESIGN PRESSURE ' s
TORM
License itCRC 15 5
License#CCsC15198t980t
4047 Okeechobee Blvd,Ste 106,
Beach,FL
SMART hone(561)229 833409
of Southeast Florida
Pro ert Information Building Information
Owner: Susan Steurer-Hesch Wind Zone: 160 MPH.
Address: 1202 NW Winters Creek Rd Exposure Category: D
Palm City,FL 34990 Minimum Building Dimension: 4 ft.
Mean Roof Height: 22 ft.
jet Risk Category: 11
Design Pressure Calculations
Opening Location ]=De�vice Device Device Max Positive Max Negative
Number Zone n} Height(in) Elevation (ft) Pressure(psfl Pressure(Psf)
I Int 136 201 16.75 35.1 -38.8
2 Iitt 301.125 150 12.5 33.7 -37.4
3 Int 298 152 12.67 33.7 -37.4
Prepared in accordance wirh:ASCF 7-l6.Chapter 30.Wind Leads-Components and Cladding.7rh Mirion(2020)Fiarida Building Code.
Page 1 of 1