HomeMy WebLinkAboutAPPROVED 3330.2100281.0000 - Tarpon Flats Lot 1 digi November 3, 2021 Phoenix Custom Homes, LLC Attn: Ms. Fran Donza 1760 N Job Road, Suite 120 West Palm Beach, FL 33411 Re: Letter for Foundation Soil Density and Bearing Capability Tarpon Flats – Lot 1 Lot 1, SW of Bonita Isle Drive & A1A, Port St. Lucie FL UES Project No. 3330.2100281.0000 Dear Ms. Donza: Universal Engineering Sciences (UES) (Formerly GFA) performed one (1) cone penetrometer test (CPT) soundings advanced to an approximate depth of 15 feet below ground surface at the above referenced property. The location of the boring is illustrated on the attached Test Location Plan. The subsurface exploration activities were performed in accordance with Chapter 18 of the 20 20 Florida Building Code, Seventh Edition and applicable ASTM standards. Detailed information for the subsurface conditions encountered in the boring is contained on the attached auger boring log. Based on the test results, the soils upon which the referenced structure will be founded are capable of providing a maximum allowable bearing capacity of 2,500 pounds per square foot (psf) subject to the limitations noted herein. We recommend that the footings bear at a depth of at least 12 inches below finish grade measured from the lowest adjacent grade. We also recommend a minimum footing width of 18 inches for spread footings and 16 inches for monolithic footings, but not less than 8 inches more than the width of the imposed wall. This report does not state or imply that the foundation soils at the bearing level will remain in the same condition in which they were found during the subsurface exploration activities. Exposure to the environment may weaken the foundation soils at the bearing level if the foundation excavations remain open for an extended period, or if the soils become saturated from rainfall. Therefore, UES recommends that the excavations for wall and column footings be performed to final design grade and foundation concrete be placed as soon as practicable to reduce the potential for deterioration of the bearing soils. The geology of the site as mapped on the USDA Soil Survey website consists of Canaveral fine sand, 0 to 5 percent slopes (10). These are sandy soils and organic soils are not indicated. In addition, no unsuitable bearing materials were observed in the borehole, and only normal site preparation should be required for construction. It is recommended that the 2 feet of soils below existing grade, below the bottom of all new footing excavations and slabs, and all fill material be compacted to at least 95 percent of the modified Proctor (ASTM D 1557) maximum dry density prior to placement of concrete for the footings. Proposed One- or Two-Story Residence November 3, 2021 Lot 1, Tarpon Flats, Port St. Lucie, Florida Page 2 UES Project No. 3330.2000281.0000 We appreciate the opportunity to be of service to you on this project and look forward to a continued association. Please contact the undersigned if you have any questions or comments, or if we may further assist you as your plans proceed. UES appreciates the opportunity to assist you during this phase of the project. Please contact us if you have any questions or require additional information. Respectfully Submitted, Universal Engineering Sciences Florida Registry No. 4930 This item has been digitally signed and sealed by Allan G. Abubakar, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Allan G. Abubakar, P.E. Erik Soderstrom, E.I. Sr. Project Engineer Geotechnical Dept. Manager Florida Registration No. 69952 Test Location Plan Tarpon Flats – Lot 1 SW of Bonita Isle Drive & A1A, Fort Pierce, Florida Project No. 3330.2100281.0000 Drafted by: JR Reviewed By: AA Date: 12/31/2013 N CPT -1 Legend Approximate CPT Location Client:Date:12/31/2013 Project No.:3330.2100281.0000 Project: Field Crew:PM/RL Rig ID:OshKoshLocation: Page:1 of 1 Elevation: P P+S Depth 15 30 4.4 0.2 0.66 50 60 100 2.6 0.4 1.31 90 110 180 0.4 0.6 1.97 35 40 70 2.3 0.8 2.62 8 20 16 6.6 1.0 3.28 19 27 38 4.5 1.2 3.94 55 68 110 1.8 1.4 4.59 50 65 100 2.2 1.6 5.25 45 62 90 1.5 1.8 5.91 65 75 130 1.5 2.0 6.56 55 70 110 2.0 2.2 7.22 48 65 96 1.4 2.4 7.87 65 75 130 1.2 2.6 8.53 58 70 116 2.0 2.8 9.19 45 63 90 0.9 3.0 9.84 52 58 104 1.3 3.2 10.50 60 70 120 1.1 3.4 11.15 60 70 120 1.1 3.6 11.81 50 60 100 0.9 3.8 12.47 38 45 76 1.7 4.0 13.12 35 45 70 1.5 4.2 13.78 52 60 104 2.5 4.4 14.44 70 90 140 1.4 4.6 15.09 65 80 130 2.5 4.8 15.75 55 80 110 2.4 5.0 16.40 100 120 200 1.3 5.2 17.06 120 140 240 1.1 5.4 17.72 180 200 360 0.4 5.6 18.37 240 250 480 ##### 5.8 19.03 250 REF ######6.0 19.69 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Field Data qc (tsf)FR Depth (meters) Phoenix Custom Homes, LLC Tarpon Flats - Lot 1, St. Lucie County, FL CPT - Lot 1 Back N27.50676° W80.30787° Existing Grade (At time of exploration) Universal Engineering Sciences 607 NW Commodity Cove, PORT ST. LUCIE, FLORIDA 34986 PHONE: (772) 924-3575 - FAX: (772) 924-3580 CONE PENETRATION SOUNDING (ASTM D 3441) 0 5 10 15 20 25 30 35 40 0 40 80 120 160 200 240 280 320 Cone Bearing, qc (tsf)Depth (feet)02468 Friction Ratio, FR